1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
1438
1439
1440
1441
1442
1443
1444
1445
1446
1447
1448
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490
1491
1492
1493
1494
1495
1496
1497
1498
1499
1500
1501
1502
1503
1504
1505
1506
1507
1508
1509
1510
1511
1512
1513
1514
1515
1516
1517
1518
1519
1520
1521
1522
1523
1524
1525
1526
1527
1528
1529
1530
1531
1532
1533
1534
1535
1536
1537
1538
1539
1540
1541
1542
1543
1544
1545
1546
1547
1548
1549
1550
1551
1552
1553
1554
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569
1570
1571
1572
1573
1574
1575
1576
1577
1578
1579
1580
1581
1582
1583
1584
1585
1586
1587
1588
1589
1590
1591
1592
1593
1594
1595
1596
1597
1598
1599
1600
1601
1602
1603
1604
1605
1606
1607
1608
1609
1610
1611
1612
1613
1614
1615
1616
1617
1618
1619
1620
1621
1622
1623
1624
1625
1626
1627
1628
1629
1630
1631
1632
1633
1634
1635
1636
1637
1638
1639
1640
1641
1642
1643
1644
1645
1646
1647
1648
1649
1650
1651
1652
1653
1654
1655
1656
1657
1658
1659
1660
1661
1662
1663
1664
1665
1666
1667
1668
1669
1670
1671
1672
1673
1674
1675
1676
1677
1678
1679
1680
1681
1682
1683
1684
1685
1686
1687
1688
1689
1690
1691
1692
1693
1694
1695
1696
1697
1698
1699
1700
1701
1702
1703
1704
1705
1706
1707
1708
1709
1710
1711
1712
1713
1714
1715
1716
1717
1718
1719
1720
1721
1722
1723
1724
1725
1726
1727
1728
1729
1730
1731
1732
1733
1734
1735
1736
1737
1738
1739
1740
1741
1742
1743
1744
1745
1746
1747
1748
1749
1750
1751
1752
1753
1754
1755
1756
1757
1758
1759
1760
1761
1762
1763
1764
1765
1766
1767
1768
1769
1770
1771
1772
1773
1774
1775
1776
1777
1778
1779
1780
1781
1782
1783
1784
1785
1786
1787
1788
1789
1790
1791
1792
1793
1794
1795
1796
1797
1798
1799
1800
1801
1802
1803
1804
1805
1806
1807
1808
1809
1810
1811
1812
1813
1814
1815
1816
1817
1818
1819
1820
1821
|
------------------------------------------------------------
-- Emerson Energy Systems (EES)
-- Power MIB
------------------------------------------------------------
EES-POWER-FERRO-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
Integer32, Counter32, enterprises
FROM SNMPv2-SMI
TEXTUAL-CONVENTION, DisplayString, DateAndTime
FROM SNMPv2-TC;
powerMIB MODULE-IDENTITY
LAST-UPDATED "201401060857Z"
ORGANIZATION "
Emerson Energy Systems (EES)"
CONTACT-INFO "
Emerson Energy Systems
141 82 Stockholm
Sweden"
DESCRIPTION "
Emerson Energy Systems (EES) Power MIB, For SMDUH."
::= { enterprises 6302 2 1 }
------------------------------------------------------------
-- Node definitions
------------------------------------------------------------
ees OBJECT IDENTIFIER ::= { enterprises 6302 }
global OBJECT IDENTIFIER ::= { ees 2 }
------------------------------------------------------------
-- Textual conventions
------------------------------------------------------------
Status ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "
This integer value represents the operational or administrative
status of the system. Also used as alarm severity.
Depending on situation there may be limits on allowed values.
Operational values:
(1) unknown - status has not yet been defined
(2) normal - there are no activated alarms
(3) warning - OA, lowest level of 'abnormal' status
(4) minor - A3
(5) major - MA
(6) critical - CA, highest level of 'abnormal' status
Administrative values:
(7) unmanaged
(8) restricted
(9) testing
(10) disabled"
SYNTAX INTEGER {
unknown(1),
normal(2),
warning(3),
minor(4),
major(5),
critical(6),
unmanaged(7),
restricted(8),
testing(9),
disabled(10) }
StatusChange ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "
Indicates 'activated' (1) or 'deactivated' (2) alarm events."
SYNTAX INTEGER {
activated(1),
deactivated(2) }
------------------------------------------------------------
-- 1.1 Identification of the plant { powerMIB 1 }
------------------------------------------------------------
ident OBJECT IDENTIFIER ::= { powerMIB 1 }
identManufacturer OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "
The name of the equipment manufacturer."
::= { ident 1 }
identModel OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "
The manufacturers model designation of the power system."
::= { ident 2 }
identControllerFirmwareVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "
The firmware (software) version of the controller."
::= { ident 3 }
identName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION "
The name of the power plant. This object should be set by
the administrator."
::= { ident 4 }
identSNMPCfgVer OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "
The name of the power plant. This object should be set by
the administrator."
::= { ident 5 }
------------------------------------------------------------
-- 1.2 System values { powerMIB 2 }
------------------------------------------------------------
system OBJECT IDENTIFIER ::= { powerMIB 2 }
systemStatus OBJECT-TYPE
SYNTAX Status
MAX-ACCESS read-only
STATUS current
DESCRIPTION "
Status of the complete plant (highest alarm). One of
(1) unknown - status has not yet been defined
(2) normal - there are no activated alarms
(3) warning - OA, lowest level of 'abnormal' status
(4) minor - A3
(5) major - MA
(6) critical - CA, highest level of 'abnormal' status
(7) unmanaged
(8) restricted
(9) testing
(10) disabled"
::= { system 1 }
systemVoltage OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "
System voltage, stored as mV, including positive or negative
sign. The integer 2147483647 represents invalid value."
::= { system 2 }
systemCurrent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "
System current, stored as mA, including positive or negative
sign. The integer 2147483647 represents invalid value."
::= { system 3 }
systemUsedCapacity OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "
Used capacity, stored as % of the total capacity.
The integer 2147483647 represents invalid value."
::= { system 4 }
-- ------------------------------------------------------------------------
-- 1.2.5. Battery group
-- ------------------------------------------------------------------------
psBattery OBJECT IDENTIFIER ::= { system 5 }
psBatteryVoltage OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Battery voltage, stored as mV, including positive or negative
sign. The integer 2147483647 represents invalid value."
::= { psBattery 1 }
psTotalBatteryCurrent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Battery current, stored as mA, including positive or negative
sign. The integer 2147483647 represents invalid value."
::= { psBattery 2 }
psBatteryCapacity OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "
Calculated capacity, stored as % of the total capacity.
The integer 2147483647 represents invalid value."
::= { psBattery 3 }
psBatteryNominalCapacity OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "
nominal installed capacity, stored as mAh.
The integer 2147483647 represents invalid value."
::= { psBattery 4 }
psBatteryTable OBJECT-TYPE
SYNTAX SEQUENCE OF PSBatteryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Battery Table."
::= { psBattery 5 }
psBatteryEntry OBJECT-TYPE
SYNTAX PSBatteryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Battery Measurement Table Entry."
INDEX { psBatteryIndex }
::= { psBatteryTable 1 }
PSBatteryEntry ::= SEQUENCE {
psBatteryIndex Integer32,
psBatteryCurrent Integer32,
psBatteryName DisplayString
}
psBatteryIndex OBJECT-TYPE
SYNTAX Integer32(1..16777215)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Automatically generated index object."
::= { psBatteryEntry 1 }
psBatteryCurrent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Battery current in Amps."
::= { psBatteryEntry 2 }
psBatteryName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Battery shunt name."
::= { psBatteryEntry 3 }
-- ------------------------------------------------------------------------
-- 1.2.6. the psInput group
-- ------------------------------------------------------------------------
psInput OBJECT IDENTIFIER ::= { system 6 }
psInputLineAVoltage OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The AC line A voltage, stored as mV. The integer 2147483647
represents invalid value."
::= { psInput 1 }
psInputLineBVoltage OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The AC line B voltage, stored as mV. The integer 2147483647
represents invalid value."
::= { psInput 2 }
psInputLineCVoltage OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The AC line C voltage, stored as mV. The integer 2147483647
represents invalid value."
::= { psInput 3 }
-- ------------------------------------------------------------------------
-- 1.2.7. the temperatures
-- ------------------------------------------------------------------------
psTemperature OBJECT IDENTIFIER ::= { system 7 }
psTemperature1 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The first route temperature, stored as 0.001 Celsius degree.
The integer 2147483647 represents invalid value."
::= { psTemperature 1 }
psTemperature2 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The second route temperature, stored as 0.001 Celsius degree.
The integer 2147483647 represents invalid value.."
::= { psTemperature 2 }
psTemperatureTable OBJECT-TYPE
SYNTAX SEQUENCE OF PSTemperatureEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Temperature Measurement Table."
::= { psTemperature 3 }
psTemperatureEntry OBJECT-TYPE
SYNTAX PSTemperatureEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Temperature Measurement Table Entry."
INDEX { psTemperatureIndex }
::= { psTemperatureTable 1 }
PSTemperatureEntry ::= SEQUENCE {
psTemperatureIndex Integer32,
psTemperatureMeasurement Integer32,
psTemperatureName DisplayString,
psTemperatureType INTEGER,
psTemperatureAlarmStatus INTEGER
}
psTemperatureIndex OBJECT-TYPE
SYNTAX Integer32(1..71)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Temperature Probe Number "
::= { psTemperatureEntry 1 }
psTemperatureMeasurement OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Temperature Value In Centigrade."
::= { psTemperatureEntry 2 }
psTemperatureName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Configured Temperature Probe Name."
::= { psTemperatureEntry 3 }
psTemperatureType OBJECT-TYPE
SYNTAX INTEGER {
none(0),
ambient(1),
battery(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Temperature Probe Type "
::= { psTemperatureEntry 4 }
psTemperatureAlarmStatus OBJECT-TYPE
SYNTAX INTEGER {
high(0),
low(1),
fail(2),
none(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Temperature Probe Alarm Status "
::= { psTemperatureEntry 5 }
psStatusCommunication OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
normal(2),
interrupt(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of communication with the Power System. interrupt(3) indicates
some errors occurred between Power System and agent."
::= { system 8 }
psStatusBatteryMode OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
floatCharging(2),
shortTest(3),
bcForTest(4),
manualTesting(5),
planTesting(6),
acFailTesting(7),
acFail(8),
manualBC(9),
autoBC(10),
cyclicBC(11),
masterBC(12),
masterBT(13)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of battery modes,
FloatCharging(2),
ShortTest(3),
BoostChargingForTest(4),
ManualTesting(5),
PlanTesting(6),
ACFailTesting(7),
ACFail(8),
ManualBoostCharging(9),
AutoBoostCharging(10),
CyclicBoostCharging(11),
MasterBoostCharging(12),
MasterBateryTesting(13)."
::= { system 9 }
-- ------------------------------------------------------------------------
-- 1.2.10. the SM series group(only get number of SM series)
-- ------------------------------------------------------------------------
psSMNumber OBJECT IDENTIFIER ::= { system 10 }
psSMACNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of SM AC module."
::= { psSMNumber 1 }
psSMBATNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of SM BAT module."
::= { psSMNumber 2 }
psSMIONumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of SM IO module."
::= { psSMNumber 3 }
-- ------------------------------------------------------------------------
-- 1.2.11. Rectifier group
-- ------------------------------------------------------------------------
psRectifier OBJECT IDENTIFIER ::= { system 11 }
numberOfInstalledRectifiers OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "
number of rectifiers, stored as integer.
The integer 2147483647 represents invalid value."
::= { psRectifier 1 }
numberOfRectifiersCommunicating OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "
number of rectifiers communicating, stored as integer.
The integer 2147483647 represents invalid value."
::= { psRectifier 2 }
rectifiersUsedCapacity OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "
Used capacity, stored as % of the total capacity.
The integer 2147483647 represents invalid value."
::= { psRectifier 3 }
psRectifierTable OBJECT-TYPE
SYNTAX SEQUENCE OF PSRectifierEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "
Table holding information about indivual rectifiers."
::= { psRectifier 4 }
psRectifierEntry OBJECT-TYPE
SYNTAX PSRectifierEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "
An entry (conceptual row) in the rectifierInfoTable."
INDEX { psRectifierIndex }
::= { psRectifierTable 1 }
PSRectifierEntry ::= SEQUENCE {
psRectifierIndex Integer32,
psRectifierProductNumber DisplayString,
psRectifierHWVersion DisplayString,
psRectifierSWVersion DisplayString,
psRectifierSerialNumber DisplayString,
psRectifierCurrent Integer32,
psRectifierIdent DisplayString,
psRectifierFail StatusChange
}
psRectifierIndex OBJECT-TYPE
SYNTAX Integer32(1..16777215)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Automatically generated index object."
::= { psRectifierEntry 1 }
psRectifierProductNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Rectifier Product Number."
::= { psRectifierEntry 2}
psRectifierHWVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Rectifier Hardware Revision."
::= { psRectifierEntry 3}
psRectifierSWVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Rectifier Software Revision."
::= { psRectifierEntry 4}
psRectifierSerialNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Rectifier Serial Number."
::= { psRectifierEntry 5}
psRectifierCurrent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Rectifier Current."
::= { psRectifierEntry 6}
psRectifierIdent OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Rectifier physical location identifier."
::= { psRectifierEntry 7}
psRectifierFail OBJECT-TYPE
SYNTAX StatusChange
MAX-ACCESS read-only
STATUS current
DESCRIPTION "
The type of alarm change. One of
(1) activated
(2) deactivated"
::= { psRectifierEntry 8}
-- ------------------------------------------------------------------------
-- 1.2.12. the Distribution
-- ------------------------------------------------------------------------
psDistribution OBJECT IDENTIFIER ::= { system 12 }
psTotalLoadCurrent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "
Total Load current, stored as integer.
The integer 2147483647 represents invalid value."
::= { psDistribution 1 }
psDistributionLoadTable OBJECT-TYPE
SYNTAX SEQUENCE OF PSDistributionLoadEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Distribution Table."
::= { psDistribution 2 }
psDistributionLoadEntry OBJECT-TYPE
SYNTAX PSDistributionLoadEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Distribution Measurement Table Entry."
INDEX { psDistributionLoadIndex }
::= { psDistributionLoadTable 1 }
PSDistributionLoadEntry ::= SEQUENCE {
psDistributionLoadIndex Integer32,
psDistributionLoadCurrent Integer32,
psDistributionLoadName DisplayString
}
psDistributionLoadIndex OBJECT-TYPE
SYNTAX Integer32(1..268386303)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Automatically generated index object."
::= { psDistributionLoadEntry 1 }
psDistributionLoadCurrent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Distribution current in Amps."
::= { psDistributionLoadEntry 2 }
psDistributionLoadName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Distribution name."
::= { psDistributionLoadEntry 3 }
psDistributionGeneralTable OBJECT-TYPE
SYNTAX SEQUENCE OF PSDistributionGeneralEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Distribution Table."
::= { psDistribution 3 }
psDistributionGeneralEntry OBJECT-TYPE
SYNTAX PSDistributionGeneralEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Distribution Measurement Table Entry."
INDEX { psDistributionGeneralIndex }
::= { psDistributionGeneralTable 1 }
PSDistributionGeneralEntry ::= SEQUENCE {
psDistributionGeneralIndex Integer32,
psDistributionGeneralCurrent Integer32,
psDistributionGeneralName DisplayString
}
psDistributionGeneralIndex OBJECT-TYPE
SYNTAX Integer32(1..268386303)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Automatically generated index object."
::= { psDistributionGeneralEntry 1 }
psDistributionGeneralCurrent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Distribution current in Amps."
::= { psDistributionGeneralEntry 2 }
psDistributionGeneralName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Distribution name."
::= { psDistributionGeneralEntry 3 }
-- ------------------------------------------------------------------------
-- 1.2.13. Converter group
-- ------------------------------------------------------------------------
psConverter OBJECT IDENTIFIER ::= { system 13 }
numberOfInstalledConverters OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "
number of converters, stored as integer.
The integer 2147483647 represents invalid value."
::= { psConverter 1 }
numberOfConvertersCommunicating OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "
number of converters communicating, stored as integer.
The integer 2147483647 represents invalid value."
::= { psConverter 2 }
convertersUsedCapacity OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "
Used capacity, stored as % of the total capacity.
The integer 2147483647 represents invalid value."
::= { psConverter 3 }
psConverterVoltage OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "
Converter voltage in mV.
The integer 2147483647 represents invalid value."
::= { psConverter 4 }
psTotalConverterCurrent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "
Total Converter current in Amps.
The integer 2147483647 represents invalid value."
::= { psConverter 5 }
psConverterTable OBJECT-TYPE
SYNTAX SEQUENCE OF PSConverterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "
Table holding information about indivual converters."
::= { psConverter 6 }
psConverterEntry OBJECT-TYPE
SYNTAX PSConverterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "
An entry (conceptual row) in the ConverterInfoTable."
INDEX { psConverterIndex }
::= { psConverterTable 1 }
PSConverterEntry ::= SEQUENCE {
psConverterIndex Integer32,
psConverterProductNumber DisplayString,
psConverterHWVersion DisplayString,
psConverterSWVersion DisplayString,
psConverterSerialNumber DisplayString,
psConverterCurrent Integer32,
psConverterIdent DisplayString,
psConverterFail StatusChange }
psConverterIndex OBJECT-TYPE
SYNTAX Integer32(1..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Automatically generated index object."
::= { psConverterEntry 1 }
psConverterProductNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Converter Product Number."
::= { psConverterEntry 2}
psConverterHWVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Converter Hardware Revision."
::= { psConverterEntry 3}
psConverterSWVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Converter Software Revision."
::= { psConverterEntry 4}
psConverterSerialNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Converter Serial Number."
::= { psConverterEntry 5}
psConverterCurrent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Converter Current."
::= { psConverterEntry 6}
psConverterIdent OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Converter physical location identifier."
::= { psConverterEntry 7}
psConverterFail OBJECT-TYPE
SYNTAX StatusChange
MAX-ACCESS read-only
STATUS current
DESCRIPTION "
The type of alarm change. One of
(1) activated
(2) deactivated"
::= { psConverterEntry 8}
-- ------------------------------------------------------------------------
-- 1.2.14. Control group
-- ------------------------------------------------------------------------
psControl OBJECT IDENTIFIER ::= { system 14 }
controlBatteryTest OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "
Control battery test, start(1), stop (0)."
::= { psControl 1 }
controlRelay8 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "
Control relay8, close(1), open(0)."
::= { psControl 2 }
controlRelay7 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "
Control relay7, close(1), open(0)."
::= { psControl 3 }
controlRelay6 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "
Control relay6, close(1), open(0)."
::= { psControl 4 }
controlRelayTest OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "
Control Relay test, start(1), stop (0)."
::= { psControl 5 }
-- ------------------------------------------------------------------------
-- 1.2.15. EquipmentSignalTable
-- ------------------------------------------------------------------------
psEquipmentSignalTable OBJECT-TYPE
SYNTAX SEQUENCE OF EquipmentSignalTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "
Table of indexed equipment signal values."
::= { system 15 }
equipmentSignalTableEntry OBJECT-TYPE
SYNTAX EquipmentSignalTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "
An entry (conceptual row) in the psEquipment Signal Table."
INDEX { psEquipmentSignalTableEntryIndex }
::= { psEquipmentSignalTable 1 }
EquipmentSignalTableEntry ::= SEQUENCE {
psEquipmentSignalTableEntryIndex Integer32,
psEquipmentSignalValue Integer32 }
psEquipmentSignalTableEntryIndex OBJECT-TYPE
SYNTAX Integer32(1..268386303)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "
The unique sequence number of this equipment signal."
::= { equipmentSignalTableEntry 1 }
psEquipmentSignalValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "
Indexed equipment signal value."
::= { equipmentSignalTableEntry 2 }
-- ------------------------------------------------------------------------
-- 1.2.16. SMDUHCurrentTable
-- ------------------------------------------------------------------------
psSMDUHCurrent OBJECT IDENTIFIER ::= { system 16 }
numberOfInstalledSMDUH OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "
number of SMDHU units, stored as integer.
The integer 2147483647 represents invalid value."
::= { psSMDUHCurrent 1 }
psSMDUH1Voltage OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "
SMDUH1 Voltage."
::= { psSMDUHCurrent 2 }
psSMDUH2Voltage OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "
SMDUH2 Voltage."
::= { psSMDUHCurrent 3 }
psSMDUH3Voltage OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "
SMDUH3 Voltage."
::= { psSMDUHCurrent 4 }
psSMDUH4Voltage OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "
SMDUH4 Voltage."
::= { psSMDUHCurrent 5 }
psSMDUH5Voltage OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "
SMDUH5 Voltage."
::= { psSMDUHCurrent 6 }
psSMDUH6Voltage OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "
SMDUH6 Voltage."
::= { psSMDUHCurrent 7 }
psSMDUH7Voltage OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "
SMDUH7 Voltage."
::= { psSMDUHCurrent 8 }
psSMDUH8Voltage OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "
SMDU8 Voltage."
::= { psSMDUHCurrent 9 }
psSMDUHCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF PSSMDUHEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "
Table holding information about SMDUH currents."
::= { psSMDUHCurrent 10 }
psSMDUHCurrentEntry OBJECT-TYPE
SYNTAX PSSMDUHEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "
An entry (conceptual row) in the SMDUHTable."
INDEX { psSMDUHCurrentIndex }
::= { psSMDUHCurrentTable 1 }
psSMDUHCurrentEntry ::= SEQUENCE {
psSMDUHCurrentIndex Integer32,
psSMDUHCurrent1 Integer32,
psSMDUHCurrent2 Integer32,
psSMDUHCurrent3 Integer32,
psSMDUHCurrent4 Integer32,
psSMDUHCurrent5 Integer32,
psSMDUHCurrent6 Integer32,
psSMDUHCurrent7 Integer32,
psSMDUHCurrent8 Integer32,
psSMDUHCurrent9 Integer32,
psSMDUHCurrent10 Integer32,
psSMDUHCurrent11 Integer32,
psSMDUHCurrent12 Integer32,
psSMDUHCurrent13 Integer32,
psSMDUHCurrent14 Integer32,
psSMDUHCurrent15 Integer32,
psSMDUHCurrent16 Integer32,
psSMDUHCurrent17 Integer32,
psSMDUHCurrent18 Integer32,
psSMDUHCurrent19 Integer32,
psSMDUHCurrent20 Integer32 }
psSMDUHCurrentIndex OBJECT-TYPE
SYNTAX Integer32(1..64)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Automatically generated index object."
::= { psSMDUHCurrentEntry 1 }
psSMDUHCurrent1 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SMDUH Current 1."
::= { psSMDUHCurrentEntry 2}
psSMDUHCurrent2 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SMDUH Current 2."
::= { psSMDUHCurrentEntry 3}
psSMDUHCurrent3 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SMDUH Current 3."
::= { psSMDUHCurrentEntry 4}
psSMDUHCurrent4 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SMDUH Current 4."
::= { psSMDUHCurrentEntry 5}
psSMDUHCurrent5 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SMDUH Current 5."
::= { psSMDUHCurrentEntry 6}
psSMDUHCurrent6 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SMDUH Current 6."
::= { psSMDUHCurrentEntry 7}
psSMDUHCurrent7 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SMDUH Current 7."
::= { psSMDUHCurrentEntry 8}
psSMDUHCurrent8 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SMDUH Current 8."
::= { psSMDUHCurrentEntry 9}
psSMDUHCurrent9 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SMDUH Current 9."
::= { psSMDUHCurrentEntry 10}
psSMDUHCurrent10 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SMDUH Current 10."
::= { psSMDUHCurrentEntry 11}
psSMDUHCurrent11 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SMDUH Current 11."
::= { psSMDUHCurrentEntry 12}
psSMDUHCurrent12 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SMDUH Current 12."
::= { psSMDUHCurrentEntry 13}
psSMDUHCurrent13 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SMDUH Current 13."
::= { psSMDUHCurrentEntry 14}
psSMDUHCurrent14 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SMDUH Current 14."
::= { psSMDUHCurrentEntry 15}
psSMDUHCurrent15 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SMDUH Current 15."
::= { psSMDUHCurrentEntry 16}
psSMDUHCurrent16 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SMDUH Current 16."
::= { psSMDUHCurrentEntry 17}
psSMDUHCurrent17 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SMDUH Current 17."
::= { psSMDUHCurrentEntry 18}
psSMDUHCurrent18 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SMDUH Current 18."
::= { psSMDUHCurrentEntry 19}
psSMDUHCurrent19 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SMDUH Current 19."
::= { psSMDUHCurrentEntry 20}
psSMDUHCurrent20 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SMDUH Current 20."
::= { psSMDUHCurrentEntry 21}
-- ------------------------------------------------------------------------
-- 1.2.17. SMDUHPowerTable
-- ------------------------------------------------------------------------
psSMDUHPower OBJECT IDENTIFIER ::= { system 17 }
psSMDUHPowerTable OBJECT-TYPE
SYNTAX SEQUENCE OF PSSMDUHEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "
Table holding information about SMDUH power."
::= { psSMDUHPower 1 }
psSMDUHPowerEntry OBJECT-TYPE
SYNTAX PSSMDUHEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "
An entry (conceptual row) in the SMDUHPowerTable."
INDEX { psSMDUHPowerIndex }
::= { psSMDUHPowerTable 1 }
psSMDUHPowerEntry ::= SEQUENCE {
psSMDUHPowerIndex Integer32,
psSMDUHPower1 Integer32,
psSMDUHPower2 Integer32,
psSMDUHPower3 Integer32,
psSMDUHPower4 Integer32,
psSMDUHPower5 Integer32,
psSMDUHPower6 Integer32,
psSMDUHPower7 Integer32,
psSMDUHPower8 Integer32,
psSMDUHPower9 Integer32,
psSMDUHPower10 Integer32,
psSMDUHPower11 Integer32,
psSMDUHPower12 Integer32,
psSMDUHPower13 Integer32,
psSMDUHPower14 Integer32,
psSMDUHPower15 Integer32,
psSMDUHPower16 Integer32,
psSMDUHPower17 Integer32,
psSMDUHPower18 Integer32,
psSMDUHPower19 Integer32,
psSMDUHPower20 Integer32 }
psSMDUHPowerIndex OBJECT-TYPE
SYNTAX Integer32(1..64)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Automatically generated index object."
::= { psSMDUHPowerEntry 1 }
psSMDUHPower1 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SMDUH Power 1."
::= { psSMDUHPowerEntry 2}
psSMDUHPower2 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SMDUH Power 2."
::= { psSMDUHPowerEntry 3}
psSMDUHPower3 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SMDUH Power 3."
::= { psSMDUHPowerEntry 4}
psSMDUHPower4 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SMDUH Power 4."
::= { psSMDUHPowerEntry 5}
psSMDUHPower5 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SMDUH Power 5."
::= { psSMDUHPowerEntry 6}
psSMDUHPower6 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SMDUH Power 6."
::= { psSMDUHPowerEntry 7}
psSMDUHPower7 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SMDUH Power 7."
::= { psSMDUHPowerEntry 8}
psSMDUHPower8 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SMDUH Power 8."
::= { psSMDUHPowerEntry 9}
psSMDUHPower9 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SMDUH Power 9."
::= { psSMDUHPowerEntry 10}
psSMDUHPower10 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SMDUH Power 10."
::= { psSMDUHPowerEntry 11}
psSMDUHPower11 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SMDUH Power 11."
::= { psSMDUHPowerEntry 12}
psSMDUHPower12 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SMDUH Power 12."
::= { psSMDUHPowerEntry 13}
psSMDUHPower13 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SMDUH Power 13."
::= { psSMDUHPowerEntry 14}
psSMDUHPower14 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SMDUH Power 14."
::= { psSMDUHPowerEntry 15}
psSMDUHPower15 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SMDUH Power 15."
::= { psSMDUHPowerEntry 16}
psSMDUHPower16 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SMDUH Power 16."
::= { psSMDUHPowerEntry 17}
psSMDUHPower17 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SMDUH Power 17."
::= { psSMDUHPowerEntry 18}
psSMDUHPower18 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SMDUH Power 18."
::= { psSMDUHPowerEntry 19}
psSMDUHPower19 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SMDUH Power 19."
::= { psSMDUHPowerEntry 20}
psSMDUHPower20 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SMDUH Power 20."
::= { psSMDUHPowerEntry 21}
-- ------------------------------------------------------------------------
-- 1.2.18. SMDUHEnergyTable
-- ------------------------------------------------------------------------
psSMDUHEnergy OBJECT IDENTIFIER ::= { system 18 }
psSMDUHEnergyTable OBJECT-TYPE
SYNTAX SEQUENCE OF PSSMDUHEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "
Table holding information about SMDUH energy counters."
::= { psSMDUHEnergy 1 }
psSMDUHEnergyEntry OBJECT-TYPE
SYNTAX PSSMDUHEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "
An entry (conceptual row) in the SMDUHEnergyTable."
INDEX { psSMDUHEnergyIndex }
::= { psSMDUHEnergyTable 1 }
psSMDUHEnergyEntry ::= SEQUENCE {
psSMDUHEnergyIndex Integer32,
psSMDUHTotalEnergy1 Integer32,
psSMDUHTotalEnergy2 Integer32,
psSMDUHTotalEnergy3 Integer32,
psSMDUHTotalEnergy4 Integer32,
psSMDUHTotalEnergy5 Integer32,
psSMDUHTotalEnergy6 Integer32,
psSMDUHTotalEnergy7 Integer32,
psSMDUHTotalEnergy8 Integer32,
psSMDUHTotalEnergy9 Integer32,
psSMDUHTotalEnergy10 Integer32,
psSMDUHTotalEnergy11 Integer32,
psSMDUHTotalEnergy12 Integer32,
psSMDUHTotalEnergy13 Integer32,
psSMDUHTotalEnergy14 Integer32,
psSMDUHTotalEnergy15 Integer32,
psSMDUHTotalEnergy16 Integer32,
psSMDUHTotalEnergy17 Integer32,
psSMDUHTotalEnergy18 Integer32,
psSMDUHTotalEnergy19 Integer32,
psSMDUHTotalEnergy20 Integer32 }
psSMDUHEnergyIndex OBJECT-TYPE
SYNTAX Integer32(1..64)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Automatically generated index object."
::= { psSMDUHEnergyEntry 1 }
psSMDUHTotalEnergy1 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SMDUH Total Energy 1."
::= { psSMDUHEnergyEntry 2}
psSMDUHTotalEnergy2 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SMDUH Total Energy 2."
::= { psSMDUHEnergyEntry 3}
psSMDUHTotalEnergy3 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SMDUH Total Energy 3."
::= { psSMDUHEnergyEntry 4}
psSMDUHTotalEnergy4 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SMDUH Total Energy 4."
::= { psSMDUHEnergyEntry 5}
psSMDUHTotalEnergy5 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SMDUH Total Energy 5."
::= { psSMDUHEnergyEntry 6}
psSMDUHTotalEnergy6 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SMDUH Total Energy 6."
::= { psSMDUHEnergyEntry 7}
psSMDUHTotalEnergy7 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SMDUH Total Energy 7."
::= { psSMDUHEnergyEntry 8}
psSMDUHTotalEnergy8 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SMDUH Total Energy 8."
::= { psSMDUHEnergyEntry 9}
psSMDUHTotalEnergy9 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SMDUH Total Energy 9."
::= { psSMDUHEnergyEntry 10}
psSMDUHTotalEnergy10 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SMDUH Total Energy 10."
::= { psSMDUHEnergyEntry 11}
psSMDUHTotalEnergy11 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SMDUH Total Energy 11."
::= { psSMDUHEnergyEntry 12}
psSMDUHTotalEnergy12 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SMDUH Total Energy 12."
::= { psSMDUHEnergyEntry 13}
psSMDUHTotalEnergy13 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SMDUH Total Energy 13."
::= { psSMDUHEnergyEntry 14}
psSMDUHTotalEnergy14 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SMDUH Total Energy 14."
::= { psSMDUHEnergyEntry 15}
psSMDUHTotalEnergy15 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SMDUH Total Energy 15."
::= { psSMDUHEnergyEntry 16}
psSMDUHTotalEnergy16 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SMDUH Total Energy 16."
::= { psSMDUHEnergyEntry 17}
psSMDUHTotalEnergy17 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SMDUH Total Energy 17."
::= { psSMDUHEnergyEntry 18}
psSMDUHTotalEnergy18 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SMDUH Total Energy 18."
::= { psSMDUHEnergyEntry 19}
psSMDUHTotalEnergy19 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SMDUH Total Energy 19."
::= { psSMDUHEnergyEntry 20}
psSMDUHTotalEnergy20 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SMDUH Total Energy 20."
::= { psSMDUHEnergyEntry 21}
------------------------------------------------------------
-- Alarm trap counter { powerMIB 3 }
------------------------------------------------------------
alarmLastTrapNo OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "
The sequence number of last submitted alarm trap,
also last row in alarmTrapTable."
::= { powerMIB 3 }
------------------------------------------------------------
-- Active Alarm table { powerMIB 4 }
------------------------------------------------------------
alarmActiveAlarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF ActiveAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "
Table holding information about the currently active alarms."
::= { powerMIB 4 }
activeAlarmEntry OBJECT-TYPE
SYNTAX ActiveAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "
An entry (conceptual row) in the alarmTrapTable."
INDEX { alarmIndex }
::= { alarmActiveAlarmTable 1 }
ActiveAlarmEntry ::= SEQUENCE {
alarmIndex Counter32,
alarmTime DateAndTime,
alarmStatusChange StatusChange,
alarmSeverity Status,
alarmDescription DisplayString,
alarmType Integer32 }
alarmIndex OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "
The unique sequence number of this alarm trap."
::= { activeAlarmEntry 1 }
alarmTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "
Date and time when event occured (local time), including
timezone if supported by controller."
::= { activeAlarmEntry 2 }
alarmStatusChange OBJECT-TYPE
SYNTAX StatusChange
MAX-ACCESS read-only
STATUS current
DESCRIPTION "
The type of alarm change. One of
(1) activated
(2) deactivated"
::= { activeAlarmEntry 3 }
alarmSeverity OBJECT-TYPE
SYNTAX Status
MAX-ACCESS read-only
STATUS current
DESCRIPTION "
The severity of the alarm. One of
(3) warning - OA, lowest level of alarm severity
(4) minor - A3
(5) major - MA
(6) critical - CA, highest level of alarm severity"
::= { activeAlarmEntry 4 }
alarmDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "
Free-text description of alarm."
::= { activeAlarmEntry 5 }
alarmType OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "
Alarm type, i.e. an integer specifying the type of alarm."
::= { activeAlarmEntry 6 }
------------------------------------------------------------
-- Events/traps { powerMIB 5 }
------------------------------------------------------------
powerEvents OBJECT IDENTIFIER ::= { powerMIB 5 }
alarmTrap NOTIFICATION-TYPE
OBJECTS {
alarmIndex,
alarmTime,
alarmStatusChange,
alarmSeverity,
alarmDescription,
alarmType }
STATUS current
DESCRIPTION "
An alarm trap is sent when an alarm occurs (activated) or
returns to normal state (deactivated). Alarm traps are logged
in alarmTrapTable. Variables in this trap:
* alarmIndex - The unique sequence number of this alarm trap.
* alarmTime - Date and time when event occured (local time),
including timezone if supported by controller.
* alarmStatusChange - (1) activated or (2) deactivated.
* alarmSeverity - Integer describing the severity of the alarm.
* alarmDescription - Free-text description of alarm.
* alarmType - Integer indicating type of alarm."
::= { powerEvents 1 }
alarmActiveTrap NOTIFICATION-TYPE
OBJECTS {
alarmTime,
alarmSeverity,
alarmDescription,
alarmType }
STATUS current
DESCRIPTION "
An alarm trap is sent when an alarm occurs (activated)
Variables in this trap
* alarmTime - Date and time when event occured (local time),
including timezone if supported by controller.
* alarmSeverity - Integer describing the severity of the alarm.
* alarmDescription - Free-text description of alarm.
* alarmType - Integer indicating type of alarm."
::= { powerEvents 2 }
alarmCeaseTrap NOTIFICATION-TYPE
OBJECTS {
alarmTime,
alarmSeverity,
alarmDescription,
alarmType }
STATUS current
DESCRIPTION "
An alarm trap is sent when an alarm returns to normal state (clear, deactivated).
Variables in this trap:
* alarmTime - Date and time when event occured (local time),
including timezone if supported by controller.
* alarmSeverity - Integer describing the severity of the alarm.
* alarmDescription - Free-text description of alarm.
* alarmType - Integer indicating type of alarm."
::= { powerEvents 3 }
------------------------------------------------------------
-- End of MIB definitions
------------------------------------------------------------
END
|