1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
|
--
-- sle-mpls-tp-pro-if-mib.mib
-- MIB generated by MG-SOFT Visual MIB Builder Version 6.0 Build 88
-- Tuesday, January 12, 2016 at 14:08:09
--
SLE-MPLS-TP-PRO-IF-MIB DEFINITIONS ::= BEGIN
IMPORTS
sleMgmt
FROM DASAN-SMI
mplsTunnelIndex, mplsTunnelInstance, mplsTunnelIngressLSRId, mplsTunnelEgressLSRId
FROM MPLS-TE-STD-MIB
SleControlStatusType, SleControlRequestResultType
FROM SLE-TC-MIB
zeroDotZero, TimeTicks, IpAddress, Unsigned32, Gauge32,
OBJECT-TYPE, MODULE-IDENTITY, OBJECT-IDENTITY
FROM SNMPv2-SMI;
sleMplsTpNode MODULE-IDENTITY
LAST-UPDATED "201510070000Z" -- October 07, 2015 at 00:00 GMT
ORGANIZATION
"Multiprotocol Label Switching (MPLS) Working Group"
CONTACT-INFO
"Gyerok Kwon
Dasan Networks
Email: grkwon@dasannetworks.com
Kantharaj B M
Dasan Networks
Email: kanth@dasannetworks.com
DongChel Shin (Chris)
Dasan Networks
Email: dchshin@dasannetworks.com
Comments about this document should be emailed
directly to the Dasan support email ID at
support@dasannetworks.com."
DESCRIPTION
"Copyright (c) 2012 IETF Trust and the persons identified
as the document authors. All rights reserved.
This MIB module contains generic object definitions for
MPLS Traffic Engineering in transport networks."
REVISION "201207150000Z" -- July 15, 2012 at 00:00 GMT
DESCRIPTION
"MPLS_TP node configuration table"
::= { sleMpls 13 }
--
-- Node definitions
--
sleMpls OBJECT-IDENTITY
STATUS current
DESCRIPTION
"SLE MPLS."
::= { sleMgmt 16 }
sleMplsTpProIf OBJECT IDENTIFIER ::= { sleMplsTpNode 2 }
sleMplsTpProIfInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleMplsTpProIfInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION " "
::= { sleMplsTpProIf 1 }
sleMplsTpProIfInfoEntry OBJECT-TYPE
SYNTAX SleMplsTpProIfInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION " "
INDEX { sleMplsTPProIfInfoIfIndex }
::= { sleMplsTpProIfInfoTable 1 }
SleMplsTpProIfInfoEntry ::=
SEQUENCE {
sleMplsTPProIfInfoIfIndex
Unsigned32,
sleMplsTPProIfInfoIpAddr
IpAddress
}
sleMplsTPProIfInfoIfIndex OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object is used in accommodating the bigger
size Global_Node_ID and/or ICC with lower size LSR
identifier in order to index the mplsTunnelTable.
The Local Identifier is configured between 1 and 16777215,
as valid IP address range starts from 16777216(01.00.00.00).
This range is chosen to identify the mplsTunnelTable's
Ingress/Egress LSR-id is IP address or Local identifier,
if the configured range is not IP address, administrator is
expected to retrieve the complete information
(Global_Node_ID or ICC) from mplsTunnelExtNodeConfigTable.
This way, existing mplsTunnelTable is reused for
bidirectional tunnel extensions for MPLS based transport networks.
This Local Identifier allows the administrator to assign
a unique identifier to map Global_Node_ID and/or ICC."
::= { sleMplsTpProIfInfoEntry 1 }
sleMplsTPProIfInfoIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION " "
::= { sleMplsTpProIfInfoEntry 2 }
sleMplsTpProIfControl OBJECT IDENTIFIER ::= { sleMplsTpProIf 2 }
sleMplsTpProIfControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
setMplsTpProIfIpAddr(1),
unSetMplsTpProIfIpAddr(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object holds the possible read-write columns that
can be modified in the TunnelExtNodeConfigTable table.
For each read-write column of TunnelExtNodeConfigTable table,
a Set Operation control value is added in this object."
::= { sleMplsTpProIfControl 1 }
sleMplsTpProIfControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object displays the status of the configuration done."
::= { sleMplsTpProIfControl 2 }
sleMplsTpProIfControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is based on the SLE style where a timer is configured for every control table."
::= { sleMplsTpProIfControl 3 }
sleMplsTpProIfControlTimestamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the time at which the configuration is done."
::= { sleMplsTpProIfControl 4 }
sleMplsTpProIfControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The standard result of the SET operation is stored here."
::= { sleMplsTpProIfControl 5 }
sleMplsTpProIfControlIfIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION " "
::= { sleMplsTpProIfControl 6 }
sleMplsTpProIfControlIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Global Operator Identifier."
REFERENCE
"MPLS-TP Identifiers [RFC6370]."
::= { sleMplsTpProIfControl 7 }
END
--
-- sle-mpls-tp-pro-if-mib.mib
--
|