summaryrefslogtreecommitdiff
path: root/MIBS/dasan/SLE-MPLS-TP-NODE-MIB
blob: 88eab815df0a2287c65744e692e60ffcefa8e35b (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
--
-- sle-mpls-tp-node-mib.mib
-- MIB generated by MG-SOFT Visual MIB Builder Version 6.0  Build 88
-- Tuesday, January 12, 2016 at 11:22:02
--

	SLE-MPLS-TP-NODE-MIB DEFINITIONS ::= BEGIN
 
		IMPORTS
			sleMgmt			
				FROM DASAN-SMI			
			MplsCcId, MplsIccId			
				FROM MPLS-TC-EXT-STD-MIB			
			mplsTunnelIndex, mplsTunnelInstance, mplsTunnelIngressLSRId, mplsTunnelEgressLSRId			
				FROM MPLS-TE-STD-MIB			
			SleControlStatusType, SleControlRequestResultType			
				FROM SLE-TC-MIB			
			zeroDotZero, TimeTicks, IpAddress, Unsigned32, Gauge32, 
			OBJECT-TYPE, MODULE-IDENTITY, OBJECT-IDENTITY			
				FROM SNMPv2-SMI;
	
	
		sleMplsTpNode MODULE-IDENTITY 
			LAST-UPDATED "201510070000Z"		-- October 07, 2015 at 00:00 GMT
			ORGANIZATION 
				"Multiprotocol Label Switching (MPLS) Working Group"
			CONTACT-INFO 
				"Gyerok Kwon 
				Dasan Networks
				Email:  grkwon@dasannetworks.com
				
				Kantharaj B M
				Dasan Networks
				Email:  kanth@dasannetworks.com
				
				DongChel Shin (Chris)
				Dasan Networks
				Email:  dchshin@dasannetworks.com
				
				Comments about this document should be emailed
				directly to the Dasan support email ID at
				support@dasannetworks.com."
			DESCRIPTION 
				"Copyright (c) 2012 IETF Trust and the persons identified
				as the document authors.  All rights reserved.
				
				This MIB module contains generic object definitions for
				MPLS Traffic Engineering in transport networks."
			REVISION "201207150000Z"		-- July 15, 2012 at 00:00 GMT
			DESCRIPTION 
				"MPLS_TP node configuration table"
			::= { sleMpls 13 }

		
	
	
--
-- Node definitions
--
	
		sleMpls OBJECT-IDENTITY
			STATUS current
			DESCRIPTION 
				"SLE MPLS."
			::= { sleMgmt 16 }

		
		sleMplsTpNodeCfg OBJECT IDENTIFIER ::= { sleMplsTpNode 1 }

		
		sleMplsTpNodeCfgInfo OBJECT IDENTIFIER ::= { sleMplsTpNodeCfg 1 }

		
		sleMplsTpNodeCfgInfoGlobalId OBJECT-TYPE
			SYNTAX Unsigned32 (1..4294967295)
			MAX-ACCESS read-only
			STATUS current
			DESCRIPTION
				"This object indicates the Global Operator Identifier.
				this object value should be zero when
				sleMplsTpNodeConfigInfoCcId and  sleMplsTpNodeConfigInfoICcId
				is configured with non-null value."
			REFERENCE
				"MPLS-TP Identifiers [RFC6370]."
			::= { sleMplsTpNodeCfgInfo 1 }

		
		sleMplsTpNodeCfgInfoItutCc OBJECT-TYPE
			SYNTAX MplsCcId
			MAX-ACCESS read-only
			STATUS current
			DESCRIPTION
				"This object allows the operator or service provider to
				configure a unique MPLS-TP ITU-T Carrier Code (ICC)
				either for Ingress ID or Egress ID.
				
				This object value should be zero when 
				sleMplsTpNodeConfigInfoGlobalId are assigned with non-zero value."
			REFERENCE
				"MPLS-TP Identifiers [RFC6370]."
			::= { sleMplsTpNodeCfgInfo 2 }

		
		sleMplsTpNodeCfgInfoItutIcc OBJECT-TYPE
			SYNTAX MplsIccId
			MAX-ACCESS read-only
			STATUS current
			DESCRIPTION
				"This object allows the operator or service provider to
				configure a unique MPLS-TP ITU-T Carrier Code (ICC)
				either for Ingress ID or Egress ID.
				
				This object value should be zero when
				sleMplsTpNodeConfigInfoGlobalId are assigned with non-zero value."
			REFERENCE
				"MPLS-TP Identifiers [RFC6370]."
			::= { sleMplsTpNodeCfgInfo 3 }

		
		sleMplsTpNodeCfgInfoNodeId OBJECT-TYPE
			SYNTAX IpAddress
			MAX-ACCESS read-only
			STATUS current
			DESCRIPTION
				"This object indicates the Node_ID within the operator."
			REFERENCE
				"MPLS-TP Identifiers [RFC6370]."
			::= { sleMplsTpNodeCfgInfo 4 }

		
		sleMplsTpNodeCfgInfoNodeType OBJECT-TYPE
			SYNTAX INTEGER
				{
				ietf(1),
				itut(2)
				}
			MAX-ACCESS read-only
			STATUS current
			DESCRIPTION
				"This object value should be zero when 
				sleMplsTpNodeConfigInfoGlobalId are assigned with non-zero value ."
			::= { sleMplsTpNodeCfgInfo 5 }

		
		sleMplsTpNodeCfgControl OBJECT IDENTIFIER ::= { sleMplsTpNodeCfg 2 }

		
		sleMplsTpNodeCfgControlRequest OBJECT-TYPE
			SYNTAX INTEGER
				{
				setMplsTpNode(1),
				unsetMplsTpNode(2)
				}
			MAX-ACCESS read-write
			STATUS current
			DESCRIPTION
				"This object holds the possible read-write columns that can be 
				modified in the TunnelExtNodeConfigTable table. For each read-write 
				column of TunnelExtNodeConfigTable table, a Set Operation control 
				value is added in this object."
			::= { sleMplsTpNodeCfgControl 1 }

		
		sleMplsTpNodeCfgControlStatus OBJECT-TYPE
			SYNTAX SleControlStatusType
			MAX-ACCESS read-only
			STATUS current
			DESCRIPTION
				"This object displays the status of the configuration done."
			::= { sleMplsTpNodeCfgControl 2 }

		
		sleMplsTpNodeCfgControlTimer OBJECT-TYPE
			SYNTAX Gauge32
			MAX-ACCESS read-write
			STATUS current
			DESCRIPTION
				"This object is based on the SLE style where a timer is configured
				for every control table."
			::= { sleMplsTpNodeCfgControl 3 }

		
		sleMplsTpNodeCfgControlTimestamp OBJECT-TYPE
			SYNTAX TimeTicks
			MAX-ACCESS read-only
			STATUS current
			DESCRIPTION
				"This object specifies the time at which the configuration is done."
			::= { sleMplsTpNodeCfgControl 4 }

		
		sleMplsTpNodeCfgControlReqResult OBJECT-TYPE
			SYNTAX SleControlRequestResultType
			MAX-ACCESS read-only
			STATUS current
			DESCRIPTION
				"The standard result of the SET operation is stored here."
			::= { sleMplsTpNodeCfgControl 5 }

		
		sleMplsTpNodeCfgControlGlobalId OBJECT-TYPE
			SYNTAX Unsigned32 (1..4294967295)
			MAX-ACCESS read-write
			STATUS current
			DESCRIPTION
				"This object indicates the Global Operator Identifier.
				This object value should be zero when 
				sleMplsTpNodeConfigControlIccId  and sleMplsTpNodeConfigControlccId
				is configured with non-null value."
			REFERENCE
				"MPLS-TP Identifiers [RFC6370]."
			::= { sleMplsTpNodeCfgControl 6 }

		
		sleMplsTpNodeCfgControlItutCc OBJECT-TYPE
			SYNTAX MplsCcId
			MAX-ACCESS read-write
			STATUS current
			DESCRIPTION
				"This object allows the operator or service provider to
				configure a unique MPLS-TP ITU-T Carrier Code (ICC)
				either for Ingress ID or Egress ID.
				
				This object value should be zero when 
				sleMplsTpNodeConfigControlGlobalId are assigned with 
				non-zero value."
			REFERENCE
				"MPLS-TP Identifiers [RFC6370]."
			::= { sleMplsTpNodeCfgControl 7 }

		
		sleMplsTpNodeCfgControlItutIcc OBJECT-TYPE
			SYNTAX MplsIccId
			MAX-ACCESS read-write
			STATUS current
			DESCRIPTION
				"This object allows the operator or service provider to configure a 
				unique MPLS-TP ITU-T Carrier Code (ICC) either for Ingress ID 
				or Egress ID.
				
				This object value should be zero when
				sleMplsTpNodeConfigControlGlobalId are assigned with non-zero
				value."
			REFERENCE
				"MPLS-TP Identifiers [RFC6370]."
			::= { sleMplsTpNodeCfgControl 8 }

		
		sleMplsTpNodeCfgControlNodeId OBJECT-TYPE
			SYNTAX IpAddress
			MAX-ACCESS read-write
			STATUS current
			DESCRIPTION
				"This object indicates the Node_ID within the operator."
			REFERENCE
				"MPLS-TP Identifiers [RFC6370]."
			::= { sleMplsTpNodeCfgControl 9 }

		
		sleMplsTpNodeCfgControlNodeType OBJECT-TYPE
			SYNTAX INTEGER
				{
				ietf(1),
				itut(2)
				}
			MAX-ACCESS read-write
			STATUS current
			DESCRIPTION
				"This object allows the operator or service provider to
				configure a unique MPLS-TP ITU-T Carrier Code (ICC)
				either for Ingress ID or Egress ID.
				
				This object value should be zero when
				msleMplsTpNodeConfigControlGlobalId are assigned with non-zero
				value."
			REFERENCE
				"MPLS-TP Identifiers [RFC6370]."
			::= { sleMplsTpNodeCfgControl 10 }

		
	
	END

--
-- sle-mpls-tp-node-mib.mib
--