1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
|
--==============================================================================
-- Copyright (c) 2004-2014 New H3C Tech. Co., Ltd. All rights reserved.
--
-- Description: PPP Over Sonet MIB
-- Reference:
-- Version: V1.5
-- History:
-- V1.0 2004-10-28 created by fuzhenyu
-- V1.1 2004-12-13 add notifications(9-13) under hh3cPosMIBNotifications by fuzhenyu.
-- V1.2 2005-04-12 add hh3cPosFlagJ0Type, hh3cPosFlagJ1Type in hh3cPosParamTable by zhaotingqi.
-- V1.3 2007-07-19 add hh3cPosNormalAlarm in hh3cPosMIBNotifications by chenfangchun
-- V1.4 2010-05-19 modified by Tong Wei for TCA (Threshold Crossing Alarms)
-- add hh3cPosB1TCAThreshold, hh3cPosB2TCAThreshold, hh3cPosB3TCAThreshold,
-- hh3cPosB1TCAEnable, hh3cPosB2TCAEnable and hh3cPosB3TCAEnable
-- in hh3cPosParamTable
-- add hh3cPosB1TCAlarm, hh3cPosB2TCAlarm and hh3cPosB3TCAlarm
-- in hh3cPosMIBNotifications
-- V1.5 2013-10-10 modify hh3cPosEncapsulation and hh3cPosMTU
-- in hh3cPosParamTable by chenzhouhui.
-- V1.6 2016-09-09 modify hh3cPosEncapsulation in hh3cPosParamTable by zhengwei.
--==============================================================================
HH3C-PPP-OVER-SONET-MIB DEFINITIONS ::= BEGIN
IMPORTS
ifIndex, ifDescr
FROM IF-MIB
Counter64, Integer32, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE
FROM SNMPv2-SMI
DisplayString, TruthValue
FROM SNMPv2-TC
hh3cCommon
FROM HH3C-OID-MIB;
hh3cPos MODULE-IDENTITY
LAST-UPDATED "201609091700Z" -- Sep 09, 2016 GMT
ORGANIZATION
"New H3C Tech. Co., Ltd."
CONTACT-INFO
"Platform Team New H3C Tech. Co., Ltd.
Hai-Dian District Beijing P.R. China
http://www.h3c.com
Zip:100085"
DESCRIPTION
"This MIB manages POS(PPP Over Sonet)interfaces by providing
an operational table which controls parameters of each POS
interface and reports alarm conditions.
"
REVISION "201609091700Z" -- Sep 09, 2016 at 17:00 GMT
DESCRIPTION "Update the version of this MIB module"
REVISION "201310101700Z" -- Oct 10, 2013 at 17:00 GMT
DESCRIPTION "Update the version of this MIB module"
REVISION "201005191700Z" -- May 19, 2010 at 17:00 GMT
DESCRIPTION "Update the version of this MIB module"
REVISION "200707191700Z" -- Jul 19, 2007 at 17:00 GMT
DESCRIPTION "The initial version of this MIB module"
::= { hh3cCommon 19 }
hh3cPosMIBObjects OBJECT IDENTIFIER ::= { hh3cPos 1 }
hh3cPosParamTable OBJECT-TYPE
SYNTAX SEQUENCE OF Hh3cPosParamTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The pos parameter table."
::= { hh3cPosMIBObjects 1 }
hh3cPosParamTableEntry OBJECT-TYPE
SYNTAX Hh3cPosParamTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The entry of pos table."
INDEX
{
ifIndex
}
::= { hh3cPosParamTable 1 }
Hh3cPosParamTableEntry ::= SEQUENCE
{
hh3cPosCRC INTEGER,
hh3cPosMTU Integer32,
hh3cPosScramble TruthValue,
hh3cPosClockSource INTEGER,
hh3cPosSdhFlagJ0 DisplayString,
hh3cPosSdhFlagJ1 DisplayString,
hh3cPosSonetFlagJ0 Integer32,
hh3cPosSonetFlagJ1 DisplayString,
hh3cPosFlagC2 Integer32,
hh3cPosFrameType INTEGER,
hh3cPosBindVlanId Integer32,
hh3cPosEncapsulation INTEGER,
hh3cPoskeepaliveTimeout Integer32,
hh3cPosBERthresholdSF Integer32,
hh3cPosBERthresholdSD Integer32,
hh3cPosB1Error Counter64,
hh3cPosB2Error Counter64,
hh3cPosB3Error Counter64,
hh3cPosM1Error Counter64,
hh3cPosG1Error Counter64,
hh3cPosFlagJ0Type INTEGER,
hh3cPosFlagJ1Type INTEGER,
hh3cPosB1TCAThreshold Integer32,
hh3cPosB2TCAThreshold Integer32,
hh3cPosB3TCAThreshold Integer32,
hh3cPosB1TCAEnable INTEGER,
hh3cPosB2TCAEnable INTEGER,
hh3cPosB3TCAEnable INTEGER
}
hh3cPosCRC OBJECT-TYPE
SYNTAX INTEGER{crc32(1),crc16(2)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The length of CRC"
DEFVAL { crc32 }
::={ hh3cPosParamTableEntry 1 }
hh3cPosMTU OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Maximum Transfer Unit (MTU) of POS interface"
::={ hh3cPosParamTableEntry 2 }
hh3cPosScramble OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Scrambling is used to avoid continuous 0 or 1 in signals. This
object is to decide whether to scramble or not"
DEFVAL { true }
::={ hh3cPosParamTableEntry 3 }
hh3cPosClockSource OBJECT-TYPE
SYNTAX INTEGER{system(1),line(2)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value indicates the source of clock signal. System indicates
that clock signals are from device itself and line for clock signals
from remote"
DEFVAL { line }
::={ hh3cPosParamTableEntry 4 }
hh3cPosSdhFlagJ0 OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..15))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The section trace byte. This node is used when the frame type is sdh."
::={ hh3cPosParamTableEntry 5 }
hh3cPosSdhFlagJ1 OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..15))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The path trace byte. This node is used when the frame type is sdh."
::={ hh3cPosParamTableEntry 6 }
hh3cPosSonetFlagJ0 OBJECT-TYPE
SYNTAX Integer32(0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The section trace byte. This node is used when the frame type is sonet."
::={ hh3cPosParamTableEntry 7 }
hh3cPosSonetFlagJ1 OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..62))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The path trace byte. This node is used when the frame type is sonet."
::={ hh3cPosParamTableEntry 8 }
hh3cPosFlagC2 OBJECT-TYPE
SYNTAX Integer32(0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The parameter for the channel signal value of C2 byte"
DEFVAL { 22 }
::={ hh3cPosParamTableEntry 9 }
hh3cPosFrameType OBJECT-TYPE
SYNTAX INTEGER{sdh(1),sonet(2)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The frame type that encapsulates the packet. Default frame type is
sdh(Synchronous Digital Hierarchy) It also can be configured using
sonet type(Synchronous Optical Network)."
DEFVAL { sdh }
::={ hh3cPosParamTableEntry 10 }
hh3cPosBindVlanId OBJECT-TYPE
SYNTAX Integer32(0..4095)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The vlan that this pos port binds. The vlan can not include any other
port, otherwise error will be returned. If the vlan has a virtual
interface, the status of virtual interface will be up or down according
to the link status or this pos."
::={ hh3cPosParamTableEntry 11 }
hh3cPosEncapsulation OBJECT-TYPE
SYNTAX INTEGER{ppp(1),hdlc(2),fr(3),mfr(4)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The type of encapsulation "
DEFVAL { ppp }
::={ hh3cPosParamTableEntry 12 }
hh3cPoskeepaliveTimeout OBJECT-TYPE
SYNTAX Integer32(0..32767)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The keeplive of ppp, hdlc, fr or mfr. It is the query interval of link status. Two
members of a link should have same keeplive. The default 0 prohibits
detecting status of link."
::={ hh3cPosParamTableEntry 13 }
hh3cPosBERthresholdSF OBJECT-TYPE
SYNTAX Integer32(3..9)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The bit-error rate threshold for Signal Fault. SF threshold should
be greater than SD threshold."
DEFVAL { 3 }
::={ hh3cPosParamTableEntry 14 }
hh3cPosBERthresholdSD OBJECT-TYPE
SYNTAX Integer32(3..9)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The bit-error rate threshold for Signal Degrade. SD threshold should
be less than SF threshold."
DEFVAL { 6 }
::={ hh3cPosParamTableEntry 15 }
hh3cPosB1Error OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Counter for SBIPE(Section Bit Interleave Parity Error)"
::={ hh3cPosParamTableEntry 16 }
hh3cPosB2Error OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Counter for LBIPE(Line Bit Interleave Parity Error)"
::={ hh3cPosParamTableEntry 17 }
hh3cPosB3Error OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Counter for PBIPE(Path Bit Interleave Parity Error)"
::={ hh3cPosParamTableEntry 18 }
hh3cPosM1Error OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"How many times does LREI(Line Remote Error Indication) occur"
::={ hh3cPosParamTableEntry 19 }
hh3cPosG1Error OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"How many times does PREI(Path Remote Error Indication) occur"
::={ hh3cPosParamTableEntry 20 }
hh3cPosFlagJ0Type OBJECT-TYPE
SYNTAX INTEGER{sdh(1),sonet(2)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The frame type that encapsulates the flag J0. Default frame type is
sdh(Synchronous Digital Hierarchy). It also can be configured using
sonet(Synchronous Optical Network) type."
DEFVAL { sdh }
::={ hh3cPosParamTableEntry 21 }
hh3cPosFlagJ1Type OBJECT-TYPE
SYNTAX INTEGER{sdh(1),sonet(2)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The frame type that encapsulates the flag J1. Default frame type is
sdh(Synchronous Digital Hierarchy). It also can be configured using
sonet(Synchronous Optical Network) type."
DEFVAL { sdh }
::={ hh3cPosParamTableEntry 22 }
hh3cPosB1TCAThreshold OBJECT-TYPE
SYNTAX Integer32 (3..9)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Threshold for B1 TCA."
DEFVAL { 6 }
::={ hh3cPosParamTableEntry 23 }
hh3cPosB2TCAThreshold OBJECT-TYPE
SYNTAX Integer32 (3..9)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Threshold for B2 TCA."
DEFVAL { 6 }
::={ hh3cPosParamTableEntry 24 }
hh3cPosB3TCAThreshold OBJECT-TYPE
SYNTAX Integer32 (3..9)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Threshold for B3 TCA."
DEFVAL { 6 }
::={ hh3cPosParamTableEntry 25 }
hh3cPosB1TCAEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable traps of B1 TCA."
DEFVAL { enable }
::={ hh3cPosParamTableEntry 26 }
hh3cPosB2TCAEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable traps of B2 TCA."
DEFVAL { enable }
::={ hh3cPosParamTableEntry 27 }
hh3cPosB3TCAEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable traps of B3 TCA."
DEFVAL { enable }
::={ hh3cPosParamTableEntry 28 }
hh3cPosMIBNotificationsPrefix OBJECT IDENTIFIER ::= { hh3cPos 2 }
hh3cPosMIBNotifications OBJECT IDENTIFIER ::= { hh3cPosMIBNotificationsPrefix 0 }
hh3cPosLOSAlarm NOTIFICATION-TYPE
OBJECTS
{
ifIndex
}
STATUS current
DESCRIPTION
"Alarm indicates loss of signal"
::={ hh3cPosMIBNotifications 1 }
hh3cPosLOFAlarm NOTIFICATION-TYPE
OBJECTS
{
ifIndex
}
STATUS current
DESCRIPTION
"Alarm indicates loss of frame"
::={ hh3cPosMIBNotifications 2 }
hh3cPosOOFAlarm NOTIFICATION-TYPE
OBJECTS
{
ifIndex
}
STATUS current
DESCRIPTION
"Alarm indicates out of frame"
::={ hh3cPosMIBNotifications 3 }
hh3cPosLAISAlarm NOTIFICATION-TYPE
OBJECTS
{
ifIndex
}
STATUS current
DESCRIPTION
"Alarm when LAIS(Line Alarm Indication Signal) arrives"
::={ hh3cPosMIBNotifications 4 }
hh3cPosLRDIAlarm NOTIFICATION-TYPE
OBJECTS
{
ifIndex
}
STATUS current
DESCRIPTION
"Alarm when LRDI(Line Remote Defect Indication) arrives"
::={ hh3cPosMIBNotifications 5 }
hh3cPosPRDIAlarm NOTIFICATION-TYPE
OBJECTS
{
ifIndex
}
STATUS current
DESCRIPTION
"Alarm when PRDI(Path Remote Defect Indication) arrives"
::={ hh3cPosMIBNotifications 6 }
hh3cPosPAISAlarm NOTIFICATION-TYPE
OBJECTS
{
ifIndex
}
STATUS current
DESCRIPTION
"Alarm when PAIS(Path Alarm Indication Signal) arrives"
::={ hh3cPosMIBNotifications 7 }
hh3cPosLOPAlarm NOTIFICATION-TYPE
OBJECTS
{
ifIndex
}
STATUS current
DESCRIPTION
"Alarm indicates loss of pointer"
::={ hh3cPosMIBNotifications 8 }
hh3cPosSTIMAlarm NOTIFICATION-TYPE
OBJECTS
{
ifIndex
}
STATUS current
DESCRIPTION
"Alarm indicates inconsistency between sent and received J0 bytes."
::={ hh3cPosMIBNotifications 9 }
hh3cPosPTIMAlarm NOTIFICATION-TYPE
OBJECTS
{
ifIndex
}
STATUS current
DESCRIPTION
"Alarm indicates inconsistency between sent and received J1 bytes."
::={ hh3cPosMIBNotifications 10 }
hh3cPosPSLMAlarm NOTIFICATION-TYPE
OBJECTS
{
ifIndex
}
STATUS current
DESCRIPTION
"Alarm indicates a mismatched C2 byte."
::={ hh3cPosMIBNotifications 11 }
hh3cPosLSDAlarm NOTIFICATION-TYPE
OBJECTS
{
ifIndex
}
STATUS current
DESCRIPTION
"Alarm indicates that the B2 bit-error rate exceeds SD threshold."
::={ hh3cPosMIBNotifications 12 }
hh3cPosLSFAlarm NOTIFICATION-TYPE
OBJECTS
{
ifIndex
}
STATUS current
DESCRIPTION
"Alarm indicates that the B2 bit-error rate exceeds SF threshold."
::={ hh3cPosMIBNotifications 13 }
hh3cPosNormalAlarm NOTIFICATION-TYPE
OBJECTS
{
ifIndex
}
STATUS current
DESCRIPTION
"Alarm indicates that the Pos interface state returns normal."
::={ hh3cPosMIBNotifications 14 }
hh3cPosB1TCAlarm NOTIFICATION-TYPE
OBJECTS { ifIndex, ifDescr }
STATUS current
DESCRIPTION
"Threshold crossing alarms for B1."
::={ hh3cPosMIBNotifications 15 }
hh3cPosB2TCAlarm NOTIFICATION-TYPE
OBJECTS { ifIndex, ifDescr }
STATUS current
DESCRIPTION
"Threshold crossing alarms for B2."
::={ hh3cPosMIBNotifications 16 }
hh3cPosB3TCAlarm NOTIFICATION-TYPE
OBJECTS { ifIndex, ifDescr }
STATUS current
DESCRIPTION
"Threshold crossing alarms for B3."
::={ hh3cPosMIBNotifications 17 }
END
|