1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
|
--**************************************************************************
--
-- Copyright 2010 Scientific Atlanta, A Cisco Company
-- All Rights Reserved
-- No portions of this material may be reproduced in any
-- form without the written permission of:
-- Scientific Atlanta, A Cisco Company
-- 5030 Sugarloaf Pkwy
-- Lawrenceville, Georgia 30044
--
--**************************************************************************
SA-MTA-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE,
enterprises,
Integer32,
Unsigned32
FROM SNMPv2-SMI
ifIndex
FROM IF-MIB
SnmpAdminString
FROM SNMP-FRAMEWORK-MIB
TruthValue,
DateAndTime
FROM SNMPv2-TC ;
sa OBJECT IDENTIFIER ::= { enterprises 1429 }
saVoip OBJECT IDENTIFIER ::= { sa 78 }
saMta MODULE-IDENTITY
LAST-UPDATED "201611100000Z"
ORGANIZATION "Cisco Inc."
CONTACT-INFO "vveeraga@cisco.com"
DESCRIPTION
"saMtaDevLCSSignalingSupport controls the LCS Signaling."
-- History
REVISION "201611100000Z"
DESCRIPTION
"Initial release of reduced-set module for releases based on BFC 5.7.x."
::= { saVoip 3 }
-- MTA Device
saMtaDevice OBJECT IDENTIFIER ::= { saMta 1 }
saMtaDevOffHookWarnTOBusy OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object configures whether an endpoint should ring off-hook warning tone.
When this feature is disabled(0), Endpoint should ring off-hook warning tone.
When this feature is enabled(1), Endpoint should ring busy tone instead of off-hook warning tone.
The default value of this object is disabled(0)."
DEFVAL { 0 }
::= { saMtaDevice 61 }
-- ==========================
-- ENDPOINT TABLE STARTS HERE
-- ==========================
saMtaEndPointTable OBJECT-TYPE
SYNTAX SEQUENCE OF SaMtaEndPointEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table describes the MTA EndPoint
Volume configuration. "
::= { saMta 2 }
saMtaEndPointEntry OBJECT-TYPE
SYNTAX SaMtaEndPointEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" List of attributes for a single MTA endpoint interface."
INDEX { ifIndex }
::= { saMtaEndPointTable 1 }
SaMtaEndPointEntry ::= SEQUENCE {
saMtaEndPntHookFlashMinTime INTEGER,
saMtaEndPntHookFlashMaxTime INTEGER,
saMtaEndPntStatePhysical INTEGER,
saMtaEndPntStateLogical INTEGER
}
saMtaEndPntHookFlashMinTime OBJECT-TYPE
SYNTAX INTEGER (40..2000)
UNITS "milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Shortest onhook time at which hook-flash event will be detected, in miliseconds.
Breaks in loop current with shorter duration are assumed to be noise and are ignored."
::= { saMtaEndPointEntry 1 }
saMtaEndPntHookFlashMaxTime OBJECT-TYPE
SYNTAX INTEGER (100..2000)
UNITS "milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Longest onhook time at which hook-flash event will be detected,
in miliseconds. If onhook time is longer then saMtaHookFlashMaxTime,
hang up event will be detected."
::= { saMtaEndPointEntry 2 }
saMtaEndPntStatePhysical OBJECT-TYPE
SYNTAX INTEGER {
onHook(1),
offHook(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns the physical state of the end point.
1: No phones attached or one or more phones are attached and
on-hook
2: One or more phones are attached and off-hook"
::= { saMtaEndPointEntry 6 }
saMtaEndPntStateLogical OBJECT-TYPE
SYNTAX INTEGER {
connectedIdle(1),
disconnected(2),
inCallVoice(3),
inCallData(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns the logical state of the end point.
1: endpoint is connected to CMS and not in call
2: endpoint is not connected to CMS
3: endpoint is in voice mode call
4: endpoint is in data mode (fax/modem) call"
::= { saMtaEndPointEntry 7 }