summaryrefslogtreecommitdiff
path: root/MIBS/cisco/CISCOSB-EVENTS-MIB
blob: 26032a0cccb38c288581fb8dcfa84353ee1cbd5d (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
CISCOSB-EVENTS-MIB DEFINITIONS ::= BEGIN


IMPORTS
    MODULE-IDENTITY, OBJECT-TYPE                       FROM SNMPv2-SMI
    TEXTUAL-CONVENTION, DisplayString,
    TruthValue, RowStatus                              FROM SNMPv2-TC
    switch001                                          FROM CISCOSB-MIB
    Counter                                            FROM RFC1155-SMI
    InterfaceIndex, InterfaceIndexOrZero               FROM IF-MIB
    SnmpAdminString                                    FROM SNMP-FRAMEWORK-MIB
    RlSmartPortsMacroNameOrZero FROM CISCOSB-SMARTPORTS-MIB;

rlEventsMib MODULE-IDENTITY
        LAST-UPDATED "201009110000Z"
        ORGANIZATION "Cisco Systems, Inc."

        CONTACT-INFO
        "Postal: 170 West Tasman Drive
        San Jose , CA 95134-1706
        USA

        
        Website:  Cisco Small Business Support Community <http://www.cisco.com/go/smallbizsupport>"

        DESCRIPTION
                "MTS events MIB."
        REVISION "201009110000Z"
        DESCRIPTION
                "Initial revision."
    ::= { switch001 150 }

--
-- rlEvents MIB
--

SmartPortType ::= TEXTUAL-CONVENTION
    STATUS current
    DESCRIPTION
        "Supported smart port types."
    SYNTAX  INTEGER {
        unknown(1),
        default(2),
        printer(3),
        desktop(4),
        guest(5),
        server(6),
        host(7),
        ip-camera(8),
        ip-phone(9),
        ip-phone-desktop(10),
        switch(11),
        router(12),
        ap(13)
}
SmartPortMacroParameterName ::= TEXTUAL-CONVENTION
    STATUS current
    DESCRIPTION
        "Smart macro parameter name."
    SYNTAX  DisplayString(SIZE(1..32))

SmartPortMacroParameterValue ::= TEXTUAL-CONVENTION
    STATUS current
    DESCRIPTION
        "Smart macro parameter value."
    SYNTAX  DisplayString(SIZE(1..80))

SmartPortMacroType ::= TEXTUAL-CONVENTION
    STATUS current
    DESCRIPTION
        "Smart macro type - built-in or user-defined."
    SYNTAX  INTEGER {built-in(1), user-defined(2)}

SmartPortMacroParameterOrder ::= TEXTUAL-CONVENTION
    STATUS current
    DESCRIPTION
        "Smart macro parameter order."
    SYNTAX  INTEGER {single(1),  first(2), middle(3), last(4)}

    rlPortEvents OBJECT IDENTIFIER ::= { rlEventsMib 1}

    rlAutoSmartPortAdminStatus OBJECT-TYPE
       SYNTAX  INTEGER {
           enabled  (1),
           disabled (2),
           controlled(3)
       }
       MAX-ACCESS  read-write
       STATUS      current
       DESCRIPTION
           "disabled    - Auto Smart port feature is administratively disabled.
            enabled     - Auto Smart port feature is administratively enabled.
            controlled  - Auto Smart port feature is administratively controlled by VOICE VLAN.
             "
       DEFVAL {controlled}
    ::= { rlPortEvents 1 }

    rlAutoSmartPortOperStatus OBJECT-TYPE
       SYNTAX  INTEGER {
           enabled  (1),
           disabled (2)
       }
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
           "disabled    - Auto Smart port feature is operationally disabled.
            enabled     - Auto Smart port feature is operationally enabled.
             "
       DEFVAL {disabled}
    ::= { rlPortEvents 2 }

    rlAutoSmartPortLastVoiceVlanStatus OBJECT-TYPE
       SYNTAX  INTEGER {
           enabled  (1),
           disabled (2)
       }
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
           "Indicated last status set by VOICE VLAN feature.
            If rlAutoSmartPortAdminStatus has 'controlled' value then the value of this object is the same as rlAutoSmartPortOperStatus.

            enabled   - Auto Smart port feature should be operationally enabled, if rlAutoSmartPortAdminStatus has 'controlled' value.
            disabled  - Auto Smart port feature should be operationally disabled, if rlAutoSmartPortAdminStatus has 'controlled' value
             "
       DEFVAL {disabled}
    ::= { rlPortEvents 3}

    rlAutoSmartPortLastVoiceVlanId OBJECT-TYPE
       SYNTAX  INTEGER
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
           "Indicated last VOICE VLAN ID set by VOICE VLAN feature."
    ::= { rlPortEvents 4}

    rlAutoSmartPortLearningProtocols OBJECT-TYPE
       SYNTAX  BITS {
           cdp  (0),
           lldp (1)
       }
       MAX-ACCESS  read-write
       STATUS      current
       DESCRIPTION
           "cdp  - Information about device type of neighboring devices(s) is learnt
                   via CDP (Cisco Discovery Protocol) advertisements.
            lldp - Information about device type of neighboring devices(s) is learnt
                    via LLDP (Link Layer Discovery Protocol ) advertisements. "
    ::= { rlPortEvents 5 }


     rlAutoSmartPortTypesTable OBJECT-TYPE
       SYNTAX SEQUENCE OF RlAutoSmartPortTypesEntry
       MAX-ACCESS   not-accessible
       STATUS   current
       DESCRIPTION
          "The table is used to keep all the information related to a specific port type."
    ::=  { rlPortEvents  6 }

    rlAutoSmartPortTypesEntry OBJECT-TYPE
       SYNTAX     RlAutoSmartPortTypesEntry
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
           "An entry (conceptual row) in the rlAutoSmartPortTypesTable."
       INDEX  { rlAutoSmartPortTypesType }
    ::= { rlAutoSmartPortTypesTable 1 }

    RlAutoSmartPortTypesEntry ::= SEQUENCE {
        rlAutoSmartPortTypesType                  SmartPortType,
        rlAutoSmartPortTypeStatus                 INTEGER,
        rlAutoSmartPortMacro                      RlSmartPortsMacroNameOrZero,
        rlAutoSmartPortTypesRevertToDefaultMacro  TruthValue,
        rlAutoSmartPortTypesRevertToDefaultParams TruthValue,
        rlAutoSmartPortTypesBuiltinMacro          SmartPortMacroType


    }

    rlAutoSmartPortTypesType OBJECT-TYPE
        SYNTAX  SmartPortType
        MAX-ACCESS  not-accessible
        STATUS  current
        DESCRIPTION
            "Smart port type."
        ::= { rlAutoSmartPortTypesEntry 1 }

    rlAutoSmartPortTypeStatus OBJECT-TYPE
        SYNTAX  INTEGER { enabled(1), disabled(2), default(3) }
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
            "Smart port type global status. "
        ::= { rlAutoSmartPortTypesEntry 2 }

     rlAutoSmartPortMacro OBJECT-TYPE
        SYNTAX  RlSmartPortsMacroNameOrZero
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
            "Macro to be activated when a port is set to the smart port type indicated
             by rlAutoSmartPortTypesType. The macro whose name is 'no_'<rlAutoSmartPortMacro>
             is activated when a port ceases to be of this smart port type. "
        ::= { rlAutoSmartPortTypesEntry 3 }


     rlAutoSmartPortTypesRevertToDefaultMacro OBJECT-TYPE
        SYNTAX  TruthValue
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
            "Setting this object will cause the smart port type macro associated with this smart port type
            to revert to the default macro. "
     ::= { rlAutoSmartPortTypesEntry 4 }

     rlAutoSmartPortTypesRevertToDefaultParams OBJECT-TYPE
        SYNTAX  TruthValue
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
            "Setting this object will cause the default smart port type parameter values associated with the built-in macro
            of this smart port type to revert to their default values."
     ::= { rlAutoSmartPortTypesEntry 5 }

     rlAutoSmartPortTypesBuiltinMacro OBJECT-TYPE
        SYNTAX  SmartPortMacroType
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
            "Indicates whether the macro is built-in or user defined."
     ::= { rlAutoSmartPortTypesEntry 6 }


    rlAutoSmartPortMacrosParamTable OBJECT-TYPE
       SYNTAX SEQUENCE OF RlAutoSmartPortMacrosParamEntry
       MAX-ACCESS   not-accessible
       STATUS   current
       DESCRIPTION
          "The table is used to keep all the default parameter values related to a specific port type."
    ::=  { rlPortEvents  7 }

    rlAutoSmartPortMacrosParamEntry OBJECT-TYPE
       SYNTAX     RlAutoSmartPortMacrosParamEntry
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
           "A parameter name & default value pair for a smart port type macro."
       INDEX  { rlAutoSmartPortTypesType, rlAutoSmartPortMacroType, IMPLIED rlAutoSmartPortMacrosParamName }
    ::= { rlAutoSmartPortMacrosParamTable 1 }

    RlAutoSmartPortMacrosParamEntry ::= SEQUENCE {
        rlAutoSmartPortMacroType        SmartPortMacroType,
        rlAutoSmartPortMacrosParamName  SmartPortMacroParameterName,
        rlAutoSmartPortMacrosParamOrder SmartPortMacroParameterOrder,
        rlAutoSmartPortMacrosParamValue SmartPortMacroParameterValue

    }

      rlAutoSmartPortMacroType OBJECT-TYPE
        SYNTAX  SmartPortMacroType
        MAX-ACCESS  not-accessible
        STATUS  current
        DESCRIPTION
            "Macro type - built-in or user defined."
        ::= { rlAutoSmartPortMacrosParamEntry 1 }

      rlAutoSmartPortMacrosParamName OBJECT-TYPE
        SYNTAX  SmartPortMacroParameterName
        MAX-ACCESS  not-accessible
        STATUS  current
        DESCRIPTION
            "Name of the parameter to be supplied at smart port macro activation. "
        ::= { rlAutoSmartPortMacrosParamEntry 2 }

      rlAutoSmartPortMacrosParamOrder OBJECT-TYPE
        SYNTAX  SmartPortMacroParameterOrder
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
            "Setting this object to 'first' instructs the system to erase all previous information associated
             with the rlAutoSmartPortTypesType and rlAutoSmartPortMacroType associated with this conceptual row.
             Setting this object to 'middle' instructs the system to wait for further parameters.
             Setting this object to 'last' informs the system that no further parameters will be sent and
             therefore it can start the macro or builtin parameters change process.
             Setting this object to 'single' instructs the system to erase all previous information associated
             with the rlAutoSmartPortTypesType and rlAutoSmartPortMacroType associated with this conceptual row and
             informs the system that no further parameters will be sent and therefore it can start macro or builtin
             parameters change process."
        ::= { rlAutoSmartPortMacrosParamEntry 3 }


      rlAutoSmartPortMacrosParamValue OBJECT-TYPE
        SYNTAX  SmartPortMacroParameterValue
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
            "Default value of the parameter to be supplied at smart port macro activation. "
        ::= { rlAutoSmartPortMacrosParamEntry 4 }



     rlAutoSmartPortPortsTable OBJECT-TYPE
       SYNTAX SEQUENCE OF RlAutoSmartPortPortsEntry
       MAX-ACCESS   not-accessible
       STATUS   current
       DESCRIPTION
          "The table is used to keep all the auto smart port information related to a specific port."
    ::=  { rlPortEvents  8 }

    rlAutoSmartPortPortsEntry OBJECT-TYPE
       SYNTAX     RlAutoSmartPortPortsEntry
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
           "An entry (conceptual row) in the rlAutoSmartPortPortsTable."
       INDEX  { rlAutoSmartPortPort }
    ::= { rlAutoSmartPortPortsTable 1 }

    RlAutoSmartPortPortsEntry ::= SEQUENCE {
        rlAutoSmartPortPort                 InterfaceIndex,
        rlAutoSmartPortPortStatus           INTEGER,
        rlAutoSmartPortPortType             SmartPortType,
        rlAutoSmartPortPersistency          INTEGER,
        rlAutoSmartPortLearntPortType       SmartPortType,
        rlAutoSmartPortPortAcquiringType    INTEGER,
        rlAutoSmartPortLastActivatedMacro   RlSmartPortsMacroNameOrZero,
        rlAutoSmartPortFailedCommandNumber  INTEGER,
        rlAutoSmartPortSetLearntPortType   TruthValue


    }

    rlAutoSmartPortPort OBJECT-TYPE
        SYNTAX  InterfaceIndex
        MAX-ACCESS  not-accessible
        STATUS  current
        DESCRIPTION
            "The port to which the smartport information is associated."
        ::= { rlAutoSmartPortPortsEntry 1 }

    rlAutoSmartPortPortStatus OBJECT-TYPE
        SYNTAX  INTEGER {enabled(1), disabled(2)}
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
            "Indicates whether auto smart port feature is enabled or not on this port."
        DEFVAL { enabled }
        ::= { rlAutoSmartPortPortsEntry 2 }

    rlAutoSmartPortPortType OBJECT-TYPE
        SYNTAX  SmartPortType
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
            "Smart port type associated with this port. If set by user, the port will retain
             the smart port type at link down, link not present and reboot events."
        DEFVAL { default }
    ::= { rlAutoSmartPortPortsEntry 3 }


    rlAutoSmartPortPersistency OBJECT-TYPE
        SYNTAX  INTEGER {persistent(1), not-persistent(2)}
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
            "If set to persistent then, if the system concludes, according to
             the information learnt there is no relevant device connected to the port,
             the rlAutoSmartPortPortType will not be changed (as if the user set this
             rlAutoSmartPortPortType himself), except on learning another rlAutoSmartPortPortType."
        DEFVAL { not-persistent }
    ::= { rlAutoSmartPortPortsEntry 4 }


    rlAutoSmartPortLearntPortType OBJECT-TYPE
        SYNTAX  SmartPortType
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
            "Smart port type learnt via the learning protocols. This value will
             be different from rlAutoSmartPortPortType only if rlAutoSmartPortPortType
             was manually configured (i.e. if the value of
             rlAutoSmartPortPortAcquiringType is 'configuration'). The value of the object
             is used to set the value of rlAutoSmartPortPortType
             if the user removes the configuration."
        DEFVAL { default }
        ::= { rlAutoSmartPortPortsEntry 5 }

    rlAutoSmartPortPortAcquiringType OBJECT-TYPE
        SYNTAX  INTEGER {default(1), configuration(2), persistency(3), learning(4)}
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
            "Indicates the way that the value of rlAutoSmartPortPortType was acquired. This object can be
             set only during configuration download."
        ::= { rlAutoSmartPortPortsEntry 6 }

     rlAutoSmartPortLastActivatedMacro OBJECT-TYPE
        SYNTAX  RlSmartPortsMacroNameOrZero
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
            "Indicates macro name of last activated macro or 'no macro' if no macro was run."
     ::= { rlAutoSmartPortPortsEntry 7 }

     rlAutoSmartPortFailedCommandNumber OBJECT-TYPE
        SYNTAX  INTEGER
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
            "Indicates number of command (starting with 1) that caused the macro
             failure or 0 if the macro succeeded or no macro was run."
     ::= { rlAutoSmartPortPortsEntry 8 }

     rlAutoSmartPortSetLearntPortType OBJECT-TYPE
        SYNTAX  TruthValue
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
            "Instructs the system to set the port type to the learnt port type."
     ::= { rlAutoSmartPortPortsEntry 9 }

    rlAutoSmartPortParamsTable OBJECT-TYPE
       SYNTAX SEQUENCE OF RlAutoSmartPortActionParamsEntry
       MAX-ACCESS   not-accessible
       STATUS   current
       DESCRIPTION
          "This table optionally determines the parameter values for the macro that is activated when the smartport type is
           manually changed for a specific port or trunk via the rlAutoSmartPortPortType object."
    ::=  { rlPortEvents  9 }

    rlAutoSmartPortParamsEntry OBJECT-TYPE
       SYNTAX     RlAutoSmartPortActionParamsEntry
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
           "A parameter name & immediate value."
       INDEX  { rlAutoSmartPortIfIndex, IMPLIED rlAutoSmartPortParamName }
    ::= { rlAutoSmartPortParamsTable 1 }

    RlAutoSmartPortActionParamsEntry ::= SEQUENCE {
        rlAutoSmartPortIfIndex    InterfaceIndex,
        rlAutoSmartPortParamName  SmartPortMacroParameterName,
       rlAutoSmartPortParamOrder SmartPortMacroParameterOrder,
        rlAutoSmartPortParamValue SmartPortMacroParameterValue

    }

   rlAutoSmartPortIfIndex OBJECT-TYPE
     SYNTAX  InterfaceIndex
     MAX-ACCESS  not-accessible
     STATUS  current
     DESCRIPTION
         "The port or trunk that this entry is associated with. "
     ::= { rlAutoSmartPortParamsEntry 1 }

   rlAutoSmartPortParamName OBJECT-TYPE
     SYNTAX  SmartPortMacroParameterName
     MAX-ACCESS  not-accessible
     STATUS  current
     DESCRIPTION
         "Name of the parameter whose value must be supplied at a smart port macro activation. "
     ::= { rlAutoSmartPortParamsEntry 2 }

  rlAutoSmartPortParamOrder OBJECT-TYPE
     SYNTAX  SmartPortMacroParameterOrder
     MAX-ACCESS  read-write
     STATUS  current
     DESCRIPTION
            "Setting this object to 'first' instructs the system to erase all previous information associated
             with the rlAutoSmartPortTypesType and rlAutoSmartPortMacroType associated with this conceptual row.
             Setting this object to 'middle' instructs the system to wait for further parameters.
             Setting this object to 'last' informs the system that no further parameters will be sent and
             therefore it can start applying the smartport type.
             Setting this object to 'single' instructs the system to erase all previous information associated
             with the rlAutoSmartPortTypesType and rlAutoSmartPortMacroType associated with this conceptual row and
             informs the system that no further parameters will be sent and informs the system that no further parameters will be sent and
             therefore it can start applying the smartport type."
     ::= { rlAutoSmartPortParamsEntry 3 }

   rlAutoSmartPortParamValue OBJECT-TYPE
     SYNTAX  SmartPortMacroParameterValue
     MAX-ACCESS  not-accessible
     STATUS  current
     DESCRIPTION
         "Value of the parameter whose value must be supplied at a smart port macro activation. "
     ::= { rlAutoSmartPortParamsEntry 4 }



    rlAutoSmartTrunkRefreshTable OBJECT-TYPE
    SYNTAX SEQUENCE OF RlAutoSmartTrunkRefreshEntry
       MAX-ACCESS   not-accessible
       STATUS   current
       DESCRIPTION
           "Setting this object causes running the SmartPort macros of the
           following types: router, switch and ap. This operation is called the trunk refresh operation."
    ::= { rlPortEvents 10 }


    rlAutoSmartTrunkRefreshEntry OBJECT-TYPE
       SYNTAX     RlAutoSmartTrunkRefreshEntry
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
           "An entry (conceptual row) in the rlAutoSmartTrunkRefreshTable."
       INDEX  { rlAutoSmartTrunkRefreshSmartPortType, rlAutoSmartTrunkRefreshIfIndex }
    ::= { rlAutoSmartTrunkRefreshTable 1 }

    RlAutoSmartTrunkRefreshEntry ::= SEQUENCE {
        rlAutoSmartTrunkRefreshSmartPortType  INTEGER,
        rlAutoSmartTrunkRefreshIfIndex        InterfaceIndexOrZero,
        rlAutoSmartTrunkRefreshRowStatus      RowStatus
    }

    rlAutoSmartTrunkRefreshSmartPortType OBJECT-TYPE
        SYNTAX  INTEGER {default(1), switch(11), router(12), ap(13)}
        MAX-ACCESS  not-accessible
        STATUS  current
        DESCRIPTION
            "If not default the trunk refresh operation will be carried out on all ports of this smart port type if
             rlAutoSmartTrunkRefreshIfIndex is nonzero, or on the port specifed by rlAutoSmartTrunkRefreshIfIndex if it's type
             matches the given  this smart port type (if not matching a wrong-value error will be return).
             If default the trunk refresh operation will be carried out on all ports of router, switch and ap smart port type if
             rlAutoSmartTrunkRefreshIfIndex is nonzero, or on the port specifed by rlAutoSmartTrunkRefreshIfIndex."
        ::= { rlAutoSmartTrunkRefreshEntry 1 }

    rlAutoSmartTrunkRefreshIfIndex OBJECT-TYPE
        SYNTAX  InterfaceIndexOrZero
        MAX-ACCESS  not-accessible
        STATUS  current
        DESCRIPTION
            "If 0 the trunk refresh operation will be carried out on all ports of the smart port type as specified in the
             rlAutoSmartTrunkRefreshSmartPortType. If nonzero the trunk refresh operation will be carried out
             on the specified port, if rlAutoSmartTrunkRefreshSmartPortType is default or matches the smart port type of
             the specified port. Any other case will result in a wrong-value error."
        ::= { rlAutoSmartTrunkRefreshEntry 2 }

    rlAutoSmartTrunkRefreshRowStatus OBJECT-TYPE
        SYNTAX  RowStatus
        MAX-ACCESS  read-create
        STATUS  current
        DESCRIPTION
            "Since this an action table only createAndGo will be accepted and the conceptual row will vanish immediately
             after the action execution."
        ::= { rlAutoSmartTrunkRefreshEntry 3 }


       rlAutoSmartBusy OBJECT-TYPE
           SYNTAX  TruthValue
           MAX-ACCESS  read-only
           STATUS      current
           DESCRIPTION
               "If true indicates that the autosmartports system is temporarily busy performing a multiport
                operation and therefore can not service management requests for the time-being."
    ::= { rlPortEvents 11 }