summaryrefslogtreecommitdiff
path: root/MIBS/calix/OCCAM-MLT-MIB
blob: 4d418df94d826cebaa89e3fa249d647107dd97f6 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
1438
1439
1440
1441
1442
1443
1444
1445
1446
1447
1448
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490
1491
1492
1493
1494
1495
1496
1497
1498
1499
1500
1501
1502
1503
1504
1505
1506
1507
1508
1509
1510
1511
1512
1513
1514
1515
1516
1517
1518
1519
1520
1521
1522
1523
1524
1525
1526
1527
1528
1529
1530
1531
1532
1533
1534
1535
1536
1537
1538
1539
1540
1541
1542
1543
1544
1545
1546
1547
1548
1549
1550
1551
1552
1553
1554
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569
1570
1571
1572
1573
1574
1575
1576
1577
1578
1579
1580
1581
1582
1583
1584
1585
1586
1587
1588
1589
1590
1591
1592
1593
1594
1595
1596
1597
1598
1599
1600
1601
1602
1603
1604
1605
1606
1607
1608
1609
1610
1611
1612
1613
1614
1615
1616
1617
1618
1619
1620
1621
1622
1623
1624
1625
1626
1627
1628
1629
1630
1631
1632
1633
1634
1635
1636
1637
1638
1639
1640
1641
1642
1643
1644
1645
1646
1647
1648
1649
1650
1651
1652
1653
1654
1655
1656
1657
1658
1659
1660
1661
1662
1663
1664
1665
1666
1667
1668
1669
1670
1671
1672
1673
1674
1675
1676
1677
1678
1679
1680
1681

OCCAM-MLT-MIB	DEFINITIONS ::= BEGIN
	IMPORTS
		occamGenericMonitorModules
			FROM OCCAM-REG-MODULE
		TEXTUAL-CONVENTION
			FROM SNMPv2-TC
		MODULE-IDENTITY, OBJECT-TYPE, OBJECT-IDENTITY, 
                Integer32, NOTIFICATION-TYPE
			FROM SNMPv2-SMI;
		
	occamMltMib	MODULE-IDENTITY
		LAST-UPDATED	"200104271051Z"
		ORGANIZATION	"Occam Networks"
		CONTACT-INFO	"email support@occamnetworks.com"
		DESCRIPTION
				"This mib module describes objects used 
				to perform Metallic Line Testing on customer	
				access lines and to provide results."
		
		REVISION	"200104271051Z"
		DESCRIPTION	"Reformatted certain text"
	 
		REVISION	"200704170000Z"
		DESCRIPTION	"replace kOhm with Ohm in DC resistance 
                                UNITS"
                
		REVISION	"200702220000Z"
		DESCRIPTION	"remove DISPLAY-HINT"
			 
		REVISION	"200609261000Z"
		DESCRIPTION	"Removed Gr909 from fuse test result names"
			
		REVISION	"200602220135Z"
		DESCRIPTION     "Initial version."
		::=  {  occamGenericMonitorModules  3  }

-- TEXTUAL-CONVENTIONS --

	MltTestType ::= TEXTUAL-CONVENTION 
		STATUS			current
		DESCRIPTION
                        "A selection value for requesting or forcing
                        a test. A requested test will only run if the
                        port is not in use. A forced test will 
                        immediately shut the port and run the test."
		SYNTAX 	                INTEGER  { request ( 1 ) , 
                                        force ( 2 ) } 

	MltTestStatus ::= TEXTUAL-CONVENTION 
		STATUS			current
		DESCRIPTION
			"An indication of test status:
                        none = no test has been requested.
                        mltbusy = another port is currently being tested. 
                        complete = the last requested test has completed.
                        portInUse = the last requested port is in use, 
                        the test was not run. Rerunning the test as 
                        'forced' will shut the port and run the test.
			inProgress = the last requested test is still 
                        running. mltError = the mlt program reported an 
                        error and aborted the test.Check the mltErrorText
                        object.
			mltNotResponding = the mlt program didn't return
                        a result."
		SYNTAX 			INTEGER  { 
                                        none ( 1 ) , 
                                        mltBusy ( 2 ), 
                                        complete ( 3 ) ,
                                        portInUse ( 4 ) , 
                                        inProgress ( 5 ), 
                                        mltError ( 6 ), 
                                        mltNotResponding ( 7 ) }

        MltTestIdentifier ::= TEXTUAL-CONVENTION 
		STATUS			current
		DESCRIPTION
			"An mlt test selection value."
		SYNTAX 			INTEGER  { 
                                        statusSuite ( 1 ) , 
                                        mltSuite ( 2 ) , 
                                        activeModeVoltages ( 3 ) , 
                                        highImpedanceModeVoltages ( 4 ) , 
                                        dcResistance ( 5 ) , 
                                        capacitance ( 6 ) , 
                                        loopDetect ( 7 ) , 
                                        loopLength ( 8 ) } 

	MltTestHookState ::= TEXTUAL-CONVENTION 
		STATUS			current
		DESCRIPTION
			"An mlt test hook state value."
		SYNTAX 			INTEGER  { 
                                        onhook ( 1 ) , 
                                        offhook ( 2 ), 
                                        notAvailable ( 3 ) } 

	MltTestPassFail ::= TEXTUAL-CONVENTION 
		STATUS			current
		DESCRIPTION
			"An mlt test pass/fail value."
		SYNTAX 			INTEGER  { 
                                        pass ( 1 ) , 
                                        fail ( 2 ), 
                                        notAvailable ( 3 ) } 
		
	MltTestRingerResult ::= TEXTUAL-CONVENTION 
		STATUS			current
		DESCRIPTION
			"An mlt ringer test result value."
		SYNTAX 			INTEGER  { 
                                        pass ( 1 ) , 
                                        fail ( 2 ), 
                                        notAvailable ( 3 ), 
                                        low ( 4 )  }

        MltTestYesNo ::= TEXTUAL-CONVENTION 
		STATUS			current
		DESCRIPTION
			"An mlt test pass/fail value."
		SYNTAX 			INTEGER  { 
                                        yes ( 1 ) , 
                                        no ( 2 ), 
                                        notAvailable ( 3 ) } 

-- The Metallic Loop Test Configuration group

	mltTestConfig	OBJECT IDENTIFIER
		::=  {  occamMltMib  1  }


-- The Metallic Loop Test Status group

	mltTestStatus	OBJECT IDENTIFIER
		::=  {  occamMltMib  2  }


-- The Metallic Loop Test Results group

	mltTestResults	OBJECT IDENTIFIER
		::=  {  occamMltMib  3  }
		
-- The Metallic Loop Test Notifications group
		
	mltTestNotifications	OBJECT IDENTIFIER
		::=  {  occamMltMib  4  }


-- Objects of the MLT Configuration group

	mltTestIdentifier	OBJECT-TYPE	
		SYNTAX			MltTestIdentifier
		MAX-ACCESS		read-write
		STATUS			current
		DESCRIPTION
			"Selects the mlt test to be run.
			Setting this value starts a test.
			 
			This is a required parameter.
			 
                        Approximate expected test durations are as 
                        follows:
			 
			 statusSuite 			1 second
			 mltSuite 			1 minute
			 activeModeVoltages		3 seconds
			 highImpedanceModeVoltages	9 seconds
			 dcResistance			18 seconds
			 capacitance			18 seconds
			 loopDetect			9 seconds
			 loopLength			9 seconds."
		::=  {  mltTestConfig  1  }

	mltTestType	OBJECT-TYPE	
		SYNTAX			MltTestType
		MAX-ACCESS		read-write
		STATUS			current
		DESCRIPTION
			"Selects if a test is requested (only run if port
                        is not in use) or forced.
			This is an optional parameter. If not specified, 
                        the request option is used."
		::=  {  mltTestConfig  2  }

	mltTestPort	OBJECT-TYPE	
		SYNTAX			Integer32  ( 1 .. 48  ) 
		MAX-ACCESS		read-write
		STATUS			current
		DESCRIPTION
			"Selects voice channel on which test will be run.
			 This is a required parameter."
		::=  {  mltTestConfig  3  }

	mltDcResistanceRange	OBJECT-TYPE	
		SYNTAX			Integer32  ( 0 .. 3  ) 
		MAX-ACCESS		read-write
		STATUS			current
		DESCRIPTION
			"Selects DC Resistance range value.
                        This is an optional paramater. Default is 0
                        (auto mode)."
		::=  {  mltTestConfig  4  }

	mltLoopLengthMultiplier	OBJECT-TYPE	
		SYNTAX			Integer32  ( 10 .. 200  ) 
		MAX-ACCESS		read-write
		STATUS			current
		DESCRIPTION
			"Selects loop length multiplier in nf. This is an
                        optional parameter. If not specified an internal
                        default value of 83nF/mile is used."
		::=  {  mltTestConfig  5  }

     mltLoopDetectThreshold	OBJECT-TYPE	
		SYNTAX			Integer32  ( 5 .. 200  ) 
		MAX-ACCESS		read-write
		STATUS			current
		DESCRIPTION
			"Selects the detection threshold in nF. 
			 This is an optional parameter. If not supplied,
                         a loop detection threshold of 10nF is used."
		::=  {  mltTestConfig  6  }


-- Objects of the MLT Test Status group

	mltLastTestStatus	OBJECT-TYPE	
		SYNTAX			MltTestStatus
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"Indicates the status of the last run mlt test.
                        Given that the various mlt tests take several
                        seconds to 1 1/2 minutes to run, it is suggested
                        that status polls be spaced 10-20 seconds apart. 
                        Additionally, a monitoring application could 
                        wait for the testComplete notification."
		::=  {  mltTestStatus  1  }
		
	mltErrorText		OBJECT-TYPE
		SYNTAX			OCTET STRING
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"Indicates the textual error in the case of an
                        aborted test."
		::= { mltTestStatus 2 }


-- Objects of the MLT Test Results group

-- mlt status results table
	mltStatusResultsTable	OBJECT-TYPE
		SYNTAX		SEQUENCE  OF  MltStatusResultsEntry
		MAX-ACCESS	not-accessible
		STATUS		current
		DESCRIPTION
			"This table provides result of the status test
                        suite."
		::=  { mltTestResults  1 }

	mltStatusResultsEntry	OBJECT-TYPE
		SYNTAX		MltStatusResultsEntry
		MAX-ACCESS	not-accessible
		STATUS		current
		DESCRIPTION
			"Entry holding information about results
			of status suite tests.

                        Note that a numerical result value of -999 means 
                        that there was an error of some sort and the 
                        value could not be measured."
		INDEX		{  mltTestPort  }
		::=  { mltStatusResultsTable 1 }

	MltStatusResultsEntry  ::=  SEQUENCE {
		mltStatusAlarm  OCTET STRING,
		mltStatusHookState  MltTestHookState,
		mltStatusTransversalCurrent  Integer32,
		mltStatusLongitudinalCurrent  Integer32,
		mltStatusTipVoltage  Integer32,
		mltStatusRingVoltage  Integer32,
		mltStatusTipRingVoltage  Integer32,
		mltStatusVdd  Integer32
		}


	mltStatusAlarm	OBJECT-TYPE	
		SYNTAX			OCTET STRING
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"Indicates GNK and/or OTEMP alarms active when
                        status test was run."
		::=  {  mltStatusResultsEntry  1  }


	mltStatusHookState	OBJECT-TYPE	
		SYNTAX			MltTestHookState
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"Indicates line hook state when status test was 
                        run."
		::=  {  mltStatusResultsEntry  2  }


	mltStatusTransversalCurrent	OBJECT-TYPE	
		SYNTAX			Integer32
		UNITS			"0.1 mA"
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"Indicates transversal current when status test
                        was run."
		::=  {  mltStatusResultsEntry  3  }


	mltStatusLongitudinalCurrent	OBJECT-TYPE	
		SYNTAX			Integer32
		UNITS			"0.1 mA"
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"Indicates Longitudinal current when status test
                        was run."
		::=  {  mltStatusResultsEntry  4  }


	mltStatusTipVoltage	OBJECT-TYPE	
		SYNTAX			Integer32
		UNITS			"0.1 V"
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"Indicates tip voltage when status test was run."
		::=  {  mltStatusResultsEntry  5  }


	mltStatusRingVoltage	OBJECT-TYPE	
		SYNTAX			Integer32
		UNITS			"0.1 V"
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"Indicates ring voltage when status test was run."
		::=  {  mltStatusResultsEntry  6  }
		
	mltStatusTipRingVoltage	OBJECT-TYPE	
		SYNTAX			Integer32
		UNITS			"0.1 V"
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"Indicates tip-ring voltage when status test was
                        run."
		::=  {  mltStatusResultsEntry  7  }


	mltStatusVdd	OBJECT-TYPE	
		SYNTAX			Integer32
		UNITS			"0.1 V"
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"Indicates Vdd when status test was run."
		::=  {  mltStatusResultsEntry  8  }
	
-- mlt test results table	
	mltTestResultsTable	OBJECT-TYPE
		SYNTAX		SEQUENCE  OF  MltTestResultsEntry
		MAX-ACCESS	not-accessible
		STATUS		current
		DESCRIPTION
			"This table provides result of the mlt test suite.
			Note that a numerical result value of -999 means 
                        that there was an error of some sort and the 
                        value could not be measured.
			Also, a resistance value of 9999 means that the 
                        result was greater than 1000 kOhms, but the exact
                        value could not be measured."
		::=  { mltTestResults  2 }

	mltTestResultsEntry	OBJECT-TYPE
		SYNTAX		MltTestResultsEntry
		MAX-ACCESS	not-accessible
		STATUS		current
		DESCRIPTION
			"Entry holding information about results
			of mlt suite tests."
		INDEX		{  mltTestPort  }
		::=  { mltTestResultsTable 1 }

	MltTestResultsEntry  ::=  SEQUENCE {
		mltTestAlarm  OCTET STRING,
		mltTestHookState  MltTestHookState,
		mltTestVdd  Integer32,
		mltTestActiveModeVoltagesVdctr  Integer32,
		mltTestActiveModeVoltagesVdctg  Integer32,
		mltTestActiveModeVoltagesVdcrg  Integer32,
		mltTestActiveModeVoltagesVactr  Integer32,
		mltTestActiveModeVoltagesVactg  Integer32,
		mltTestActiveModeVoltagesVacrg  Integer32,
		mltTestHighImpedanceModeVoltagesVdctr  Integer32,
		mltTestHighImpedanceModeVoltagesVdctg  Integer32,
		mltTestHighImpedanceModeVoltagesVdcrg  Integer32,
		mltTestHighImpedanceModeVoltagesVactr  Integer32,
		mltTestHighImpedanceModeVoltagesVactg  Integer32,
		mltTestHighImpedanceModeVoltagesVacrg  Integer32,
		mltTestDcCurrentsItransversal  Integer32,
		mltTestDcCurrentsIlongitudinal  Integer32,
		mltTestDcCurrentsItip  Integer32,
		mltTestDcCurrentsIring  Integer32,
		mltTestCapacitanceCeqtr  Integer32,
		mltTestCapacitanceCeqtg  Integer32,
		mltTestCapacitanceCeqrg  Integer32,
		mltTestResistanceRtr  Integer32,
		mltTestResistanceRtg  Integer32,
		mltTestResistanceRrg  Integer32,
		mltTestGr909HazardousPotentialTestResult MltTestPassFail,
		mltTestGr909ForeignEmfTestResult  MltTestPassFail,
		mltTestGr909FuseTestTipFuse  MltTestPassFail,
		mltTestGr909FuseTestRingFuse  MltTestPassFail,
		mltTestFuseTestTipFuse  MltTestPassFail,
		mltTestFuseTestRingFuse  MltTestPassFail,
		mltTestGr909ResistiveFaultTestResult  MltTestPassFail,
		mltTestGr909ReceiverOffhookTestResult  MltTestPassFail,
		mltTestGr909ReceiverOffhookTestResistance1  Integer32,
		mltTestGr909ReceiverOffhookTestResistance2  Integer32,
		mltTestGr909ReceiverOffhookTestDifference  Integer32,
		mltTestGr909RingerTestResult  MltTestRingerResult,
		mltTestGr909RingerTestRen  Integer32,
		mltTestErrors  OCTET STRING
		}


	mltTestAlarm	OBJECT-TYPE	
		SYNTAX			OCTET STRING
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"GNK and OTEMP bits set by the DuSLIC will be 
                        reported as alarms. GNK is typically cause by 
                        ground fault or foreign voltage condition.
                        OTEMP is set when the DuSLIC is experiencing
                        thermal overload. This parameter is 
                        non-intrusive."
		::=  {  mltTestResultsEntry  1  }
		
        mltTestHookState  OBJECT-TYPE
		SYNTAX			MltTestHookState
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"Hook state reflects the DuSLIC hook bit 
                        (offhook/onhook). This parameter is 
                        non-intrusive."
		::=  {  mltTestResultsEntry  2  }
		
	mltTestVdd  OBJECT-TYPE
		SYNTAX			Integer32
		UNITS			"0.1 V"
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"On HDPOTS, internal Voltage VDD will be 
                        reported and compared to statistically derived
                        thresholds. 
                        This parameter is intrusive during offhook but 
                        will be available during onhook."
		::=  {  mltTestResultsEntry  3  }
		
	mltTestActiveModeVoltagesVdctr  OBJECT-TYPE
		SYNTAX			Integer32
		UNITS			"0.1 Vdc"
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"Active Mode Tip/Ring AC Voltages:
                        In active mode, the DuSLIC drives the tip/ring 
                        in a normal no shutdown state. AC voltages for 
                        T-R, T-G and R-G will be reported. 
                        Active mode measurements will not be available
                        when alarm is detected. This parameter is 
                        intrusive and will be available in shutdown 
                        state only."
		::=  {  mltTestResultsEntry  4  }
		
	mltTestActiveModeVoltagesVdctg  OBJECT-TYPE
		SYNTAX			Integer32
		UNITS			"0.1 Vdc"
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"Active Mode Tip/Ring AC Voltages:
                        In active mode, the DuSLIC drives the tip/ring
                        in a normal no shutdown state. AC voltages for 
                        T-R, T-G and R-G will be reported. 
                        Active mode measurements will not be available 
                        when alarm is detected. This parameter is 
                        intrusive and will be available in shutdown 
                        state only."
		::=  {  mltTestResultsEntry  5  }
		
	mltTestActiveModeVoltagesVdcrg  OBJECT-TYPE
		SYNTAX			Integer32
		UNITS			"0.1 Vdc"
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"Active Mode Tip/Ring AC Voltages:
                        In active mode, the DuSLIC drives the tip/ring
                        in a normal no shutdown state. AC voltages for 
                        T-R, T-G and R-G will be reported. 
                        Active mode measurements will not be available
                        when alarm is detected. This parameter is 
                        intrusive and will be available in shutdown 
                        state only."
		::=  {  mltTestResultsEntry  6  }
		
	mltTestActiveModeVoltagesVactr  OBJECT-TYPE
		SYNTAX			Integer32
		UNITS			"0.1 Vrms"
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"Active Mode Tip/Ring AC Voltages:
                        In active mode, the DuSLIC drives the tip/ring
                        in a normal no shutdown state. Thus, VT and VR
                        measurements should be 0 volt. 
                        AC voltages for T-R, T-G and R-G will be 
                        reported. Active mode measurements will not be
                        available when alarm is detected. This parameter
                        is intrusive and will be available in shutdown 
                        state only."
		::=  {  mltTestResultsEntry  7  }
		
	mltTestActiveModeVoltagesVactg  OBJECT-TYPE
		SYNTAX		Integer32
		UNITS			"0.1 Vrms"
		MAX-ACCESS		read-only
		STATUS		current
		DESCRIPTION
                        "Active Mode Tip/Ring AC Voltages:
                        In active mode, the DuSLIC drives the tip/ring
                        in a normal no shutdown state. Thus, VT and VR		
			measurements should be 0 volt. AC voltages for T-R, T-G	
			and R-G will be reported. Active mode measurements will	
			not be available when alarm is detected. This parameter	
			is intrusive and will be available in shutdown state	
			only."
		::=  {  mltTestResultsEntry  8  }
		
	mltTestActiveModeVoltagesVacrg  OBJECT-TYPE
		SYNTAX			Integer32
		UNITS			"0.1 Vrms"
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"Active Mode Tip/Ring AC Voltages:
			In active mode, the DuSLIC drives the tip/ring in a	
			normal no shutdown state. Thus, VT and VR measurements	
			should be 0 volt. AC voltages for T-R, T-G and R-G will	
			be reported.  Active mode measurements will not be	
			available when alarm is detected. This parameter is	
			intrusive and will be available in shutdown state only."

		::=  {  mltTestResultsEntry  9  }
		
	mltTestHighImpedanceModeVoltagesVdctr  OBJECT-TYPE
		SYNTAX			Integer32
		UNITS			"0.1 Vdc"
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"High Impedance Mode Tip/Ring DC Voltages (Foreign	
			Voltages):
			In this mode, the DuSLIC tip and ring are in high	
			impedance. The measured voltages represent foreign	
			voltages. DC voltages for T-R, T-G and R-G will be	
			reported. This parameter is intrusive and will be	
			available in shutdown state only."
		::=  {  mltTestResultsEntry  10  }
		
	mltTestHighImpedanceModeVoltagesVdctg  OBJECT-TYPE
		SYNTAX			Integer32
		UNITS			"0.1 Vdc"
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"High Impedance Mode Tip/Ring DC Voltages (Foreign	
			Voltages):
			In this mode, the DuSLIC tip and ring are in high	
			impedance. The measured voltages represent foreign	
			voltages. DC voltages for T-R, T-G and R-G will be	
			reported. This parameter is intrusive and will be	
			available in shutdown state only."
		::=  {  mltTestResultsEntry  11  }
		
	mltTestHighImpedanceModeVoltagesVdcrg  OBJECT-TYPE
		SYNTAX			Integer32
		UNITS			"0.1 Vdc"
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"High Impedance Mode Tip/Ring DC Voltages (Foreign	
			Voltages):
			In this mode, the DuSLIC tip and ring are in high	
			impedance. The measured voltages represent foreign	
			voltages. DC voltages for T-R, T-G and R-G will be	
			reported. This parameter is intrusive and will be	
			available in shutdown state only."
		::=  {  mltTestResultsEntry  12  }
		
	mltTestHighImpedanceModeVoltagesVactr  OBJECT-TYPE
		SYNTAX			Integer32
		UNITS			"0.1 Vrms"
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"High Impedance Mode Tip/Ring AC Voltages (Foreign	
			Voltages): In this mode, the DuSLIC tip and ring are in	
			high impedance. The measured voltages represent foreign	
			voltages. AC voltages for T-R, T-G and R-G will be	
			reported. This parameter is intrusive and will be	
			available in shutdown state only."
		::=  {  mltTestResultsEntry  13  }
		
	mltTestHighImpedanceModeVoltagesVactg  OBJECT-TYPE
		SYNTAX			Integer32
		UNITS			"0.1 Vrms"
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"High Impedance Mode Tip/Ring AC Voltages (Foreign	
			Voltages):
			In this mode, the DuSLIC tip and ring are in high	
			impedance. The measured voltages represent foreign	
			voltages. AC voltages for T-R, T-G and R-G will be	
			reported. This parameter is intrusive and will be	
			available in shutdown state only."
		::=  {  mltTestResultsEntry  14  }
		
	mltTestHighImpedanceModeVoltagesVacrg  OBJECT-TYPE
		SYNTAX			Integer32
		UNITS			"0.1 Vrms"
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"High Impedance Mode Tip/Ring AC Voltages (Foreign	
			Voltages):
			In this mode, the DuSLIC tip and ring are in high	
			impedance. The measured voltages represent foreign	
			voltages. AC voltages for T-R, T-G and R-G will be	
			reported. This parameter is intrusive and will be	
			available in shutdown state only."
		::=  {  mltTestResultsEntry  15  }
		
	mltTestDcCurrentsItransversal  OBJECT-TYPE
		SYNTAX			Integer32
		UNITS			"0.1 mA"
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"Four DC currents will be reported: IT, IL, It and Ir. 
			In normal condition, currents will be measured in	
			active mode. These measurements will not be available if	
			alarm is present."
		::=  {  mltTestResultsEntry  16  }
		
	mltTestDcCurrentsIlongitudinal  OBJECT-TYPE
		SYNTAX			Integer32
		UNITS			"0.1 mA"
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"Four DC currents will be reported: IT, IL, It and Ir. 
			In normal condition, currents will be measured in active	
			mode. These measurements will not be available if alarm	
			is present."
		::=  {  mltTestResultsEntry  17  }
		
	mltTestDcCurrentsItip  OBJECT-TYPE
		SYNTAX			Integer32
		UNITS			"0.1 mA"
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"Four DC currents will be reported: IT, IL, It and Ir. 
			In normal condition, currents will be measured in active	
			mode. These measurements will not be available if alarm	
			is present."
		::=  {  mltTestResultsEntry  18  }
		
	mltTestDcCurrentsIring  OBJECT-TYPE
		SYNTAX			Integer32
		UNITS			"0.1 mA"
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"Four DC currents will be reported: IT, IL, It and Ir. 
			In normal condition, currents will be measured in active	
			mode. These measurements will not be available if alarm	
			is present."
		::=  {  mltTestResultsEntry  19  }
		
	mltTestCapacitanceCeqtr  OBJECT-TYPE
		SYNTAX			Integer32
		UNITS			"nF"
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"Capacitance measurements will support only single	
			element (2 terminal) circuit. In the presence of a	
			network of capacitance (figure 3), the individual	
			capacitance will not be resolved. The equivalent	
			capacitances CEQtr, CEQtg and CEQrg will be reported.	
			They represent the following:

	                       CEQtr = Ctr + Ctg/4 + Crg/4
	                       CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg)
	                       CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg)

			Capacitance measurements will not be available if fuse	
			test fails or alarm is present. This test is intrusive	
			and will be available in shutdown state only."
		::=  {  mltTestResultsEntry  20  }
		
	mltTestCapacitanceCeqtg  OBJECT-TYPE
		SYNTAX			Integer32
		UNITS			"nF"
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"Capacitance measurements will support only single	
			element (2 terminal) 
			circuit. In the presence of a network of capacitance	
			(figure 3), the 
			individual capacitance will not be resolved. The	
			equivalent capacitances CEQtr, CEQtg and CEQrg will be	
			reported. They represent the following:

	                       CEQtr = Ctr + Ctg/4 + Crg/4
	                       CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg)
	                       CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg)

			Capacitance measurements will not be available if fuse	
			test fails or alarm is present. This test is intrusive	
			and will be available in shutdown state only."
		::=  {  mltTestResultsEntry  21  }
		
	mltTestCapacitanceCeqrg  OBJECT-TYPE
		SYNTAX			Integer32
		UNITS			"nF"
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"Capacitance measurements will support only single	
			element (2 terminal) circuit. In the presence of a	
			network of capacitance (figure 3), the individual	
			capacitance will not be resolved. The equivalent	
			capacitances CEQtr, CEQtg and CEQrg will be reported.	
			They represent the following:

	                       CEQtr = Ctr + Ctg/4 + Crg/4
	                       CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg)
	                       CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg)

			Capacitance measurements will not be available if fuse	
			test fails or alarm is present. This test is intrusive	
			and will be available in shutdown state only."
		::=  {  mltTestResultsEntry  22  }
		
	mltTestResistanceRtr  OBJECT-TYPE
		SYNTAX			Integer32
		UNITS			"Ohm"
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"DC resistance measurements will be based on a 3	
			terminal circuit model. Rtr, Rtg and Rrg will be	
			provided. User will have the option of specifying 3	
			resistance ranges: (1) low, (2) medium, (3) high. If not	
			specified, auto mode will be used. Resistance		
			measurements will not be available if fuse test fails or	
			alarm is present. This parameter is intrusive. This test	
			is intrusive and will be available in shutdown state `	
			only."
		::=  {  mltTestResultsEntry  23  }
		
	mltTestResistanceRtg  OBJECT-TYPE
		SYNTAX			Integer32
		UNITS			"Ohm"
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"DC resistance measurements will be based on a 3	
			terminal circuit model. Rtr, Rtg and Rrg will be	
			provided. User will have the option of specifying 
			3 resistance ranges: (1) low, (2) medium, (3) high. If	
			not specified, auto mode will be used. Resistance	
			measurements will not be available if fuse test fails or	
			alarm is present. This parameter is intrusive. This test	
			is intrusive and will be available in shutdown state	
			only."
		::=  {  mltTestResultsEntry  24  }
		
	mltTestResistanceRrg  OBJECT-TYPE
		SYNTAX			Integer32
		UNITS			"Ohm"
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"DC resistance measurements will be based on a 3	
			terminal circuit model. Rtr, Rtg and Rrg will be	
			provided. User will have the option of specifying 
			3 resistance ranges: (1) low, (2) medium, (3) high. If	
			not specified, auto mode will be used. Resistance	
			measurements will not be available if fuse test fails or	
			alarm is present. This parameter is intrusive. This test	
			is intrusive and will be available in shutdown state	
			only."
		::=  {  mltTestResultsEntry  25  }
		
	mltTestGr909HazardousPotentialTestResult  OBJECT-TYPE
		SYNTAX			MltTestPassFail
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"This test fails if the T-G or R-G ac voltage is greater	
			than 50 volts rms or the T-G or R-G dc voltage is	
			greater than 135 volts. This test will report pass/fail.	
			This test is intrusive and will be available in shutdown	
			state only."
		::=  {  mltTestResultsEntry  26  }
		
	mltTestGr909ForeignEmfTestResult  OBJECT-TYPE
		SYNTAX			MltTestPassFail
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"This test fails if the T-G or R-G ac voltage is greater	
			than 50 volts rms or the T-G or R-G dc voltage is	
			greater than 135 volts. This test will report pass/fail.	
			This test is intrusive and will be available in shutdown	
			state only."
		::=  {  mltTestResultsEntry  27  }
		
	mltTestGr909FuseTestTipFuse  OBJECT-TYPE
		SYNTAX			MltTestPassFail
		MAX-ACCESS		read-only
		STATUS			obsolete
		DESCRIPTION
			"This test determines if these fuses are blown. This	
			test will return pass/fail for tip and ring. This test	
			will not be performed if alarm is present. This		
			parameter is intrusive. This test is intrusive and will	
			be available in shutdown state only.

			This object is obsolete. Object name was changed."
		::=  {  mltTestResultsEntry  28  }
		
	mltTestGr909FuseTestRingFuse  OBJECT-TYPE
		SYNTAX			MltTestPassFail
		MAX-ACCESS		read-only
		STATUS			obsolete
		DESCRIPTION
			"This test determines if these fuses are blown. This	
			test will return pass/fail for tip and ring. This test	
			will not be performed if alarm is present. This		
			parameter is intrusive. This test is intrusive and will	
			be available in shutdown state only.

			This object is obsolete. Object name was changed."
		::=  {  mltTestResultsEntry  29  }
		
        mltTestFuseTestTipFuse  OBJECT-TYPE
		SYNTAX			MltTestPassFail
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"This test determines if these fuses are blown. This	
			test will return pass/fail for tip and ring. This test	
			will not be performed if alarm is present. This		
			parameter is intrusive. This test is intrusive and will	
			be available in shutdown state only."
		::=  {  mltTestResultsEntry  38  }
		
	mltTestFuseTestRingFuse  OBJECT-TYPE
		SYNTAX			MltTestPassFail
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"This test determines if these fuses are blown. This	
			test will return pass/fail for tip and ring. This test	
			will not be performed if alarm is present. This		
			parameter is intrusive. This test is intrusive and will	
			be available in shutdown state only."
		::=  {  mltTestResultsEntry  39  }
		
	mltTestGr909ResistiveFaultTestResult  OBJECT-TYPE
		SYNTAX			MltTestPassFail
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"This test fails if the T-R, T-G or R-G dc resistance is	
			less than 150k ohm. This test will not be performed if	
			fuse test fails or alarm is present. This test will	
			return pass/fail. This test is intrusive and will be	
			available in shutdown state only."
		::=  {  mltTestResultsEntry  30  }
		
	mltTestGr909ReceiverOffhookTestResult  OBJECT-TYPE
		SYNTAX			MltTestPassFail
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"This test fails if a non-linearity in the T-R dc	
			resistance of greater than 15% when measured at two	
			different voltage levels exists. This test will not be	
			performed if fuse test fails or alarm is present. This	
			test will return the DC resistances at two different	
			operating points and the percent difference between the	
			two DC resistances. This test is intrusive and will be	
			available in shutdown state only. "
		::=  {  mltTestResultsEntry  31  }
		
	mltTestGr909ReceiverOffhookTestResistance1  OBJECT-TYPE
		SYNTAX			Integer32
		UNITS			"Ohm"
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"This test fails if a non-linearity in the T-R dc	
			resistance of greater than 15% when measured at two	
			different voltage levels exists. This test will not be	
			performed if fuse test fails or alarm is present. This	
			test will return the DC resistances at two different	
			operating points and the percent difference between the	
			two DC resistances. This test is intrusive and will be	
			available in shutdown state only. "
		::=  {  mltTestResultsEntry  32  }
		
	mltTestGr909ReceiverOffhookTestResistance2  OBJECT-TYPE
		SYNTAX			Integer32
		UNITS			"Ohm"
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"This test fails if a non-linearity in the T-R dc	
			resistance of greater than 15% when measured at two	
			different voltage levels exists. This test will not be	
			performed if fuse test fails or alarm is present. This	
			test will return the DC resistances at two different	
			operating points and the percent difference between the	
			two DC resistances. This test is intrusive and will be	
			available in shutdown state only. "
		::=  {  mltTestResultsEntry  33  }
		
	mltTestGr909ReceiverOffhookTestDifference  OBJECT-TYPE
		SYNTAX			Integer32
		UNITS			"%"
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"This test fails if a non-linearity in the T-R dc	
			resistance of greater than 15% when measured at two	
			different voltage levels exists. This test will not be	
			performed if fuse test fails or alarm is present. This	
			test will return the DC resistances at two different	
			operating points and the percent difference between the	
			two DC resistances. This test is intrusive and will be	
			available in shutdown state only. "
		::=  {  mltTestResultsEntry  34  }
		
	mltTestGr909RingerTestResult  OBJECT-TYPE
		SYNTAX			MltTestRingerResult
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"This test fails when the equivalent ringer count across	
			tip and ring is less than 0.175 REN or greater than 5	
			REN. This test will not run if fuse test fails or alarm	
			is present. This test will report passed/fail and the	
			REN number. This parameter is intrusive and will be	
			available in shutdown state shutdown only."
		::=  {  mltTestResultsEntry  35  }
		
	mltTestGr909RingerTestRen  OBJECT-TYPE
		SYNTAX			Integer32
		UNITS			"0.1 REN"
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"This test fails when the equivalent ringer count across	
			tip and ring is less than 0.175 REN or greater than 5	
			REN. This test will not run if fuse test fails or alarm	
			is present. This test will report passed/fail and the	
			REN number. This parameter is intrusive and will be	
			available in shutdown state shutdown only."
		::=  {  mltTestResultsEntry  36  }
		
	mltTestErrors  OBJECT-TYPE
		SYNTAX			OCTET STRING
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"Indicates GNK and/or OTEMP alarms active when test was	
			run."
		::=  {  mltTestResultsEntry  37  }

-- mlt active mode voltages results table	
	mltActiveModeVoltagesResultsTable	OBJECT-TYPE
		SYNTAX		SEQUENCE  OF  MltActiveModeVoltagesResultsEntry
		MAX-ACCESS	not-accessible
		STATUS		current
		DESCRIPTION
			"This table provides results of the mlt active mode	
			voltages test.
			Note that a numerical result value of -999 means that	
			there was an error of some sort and the value could not	
			be measured."
		::=  { mltTestResults  3 }

	mltActiveModeVoltagesResultsEntry	OBJECT-TYPE
		SYNTAX		MltActiveModeVoltagesResultsEntry
		MAX-ACCESS	not-accessible
		STATUS		current
		DESCRIPTION
			"Entry holding information about results
			of mlt active mode voltages test."
		INDEX		{  mltTestPort  }
		::=  { mltActiveModeVoltagesResultsTable 1 }

	MltActiveModeVoltagesResultsEntry  ::=  SEQUENCE {
		mltActiveModeVoltagesVdctr  Integer32,
		mltActiveModeVoltagesVdctg  Integer32,
		mltActiveModeVoltagesVdcrg  Integer32,
		mltActiveModeVoltagesVactr  Integer32,
		mltActiveModeVoltagesVactg  Integer32,
		mltActiveModeVoltagesVacrg  Integer32,
		mltActiveModeVoltagesErrors  OCTET STRING
		}
		
	mltActiveModeVoltagesVdctr  OBJECT-TYPE
		SYNTAX			Integer32
		UNITS			"0.1 Vdc"
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"Active Mode Tip/Ring AC Voltages:
			In active mode, the DuSLIC drives the tip/ring in a	
			normal no shutdown state. AC voltages for T-R, T-G and	
			R-G will be reported. 
			Active mode measurements will not be available when	
			alarm is detected. This parameter is intrusive and will	
			be available in shutdown state only."
		::=  {  mltActiveModeVoltagesResultsEntry  1  }
		
	mltActiveModeVoltagesVdctg  OBJECT-TYPE
		SYNTAX			Integer32
		UNITS			"0.1 Vdc"
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"Active Mode Tip/Ring AC Voltages:
			In active mode, the DuSLIC drives the tip/ring in a	
			normal no shutdown state. AC voltages for T-R, T-G and	
			R-G will be reported.  Active mode measurements will not	
			be available when alarm is detected. This parameter is	
			intrusive and will be available in shutdown state only."
		::=  {  mltActiveModeVoltagesResultsEntry  2  }
		
	mltActiveModeVoltagesVdcrg  OBJECT-TYPE
		SYNTAX			Integer32
		UNITS			"0.1 Vdc"
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"Active Mode Tip/Ring AC Voltages:
			In active mode, the DuSLIC drives the tip/ring in a	
			normal no shutdown state. AC voltages for T-R, T-G and	
			R-G will be reported. Active mode measurements will not	
			be available when alarm is detected. This parameter is	
			intrusive and will be available in shutdown state only."
		::=  {  mltActiveModeVoltagesResultsEntry  3  }
		
	mltActiveModeVoltagesVactr  OBJECT-TYPE
		SYNTAX			Integer32
		UNITS			"0.1 Vrms"
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"Active Mode Tip/Ring AC Voltages:
			In active mode, the DuSLIC drives the tip/ring in a	
			normal no shutdown state. Thus, VT and VR measurements	
			should be 0 volt. AC voltages for T-R, T-G and R-G will	
			be reported. Active mode measurements will not be	
			available when alarm is detected. This parameter is	
			intrusive and will be available in shutdown state only."
		::=  {  mltActiveModeVoltagesResultsEntry  4  }
		
	mltActiveModeVoltagesVactg  OBJECT-TYPE
		SYNTAX			Integer32
		UNITS			"0.1 Vrms"
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"Active Mode Tip/Ring AC Voltages:
                         In active mode, the DuSLIC drives the tip/ring in a	
			normal no shutdown state. Thus, VT and VR measurements	
			should be 0 volt. AC voltages for T-R, T-G and R-G will	
			be reported. Active mode measurements will not be	
			available when alarm is detected. This parameter is	
			intrusive and will be available in shutdown state only."
		::=  {  mltActiveModeVoltagesResultsEntry  5  }
		
	mltActiveModeVoltagesVacrg  OBJECT-TYPE
		SYNTAX			Integer32
		UNITS			"0.1 Vrms"
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"Active Mode Tip/Ring AC Voltages:
			In active mode, the DuSLIC drives the tip/ring in a	
			normal no shutdown state. Thus, VT and VR measurements	
			should be 0 volt. AC voltages for T-R, T-G and R-G will	
			be reported. 
			Active mode measurements will not be available when	
			alarm is detected. This parameter is intrusive and will	
			be available in shutdown state only."

		::=  {  mltActiveModeVoltagesResultsEntry  6  }
		
	 mltActiveModeVoltagesErrors  OBJECT-TYPE
		SYNTAX			OCTET STRING
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"Indicates GNK and/or OTEMP alarms active when test was	
			run."
		::=  {  mltActiveModeVoltagesResultsEntry  7  }

-- mlt high impedance mode voltages results table	
	mltHighImpedanceModeVoltagesResultsTable	OBJECT-TYPE
		SYNTAX		SEQUENCE  OF  
MltHighImpedanceModeVoltagesResultsEntry
		MAX-ACCESS	not-accessible
		STATUS		current
		DESCRIPTION
			"This table provides result of the mlt test suite.
			Note that a numerical result value of -999 means that	
			there was an error of some sort and the value could not	
			be measured."
		::=  { mltTestResults  4 }

	mltHighImpedanceModeVoltagesResultsEntry	OBJECT-TYPE
		SYNTAX		MltHighImpedanceModeVoltagesResultsEntry
		MAX-ACCESS	not-accessible
		STATUS		current
		DESCRIPTION
			"Entry holding information about results
			of mlt high impedance mode voltages test."
		INDEX		{  mltTestPort  }
		::=  { mltHighImpedanceModeVoltagesResultsTable 1 }

	MltHighImpedanceModeVoltagesResultsEntry  ::=  SEQUENCE {
		mltHighImpedanceModeVoltagesVdctr  Integer32,
		mltHighImpedanceModeVoltagesVdctg  Integer32,
		mltHighImpedanceModeVoltagesVdcrg  Integer32,
		mltHighImpedanceModeVoltagesVactr  Integer32,
		mltHighImpedanceModeVoltagesVactg  Integer32,
		mltHighImpedanceModeVoltagesVacrg  Integer32,
		mltHighImpedanceModeVoltagesErrors  OCTET STRING
		}
		
	mltHighImpedanceModeVoltagesVdctr  OBJECT-TYPE
		SYNTAX			Integer32
		UNITS			"0.1 Vdc"
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"High Impedance Mode Tip/Ring DC Voltages (Foreign	
			Voltages):
			In this mode, the DuSLIC tip and ring are in high	
			impedance. The measured voltages represent foreign	
			voltages. DC voltages for T-R, T-G and R-G will be	
			reported. This parameter is intrusive and will be	
			available in shutdown state only."
		::=  {  mltHighImpedanceModeVoltagesResultsEntry  1  }
		
	mltHighImpedanceModeVoltagesVdctg  OBJECT-TYPE
		SYNTAX			Integer32
		UNITS			"0.1 Vdc"
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"High Impedance Mode Tip/Ring DC Voltages (Foreign	
			Voltages):
			In this mode, the DuSLIC tip and ring are in high	
			impedance. The measured voltages represent foreign	
			voltages. DC voltages for T-R, T-G and R-G will be	
			reported. This parameter is intrusive and will be	
			available in shutdown state only."
		::=  {  mltHighImpedanceModeVoltagesResultsEntry  2  }
		
	mltHighImpedanceModeVoltagesVdcrg  OBJECT-TYPE
		SYNTAX			Integer32
		UNITS			"0.1 Vdc"
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"High Impedance Mode Tip/Ring DC Voltages (Foreign	
			Voltages): 
			In this mode, the DuSLIC tip and ring are in high	
			impedance. The measured voltages represent foreign	
			voltages. DC voltages for T-R, T-G and R-G will be	
			reported. This parameter is intrusive and will be	
			available in shutdown state only."
		::=  {  mltHighImpedanceModeVoltagesResultsEntry  3  }
		
	mltHighImpedanceModeVoltagesVactr  OBJECT-TYPE
		SYNTAX			Integer32
		UNITS			"0.1 Vrms"
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"High Impedance Mode Tip/Ring AC Voltages (Foreign	
			Voltages):
			In this mode, the DuSLIC tip and ring are in high	
			impedance. The measured voltages represent foreign	
			voltages. AC voltages for T-R, T-G and R-G will be	
			reported. This parameter is intrusive and will be	
			available in shutdown state only."
		::=  {  mltHighImpedanceModeVoltagesResultsEntry  4  }
		
	mltHighImpedanceModeVoltagesVactg  OBJECT-TYPE
		SYNTAX			Integer32
		UNITS			"0.1 Vrms"
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"High Impedance Mode Tip/Ring AC Voltages (Foreign	
			Voltages):
			In this mode, the DuSLIC tip and ring are in high	
			impedance.  The measured voltages represent foreign	
			voltages. AC voltages for T-R, T-G and R-G will be	
			reported. This parameter is intrusive and will be	
			available in shutdown state only."
		::=  {  mltHighImpedanceModeVoltagesResultsEntry  5  }
		
	mltHighImpedanceModeVoltagesVacrg  OBJECT-TYPE
		SYNTAX			Integer32
		UNITS			"0.1 Vrms"
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"High Impedance Mode Tip/Ring AC Voltages (Foreign	
			Voltages):
			In this mode, the DuSLIC tip and ring are in high	
			impedance. The measured voltages represent foreign	
			voltages. AC voltages for T-R, T-G and R-G will be	
			reported. This parameter is intrusive and will be	
			available in shutdown state only."
		::=  {  mltHighImpedanceModeVoltagesResultsEntry  6  }
				
	mltHighImpedanceModeVoltagesErrors  OBJECT-TYPE
		SYNTAX			OCTET STRING
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"Indicates GNK and/or OTEMP alarms active when test was	
			run."
		::=  {  mltHighImpedanceModeVoltagesResultsEntry  7  }
		
-- mlt DC resistance results table	
	mltDcResistanceResultsTable	OBJECT-TYPE
		SYNTAX		SEQUENCE  OF  MltDcResistanceResultsEntry
		MAX-ACCESS	not-accessible
		STATUS		current
		DESCRIPTION
			"This table provides result of the DC resistance test.
			Note that a numerical result value of -999 means that	
			there was an error of some sort and the value could not	
			be measured.  Also, a resistance value of 9999 means	
			that the result was greater than 1000 kOhms, but the	
			exact value could not be measured."
		::=  { mltTestResults  5 }

	mltDcResistanceResultsEntry	OBJECT-TYPE
		SYNTAX		MltDcResistanceResultsEntry
		MAX-ACCESS	not-accessible
		STATUS		current
		DESCRIPTION
			"Entry holding information about results
			of mlt DC resistance test."
		INDEX		{  mltTestPort  }
		::=  { mltDcResistanceResultsTable 1 }

	MltDcResistanceResultsEntry  ::=  SEQUENCE {
		mltDcResistanceRtr  Integer32,
		mltDcResistanceRtg  Integer32,
		mltDcResistanceRrg  Integer32,
		mltDcResistanceErrors  OCTET STRING
		}

		
	mltDcResistanceRtr  OBJECT-TYPE
		SYNTAX			Integer32
		UNITS			"Ohm"
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"DC resistance measurements will be based on a 3	
			terminal circuit model.  Rtr, Rtg and Rrg will be	
			provided. User will have the option of specifying 
			3 resistance ranges: (1) low, (2) medium, (3) high. If	
			not specified, auto mode will be used. Resistance	
			measurements will not be available if fuse test fails or	
			alarm is present. This parameter is intrusive. This test	
			is intrusive and will be available in shutdown state	
			only."
		::=  {  mltDcResistanceResultsEntry  1  }
		
	mltDcResistanceRtg  OBJECT-TYPE
		SYNTAX			Integer32
		UNITS			"Ohm"
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"DC resistance measurements will be based on a 3	
			terminal circuit model. Rtr, Rtg and Rrg will be	
			provided. User will have the option of specifying 
			3 resistance ranges: (1) low, (2) medium, (3) high. If	
			not specified, auto mode will be used. Resistance	
			measurements will not be available if fuse test fails or	
			alarm is present. This parameter is intrusive. This test	
			is intrusive and will be available in shutdown state	
			only."
		::=  {  mltDcResistanceResultsEntry  2  }
		
	mltDcResistanceRrg  OBJECT-TYPE
		SYNTAX			Integer32
		UNITS			"Ohm"
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"DC resistance measurements will be based on a 3	
			terminal circuit model. Rtr, Rtg and Rrg will be	
			provided. User will have the option of specifying 
			3 resistance ranges: (1) low, (2) medium, (3) high. If	
			not specified, auto mode will be used. Resistance	
			measurements will not be available if fuse test fails or	
			alarm is present. This parameter is intrusive. This test	
			is intrusive and will be available in shutdown state	
			only."
		::=  {  mltDcResistanceResultsEntry  3  }
				
	mltDcResistanceErrors  OBJECT-TYPE
		SYNTAX			OCTET STRING
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"Indicates GNK and/or OTEMP alarms active when test was	
			run."
		::=  {  mltDcResistanceResultsEntry  4  }
		
-- mlt capacitance results table	
	mltCapacitanceResultsTable	OBJECT-TYPE
		SYNTAX		SEQUENCE  OF  MltCapacitanceResultsEntry
		MAX-ACCESS	not-accessible
		STATUS		current
		DESCRIPTION
			"This table provides result of the mlt test suite.
			Note that a numerical result value of -999 means that 
			there was an error of some sort and the value could not	
			be measured."
		::=  { mltTestResults  6 }

	mltCapacitanceResultsEntry	OBJECT-TYPE
		SYNTAX		MltCapacitanceResultsEntry
		MAX-ACCESS	not-accessible
		STATUS		current
		DESCRIPTION
			"Entry holding information about results
			of mlt capacitance test."
		INDEX		{  mltTestPort  }
		::=  { mltCapacitanceResultsTable 1 }

	MltCapacitanceResultsEntry  ::=  SEQUENCE {
		mltCapacitanceCeqtr  Integer32,
		mltCapacitanceCeqtg  Integer32,
		mltCapacitanceCeqrg  Integer32,
		mltCapacitanceErrors  OCTET STRING
		}
		
	mltCapacitanceCeqtr  OBJECT-TYPE
		SYNTAX			Integer32
		UNITS			"nF"
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"Capacitance measurements will support only single	
			element (2 terminal) circuit. In the presence of a	
			network of capacitance (figure 3), the individual	
			capacitance will not be resolved. The equivalent	
			capacitances CEQtr, CEQtg and CEQrg will be reported.	
			They represent the following:

	                       CEQtr = Ctr + Ctg/4 + Crg/4
	                       CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg)
	                       CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg)

                         Capacitance measurements will not be available if fuse	
			test fails or alarm is present. This test is intrusive	
			and will be available in shutdown state only."
		::=  {  mltCapacitanceResultsEntry  1  }
		
	mltCapacitanceCeqtg  OBJECT-TYPE
		SYNTAX			Integer32
		UNITS			"nF"
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"Capacitance measurements will support only single	
			element (2 terminal) circuit. In the presence of a	
			network of capacitance (figure 3), the individual	
			capacitance will not be resolved. The equivalent	
			capacitances CEQtr, CEQtg and CEQrg will be reported.	
			They represent the following:

	                       CEQtr = Ctr + Ctg/4 + Crg/4
	                       CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg)
	                       CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg)

			Capacitance measurements will not be available if fuse	
			test fails or alarm is present. This test is intrusive	
			and will be available in shutdown state only."
		::=  {  mltCapacitanceResultsEntry  2  }
		
	mltCapacitanceCeqrg  OBJECT-TYPE
		SYNTAX			Integer32
		UNITS			"nF"
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"Capacitance measurements will support only single	
			element (2 terminal) circuit. In the presence of a	
			network of capacitance (figure 3), the individual	
			capacitance will not be resolved. The equivalent	
			capacitances CEQtr, CEQtg and CEQrg will be reported.	
			They represent the following:

	                       CEQtr = Ctr + Ctg/4 + Crg/4
	                       CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg)
	                       CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg)

			Capacitance measurements will not be available if fuse	
			test fails or alarm is present. This test is intrusive	
			and will be available in shutdown state only."
		::=  {  mltCapacitanceResultsEntry  3  }
				
	mltCapacitanceErrors  OBJECT-TYPE
		SYNTAX			OCTET STRING
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"Indicates GNK and/or OTEMP alarms active when test was	
			run."
		::=  {  mltCapacitanceResultsEntry  4  }

-- mlt loop detect results table	
	mltLoopDetectResultsTable	OBJECT-TYPE
		SYNTAX		SEQUENCE  OF  MltLoopDetectResultsEntry
		MAX-ACCESS	not-accessible
		STATUS		current
		DESCRIPTION
			"This table provides result of the mlt loop detect test.
			Note that a numerical result value of -999 means that	
			there was an error of some sort and the value could not	
			be measured."
		::=  { mltTestResults  7 }

	mltLoopDetectResultsEntry	OBJECT-TYPE
		SYNTAX		MltLoopDetectResultsEntry
		MAX-ACCESS	not-accessible
		STATUS		current
		DESCRIPTION
			"Entry holding information about results
			of mlt loop detect test."
		INDEX		{  mltTestPort  }
		::=  { mltLoopDetectResultsTable 1 }

	MltLoopDetectResultsEntry  ::=  SEQUENCE {
		mltLoopDetectLoopCapacitance  Integer32,
		mltLoopDetectDetectionThreshold  Integer32,
		mltLoopDetectLoopDetected  MltTestYesNo,
		mltLoopDetectErrors  OCTET STRING
		}
		
	mltLoopDetectLoopCapacitance  OBJECT-TYPE
		SYNTAX			Integer32
		UNITS			"nF"
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
                        "Loop detection will be based on tip-ring capacitance
                        measurement. User will be able to specify the detection
                        threshold. If not supplied,loop detection threshold of
                        10 nF will be used. This test will not be available if
                        fuse test fails or alarm is present. This test is
                        intrusive and will be available in shutdown state only."
		::=  {  mltLoopDetectResultsEntry  1  }
		
	mltLoopDetectDetectionThreshold  OBJECT-TYPE
		SYNTAX			Integer32
		UNITS			"nF"
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"Loop detection will be based on tip-ring capacitance
                        measurement. User will be able to specify the detection
                        threshold. If not supplied, loop detection threshold of
                        10 nF will be used. This test will not be available if
                        fuse test fails or alarm is present. This test is
                        intrusive and will be available in shutdown state only."
		::=  {  mltLoopDetectResultsEntry  2  }
		
	mltLoopDetectLoopDetected  OBJECT-TYPE
		SYNTAX			MltTestYesNo
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"Loop detection will be based on tip-ring capacitance
                        measurement. User will be able to specify the detection
                        threshold. If not supplied, loop detection threshold
                        of 10 nF will be used. This test will not be available
                        if fuse test fails or alarm is present. This test is
                        intrusive and will be available in shutdown state only."
		::=  {  mltLoopDetectResultsEntry  3  }
				
	mltLoopDetectErrors  OBJECT-TYPE
		SYNTAX			OCTET STRING
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"Indicates GNK and/or OTEMP alarms active when test
                        was run."
		::=  {  mltLoopDetectResultsEntry  4  }

-- mlt loop length results table	
	mltLoopLengthResultsTable	OBJECT-TYPE
		SYNTAX		SEQUENCE  OF  MltLoopLengthResultsEntry
		MAX-ACCESS	not-accessible
		STATUS		current
		DESCRIPTION
			"This table provides result of the mlt loop length test.
			Note that a numerical result value of -999 means that 
                        there was an error of some sort and the value could
                        not be measured."
		::=  { mltTestResults  8 }

	mltLoopLengthResultsEntry	OBJECT-TYPE
		SYNTAX		MltLoopLengthResultsEntry
		MAX-ACCESS	not-accessible
		STATUS		current
		DESCRIPTION
			"Entry holding information about results
			of mlt loop length test."
		INDEX		{  mltTestPort  }
		::=  { mltLoopLengthResultsTable 1 }

	MltLoopLengthResultsEntry  ::=  SEQUENCE {
		mltLoopLengthCapacitanceFactor  Integer32,
		mltLoopLengthLoopCapacitance  Integer32,
		mltLoopLengthLoopLength  Integer32,
		mltLoopLengthUncompensatedLoopCapacitance Integer32,
		mltLoopLengthUncompensatedLoopLength Integer32,
		mltLoopLengthErrors  OCTET STRING
		}
		
	mltLoopLengthCapacitanceFactor  OBJECT-TYPE
		SYNTAX			Integer32
		UNITS			"nF/mile"
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"Loop length estimate will be based on tip-ring
                        capacitance measurement. User will be able to 
                        specify the loop length multiplier. If not supplied, 
                        loop length multiplier of 83 nF/ mile will be used.
                        This test will not be available if fuse test fails
                        or alarm is present. This test is intrusive and will
                        be available in shutdown state only."
		::=  {  mltLoopLengthResultsEntry  1  }
		
	mltLoopLengthLoopCapacitance  OBJECT-TYPE
		SYNTAX			Integer32
		UNITS			"nF"
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"Loop length estimate will be based on tip-ring		
			capacitance measurement. User will be able to specify	
			the loop length multiplier. If not supplied, loop length	
			multiplier of 83 nF/ mile will be used. This test will	
			not be available if fuse test fails or alarm is present.	
			This test is intrusive and will be available in shutdown	
			state only. "
		::=  {  mltLoopLengthResultsEntry  2  }
		
	mltLoopLengthLoopLength  OBJECT-TYPE
		SYNTAX			Integer32
		UNITS			"ft"
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"Loop length estimate will be based on tip-ring		
			capacitance measurement. User will be able to specify	
			the loop length multiplier. If not supplied, loop length	
			multiplier of 83 nF/ mile will be used. This test will	
			not be available if fuse test fails or alarm is present.	
			This test is intrusive and will be available in shutdown 
			state only. "
		::=  {  mltLoopLengthResultsEntry  3  }
		
	mltLoopLengthUncompensatedLoopCapacitance  OBJECT-TYPE
		SYNTAX			Integer32
		UNITS			"nF"
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"Loop length estimate will be based on tip-ring		
			capacitance measurement. User will be able to specify	
			the loop length multiplier. If not supplied, loop length	
			multiplier of 83 nF/ mile will be used. This test will	
			not be available if fuse test fails or alarm is present.	
			This test is intrusive and will be available in shutdown	
			state only. This value has no DSL correction."
		::=  {  mltLoopLengthResultsEntry  4  }
		
	mltLoopLengthUncompensatedLoopLength  OBJECT-TYPE
		SYNTAX			Integer32
		UNITS			"ft"
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"Loop length estimate will be based on tip-ring		
			capacitance measurement. User will be able to specify	
			the loop length multiplier. If not supplied, loop length	
			multiplier of 83 nF/ mile will be used. This test will	
			not be available if fuse test fails or alarm is present.	
			This test is intrusive and will be available in shutdown	
			state only. This value has no DSL correction."
		::=  {  mltLoopLengthResultsEntry  5  }

				
	mltLoopLengthErrors  OBJECT-TYPE
		SYNTAX			OCTET STRING
		MAX-ACCESS		read-only
		STATUS			current
		DESCRIPTION
			"Indicates GNK and/or OTEMP alarms active when test was	
			run."
		::=  {  mltLoopLengthResultsEntry  6  }
		
-- notifications

	mltTestCompletedNotification	NOTIFICATION-TYPE
		OBJECTS			{ mltTestIdentifier, mltTestPort, 
					mltLastTestStatus, mltErrorText }
		STATUS			current
		DESCRIPTION		
			"This notification is sent to the 
			requesting host when the requested mlt 
			test has completed."
		::=  {  mltTestNotifications  1  }



END