summaryrefslogtreecommitdiff
path: root/MIBS/avtech/ROOMALERT7E-MIB
blob: bdb6a3e04ebf537610f85b30693bd9fc5e7f4c41 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
--
--defines ROOMALERT7E-MIB for SNMP agent extension of Room Alert 7E
--Contents:	Global Registration Module
--		Room Alert OIDs - Enterprise 20916
--Version:	2.0.3 
--Date:		11 September 2007
--Developed By: AVTECH Software, Inc.

--
--Copyright (c) 2007 AVTECH Software, Inc.
--

ROOMALERT7E-MIB DEFINITIONS ::= BEGIN


IMPORTS
	enterprises, IpAddress, Counter, TimeTicks
		FROM RFC1155-SMI
	OBJECT-TYPE
		FROM RFC-1212
	TRAP-TYPE
		FROM RFC-1215;


avtech      OBJECT IDENTIFIER ::= { enterprises 20916 }
products      OBJECT IDENTIFIER ::= { avtech 1 }
roomalert7e      OBJECT IDENTIFIER ::= { products 2 }
sensors       OBJECT IDENTIFIER ::= { roomalert7e 1 }
traps	      OBJECT IDENTIFIER ::= { roomalert7e 2 }
thresholds    OBJECT IDENTIFIER ::= { roomalert7e 3 }
temperature   OBJECT IDENTIFIER ::= { sensors 1 }
switch	      OBJECT IDENTIFIER ::= { sensors 2 }
 
-- Room Alert 7E MIB
-- Parameters 

tempreading1c OBJECT-TYPE
	SYNTAX  	INTEGER(0..65535)
	ACCESS		read-only
	STATUS		mandatory
	DESCRIPTION	"Temperature Sensor 1 (Celsius)"
::= { temperature 1 }

tempreading2c OBJECT-TYPE
	SYNTAX  	INTEGER(0..65535)
	ACCESS		read-only
	STATUS		mandatory
	DESCRIPTION	"Temperature Sensor 2 (Celsius)"
::= { temperature 2 }

tempreading3c OBJECT-TYPE
	SYNTAX  	INTEGER(0..65535)
	ACCESS		read-only
	STATUS		mandatory
	DESCRIPTION	"Temperature Sensor 3 (Celsius)"
::= { temperature 3 }


tempreading4c OBJECT-TYPE
	SYNTAX  	INTEGER(0..65535)
	ACCESS		read-only
	STATUS		mandatory
	DESCRIPTION	"Temperature Sensor 4 (Celsius)"
::= { temperature 4 }

tempreading1f OBJECT-TYPE
	SYNTAX  	INTEGER(0..65535)
	ACCESS		read-only
	STATUS		mandatory
	DESCRIPTION	"Temperature Sensor 1 (Fahrenheit)"
::= { temperature 5 }

tempreading2f OBJECT-TYPE
	SYNTAX  	INTEGER(0..65535)
	ACCESS		read-only
	STATUS		mandatory
	DESCRIPTION	"Temperature Sensor 2 (Fahrenheit)"
::= { temperature 6 }

tempreading3f OBJECT-TYPE
	SYNTAX  	INTEGER(0..65535)
	ACCESS		read-only
	STATUS		mandatory
	DESCRIPTION	"Temperature Sensor 3 (Fahrenheit)"
::= { temperature 7 }


tempreading4f OBJECT-TYPE
	SYNTAX  	INTEGER(0..65535)
	ACCESS		read-only
	STATUS		mandatory
	DESCRIPTION	"Temperature Sensor 4 (Fahrenheit)"
::= { temperature 8 }

switch1 OBJECT-TYPE
	SYNTAX  	INTEGER(0..65535)
	ACCESS		read-only
	STATUS		mandatory
	DESCRIPTION	"Switch Sensor 1 (0 = OFF, 1 = ON)"
::= { switch 1 }

switch2 OBJECT-TYPE
	SYNTAX  	INTEGER(0..65535)
	ACCESS		read-only
	STATUS		mandatory
	DESCRIPTION	"Switch Sensor 2 (0 = OFF, 1 = ON)"
::= { switch 2 }

switch3 OBJECT-TYPE
	SYNTAX  	INTEGER(0..65535)
	ACCESS		read-only
	STATUS		mandatory
	DESCRIPTION	"Switch Sensor 3 (0 = OFF, 1 = ON)"
::= { switch 3 }

alarmtemp1 OBJECT-TYPE
	SYNTAX  	INTEGER(0..2)
	ACCESS		read-only
	STATUS		mandatory
	DESCRIPTION	"Alarm for temperature 1
			0 = temperature OK
			1 = temperature too high
			2 = temperature too low"
::= { traps 1 }
	
alarmtemp2 OBJECT-TYPE
	SYNTAX  	INTEGER(0..2)
	ACCESS		read-only
	STATUS		mandatory
	DESCRIPTION	"Alarm for temperature 2
			0 = temperature OK
			1 = temperature too high
			2 = temperature too low"
::= { traps 2 }
	
alarmtemp3 OBJECT-TYPE
	SYNTAX  	INTEGER(0..2)
	ACCESS		read-only
	STATUS		mandatory
	DESCRIPTION	"Alarm for temperature 3
			0 = temperature OK
			1 = temperature too high
			2 = temperature too low"
::= { traps 3 }
	
alarmtemp4 OBJECT-TYPE
	SYNTAX  	INTEGER(0..2)
	ACCESS		read-only
	STATUS		mandatory
	DESCRIPTION	"Alarm for temperature 4
			0 = temperature OK
			1 = temperature too high
			2 = temperature too low"
::= { traps 4 }	
	
alarmswitch1 OBJECT-TYPE
	SYNTAX  	INTEGER(0..1)
	ACCESS		read-only
	STATUS		mandatory
	DESCRIPTION	"Alarm for switch sensor 1
			0 = Switch Open
			1 = Switch Closed"
::= { traps 5 }	
	
alarmswitch2 OBJECT-TYPE
	SYNTAX  	INTEGER(0..1)
	ACCESS		read-only
	STATUS		mandatory
	DESCRIPTION	"Alarm for switch sensor 2
			0 = Switch Open
			1 = Switch Closed"
::= { traps 6 }	
	
alarmswitch3 OBJECT-TYPE
	SYNTAX  	INTEGER(0..1)
	ACCESS		read-only
	STATUS		mandatory
	DESCRIPTION	"Alarm for switch sensor 3
			0 = Switch Open
			1 = Switch Closed"
::= { traps 7 }	
	
alarmmessage OBJECT-TYPE
	SYNTAX  	OCTET STRING
	ACCESS		read-write
	STATUS		mandatory
	DESCRIPTION	"Message string to send with trap messages"
::= { traps 8 }		
	
upperlimit1 OBJECT-TYPE
	SYNTAX  	INTEGER(0..15000)
	ACCESS		read-only
	STATUS		mandatory
	DESCRIPTION	"High temperature threshold for temperature sensor 1"
::= { thresholds 1 }		
	
lowerlimit1 OBJECT-TYPE
	SYNTAX  	INTEGER(0..15000)
	ACCESS		read-only
	STATUS		mandatory
	DESCRIPTION	"Low temperature threshold for temperature sensor 1"
::= { thresholds 2 }
	
upperlimit2 OBJECT-TYPE
	SYNTAX  	INTEGER(0..15000)
	ACCESS		read-only
	STATUS		mandatory
	DESCRIPTION	"High temperature threshold for temperature sensor 2"
::= { thresholds 3 }		
	
lowerlimit2 OBJECT-TYPE
	SYNTAX  	INTEGER(0..15000)
	ACCESS		read-only
	STATUS		mandatory
	DESCRIPTION	"Low temperature threshold for temperature sensor 2"
::= { thresholds 4 }
	
upperlimit3 OBJECT-TYPE
	SYNTAX  	INTEGER(0..15000)
	ACCESS		read-only
	STATUS		mandatory
	DESCRIPTION	"High temperature threshold for temperature sensor 3"
::= { thresholds 5 }		
	
lowerlimit3 OBJECT-TYPE
	SYNTAX  	INTEGER(0..15000)
	ACCESS		read-only
	STATUS		mandatory
	DESCRIPTION	"Low temperature threshold for temperature sensor 3"
::= { thresholds 6 }
	
upperlimit4 OBJECT-TYPE
	SYNTAX  	INTEGER(0..15000)
	ACCESS		read-only
	STATUS		mandatory
	DESCRIPTION	"High temperature threshold for temperature sensor 4"
::= { thresholds 7 }		
	
lowerlimit4 OBJECT-TYPE
	SYNTAX  	INTEGER(0..15000)
	ACCESS		read-only
	STATUS		mandatory
	DESCRIPTION	"Low temperature threshold for temperature sensor 4"
::= { thresholds 8 }	
	
-- ROOMALERT7E TRAPS

alarmstart1-7e TRAP-TYPE
	ENTERPRISE	roomalert7e
	VARIABLES	{ alarmmessage, tempreading1c, tempreading1f }
	DESCRIPTION	"A alarmstart1 trap signifies that the current
			temperature on sensor 1 is outside the 
			defined high or low threshold."
::= 1
	
room-alert-7e-snmp-trap TRAP-TYPE
	ENTERPRISE	roomalert7e
	VARIABLES	{ alarmmessage }
	DESCRIPTION	"A room-alert-7e-snmp-trap indicates that an alarm
			condition has occurred on the sensor inidcated
			by the alarmmessage variable."
::= 2
	
alarmstart2-7e TRAP-TYPE
	ENTERPRISE	roomalert7e
	VARIABLES	{ alarmmessage, tempreading2c, tempreading2f }
	DESCRIPTION	"A alarmstart2 trap signifies that the current
			temperature on sensor 2 is outside the 
			defined high or low threshold."
::= 3
	
alarmclear2-7e TRAP-TYPE
	ENTERPRISE	roomalert7e
	VARIABLES	{ alarmmessage, tempreading2c, tempreading2f }
	DESCRIPTION	"A alarmclear2 trap signifies that the current
			temperature on sensor 2 has returned to a 
			normal condition and is within the defined 
			high or low threshold."
::= 4
	
alarmstart3-7e TRAP-TYPE
	ENTERPRISE	roomalert7e
	VARIABLES	{ alarmmessage, tempreading3c, tempreading3f }
	DESCRIPTION	"A alarmstart3 trap signifies that the current
			temperature on sensor 3 is outside the 
			defined high or low threshold."
::= 5
	
alarmclear3-7e TRAP-TYPE
	ENTERPRISE	roomalert7e
	VARIABLES	{ alarmmessage, tempreading3c, tempreading3f }
	DESCRIPTION	"A alarmclear3 trap signifies that the current
			temperature on sensor 3 has returned to a 
			normal condition and is within the defined 
			high or low threshold."
::= 6
	
alarmstart4-7e TRAP-TYPE
	ENTERPRISE	roomalert7e
	VARIABLES	{ alarmmessage, tempreading4c, tempreading4f }
	DESCRIPTION	"A alarmstart4 trap signifies that the current
			temperature on sensor 4 is outside the 
			defined high or low threshold."
::= 7
	
alarmclear4-7e TRAP-TYPE
	ENTERPRISE	roomalert7e
	VARIABLES	{ alarmmessage, tempreading4c, tempreading4f }
	DESCRIPTION	"A alarmclear4 trap signifies that the current
			temperature on sensor 4 has returned to a 
			normal condition and is within the defined 
			high or low threshold."
::= 8
	
alarmstart5-7e TRAP-TYPE
	ENTERPRISE	roomalert7e
	VARIABLES	{ alarmmessage, switch1, switch1 }
	DESCRIPTION	"A alarmstart5 trap signifies that the current
			status of switch sensor 1 is outside the 
			defined threshold."
::= 9
	
alarmclear5-7e TRAP-TYPE
	ENTERPRISE	roomalert7e
	VARIABLES	{ alarmmessage, switch1, switch1 }
	DESCRIPTION	"A alarmclear5 trap signifies that the current
			status of switch sensor 1 is outside the 
			defined threshold."
::= 10
	
alarmstart6-7e TRAP-TYPE
	ENTERPRISE	roomalert7e
	VARIABLES	{ alarmmessage, switch2, switch2 }
	DESCRIPTION	"A alarmstart6 trap signifies that the current
			status of switch sensor 2 is outside the 
			defined threshold."
::= 11
	
alarmclear6-7e TRAP-TYPE
	ENTERPRISE	roomalert7e
	VARIABLES	{ alarmmessage, switch2, switch2 }
	DESCRIPTION	"A alarmclear6 trap signifies that the current
			status of switch sensor 2 is outside the 
			defined threshold."
::= 12
	
alarmstart7-7e TRAP-TYPE
	ENTERPRISE	roomalert7e
	VARIABLES	{ alarmmessage, switch3, switch3 }
	DESCRIPTION	"A alarmstart7 trap signifies that the current
			status of switch sensor 3 is outside the 
			defined threshold."
::= 13
	
alarmclear7-7e TRAP-TYPE
	ENTERPRISE	roomalert7e
	VARIABLES	{ alarmmessage, switch3, switch3 }
	DESCRIPTION	"A alarmclear7 trap signifies that the current
			status of switch sensor 3 is outside the 
			defined threshold."
::= 14
END