1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
1438
1439
1440
1441
1442
1443
1444
1445
1446
1447
1448
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490
1491
1492
1493
1494
1495
1496
1497
1498
1499
1500
1501
1502
1503
1504
1505
1506
1507
1508
1509
1510
1511
1512
1513
1514
1515
1516
1517
1518
1519
1520
1521
1522
1523
1524
1525
1526
1527
1528
1529
1530
1531
1532
1533
1534
1535
1536
1537
1538
1539
1540
1541
1542
1543
1544
1545
1546
1547
1548
1549
1550
1551
1552
1553
1554
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569
1570
1571
1572
1573
1574
1575
1576
1577
1578
1579
1580
1581
1582
1583
1584
1585
1586
1587
1588
1589
1590
1591
1592
1593
1594
1595
1596
1597
1598
1599
1600
1601
1602
1603
1604
1605
1606
1607
1608
1609
1610
1611
1612
1613
1614
1615
1616
1617
1618
1619
1620
1621
1622
1623
1624
1625
1626
1627
1628
1629
1630
1631
1632
1633
1634
1635
1636
1637
1638
1639
1640
1641
1642
1643
1644
1645
1646
1647
1648
1649
1650
1651
1652
1653
1654
1655
1656
1657
1658
1659
1660
1661
1662
1663
1664
1665
1666
1667
1668
1669
1670
1671
1672
1673
1674
1675
1676
1677
1678
1679
1680
1681
1682
1683
1684
1685
1686
1687
1688
1689
1690
1691
1692
1693
1694
1695
1696
1697
1698
1699
1700
1701
1702
1703
1704
1705
1706
1707
1708
1709
1710
1711
1712
1713
1714
1715
1716
1717
1718
1719
1720
1721
1722
1723
1724
1725
1726
1727
1728
1729
1730
1731
1732
1733
1734
1735
1736
1737
1738
1739
1740
1741
1742
1743
1744
1745
1746
1747
1748
1749
1750
1751
1752
1753
1754
1755
1756
1757
1758
1759
1760
1761
1762
1763
1764
1765
1766
1767
1768
1769
1770
1771
1772
1773
1774
1775
1776
1777
1778
1779
1780
1781
1782
1783
1784
1785
1786
1787
1788
1789
1790
1791
1792
1793
1794
1795
1796
1797
1798
1799
1800
1801
1802
1803
1804
1805
1806
1807
1808
1809
1810
1811
1812
1813
1814
1815
1816
1817
1818
1819
1820
1821
1822
1823
1824
1825
1826
1827
1828
1829
1830
1831
1832
1833
1834
1835
1836
1837
1838
1839
1840
1841
1842
1843
1844
1845
1846
1847
1848
1849
1850
1851
1852
1853
1854
1855
1856
1857
1858
1859
1860
1861
1862
1863
1864
1865
1866
1867
1868
1869
1870
1871
1872
1873
1874
1875
1876
1877
1878
1879
1880
1881
1882
1883
1884
1885
1886
1887
1888
1889
1890
1891
1892
1893
1894
1895
1896
1897
1898
1899
1900
1901
1902
1903
1904
1905
1906
1907
1908
1909
1910
1911
1912
1913
1914
1915
1916
1917
1918
1919
1920
1921
1922
1923
1924
1925
1926
1927
1928
1929
1930
1931
1932
1933
1934
1935
1936
1937
1938
1939
1940
1941
1942
1943
1944
1945
1946
1947
1948
1949
1950
1951
1952
1953
1954
1955
1956
1957
1958
1959
1960
1961
1962
1963
1964
1965
1966
1967
1968
1969
1970
1971
1972
1973
1974
1975
1976
1977
1978
1979
1980
1981
1982
1983
1984
1985
1986
1987
1988
1989
1990
1991
1992
1993
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
2025
2026
2027
2028
2029
2030
2031
2032
2033
2034
2035
2036
2037
2038
2039
2040
2041
2042
2043
2044
2045
2046
2047
2048
2049
2050
2051
2052
2053
2054
2055
2056
2057
2058
2059
2060
2061
2062
2063
2064
2065
2066
2067
2068
2069
2070
2071
2072
2073
2074
2075
2076
2077
2078
2079
2080
2081
2082
2083
2084
2085
2086
2087
2088
2089
2090
2091
2092
2093
2094
2095
2096
2097
2098
2099
2100
2101
2102
2103
2104
2105
2106
2107
2108
2109
2110
2111
2112
2113
2114
2115
2116
2117
2118
2119
2120
2121
2122
2123
2124
2125
2126
2127
2128
2129
2130
2131
2132
2133
2134
2135
2136
2137
2138
2139
2140
2141
2142
2143
2144
2145
2146
2147
2148
2149
2150
2151
2152
2153
2154
2155
2156
2157
2158
2159
2160
2161
2162
2163
2164
2165
2166
2167
2168
2169
2170
2171
2172
2173
2174
2175
2176
2177
2178
2179
2180
2181
2182
2183
2184
2185
2186
2187
2188
2189
2190
2191
2192
2193
2194
2195
2196
2197
2198
2199
2200
2201
2202
2203
2204
2205
2206
2207
2208
2209
2210
2211
2212
2213
2214
2215
2216
2217
2218
2219
2220
2221
2222
2223
2224
2225
2226
2227
2228
2229
2230
2231
2232
2233
2234
2235
2236
2237
2238
2239
2240
2241
2242
2243
2244
2245
2246
2247
2248
2249
2250
2251
2252
2253
2254
2255
2256
2257
2258
2259
2260
2261
2262
2263
2264
2265
2266
2267
2268
2269
2270
2271
2272
2273
2274
2275
2276
2277
2278
2279
2280
2281
2282
2283
2284
2285
2286
2287
2288
2289
2290
2291
2292
2293
2294
2295
2296
2297
2298
2299
2300
2301
2302
2303
2304
2305
2306
2307
2308
2309
2310
2311
2312
2313
2314
2315
2316
2317
2318
2319
2320
2321
2322
2323
2324
2325
2326
2327
2328
2329
2330
2331
2332
2333
2334
2335
2336
2337
2338
2339
2340
2341
2342
2343
2344
2345
2346
2347
2348
2349
2350
2351
2352
2353
2354
2355
2356
2357
2358
2359
2360
2361
2362
2363
2364
2365
2366
2367
2368
2369
2370
2371
2372
2373
2374
2375
2376
2377
2378
2379
2380
2381
2382
2383
2384
2385
2386
2387
2388
2389
2390
2391
2392
2393
2394
2395
2396
2397
2398
2399
2400
2401
2402
2403
2404
2405
2406
2407
2408
2409
2410
2411
2412
2413
2414
2415
2416
2417
2418
2419
2420
2421
2422
2423
2424
2425
2426
2427
2428
2429
2430
2431
2432
2433
2434
2435
2436
2437
2438
2439
2440
2441
2442
2443
2444
2445
2446
2447
2448
2449
2450
2451
2452
2453
2454
2455
2456
2457
2458
2459
2460
2461
2462
2463
2464
2465
2466
2467
2468
2469
2470
2471
2472
2473
2474
2475
2476
2477
2478
2479
2480
2481
2482
2483
2484
2485
2486
2487
2488
2489
2490
2491
2492
2493
2494
2495
2496
2497
2498
2499
2500
2501
2502
2503
2504
2505
2506
2507
2508
2509
2510
2511
2512
2513
2514
2515
2516
2517
2518
2519
2520
2521
2522
2523
2524
2525
2526
2527
2528
2529
2530
2531
2532
2533
2534
2535
2536
2537
2538
2539
2540
2541
2542
2543
2544
2545
2546
2547
2548
2549
2550
2551
2552
2553
2554
2555
2556
2557
2558
2559
2560
2561
2562
2563
2564
2565
2566
2567
2568
2569
2570
2571
2572
2573
2574
2575
2576
2577
2578
2579
2580
2581
2582
2583
2584
2585
2586
2587
2588
2589
2590
2591
2592
2593
2594
2595
2596
2597
2598
2599
2600
2601
2602
2603
2604
2605
2606
2607
2608
2609
2610
2611
2612
2613
2614
2615
2616
2617
2618
2619
2620
2621
2622
2623
2624
2625
2626
2627
2628
2629
2630
2631
2632
2633
2634
2635
2636
2637
2638
2639
2640
2641
2642
2643
2644
2645
2646
2647
2648
2649
2650
2651
2652
2653
2654
2655
2656
2657
2658
2659
2660
2661
2662
2663
2664
2665
2666
2667
2668
2669
2670
2671
2672
2673
2674
2675
2676
2677
2678
2679
2680
2681
2682
2683
2684
2685
2686
2687
2688
2689
2690
2691
2692
2693
2694
2695
2696
2697
2698
2699
2700
2701
2702
2703
2704
2705
2706
2707
2708
2709
2710
2711
2712
2713
2714
2715
2716
2717
2718
2719
2720
2721
2722
2723
2724
2725
2726
2727
2728
2729
2730
2731
2732
2733
2734
2735
2736
2737
2738
2739
2740
2741
2742
2743
2744
2745
2746
2747
2748
2749
2750
2751
2752
2753
2754
2755
2756
2757
2758
2759
2760
2761
2762
2763
2764
2765
2766
2767
2768
2769
2770
2771
2772
2773
2774
2775
2776
2777
2778
2779
2780
2781
2782
2783
2784
2785
2786
2787
2788
2789
2790
2791
2792
2793
2794
2795
2796
2797
2798
2799
2800
2801
2802
2803
2804
2805
2806
2807
2808
2809
2810
2811
2812
2813
2814
2815
2816
2817
2818
2819
2820
2821
2822
2823
2824
2825
2826
2827
2828
2829
2830
2831
2832
2833
2834
2835
2836
2837
2838
2839
2840
2841
2842
2843
2844
2845
2846
2847
2848
2849
2850
2851
2852
2853
2854
2855
2856
2857
2858
2859
2860
2861
2862
2863
2864
2865
2866
2867
2868
2869
2870
2871
2872
2873
2874
2875
2876
2877
2878
2879
2880
2881
2882
2883
2884
2885
2886
2887
2888
2889
2890
2891
2892
2893
2894
2895
2896
2897
2898
2899
2900
2901
2902
2903
2904
2905
2906
2907
2908
2909
2910
2911
2912
2913
2914
2915
2916
2917
2918
2919
2920
2921
2922
2923
2924
2925
2926
2927
2928
2929
2930
2931
2932
2933
2934
2935
2936
2937
2938
2939
2940
2941
2942
2943
2944
2945
2946
2947
2948
2949
2950
2951
2952
2953
2954
2955
2956
2957
2958
2959
2960
2961
2962
2963
2964
2965
2966
2967
2968
2969
2970
2971
2972
2973
2974
2975
2976
2977
2978
2979
2980
2981
2982
2983
2984
2985
2986
2987
2988
2989
2990
2991
2992
2993
2994
2995
2996
2997
2998
2999
3000
3001
3002
3003
3004
3005
3006
3007
3008
3009
3010
3011
3012
3013
3014
3015
3016
3017
3018
3019
3020
3021
3022
3023
3024
3025
3026
3027
3028
3029
3030
3031
3032
3033
3034
3035
3036
3037
3038
3039
3040
3041
3042
3043
3044
3045
3046
3047
3048
3049
3050
3051
3052
3053
3054
3055
3056
3057
3058
3059
3060
3061
3062
3063
3064
3065
3066
3067
3068
3069
3070
3071
3072
3073
3074
3075
3076
3077
3078
3079
3080
3081
3082
3083
3084
3085
3086
3087
3088
3089
3090
3091
3092
3093
3094
3095
3096
3097
3098
3099
3100
3101
3102
3103
3104
3105
3106
3107
3108
3109
3110
3111
3112
3113
3114
3115
3116
3117
3118
3119
3120
3121
3122
3123
3124
3125
3126
3127
3128
3129
3130
3131
3132
3133
3134
|
--------------------------------------------------------------------------------
-- Avocent PM MIB
-- Copyright 2010 Avocent Corporation
-- Revision: 2.0.1
-- Last Modified: Nov 24, 2010
--------------------------------------------------------------------------------
PM-MIB DEFINITIONS ::= BEGIN
IMPORTS
enterprises, OBJECT-TYPE, MODULE-IDENTITY, Integer32
FROM SNMPv2-SMI
DisplayString
FROM SNMPv2-TC
InterfaceIndex, InterfaceIndexOrZero
FROM IF-MIB;
--------------------------------------------------------------------------------
-- Object Groupings
--------------------------------------------------------------------------------
--@ Note: every product type should be uniquely identified underneath the
--@ Products object group. Each product should report its unique Products
--@ OBJECT IDENTIFIER in mib-2.system.sysObjectID. Please see the file
--@ "_Avocent Enterprise Object Identifier Assignment.txt" for a list of the
--@ IDs that have been assigned.
-- enterprises .1.3.6.1.4.1
-- avocent OBJECT IDENTIFIER ::= { enterprises 10418 }
pm MODULE-IDENTITY
LAST-UPDATED "201011240000Z"
ORGANIZATION "Avocent Corporation"
CONTACT-INFO "postal : Avocent Corporation
47281 Bayside Parkway
Fremont, CA 94538, USA
e-mail : Technical Support
techsupport@avocent.com"
DESCRIPTION
"This module defines the Avocent MIB extensions to
PM-PDU products."
REVISION "201011240000Z"
DESCRIPTION "Adding Power Management OIDs.
Fixed SYNTAX of some OIDs.
Updating OIDs DESCRIPTION to include not applicable values."
REVISION "201009240000Z"
DESCRIPTION "Syntax fixed to pass validation level 3."
REVISION "201004140000Z"
DESCRIPTION "Obsoleting fixed index OIDs from PDU table.
Added measurent type and alarm in PDU table.
Added missing power factor reset in outlet table.
Added sensor type and digital status in sensors table."
REVISION "200905210000Z"
DESCRIPTION "New tables for power measurements"
::= { enterprises 10418 17 }
pmProducts OBJECT IDENTIFIER ::= { pm 1 }
pmManagement OBJECT IDENTIFIER ::= { pm 2 }
--
pm1024 OBJECT IDENTIFIER ::= { pmProducts 1 } -- 10418.17.1.1
pm2003 OBJECT IDENTIFIER ::= { pmProducts 2 } -- 10418.17.1.2
pm2006 OBJECT IDENTIFIER ::= { pmProducts 3 } -- 10418.17.1.3
pm2024 OBJECT IDENTIFIER ::= { pmProducts 4 }
pm3003 OBJECT IDENTIFIER ::= { pmProducts 5 }
pm3006 OBJECT IDENTIFIER ::= { pmProducts 6 }
pm3024 OBJECT IDENTIFIER ::= { pmProducts 7 }
pm1010 OBJECT IDENTIFIER ::= { pmProducts 8 }
pm2010 OBJECT IDENTIFIER ::= { pmProducts 9 }
pm3010 OBJECT IDENTIFIER ::= { pmProducts 10 }
pm1020 OBJECT IDENTIFIER ::= { pmProducts 11 }
pm2020 OBJECT IDENTIFIER ::= { pmProducts 12 }
pm3020 OBJECT IDENTIFIER ::= { pmProducts 13 }
pmAppliance OBJECT IDENTIFIER ::= { pmManagement 1 } -- 10418.17.2.1
pmSessions OBJECT IDENTIFIER ::= { pmManagement 2 } -- 10418.17.2.2
pmPowerMgmt OBJECT IDENTIFIER ::= { pmManagement 5 } -- 10418.17.2.5
--
-- Note that traps are defined in a separate trap MIB
--
pmTrapObject OBJECT IDENTIFIER ::= { pmManagement 6 } -- 10418.17.2.6
--
-- pmAppliance
-- OBJECT IDENTIFIER ::= { pmManagement 1 } 10418.17.2.1
--
pmHostName OBJECT-TYPE
SYNTAX DisplayString ( SIZE (0..32) )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The appliance name"
::= { pmAppliance 1 }
pmProductModel OBJECT-TYPE
SYNTAX DisplayString ( SIZE (0..50) )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The appliance product model"
::= { pmAppliance 2 }
pmPartNumber OBJECT-TYPE
SYNTAX DisplayString ( SIZE (0..32) )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The part number of this appliance as shown on the label
attached or imprinted on the appliance."
::= { pmAppliance 3 }
pmSerialNumber OBJECT-TYPE
SYNTAX DisplayString ( SIZE (0..32) )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The serial number of this appliance as shown on the label
attached or imprinted on the appliance."
::= { pmAppliance 4 }
pmEIDNumber OBJECT-TYPE
SYNTAX DisplayString ( SIZE (0..32) )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The electronic ID number (EID) of this appliance as shown on the label
attached or imprinted on the appliance."
::= { pmAppliance 5 }
pmBootcodeVersion OBJECT-TYPE
SYNTAX DisplayString ( SIZE (0..32) )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The version of the bootcode of this appliance."
::= { pmAppliance 6 }
pmFirmwareVersion OBJECT-TYPE
SYNTAX DisplayString ( SIZE (0..32) )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The version of the firmware of this appliance."
::= { pmAppliance 7 }
pmReboot OBJECT-TYPE
SYNTAX INTEGER {
noAction(1),
reboot(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A set value of reboot(2) will reboot the appliance.
noAction(1) = always returned in a GET. Does nothing if SET.
reboot(2) = when SET the appliance immediately reboots."
::= { pmAppliance 9 }
--
-- pmSessions
-- OBJECT IDENTIFIER ::= { pmManagement 2 } 10418.17.2.2
--
pmActiveSessionsNumberOfSession OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of active sessions."
::= { pmSessions 1 }
pmActiveSessionsTable OBJECT-TYPE
SYNTAX SEQUENCE OF PmActiveSessionsTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the list of active sessions."
::= { pmSessions 2 }
pmActiveSessionsTableEntry OBJECT-TYPE
SYNTAX PmActiveSessionsTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"each entry has the information about the active session"
INDEX { pmActiveSessionsTableIndex }
::= { pmActiveSessionsTable 1 }
PmActiveSessionsTableEntry ::= SEQUENCE {
pmActiveSessionsTableIndex InterfaceIndexOrZero,
pmActiveSessionsTableUser DisplayString, -- user name
pmActiveSessionsTableGroup DisplayString, -- group name
pmActiveSessionsTableType DisplayString, -- RO/RW-ssh,telnet or web
pmActiveSessionsTableConnection DisplayString, -- type + target name
pmActiveSessionsTableSessionTime DisplayString, -- time of session
pmActiveSessionsTableFrom DisplayString, -- source of the session
pmActiveSessionsTableKill INTEGER
}
pmActiveSessionsTableIndex OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique index representing an entry in this table."
::= { pmActiveSessionsTableEntry 1 }
pmActiveSessionsTableUser OBJECT-TYPE
SYNTAX DisplayString ( SIZE (0..32) )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of the user that opens this session."
::= { pmActiveSessionsTableEntry 2 }
pmActiveSessionsTableGroup OBJECT-TYPE
SYNTAX DisplayString ( SIZE (0..32) )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of the group that the user belongs to."
::= { pmActiveSessionsTableEntry 3 }
pmActiveSessionsTableType OBJECT-TYPE
SYNTAX DisplayString ( SIZE (0..32) )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The session type."
::= { pmActiveSessionsTableEntry 4 }
pmActiveSessionsTableConnection OBJECT-TYPE
SYNTAX DisplayString ( SIZE (0..32) )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Connection type."
::= { pmActiveSessionsTableEntry 5 }
pmActiveSessionsTableSessionTime OBJECT-TYPE
SYNTAX DisplayString ( SIZE (0..32) )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Time of the session"
::= { pmActiveSessionsTableEntry 6 }
pmActiveSessionsTableFrom OBJECT-TYPE
SYNTAX DisplayString ( SIZE (0..32) )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The source IP address of the session."
::= { pmActiveSessionsTableEntry 7 }
pmActiveSessionsTableKill OBJECT-TYPE
SYNTAX INTEGER {
noAction(1),
killSession(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A set value of killSession(2) will kill the session.
noAction(1) = always returned in a GET. Does nothing if SET.
killSession(2)= when SET the appliance immediately kills the session."
::= { pmActiveSessionsTableEntry 8 }
--
-- pmPowerMgmt
-- OBJECT IDENTIFIER ::= { pmManagement 5 } 10418.17.2.5
--
pmPowerMgmtNumSerialPorts OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Serial Ports that has PDU connected on the appliance."
::= { pmPowerMgmt 1 }
pmPowerMgmtSerialTable OBJECT-TYPE
SYNTAX SEQUENCE OF PmPowerMgmtSerialTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about each serial port thas has PDU connect."
::= { pmPowerMgmt 2 }
pmPowerMgmtSerialTableEntry OBJECT-TYPE
SYNTAX PmPowerMgmtSerialTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about each serial port thas has PDU connect."
INDEX { pmPowerMgmtSerialTableIndex }
::= { pmPowerMgmtSerialTable 1 }
PmPowerMgmtSerialTableEntry ::= SEQUENCE {
pmPowerMgmtSerialTableIndex InterfaceIndex,
pmPowerMgmtSerialTablePortNumber Integer32,
pmPowerMgmtSerialTableDeviceName DisplayString,
pmPowerMgmtSerialTableNumberPDUs Integer32,
pmPowerMgmtSerialTableBuzzer Integer32,
pmPowerMgmtSerialTableSyslog Integer32,
pmPowerMgmtSerialTableOverCurrent Integer32,
pmPowerMgmtSerialTableCycleInterval Integer32,
pmPowerMgmtSerialTablePollRate Integer32,
pmPowerMgmtSerialTablePassWord DisplayString,
pmPowerMgmtSerialTableSave INTEGER,
pmPowerMgmtSerialTableRestore INTEGER
}
pmPowerMgmtSerialTableIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the register."
::= { pmPowerMgmtSerialTableEntry 1 }
pmPowerMgmtSerialTablePortNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of the serial port when the PDU is connected."
::= { pmPowerMgmtSerialTableEntry 2 }
pmPowerMgmtSerialTableDeviceName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The device name of this serial port."
::= { pmPowerMgmtSerialTableEntry 3 }
pmPowerMgmtSerialTableNumberPDUs OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of units connected in this serial port."
::= { pmPowerMgmtSerialTableEntry 4 }
pmPowerMgmtSerialTableBuzzer OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"set/get buzzer(s) on or off for the chain.
Returns 0 if not supported."
::= { pmPowerMgmtSerialTableEntry 10 }
pmPowerMgmtSerialTableSyslog OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"set/get syslog on or off for the chain.
Returns 0 if not supported."
::= { pmPowerMgmtSerialTableEntry 11 }
pmPowerMgmtSerialTableOverCurrent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"set/get over current proctection on or off for the chain.
Returns 0 if not supported."
::= { pmPowerMgmtSerialTableEntry 12 }
pmPowerMgmtSerialTableCycleInterval OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"set/get cycle interval for the chain in whole seconds.
Returns 0 if not supported."
::= { pmPowerMgmtSerialTableEntry 13 }
pmPowerMgmtSerialTablePollRate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"set/get the poll rate for the chain in whole seconds.
Returns 0 if not supported."
::= { pmPowerMgmtSerialTableEntry 14 }
pmPowerMgmtSerialTablePassWord OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"set the global password for admin user"
::= { pmPowerMgmtSerialTableEntry 15 }
pmPowerMgmtSerialTableSave OBJECT-TYPE
SYNTAX INTEGER {
noAction(1),
save(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"noAction(1) = always returned in a GET. Does nothing if SET.
save(2) = when SET the save command is sent to PDU."
::= { pmPowerMgmtSerialTableEntry 20 }
pmPowerMgmtSerialTableRestore OBJECT-TYPE
SYNTAX INTEGER {
noAction(1),
restore(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"noAction(1) = always returned in a GET. Does nothing if SET.
restore(2) = when SET the restore command is sent to PDU."
::= { pmPowerMgmtSerialTableEntry 21 }
pmPowerMgmtPDUTable OBJECT-TYPE
SYNTAX SEQUENCE OF PmPowerMgmtPDUTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the list of detected PDUs."
::= { pmPowerMgmt 3 }
pmPowerMgmtPDUTableEntry OBJECT-TYPE
SYNTAX PmPowerMgmtPDUTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"each entry has the information about the PDU."
INDEX { pmPowerMgmtPDUTablePortNumber, pmPowerMgmtPDUTablePduIndex }
::= { pmPowerMgmtPDUTable 1 }
PmPowerMgmtPDUTableEntry ::= SEQUENCE {
pmPowerMgmtPDUTablePortNumber InterfaceIndex, -- number of serial port
pmPowerMgmtPDUTablePduIndex InterfaceIndexOrZero,
pmPowerMgmtPDUTablePduId DisplayString, -- PDU identification
pmPowerMgmtPDUTablePortName DisplayString, -- Serial Port Name
pmPowerMgmtPDUTableModel DisplayString, -- PDU model
pmPowerMgmtPDUTableVendor DisplayString, -- Vendor
pmPowerMgmtPDUTableFirmwareVersion DisplayString, -- Firmware Version
pmPowerMgmtPDUTableNumberOfOutlets Integer32,
pmPowerMgmtPDUTableCurrentNOS Integer32, -- OBSOLETED number of current sensors
pmPowerMgmtPDUTableCurrent1Value Integer32, -- OBSOLETED actual value for current of the sensor 1
pmPowerMgmtPDUTableCurrent1Max Integer32, -- OBSOLETED max value for current of the sensor 1
pmPowerMgmtPDUTableCurrent2Value Integer32, -- OBSOLETED actual value for current of the sensor 2
pmPowerMgmtPDUTableCurrent2Max Integer32, -- OBSOLETED max value for current of the sensor 2
pmPowerMgmtPDUTableCurrent3Value Integer32, -- OBSOLETED actual value for current of the sensor 3
pmPowerMgmtPDUTableCurrent3Max Integer32, -- OBSOLETED max value for current of the sensor 3
pmPowerMgmtPDUTableTemperatureNOS Integer32, -- OBSOLETED number of temperature sensors
pmPowerMgmtPDUTableTemperature1Value Integer32, -- OBSOLETED actual value for Temperature 1
pmPowerMgmtPDUTableTemperature1Max Integer32, -- OBSOLETED max value for Temperature 1
pmPowerMgmtPDUTableTemperature2Value Integer32, -- OBSOLETED actual value for Temperaturet 2
pmPowerMgmtPDUTableTemperature2Max Integer32, -- OBSOLETED max value for Temperature 2
pmPowerMgmtPDUTableTemperature3Value Integer32, -- OBSOLETED actual value for Temperature 3
pmPowerMgmtPDUTableTemperature3Max Integer32, -- OBSOLETED max value for Temperature 3
pmPowerMgmtPDUTableHumidityNOS Integer32, -- OBSOLETED humidity number of humidity sensors
pmPowerMgmtPDUTableHumidity1Value Integer32, -- OBSOLETED actual value for Humidity of the sensor 1
pmPowerMgmtPDUTableHumidity1Max Integer32, -- OBSOLETED max value for Humidityof the sensor 1
pmPowerMgmtPDUTableHumidity2Value Integer32, -- OBSOLETED actual value for Humidity of the sensor 2
pmPowerMgmtPDUTableHumidity2Max Integer32, -- OBSOLETED max value for Humidity of the sensor 2
pmPowerMgmtPDUTableHumidity3Value Integer32, -- OBSOLETED actual value for Humidity of the sensor 3
pmPowerMgmtPDUTableHumidity3Max Integer32, -- OBSOLETED max value for Humidity of the sensor 3
pmPowerMgmtPDUTableVoltageNOS Integer32, -- OBSOLETED number of voltage sensor
pmPowerMgmtPDUTableVoltage1Value Integer32, -- OBSOLETED actual value for Voltage of the sensor 1
pmPowerMgmtPDUTableVoltage1Max Integer32, -- OBSOLETED max value for Voltage of the sensor 1
pmPowerMgmtPDUTableVoltage2Value Integer32, -- OBSOLETED actual value for Voltage of the sensor 2
pmPowerMgmtPDUTableVoltage2Max Integer32, -- OBSOLETED max value for Voltaget of the sensor 2
pmPowerMgmtPDUTableVoltage3Value Integer32, -- OBSOLETED actual value for Voltage of the sensor 3
pmPowerMgmtPDUTableVoltage3Max Integer32, -- OBSOLETED max value for Voltage of the sensor 3
pmPowerMgmtPDUTableNumberOfPhases Integer32, -- number of phases (0 if single phase)
pmPowerMgmtPDUTableNumberOfBanks Integer32, -- number of banks
pmPowerMgmtPDUTableNumberOfSensors Integer32, -- number of sensors
pmPowerMgmtPDUTableFactoryDefault INTEGER, -- set PDU to factory default settings
pmPowerMgmtPDUTableColdStartDelay Integer32, -- get/set PDUs cold start delay
pmPowerMgmtPDUTableReboot INTEGER, -- reboot the PDU
pmPowerMgmtPDUTableMaxCurrent Integer32, -- max value allowed for current
pmPowerMgmtPDUTableAlarm INTEGER, -- PDU alarm status
pmPowerMgmtPDUTableCurrentValue Integer32, -- actual value for current of the sensor
pmPowerMgmtPDUTableCurrentMax Integer32, -- max value for current
pmPowerMgmtPDUTableCurrentMin Integer32, -- min value for current
pmPowerMgmtPDUTableCurrentAvg Integer32, -- average value for current
pmPowerMgmtPDUTableCurrentReset INTEGER, -- reset the current stats
pmPowerMgmtPDUTablePowerValue Integer32, -- actual value for power
pmPowerMgmtPDUTablePowerMax Integer32, -- max value for power
pmPowerMgmtPDUTablePowerMin Integer32, -- min value for power
pmPowerMgmtPDUTablePowerAvg Integer32, -- average value for power
pmPowerMgmtPDUTablePowerReset INTEGER, -- reset the power stats
pmPowerMgmtPDUTablePowerType INTEGER, -- type of power measurement
pmPowerMgmtPDUTableVoltageValue Integer32, -- actual value for voltage
pmPowerMgmtPDUTableVoltageMax Integer32, -- max value for voltage
pmPowerMgmtPDUTableVoltageMin Integer32, -- min value for voltage
pmPowerMgmtPDUTableVoltageAvg Integer32, -- average value for voltage
pmPowerMgmtPDUTableVoltageReset INTEGER, -- reset the voltage stats
pmPowerMgmtPDUTableVoltageType INTEGER, -- type of voltage measurement
pmPowerMgmtPDUTablePowerFactorValue Integer32, -- actual value for powerfactor
pmPowerMgmtPDUTablePowerFactorMax Integer32, -- max value for powerfactor
pmPowerMgmtPDUTablePowerFactorMin Integer32, -- min value for powerfactor
pmPowerMgmtPDUTablePowerFactorAvg Integer32, -- average value for powerfactor
pmPowerMgmtPDUTablePowerFactorReset INTEGER, -- reset the powerfactor stats
pmPowerMgmtPDUTablePowerFactorType INTEGER, -- type of power factor measurement
pmPowerMgmtPDUTablePowerControl INTEGER, -- manage the outlets in this PDU
pmPowerMgmtPDUTableResetOCP INTEGER, -- reset the ocp (pdu wide)
pmPowerMgmtPDUTableCurrentHighCritical Integer32, -- get/set current high critical threshold
pmPowerMgmtPDUTableCurrentHighWarning Integer32, -- get/set current high warning threshold
pmPowerMgmtPDUTableCurrentLowWarning Integer32, -- get/set current low warning threshold
pmPowerMgmtPDUTableCurrentLowCritical Integer32, -- get/set current low critical threshold
pmPowerMgmtPDUTableEnergyValue Integer32, -- Energy value
pmPowerMgmtPDUTableEnergyStartTime DisplayString, -- time at which energy calculation commenced
pmPowerMgmtPDUTableEnergyReset INTEGER -- reset energy calculation and start time to now
}
pmPowerMgmtPDUTablePortNumber OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of serial port when the PDU is connected."
::= { pmPowerMgmtPDUTableEntry 1 }
pmPowerMgmtPDUTablePduIndex OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A PDU position in the chain."
::= { pmPowerMgmtPDUTableEntry 2 }
pmPowerMgmtPDUTablePduId OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"PDU identification."
::= { pmPowerMgmtPDUTableEntry 3 }
pmPowerMgmtPDUTablePortName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Name of serial port when the PDU is connected."
::= { pmPowerMgmtPDUTableEntry 4 }
pmPowerMgmtPDUTableModel OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Model of the PDU.
Returns N/A if not applicable."
::= { pmPowerMgmtPDUTableEntry 5 }
pmPowerMgmtPDUTableVendor OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Vendor of the PDU.
Returns N/A if not applicable."
::= { pmPowerMgmtPDUTableEntry 6 }
pmPowerMgmtPDUTableFirmwareVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Version of the PDU firmware.
Returns N/A if not applicable."
::= { pmPowerMgmtPDUTableEntry 7 }
pmPowerMgmtPDUTableNumberOfOutlets OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of outlets of the PDU."
::= { pmPowerMgmtPDUTableEntry 8 }
pmPowerMgmtPDUTableCurrentNOS OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Number of current sensors in the PDU."
::= { pmPowerMgmtPDUTableEntry 9 }
pmPowerMgmtPDUTableCurrent1Value OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Current of the sensor 1 in this PDU unit in AMP.
The value of this object is the actual current in
AMP * 10. You need to translate the readed value
(Ex. : value is 5, the current is 0.5 AMP.).
This OID is obsoleted. The value can be retrieved
from pmPowerMgmtPDUTableCurrentValue,
pmPowerMgmtPhasesTableCurrentValue, or
pmPowerMgmtOutletsTableCurrentValue"
::= { pmPowerMgmtPDUTableEntry 10 }
pmPowerMgmtPDUTableCurrent1Max OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"Maximum current of the sensor 1 in this PDU unit in AMP.
When the PDU does not have support for maximum value,
the value will be 0.
The value of this object is the actual current in
AMP * 10. You need to translate the readed value
(Ex. : value is 5, the current is 0.5 AMP.)
Clear this value, set it with Zero value.
This OID is obsoleted. The value can be retrieved
from pmPowerMgmtPDUTableCurrentMax,
pmPowerMgmtPhasesTableCurrentMax, or
pmPowerMgmtOutletsTableCurrentMax"
::= { pmPowerMgmtPDUTableEntry 11 }
pmPowerMgmtPDUTableCurrent2Value OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Current of the sensor 2 in this PDU unit in AMP.
The value of this object is the actual current in
AMP * 10. You need to translate the readed value
(Ex. : value is 5, the current is 0.5 AMP.).
This OID is obsoleted. The value can be retrieved
from pmPowerMgmtPDUTableCurrentValue,
pmPowerMgmtPhasesTableCurrentValue, or
pmPowerMgmtOutletsTableCurrentValue"
::= { pmPowerMgmtPDUTableEntry 12 }
pmPowerMgmtPDUTableCurrent2Max OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"Maximum current of the sensor 2 in this PDU unit in AMP.
When the PDU does not have support for maximum value,
the value will be 0.
The value of this object is the actual current in
AMP * 10. You need to translate the readed value
(Ex. : value is 5, the current is 0.5 AMP.)
Clear this value, set it with Zero value.
This OID is obsoleted. The value can be retrieved
from pmPowerMgmtPDUTableCurrentMax,
pmPowerMgmtPhasesTableCurrentMax, or
pmPowerMgmtOutletsTableCurrentMax"
::= { pmPowerMgmtPDUTableEntry 13}
pmPowerMgmtPDUTableCurrent3Value OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Current of the sensor 3 in this PDU unit in AMP.
The value of this object is the actual current in
AMP * 10. You need to translate the readed value
(Ex. : value is 5, the current is 0.5 AMP.)
This OID is obsoleted. The value can be retrieved
from pmPowerMgmtPDUTableCurrentValue,
pmPowerMgmtPhasesTableCurrentValue, or
pmPowerMgmtOutletsTableCurrentValue"
::= { pmPowerMgmtPDUTableEntry 14 }
pmPowerMgmtPDUTableCurrent3Max OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"Maximum current of the sensor 3 in this PDU unit in AMP.
When the PDU does not have support for maximum value,
the value will be 0.
The value of this object is the actual current in
AMP * 10. You need to translate the readed value
(Ex. : value is 5, the current is 0.5 AMP.)
Clear this value, set it with Zero value.
This OID is obsoleted. The value can be retrieved
from pmPowerMgmtPDUTableCurrentMax,
pmPowerMgmtPhasesTableCurrentMax, or
pmPowerMgmtOutletsTableCurrentMax"
::= { pmPowerMgmtPDUTableEntry 15 }
pmPowerMgmtPDUTableTemperatureNOS OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Number of temperature sensors in the PDU."
::= { pmPowerMgmtPDUTableEntry 16 }
pmPowerMgmtPDUTableTemperature1Value OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Temperature of this PM unit in Celsius degrees.
The value of this object is the actual temperature in
degrees C * 10. You need to translate the readed value
(Ex. : value is 240, the temperature is 24 Celsius.)
If the temperature measurement is not installed this
value will be 0.
Valid values are 5 to 999 ( 0.5 to 99.9 Celsius)."
::= { pmPowerMgmtPDUTableEntry 17 }
pmPowerMgmtPDUTableTemperature1Max OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"Maximum temperature detected in this PM unit in Celsius degrees.
The value will be Zero when the PDU does not have support for maximum value.
The value of this object is the actual temperature in
degrees C * 10. You need to translate the readed value
(Ex. : value is 240, the temperature is 24 Celsius.)
If the temperature measurement is not installed this
value will be 0.
Valid values are 5 to 999 ( 0.5 to 99.9 Celsius).
Set with Zero value to clear the max. temperature."
::= { pmPowerMgmtPDUTableEntry 18 }
pmPowerMgmtPDUTableTemperature2Value OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Temperature of this PM unit in Celsius degrees.
The value of this object is the actual temperature in
degrees C * 10. You need to translate the readed value
(Ex. : value is 240, the temperature is 24 Celsius.)
If the temperature measurement is not installed this
value will be 0.
Valid values are 5 to 999 ( 0.5 to 99.9 Celsius)."
::= { pmPowerMgmtPDUTableEntry 19 }
pmPowerMgmtPDUTableTemperature2Max OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"Maximum temperature detected in this PM unit in Celsius degrees.
The value will be Zero when the PDU does not have support for maximum value.
The value of this object is the actual temperature in
degrees C * 10. You need to translate the readed value
(Ex. : value is 240, the temperature is 24 Celsius.)
If the temperature measurement is not installed this
value will be 0.
Valid values are 5 to 999 ( 0.5 to 99.9 Celsius).
Set with Zero value to clear the max. temperature."
::= { pmPowerMgmtPDUTableEntry 20 }
pmPowerMgmtPDUTableTemperature3Value OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Temperature of this PM unit in Celsius degrees.
The value of this object is the actual temperature in
degrees C * 10. You need to translate the readed value
(Ex. : value is 240, the temperature is 24 Celsius.)
If the temperature measurement is not installed this
value will be 0.
Valid values are 5 to 999 ( 0.5 to 99.9 Celsius)."
::= { pmPowerMgmtPDUTableEntry 21 }
pmPowerMgmtPDUTableTemperature3Max OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"Maximum temperature detected in this PM unit in Celsius degrees.
The value will be Zero when the PDU does not have support for maximum value.
The value of this object is the actual temperature in
degrees C * 10. You need to translate the readed value
(Ex. : value is 240, the temperature is 24 Celsius.)
If the temperature measurement is not installed this
value will be 0.
Valid values are 5 to 999 ( 0.5 to 99.9 Celsius).
Set with Zero value to clear the max. temperature."
::= { pmPowerMgmtPDUTableEntry 22 }
pmPowerMgmtPDUTableHumidityNOS OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Number of humidity sensors in the PDU."
::= { pmPowerMgmtPDUTableEntry 23 }
pmPowerMgmtPDUTableHumidity1Value OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Humidity of this PM unit .
If the humidity measurement is not installed this
value will be 0."
::= { pmPowerMgmtPDUTableEntry 24 }
pmPowerMgmtPDUTableHumidity1Max OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"Maximum humidity detected in this PM unit.
If the humidity measurement is not installed or the PDU does not have support for maximum value this
value will be 0.
Set with Zero value to clear the max. temperature."
::= { pmPowerMgmtPDUTableEntry 25 }
pmPowerMgmtPDUTableHumidity2Value OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Humidity of this PM unit .
If the humidity measurement is not installed this
value will be 0."
::= { pmPowerMgmtPDUTableEntry 26 }
pmPowerMgmtPDUTableHumidity2Max OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"Maximum humidity detected in this PM unit.
If the humidity measurement is not installed or the PDU does not have support for maximum value this
value will be 0.
Set with Zero value to clear the max. temperature."
::= { pmPowerMgmtPDUTableEntry 27 }
pmPowerMgmtPDUTableHumidity3Value OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Humidity of this PM unit .
If the humidity measurement is not installed this
value will be 0."
::= { pmPowerMgmtPDUTableEntry 28 }
pmPowerMgmtPDUTableHumidity3Max OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"Maximum humidity detected in this PM unit.
If the humidity measurement is not installed or the PDU does not have support for maximum value this
value will be 0.
Set with Zero value to clear the max. temperature."
::= { pmPowerMgmtPDUTableEntry 29 }
pmPowerMgmtPDUTableVoltageNOS OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Number of voltage sensors in the PDU."
::= { pmPowerMgmtPDUTableEntry 30 }
pmPowerMgmtPDUTableVoltage1Value OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Voltage of this sensor in this PDU unit.
This OID is obsoleted. The value can be retrieved
from pmPowerMgmtPDUTableVoltageValue,
pmPowerMgmtPhasesTableVoltageValue, or
pmPowerMgmtOutletsTableVoltageValue"
::= { pmPowerMgmtPDUTableEntry 31 }
pmPowerMgmtPDUTableVoltage1Max OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"Maximum voltage of this sensor in this PDU unit.
Set with Zero value to clear the maximum voltage.
This OID is obsoleted. The value can be retrieved
from pmPowerMgmtPDUTableVoltageMax,
pmPowerMgmtPhasesTableVoltageMax, or
pmPowerMgmtOutletsTableVoltageMax"
::= { pmPowerMgmtPDUTableEntry 32 }
pmPowerMgmtPDUTableVoltage2Value OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Voltage of this sensor in this PDU unit.
This OID is obsoleted. The value can be retrieved
from pmPowerMgmtPDUTableVoltageValue,
pmPowerMgmtPhasesTableVoltageValue, or
pmPowerMgmtOutletsTableVoltageValue"
::= { pmPowerMgmtPDUTableEntry 33 }
pmPowerMgmtPDUTableVoltage2Max OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"Maximum voltage of this sensor in this PDU unit.
Set with Zero value to clear the maximum voltage.
This OID is obsoleted. The value can be retrieved
from pmPowerMgmtPDUTableVoltageMax,
pmPowerMgmtPhasesTableVoltageMax, or
pmPowerMgmtOutletsTableVoltageMax"
::= { pmPowerMgmtPDUTableEntry 34 }
pmPowerMgmtPDUTableVoltage3Value OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Voltage of this sensor in this PDU unit.
This OID is obsoleted. The value can be retrieved
from pmPowerMgmtPDUTableVoltageValue,
pmPowerMgmtPhasesTableVoltageValue, or
pmPowerMgmtOutletsTableVoltageValue"
::= { pmPowerMgmtPDUTableEntry 35 }
pmPowerMgmtPDUTableVoltage3Max OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"Maximum voltage of this sensor in this PDU unit.
Set with Zero value to clear the maximum voltage.
This OID is obsoleted. The value can be retrieved
from pmPowerMgmtPDUTableVoltageMax,
pmPowerMgmtPhasesTableVoltageMax, or
pmPowerMgmtOutletsTableVoltageMax"
::= { pmPowerMgmtPDUTableEntry 36 }
pmPowerMgmtPDUTableNumberOfPhases OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of phases of the PDU."
::= { pmPowerMgmtPDUTableEntry 37 }
pmPowerMgmtPDUTableNumberOfBanks OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of banks in the PDU."
::= { pmPowerMgmtPDUTableEntry 38 }
pmPowerMgmtPDUTableNumberOfSensors OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of sensors in the PDU."
::= { pmPowerMgmtPDUTableEntry 40 }
pmPowerMgmtPDUTableFactoryDefault OBJECT-TYPE
SYNTAX INTEGER {
noAction(1),
reset(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A set value of 2 will set the PDU to factory default settings.
noAction(1) = always returned in a GET. Does nothing if SET.
reset(2) = when SET the factory default command is sent to the PDU."
::= { pmPowerMgmtPDUTableEntry 41 }
pmPowerMgmtPDUTableColdStartDelay OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"PDUs cold start delay in whole seconds (0-60).
Returns 0 if not supported."
::= { pmPowerMgmtPDUTableEntry 42 }
pmPowerMgmtPDUTableReboot OBJECT-TYPE
SYNTAX INTEGER {
noAction(1),
reboot(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A set value of power*(2) will send command to PDU.
noAction(1) = always returned in a GET. Does nothing if SET.
reboot(2) = when SET the reboot command is sent to PDU."
::= { pmPowerMgmtPDUTableEntry 43 }
pmPowerMgmtPDUTableMaxCurrent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum value of current allowed in the PDU (A x 10)."
::= { pmPowerMgmtPDUTableEntry 44 }
pmPowerMgmtPDUTableAlarm OBJECT-TYPE
SYNTAX INTEGER {
normal (1),
blow-fuse (2),
hw-ocp (3),
high-critical (4),
high-warning (5),
low-warning (6),
low-critical (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Show the PDU alarm status.
Returns 0 if not supported."
::= { pmPowerMgmtPDUTableEntry 45 }
--@ Note: Intentionally left space for future expansion (thanks!)
pmPowerMgmtPDUTableCurrentValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Actual value of current in the PDU (A x 10).
Returns 0 if not supported."
::= { pmPowerMgmtPDUTableEntry 50 }
pmPowerMgmtPDUTableCurrentMax OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum value of current in the PDU (A x 10).
Returns 0 if not supported."
::= { pmPowerMgmtPDUTableEntry 51 }
pmPowerMgmtPDUTableCurrentMin OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Minimum value of current in the PDU (A x 10).
Returns 0 if not supported."
::= { pmPowerMgmtPDUTableEntry 52 }
pmPowerMgmtPDUTableCurrentAvg OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average value of current in the PDU (A x 10).
Returns 0 if not supported."
::= { pmPowerMgmtPDUTableEntry 53 }
pmPowerMgmtPDUTableCurrentReset OBJECT-TYPE
SYNTAX INTEGER {
noAction(1),
reset(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"noAction(1) = always returned in a GET. Does nothing if SET.
reset(2) = when SET the reset command is sent to PDU."
::= { pmPowerMgmtPDUTableEntry 54 }
pmPowerMgmtPDUTablePowerValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Actual value of power in the PDU (W x 10).
Returns 0 if not supported."
::= { pmPowerMgmtPDUTableEntry 60 }
pmPowerMgmtPDUTablePowerMax OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum value of power in the PDU (W x 10).
Returns 0 if not supported."
::= { pmPowerMgmtPDUTableEntry 61 }
pmPowerMgmtPDUTablePowerMin OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Minimum value of power in the PDU (W x 10).
Returns 0 if not supported."
::= { pmPowerMgmtPDUTableEntry 62 }
pmPowerMgmtPDUTablePowerAvg OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average value of power in the PDU (W x 10).
Returns 0 if not supported."
::= { pmPowerMgmtPDUTableEntry 63 }
pmPowerMgmtPDUTablePowerReset OBJECT-TYPE
SYNTAX INTEGER {
noAction(1),
reset(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"noAction(1) = always returned in a GET. Does nothing if SET.
reset(2) = when SET the reset command is sent to PDU."
::= { pmPowerMgmtPDUTableEntry 64 }
pmPowerMgmtPDUTablePowerType OBJECT-TYPE
SYNTAX INTEGER {
none-sensor (0),
estimated (1),
measured (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Type of power values.
Returns 0 if not supported."
::= { pmPowerMgmtPDUTableEntry 65 }
pmPowerMgmtPDUTableVoltageValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Actual value of voltage in the PDU (V).
Returns 0 if not supported."
::= { pmPowerMgmtPDUTableEntry 70 }
pmPowerMgmtPDUTableVoltageMax OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum value of voltage in the PDU (V).
Returns 0 if not supported."
::= { pmPowerMgmtPDUTableEntry 71 }
pmPowerMgmtPDUTableVoltageMin OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Minimum value of voltage in the PDU (V).
Returns 0 if not supported."
::= { pmPowerMgmtPDUTableEntry 72 }
pmPowerMgmtPDUTableVoltageAvg OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average value of voltage in the PDU (V).
Returns 0 if not supported."
::= { pmPowerMgmtPDUTableEntry 73 }
pmPowerMgmtPDUTableVoltageReset OBJECT-TYPE
SYNTAX INTEGER {
noAction(1),
reset(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"noAction(1) = always returned in a GET. Does nothing if SET.
reset(2) = when SET the reset command is sent to PDU."
::= { pmPowerMgmtPDUTableEntry 74 }
pmPowerMgmtPDUTableVoltageType OBJECT-TYPE
SYNTAX INTEGER {
none-sensor (0),
estimated (1),
measured (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Type of voltage values.
Returns 0 if not supported."
::= { pmPowerMgmtPDUTableEntry 75 }
pmPowerMgmtPDUTablePowerFactorValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Actual value of power factor in the PDU (Pf x 100).
Returns 0 if not supported."
::= { pmPowerMgmtPDUTableEntry 80 }
pmPowerMgmtPDUTablePowerFactorMax OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum value of power factor in the PDU (Pf x 100).
Returns 0 if not supported."
::= { pmPowerMgmtPDUTableEntry 81 }
pmPowerMgmtPDUTablePowerFactorMin OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Minimum value of power factor in the PDU (Pf x 100).
Returns 0 if not supported."
::= { pmPowerMgmtPDUTableEntry 82 }
pmPowerMgmtPDUTablePowerFactorAvg OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average value of power factor in the PDU (Pf x 100).
Returns 0 if not supported."
::= { pmPowerMgmtPDUTableEntry 83 }
pmPowerMgmtPDUTablePowerFactorReset OBJECT-TYPE
SYNTAX INTEGER {
noAction(1),
reset(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"noAction(1) = always returned in a GET. Does nothing if SET.
reset(2) = when SET the reset command is sent to PDU."
::= { pmPowerMgmtPDUTableEntry 84 }
pmPowerMgmtPDUTablePowerFactorType OBJECT-TYPE
SYNTAX INTEGER {
none-sensor (0),
estimated (1),
measured (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Type of power values.
Returns 0 if not supported."
::= { pmPowerMgmtPDUTableEntry 85 }
pmPowerMgmtPDUTablePowerControl OBJECT-TYPE
SYNTAX INTEGER {
noAction(1),
powerOn(2),
powerOff(3),
powerCycle(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A set value of power*(2-4) will send command to PDU.
noAction(1) = always returned in a GET. Does nothing if SET.
powerOn(2) = when SET the power On command is sent to PDU.
powerOff(3) = when SET the power Off command is sent to PDU.
powerCycle(4)=when SET the power cycle command is sent to PDU.
Returns 0 if not supported."
::= { pmPowerMgmtPDUTableEntry 90 }
pmPowerMgmtPDUTableResetOCP OBJECT-TYPE
SYNTAX INTEGER {
noAction(1),
reset(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A set value of power*(2) will send command to PDU.
noAction(1) = always returned in a GET. Does nothing if SET.
reset(2) = when SET the reset command is sent to PDU.
Returns 0 if not supported."
::= { pmPowerMgmtPDUTableEntry 91 }
pmPowerMgmtPDUTableCurrentHighCritical OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"outlet high critical (alarm) current threshold (A x 10).
Set fails if value is lower that CurrentHighWarning.
Returns 0 if not supported."
::= { pmPowerMgmtPDUTableEntry 100 }
pmPowerMgmtPDUTableCurrentHighWarning OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"outlet high warning current threshold (A x 10).
Set fails if value is higher than CurrentHighCritical or lower than CurrentLowWarning.
Returns 0 if not supported."
::= { pmPowerMgmtPDUTableEntry 101 }
pmPowerMgmtPDUTableCurrentLowWarning OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"outlet low warning current threshold (A x 10).
Set fails if value is higher than CurrentHighWarning or lower than CurrentLowCritical.
Returns 0 if not supported."
::= { pmPowerMgmtPDUTableEntry 102 }
pmPowerMgmtPDUTableCurrentLowCritical OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"outlet low critical current threshold (A x 10).
Set fails if value is higher than CurrentLowWarning.
Returns 0 if not supported."
::= { pmPowerMgmtPDUTableEntry 103 }
pmPowerMgmtPDUTableEnergyValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"pdu energy value (Wh).
Returns 0 if not supported."
::= { pmPowerMgmtPDUTableEntry 105 }
pmPowerMgmtPDUTableEnergyStartTime OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"time at which energy calculation commenced (ISO8601 format).
Returns N/A if not applicable."
::= { pmPowerMgmtPDUTableEntry 106 }
pmPowerMgmtPDUTableEnergyReset OBJECT-TYPE
SYNTAX INTEGER {
noAction(1),
reset(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"noAction(1) = always returned in a GET. Does nothing if SET.
reset(2) = when SET the reset command is sent to PDU."
::= { pmPowerMgmtPDUTableEntry 107 }
pmPowerMgmtTotalNumberOfOutlets OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of outlets managed by the appliance."
::= { pmPowerMgmt 4 }
pmPowerMgmtOutletsTable OBJECT-TYPE
SYNTAX SEQUENCE OF PmPowerMgmtOutletsTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the information about outlets."
::= { pmPowerMgmt 5 }
pmPowerMgmtOutletsTableEntry OBJECT-TYPE
SYNTAX PmPowerMgmtOutletsTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"each entry has the information about the outlet."
INDEX { pmPowerMgmtOutletsTablePortNumber,
pmPowerMgmtOutletsTablePduNumber,
pmPowerMgmtOutletsTableNumber }
::= { pmPowerMgmtOutletsTable 1 }
PmPowerMgmtOutletsTableEntry ::= SEQUENCE {
pmPowerMgmtOutletsTablePortNumber InterfaceIndex, -- serial port #
pmPowerMgmtOutletsTablePduNumber InterfaceIndex,
pmPowerMgmtOutletsTableNumber InterfaceIndex, -- outlet number in PDU
pmPowerMgmtOutletsTableName DisplayString, -- outlet name
pmPowerMgmtOutletsTableStatus INTEGER, -- outlet status
pmPowerMgmtOutletsTablePowerControl INTEGER, -- manage the outlet
pmPowerMgmtOutletsTablePortName DisplayString, -- serial port name
pmPowerMgmtOutletsTablePduId DisplayString, -- PDU ID
pmPowerMgmtOutletsTablePostOnDelay Integer32, -- outlet post on delay delay/post power on
pmPowerMgmtOutletsTablePostOffDelay Integer32, -- outlet post off delay/post power off
pmPowerMgmtOutletsTableAlarm INTEGER, -- outlet alarm status
pmPowerMgmtOutletsTableCurrentValue Integer32, -- actual value for current of the sensor
pmPowerMgmtOutletsTableCurrentMax Integer32, -- max value for current
pmPowerMgmtOutletsTableCurrentMin Integer32, -- min value for current
pmPowerMgmtOutletsTableCurrentAvg Integer32, -- average value for current
pmPowerMgmtOutletsTableCurrentReset INTEGER, -- reset the current stats
pmPowerMgmtOutletsTablePowerValue Integer32, -- actual value for power
pmPowerMgmtOutletsTablePowerMax Integer32, -- max value for power
pmPowerMgmtOutletsTablePowerMin Integer32, -- min value for power
pmPowerMgmtOutletsTablePowerAvg Integer32, -- average value for power
pmPowerMgmtOutletsTablePowerReset INTEGER, -- reset the power stats
pmPowerMgmtOutletsTablePowerType INTEGER, -- power type
pmPowerMgmtOutletsTableVoltageValue Integer32, -- actual value for voltage
pmPowerMgmtOutletsTableVoltageMax Integer32, -- max value for voltage
pmPowerMgmtOutletsTableVoltageMin Integer32, -- min value for voltage
pmPowerMgmtOutletsTableVoltageAvg Integer32, -- average value for voltage
pmPowerMgmtOutletsTableVoltageReset INTEGER, -- reset the voltage stats
pmPowerMgmtOutletsTableVoltageType INTEGER, -- type of voltage measurement
pmPowerMgmtOutletsTablePowerFactorValue Integer32, -- actual value for powerfactor
pmPowerMgmtOutletsTablePowerFactorMax Integer32, -- max value for powerfactor
pmPowerMgmtOutletsTablePowerFactorMin Integer32, -- min value for powerfactor
pmPowerMgmtOutletsTablePowerFactorAvg Integer32, -- average value for powerfactor
pmPowerMgmtOutletsTablePowerFactorReset INTEGER, -- reset the powerfactor stats
pmPowerMgmtOutletsTablePowerFactorType INTEGER, -- power factor type
pmPowerMgmtOutletsTableCurrentHighCritical Integer32, -- outlet current high critical threshold
pmPowerMgmtOutletsTableCurrentHighWarning Integer32, -- outlet current high warning threshold
pmPowerMgmtOutletsTableCurrentLowWarning Integer32, -- outlet current low warning threshold
pmPowerMgmtOutletsTableCurrentLowCritical Integer32, -- outlet current low critical threshold
pmPowerMgmtOutletsTableEnergyValue Integer32, -- Energy value
pmPowerMgmtOutletsTableEnergyStartTime DisplayString, -- time at which energy calculation commenced
pmPowerMgmtOutletsTableEnergyReset INTEGER -- reset energy calculation and start time to now
}
pmPowerMgmtOutletsTablePortNumber OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Serial Port number."
::= { pmPowerMgmtOutletsTableEntry 1 }
pmPowerMgmtOutletsTablePduNumber OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index."
::= { pmPowerMgmtOutletsTableEntry 2 }
pmPowerMgmtOutletsTableNumber OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of the outlet in the PDU."
::= { pmPowerMgmtOutletsTableEntry 3 }
pmPowerMgmtOutletsTableName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Name of the outlet."
::= { pmPowerMgmtOutletsTableEntry 4 }
pmPowerMgmtOutletsTableStatus OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
offLocked(3),
onLocked(4),
offCycle(5),
onPendingOff(6),
offPendingOn(7),
onPendingCycle(8),
notSet(9),
onFixed(10),
offShutdown(11),
tripped(12)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of the outlet.
Returns 0 if not supported."
::= { pmPowerMgmtOutletsTableEntry 5 }
pmPowerMgmtOutletsTablePowerControl OBJECT-TYPE
SYNTAX INTEGER {
noAction(1),
powerOn(2),
powerOff(3),
powerCycle(4),
powerLock(5),
powerUnlock(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A set value of power*(2-6) will send command to PDU.
noAction(1) = always returned in a GET. Does nothing if SET.
powerOn(2) = when SET the power On command is sent to PDU.
powerOff(3) = when SET the power Off command is sent to PDU.
powerCycle(4)=when SET the power cycle command is sent to PDU.
powerLock(5)= when SET the power lock command is sent to PDU.
powerUnlock(6)=when SET the power unlock command is sent to PDU.
The powerLock and powerUnlock are valid only for Cyclades-PM PDUs"
::= { pmPowerMgmtOutletsTableEntry 6 }
pmPowerMgmtOutletsTablePortName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Serial Port Name where the PDU is connected."
::= { pmPowerMgmtOutletsTableEntry 7 }
pmPowerMgmtOutletsTablePduId OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PDU identification."
::= { pmPowerMgmtOutletsTableEntry 8 }
pmPowerMgmtOutletsTablePostOnDelay OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"post on delay for the outlet (seconds x 10)
Returns 0 if not supported."
::= { pmPowerMgmtOutletsTableEntry 9 }
pmPowerMgmtOutletsTablePostOffDelay OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"post off delay for the outlet (seconds x 10)
Returns 0 if not supported."
::= { pmPowerMgmtOutletsTableEntry 10 }
pmPowerMgmtOutletsTableAlarm OBJECT-TYPE
SYNTAX INTEGER {
normal (1),
blow-fuse (2),
hw-ocp (3),
high-critical (4),
high-warning (5),
low-warning (6),
low-critical (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Show the outlet alarm status.
Returns 0 if not supported."
::= { pmPowerMgmtOutletsTableEntry 45 }
--@ Note: Intentionally left space for future expansion
pmPowerMgmtOutletsTableCurrentValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Actual value of current in the outlet (A x 10).
Returns 0 if not supported."
::= { pmPowerMgmtOutletsTableEntry 50 }
pmPowerMgmtOutletsTableCurrentMax OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum value of current in the outlet (A x 10).
Returns 0 if not supported."
::= { pmPowerMgmtOutletsTableEntry 51 }
pmPowerMgmtOutletsTableCurrentMin OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Minimum value of current in the outlet (A x 10).
Returns 0 if not supported."
::= { pmPowerMgmtOutletsTableEntry 52 }
pmPowerMgmtOutletsTableCurrentAvg OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average value of current in the outlet (A x 10).
Returns 0 if not supported."
::= { pmPowerMgmtOutletsTableEntry 53 }
pmPowerMgmtOutletsTableCurrentReset OBJECT-TYPE
SYNTAX INTEGER {
noAction(1),
reset(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"noAction(1) = always returned in a GET. Does nothing if SET.
reset(2) = when SET the reset command is sent to PDU."
::= { pmPowerMgmtOutletsTableEntry 54 }
pmPowerMgmtOutletsTablePowerValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Actual value of power in the outlet (W x 10).
Returns 0 if not supported."
::= { pmPowerMgmtOutletsTableEntry 60 }
pmPowerMgmtOutletsTablePowerMax OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum value of power in the outlet (W x 10).
Returns 0 if not supported."
::= { pmPowerMgmtOutletsTableEntry 61 }
pmPowerMgmtOutletsTablePowerMin OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Minimum value of power in the outlet (W x 10).
Returns 0 if not supported."
::= { pmPowerMgmtOutletsTableEntry 62 }
pmPowerMgmtOutletsTablePowerAvg OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average value of power in the outlet (W x 10).
Returns 0 if not supported."
::= { pmPowerMgmtOutletsTableEntry 63 }
pmPowerMgmtOutletsTablePowerReset OBJECT-TYPE
SYNTAX INTEGER {
noAction(1),
reset(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"noAction(1) = always returned in a GET. Does nothing if SET.
reset(2) = when SET the reset command is sent to PDU."
::= { pmPowerMgmtOutletsTableEntry 64 }
pmPowerMgmtOutletsTablePowerType OBJECT-TYPE
SYNTAX INTEGER {
none-sensor (0),
estimated (1),
measured (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Type of power values.
Returns 0 if not supported."
::= { pmPowerMgmtOutletsTableEntry 65 }
pmPowerMgmtOutletsTableVoltageValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Actual value of voltage in the outlet (V).
Returns 0 if not supported."
::= { pmPowerMgmtOutletsTableEntry 70 }
pmPowerMgmtOutletsTableVoltageMax OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum value of voltage in the outlet (V).
Returns 0 if not supported."
::= { pmPowerMgmtOutletsTableEntry 71 }
pmPowerMgmtOutletsTableVoltageMin OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Minimum value of voltage in the outlet (V).
Returns 0 if not supported."
::= { pmPowerMgmtOutletsTableEntry 72 }
pmPowerMgmtOutletsTableVoltageAvg OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average value of voltage in the outlet (V).
Returns 0 if not supported."
::= { pmPowerMgmtOutletsTableEntry 73 }
pmPowerMgmtOutletsTableVoltageReset OBJECT-TYPE
SYNTAX INTEGER {
noAction(1),
reset(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"noAction(1) = always returned in a GET. Does nothing if SET.
reset(2) = when SET the reset command is sent to PDU."
::= { pmPowerMgmtOutletsTableEntry 74 }
pmPowerMgmtOutletsTableVoltageType OBJECT-TYPE
SYNTAX INTEGER {
none-sensor (0),
estimated (1),
measured (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Type of voltage values.
Returns 0 if not supported."
::= { pmPowerMgmtOutletsTableEntry 75 }
pmPowerMgmtOutletsTablePowerFactorValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Actual value of power factor in the outlet (Pf x 100).
Returns 0 if not supported."
::= { pmPowerMgmtOutletsTableEntry 80 }
pmPowerMgmtOutletsTablePowerFactorMax OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum value of power factor in the outlet (Pf x 100).
Returns 0 if not supported."
::= { pmPowerMgmtOutletsTableEntry 81 }
pmPowerMgmtOutletsTablePowerFactorMin OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Minimum value of power factor in the outlet (Pf x 100).
Returns 0 if not supported."
::= { pmPowerMgmtOutletsTableEntry 82 }
pmPowerMgmtOutletsTablePowerFactorAvg OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average value of power factor in the outlet (Pf x 100).
Returns 0 if not supported."
::= { pmPowerMgmtOutletsTableEntry 83 }
pmPowerMgmtOutletsTablePowerFactorReset OBJECT-TYPE
SYNTAX INTEGER {
noAction(1),
reset(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"noAction(1) = always returned in a GET. Does nothing if SET.
reset(2) = when SET the reset command is sent to PDU."
::= { pmPowerMgmtOutletsTableEntry 84 }
pmPowerMgmtOutletsTablePowerFactorType OBJECT-TYPE
SYNTAX INTEGER {
none-sensor (0),
estimated (1),
measured (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Type of power factor values.
Returns 0 if not supported."
::= { pmPowerMgmtOutletsTableEntry 85 }
pmPowerMgmtOutletsTableCurrentHighCritical OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"outlet high critical (alarm) current threshold (A x 10).
Set fails if value is lower that CurrentHighWarning.
Returns 0 if not supported."
::= { pmPowerMgmtOutletsTableEntry 100 }
pmPowerMgmtOutletsTableCurrentHighWarning OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"outlet high warning current threshold (A x 10).
Set fails if value is higher than CurrentHighCritical or lower than CurrentLowWarning.
Returns 0 if not supported."
::= { pmPowerMgmtOutletsTableEntry 101 }
pmPowerMgmtOutletsTableCurrentLowWarning OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"outlet low warning current threshold (A x 10).
Set fails if value is higher than CurrentHighWarning or lower than CurrentLowCritical.
Returns 0 if not supported."
::= { pmPowerMgmtOutletsTableEntry 102 }
pmPowerMgmtOutletsTableCurrentLowCritical OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"outlet low critical current threshold (A x 10).
Set fails if value is higher than CurrentLowWarning.
Returns 0 if not supported."
::= { pmPowerMgmtOutletsTableEntry 103 }
pmPowerMgmtOutletsTableEnergyValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"outlet energy value (Wh).
Returns 0 if not supported."
::= { pmPowerMgmtOutletsTableEntry 105 }
pmPowerMgmtOutletsTableEnergyStartTime OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"time at which energy calculation commenced (ISO8601 format).
Returns N/A if not applicable."
::= { pmPowerMgmtOutletsTableEntry 106 }
pmPowerMgmtOutletsTableEnergyReset OBJECT-TYPE
SYNTAX INTEGER {
noAction(1),
reset(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"noAction(1) = always returned in a GET. Does nothing if SET.
reset(2) = when SET the reset command is sent to PDU."
::= { pmPowerMgmtOutletsTableEntry 107 }
pmPowerMgmtNumberOfOutletGroup OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of configured group of outlets."
::= { pmPowerMgmt 6 }
pmPowerMgmtGroupTable OBJECT-TYPE
SYNTAX SEQUENCE OF PmPowerMgmtGroupTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the information about group of outlets."
::= { pmPowerMgmt 7 }
pmPowerMgmtGroupTableEntry OBJECT-TYPE
SYNTAX PmPowerMgmtGroupTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"each entry has the information about group of outlets."
INDEX { pmPowerMgmtGroupTableIndex }
::= { pmPowerMgmtGroupTable 1 }
PmPowerMgmtGroupTableEntry ::= SEQUENCE {
pmPowerMgmtGroupTableIndex InterfaceIndexOrZero,
pmPowerMgmtGroupTableName DisplayString, -- group name
pmPowerMgmtGroupTableStatus INTEGER, -- group status
pmPowerMgmtGroupTablePowerControl INTEGER -- manage the group
}
pmPowerMgmtGroupTableIndex OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index of the group."
::= { pmPowerMgmtGroupTableEntry 1 }
pmPowerMgmtGroupTableName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Name of the group of outlets."
::= { pmPowerMgmtGroupTableEntry 2 }
pmPowerMgmtGroupTableStatus OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of the group of outlet."
::= { pmPowerMgmtGroupTableEntry 3 }
pmPowerMgmtGroupTablePowerControl OBJECT-TYPE
SYNTAX INTEGER {
noAction(1),
powerOn(2),
powerOff(3),
powerCycle(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A set value of power*(2-4) will send command to PDU.
noAction(1) = always returned in a GET. Does nothing if SET.
powerOn(2) = when SET the power On command is sent to PDU.
powerOff(3) = when SET the power Off command is sent to PDU.
powerCycle(4)=when SET the power cycle command is sent to PDU."
::= { pmPowerMgmtGroupTableEntry 4 }
pmPowerMgmtTotalNumberOfPhases OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of phases managed by the appliance."
::= { pmPowerMgmt 8 }
pmPowerMgmtPhasesTable OBJECT-TYPE
SYNTAX SEQUENCE OF PmPowerMgmtPhasesTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the information about phases."
::= { pmPowerMgmt 9 }
pmPowerMgmtPhasesTableEntry OBJECT-TYPE
SYNTAX PmPowerMgmtPhasesTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"each entry has the information about the phases."
INDEX { pmPowerMgmtPhasesTablePortNumber,
pmPowerMgmtPhasesTablePduNumber,
pmPowerMgmtPhasesTableNumber }
::= { pmPowerMgmtPhasesTable 1 }
PmPowerMgmtPhasesTableEntry ::= SEQUENCE {
pmPowerMgmtPhasesTablePortNumber InterfaceIndex, -- serial port #
pmPowerMgmtPhasesTablePduNumber InterfaceIndex,
pmPowerMgmtPhasesTableNumber InterfaceIndex, -- phase number in PDU
pmPowerMgmtPhasesTableName DisplayString, -- phase sysname
pmPowerMgmtPhasesTablePortName DisplayString, -- serial port name
pmPowerMgmtPhasesTablePduId DisplayString, -- PDU ID
pmPowerMgmtPhasesTableAlarm INTEGER, -- phase alarm status
pmPowerMgmtPhasesTableCurrentValue Integer32, -- actual value for current of the sensor
pmPowerMgmtPhasesTableCurrentMax Integer32, -- max value for current
pmPowerMgmtPhasesTableCurrentMin Integer32, -- min value for current
pmPowerMgmtPhasesTableCurrentAvg Integer32, -- average value for current
pmPowerMgmtPhasesTableCurrentReset INTEGER, -- reset the current stats
pmPowerMgmtPhasesTablePowerValue Integer32, -- actual value for power
pmPowerMgmtPhasesTablePowerMax Integer32, -- max value for power
pmPowerMgmtPhasesTablePowerMin Integer32, -- min value for power
pmPowerMgmtPhasesTablePowerAvg Integer32, -- average value for power
pmPowerMgmtPhasesTablePowerReset INTEGER, -- reset the power stats
pmPowerMgmtPhasesTablePowerType INTEGER, -- power type
pmPowerMgmtPhasesTableVoltageValue Integer32, -- actual value for voltage
pmPowerMgmtPhasesTableVoltageMax Integer32, -- max value for voltage
pmPowerMgmtPhasesTableVoltageMin Integer32, -- min value for voltage
pmPowerMgmtPhasesTableVoltageAvg Integer32, -- average value for voltage
pmPowerMgmtPhasesTableVoltageReset INTEGER, -- reset the voltage stats
pmPowerMgmtPhasesTableVoltageType INTEGER, -- voltage type
pmPowerMgmtPhasesTablePowerFactorValue Integer32, -- actual value for powerfactor
pmPowerMgmtPhasesTablePowerFactorMax Integer32, -- max value for powerfactor
pmPowerMgmtPhasesTablePowerFactorMin Integer32, -- min value for powerfactor
pmPowerMgmtPhasesTablePowerFactorAvg Integer32, -- average value for powerfactor
pmPowerMgmtPhasesTablePowerFactorReset INTEGER, -- reset the powerfactor stats
pmPowerMgmtPhasesTablePowerFactorType INTEGER, -- power factor type
pmPowerMgmtPhasesTableCurrentHighCritical Integer32, -- outlet current high critical threshold
pmPowerMgmtPhasesTableCurrentHighWarning Integer32, -- outlet current high warning threshold
pmPowerMgmtPhasesTableCurrentLowWarning Integer32, -- outlet current low warning threshold
pmPowerMgmtPhasesTableCurrentLowCritical Integer32 -- outlet current low critical threshold
}
pmPowerMgmtPhasesTablePortNumber OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Serial Port number."
::= { pmPowerMgmtPhasesTableEntry 1 }
pmPowerMgmtPhasesTablePduNumber OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index."
::= { pmPowerMgmtPhasesTableEntry 2 }
pmPowerMgmtPhasesTableNumber OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of the phase in the PDU."
::= { pmPowerMgmtPhasesTableEntry 3 }
pmPowerMgmtPhasesTableName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Name of the phase.
Returns N/A if not applicable."
::= { pmPowerMgmtPhasesTableEntry 4 }
pmPowerMgmtPhasesTablePortName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Serial Port Name where the PDU is connected."
::= { pmPowerMgmtPhasesTableEntry 5 }
pmPowerMgmtPhasesTablePduId OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PDU identification."
::= { pmPowerMgmtPhasesTableEntry 6 }
pmPowerMgmtPhasesTableAlarm OBJECT-TYPE
SYNTAX INTEGER {
normal (1),
blow-fuse (2),
hw-ocp (3),
high-critical (4),
high-warning (5),
low-warning (6),
low-critical (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Show the phase alarm status.
Returns 0 if not supported."
::= { pmPowerMgmtPhasesTableEntry 45 }
--@ Note: Intentionally left space for future expansion
pmPowerMgmtPhasesTableCurrentValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Actual value of current in the phase (A x 10).
Returns 0 if not supported."
::= { pmPowerMgmtPhasesTableEntry 50 }
pmPowerMgmtPhasesTableCurrentMax OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum value of current in the phase (A x 10).
Returns 0 if not supported."
::= { pmPowerMgmtPhasesTableEntry 51 }
pmPowerMgmtPhasesTableCurrentMin OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Minimum value of current in the phase (A x 10).
Returns 0 if not supported."
::= { pmPowerMgmtPhasesTableEntry 52 }
pmPowerMgmtPhasesTableCurrentAvg OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average value of current in the phase (A x 10).
Returns 0 if not supported."
::= { pmPowerMgmtPhasesTableEntry 53 }
pmPowerMgmtPhasesTableCurrentReset OBJECT-TYPE
SYNTAX INTEGER {
noAction(1),
reset(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"noAction(1) = always returned in a GET. Does nothing if SET.
reset(2) = when SET the reset command is sent to PDU."
::= { pmPowerMgmtPhasesTableEntry 54 }
pmPowerMgmtPhasesTablePowerValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Actual value of power in the phase (W x 10).
Returns 0 if not supported."
::= { pmPowerMgmtPhasesTableEntry 60 }
pmPowerMgmtPhasesTablePowerMax OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum value of power in the phase (W x 10).
Returns 0 if not supported."
::= { pmPowerMgmtPhasesTableEntry 61 }
pmPowerMgmtPhasesTablePowerMin OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Minimum value of power in the phase (W x 10).
Returns 0 if not supported."
::= { pmPowerMgmtPhasesTableEntry 62 }
pmPowerMgmtPhasesTablePowerAvg OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average value of power in the phase (W x 10).
Returns 0 if not supported."
::= { pmPowerMgmtPhasesTableEntry 63 }
pmPowerMgmtPhasesTablePowerReset OBJECT-TYPE
SYNTAX INTEGER {
noAction(1),
reset(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"noAction(1) = always returned in a GET. Does nothing if SET.
reset(2) = when SET the reset command is sent to PDU."
::= { pmPowerMgmtPhasesTableEntry 64 }
pmPowerMgmtPhasesTablePowerType OBJECT-TYPE
SYNTAX INTEGER {
none-sensor (0),
estimated (1),
measured (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Type of power values.
Returns 0 if not supported."
::= { pmPowerMgmtPhasesTableEntry 65 }
pmPowerMgmtPhasesTableVoltageValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Actual value of voltage in the phase (V).
Returns 0 if not supported."
::= { pmPowerMgmtPhasesTableEntry 70 }
pmPowerMgmtPhasesTableVoltageMax OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum value of voltage in the phase (V).
Returns 0 if not supported."
::= { pmPowerMgmtPhasesTableEntry 71 }
pmPowerMgmtPhasesTableVoltageMin OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Minimum value of voltage in the phase (V).
Returns 0 if not supported."
::= { pmPowerMgmtPhasesTableEntry 72 }
pmPowerMgmtPhasesTableVoltageAvg OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average value of voltage in the phase (V).
Returns 0 if not supported."
::= { pmPowerMgmtPhasesTableEntry 73 }
pmPowerMgmtPhasesTableVoltageReset OBJECT-TYPE
SYNTAX INTEGER {
noAction(1),
reset(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"noAction(1) = always returned in a GET. Does nothing if SET.
reset(2) = when SET the reset command is sent to PDU."
::= { pmPowerMgmtPhasesTableEntry 74 }
pmPowerMgmtPhasesTableVoltageType OBJECT-TYPE
SYNTAX INTEGER {
none-sensor (0),
estimated (1),
measured (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Type of voltage values.
Returns 0 if not supported."
::= { pmPowerMgmtPhasesTableEntry 75 }
pmPowerMgmtPhasesTablePowerFactorValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Actual value of power factor in the phase (Pf x 100).
Returns 0 if not supported."
::= { pmPowerMgmtPhasesTableEntry 80 }
pmPowerMgmtPhasesTablePowerFactorMax OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum value of power factor in the phase (Pf x 100).
Returns 0 if not supported."
::= { pmPowerMgmtPhasesTableEntry 81 }
pmPowerMgmtPhasesTablePowerFactorMin OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Minimum value of power factor in the phase (Pf x 100).
Returns 0 if not supported."
::= { pmPowerMgmtPhasesTableEntry 82 }
pmPowerMgmtPhasesTablePowerFactorAvg OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average value of power factor in the phase (Pf x 100).
Returns 0 if not supported."
::= { pmPowerMgmtPhasesTableEntry 83 }
pmPowerMgmtPhasesTablePowerFactorReset OBJECT-TYPE
SYNTAX INTEGER {
noAction(1),
reset(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"noAction(1) = always returned in a GET. Does nothing if SET.
reset(2) = when SET the reset command is sent to PDU."
::= { pmPowerMgmtPhasesTableEntry 84 }
pmPowerMgmtPhasesTablePowerFactorType OBJECT-TYPE
SYNTAX INTEGER {
none-sensor (0),
estimated (1),
measured (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Type of power factor values.
Returns 0 if not supported."
::= { pmPowerMgmtPhasesTableEntry 85 }
pmPowerMgmtPhasesTableCurrentHighCritical OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"phase high critical (alarm) current threshold (A x 10).
Set fails if value is lower that CurrentHighWarning.
Returns 0 if not supported."
::= { pmPowerMgmtPhasesTableEntry 100 }
pmPowerMgmtPhasesTableCurrentHighWarning OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"phase high warning current threshold (A x 10).
Set fails if value is higher than CurrentHighCritical or lower than CurrentLowWarning.
Returns 0 if not supported."
::= { pmPowerMgmtPhasesTableEntry 101 }
pmPowerMgmtPhasesTableCurrentLowWarning OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"phase low warning current threshold (A x 10).
Set fails if value is higher than CurrentHighWarning or lower than CurrentLowCritical.
Returns 0 if not supported."
::= { pmPowerMgmtPhasesTableEntry 102 }
pmPowerMgmtPhasesTableCurrentLowCritical OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"phase low critical current threshold (A x 10).
Set fails if value is higher than CurrentLowWarning.
Returns 0 if not supported."
::= { pmPowerMgmtPhasesTableEntry 103 }
--@ BANKS
pmPowerMgmtTotalNumberOfBanks OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of banks managed by the appliance."
::= { pmPowerMgmt 10 }
pmPowerMgmtBanksTable OBJECT-TYPE
SYNTAX SEQUENCE OF PmPowerMgmtBanksTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the information about banks."
::= { pmPowerMgmt 11 }
pmPowerMgmtBanksTableEntry OBJECT-TYPE
SYNTAX PmPowerMgmtBanksTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"each entry has the information about the banks."
INDEX { pmPowerMgmtBanksTablePortNumber,
pmPowerMgmtBanksTablePduNumber,
pmPowerMgmtBanksTableNumber }
::= { pmPowerMgmtBanksTable 1 }
PmPowerMgmtBanksTableEntry ::= SEQUENCE {
pmPowerMgmtBanksTablePortNumber InterfaceIndex, -- serial port #
pmPowerMgmtBanksTablePduNumber InterfaceIndex,
pmPowerMgmtBanksTableNumber InterfaceIndex, -- bank number in PDU
pmPowerMgmtBanksTableName DisplayString, -- bank sysname
pmPowerMgmtBanksTablePortName DisplayString, -- serial port name
pmPowerMgmtBanksTablePduId DisplayString, -- PDU ID
pmPowerMgmtBanksTableAlarm INTEGER, -- bank alarm status
pmPowerMgmtBanksTableCurrentValue Integer32, -- actual value for current of the sensor
pmPowerMgmtBanksTableCurrentMax Integer32, -- max value for current
pmPowerMgmtBanksTableCurrentMin Integer32, -- min value for current
pmPowerMgmtBanksTableCurrentAvg Integer32, -- average value for current
pmPowerMgmtBanksTableCurrentReset INTEGER, -- reset current stats
pmPowerMgmtBanksTablePowerValue Integer32, -- actual value for power
pmPowerMgmtBanksTablePowerMax Integer32, -- max value for power
pmPowerMgmtBanksTablePowerMin Integer32, -- min value for power
pmPowerMgmtBanksTablePowerAvg Integer32, -- average value for power
pmPowerMgmtBanksTablePowerReset INTEGER, -- reset power stats
pmPowerMgmtBanksTablePowerType INTEGER, -- power type
pmPowerMgmtBanksTableVoltageValue Integer32, -- actual value for voltage
pmPowerMgmtBanksTableVoltageMax Integer32, -- max value for voltage
pmPowerMgmtBanksTableVoltageMin Integer32, -- min value for voltage
pmPowerMgmtBanksTableVoltageAvg Integer32, -- average value for voltage
pmPowerMgmtBanksTableVoltageReset INTEGER, -- reset voltage stats
pmPowerMgmtBanksTableVoltageType INTEGER, -- voltage type
pmPowerMgmtBanksTablePowerFactorValue Integer32, -- actual value for powerfactor
pmPowerMgmtBanksTablePowerFactorMax Integer32, -- max value for powerfactor
pmPowerMgmtBanksTablePowerFactorMin Integer32, -- min value for powerfactor
pmPowerMgmtBanksTablePowerFactorAvg Integer32, -- average value for powerfactor
pmPowerMgmtBanksTablePowerFactorReset INTEGER, -- reset powerfactor stats
pmPowerMgmtBanksTablePowerFactorType INTEGER, -- power factor type
pmPowerMgmtBanksTableCurrentHighCritical Integer32, -- outlet current high critical threshold
pmPowerMgmtBanksTableCurrentHighWarning Integer32, -- outlet current high warning threshold
pmPowerMgmtBanksTableCurrentLowWarning Integer32, -- outlet current low warning threshold
pmPowerMgmtBanksTableCurrentLowCritical Integer32, -- outlet current low critical threshold
pmPowerMgmtBanksTableEnergyValue Integer32, -- Energy value
pmPowerMgmtBanksTableEnergyStartTime DisplayString, -- time at which energy calculation commenced
pmPowerMgmtBanksTableEnergyReset INTEGER -- reset energy calculation and start time to now
}
pmPowerMgmtBanksTablePortNumber OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Serial Port number."
::= { pmPowerMgmtBanksTableEntry 1 }
pmPowerMgmtBanksTablePduNumber OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index."
::= { pmPowerMgmtBanksTableEntry 2 }
pmPowerMgmtBanksTableNumber OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of the bank in the PDU."
::= { pmPowerMgmtBanksTableEntry 3 }
pmPowerMgmtBanksTableName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Name of the bank."
::= { pmPowerMgmtBanksTableEntry 4 }
pmPowerMgmtBanksTablePortName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Serial Port Name where the PDU is connected."
::= { pmPowerMgmtBanksTableEntry 5 }
pmPowerMgmtBanksTablePduId OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PDU identification."
::= { pmPowerMgmtBanksTableEntry 6 }
pmPowerMgmtBanksTableAlarm OBJECT-TYPE
SYNTAX INTEGER {
normal (1),
blow-fuse (2),
hw-ocp (3),
high-critical (4),
high-warning (5),
low-warning (6),
low-critical (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Show the bank alarm status.
Returns 0 if not supported."
::= { pmPowerMgmtBanksTableEntry 45 }
--@ Note: Intentionally left space for future expansion
pmPowerMgmtBanksTableCurrentValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Actual value of current in the bank (A x 10).
Returns 0 if not supported."
::= { pmPowerMgmtBanksTableEntry 50 }
pmPowerMgmtBanksTableCurrentMax OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum value of current in the bank (A x 10).
Returns 0 if not supported."
::= { pmPowerMgmtBanksTableEntry 51 }
pmPowerMgmtBanksTableCurrentMin OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Minimum value of current in the bank (A x 10).
Returns 0 if not supported."
::= { pmPowerMgmtBanksTableEntry 52 }
pmPowerMgmtBanksTableCurrentAvg OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average value of current in the bank (A x 10).
Returns 0 if not supported."
::= { pmPowerMgmtBanksTableEntry 53 }
pmPowerMgmtBanksTableCurrentReset OBJECT-TYPE
SYNTAX INTEGER {
noAction(1),
reset(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"noAction(1) = always returned in a GET. Does nothing if SET.
reset(2) = when SET the reset command is sent to PDU."
::= { pmPowerMgmtBanksTableEntry 54 }
pmPowerMgmtBanksTablePowerValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Actual value of power in the bank (W x 10).
Returns 0 if not supported."
::= { pmPowerMgmtBanksTableEntry 60 }
pmPowerMgmtBanksTablePowerMax OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum value of power in the bank (W x 10).
Returns 0 if not supported."
::= { pmPowerMgmtBanksTableEntry 61 }
pmPowerMgmtBanksTablePowerMin OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Minimum value of power in the bank (W x 10).
Returns 0 if not supported."
::= { pmPowerMgmtBanksTableEntry 62 }
pmPowerMgmtBanksTablePowerAvg OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average value of power in the bank (W x 10).
Returns 0 if not supported."
::= { pmPowerMgmtBanksTableEntry 63 }
pmPowerMgmtBanksTablePowerReset OBJECT-TYPE
SYNTAX INTEGER {
noAction(1),
reset(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"noAction(1) = always returned in a GET. Does nothing if SET.
reset(2) = when SET the reset command is sent to PDU."
::= { pmPowerMgmtBanksTableEntry 64 }
pmPowerMgmtBanksTablePowerType OBJECT-TYPE
SYNTAX INTEGER {
none-sensor (0),
estimated (1),
measured (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Type of power values.
Returns 0 if not supported."
::= { pmPowerMgmtBanksTableEntry 65 }
pmPowerMgmtBanksTableVoltageValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Actual value of voltage in the bank (V).
Returns 0 if not supported."
::= { pmPowerMgmtBanksTableEntry 70 }
pmPowerMgmtBanksTableVoltageMax OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum value of voltage in the bank (V).
Returns 0 if not supported."
::= { pmPowerMgmtBanksTableEntry 71 }
pmPowerMgmtBanksTableVoltageMin OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Minimum value of voltage in the bank (V).
Returns 0 if not supported."
::= { pmPowerMgmtBanksTableEntry 72 }
pmPowerMgmtBanksTableVoltageAvg OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average value of voltage in the bank (V).
Returns 0 if not supported."
::= { pmPowerMgmtBanksTableEntry 73 }
pmPowerMgmtBanksTableVoltageReset OBJECT-TYPE
SYNTAX INTEGER {
noAction(1),
reset(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"noAction(1) = always returned in a GET. Does nothing if SET.
reset(2) = when SET the reset command is sent to PDU."
::= { pmPowerMgmtBanksTableEntry 74 }
pmPowerMgmtBanksTableVoltageType OBJECT-TYPE
SYNTAX INTEGER {
none-sensor (0),
estimated (1),
measured (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Type of voltage values.
Returns 0 if not supported."
::= { pmPowerMgmtBanksTableEntry 75 }
pmPowerMgmtBanksTablePowerFactorValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Actual value of power factor in the bank (Pf x 100).
Returns 0 if not supported."
::= { pmPowerMgmtBanksTableEntry 80 }
pmPowerMgmtBanksTablePowerFactorMax OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum value of power factor in the bank (Pf x 100).
Returns 0 if not supported."
::= { pmPowerMgmtBanksTableEntry 81 }
pmPowerMgmtBanksTablePowerFactorMin OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Minimum value of power factor in the bank (Pf x 100).
Returns 0 if not supported."
::= { pmPowerMgmtBanksTableEntry 82 }
pmPowerMgmtBanksTablePowerFactorAvg OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average value of power factor in the bank (Pf x 100).
Returns 0 if not supported."
::= { pmPowerMgmtBanksTableEntry 83 }
pmPowerMgmtBanksTablePowerFactorReset OBJECT-TYPE
SYNTAX INTEGER {
noAction(1),
reset(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"noAction(1) = always returned in a GET. Does nothing if SET.
reset(2) = when SET the reset command is sent to PDU."
::= { pmPowerMgmtBanksTableEntry 84 }
pmPowerMgmtBanksTablePowerFactorType OBJECT-TYPE
SYNTAX INTEGER {
none-sensor (0),
estimated (1),
measured (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Type of power factor values.
Returns 0 if not supported."
::= { pmPowerMgmtBanksTableEntry 85 }
pmPowerMgmtBanksTableCurrentHighCritical OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"bank high critical (alarm) current threshold (A x 10).
Set fails if value is lower that CurrentHighWarning.
Returns 0 if not supported."
::= { pmPowerMgmtBanksTableEntry 100 }
pmPowerMgmtBanksTableCurrentHighWarning OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"bank high warning current threshold (A x 10).
Set fails if value is higher than CurrentHighCritical or lower than CurrentLowWarning.
Returns 0 if not supported."
::= { pmPowerMgmtBanksTableEntry 101 }
pmPowerMgmtBanksTableCurrentLowWarning OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"bank low warning current threshold (A x 10).
Set fails if value is higher than CurrentHighWarning or lower than CurrentLowCritical.
Returns 0 if not supported."
::= { pmPowerMgmtBanksTableEntry 102 }
pmPowerMgmtBanksTableCurrentLowCritical OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"bank low critical current threshold (A x 10).
Set fails if value is higher than CurrentLowWarning.
Returns 0 if not supported."
::= { pmPowerMgmtBanksTableEntry 103 }
pmPowerMgmtBanksTableEnergyValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"bank energy value (Wh).
Returns 0 if not supported."
::= { pmPowerMgmtBanksTableEntry 105 }
pmPowerMgmtBanksTableEnergyStartTime OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"time at which energy calculation commenced (ISO8601 format).
Returns N/A if not applicable."
::= { pmPowerMgmtBanksTableEntry 106 }
pmPowerMgmtBanksTableEnergyReset OBJECT-TYPE
SYNTAX INTEGER {
noAction(1),
reset(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"noAction(1) = always returned in a GET. Does nothing if SET.
reset(2) = when SET the reset command is sent to PDU."
::= { pmPowerMgmtBanksTableEntry 107 }
--@ Sensors
pmPowerMgmtTotalNumberOfSensors OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of Sensors managed by the appliance."
::= { pmPowerMgmt 12 }
pmPowerMgmtSensorsTable OBJECT-TYPE
SYNTAX SEQUENCE OF PmPowerMgmtSensorsTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the information about sensors."
::= { pmPowerMgmt 13 }
pmPowerMgmtSensorsTableEntry OBJECT-TYPE
SYNTAX PmPowerMgmtSensorsTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"each entry has the information about the sensors."
INDEX { pmPowerMgmtSensorsTablePortNumber,
pmPowerMgmtSensorsTablePduNumber,
pmPowerMgmtSensorsTableNumber }
::= { pmPowerMgmtSensorsTable 1 }
PmPowerMgmtSensorsTableEntry ::= SEQUENCE {
pmPowerMgmtSensorsTablePortNumber InterfaceIndex, -- serial port #
pmPowerMgmtSensorsTablePduNumber InterfaceIndex,
pmPowerMgmtSensorsTableNumber InterfaceIndex, -- sensor number in PDU
pmPowerMgmtSensorsTableName DisplayString, -- sensor name
pmPowerMgmtSensorsTablePortName DisplayString, -- serial port name
pmPowerMgmtSensorsTablePduId DisplayString, -- PDU ID
pmPowerMgmtSensorsTableType INTEGER, -- sensor type
pmPowerMgmtSensorsTableStatus INTEGER, -- digital sensor status
pmPowerMgmtSensorsTableValue DisplayString, -- actual value for current of the sensor
pmPowerMgmtSensorsTableValueMax DisplayString, -- max value for current
pmPowerMgmtSensorsTableValueMin DisplayString, -- min value for current
pmPowerMgmtSensorsTableValueAvg DisplayString, -- average value for current
pmPowerMgmtSensorsTableValueInt Integer32, -- actual value for current of the sensor
pmPowerMgmtSensorsTableValueMaxInt Integer32, -- max value for current
pmPowerMgmtSensorsTableValueMinInt Integer32, -- min value for current
pmPowerMgmtSensorsTableValueAvgInt Integer32, -- average value for current
pmPowerMgmtSensorsTableValueReset INTEGER, -- reset current stats
pmPowerMgmtSensorsTableHighCritical Integer32, -- set/get sensor high critical threshold
pmPowerMgmtSensorsTableHighWarning Integer32, -- set/get sensor high warning threshold
pmPowerMgmtSensorsTableLowWarning Integer32, -- set/get sensor low warning threshold
pmPowerMgmtSensorsTableLowCritical Integer32, -- set/get sensor low critical threshold
pmPowerMgmtSensorsTableUnit INTEGER, -- set/get sensor unit of measurement
pmPowerMgmtSensorsTableHighCriticalC Integer32, -- get sensor high critical threshold
pmPowerMgmtSensorsTableHighWarningC Integer32, -- get sensor high warning threshold
pmPowerMgmtSensorsTableLowWarningC Integer32, -- get sensor low warning threshold
pmPowerMgmtSensorsTableLowCriticalC Integer32, -- get sensor low critical threshold
pmPowerMgmtSensorsTableHighCriticalF Integer32, -- get sensor high critical threshold
pmPowerMgmtSensorsTableHighWarningF Integer32, -- get sensor high warning threshold
pmPowerMgmtSensorsTableLowWarningF Integer32, -- get sensor low warning threshold
pmPowerMgmtSensorsTableLowCriticalF Integer32 -- get sensor low critical threshold
}
pmPowerMgmtSensorsTablePortNumber OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Serial Port number."
::= { pmPowerMgmtSensorsTableEntry 1 }
pmPowerMgmtSensorsTablePduNumber OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index."
::= { pmPowerMgmtSensorsTableEntry 2 }
pmPowerMgmtSensorsTableNumber OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of the sensor in the PDU."
::= { pmPowerMgmtSensorsTableEntry 3 }
pmPowerMgmtSensorsTableName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Name of the sensor."
::= { pmPowerMgmtSensorsTableEntry 4 }
pmPowerMgmtSensorsTablePortName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Serial Port Name where the PDU is connected."
::= { pmPowerMgmtSensorsTableEntry 5 }
pmPowerMgmtSensorsTablePduId OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PDU identification."
::= { pmPowerMgmtSensorsTableEntry 6 }
pmPowerMgmtSensorsTableType OBJECT-TYPE
SYNTAX INTEGER {
temp-internal (1),
temperature (2),
humidity (3),
air-flow (4),
smoke (5),
dry-concact (6),
water-level (7),
motion (8),
unplugged (9),
unknown (10)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of environmental monitor.
Returns 0 if not supported."
::= { pmPowerMgmtSensorsTableEntry 7 }
pmPowerMgmtSensorsTableStatus OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
triggered(2),
not-applicable(3),
opened(4),
closed(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of digital sensors: Dry-Contact, Water level, Smoke sensor, Motion sensor.
Returns 0 if not supported."
::= { pmPowerMgmtSensorsTableEntry 8 }
--@ Note: Intentionally left space for future expansion
pmPowerMgmtSensorsTableValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Actual value of the sensor.
Returns N/A if not applicable."
::= { pmPowerMgmtSensorsTableEntry 20 }
pmPowerMgmtSensorsTableValueMax OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum value of the sensor.
Returns N/A if not applicable."
::= { pmPowerMgmtSensorsTableEntry 21 }
pmPowerMgmtSensorsTableValueMin OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Minimum value of the sensor.
Returns N/A if not applicable."
::= { pmPowerMgmtSensorsTableEntry 22 }
pmPowerMgmtSensorsTableValueAvg OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average value of the sensor.
Returns N/A if not applicable."
::= { pmPowerMgmtSensorsTableEntry 23 }
pmPowerMgmtSensorsTableValueInt OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Actual value of the sensor.
Returns 0 if not supported."
::= { pmPowerMgmtSensorsTableEntry 25 }
pmPowerMgmtSensorsTableValueMaxInt OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum value of the sensor.
Returns 0 if not supported."
::= { pmPowerMgmtSensorsTableEntry 26 }
pmPowerMgmtSensorsTableValueMinInt OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Minimum value of the sensor.
Returns 0 if not supported."
::= { pmPowerMgmtSensorsTableEntry 27 }
pmPowerMgmtSensorsTableValueAvgInt OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average value of the sensor.
Returns 0 if not supported."
::= { pmPowerMgmtSensorsTableEntry 28 }
pmPowerMgmtSensorsTableValueReset OBJECT-TYPE
SYNTAX INTEGER {
noAction(1),
reset(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"noAction(1) = always returned in a GET. Does nothing if SET.
reset(2) = when SET the reset command is sent to sensor."
::= { pmPowerMgmtSensorsTableEntry 30 }
pmPowerMgmtSensorsTableHighCritical OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"sensor high critical (alarm) threshold (unit x 10) - use unit as returned by pmPowerMgmtSensorsTableUnit.
Set fails if value is lower that CurrentHighWarning.
Returns 0 if not supported."
::= { pmPowerMgmtSensorsTableEntry 40 }
pmPowerMgmtSensorsTableHighWarning OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"sensor high warning threshold (unit x 10) - use unit as returned by pmPowerMgmtSensorsTableUnit.
Set fails if value is higher than HighCritical or lower than LowWarning.
Returns 0 if not supported."
::= { pmPowerMgmtSensorsTableEntry 41 }
pmPowerMgmtSensorsTableLowWarning OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"sensor low warning threshold (unit x 10) - use unit as returned by pmPowerMgmtSensorsTableUnit.
Set fails if value is higher than HighWarning or lower than LowCritical.
Returns 0 if not supported."
::= { pmPowerMgmtSensorsTableEntry 42 }
pmPowerMgmtSensorsTableLowCritical OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"sensor low critical threshold (unit x 10) - use unit as returned by pmPowerMgmtSensorsTableUnit.
Set fails if value is higher than LowWarning.
Returns 0 if not supported."
::= { pmPowerMgmtSensorsTableEntry 43 }
pmPowerMgmtSensorsTableUnit OBJECT-TYPE
SYNTAX INTEGER {
undefined (1),
fahrenheit (2),
celsius (3),
percent (4),
afu (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"sensor unit.
Returns 0 if not supported."
::= { pmPowerMgmtSensorsTableEntry 45 }
pmPowerMgmtSensorsTableHighCriticalC OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"sensor high critical (alarm) threshold (Celcius x 10).
to SET: use pmPowerMgmtSensorsTableHighCritical in proper units (pmPowerMgmtSensorsTableUnit).
Returns 0 if not supported."
::= { pmPowerMgmtSensorsTableEntry 50 }
pmPowerMgmtSensorsTableHighWarningC OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"sensor high warning threshold (Celcius x 10).
to SET: use pmPowerMgmtSensorsTableHighWarning in proper units (pmPowerMgmtSensorsTableUnit).
Returns 0 if not supported."
::= { pmPowerMgmtSensorsTableEntry 51 }
pmPowerMgmtSensorsTableLowWarningC OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"sensor low warning threshold (Celcius x 10).
to SET: use pmPowerMgmtSensorsTableLowWarning in proper units (pmPowerMgmtSensorsTableUnit).
Returns 0 if not supported."
::= { pmPowerMgmtSensorsTableEntry 52 }
pmPowerMgmtSensorsTableLowCriticalC OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"sensor low critical threshold (Celcius x 10).
to SET: use pmPowerMgmtSensorsTableLowCritical in proper units (pmPowerMgmtSensorsTableUnit).
Returns 0 if not supported."
::= { pmPowerMgmtSensorsTableEntry 53 }
pmPowerMgmtSensorsTableHighCriticalF OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"sensor high critical (alarm) threshold (Fahrenheit x 10).
to SET: use pmPowerMgmtSensorsTableHighCritical in proper units (pmPowerMgmtSensorsTableUnit).
Returns 0 if not supported."
::= { pmPowerMgmtSensorsTableEntry 60 }
pmPowerMgmtSensorsTableHighWarningF OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"sensor high warning threshold (Fahrenheit x 10).
to SET: use pmPowerMgmtSensorsTableHighWarning in proper units (pmPowerMgmtSensorsTableUnit).
Returns 0 if not supported."
::= { pmPowerMgmtSensorsTableEntry 61 }
pmPowerMgmtSensorsTableLowWarningF OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"sensor low warning threshold (Fahrenheit x 10).
to SET: use pmPowerMgmtSensorsTableLowWarning in proper units (pmPowerMgmtSensorsTableUnit).
Returns 0 if not supported."
::= { pmPowerMgmtSensorsTableEntry 62 }
pmPowerMgmtSensorsTableLowCriticalF OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"sensor low critical threshold (Fahrenheit x 10).
to SET: use pmPowerMgmtSensorsTableLowCritical in proper units (pmPowerMgmtSensorsTableUnit).
Returns 0 if not supported."
::= { pmPowerMgmtSensorsTableEntry 63 }
END
|