summaryrefslogtreecommitdiff
path: root/MIBS/audiocodes/ALARM-MIB
blob: a6bb830aeb541e5f0cbab3157f06a40b5381b792 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
   ALARM-MIB DEFINITIONS ::= BEGIN

-- look for "acl" to see changes made by ACL group. Changes
-- include:
--
--    o  use Octet String in place of Opaque since postmosy does not
--       support Opaque.
--    o  define ZeroBasedCounter32 to avoid bringing in RMON2, etc.
--

   IMPORTS
--acl
   enterprises,
      MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
      Integer32, Unsigned32, Gauge32,
      TimeTicks, Counter32, Counter64,
      IpAddress, mib-2            FROM SNMPv2-SMI
--acl IpAddress, Opaque, mib-2            FROM SNMPv2-SMI
      DateAndTime,
      RowStatus, RowPointer,
      TEXTUAL-CONVENTION                  FROM SNMPv2-TC
      SnmpAdminString                     FROM SNMP-FRAMEWORK-MIB
      InetAddressType, InetAddress        FROM INET-ADDRESS-MIB
      MODULE-COMPLIANCE, OBJECT-GROUP,
      NOTIFICATION-GROUP                  FROM SNMPv2-CONF;
--acl ZeroBasedCounter32                  FROM RMON2-MIB;

      --acl  This MIB file has been modified by Audiocodes for use
      --acl  in early 4.4 development. The standard MIB will be used
      --acl  once the official MIB OID assignment is announced.

     alarmMIB MODULE-IDENTITY
      LAST-UPDATED "200409090000Z"  -- September 09, 2004
         ORGANIZATION "IETF Distributed Management Working Group"
         CONTACT-INFO
              "WG EMail: disman@ietf.org
              Subscribe: disman-request@ietf.org
              http://www.ietf.org/html.charters/disman-charter.html

              Chair:     Randy Presuhn



                         randy_presuhn@mindspring.com

              Editors:   Sharon Chisholm
                         Nortel Networks
                         PO Box 3511 Station C
                         Ottawa, Ont.  K1Y 4H7
                         Canada
                         schishol@nortelnetworks.com

                         Dan Romascanu
                         Avaya
                         Atidim Technology Park, Bldg. #3
                         Tel Aviv, 61131
                         Israel
                         Tel: +972-3-645-8414
                         Email: dromasca@avaya.com"
      DESCRIPTION
           "The MIB module describes a generic solution
           to model alarms and to store the current list
           of active alarms.

           Copyright (C) The Internet Society (2004).  The
           initial version of this MIB module was published
           in RFC 3877.  For full legal notices see the RFC
           itself.  Supplementary information may be available on:
           http://www.ietf.org/copyrights/ianamib.html"
      REVISION    "200409090000Z"  -- September 09, 2004
      DESCRIPTION
          "Initial version, published as RFC 3877."
      ::= { mib-2 118 }

   alarmObjects OBJECT IDENTIFIER ::= { alarmMIB 1 }

   alarmNotifications OBJECT IDENTIFIER ::= { alarmMIB 0 }

   alarmModel OBJECT IDENTIFIER ::= { alarmObjects 1 }

   alarmActive  OBJECT IDENTIFIER ::= { alarmObjects 2 }

   alarmClear OBJECT IDENTIFIER ::= { alarmObjects 3 }

   -- Textual Conventions

   --acl  Added this to avoid bringing in RMON, which requires RMON2, etc.
   --acl  This also avoids a duplicate name (ChannelStatus) with same OID.
   ZeroBasedCounter32 ::= TEXTUAL-CONVENTION
       STATUS current
       DESCRIPTION
          ""
       SYNTAX Gauge32

    -- ResourceId is intended to be a general textual convention
    -- that can be used outside of the set of MIBs related to
    -- Alarm Management.

   ResourceId ::= TEXTUAL-CONVENTION
       STATUS current



       DESCRIPTION
            "A unique identifier for this resource.

            The type of the resource can be determined by looking
            at the OID that describes the resource.

            Resources must be identified in a consistent manner.
            For example, if this resource is an interface, this
            object MUST point to an ifIndex and if this resource
            is a physical entity [RFC2737], then this MUST point
            to an entPhysicalDescr, given that entPhysicalIndex
            is not accessible.  In general, the value is the
            name of the instance of the first accessible columnar
            object in the conceptual row of a table that is
            meaningful for this resource type, which SHOULD
            be defined in an IETF standard MIB."
       SYNTAX         OBJECT IDENTIFIER

    -- LocalSnmpEngineOrZeroLenStr is intended to be a general
    -- textual convention that can be used outside of the set of
    -- MIBs related to Alarm Management.

     LocalSnmpEngineOrZeroLenStr ::= TEXTUAL-CONVENTION
         STATUS current
         DESCRIPTION
             "An SNMP Engine ID or a zero-length string. The
              instantiation of this textual convention will provide
              guidance on when this will be an SNMP Engine ID and
              when it will be a zero lengths string"
         SYNTAX         OCTET STRING (SIZE(0 | 5..32))


   -- Alarm Model

   alarmModelLastChanged  OBJECT-TYPE
         SYNTAX      TimeTicks
         MAX-ACCESS  read-only
         STATUS      current
         DESCRIPTION
            "The value of sysUpTime at the time of the last
            creation, deletion or modification of an entry in
            the alarmModelTable.

            If the number and content of entries has been unchanged
            since the last re-initialization of the local network
            management subsystem, then the value of this object
            MUST be zero."
         ::= { alarmModel 1 }

   alarmModelTable OBJECT-TYPE
      SYNTAX      SEQUENCE OF AlarmModelEntry
      MAX-ACCESS  not-accessible



      STATUS      current
      DESCRIPTION
          "A table of information about possible alarms on the system,
           and how they have been modelled."
      ::= { alarmModel 2 }

   alarmModelEntry OBJECT-TYPE
      SYNTAX      AlarmModelEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "Entries appear in this table for each possible alarm state.
          This table MUST be persistent across system reboots."
      INDEX       { alarmListName, alarmModelIndex, alarmModelState }
      ::= { alarmModelTable 1 }

   AlarmModelEntry ::= SEQUENCE {
      alarmModelIndex                 Unsigned32,
      alarmModelState                 Unsigned32,
      alarmModelNotificationId        OBJECT IDENTIFIER,
      alarmModelVarbindIndex          Unsigned32,
      alarmModelVarbindValue          Integer32,
      alarmModelDescription           SnmpAdminString,
      alarmModelSpecificPointer       RowPointer,
      alarmModelVarbindSubtree        OBJECT IDENTIFIER,
      alarmModelResourcePrefix        OBJECT IDENTIFIER,
      alarmModelRowStatus             RowStatus
      }


   alarmModelIndex OBJECT-TYPE
      SYNTAX     Unsigned32 (1..4294967295)
      MAX-ACCESS not-accessible
      STATUS     current
      DESCRIPTION
          "An integer that acts as an alarm Id
          to uniquely identify each alarm
          within the named alarm list. "
      ::= { alarmModelEntry 1 }

   alarmModelState OBJECT-TYPE
      SYNTAX  Unsigned32 (1..4294967295)
      MAX-ACCESS not-accessible
      STATUS       current
      DESCRIPTION
           "A value of 1 MUST indicate a clear alarm state.
           The value of this object MUST be less than the
           alarmModelState of more severe alarm states for
           this alarm.  The value of this object MUST be more
           than the alarmModelState of less severe alarm states
           for this alarm."
       ::= { alarmModelEntry 2 }




   alarmModelNotificationId OBJECT-TYPE
      SYNTAX      OBJECT IDENTIFIER
      MAX-ACCESS  read-create
      STATUS      current
      DESCRIPTION
          "The NOTIFICATION-TYPE object identifier of this alarm
          state transition. If there is no notification associated
          with this alarm state, the value of this object MUST be
          '0.0'"
      DEFVAL { { 0 0 } }
      ::= { alarmModelEntry 3 }

   alarmModelVarbindIndex  OBJECT-TYPE
      SYNTAX  Unsigned32
      MAX-ACCESS   read-create
      STATUS       current
      DESCRIPTION
        "The index into the varbind listing of the notification
        indicated by alarmModelNotificationId which helps
        signal that the given alarm has changed state.
        If there is no applicable varbind, the value of this
        object MUST be zero.

        Note that the value of alarmModelVarbindIndex acknowledges
        the existence of the first two obligatory varbinds in
        the InformRequest-PDU and SNMPv2-Trap-PDU (sysUpTime.0
        and snmpTrapOID.0).  That is, a value of 2 refers to
        the snmpTrapOID.0.

        If the incoming notification is instead an SNMPv1 Trap-PDU,
        then an appropriate value for sysUpTime.0 or snmpTrapOID.0
        shall be determined by using the rules in section 3.1 of
        [RFC3584]"
        DEFVAL { 0 }
       ::= { alarmModelEntry 4 }

   alarmModelVarbindValue OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS   read-create
      STATUS       current
   DESCRIPTION
     "The value that the varbind indicated by
     alarmModelVarbindIndex takes to indicate
     that the alarm has entered this state.

     If alarmModelVarbindIndex has a value of 0, so
     MUST alarmModelVarbindValue.
        "
     DEFVAL { 0 }
    ::= { alarmModelEntry 5 }

alarmModelDescription OBJECT-TYPE
    SYNTAX SnmpAdminString
    MAX-ACCESS read-create
    STATUS current
    DESCRIPTION
      "A brief description of this alarm and state suitable
      to display to operators."
   DEFVAL { "" }
   ::= { alarmModelEntry 6 }

alarmModelSpecificPointer OBJECT-TYPE
   SYNTAX     RowPointer
   MAX-ACCESS read-create
   STATUS     current
   DESCRIPTION
     "If no additional, model-specific Alarm MIB is supported by
      the system the value of this object is `0.0'and attempts
      to set it to any other value MUST be rejected appropriately.

      When a model-specific Alarm MIB is supported, this object
      MUST refer to the first accessible object in a corresponding
      row of the model definition in one of these model-specific
      MIB and attempts to set this object to { 0 0 } or any other
      value MUST be rejected appropriately."
      DEFVAL { { 0 0 } }
      ::= { alarmModelEntry 7 }

     alarmModelVarbindSubtree  OBJECT-TYPE
        SYNTAX  OBJECT IDENTIFIER
        MAX-ACCESS   read-create
        STATUS       current
        DESCRIPTION
          "The name portion of each VarBind in the notification,
           in order, is compared to the value of this object.
           If the name is equal to or a subtree of the value
           of this object, for purposes of computing the value
           of AlarmActiveResourceID the 'prefix' will be the
           matching portion, and the 'indexes' will be any
           remainder.  The examination of varbinds ends with
           the first match. If the value of this object is 0.0,
           then the first varbind, or in the case of v2, the
           first varbind after the timestamp and the trap
           OID, will always be matched.
          "
         DEFVAL { { 0 0 } }
        ::= { alarmModelEntry 8 }

     alarmModelResourcePrefix  OBJECT-TYPE
        SYNTAX  OBJECT IDENTIFIER
        MAX-ACCESS   read-create
        STATUS       current
        DESCRIPTION



          "The value of AlarmActiveResourceID is computed
           by appending any indexes extracted in accordance
           with the description of alarmModelVarbindSubtree
           onto the value of this object.  If this object's
           value is 0.0, then the 'prefix' extracted is used
           instead.
          "
        DEFVAL { { 0 0 } }
        ::= { alarmModelEntry 9 }


   alarmModelRowStatus OBJECT-TYPE
      SYNTAX     RowStatus
      MAX-ACCESS read-create
      STATUS     current
      DESCRIPTION
       "Control for creating and deleting entries.  Entries may be
       modified while active. Alarms whose alarmModelRowStatus is
       not active will not appear in either the alarmActiveTable
       or the alarmClearTable. Setting this object to notInService
       cannot be used as an alarm suppression mechanism. Entries
       that are notInService will disappear as described in RFC2579.

       This row can not be modified while it is being
       referenced by a value of alarmActiveModelPointer. In these
       cases, an error of `inconsistentValue' will be returned to
       the manager.

       This entry may be deleted while it is being
       referenced by a value of alarmActiveModelPointer. This results
       in the deletion of this entry and entries in the active alarms
       referencing this entry via an alarmActiveModelPointer.

       As all read-create objects in this table have a DEFVAL clause,
       there is no requirement that any object be explicitly set
       before this row can become active. Note that a row consisting
       only of default values is not very meaningful."
      ::= { alarmModelEntry 10 }



   -- Active Alarm Table --

   alarmActiveLastChanged  OBJECT-TYPE
      SYNTAX      TimeTicks
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "The value of sysUpTime at the time of the last
          creation or deletion of an entry in the alarmActiveTable.
          If the number of entries has been unchanged since the
          last re-initialization of the local network management



          subsystem, then this object contains a zero value."
      ::= { alarmActive 1 }

    alarmActiveOverflow  OBJECT-TYPE
        SYNTAX      Counter32
        UNITS       "active alarms"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
           "The number of active alarms that have not been put into
            the alarmActiveTable since system restart as a result
            of extreme resource constraints."
        ::= { alarmActive 5 }

   alarmActiveTable OBJECT-TYPE
      SYNTAX      SEQUENCE OF AlarmActiveEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "A table of Active Alarms entries."
      ::= { alarmActive 2 }

   alarmActiveEntry OBJECT-TYPE
      SYNTAX      AlarmActiveEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "Entries appear in this table when alarms are raised.  They
           are removed when the alarm is cleared.

           If under extreme resource constraint the system is unable to
           add any more entries into this table, then the
           alarmActiveOverflow statistic will be increased by one."
      INDEX       { alarmListName, alarmActiveDateAndTime,
                    alarmActiveIndex }
      ::= { alarmActiveTable 1 }

   AlarmActiveEntry ::= SEQUENCE {
      alarmListName                    SnmpAdminString,
      alarmActiveDateAndTime           DateAndTime,
      alarmActiveIndex                 Unsigned32,
      alarmActiveEngineID              LocalSnmpEngineOrZeroLenStr,
      alarmActiveEngineAddressType     InetAddressType,
      alarmActiveEngineAddress         InetAddress,
      alarmActiveContextName           SnmpAdminString,
      alarmActiveVariables             Unsigned32,
      alarmActiveNotificationID        OBJECT IDENTIFIER,
      alarmActiveResourceId            ResourceId,
      alarmActiveDescription           SnmpAdminString,
      alarmActiveLogPointer            RowPointer,
      alarmActiveModelPointer          RowPointer,
      alarmActiveSpecificPointer       RowPointer }




   alarmListName OBJECT-TYPE
      SYNTAX     SnmpAdminString (SIZE(0..32))
      MAX-ACCESS not-accessible
      STATUS     current
      DESCRIPTION
       "The name of the list of alarms.  This SHOULD be the same as
       nlmLogName if the Notification Log MIB [RFC3014] is supported.
       This SHOULD be the same as, or contain as a prefix, the
       applicable snmpNotifyFilterProfileName if the
       SNMP-NOTIFICATION-MIB DEFINITIONS [RFC3413] is supported.

       An implementation may allow multiple named alarm lists, up to
       some implementation-specific limit (which may be none).  A
       zero-length list name is reserved for creation and deletion
       by the managed system, and MUST be used as the default log
       name by systems that do not support named alarm lists."
      ::= { alarmActiveEntry 1 }

   alarmActiveDateAndTime OBJECT-TYPE
      SYNTAX      DateAndTime
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "The local date and time when the error occurred.

          This object facilitates retrieving all instances of
          alarms that have been raised or have changed state
          since a given point in time.

          Implementations MUST include the offset from UTC,
          if available.  Implementation in environments in which
          the UTC offset is not available is NOT RECOMMENDED."
      ::= { alarmActiveEntry 2 }


   alarmActiveIndex OBJECT-TYPE
      SYNTAX     Unsigned32 (1..4294967295)
      MAX-ACCESS not-accessible
      STATUS     current
      DESCRIPTION
          "A strictly monotonically increasing integer which
          acts as the index of entries within the named alarm
          list.  It wraps back to 1 after it reaches its
          maximum value."
      ::= { alarmActiveEntry 3 }

   alarmActiveEngineID OBJECT-TYPE
      SYNTAX      LocalSnmpEngineOrZeroLenStr
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION



          "The identification of the SNMP engine at which the alarm
           originated. If the alarm is from an SNMPv1 system this
           object is a zero length string."
      ::= { alarmActiveEntry 4 }

   alarmActiveEngineAddressType OBJECT-TYPE
      SYNTAX      InetAddressType
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
       "This object indicates what type of address is stored in
       the alarmActiveEngineAddress object - IPv4, IPv6, DNS, etc."
      ::= { alarmActiveEntry 5 }

   alarmActiveEngineAddress OBJECT-TYPE
      SYNTAX      InetAddress
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
       "The address of the SNMP engine on which the alarm is
       occurring.

       This object MUST always be instantiated, even if the list
       can contain alarms from only one engine."
      ::= { alarmActiveEntry 6 }

   alarmActiveContextName OBJECT-TYPE
      SYNTAX      SnmpAdminString (SIZE(0..32))
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The name of the SNMP MIB context from which the alarm came.
           For SNMPv1 alarms this is the community string from the Trap.
           Note that care MUST be taken when selecting community
           strings to ensure that these can be represented as a
           well-formed SnmpAdminString. Community or Context names
           that are not well-formed SnmpAdminStrings will be mapped
           to zero length strings.

           If the alarm's source SNMP engine is known not to support
           multiple contexts, this object is a zero length string."
      ::= { alarmActiveEntry 7 }

   alarmActiveVariables OBJECT-TYPE
      SYNTAX      Unsigned32
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The number of variables in alarmActiveVariableTable for this
          alarm."
      ::= { alarmActiveEntry 8 }





   alarmActiveNotificationID OBJECT-TYPE
      SYNTAX      OBJECT IDENTIFIER
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The NOTIFICATION-TYPE object identifier of the alarm
          state transition that is occurring."
      ::= { alarmActiveEntry 9 }

   alarmActiveResourceId    OBJECT-TYPE
      SYNTAX      ResourceId
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "This object identifies the resource under alarm.

         If there is no corresponding resource, then
         the value of this object MUST be 0.0."
      ::= { alarmActiveEntry 10 }

   alarmActiveDescription    OBJECT-TYPE
      SYNTAX      SnmpAdminString
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "This object provides a textual description of the
         active alarm.  This text is generated dynamically by the
         notification generator to provide useful information
         to the human operator.  This information SHOULD
         provide information allowing the operator to locate
         the resource for which this alarm is being generated.
         This information is not intended for consumption by
         automated tools."
      ::= { alarmActiveEntry 11 }


   alarmActiveLogPointer OBJECT-TYPE
      SYNTAX     RowPointer
      MAX-ACCESS read-only
      STATUS     current
      DESCRIPTION
          "A pointer to the corresponding row in a
          notification logging MIB where the state change
          notification for this active alarm is logged.
          If no log entry applies to this active alarm,
          then this object MUST have the value of 0.0"
      ::= { alarmActiveEntry 12 }

   alarmActiveModelPointer OBJECT-TYPE
      SYNTAX     RowPointer
      MAX-ACCESS read-only



      STATUS     current
      DESCRIPTION
          "A pointer to the corresponding row in the
          alarmModelTable for this active alarm. This
          points not only to the alarm model being
          instantiated, but also to the specific alarm
          state that is active."
      ::= { alarmActiveEntry 13 }

   alarmActiveSpecificPointer OBJECT-TYPE
      SYNTAX     RowPointer
      MAX-ACCESS read-only
      STATUS     current
      DESCRIPTION
     "If no additional, model-specific, Alarm MIB is supported by
     the system this object is `0.0'.  When a model-specific Alarm
     MIB is supported, this object is the instance pointer to the
     specific model-specific active alarm list."
      ::= { alarmActiveEntry 14 }


   -- Active Alarm Variable Table --

   alarmActiveVariableTable OBJECT-TYPE
      SYNTAX      SEQUENCE OF AlarmActiveVariableEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "A table of variables to go with active alarm entries."
      ::= { alarmActive 3 }

   alarmActiveVariableEntry OBJECT-TYPE
      SYNTAX      AlarmActiveVariableEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "Entries appear in this table when there are variables in
          the varbind list of a corresponding alarm in
          alarmActiveTable.

          Entries appear in this table as though
          the trap/notification had been transported using a
          SNMPv2-Trap-PDU, as defined in [RFC3416] - i.e, the
          alarmActiveVariableIndex 1 will always be sysUpTime
          and alarmActiveVariableIndex 2 will always be
          snmpTrapOID.

          If the incoming notification is instead an SNMPv1 Trap-PDU and
          the value of alarmModelVarbindIndex is 1 or 2, an appropriate
          value for sysUpTime.0 or snmpTrapOID.0 shall be determined
          by using the rules in section 3.1 of [RFC3584]."
      INDEX   {  alarmListName, alarmActiveIndex,



                 alarmActiveVariableIndex }
      ::= { alarmActiveVariableTable 1 }

   AlarmActiveVariableEntry ::= SEQUENCE {
      alarmActiveVariableIndex                 Unsigned32,
      alarmActiveVariableID                    OBJECT IDENTIFIER,
      alarmActiveVariableValueType             INTEGER,
      alarmActiveVariableCounter32Val          Counter32,
      alarmActiveVariableUnsigned32Val         Unsigned32,
      alarmActiveVariableTimeTicksVal          TimeTicks,
      alarmActiveVariableInteger32Val          Integer32,
      alarmActiveVariableOctetStringVal        OCTET STRING,
      alarmActiveVariableIpAddressVal          IpAddress,
      alarmActiveVariableOidVal                OBJECT IDENTIFIER,
      alarmActiveVariableCounter64Val          Counter64,
      alarmActiveVariableOpaqueVal             OCTET STRING }
--acl alarmActiveVariableOpaqueVal             Opaque }

   alarmActiveVariableIndex OBJECT-TYPE
      SYNTAX     Unsigned32 (1..4294967295)
      MAX-ACCESS not-accessible
      STATUS     current
      DESCRIPTION
          "A strictly monotonically increasing integer, starting at
          1 for a given alarmActiveIndex, for indexing variables
          within the active alarm variable list. "
      ::= { alarmActiveVariableEntry 1 }

   alarmActiveVariableID OBJECT-TYPE
      SYNTAX     OBJECT IDENTIFIER
      MAX-ACCESS read-only
      STATUS     current
      DESCRIPTION
          "The alarm variable's object identifier."
      ::= { alarmActiveVariableEntry 2 }

   alarmActiveVariableValueType OBJECT-TYPE
      SYNTAX      INTEGER {
            counter32(1),
            unsigned32(2),
            timeTicks(3),
            integer32(4),
            ipAddress(5),
            octetString(6),
            objectId(7),
            counter64(8),
            opaque(9)
            }
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The type of the value.  One and only one of the value
          objects that follow is used for a given row in this table,



          based on this type."
      ::= { alarmActiveVariableEntry 3 }

   alarmActiveVariableCounter32Val OBJECT-TYPE
      SYNTAX      Counter32
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The value when alarmActiveVariableType is 'counter32'."
      ::= { alarmActiveVariableEntry 4 }

   alarmActiveVariableUnsigned32Val OBJECT-TYPE
      SYNTAX      Unsigned32
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The value when alarmActiveVariableType is 'unsigned32'."
      ::= { alarmActiveVariableEntry 5 }

   alarmActiveVariableTimeTicksVal OBJECT-TYPE
      SYNTAX      TimeTicks
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The value when alarmActiveVariableType is 'timeTicks'."
      ::= { alarmActiveVariableEntry 6 }

   alarmActiveVariableInteger32Val OBJECT-TYPE
      SYNTAX      Integer32
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The value when alarmActiveVariableType is 'integer32'."
      ::= { alarmActiveVariableEntry 7 }

   alarmActiveVariableOctetStringVal OBJECT-TYPE
      SYNTAX      OCTET STRING (SIZE(0..65535))
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The value when alarmActiveVariableType is 'octetString'."
      ::= { alarmActiveVariableEntry 8 }

   alarmActiveVariableIpAddressVal OBJECT-TYPE
      SYNTAX      IpAddress
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The value when alarmActiveVariableType is 'ipAddress'."
      ::= { alarmActiveVariableEntry 9 }

   alarmActiveVariableOidVal OBJECT-TYPE



      SYNTAX      OBJECT IDENTIFIER
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The value when alarmActiveVariableType is 'objectId'."
      ::= { alarmActiveVariableEntry 10 }

   alarmActiveVariableCounter64Val OBJECT-TYPE
      SYNTAX      Counter64
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The value when alarmActiveVariableType is 'counter64'."
      ::= { alarmActiveVariableEntry 11 }

   alarmActiveVariableOpaqueVal OBJECT-TYPE
--acl SYNTAX      Opaque (SIZE(0..65535))
      SYNTAX      OCTET STRING
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The value when alarmActiveVariableType is 'opaque'.

          Note that although RFC2578 [RFC2578] forbids the use
          of Opaque in 'standard' MIB modules, this particular
          usage is driven by the need to be able to accurately
          represent any well-formed notification, and justified
          by the need for backward compatibility."
      ::= { alarmActiveVariableEntry 12 }

   -- Statistics --

   alarmActiveStatsTable  OBJECT-TYPE
         SYNTAX  SEQUENCE OF AlarmActiveStatsEntry
         MAX-ACCESS  not-accessible
         STATUS  current
         DESCRIPTION
            "This table represents the alarm statistics
            information."
     ::= { alarmActive 4 }


   alarmActiveStatsEntry OBJECT-TYPE
         SYNTAX  AlarmActiveStatsEntry
         MAX-ACCESS  not-accessible
         STATUS  current
         DESCRIPTION
            "Statistics on the current active alarms."
         INDEX   { alarmListName }

     ::= {  alarmActiveStatsTable 1 }






   AlarmActiveStatsEntry ::=
         SEQUENCE {
              alarmActiveStatsActiveCurrent  Gauge32,
              alarmActiveStatsActives        ZeroBasedCounter32,
              alarmActiveStatsLastRaise      TimeTicks,
              alarmActiveStatsLastClear      TimeTicks
                   }


   alarmActiveStatsActiveCurrent OBJECT-TYPE
         SYNTAX Gauge32
         MAX-ACCESS read-only
         STATUS  current
         DESCRIPTION
            "The total number of currently active alarms on the system."

          ::= { alarmActiveStatsEntry 1 }

   alarmActiveStatsActives OBJECT-TYPE
         SYNTAX ZeroBasedCounter32
         MAX-ACCESS read-only
         STATUS  current
         DESCRIPTION
            "The total number of active alarms since system restarted."

          ::= { alarmActiveStatsEntry 2 }

   alarmActiveStatsLastRaise  OBJECT-TYPE
      SYNTAX      TimeTicks
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "The value of sysUpTime at the time of the last
          alarm raise for this alarm list.
          If no alarm raises have occurred since the
          last re-initialization of the local network management
          subsystem, then this object contains a zero value."
    ::= { alarmActiveStatsEntry 3 }

   alarmActiveStatsLastClear  OBJECT-TYPE
      SYNTAX      TimeTicks
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "The value of sysUpTime at the time of the last
          alarm clear for this alarm list.
          If no alarm clears have occurred since the
          last re-initialization of the local network management
          subsystem, then this object contains a zero value."
    ::= { alarmActiveStatsEntry 4 }




   -- Alarm Clear

   alarmClearMaximum OBJECT-TYPE
    SYNTAX Unsigned32
    MAX-ACCESS read-write
    STATUS current
    DESCRIPTION
      "This object specifies the maximum number of cleared
      alarms to store in the alarmClearTable. When this
      number is reached, the cleared alarms with the
      earliest clear time will be removed from the table."
    ::= { alarmClear 1 }

   alarmClearTable  OBJECT-TYPE
         SYNTAX  SEQUENCE OF AlarmClearEntry
         MAX-ACCESS  not-accessible
         STATUS  current
         DESCRIPTION
            "This table contains information on
            cleared alarms."
     ::= { alarmClear 2 }


   alarmClearEntry OBJECT-TYPE
         SYNTAX  AlarmClearEntry
         MAX-ACCESS  not-accessible
         STATUS  current
         DESCRIPTION
            "Information on a cleared alarm."
         INDEX   { alarmListName, alarmClearDateAndTime,
   alarmClearIndex }

     ::= {  alarmClearTable 1 }



   AlarmClearEntry ::=
         SEQUENCE {
      alarmClearIndex                 Unsigned32,
      alarmClearDateAndTime           DateAndTime,
      alarmClearEngineID              LocalSnmpEngineOrZeroLenStr,
      alarmClearEngineAddressType     InetAddressType,
      alarmClearEngineAddress         InetAddress,
      alarmClearContextName           SnmpAdminString,
      alarmClearNotificationID        OBJECT IDENTIFIER,
      alarmClearResourceId            ResourceId,
      alarmClearLogIndex              Unsigned32,
      alarmClearModelPointer          RowPointer
      }

   alarmClearIndex OBJECT-TYPE
      SYNTAX     Unsigned32 (1..4294967295)



      MAX-ACCESS not-accessible
      STATUS     current
      DESCRIPTION
          "An integer which acts as the index of entries within
          the named alarm list.  It wraps back to 1 after it
          reaches its maximum value.

          This object has the same value as the alarmActiveIndex that
          this alarm instance had when it was active."
      ::= { alarmClearEntry 1 }

   alarmClearDateAndTime OBJECT-TYPE
      SYNTAX      DateAndTime
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "The local date and time when the alarm cleared.

          This object facilitates retrieving all instances of
          alarms that have been cleared since a given point in time.

          Implementations MUST include the offset from UTC,
          if available.  Implementation in environments in which
          the UTC offset is not available is NOT RECOMMENDED."
      ::= { alarmClearEntry 2 }

   alarmClearEngineID OBJECT-TYPE
      SYNTAX      LocalSnmpEngineOrZeroLenStr
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The identification of the SNMP engine at which the alarm
           originated. If the alarm is from an SNMPv1 system this
           object is a zero length string."
      ::= { alarmClearEntry 3 }

   alarmClearEngineAddressType OBJECT-TYPE
      SYNTAX      InetAddressType
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
       "This object indicates what type of address is stored in
       the alarmActiveEngineAddress object - IPv4, IPv6, DNS, etc."
      ::= { alarmClearEntry 4 }

   alarmClearEngineAddress OBJECT-TYPE
      SYNTAX      InetAddress
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
       "The Address of the SNMP engine on which the alarm was
       occurring. This is used to identify the source of an SNMPv1



       trap, since an alarmActiveEngineId cannot be extracted from the
       SNMPv1 trap PDU.

       This object MUST always be instantiated, even if the list
       can contain alarms from only one engine."
      ::= { alarmClearEntry 5 }

   alarmClearContextName OBJECT-TYPE
      SYNTAX      SnmpAdminString (SIZE(0..32))
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The name of the SNMP MIB context from which the alarm came.
          For SNMPv1 traps this is the community string from the Trap.
          Note that care needs to be taken when selecting community
          strings to ensure that these can be represented as a
          well-formed SnmpAdminString. Community or Context names
          that are not well-formed SnmpAdminStrings will be mapped
          to zero length strings.

          If the alarm's source SNMP engine is known not to support
          multiple contexts, this object is a zero length string."
      ::= { alarmClearEntry 6 }

   alarmClearNotificationID OBJECT-TYPE
      SYNTAX      OBJECT IDENTIFIER
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The NOTIFICATION-TYPE object identifier of the alarm
          clear."
      ::= { alarmClearEntry 7 }

   alarmClearResourceId    OBJECT-TYPE
      SYNTAX      ResourceId
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "This object identifies the resource that was under alarm.

         If there is no corresponding resource, then
         the value of this object MUST be 0.0."
      ::= { alarmClearEntry 8 }

   alarmClearLogIndex OBJECT-TYPE
      SYNTAX     Unsigned32 (0..4294967295)
      MAX-ACCESS read-only
      STATUS     current
      DESCRIPTION
          "This number MUST be the same as the log index of the
          applicable row in the notification log MIB, if it exists.
          If no log index applies to the trap, then this object



          MUST have the value of 0."
      ::= { alarmClearEntry 9 }

   alarmClearModelPointer OBJECT-TYPE
      SYNTAX     RowPointer
      MAX-ACCESS read-only
      STATUS     current
      DESCRIPTION
          "A pointer to the corresponding row in the
          alarmModelTable for this cleared alarm."
      ::= { alarmClearEntry 10 }


   -- Notifications

   alarmActiveState NOTIFICATION-TYPE
    OBJECTS     { alarmActiveModelPointer,
                  alarmActiveResourceId }
    STATUS      current
    DESCRIPTION
       "An instance of the alarm indicated by
       alarmActiveModelPointer has been raised
       against the entity indicated by
       alarmActiveResourceId.

       The agent must throttle the generation of
       consecutive alarmActiveState traps so that there is at
       least a two-second gap between traps of this
       type against the same alarmActiveModelPointer and
       alarmActiveResourceId.  When traps are throttled,
       they are dropped, not queued for sending at a future time.

       A management application should periodically check
       the value of alarmActiveLastChanged to detect any
       missed alarmActiveState notification-events, e.g.,
       due to throttling or transmission loss."
    ::= { alarmNotifications 2 }

   alarmClearState NOTIFICATION-TYPE
      OBJECTS     { alarmActiveModelPointer,
                    alarmActiveResourceId }
      STATUS      current
      DESCRIPTION
        "An instance of the alarm indicated by
        alarmActiveModelPointer has been cleared against
        the entity indicated by alarmActiveResourceId.

        The agent must throttle the generation of
       consecutive alarmActiveClear traps so that there is at
       least a two-second gap between traps of this
       type against the same alarmActiveModelPointer and
       alarmActiveResourceId.  When traps are throttled,



       they are dropped, not queued for sending at a future time.

       A management application should periodically check
       the value of alarmActiveLastChanged to detect any
       missed alarmClearState notification-events, e.g.,
       due to throttling or transmission loss."
      ::= { alarmNotifications 3 }

   -- Conformance

   alarmConformance OBJECT IDENTIFIER ::= { alarmMIB 2 }

   alarmCompliances OBJECT IDENTIFIER ::= { alarmConformance 1 }

   alarmCompliance MODULE-COMPLIANCE
         STATUS  current
         DESCRIPTION
             "The compliance statement for systems supporting
             the Alarm MIB."
         MODULE -- this module
             MANDATORY-GROUPS {
              alarmActiveGroup,
              alarmModelGroup
             }
         GROUP       alarmActiveStatsGroup
          DESCRIPTION
              "This group is optional."
         GROUP       alarmClearGroup
          DESCRIPTION
              "This group is optional."
         GROUP       alarmNotificationsGroup
          DESCRIPTION
              "This group is optional."
      ::= { alarmCompliances 1 }

   alarmGroups OBJECT IDENTIFIER ::= { alarmConformance 2 }

   alarmModelGroup OBJECT-GROUP
      OBJECTS {
          alarmModelLastChanged,
          alarmModelNotificationId,
          alarmModelVarbindIndex,
          alarmModelVarbindValue,
          alarmModelDescription,
          alarmModelSpecificPointer,
          alarmModelVarbindSubtree,
          alarmModelResourcePrefix,
          alarmModelRowStatus
         }
       STATUS   current
       DESCRIPTION
                  "Alarm model group."



       ::= { alarmGroups 1}


   alarmActiveGroup OBJECT-GROUP
           OBJECTS {
              alarmActiveLastChanged,
              alarmActiveOverflow,
              alarmActiveEngineID,
              alarmActiveEngineAddressType,
              alarmActiveEngineAddress,
              alarmActiveContextName,
              alarmActiveVariables,
              alarmActiveNotificationID,
              alarmActiveResourceId,
              alarmActiveDescription,
              alarmActiveLogPointer,
              alarmActiveModelPointer,
              alarmActiveSpecificPointer,
              alarmActiveVariableID,
              alarmActiveVariableValueType,
              alarmActiveVariableCounter32Val,
              alarmActiveVariableUnsigned32Val,
              alarmActiveVariableTimeTicksVal,
              alarmActiveVariableInteger32Val,
              alarmActiveVariableOctetStringVal,
              alarmActiveVariableIpAddressVal,
              alarmActiveVariableOidVal,
              alarmActiveVariableCounter64Val,
              alarmActiveVariableOpaqueVal
             }
             STATUS   current
             DESCRIPTION
                  "Active Alarm list group."
             ::= { alarmGroups 2}

       alarmActiveStatsGroup  OBJECT-GROUP
             OBJECTS  {
                      alarmActiveStatsActives,
                      alarmActiveStatsActiveCurrent,
                      alarmActiveStatsLastRaise,
                      alarmActiveStatsLastClear
                       }
             STATUS   current
             DESCRIPTION
                  "Active alarm summary group."
             ::= { alarmGroups 3}


   alarmClearGroup  OBJECT-GROUP
             OBJECTS  {
      alarmClearMaximum,
      alarmClearEngineID,



      alarmClearEngineAddressType,
      alarmClearEngineAddress,
      alarmClearContextName,
      alarmClearNotificationID,
      alarmClearResourceId,
      alarmClearLogIndex,
      alarmClearModelPointer
                       }
             STATUS   current
             DESCRIPTION
                  "Cleared alarm group."
             ::= { alarmGroups 4}

   alarmNotificationsGroup NOTIFICATION-GROUP
      NOTIFICATIONS { alarmActiveState, alarmClearState }
      STATUS        current
      DESCRIPTION
              "The collection of notifications that can be used to
              model alarms for faults lacking pre-existing
              notification definitions."
      ::= { alarmGroups 6 }

   END