1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
1438
1439
1440
1441
1442
1443
1444
1445
1446
1447
1448
1449
1450
|
-- ATS MIB
-- MIB for Uninterruptible Power Supplies
--
-- { iso org(3) dod(6) internet(1) private(4) enterprises(1) ats(37662)
-- product(1) webAppliance(2) atsAgent(2)
-- ==============================================================================================
---
--- Revision History
---
--- v0.80 14-Jan-2013 Kevin Lee
--- Created
---
--- v0.81 24-Jan-2013 Kevin Lee
--- 1. Modified the atsConfigGroupAutoReturnPhaseDegree select item.
--- 2. Modified the trapsReceiverAddr type.
---
--- v0.82 26-Feb-2013 Kevin Lee
--- 1. Added the over load 200% item.
--- 2. Added the "ReStart Error 4 Times" alarm item.
--- 3. Removed the "Internal Switching Disabled" alarm item.
---
--- v0.83 07-March-2013 Kevin Lee
--- 1. Removed the atsOutputGroupOutputStatus item.
---
--- v0.84 08-March-2013 Kevin Lee
--- 1. Modified the over load 200% item.
---
--- v0.85 08-April-2013 Kevin Lee
--- 1. Removed same item.
---
--- v0.86 15-April-2013 Kevin Lee
--- 1. Removed the atsIdentGroupType item.
---
--- v0.87 06-May-2013 Kevin Lee
--- 1. Modified ATS configuration item.
---
--- v0.88 15-May-2013 Kevin Lee
--- 1. Remove ATS configuration item.
---
--- v0.89 03-June-2013 Kevin Lee
--- 1. Modified name of mib tree.
---
--- v0.90 30-Dec-2013 Kevin Lee
--- 1. Added the ATS return normal trap.
---
--- v0.91 14-Jan-2014 Kevin Lee
--- 1. Modified the trap changed severity leverl.
---
--- v0.92 29-Jan-2014 Kevin Lee
--- 1. The trap added one item.
---
---
ATS-MIB DEFINITIONS ::= BEGIN
IMPORTS
enterprises,Counter,IpAddress
FROM RFC1155-SMI
OBJECT-TYPE
FROM RFC-1212
DisplayString
FROM RFC1213-MIB
TRAP-TYPE
FROM RFC-1215
PositiveInteger,NonNegativeInteger
FROM UPS-MIB;
ats OBJECT IDENTIFIER ::= { enterprises 37662 }
product OBJECT IDENTIFIER ::= { ats 1 }
webAppliance OBJECT IDENTIFIER ::= { product 2 }
atsAgent OBJECT IDENTIFIER ::= { webAppliance 2 }
single OBJECT IDENTIFIER ::= { atsAgent 1 }
atsObjectGroup OBJECT IDENTIFIER ::= { single 1 }
atsTrapGroup OBJECT IDENTIFIER ::= { single 2 }
atsIdentGroup OBJECT IDENTIFIER ::= { atsObjectGroup 1 }
atsInputGroup OBJECT IDENTIFIER ::= { atsObjectGroup 2 }
atsOutputGroup OBJECT IDENTIFIER ::= { atsObjectGroup 3 }
atsHmiSwitchGroup OBJECT IDENTIFIER ::= { atsObjectGroup 4 }
atsMiscellaneousGroup OBJECT IDENTIFIER ::= { atsObjectGroup 5 }
atsControlGroup OBJECT IDENTIFIER ::= { atsObjectGroup 6 }
agentConfig OBJECT IDENTIFIER ::= { atsObjectGroup 7 }
emdStatus OBJECT IDENTIFIER ::= { atsObjectGroup 8 }
emdConfig OBJECT IDENTIFIER ::= { atsObjectGroup 9 }
-- ===========================================================================
--
-- atsIdentification
--
-- The Identification group.
--
-- ===========================================================================
atsIdentGroupModel OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The device model name."
::= { atsIdentGroup 1 }
atsIdentGroupSerialNumber OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The device serial number."
::= { atsIdentGroup 2 }
atsIdentGroupManufacturer OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The device manufacturer name."
::= { atsIdentGroup 3 }
atsIdentGroupFirmwareRevision OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The device firmware revision."
::= { atsIdentGroup 4 }
atsIdentGroupAgentFirmwareRevision OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The agent firmware revision."
::= { atsIdentGroup 5 }
-- ===========================================================================
-- atsInputGroup
--
-- The Input group.
-- ===========================================================================
atsInputGroupPreference OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This shows the Output Source Priority by Source A or Source B."
::= { atsInputGroup 1 }
atsInputGroupSourceAstatus OBJECT-TYPE
SYNTAX INTEGER {
fail(1),
ok(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This field shows the status of the source A. Status included? 'OK','Fail'. 'OK' mean frequency and voltage of Source A are normal."
::= { atsInputGroup 2 }
atsInputGroupSourceAinputVoltage OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The source A input voltage of the ATS input in volts."
::= { atsInputGroup 3 }
atsInputGroupSourceAinputFrequency OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The source A input frequency of the ATS input in 0.1 Hz."
::= { atsInputGroup 4 }
atsInputGroupSourceBstatus OBJECT-TYPE
SYNTAX INTEGER {
fail(1),
ok(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This field shows the status of the source B. Status included? 'OK','Fail'. 'OK' mean frequency and voltage of Source B are normal."
::= { atsInputGroup 5 }
atsInputGroupSourceBinputVoltage OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The source B input voltage of the ATS input in volts."
::= { atsInputGroup 6 }
atsInputGroupSourceBinputFrequency OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The source B input frequency of the ATS input in 0.1 Hz."
::= { atsInputGroup 7 }
atsInputGroupSourceAvoltageUpperLimit OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The source A voltage upper limit of the ATS input in volts."
::= { atsInputGroup 8 }
atsInputGroupSourceAvoltageLowerLimit OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The source A voltage lower limit of the ATS input in volts."
::= { atsInputGroup 9 }
atsInputGroupSourceAfrequencyUpperLimit OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The source A frequency upper limit of the ATS input in 0.1 Hz."
::= { atsInputGroup 10 }
atsInputGroupSourceAfrequencyLowerLimit OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The source A frequency lower limit of the ATS input in 0.1 Hz."
::= { atsInputGroup 11 }
atsInputGroupSourceBvoltageUpperLimit OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The source B voltage upper limit of the ATS input in volts."
::= { atsInputGroup 12 }
atsInputGroupSourceBvoltageLowerLimit OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The source B voltage lower limit of the ATS input in volts."
::= { atsInputGroup 13 }
atsInputGroupSourceBfrequencyUpperLimit OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The source B frequency upper limit of the ATS input in 0.1 Hz."
::= { atsInputGroup 14 }
atsInputGroupSourceBfrequencyLowerLimit OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The source B frequency lower limit of the ATS input in 0.1 Hz."
::= { atsInputGroup 15 }
-- ===========================================================================
-- atsOutputGroup
--
-- Output group.
-- ===========================================================================
atsOutputGroupOutputSource OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Output source is supply by Source A or Source B. Status included? 'Source A','Source B'."
::= { atsOutputGroup 1 }
atsOutputGroupOutputVoltage OBJECT-TYPE
SYNTAX NonNegativeInteger
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Output Voltage in volts."
::= { atsOutputGroup 2 }
atsOutputGroupOutputFequency OBJECT-TYPE
SYNTAX NonNegativeInteger
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The output fequency in 0.1 Hz."
::= { atsOutputGroup 3 }
atsOutputGroupOutputCurrent OBJECT-TYPE
SYNTAX NonNegativeInteger
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The output current in 0.1 A."
::= { atsOutputGroup 4 }
atsOutputGroupLoad OBJECT-TYPE
SYNTAX NonNegativeInteger
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The load in %."
::= { atsOutputGroup 5 }
-- ===========================================================================
-- atsHmiSwitchGroup
--
-- Hmi and switch group
-- ===========================================================================
atsHmiSwitchGroupBuzzer OBJECT-TYPE
SYNTAX INTEGER {
buzzerDisabled(1),
buzzerEnabled(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This field shows the status of the buzzer. Status included? 'Enable','Disable'. "
::= { atsHmiSwitchGroup 1 }
atsHmiSwitchGroupAtsAlarm OBJECT-TYPE
SYNTAX INTEGER {
nothing(1),
atsOccurAlarm(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This shows the alarm occured."
::= { atsHmiSwitchGroup 2 }
atsHmiSwitchGroupAutoReturn OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Auto recover to that setting value when two input source normal."
::= { atsHmiSwitchGroup 3 }
atsHmiSwitchGroupSourceTransferByLoad OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"On: If overload timeout occurred , ATS will tranfer to another source automaticlly. Off:If overload timeout occurred , ATS will turn off the output source."
::= { atsHmiSwitchGroup 4 }
atsHmiSwitchGroupSourceTransferByPhase OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"On: when the transfer of output source occur, the transfer can active if differernce of phase less than setting value Off: Switch transfer immed... whatever difference of phase."
::= { atsHmiSwitchGroup 5 }
-- ===========================================================================
-- atsMiscellaneousGroup
-- ===========================================================================
atsMiscellaneousGroupAtsSystemTemperture OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The ATS system temperture in degree C."
::= { atsMiscellaneousGroup 1 }
atsMiscellaneousGroupSystemMaxCurrent OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The system max current int 0.1 Amp."
::= { atsMiscellaneousGroup 2 }
-- ===========================================================================
-- atsControlGroup
--
-- ===========================================================================
atsControlGroupBuzzerAlarmControl OBJECT-TYPE
SYNTAX INTEGER {
buzzerOff(1),
buzzerOn(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The buzzer alarm control."
::= { atsControlGroup 1}
atsControlGroupManualTransfer OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"User can click this bottom to decide output source supply is Source A or Source B."
::= { atsControlGroup 2}
-- ===========================================================================
--
-- agentConfig
--
-- ===========================================================================
agentConfigIpaddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" The ip address that NMS can identify the managed
device"
::= { agentConfig 1}
agentConfigGateway OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" The default gateway that allow device managed
through routers "
::= { agentConfig 2}
agentConfigSubnetMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Internet address subnet mask"
::= { agentConfig 3}
agentConfigDate OBJECT-TYPE
SYNTAX DisplayString (SIZE (10..10))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The date in agent, format is (dd/mm/yyyy)"
::= { agentConfig 4}
agentConfigTime OBJECT-TYPE
SYNTAX DisplayString (SIZE (8..8))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The time in agent, format is (hh:mm:ss)"
::= { agentConfig 5}
agentConfigHistoryLogFrequency OBJECT-TYPE
SYNTAX INTEGER (1..28800) -- in seconds
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The frequency of the updation of the history log. The value
is in seconds"
::= { agentConfig 6 }
agentConfigExtHistoryLogFrequency OBJECT-TYPE
SYNTAX INTEGER (1..10080) -- in minutes
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The ups parameters are sampled at the rate governed by the
mconfigHistroyLogFrequency. These sampled values are further
conslidated over period of time which is determined by this
object."
::= { agentConfig 7 }
agentConfigPollRate OBJECT-TYPE
SYNTAX INTEGER (1..999) -- in seconds
ACCESS read-write
STATUS mandatory
DESCRIPTION
" The frequency that proxy agent polls the connected
UPS in JBUS protocol. (unit : second)"
::= { agentConfig 8}
agentConfigBaudRate OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The serial port communication speed. only 9600 allowed"
::= { agentConfig 9}
agentConfigDhcpStatue OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable or disable DHCP/BootP capability"
::= { agentConfig 10}
agentConfigTelnetStatue OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable or disable telnet access"
::= { agentConfig 11}
agentConfigTftpStatue OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable or disable network upgrade capability"
::= { agentConfig 12}
agentConfigResetToDefault OBJECT-TYPE
SYNTAX INTEGER {
reset(1),
nothing(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Reset all parameters of ATS to default value"
::= { agentConfig 13}
agentConfigRestart OBJECT-TYPE
SYNTAX INTEGER {
restart(1),
nothing(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Restart ATS"
::= { agentConfig 14}
agentConfigClearAgentLog OBJECT-TYPE
SYNTAX INTEGER {
clear(1),
nothing(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Clear agent log data"
::= { agentConfig 15}
agentConfigClearEventLog OBJECT-TYPE
SYNTAX INTEGER {
clear(1),
nothing(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Clear event log data"
::= { agentConfig 16}
agentConfigClearExtHistoryLog OBJECT-TYPE
SYNTAX INTEGER {
clear(1),
nothing(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Clear extented history log data"
::= { agentConfig 17}
agentConfigClearHistoryLog OBJECT-TYPE
SYNTAX INTEGER {
clear(1),
nothing(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Clear history log data"
::= { agentConfig 18}
agentConfigTrapRetryCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The count of repeat traps to send to NMS before trap
acknowledge received."
::= { agentConfig 19}
agentConfigTrapRetryTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The time between retry traps sned to NMS."
::= { agentConfig 20}
agentConfigTrapAckSignature OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The signature of trap acknowledge."
::= { agentConfig 21}
agentConfigMibVersion OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The version of MIB spec."
::= { agentConfig 22 }
agentConfigTrapsReceiversTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgentConfigTrapsReceiversEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of managers to send traps to. The number of
entries is given by the value of agentConfigNumTrapReceivers"
::= { agentConfig 23}
agentConfigTrapsReceiversEntry OBJECT-TYPE
SYNTAX AgentConfigTrapsReceiversEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The managers to send traps to."
INDEX { trapsIndex}
::= { agentConfigTrapsReceiversTable 1 }
AgentConfigTrapsReceiversEntry ::=
SEQUENCE {
trapsIndex
INTEGER,
trapsReceiverAddr
DisplayString,
receiverCommunityString
DisplayString,
receiverNmsType
INTEGER,
receiverSeverityLevel
INTEGER,
receiverDescription
DisplayString
}
trapsIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to a trap receiver entry."
::= { agentConfigTrapsReceiversEntry 1 }
trapsReceiverAddr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The IP address of the manager to send a trap to."
::= { agentConfigTrapsReceiversEntry 2 }
receiverCommunityString OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..19))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The community name to use in the trap when
sent to the manager."
::= { agentConfigTrapsReceiversEntry 3 }
receiverNmsType OBJECT-TYPE
SYNTAX INTEGER {
none(1),
ats-trap(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The trap group that NMS desired."
::= { agentConfigTrapsReceiversEntry 4 }
receiverSeverityLevel OBJECT-TYPE
SYNTAX INTEGER {
informational(1),
warning(2),
severe(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The severity level of traps to be received by this manager."
::= { agentConfigTrapsReceiversEntry 5 }
receiverDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..31))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Description of trap receivers"
::= { agentConfigTrapsReceiversEntry 6 }
agentConfigAccessControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgentConfigAccessControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of managers which can access ATS with private
community string."
::= { agentConfig 24}
agentConfigAccessControlEntry OBJECT-TYPE
SYNTAX AgentConfigAccessControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The managers."
INDEX { trapsIndex}
::= { agentConfigAccessControlTable 1 }
AgentConfigAccessControlEntry ::=
SEQUENCE {
accessIndex
INTEGER,
accessControlAddr
IpAddress,
accessCommunityString
DisplayString,
accessControlMode
INTEGER
}
accessIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to a access control entry."
::= { agentConfigAccessControlEntry 1 }
accessControlAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The IP address of the manager to access ATS"
::= { agentConfigAccessControlEntry 2 }
accessCommunityString OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..19))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The community name to use in the manager when
access ATS"
::= { agentConfigAccessControlEntry 3 }
accessControlMode OBJECT-TYPE
SYNTAX INTEGER {
readOnly (1),
readWrite (2),
notAccess (3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Access type, only read/Write access type can change parameter
of ATS"
::= { agentConfigAccessControlEntry 4 }
agentConfigDefaultLanguage OBJECT-TYPE
SYNTAX INTEGER {
auto(1),
english(2),
traditionalChinese(3),
simplifiedChinese(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The default languauge for browser, when set to auto(1)
ATS will send page in the language depends on the
request language of browser."
::= { agentConfig 25 }
agentConfigIPv6AddrStatus OBJECT-TYPE
SYNTAX INTEGER {
invalid(1),
valid(2),
manualConfiguration(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The status of IPv6 global address. When the auto-configuration
of IPv6 address is disabled, it shows manual configuration(3).
Otherwise, it shows valid(2) for auto-configured successfully,
or shows invalid(1) for the failure in auto-configured."
::= { agentConfig 26 }
agentConfigIPv6AddrAutoConfig OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The state of IPv6 address auto-configuration. If set to enable(1),
ATS will try to get a valid global/site-local address from IPv6
router or DHCPv6 server on the same link."
::= { agentConfig 27 }
agentConfigIPv6LinkLocalAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The IPv6 link-local address of ATS. It is auto-configured based on
MAC address of ATS."
::= { agentConfig 28 }
agentConfigIPv6GlobalAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The IPv6 global/site-local address of ATS. If change it manually,
the agentConfigIPv6AddrStatus and agentConfigIPv6AddrAutoConfig will
be changed to manual configuration and disabled respectively."
::= { agentConfig 29 }
agentConfigIPv6PrefixlLength OBJECT-TYPE
SYNTAX INTEGER (1..128)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The prefix length of IPv6 global/site-local address.If change it manually,
the agentConfigIPv6AddrStatus and agentConfigIPv6AddrAutoConfig will
be changed to manual configuration and disabled respectively."
::= { agentConfig 30 }
agentConfigIPv6DefaultRouter OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The address of IPv6 default router. If change it manually,
the agentConfigIPv6AddrStatus and agentConfigIPv6AddrAutoConfig will
be changed to manual configuration and disabled respectively."
::= { agentConfig 31 }
-- ===========================================================================
--
-- emdStatus
--
-- ===========================================================================
emdSatatusEmdType OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
disabled(2),
emdHT(3),
emdT(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type of EMD plugged into the port."
::= { emdStatus 1}
emdSatatusTemperature OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The measurement of EMD temperature, in 0.1 degree"
::= { emdStatus 2}
emdSatatusHumidity OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The measurement of EMD humidity, in 0.1 degree"
::= { emdStatus 3}
emdSatatusAlarm1 OBJECT-TYPE
SYNTAX INTEGER {
unknow(1),
disabled(2),
active(3),
inactive(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The EMD alarm-1 status"
::= { emdStatus 4}
emdSatatusAlarm2 OBJECT-TYPE
SYNTAX INTEGER {
unknow(1),
disabled(2),
active(3),
inactive(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The EMD alarm-2 status"
::= { emdStatus 5}
-- ===========================================================================
--
-- emdConfig
--
-- ===========================================================================
usahEmdConfigEmdConfig OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
auto(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable or disable to detect presence of EMD"
::= { emdConfig 1}
emdConfigEmdName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..15))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Description of EMD"
::= { emdConfig 2}
emdConfigTemperature OBJECT IDENTIFIER ::= { emdConfig 3 }
emdConfigTempName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..15))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Description of EMD temperature sensor"
::= { emdConfigTemperature 1}
emdConfigTempHighSetPoint OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The set point for high temperature warning, in degrees"
::= { emdConfigTemperature 2}
emdConfigTempHighStatus OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"To enable/disable high set point check with emd temperature."
::= { emdConfigTemperature 3}
emdConfigTempLowSetPoint OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The set point for low temperature warning, in degrees"
::= { emdConfigTemperature 4}
emdConfigTempLowStatus OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"To enable/disable low set point check with emd temperature."
::= { emdConfigTemperature 5}
emdConfigTempOffset OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The offset to calibrate temperature of EMD, in degrees"
::= { emdConfigTemperature 6}
emdConfigHumidity OBJECT IDENTIFIER ::= { emdConfig 4 }
emdConfigHumidityName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..15))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Description of EMD humidity sensor"
::= { emdConfigHumidity 1}
emdConfigHumidityHighSetPoint OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The set point for high humidity warning, in %"
::= { emdConfigHumidity 2}
emdConfigHumidityHighStatus OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"To enable/disable high set point check with emd humidity."
::= { emdConfigHumidity 3}
emdConfigHumidityLowSetPoint OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The set point for low humidity warning, in %"
::= { emdConfigHumidity 4}
emdConfigHumidityLowStatus OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"To enable/disable low set point check with emd humidity."
::= { emdConfigHumidity 5}
emdConfigHumidityOffset OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The offset to calibrate humidity of EMD, in %"
::= { emdConfigHumidity 6}
emdConfigAlarm1 OBJECT IDENTIFIER ::= { emdConfig 5 }
emdConfigAlarm1Name OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..15))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Description of EMD alarm-1"
::= { emdConfigAlarm1 1}
emdConfigAlarm1Type OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
nomralOpen(2),
normalClose(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The alarm-1 operation type"
::= { emdConfigAlarm1 2 }
emdConfigAlarm2 OBJECT IDENTIFIER ::= { emdConfig 6 }
emdConfigAlarm2Name OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..15))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Description of EMD alarm-2"
::= { emdConfigAlarm2 1}
emdConfigAlarm2Type OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
nomralOpen(2),
normalClose(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The alarm-1 operation type"
::= { emdConfigAlarm2 2 }
-- ===========================================================================
-- atsTrapGroup
--
-- Traps group
-- ===========================================================================
-- This section defines the well-known notifications sent by
-- ATS agents.
-- Care must be taken to insure that no particular notification
-- is sent to a single receiving entity more often than once
-- every five seconds.
atsAtsAlarm TRAP-TYPE
ENTERPRISE atsTrapGroup
DESCRIPTION
"WARNING: ATS Alarm."
::= 1
atsSourceAvoltageAbnormal TRAP-TYPE
ENTERPRISE atsTrapGroup
DESCRIPTION
"WARNING: Source A voltage abnormal."
::= 2
atsSourceBvoltageAbnormal TRAP-TYPE
ENTERPRISE atsTrapGroup
DESCRIPTION
"WARNING: Source B voltage abnormal."
::= 3
atsSourceAfrequencyAbnormal TRAP-TYPE
ENTERPRISE atsTrapGroup
DESCRIPTION
"WARNING: Source A frequency abnormal."
::= 4
atsSourceBfrequencyAbnormal TRAP-TYPE
ENTERPRISE atsTrapGroup
DESCRIPTION
"WARNING: Source B frequency abnormal."
::= 5
atsOutputOverLoad TRAP-TYPE
ENTERPRISE atsTrapGroup
DESCRIPTION
"SEVERE: Output over load."
::= 6
atsWorkPowerAabnormal TRAP-TYPE
ENTERPRISE atsTrapGroup
DESCRIPTION
"SEVERE: Unit fault (Working power A abnormal)."
::= 7
atsWorkPowerBabnormal TRAP-TYPE
ENTERPRISE atsTrapGroup
DESCRIPTION
"SEVERE: Unit fault (Working power B abnormal)."
::= 8
atsOverTemperature TRAP-TYPE
ENTERPRISE atsTrapGroup
DESCRIPTION
"WARNING: Cabinet over temperature."
::= 9
atsDcOffsetAbnormal TRAP-TYPE
ENTERPRISE atsTrapGroup
DESCRIPTION
"SEVERE: Unit fault (Sensor circuit abnormal)."
::= 10
atsEepromAbnormal TRAP-TYPE
ENTERPRISE atsTrapGroup
DESCRIPTION
"SEVERE: Unit fault (EEPROM data abnormal)"
::= 11
atsLcdNotConnect TRAP-TYPE
ENTERPRISE atsTrapGroup
DESCRIPTION
"SEVERE: LCD panel connection abnormal."
::= 12
atsOutputExceedsOverloadTime TRAP-TYPE
ENTERPRISE atsTrapGroup
DESCRIPTION
"SEVERE: Overload time out, Output off, Reset needed."
::= 13
atsInputPhaseDifference TRAP-TYPE
ENTERPRISE atsTrapGroup
DESCRIPTION
"SEVERE: Phase difference between resources exceed user defined value, Output off, Reset needed."
::= 14
atsUserSetOverLoad TRAP-TYPE
ENTERPRISE atsTrapGroup
DESCRIPTION
"WARNING: User defined load pre-alarm."
::= 15
atsAtsAlarmToNormal TRAP-TYPE
ENTERPRISE atsTrapGroup
DESCRIPTION
"INFORMATION: ATS Alarm Normal."
::= 16
atsSourceAvoltageAbnormalToNormal TRAP-TYPE
ENTERPRISE atsTrapGroup
DESCRIPTION
"INFORMATION: Source A Voltage Normal."
::= 17
atsSourceBvoltageAbnormalToNormal TRAP-TYPE
ENTERPRISE atsTrapGroup
DESCRIPTION
"INFORMATION: Source B Voltage Normal."
::= 18
atsSourceAfrequencyAbnormalToNormal TRAP-TYPE
ENTERPRISE atsTrapGroup
DESCRIPTION
"INFORMATION: Source A Frequency Normal."
::= 19
atsSourceBfrequencyAbnormalToNormal TRAP-TYPE
ENTERPRISE atsTrapGroup
DESCRIPTION
"INFORMATION: Source B Frequency Normal."
::= 20
atsOutputOverLoadToNormal TRAP-TYPE
ENTERPRISE atsTrapGroup
DESCRIPTION
"INFORMATION: Output Load Normal."
::= 21
atsWorkPowerAabnormalToNormal TRAP-TYPE
ENTERPRISE atsTrapGroup
DESCRIPTION
"INFORMATION: Unit Normal (Working power A normal)."
::= 22
atsWorkPowerBabnormalToNormal TRAP-TYPE
ENTERPRISE atsTrapGroup
DESCRIPTION
"INFORMATION: Unit Normal (Working power B normal)."
::= 23
atsOverTemperatureToNormal TRAP-TYPE
ENTERPRISE atsTrapGroup
DESCRIPTION
"INFORMATION: Cabinet temperature Normal."
::= 24
atsDcOffsetAbnormalToNormal TRAP-TYPE
ENTERPRISE atsTrapGroup
DESCRIPTION
"INFORMATION: Unit Normal (Sensor circuit normal)."
::= 25
atsEepromAbnormalToNormal TRAP-TYPE
ENTERPRISE atsTrapGroup
DESCRIPTION
"INFORMATION: Unit normal (EEPROM data normal)"
::= 26
atsLcdNotConnectToNormal TRAP-TYPE
ENTERPRISE atsTrapGroup
DESCRIPTION
"INFORMATION: LCD panel connection normal."
::= 27
atsOutputExceedsOverloadTimeToNormal TRAP-TYPE
ENTERPRISE atsTrapGroup
DESCRIPTION
"INFORMATION: Output Load Normal."
::= 28
atsInputPhaseDifferenceToNormal TRAP-TYPE
ENTERPRISE atsTrapGroup
DESCRIPTION
"INFORMATION: Input sources return to normal phase."
::= 29
atsUserSetOverLoadToNormal TRAP-TYPE
ENTERPRISE atsTrapGroup
DESCRIPTION
"INFORMATION: User defined load return to Normal."
::= 30
atsCommunicationLost TRAP-TYPE
ENTERPRISE atsTrapGroup
DESCRIPTION
"SEVERE: Communication to the ATS has been lost. Steps
to reestablish communication are in progress."
::= 31
atsCommunicationEstablished TRAP-TYPE
ENTERPRISE atsTrapGroup
DESCRIPTION
"INFORMATION: Communication with the ATS has been
established."
::= 32
emdTemperatureNotHigh TRAP-TYPE
ENTERPRISE atsTrapGroup
VARIABLES {
emdSatatusTemperature,
emdConfigTempHighSetPoint,
emdConfigTempName
}
DESCRIPTION
"INFORMATION: The temperature of EMD back to normal from high warning."
::= 33
emdTemperatureTooHigh TRAP-TYPE
ENTERPRISE atsTrapGroup
VARIABLES {
emdSatatusTemperature,
emdConfigTempHighSetPoint,
emdConfigTempName
}
DESCRIPTION
"WARNING: The temperature of EMD higher than set point."
::= 34
emdTemperatureNotLow TRAP-TYPE
ENTERPRISE atsTrapGroup
VARIABLES {
emdSatatusTemperature,
emdConfigTempLowSetPoint,
emdConfigTempName
}
DESCRIPTION
"INFORMATION: The temperature of EMD back to normal from low warning."
::= 35
emdTemperatureTooLow TRAP-TYPE
ENTERPRISE atsTrapGroup
VARIABLES {
emdSatatusTemperature,
emdConfigTempLowSetPoint,
emdConfigTempName
}
DESCRIPTION
"WARNING: The temperature of EMD lower than set point."
::= 36
emdHumidityNotHigh TRAP-TYPE
ENTERPRISE atsTrapGroup
VARIABLES {
emdSatatusHumidity,
emdConfigHumidityHighSetPoint,
emdConfigHumidityName
}
DESCRIPTION
"INFORMATION: The humidity of EMD back to normal from high warning."
::= 37
emdHumidityTooHigh TRAP-TYPE
ENTERPRISE atsTrapGroup
VARIABLES {
emdSatatusHumidity,
emdConfigHumidityHighSetPoint,
emdConfigHumidityName
}
DESCRIPTION
"WARNING: The humidity of EMD higher than set point."
::= 38
emdHumidityNotLow TRAP-TYPE
ENTERPRISE atsTrapGroup
VARIABLES {
emdSatatusHumidity,
emdConfigHumidityLowSetPoint,
emdConfigHumidityName
}
DESCRIPTION
"INFORMATION: The humidity of EMD back to normal from low warning."
::= 39
emdHumidityTooLow TRAP-TYPE
ENTERPRISE atsTrapGroup
VARIABLES {
emdSatatusHumidity,
emdConfigHumidityLowSetPoint,
emdConfigHumidityName
}
DESCRIPTION
"WARNING: The humidity of EMD lower than set point."
::= 40
emdAlarm1Normal TRAP-TYPE
ENTERPRISE atsTrapGroup
VARIABLES {
emdConfigAlarm1Type,
emdConfigAlarm1Name
}
DESCRIPTION
"INFORMATION: The status of emd alarm-1 back to normal from active."
::= 41
emdAlarm1Active TRAP-TYPE
ENTERPRISE atsTrapGroup
VARIABLES {
emdConfigAlarm1Type,
emdConfigAlarm1Name
}
DESCRIPTION
"WARNING: The status of emd alarm-1 activated."
::= 42
emdAlarm2Normal TRAP-TYPE
ENTERPRISE atsTrapGroup
VARIABLES {
emdConfigAlarm2Type,
emdConfigAlarm2Name
}
DESCRIPTION
"INFORMATION: The status of emd alarm-2 back to normal from active."
::= 43
emdAlarm2Active TRAP-TYPE
ENTERPRISE atsTrapGroup
VARIABLES {
emdConfigAlarm2Type,
emdConfigAlarm2Name
}
DESCRIPTION
"WARNING: The status of emd alarm-2 activated."
::= 44
END
|