summaryrefslogtreecommitdiff
path: root/MIBS/adva/F3-AMP-MIB
blob: 070971afb809919c5d0096e94b94024110df0fa4 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
F3-AMP-MIB DEFINITIONS ::= BEGIN

IMPORTS
    MODULE-COMPLIANCE, OBJECT-GROUP 
             FROM SNMPv2-CONF
    MODULE-IDENTITY, OBJECT-TYPE, Integer32, Unsigned32, IpAddress
             FROM SNMPv2-SMI
    TruthValue, RowStatus, StorageType, DisplayString,
    DateAndTime, VariablePointer, TEXTUAL-CONVENTION
             FROM SNMPv2-TC
    fsp150cm
             FROM  ADVA-MIB 
    VlanId
             FROM  CM-COMMON-MIB
    IpSourceAddrType, IpManagementTunnelType, IpManagementTunnelEncapsulationType
             FROM  CM-IP-MIB;

f3AMPMIB MODULE-IDENTITY
    LAST-UPDATED        "201209310000Z"
    ORGANIZATION    "ADVA Optical Networking"
    CONTACT-INFO
            "        Jakub Zalewski
                     ADVA Optical Networking, Inc.
                Tel: +48 58 7716 411
             E-mail: jzalewski@advaoptical.com
             Postal: ul. Slaska 35/37
                     81-310 Gdynia, Poland"
    DESCRIPTION
            "This module defines the Automatic Management Provisioning MIB definitions
             used by the F3 (FSP150CM/CC) product lines.  
             Copyright (C) ADVA Optical Networking."
    REVISION        "201209300000Z"
    DESCRIPTION
        "
         Notes from release 201209300000Z,
         (1)MIB version ready for release FSP150CC 5.6CC." 

    ::= {fsp150cm 24}

--
-- Textual Conventions
--
AMPRole ::= TEXTUAL-CONVENTION
    STATUS       current
    DESCRIPTION
        "Defines client or server role."
    SYNTAX       INTEGER {
                   client (1),
                   server (2)
                 }

AMPStatus ::= TEXTUAL-CONVENTION
    STATUS       current
    DESCRIPTION
        "Defines AMP Status."
    SYNTAX       INTEGER {
                   notAvailable (1),
                   disabled (2),
                   associatingActive (3),
                   associatingPassive (4),
                   associated (5),
                   noPeer (6)
                 }

AMPConfigStatus ::= TEXTUAL-CONVENTION
    STATUS       current
    DESCRIPTION
        "Defines AMP Configuration Status."
    SYNTAX       INTEGER {
                   none (1),           -- none
                   provision (2),      -- provision request sent to Client
                   noPeer (3),         -- no EFM peer
                   request (4),        -- provisioning request received by Client
                   configSuccess (5),  -- configuration succeeded on Client
                   configFail (6),     -- congiguration failed on Client
                   timeout (7)         -- response timeout
                 }

AMPProtocol ::= TEXTUAL-CONVENTION
    STATUS       current
    DESCRIPTION
        "Defines protocol over which AMP messages are sent."
    SYNTAX       INTEGER {
                   efmOam (1)
                 }

AMPConfigAction ::= TEXTUAL-CONVENTION
    STATUS       current
    DESCRIPTION
        "Defines Actions available for f3AmpConfig object"
    SYNTAX       INTEGER {
                   noAction (1),
                   clearStats (2)
                 }

-- 
-- OID definitions
-- 
f3AmpConfigObjects      OBJECT IDENTIFIER ::= {f3AMPMIB 1}
f3AmpStatsObjects       OBJECT IDENTIFIER ::= {f3AMPMIB 2}
f3AmpConformance        OBJECT IDENTIFIER ::= {f3AMPMIB 3}


--
--  AMP Client/Server Configuration table
--
f3AmpConfigTable  OBJECT-TYPE
    SYNTAX      SEQUENCE OF F3AmpConfigEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
            "A list of entries corresponding to Automatic Management Provisioning
             configuration instance for configuration purposes."
    ::= { f3AmpConfigObjects 1 }

f3AmpConfigEntry OBJECT-TYPE
    SYNTAX      F3AmpConfigEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
            "A conceptual row in the f3AmpConfigTable."
    INDEX { f3AmpConfigIndex }
    ::= { f3AmpConfigTable 1 }

F3AmpConfigEntry ::= SEQUENCE {
    f3AmpConfigIndex                           Integer32,
    f3AmpConfigRole                            AMPRole,
    f3AmpConfigProtocol                        AMPProtocol,
    f3AmpConfigEnabled                         TruthValue,
    f3AmpConfigPort                            VariablePointer,
    f3AmpConfigStatus                          AMPStatus,
    f3AmpConfigRemSysName                      DisplayString,
    f3AmpConfigRemSysIpAddr                    IpAddress,
    f3AmpConfigRemSysIpMask                    IpAddress,
    f3AmpConfigRemSysDefGateway                IpAddress,
    f3AmpConfigRemSysSNMPV1IfName              DisplayString,
    f3AmpConfigRemSysSrcIpAddrType             IpSourceAddrType,
    f3AmpConfigRemSysSrcIpAddrIfName           DisplayString,
    f3AmpConfigRemTunnelIndex                  Integer32,
    f3AmpConfigRemTunnelName                   DisplayString,
    f3AmpConfigRemTunnelType                   IpManagementTunnelType, 
    f3AmpConfigRemTunnelIpAddr                 IpAddress,
    f3AmpConfigRemTunnelIpMask                 IpAddress,
    f3AmpConfigRemTunnelVlanId                 VlanId,
    f3AmpConfigRemTunnelSVlanId                VlanId,
    f3AmpConfigRemTunnelSVlanIdEnabled         TruthValue,
    f3AmpConfigRemTunnelRip2PktsEnabled        TruthValue,
    f3AmpConfigRemTunnelCOS                    Integer32,
    f3AmpConfigRemTunnelCIR                    Unsigned32,
    f3AmpConfigRemTunnelEIR                    Unsigned32,
    f3AmpConfigRemTunnelBufferSize             Unsigned32,
    f3AmpConfigRemTunnelEncapType              IpManagementTunnelEncapsulationType,
    f3AmpConfigRemTunnelMtu                    Integer32,
    f3AmpConfigAction                          AMPConfigAction,
    f3AmpConfigStorageType                     StorageType,
    f3AmpConfigRowStatus                       RowStatus
}

f3AmpConfigIndex OBJECT-TYPE
    SYNTAX        Integer32 (1..255)
    MAX-ACCESS    not-accessible
    STATUS        current
    DESCRIPTION
         "An integer index value used to uniquely identify
             this AMP Config within the System."
    ::= { f3AmpConfigEntry 1 }

f3AmpConfigRole OBJECT-TYPE
    SYNTAX        AMPRole
    MAX-ACCESS    read-create
    STATUS        current
    DESCRIPTION
         "Configures AMP instance to be either Client or Server."
    ::= { f3AmpConfigEntry 2 }

f3AmpConfigProtocol OBJECT-TYPE
    SYNTAX        AMPProtocol
    MAX-ACCESS    read-create
    STATUS        current
    DESCRIPTION
         "Configures protocol over which AMP message will be transported."
    ::= { f3AmpConfigEntry 3 }

f3AmpConfigEnabled OBJECT-TYPE
    SYNTAX        TruthValue
    MAX-ACCESS    read-create
    STATUS        current
    DESCRIPTION
         "Enables or Disables AMP on a Port."
    ::= { f3AmpConfigEntry 4 }

f3AmpConfigPort OBJECT-TYPE
    SYNTAX        VariablePointer
    MAX-ACCESS    read-create
    STATUS        current
    DESCRIPTION
         "Port on which AMP Server or Client will operate. This port will 
          transmit/receive AMP messages. The AMP can operate on Access Ports and
          Network Port and f3AmpConfigPort shall point to either cmEthernetAccPortIndex 
          or cmEthernetNetPortIndex."
    ::= { f3AmpConfigEntry 5 }

f3AmpConfigStatus OBJECT-TYPE
    SYNTAX        AMPStatus
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
         "The Status of AMP."
    ::= { f3AmpConfigEntry 6 }

f3AmpConfigRemSysName OBJECT-TYPE
    SYNTAX        DisplayString
    MAX-ACCESS    read-create
    STATUS        current
    DESCRIPTION
         "When f3AmpConfigRole is 'server' this object specifies sysName which is sent
          in a AMP message to be configfured on a AMP Client device.
          When f3AmpConfigRole is 'client' this object is read-only and shows the sysName
          value which was received from the AMP Server."
    ::= { f3AmpConfigEntry 7 }

f3AmpConfigRemSysIpAddr OBJECT-TYPE
    SYNTAX        IpAddress
    MAX-ACCESS    read-create
    STATUS        current
    DESCRIPTION
         "When f3AmpConfigRole is 'server' this object specifies System IP address 
          which is sent in a AMP message to be configfured on a AMP Client device.
          When f3AmpConfigRole is 'client' this object is read-only and shows the 
          System IP address value which was received from the AMP Server."
    ::= { f3AmpConfigEntry 8 }

f3AmpConfigRemSysIpMask OBJECT-TYPE
    SYNTAX        IpAddress
    MAX-ACCESS    read-create
    STATUS        current
    DESCRIPTION
         "When f3AmpConfigRole is 'server' this object specifies System IP mask 
          which is sent in a AMP message to be configfured on a AMP Client device.
          When f3AmpConfigRole is 'client' this object is read-only and shows the 
          System IP mask value which was received from the AMP Server."
    ::= { f3AmpConfigEntry 9 }

f3AmpConfigRemSysDefGateway OBJECT-TYPE
    SYNTAX        IpAddress
    MAX-ACCESS    read-create
    STATUS        current
    DESCRIPTION
         "When f3AmpConfigRole is 'server' this object specifies System Default Gateway 
          which is sent in a AMP message to be configfured on a AMP Client device.
          When f3AmpConfigRole is 'client' this object is read-only and shows the 
          System Default Gateway value which was received from the AMP Server."
    ::= { f3AmpConfigEntry 10 }

f3AmpConfigRemSysSNMPV1IfName OBJECT-TYPE
    SYNTAX        DisplayString
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
         "When f3AmpConfigRole is 'server' this object specifies 
          System SNMPV1 Interface Name which is sent
          in a AMP message to be configfured on a AMP Client device.
          When f3AmpConfigRole is 'client' this object shows the 
          System SNMPV1 Interface Name value which was received from the AMP Server."
    ::= { f3AmpConfigEntry 11 }

f3AmpConfigRemSysSrcIpAddrType OBJECT-TYPE
    SYNTAX        IpSourceAddrType
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
         "When f3AmpConfigRole is 'server' this object specifies System Source IP Address 
          type which is sent in an AMP message to be configfured on an AMP Client device.
          When f3AmpConfigRole is 'client' this object is read-only and shows the 
          System Source IP Address Type value which was received from the AMP Server."
    ::= { f3AmpConfigEntry 12 }

f3AmpConfigRemSysSrcIpAddrIfName OBJECT-TYPE
    SYNTAX        DisplayString
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
         "When f3AmpConfigRole is 'server' this object specifies System Source IP
          Interface name sent in an AMP message to be configured on an AMP Client device.
          When f3AmpConfigRole is 'client' this object shows the  SystemSource IP Interface 
          value which was received from the AMP Server."
    ::= { f3AmpConfigEntry 13 }

f3AmpConfigRemTunnelIndex OBJECT-TYPE
    SYNTAX        Integer32 (0..255)
    MAX-ACCESS    read-create
    STATUS        current
    DESCRIPTION
         "When f3AmpConfigRole is 'server' this object specifies 
          index of a Management Tunnel which is sent
          in an AMP message to be configfured on an AMP Client device.
          When f3AmpConfigRole is 'client' this object is read-only and shows the 
          index of a Management Tunnel which was received from the AMP Server."
    ::= { f3AmpConfigEntry 14 }

f3AmpConfigRemTunnelName OBJECT-TYPE
    SYNTAX        DisplayString
    MAX-ACCESS    read-create
    STATUS        current
    DESCRIPTION
         "When f3AmpConfigRole is 'server' this object specifies 
          a Management Tunnel name which is sent
          in an AMP message to be configfured on an AMP Client device.
          When f3AmpConfigRole is 'client' this object is read-only and shows the 
          Management Tunnel name which was received from the AMP Server."
    ::= { f3AmpConfigEntry 15 }

f3AmpConfigRemTunnelType OBJECT-TYPE
    SYNTAX        IpManagementTunnelType 
    MAX-ACCESS    read-create
    STATUS        current
    DESCRIPTION
         "When f3AmpConfigRole is 'server' this object specifies 
          a Management Tunnel type value which is sent
          in an AMP message to be configfured on an AMP Client device.
          When f3AmpConfigRole is 'client' this object is read-only and shows the 
          Management Tunnel type value which was received from the AMP Server."
    ::= { f3AmpConfigEntry 16 }

f3AmpConfigRemTunnelIpAddr OBJECT-TYPE
    SYNTAX        IpAddress
    MAX-ACCESS    read-create
    STATUS        current
    DESCRIPTION
         "When f3AmpConfigRole is 'server' this object specifies 
          IP Address of a Management Tunnel which is sent
          in an AMP message to be configfured on an AMP Client device.
          When f3AmpConfigRole is 'client' this object is read-only and shows the 
          IP Address of a Management Tunnel which was received from the AMP Server."
    ::= { f3AmpConfigEntry 17 }

f3AmpConfigRemTunnelIpMask OBJECT-TYPE
    SYNTAX        IpAddress
    MAX-ACCESS    read-create
    STATUS        current
    DESCRIPTION
         "When f3AmpConfigRole is 'server' this object specifies 
          IP Mask of a Management Tunnel which is sent
          in an AMP message to be configfured on an AMP Client device.
          When f3AmpConfigRole is 'client' this object is read-only and shows the 
          IP Mask of a Management Tunnel which was received from the AMP Server."
    ::= { f3AmpConfigEntry 18 }

f3AmpConfigRemTunnelVlanId OBJECT-TYPE
    SYNTAX        VlanId
    MAX-ACCESS    read-create
    STATUS        current
    DESCRIPTION
         "When f3AmpConfigRole is 'server' this object specifies 
          VlanId of a Management Tunnel which is sent
          in an AMP message to be configfured on an AMP Client device.
          When f3AmpConfigRole is 'client' this object is read-only and shows the 
          VlanId of a Management Tunnel which was received from the AMP Server."
    ::= { f3AmpConfigEntry 19 }

f3AmpConfigRemTunnelSVlanId OBJECT-TYPE
    SYNTAX        VlanId
    MAX-ACCESS    read-create
    STATUS        current
    DESCRIPTION
         "When f3AmpConfigRole is 'server' this object specifies 
          S-TAG VlanId of a Management Tunnel which is sent
          in an AMP message to be configfured on an AMP Client device.
          When f3AmpConfigRole is 'client' this object is read-only and shows the 
          S-TAG VlanId of a Management Tunnel which was received from the AMP Server."
    ::= { f3AmpConfigEntry 20 }

f3AmpConfigRemTunnelSVlanIdEnabled OBJECT-TYPE
    SYNTAX        TruthValue
    MAX-ACCESS    read-create
    STATUS        current
    DESCRIPTION
         "When f3AmpConfigRole is 'server' this object specifies 
          a Management Tunnel S-TAG VlanId Enable value which is sent
          in an AMP message to be configfured on an AMP Client device.
          When f3AmpConfigRole is 'client' this object is read-only and shows the 
          a Management Tunnel S-TAG VlanId Enabled value which was received 
          from the AMP Server."
    ::= { f3AmpConfigEntry 21 }

f3AmpConfigRemTunnelRip2PktsEnabled OBJECT-TYPE
    SYNTAX        TruthValue
    MAX-ACCESS    read-create
    STATUS        current
    DESCRIPTION
         "When f3AmpConfigRole is 'server' this object specifies 
          a Management Tunnel RIP2 Packates Enabled value which is sent
          in an AMP message to be configfured on an AMP Client device.
          When f3AmpConfigRole is 'client' this object is read-only and shows the 
          a Management Tunnel RIP2 Packates Enabled value which was received 
          from the AMP Server."
    ::= { f3AmpConfigEntry 22 }

f3AmpConfigRemTunnelCOS OBJECT-TYPE
    SYNTAX        Integer32 (0..7)
    MAX-ACCESS    read-create
    STATUS        current
    DESCRIPTION
         "When f3AmpConfigRole is 'server' this object specifies 
          COS of a Management Tunnel which is sent
          in an AMP message to be configfured on an AMP Client device.
          When f3AmpConfigRole is 'client' this object is read-only and shows the 
          COS of a Management Tunnel which was received from the AMP Server."
    ::= { f3AmpConfigEntry 23 }

f3AmpConfigRemTunnelCIR OBJECT-TYPE
    SYNTAX        Unsigned32
    MAX-ACCESS    read-create
    STATUS        current
    DESCRIPTION
         "When f3AmpConfigRole is 'server' this object specifies 
          CIR of a Management Tunnel which is sent
          in an AMP message to be configfured on an AMP Client device.
          When f3AmpConfigRole is 'client' this object is read-only and shows the 
          CIR of a Management Tunnel which was received from the AMP Server."
    ::= { f3AmpConfigEntry 24 }

f3AmpConfigRemTunnelEIR OBJECT-TYPE
    SYNTAX        Unsigned32
    MAX-ACCESS    read-create
    STATUS        current
    DESCRIPTION
         "When f3AmpConfigRole is 'server' this object specifies 
          EIR of a Management Tunnel which is sent
          in an AMP message to be configfured on an AMP Client device.
          When f3AmpConfigRole is 'client' this object is read-only and shows the 
          EIR of a Management Tunnel which was received from the AMP Server."
    ::= { f3AmpConfigEntry 25 }

f3AmpConfigRemTunnelBufferSize OBJECT-TYPE
    SYNTAX        Unsigned32
    MAX-ACCESS    read-create
    STATUS        current
    DESCRIPTION
         "When f3AmpConfigRole is 'server' this object specifies 
          Buffer Size of a Management Tunnel which is sent
          in an AMP message to be configfured on an AMP Client device.
          When f3AmpConfigRole is 'client' this object is read-only and shows the 
          Buffer Size of a Management Tunnel which was received from the AMP Server."
    ::= { f3AmpConfigEntry 26 }

f3AmpConfigRemTunnelEncapType OBJECT-TYPE
    SYNTAX        IpManagementTunnelEncapsulationType
    MAX-ACCESS    read-create
    STATUS        current
    DESCRIPTION
         "When f3AmpConfigRole is 'server' this object specifies 
          Encapsulation Type of a Management Tunnel which is sent
          in an AMP message to be configfured on an AMP Client device.
          When f3AmpConfigRole is 'client' this object is read-only and shows the 
          Encapsulation Type of a Management Tunnel which was received from 
          the AMP Server."
    ::= { f3AmpConfigEntry 27 }

f3AmpConfigRemTunnelMtu OBJECT-TYPE
    SYNTAX        Integer32
    MAX-ACCESS    read-create
    STATUS        current
    DESCRIPTION
         "When f3AmpConfigRole is 'server' this object specifies 
          MTU of a Management Tunnel which is sent
          in an AMP message to be configfured on an AMP Client device.
          When f3AmpConfigRole is 'client' this object is read-only and shows the 
          MTU of a Management Tunnel which was received from the AMP Server."
    ::= { f3AmpConfigEntry 28 }

f3AmpConfigAction OBJECT-TYPE
    SYNTAX        AMPConfigAction
    MAX-ACCESS    read-create
    STATUS        current
    DESCRIPTION
         "This object may be used to initiate user action on this AMP Config instance."
    ::= { f3AmpConfigEntry 29 }

f3AmpConfigStorageType OBJECT-TYPE
    SYNTAX        StorageType
    MAX-ACCESS    read-create
    STATUS        current
    DESCRIPTION
            "The type of storage configured for this entry."
    ::= { f3AmpConfigEntry 30 }

f3AmpConfigRowStatus OBJECT-TYPE
    SYNTAX        RowStatus
    MAX-ACCESS    read-create
    STATUS        current
    DESCRIPTION
           "The status of this row.  An entry MUST NOT exist in the 
            active state unless all objects in the entry have an 
            appropriate value, as described
            in the description clause for each writable object.

            The values of f3AmpConfigRowStatus supported are
            createAndGo(4) and destroy(6).  All mandatory attributes
            must be specified in a single SNMP SET request with
            neRowStatus value as createAndGo(4).
            Upon successful row creation, this object has a
            value of active(1).

            The f3AmpConfigRowStatus object may be modified if
            the associated instance of this object is equal to active(1)."

    ::= { f3AmpConfigEntry 31 }

--
--  AMP Stats
--
f3AmpStatsTable  OBJECT-TYPE
    SYNTAX      SEQUENCE OF F3AmpStatsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
            "A list of entries corresponding to Automatic Management Provisioning
             Statistics"
    ::= { f3AmpStatsObjects 1 }

f3AmpStatsEntry OBJECT-TYPE
    SYNTAX      F3AmpStatsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
            "A conceptual row in the f3AmpStatsTable."
    INDEX { f3AmpConfigIndex }
    ::= { f3AmpStatsTable 1 }

F3AmpStatsEntry ::= SEQUENCE {
    f3AmpStatsProvDataTx                           Unsigned32,
    f3AmpStatsProvDataRx                           Unsigned32,
    f3AmpStatsProvRequestTx                        Unsigned32,
    f3AmpStatsProvRequestRx                        Unsigned32,
    f3AmpStatsConfigSuccessTx                      Unsigned32,
    f3AmpStatsConfigSuccessRx                      Unsigned32,
    f3AmpStatsConfigFailTx                         Unsigned32,
    f3AmpStatsConfigFailRx                         Unsigned32,
    f3AmpStatsSpuriousMessageRx                    Unsigned32,
    f3AmpStatsTimeoutRx                            Unsigned32,
    f3AmpStatsLastRxStatus                         AMPConfigStatus,
    f3AmpStatsRxTimeStamp                          DateAndTime,
    f3AmpStatsLastTxStatus                         AMPConfigStatus,
    f3AmpStatsTxTimeStamp                          DateAndTime
}

f3AmpStatsProvDataTx OBJECT-TYPE
    SYNTAX        Unsigned32
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
          "The number of Provisioning Data messages sent by AMP Server."
    ::= { f3AmpStatsEntry 1 }

f3AmpStatsProvDataRx OBJECT-TYPE
    SYNTAX        Unsigned32
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
          "The number of Provisioning Data messages received by AMP Client."
    ::= { f3AmpStatsEntry 2 }

f3AmpStatsProvRequestTx OBJECT-TYPE
    SYNTAX        Unsigned32
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
          "The number of Provisioning Request messages sent by AMP Client."
    ::= { f3AmpStatsEntry 3 }

f3AmpStatsProvRequestRx OBJECT-TYPE
    SYNTAX        Unsigned32
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
          "The number of Provisioning Request received sent by AMP Server."
    ::= { f3AmpStatsEntry 4 }

f3AmpStatsConfigSuccessTx OBJECT-TYPE
    SYNTAX        Unsigned32
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
          "The number of Configuration Success messages sent sent by AMP Client."
    ::= { f3AmpStatsEntry 5 }

f3AmpStatsConfigSuccessRx OBJECT-TYPE
    SYNTAX        Unsigned32
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
          "The number of Configuration Success messages received by AMP Server."
    ::= { f3AmpStatsEntry 6 }

f3AmpStatsConfigFailTx OBJECT-TYPE
    SYNTAX        Unsigned32
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
          "The number of Configuration Success messages received by AMP Client."
    ::= { f3AmpStatsEntry 7 }

f3AmpStatsConfigFailRx OBJECT-TYPE
    SYNTAX        Unsigned32
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
          "The number of Configuration Success messages received by AMP Server."
    ::= { f3AmpStatsEntry 8 }

f3AmpStatsSpuriousMessageRx OBJECT-TYPE
    SYNTAX        Unsigned32
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
          "The number of Spurious messages received by AMP Client or Server"
    ::= { f3AmpStatsEntry 9 }

f3AmpStatsTimeoutRx OBJECT-TYPE
    SYNTAX        Unsigned32
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
          "The number of messages which were not received within the time out value.
           AMP Client can time out while waiting for Prov Data message. 
           AMP Server can time out while waiting for Config Fail or Config Success
           message."
    ::= { f3AmpStatsEntry 10 }

f3AmpStatsLastRxStatus OBJECT-TYPE
    SYNTAX        AMPConfigStatus
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
          "Last received Configuration Status."
    ::= { f3AmpStatsEntry 11 }

f3AmpStatsRxTimeStamp OBJECT-TYPE
    SYNTAX        DateAndTime
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
          "Time of last received Configuration Status."
    ::= { f3AmpStatsEntry 12 }

f3AmpStatsLastTxStatus OBJECT-TYPE
    SYNTAX        AMPConfigStatus
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
          "Last sent Configuration Status."
    ::= { f3AmpStatsEntry 13 }

f3AmpStatsTxTimeStamp OBJECT-TYPE
    SYNTAX        DateAndTime
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
          "Time of last sent Configuration Status."
    ::= { f3AmpStatsEntry 14 }

--
-- Conformance
--
f3AmpCompliances OBJECT IDENTIFIER ::= {f3AmpConformance 1}
f3AmpGroups      OBJECT IDENTIFIER ::= {f3AmpConformance 2}

f3AmpCompliance MODULE-COMPLIANCE
    STATUS  current
    DESCRIPTION
            "Describes the requirements for conformance to the F3-AMP-MIB compilance."
    MODULE  -- this module
        MANDATORY-GROUPS {
              f3AmpConfigGroup, f3AmpStatsGroup
        }
    ::= { f3AmpCompliances 1 }

f3AmpConfigGroup OBJECT-GROUP
   OBJECTS {
      f3AmpConfigRole,
      f3AmpConfigProtocol,
      f3AmpConfigEnabled,
      f3AmpConfigPort,
      f3AmpConfigStatus,
      f3AmpConfigRemSysName,
      f3AmpConfigRemSysIpAddr,
      f3AmpConfigRemSysIpMask,
      f3AmpConfigRemSysDefGateway,
      f3AmpConfigRemSysSNMPV1IfName,
      f3AmpConfigRemSysSrcIpAddrType,
      f3AmpConfigRemSysSrcIpAddrIfName,
      f3AmpConfigRemTunnelIndex,
      f3AmpConfigRemTunnelName,
      f3AmpConfigRemTunnelType,
      f3AmpConfigRemTunnelIpAddr,
      f3AmpConfigRemTunnelIpMask,
      f3AmpConfigRemTunnelVlanId,
      f3AmpConfigRemTunnelSVlanId,
      f3AmpConfigRemTunnelSVlanIdEnabled,
      f3AmpConfigRemTunnelRip2PktsEnabled,
      f3AmpConfigRemTunnelCOS,
      f3AmpConfigRemTunnelCIR,
      f3AmpConfigRemTunnelEIR,
      f3AmpConfigRemTunnelBufferSize,
      f3AmpConfigRemTunnelEncapType,
      f3AmpConfigRemTunnelMtu,
      f3AmpConfigAction,
      f3AmpConfigStorageType,
      f3AmpConfigRowStatus
   }
   STATUS  current
   DESCRIPTION
             "A collection of objects used to manage the AMP Configuration."
    ::= { f3AmpGroups 1 }

f3AmpStatsGroup OBJECT-GROUP
   OBJECTS {
      f3AmpStatsProvDataTx,
      f3AmpStatsProvDataRx,
      f3AmpStatsProvRequestTx,
      f3AmpStatsProvRequestRx,
      f3AmpStatsConfigSuccessTx,
      f3AmpStatsConfigSuccessRx,
      f3AmpStatsConfigFailTx,
      f3AmpStatsConfigFailRx,
      f3AmpStatsSpuriousMessageRx,
      f3AmpStatsTimeoutRx,
      f3AmpStatsLastRxStatus,
      f3AmpStatsRxTimeStamp,
      f3AmpStatsLastTxStatus,
      f3AmpStatsTxTimeStamp
   }
   STATUS  current
   DESCRIPTION
             "A collection of objects used to manage the AMP Statistics."
    ::= { f3AmpGroups 2 }

END