diff options
Diffstat (limited to 'MIBS/westmountainradio')
| -rw-r--r-- | MIBS/westmountainradio/RMCU | 523 |
1 files changed, 523 insertions, 0 deletions
diff --git a/MIBS/westmountainradio/RMCU b/MIBS/westmountainradio/RMCU new file mode 100644 index 0000000..96ed893 --- /dev/null +++ b/MIBS/westmountainradio/RMCU @@ -0,0 +1,523 @@ +-- MIB. Import this into your MIB Browser software. +-- This is for West Mountain Radio RIGrunner 4005i + +RMCU DEFINITIONS ::= BEGIN + +IMPORTS + --enterprises, IpAddress, Gauge, TimeTicks FROM RFC1155-SMI + DisplayString FROM RFC1213-MIB + OBJECT-TYPE FROM RFC-1212 + TEXTUAL-CONVENTION FROM SNMPv2-TC + NOTIFICATION-TYPE, Gauge32, Integer32, enterprises, MODULE-IDENTITY FROM SNMPv2-SMI + TRAP-TYPE FROM RFC-1215; + +rr4005i MODULE-IDENTITY + LAST-UPDATED "201710111300Z" + ORGANIZATION "West Mountain Radio" + CONTACT-INFO "www.westmountainradio.com" + DESCRIPTION "West Mountain Radio RIGrunner 4005i" + REVISION "201710111300Z" + DESCRIPTION "Revision" + ::= { enterprises 15117 1 } + +wmr OBJECT IDENTIFIER ::= { enterprises 15117 } + +product OBJECT IDENTIFIER ::= { rr4005i 1 } +control OBJECT IDENTIFIER ::= { rr4005i 2 } +control-ints OBJECT IDENTIFIER ::= { rr4005i 4 } +traps OBJECT IDENTIFIER ::= { rr4005i 3 } + +-- ON-OFF ::= INTEGER { ON(1), OFF(0) } + +FixedDiv1000 ::= TEXTUAL-CONVENTION + DISPLAY-HINT "d-3" + STATUS current + DESCRIPTION "Fixed point, thousandths" + SYNTAX Integer32 + +name OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Unit name" + ::= { product 1 } + + +version OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Software and hardware version" + ::= { product 2 } + +build-date OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Date of software was built" + ::= { product 3 } + + + +analog1name OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Name of analog input #1" + ::= { control 1 } + +analog1val OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Value of analog input #1" + ::= { control 2 } + +analog2name OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Name of analog input #2" + ::= { control 3 } + +analog2val OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Value of analog input #2" + ::= { control 4 } + +analog3name OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Name of analog input #3" + ::= { control 5 } + +analog3val OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Value of analog input #3" + ::= { control 6 } + +analog4name OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Name of analog input #4" + ::= { control 7 } + +analog4val OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Value of analog input #4" + ::= { control 8 } + +analog5name OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Name of analog input #5" + ::= { control 9 } + +analog5val OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Value of analog input #5" + ::= { control 10 } + +analog6name OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Name of analog input #6" + ::= { control 11 } + +analog6val OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Value of analog input #6" + ::= { control 12 } + + + + + +digout1name OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Name of digital output #1" + ::= { control 65 } + +digout1val OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Value of digital output #1" + ::= { control 66 } + +digout2name OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Name of digital output #2" + ::= { control 67 } + +digout2val OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Value of digital output #2" + ::= { control 68 } + +digout3name OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Name of digital output #3" + ::= { control 69 } + +digout3val OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Value of digital output #3" + ::= { control 70 } + +digout4name OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Name of digital output #4" + ::= { control 71 } + +digout4val OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Value of digital output #4" + ::= { control 72 } + +digout5name OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Name of digital output #5" + ::= { control 73 } + +digout5val OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Value of digital output #5" + ::= { control 74 } + + + + + + + + + + +analog1val-int OBJECT-TYPE + SYNTAX FixedDiv1000 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Value of analog input #1" + ::= { control-ints 1 } + +analog2val-int OBJECT-TYPE + SYNTAX FixedDiv1000 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Value of analog input #2" + ::= { control-ints 2 } + +analog3val-int OBJECT-TYPE + SYNTAX FixedDiv1000 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Value of analog input #3" + ::= { control-ints 3 } + +analog4val-int OBJECT-TYPE + SYNTAX FixedDiv1000 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Value of analog input #4" + ::= { control-ints 4 } + +analog5val-int OBJECT-TYPE + SYNTAX FixedDiv1000 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Value of analog input #5" + ::= { control-ints 5 } + +analog6val-int OBJECT-TYPE + SYNTAX FixedDiv1000 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Value of analog input #6" + ::= { control-ints 6 } + + + + + + + + +trap-auth NOTIFICATION-TYPE + STATUS current + DESCRIPTION + "Trap caused by authorization failure" + ::= {traps 1} + +trap-analog-over1 NOTIFICATION-TYPE + OBJECTS {name, analog1val} + STATUS current + DESCRIPTION + "Trap caused by analog input #1 being over threshold" + ::= {traps 2} + +trap-analog-over2 NOTIFICATION-TYPE + OBJECTS {name, analog2val} + STATUS current + DESCRIPTION + "Trap caused by analog input #2 being over threshold" + ::= {traps 3} + +trap-analog-over3 NOTIFICATION-TYPE + OBJECTS {name, analog3val} + STATUS current + DESCRIPTION + "Trap caused by analog input #3 being over threshold" + ::= {traps 4} + +trap-analog-over4 NOTIFICATION-TYPE + OBJECTS {name, analog4val} + STATUS current + DESCRIPTION + "Trap caused by analog input #4 being over threshold" + ::= {traps 5} + +trap-analog-over5 NOTIFICATION-TYPE + OBJECTS {name, analog5val} + STATUS current + DESCRIPTION + "Trap caused by analog input #5 being over threshold" + ::= {traps 6} + +trap-analog-over6 NOTIFICATION-TYPE + OBJECTS {name, analog6val} + STATUS current + DESCRIPTION + "Trap caused by analog input #6 being over threshold" + ::= {traps 7} + + + + + + +trap-analog-under6 NOTIFICATION-TYPE + OBJECTS {name, analog6val} + STATUS current + DESCRIPTION + "Trap caused by analog input #6 being under threshold" + ::= {traps 23} + + +trap-poweron NOTIFICATION-TYPE + OBJECTS {name} + STATUS current + DESCRIPTION + "Trap caused by power-on" + ::= {traps 34} + + + + +trap-test NOTIFICATION-TYPE + OBJECTS {name} + STATUS current + DESCRIPTION + "Trap caused by user test" + ::= {traps 52} + + + + + +trap-digout-inactive1 NOTIFICATION-TYPE + OBJECTS {name} + STATUS current + DESCRIPTION + "Trap caused by digitout output #1 going inactive" + ::= {traps 72} + +trap-digout-inactive2 NOTIFICATION-TYPE + OBJECTS {name} + STATUS current + DESCRIPTION + "Trap caused by digitout output #2 going inactive" + ::= {traps 73} + +trap-digout-inactive3 NOTIFICATION-TYPE + OBJECTS {name} + STATUS current + DESCRIPTION + "Trap caused by digitout output #3 going inactive" + ::= {traps 74} + +trap-digout-inactive4 NOTIFICATION-TYPE + OBJECTS {name} + STATUS current + DESCRIPTION + "Trap caused by digitout output #4 going inactive" + ::= {traps 75} + +trap-digout-inactive5 NOTIFICATION-TYPE + OBJECTS {name} + STATUS current + DESCRIPTION + "Trap caused by digitout output #5 going inactive" + ::= {traps 76} + + + +trap-digout-active1 NOTIFICATION-TYPE + OBJECTS {name} + STATUS current + DESCRIPTION + "Trap caused by digitout output #1 going active" + ::= {traps 88} + +trap-digout-active2 NOTIFICATION-TYPE + OBJECTS {name} + STATUS current + DESCRIPTION + "Trap caused by digitout output #2 going active" + ::= {traps 89} + +trap-digout-active3 NOTIFICATION-TYPE + OBJECTS {name} + STATUS current + DESCRIPTION + "Trap caused by digitout output #3 going active" + ::= {traps 90} + +trap-digout-active4 NOTIFICATION-TYPE + OBJECTS {name} + STATUS current + DESCRIPTION + "Trap caused by digitout output #4 going active" + ::= {traps 91} + +trap-digout-active5 NOTIFICATION-TYPE + OBJECTS {name} + STATUS current + DESCRIPTION + "Trap caused by digitout output #5 going active" + ::= {traps 92} + + + + + + +trap-analog-urecover6 NOTIFICATION-TYPE + OBJECTS {name, analog6val} + STATUS current + DESCRIPTION + "Trap caused by analog input #6 recovering from under alarm" + ::= {traps 109} + + +trap-analog-orecover1 NOTIFICATION-TYPE + OBJECTS {name, analog1val} + STATUS current + DESCRIPTION + "Trap caused by analog input #1 recovering from over alarm" + ::= {traps 120} + +trap-analog-orecover2 NOTIFICATION-TYPE + OBJECTS {name, analog2val} + STATUS current + DESCRIPTION + "Trap caused by analog input #2 recovering from over alarm" + ::= {traps 121} + +trap-analog-orecover3 NOTIFICATION-TYPE + OBJECTS {name, analog3val} + STATUS current + DESCRIPTION + "Trap caused by analog input #3 recovering from over alarm" + ::= {traps 122} + +trap-analog-orecover4 NOTIFICATION-TYPE + OBJECTS {name, analog4val} + STATUS current + DESCRIPTION + "Trap caused by analog input #4 recovering from over alarm" + ::= {traps 123} + +trap-analog-orecover5 NOTIFICATION-TYPE + OBJECTS {name, analog5val} + STATUS current + DESCRIPTION + "Trap caused by analog input #5 recovering from over alarm" + ::= {traps 124} + +trap-analog-orecover6 NOTIFICATION-TYPE + OBJECTS {name, analog6val} + STATUS current + DESCRIPTION + "Trap caused by analog input #6 recovering from over alarm" + ::= {traps 125} + + + + + + +END |