summaryrefslogtreecommitdiff
path: root/MIBS/saf/SAF-INTEGRAE-MIB
diff options
context:
space:
mode:
Diffstat (limited to 'MIBS/saf/SAF-INTEGRAE-MIB')
-rw-r--r--MIBS/saf/SAF-INTEGRAE-MIB2187
1 files changed, 2187 insertions, 0 deletions
diff --git a/MIBS/saf/SAF-INTEGRAE-MIB b/MIBS/saf/SAF-INTEGRAE-MIB
new file mode 100644
index 0000000..0497694
--- /dev/null
+++ b/MIBS/saf/SAF-INTEGRAE-MIB
@@ -0,0 +1,2187 @@
+SAF-INTEGRAE-MIB DEFINITIONS ::= BEGIN
+
+-- Definitions for include by other SAF Tehnika mib modules
+
+IMPORTS
+ MODULE-IDENTITY, OBJECT-TYPE, Integer32, Gauge32, Counter64,
+ TimeTicks
+ FROM SNMPv2-SMI -- [RFC2578]
+ pointToPoint
+ FROM SAF-ENTERPRISE
+ DateAndTime, TEXTUAL-CONVENTION
+ FROM SNMPv2-TC
+ DisplayString, PhysAddress
+ FROM RFC1213-MIB
+ safIntegra
+ FROM SAF-INTEGRA-MIB
+ OBJECT-GROUP, MODULE-COMPLIANCE
+ FROM SNMPv2-CONF -- [RFC2580]
+ IpAddress
+ FROM SNMPv2-SMI -- [RFC2578]
+ IANAifType
+ FROM IANAifType-MIB;
+
+-- saf OBJECT IDENTIFIER ::= { enterprises 7571 }
+-- microwaveRadio OBJECT IDENTIFIER ::= { tehnika 1 }
+-- pointToPoint OBJECT IDENTIFIER ::= { microwaveRadio 1 }
+-- safIntegra OBJECT IDENTIFIER ::= { pointToPoint 7 }
+
+integraE MODULE-IDENTITY
+ LAST-UPDATED "202004250000Z" -- 25 apr 2020
+ ORGANIZATION "SAF Tehnika"
+ CONTACT-INFO
+ "SAF Tehnika technical support
+ <techsupport@saftehnika.com>"
+ DESCRIPTION
+ "SAF Integra-E device management base"
+-- Revision history
+ REVISION "202004250000Z" -- 25 apr 2020
+ DESCRIPTION
+ "ACMB min/max modem modulation read-only support"
+ REVISION "202004220000Z" -- 22 apr 2020
+ DESCRIPTION
+ "ATPC read-only support"
+ REVISION "202001140000Z" -- 14 jan 2020
+ DESCRIPTION
+ "Added LSP/Backup port status."
+ REVISION "201911210000Z" -- 21 nov 2019
+ DESCRIPTION
+ "Added system service sensors."
+ REVISION "201906110000Z" -- 11 jun 2019
+ DESCRIPTION
+ "Added device fan error status."
+ REVISION "201904230000Z" -- 23 apr 2019
+ DESCRIPTION
+ "Added device type, serial number and product code."
+ REVISION "201903120000Z" -- 12 mar 2019
+ DESCRIPTION
+ "Changed integraEifPortSpeed to integraEifPortHighSpeed, that will use Mbps instead of bps."
+ REVISION "201902040000Z" -- 04 feb 2019
+ DESCRIPTION
+ "FEC load parameter type changed to Integer32"
+ REVISION "201811150000Z" -- 15 nov 2018
+ DESCRIPTION
+ "FEC locked modem parameter added"
+ REVISION "201811140000Z" -- 14 nov 2018
+ DESCRIPTION
+ "Public Release 1.0"
+ ::= { safIntegra 9 }
+
+
+
+FixedDiv20 ::= TEXTUAL-CONVENTION
+ DISPLAY-HINT "d-2"
+ STATUS current
+ DESCRIPTION "Fixed point, two decimals"
+ SYNTAX Integer32
+
+FixedDiv10 ::= TEXTUAL-CONVENTION
+ DISPLAY-HINT "d-1"
+ STATUS current
+ DESCRIPTION "Fixed point, two decimals"
+ SYNTAX Integer32
+
+
+
+integraEtimestamp OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Last data update time"
+ ::= { integraE 1 }
+
+integraEradio OBJECT IDENTIFIER ::= { integraE 2 }
+
+integraEradioTxPower OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "dBm"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Output power of radio transmitter"
+ ::= { integraEradio 1 }
+
+integraEradioTxFrequency OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "kHz"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Frequency of radio transmitter"
+ ::= { integraEradio 2 }
+
+integraEradioRxLevel OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "dBm"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Level of the received signal"
+ ::= { integraEradio 3 }
+
+integraEradioSide OBJECT-TYPE
+ SYNTAX INTEGER {
+ high(1),
+ low(2),
+ error(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Radio side: Low/High"
+ ::= { integraEradio 4 }
+
+integraEradioTxMute OBJECT-TYPE
+ SYNTAX INTEGER {
+ on(1),
+ off(2),
+ error(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Status of 'Tx mute'
+ 1 - Tx is muted,
+ 2 - Tx is not muted.
+ 3 - Status information unavailable"
+ ::= { integraEradio 5 }
+
+integraEradioDuplexShift OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "kHz"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Utilized duplex shift in kHz"
+ ::= { integraEradio 6 }
+
+integraEradioRxFrequency OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "kHz"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Frequency of radio receiver"
+ ::= { integraEradio 7 }
+
+integraEradioTemperature OBJECT-TYPE
+ SYNTAX FixedDiv10
+ UNITS "C"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Radio module temperature"
+ ::= { integraEradio 8 }
+
+integraEradioTxMuteDuration OBJECT-TYPE
+ SYNTAX Integer32(0..214748364)
+ UNITS "s"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time remaning for Tx to be muted in seconds.
+ To turn mute on send number of seconds between 10 and MAX.
+ To turn mute off send 0.
+ GET will retrieve remaining duration for mute or
+ 0 if Tx mute is turned off."
+ ::= { integraEradio 9 }
+
+--Settable radio parameter range values
+
+integraEradioRangesTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IntegraEradioRangeEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Network interface port status data."
+ ::= { integraEradio 10 }
+
+integraEradioRangeEntry OBJECT-TYPE
+ SYNTAX IntegraEradioRangeEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing network physical port status info."
+ INDEX { integraEradioRangeEntryIndex }
+ ::= { integraEradioRangesTable 1 }
+
+IntegraEradioRangeEntry ::=
+ SEQUENCE {
+ integraEradioRangeEntryIndex
+ Integer32,
+ integraEradioRangeDescr
+ DisplayString,
+ integraEradioRangeTxPower
+ Integer32,
+ integraEradioRangeTxFrequency
+ Integer32
+ }
+
+integraEradioRangeEntryIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..2)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A unique value, greater than zero, for each range
+ entry. Starts with 1 and is equal to a number of all range
+ parameters."
+ ::= { integraEradioRangeEntry 1 }
+
+integraEradioRangeDescr OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..255))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "'Minimal' and 'maximal' labels"
+ ::= { integraEradioRangeEntry 2 }
+
+integraEradioRangeTxPower OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "dBm"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Output power ranges for radio transmitter"
+ ::= { integraEradioRangeEntry 3 }
+
+integraEradioRangeTxFrequency OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "kHz"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Frequency ranges for radio transmitter"
+ ::= { integraEradioRangeEntry 4 }
+
+integraEradioPLL OBJECT-TYPE
+ SYNTAX INTEGER {
+ error(1),
+ ok(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "PLL state of local-oscillator generator"
+ ::= { integraEradio 11 }
+
+integraEradioRxLevelState OBJECT-TYPE
+ SYNTAX INTEGER {
+ ok(1),
+ low(2),
+ high(3),
+ error(4)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Received signal level state"
+ ::= { integraEradio 12 }
+
+integraEradioAtpcState OBJECT-TYPE
+ SYNTAX INTEGER {
+ off(1),
+ on(2),
+ unknown(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "ATPC state"
+ ::= { integraEradio 13 }
+
+integraEradioAtpcUpdatePeriod OBJECT-TYPE
+ SYNTAX Integer32(0..214748364)
+ UNITS "s"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "ATPC update period"
+ ::= { integraEradio 14 }
+
+integraEradioAtpcRxLevelMin OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "dBm"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "ATPC Minimal level of the received signal"
+ ::= { integraEradio 15 }
+
+integraEradioAtpcRxLevelMax OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "dBm"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "ATPC Maximal level of the received signal"
+ ::= { integraEradio 16 }
+
+
+integraEmodem OBJECT IDENTIFIER ::= { integraE 3 }
+
+integraEmodemAcquireStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ acquireInProgress(1),
+ acquireLocked(2),
+ acquireFailed(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "This is the current status of modem data acquire
+ when queried modem status.
+ For detailed info use modemAcquireLastStatusDetails."
+ ::= { integraEmodem 1 }
+
+integraEmodemNormalizedMse OBJECT-TYPE
+ SYNTAX FixedDiv10
+ UNITS "dB"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Current normalized MSE value"
+ ::= { integraEmodem 2 }
+
+-- ldpcDecoderStress OBJECT-TYPE
+integraEmodemFECload OBJECT-TYPE
+ SYNTAX FixedDiv10
+ UNITS "dB"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Decoder stress or FEC load value"
+ ::= { integraEmodem 3 }
+
+integraEmodemFEClocked OBJECT-TYPE
+ SYNTAX INTEGER {
+ no(1),
+ yes(2),
+ unknown(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "FEC locked status"
+ ::= { integraEmodem 4 }
+
+integraEmodemAcquireLastStatusDetails OBJECT-TYPE
+ SYNTAX INTEGER {
+ acquireLocked(1),
+ acquireSweep(4),
+ acquireMSEerror(5),
+ acquireBITerror(6),
+ acquireStopped(12),
+ acquireSMerror(13)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "This is the last status of successfull or unsuccessful modem data acquire"
+ ::= { integraEmodem 5 }
+
+integraEmodemTemperature OBJECT-TYPE
+ SYNTAX FixedDiv10
+ UNITS "C"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Modem DSP temperature"
+ ::= { integraEmodem 6 }
+
+integraEmodemBandwidth OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "kHz"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Signal bandwidth"
+ ::= { integraEmodem 7 }
+
+integraEmodemModulation OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Modulation (preferred)"
+ ::= { integraEmodem 8 }
+
+integraEmodemRxModulation OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Current (actual) Rx Modulation"
+ ::= { integraEmodem 9 }
+
+integraEmodemTxModulation OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Current (actual) Tx Modulation"
+ ::= { integraEmodem 10 }
+
+integraEmodemRxCapacity OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "kb/s"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Rx ethernet capacity in kilobits per second"
+ ::= { integraEmodem 11 }
+
+integraEmodemTxCapacity OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "kb/s"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Tx ethernet capacity in kilobits per second"
+ ::= { integraEmodem 12 }
+
+integraEmodemACMBengine OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled(1),
+ disabled(2),
+ error(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "ACMB engine status"
+ ::= { integraEmodem 13 }
+
+integraEmodemCarrierOffset OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "Hz"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Modem carrier offset"
+ ::= { integraEmodem 14 }
+
+integraEmodemCountTime OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "s"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Modem performance count time"
+ ::= { integraEmodem 15 }
+
+integraEmodemErroredBlock OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Modem performance errored blocks"
+ ::= { integraEmodem 16 }
+
+integraEmodemErroredSecond OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "s"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Modem performance errored seconds"
+ ::= { integraEmodem 17 }
+
+integraEmodemSeverelyErroredSecond OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "s"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Modem performance severely errored seconds"
+ ::= { integraEmodem 18 }
+
+integraEmodemBackgroundBlockError OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Modem performance background block errors"
+ ::= { integraEmodem 19 }
+
+integraEmodemTotalBlockNumber OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Modem performance total block number"
+ ::= { integraEmodem 20 }
+
+integraEmodemErroredSecondRatio OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Modem performance errored second ratio"
+ ::= { integraEmodem 21 }
+
+integraEmodemSeverelyErroredSecondRatio OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Modem performance severely errored second ratio"
+ ::= { integraEmodem 22 }
+
+integraEmodemBackgroundBlockErrorRatio OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Modem performance background block error ratio"
+ ::= { integraEmodem 23 }
+
+integraEmodemUptime OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "s"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Modem performance : uptime"
+ ::= { integraEmodem 24 }
+
+integraEmodemUnavailtime OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "s"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Modem performance : unavailtime"
+ ::= { integraEmodem 25 }
+
+integraEmodemModulationACMBmin OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Minimal modulation for ACMB enabled profile"
+ ::= { integraEmodem 26 }
+
+integraEmodemModulationACMBmax OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Maximal modulation for ACMB enabled profile"
+ ::= { integraEmodem 27 }
+
+
+integraEsystem OBJECT IDENTIFIER ::= { integraE 4 }
+
+integraEsysCPUtemperature OBJECT-TYPE
+ SYNTAX FixedDiv10
+ UNITS "C"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "System CPU temperature"
+ ::= { integraEsystem 2 }
+
+integraEsysLicenseExpire OBJECT-TYPE
+ SYNTAX Gauge32
+ UNITS "s"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "License expires after number of seconds.
+ In the case of -1, check licenseGenStatus status"
+ ::= { integraEsystem 3 }
+integraEsysLicenseGenStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ ok(1),
+ expired(2),
+ unknown(3),
+ unlimitedTime(4)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "License General status."
+ ::= { integraEsystem 4 }
+
+integraEsysPSUvoltage OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "mV"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Power voltage in mV"
+ ::= { integraEsystem 5 }
+
+integraEsysPSUcurrent OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "mA"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Power current in mA"
+ ::= { integraEsystem 6 }
+integraEsysPSUpower OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "mW"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Power consumption in mW"
+ ::= { integraEsystem 7 }
+integraEsysBoardTemperature OBJECT-TYPE
+ SYNTAX FixedDiv10
+ UNITS "C"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "System temperature"
+ ::= { integraEsystem 8 }
+integraEsysFreeMemory OBJECT-TYPE
+ SYNTAX FixedDiv10
+ UNITS "%"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "System free memory"
+ ::= { integraEsystem 9 }
+integraEsysCPUidle OBJECT-TYPE
+ SYNTAX FixedDiv10
+ UNITS "%"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "System CPU idle"
+ ::= { integraEsystem 10 }
+
+integraEsysDeviceType OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Device type name"
+ ::= { integraEsystem 11 }
+
+integraEsysDeviceSerial OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Device serial number"
+ ::= { integraEsystem 12 }
+
+integraEsysDeviceProductModel OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Device product model code"
+ ::= { integraEsystem 13 }
+
+integraEsysFanError OBJECT-TYPE
+ SYNTAX BITS {
+ no(0),
+ fan1(1),
+ unknown(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Device fan 1 error status"
+ ::= { integraEsystem 14 }
+
+-- service sensors
+integraEsysXADCtemperature OBJECT-TYPE
+ SYNTAX FixedDiv10
+ UNITS "C"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "XADC Temperature"
+ ::= { integraEsystem 15 }
+
+integraEsysVCCint OBJECT-TYPE
+ SYNTAX FixedDiv20
+ UNITS "V"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Vcc INT"
+ ::= { integraEsystem 16 }
+
+integraEsysVCCaux OBJECT-TYPE
+ SYNTAX FixedDiv20
+ UNITS "V"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Vcc AUX"
+ ::= { integraEsystem 17 }
+
+integraEsysVCCbram OBJECT-TYPE
+ SYNTAX FixedDiv20
+ UNITS "V"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Vcc BRAM"
+ ::= { integraEsystem 18 }
+
+integraEsysVCCpint OBJECT-TYPE
+ SYNTAX FixedDiv20
+ UNITS "V"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Vcc PINT"
+ ::= { integraEsystem 19 }
+
+integraEsysVCCpaux OBJECT-TYPE
+ SYNTAX FixedDiv20
+ UNITS "V"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Vcc PAUX"
+ ::= { integraEsystem 20 }
+
+integraEsysVCCoddr OBJECT-TYPE
+ SYNTAX FixedDiv20
+ UNITS "V"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Vcc ODDR"
+ ::= { integraEsystem 21 }
+
+integraEsysXadc6v0AvddMdmAna OBJECT-TYPE
+ SYNTAX FixedDiv20
+ UNITS "V"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "XADC_6V0_AVDD_M - Modem Analog"
+ ::= { integraEsystem 22 }
+
+integraEsysXadc1v0AvddSwAna OBJECT-TYPE
+ SYNTAX FixedDiv20
+ UNITS "V"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "XADC_1V0_AVDD_S - Switch Analog"
+ ::= { integraEsystem 23 }
+
+integraEsysXadc1v0AvddMdmAna OBJECT-TYPE
+ SYNTAX FixedDiv20
+ UNITS "V"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "XADC_1V0_AVDD_M - Modem Analog"
+ ::= { integraEsystem 24 }
+
+integraEsysXadc1v0DvddMdmDig OBJECT-TYPE
+ SYNTAX FixedDiv20
+ UNITS "V"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "XADC_1V0_DVDD_M - Modem Digital"
+ ::= { integraEsystem 25 }
+
+integraEsysXadc1v0CoreMdmDig OBJECT-TYPE
+ SYNTAX FixedDiv20
+ UNITS "V"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "XADC_1V0_CORE_M - Modem Digital"
+ ::= { integraEsystem 26 }
+
+integraEsysXadc2v5EnvAdcAvddMdmAna OBJECT-TYPE
+ SYNTAX FixedDiv20
+ UNITS "V"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "XADC_2V5_ENVADC_AVDD - Modem Analog"
+ ::= { integraEsystem 27 }
+
+integraEsysXadc1v0CoreSwDig OBJECT-TYPE
+ SYNTAX FixedDiv20
+ UNITS "V"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "XADC_1V0_CORE_S - Switch Digital"
+ ::= { integraEsystem 28 }
+
+integraEsysXadc5v0IqAvddMdmAna OBJECT-TYPE
+ SYNTAX FixedDiv20
+ UNITS "V"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "XADC_5V0_IQ_AVDD - Modem Analog"
+ ::= { integraEsystem 29 }
+
+integraEsysXadc2v5WbDacClAvddMdmAna OBJECT-TYPE
+ SYNTAX FixedDiv20
+ UNITS "V"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "XADC_2V5_WBDAC_CL_AVDD - Modem Analog"
+ ::= { integraEsystem 30 }
+
+integraEsysXadc1v2VccPhyDig OBJECT-TYPE
+ SYNTAX FixedDiv20
+ UNITS "V"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "XADC_1V2_VCC - PHY Digital"
+ ::= { integraEsystem 31 }
+
+integraEsysXadc4v6AfeDacAvddMdmAna OBJECT-TYPE
+ SYNTAX FixedDiv20
+ UNITS "V"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "XADC_4V6_AFE_DAC_AVDD - Modem Analog"
+ ::= { integraEsystem 32 }
+
+integraEsysXadc2v5WbDacAvddMdmAna OBJECT-TYPE
+ SYNTAX FixedDiv20
+ UNITS "V"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "XADC_2V5_WBDAC_AVDD - Modem Analog"
+ ::= { integraEsystem 33 }
+
+integraEsysXadc2v5VccSysDig OBJECT-TYPE
+ SYNTAX FixedDiv20
+ UNITS "V"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "XADC_2V5_VCC - System Digital"
+ ::= { integraEsystem 34 }
+
+integraEsysXadc3v3VccSysDig OBJECT-TYPE
+ SYNTAX FixedDiv20
+ UNITS "V"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "XADC_3V3_VCC - System Digital"
+ ::= { integraEsystem 35 }
+
+integraEsysXadc1v5Ddr3Sw OBJECT-TYPE
+ SYNTAX FixedDiv20
+ UNITS "V"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "XADC_1V5_DDR3_S - Switch DDR3"
+ ::= { integraEsystem 36 }
+
+integraEsysXadc2v5WbAdcAvddMdmAna OBJECT-TYPE
+ SYNTAX FixedDiv20
+ UNITS "V"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "XADC_2V5_WBADC_AVDD - Modem Analog"
+ ::= { integraEsystem 37 }
+
+integraEsysXadc2v5WbDacPllAvddMdmAna OBJECT-TYPE
+ SYNTAX FixedDiv20
+ UNITS "V"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "XADC_2V5_WBDAC_PLL_AVDD - Modem Analog"
+ ::= { integraEsystem 38 }
+
+-- Ethernet
+integraEethernet OBJECT IDENTIFIER ::= { integraE 5 }
+ -- Port status
+integraEifStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IntegraEifPortEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Network interface port status data."
+ ::= { integraEethernet 1 }
+
+integraEifPortEntry OBJECT-TYPE
+ SYNTAX IntegraEifPortEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing network physical port status info."
+ INDEX { integraEifPortStatIndex }
+ ::= { integraEifStatusTable 1 }
+
+IntegraEifPortEntry ::=
+ SEQUENCE {
+ integraEifPortStatIndex
+ Integer32,
+ integraEifPortStatDescr
+ DisplayString,
+ integraEifPortType
+ IANAifType,
+ integraEifPortMtu
+ Integer32,
+ integraEifPortHighSpeed
+ Gauge32,
+ integraEifPortPhysAddress
+ PhysAddress,
+ integraEifPortAdminStatus
+ INTEGER,
+ integraEifPortOperStatus
+ INTEGER,
+ integraEifPortLastChange
+ TimeTicks,
+ integraEifPortAutoneg
+ INTEGER,
+ integraEifPortDuplex
+ INTEGER,
+ integraEifPortSyncEthActive
+ INTEGER,
+ integraEifPortSyncEthPrio
+ Integer32,
+ integraEifPortFlowControl
+ INTEGER
+ }
+
+integraEifPortStatIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..4)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A unique value, greater than zero, for each physical
+ network interface. It is recommended that
+ values are assigned contiguously starting from 1."
+ ::= { integraEifPortEntry 1 }
+
+integraEifPortStatDescr OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..255))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Physical network interface description.
+ LAN1 is electrical, LAN2 and LAN3 are SFP
+ and WAN is radio port."
+ ::= { integraEifPortEntry 2 }
+
+integraEifPortType OBJECT-TYPE
+ SYNTAX IANAifType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The type of interface, distinguished according to
+ the physical/link protocol(s) immediately `below'
+ the network layer in the protocol stack."
+ ::= { integraEifPortEntry 3 }
+
+integraEifPortMtu OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "B"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Maximum transmission unit value in bytes."
+ ::= { integraEifPortEntry 4 }
+
+integraEifPortHighSpeed OBJECT-TYPE
+ SYNTAX Gauge32
+ UNITS "Mbps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Link speed in 1 000 000 * bits per second."
+ ::= { integraEifPortEntry 5 }
+
+integraEifPortPhysAddress OBJECT-TYPE
+ SYNTAX PhysAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The interface's address at the protocol layer
+ immediately `below' the network layer in the
+ protocol stack. For interfaces which do not have
+ such an address (e.g., a serial line), this object
+ should contain an octet string of zero length."
+ ::= { integraEifPortEntry 6 }
+
+integraEifPortAdminStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled(1),
+ disabled(2),
+ unknown(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Desired state of network interfaces. Interfaces
+ can be enabled(1), disabled(2), unknown(3) (no info received)."
+ ::= { integraEifPortEntry 7 }
+
+integraEifPortOperStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ up(1),
+ down(2),
+ unknown(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Actual state of interfaces. Link can be up(1),
+ down(2) or in unknown(3) state."
+ ::= { integraEifPortEntry 8 }
+
+integraEifPortLastChange OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This parameter value is always 0 at the moment."
+ ::= { integraEifPortEntry 9 }
+
+integraEifPortAutoneg OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled(1),
+ disabled(2),
+ unknown(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Auto-negotiation status. Unknown means no info was received."
+ ::= { integraEifPortEntry 10 }
+
+integraEifPortDuplex OBJECT-TYPE
+ SYNTAX INTEGER {
+ full(1),
+ half(2),
+ unknown(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Duplex status for the interface."
+ ::= { integraEifPortEntry 11 }
+
+integraEifPortSyncEthActive OBJECT-TYPE
+ SYNTAX INTEGER {
+ off(0),
+ on(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Synchronous Ethernet status.
+ Can be active(1) or inactive(0)."
+ ::= { integraEifPortEntry 12 }
+
+integraEifPortSyncEthPrio OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Synchronous Ethernet priority."
+ ::= { integraEifPortEntry 13 }
+
+integraEifPortFlowControl OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled(1),
+ disabled(2),
+ unknown(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Flow control status."
+ ::= { integraEifPortEntry 14 }
+
+
+ -- Port statistics
+integraEifStatisticsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IntegraEifPortStcEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Network interface port statistics data."
+ ::= { integraEethernet 2 }
+
+integraEifPortStcEntry OBJECT-TYPE
+ SYNTAX IntegraEifPortStcEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing network physical port statistics counter data."
+ INDEX { integraEifPortStcIndex }
+ ::= { integraEifStatisticsTable 1 }
+
+IntegraEifPortStcEntry ::=
+ SEQUENCE {
+ integraEifPortStcIndex
+ Integer32,
+ integraEifPortStcDescr
+ DisplayString,
+ integraEifTimePassed
+ TimeTicks,
+ integraEifIngressPackets
+ Counter64,
+ integraEifIngressBytes
+ Counter64,
+ integraEifEgressPackets
+ Counter64,
+ integraEifEgressBytes
+ Counter64,
+ integraEifEtherStatsMulticastPkts
+ Counter64,
+ integraEifEtherStatsBroadcastPkts
+ Counter64,
+ integraEifEtherStatsPkts64Octets
+ Counter64,
+ integraEifEtherStatsPkts65to127Octets
+ Counter64,
+ integraEifEtherStatsPkts128to255Octets
+ Counter64,
+ integraEifEtherStatsPkts256to511Octets
+ Counter64,
+ integraEifEtherStatsPkts512to1023Octets
+ Counter64,
+ integraEifEtherStatsPkts1024to1518Octets
+ Counter64,
+ integraEifEtherStatsOversizePkts
+ Counter64,
+ integraEifEtherRxOversizePkts
+ Counter64,
+ integraEifEtherTxOversizePkts
+ Counter64,
+ integraEifEtherStatsOctets
+ Counter64,
+ integraEifEtherStatsPkts
+ Counter64,
+ integraEifEtherStatsTXNoErrors
+ Counter64,
+ integraEifEtherStatsRXNoErrors
+ Counter64,
+ integraEifEtherStatsPkts1519to1522Octets
+ Counter64,
+ integraEifIfInOctets
+ Counter64,
+ integraEifIfOutOctets
+ Counter64,
+ integraEifDot1dTpPortInFrames
+ Counter64,
+ integraEifDot1dTpPortOutFrames
+ Counter64,
+ integraEifReceivedPkts64Octets
+ Counter64,
+ integraEifTransmittedPkts64Octets
+ Counter64,
+ integraEifReceivedPkts65to127Octets
+ Counter64,
+ integraEifTransmittedPkts65to127Octets
+ Counter64,
+ integraEifReceivedPkts128to255Octets
+ Counter64,
+ integraEifTransmittedPkts128to255Octets
+ Counter64,
+ integraEifReceivedPkts256to511Octets
+ Counter64,
+ integraEifTransmittedPkts256to511Octets
+ Counter64,
+ integraEifReceivedPkts512to1023Octets
+ Counter64,
+ integraEifTransmittedPkts512to1023Octets
+ Counter64,
+ integraEifReceivedPkts1024to1518Octets
+ Counter64,
+ integraEifTransmittedPkts1024to1518Octets
+ Counter64,
+ integraEifIfInBroadcastPkts
+ Counter64,
+ integraEifIfOutBroadcastPkts
+ Counter64,
+ integraEifIfInMulticastPkts
+ Counter64,
+ integraEifIfOutMulticastPkts
+ Counter64,
+ integraEifDot3InPauseFrames
+ Counter64,
+ integraEifDot3OutPauseFrames
+ Counter64,
+ integraEifEtherStatsUndersizePkts
+ Counter64,
+ integraEifEtherStatsFragments
+ Counter64,
+ integraEifEtherStatsCRCAlignErrors
+ Counter64,
+ integraEifEtherStatsJabbers
+ Counter64,
+ integraEifIngressBPS
+ Integer32,
+ integraEifIngressPPS
+ Integer32,
+ integraEifEgressBPS
+ Integer32,
+ integraEifEgressPPS
+ Integer32,
+ integraEifAllCoSQoutPackets
+ Counter64,
+ integraEifAllCoSQoutBytes
+ Counter64,
+ integraEifAllCoSQdroppedPackets
+ Counter64,
+ integraEifAllCoSQdroppedBytes
+ Counter64,
+ integraEifProcessedRxPackets
+ Counter64,
+ integraEifProcessedRxBytes
+ Counter64
+ }
+
+integraEifPortStcIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..5)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A unique value, greater than zero, for each physical
+ network interface. It is recommended that
+ values are assigned contiguously starting from 1."
+ ::= { integraEifPortStcEntry 1 }
+
+integraEifPortStcDescr OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..255))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Physical network interface description.
+ LAN1 is electrical, LAN2 and LAN3 are SFP,
+ WAN is radio port and MNG is internal management interface."
+ ::= { integraEifPortStcEntry 2 }
+
+integraEifTimePassed OBJECT-TYPE
+ SYNTAX TimeTicks
+ UNITS "s/100"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Statistics collection time."
+ ::= { integraEifPortStcEntry 3 }
+
+integraEifIngressPackets OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Packets that ingress on the port."
+ ::= { integraEifPortStcEntry 4 }
+
+integraEifIngressBytes OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "B"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Bytes that ingress on the port."
+ ::= { integraEifPortStcEntry 5 }
+
+integraEifEgressPackets OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Packets that egress on the port."
+ ::= { integraEifPortStcEntry 6 }
+
+integraEifEgressBytes OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "B"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Bytes that egress on the port."
+ ::= { integraEifPortStcEntry 7 }
+
+integraEifEtherStatsMulticastPkts OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of good packets (both received and
+ transmitted) that were directed to a multicast address.
+ Note that this number does not include packets directed
+ to the broadcast address."
+ ::= { integraEifPortStcEntry 8 }
+
+integraEifEtherStatsBroadcastPkts OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of good packets (both received and
+ transmitted) that were directed to the broadcast address.
+ Note that this does not include multicast packets."
+ ::= { integraEifPortStcEntry 9 }
+
+integraEifEtherStatsPkts64Octets OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of packets (including bad
+ packets) (both received and transmitted)
+ that were 64 octets in length
+ (excluding framing bits but including FCS octets)."
+ ::= { integraEifPortStcEntry 10 }
+
+integraEifEtherStatsPkts65to127Octets OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of packets (including bad
+ packets) (both received and transmitted)
+ that were between 65 and 127 octets in length inclusive
+ (excluding framing bits but including FCS octets)."
+ ::= { integraEifPortStcEntry 11 }
+
+integraEifEtherStatsPkts128to255Octets OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of packets (including bad
+ packets) (both received and transmitted) that were
+ between 128 and 255 octets in length inclusive
+ (excluding framing bits but including FCS octets)."
+ ::= { integraEifPortStcEntry 12 }
+
+integraEifEtherStatsPkts256to511Octets OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of packets (including bad
+ packets) (both received and transmitted) that were
+ between 256 and 511 octets in length inclusive
+ (excluding framing bits but including FCS octets)."
+ ::= { integraEifPortStcEntry 13 }
+
+integraEifEtherStatsPkts512to1023Octets OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of packets (including bad
+ packets) (both received and transmitted) that were
+ between 512 and 1023 octets in length inclusive
+ (excluding framing bits but including FCS octets)."
+ ::= { integraEifPortStcEntry 14 }
+
+integraEifEtherStatsPkts1024to1518Octets OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of packets (including bad
+ packets) (both received and transmitted) that were
+ between 1024 and 1518 octets in length inclusive
+ (excluding framing bits but including FCS octets)."
+ ::= { integraEifPortStcEntry 15 }
+
+integraEifEtherStatsOversizePkts OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of packets (both received and
+ transmitted) that were longer than 1518
+ octets (excluding framing bits but including
+ FCS octets) but were otherwise well formed."
+ ::= { integraEifPortStcEntry 16 }
+
+integraEifEtherRxOversizePkts OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of packets received
+ that were longer than 1518 octets
+ (excluding framing bits but including
+ FCS octets) but were otherwise well formed."
+ ::= { integraEifPortStcEntry 17 }
+
+integraEifEtherTxOversizePkts OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of packets transmitted
+ that were longer than 1518 octets
+ (excluding framing bits but including
+ FCS octets) but were otherwise well formed."
+ ::= { integraEifPortStcEntry 18 }
+
+integraEifEtherStatsOctets OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of octets of data (including
+ those in bad packets) both received and
+ transmitted."
+ ::= { integraEifPortStcEntry 19 }
+
+integraEifEtherStatsPkts OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of packets (including bad packets)
+ both received and transmitted."
+ ::= { integraEifPortStcEntry 20 }
+
+integraEifEtherStatsTXNoErrors OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of packets that were transmitted
+ without errors."
+ ::= { integraEifPortStcEntry 21 }
+
+integraEifEtherStatsRXNoErrors OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of packets that were received
+ without errors."
+ ::= { integraEifPortStcEntry 22 }
+
+integraEifEtherStatsPkts1519to1522Octets OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of packets (including bad
+ packets) (both received and transmitted) that were
+ between 1519 and 1522 octets in length inclusive
+ (excluding framing bits but including FCS octets)."
+ ::= { integraEifPortStcEntry 23 }
+
+integraEifIfInOctets OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "octet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of octets of data (including
+ those in bad packets) that were received."
+ ::= { integraEifPortStcEntry 24 }
+
+integraEifIfOutOctets OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "octet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of octets of data (including
+ those in bad packets) that were transmitted."
+ ::= { integraEifPortStcEntry 25 }
+
+integraEifDot1dTpPortInFrames OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "frame"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of frames that have been received by
+ this port from its segment."
+ ::= { integraEifPortStcEntry 26 }
+
+integraEifDot1dTpPortOutFrames OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "frame"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of frames that have been transmitted by
+ this port to its segment."
+ ::= { integraEifPortStcEntry 27 }
+
+integraEifReceivedPkts64Octets OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of received packets that were
+ 64 octets in length (excluding framing bits
+ but including FCS octets)."
+ ::= { integraEifPortStcEntry 28 }
+
+integraEifTransmittedPkts64Octets OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of transmitted packets that were
+ 64 octets in length (excluding framing bits
+ but including FCS octets)."
+ ::= { integraEifPortStcEntry 29 }
+
+integraEifReceivedPkts65to127Octets OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of received packets that were
+ between 65 and 127 octets in length inclusive
+ (excluding framing bits but including FCS octets)."
+ ::= { integraEifPortStcEntry 30 }
+
+integraEifTransmittedPkts65to127Octets OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of transmitted packets that were
+ between 65 and 127 octets in length inclusive
+ (excluding framing bits but including FCS octets)."
+ ::= { integraEifPortStcEntry 31 }
+
+integraEifReceivedPkts128to255Octets OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of received packets that were
+ between 128 and 255 octets in length inclusive
+ (excluding framing bits but including FCS octets)."
+ ::= { integraEifPortStcEntry 32 }
+
+integraEifTransmittedPkts128to255Octets OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of transmitted packets that were
+ between 128 and 255 octets in length inclusive
+ (excluding framing bits but including FCS octets)."
+ ::= { integraEifPortStcEntry 33 }
+
+integraEifReceivedPkts256to511Octets OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of received packets that were
+ between 256 and 511 octets in length inclusive
+ (excluding framing bits but including FCS octets)."
+ ::= { integraEifPortStcEntry 34 }
+
+integraEifTransmittedPkts256to511Octets OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of transmitted packets that were
+ between 256 and 511 octets in length inclusive
+ (excluding framing bits but including FCS octets)."
+ ::= { integraEifPortStcEntry 35 }
+
+integraEifReceivedPkts512to1023Octets OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of received packets that were
+ between 512 and 1023 octets in length inclusive
+ (excluding framing bits but including FCS octets)."
+ ::= { integraEifPortStcEntry 36 }
+
+integraEifTransmittedPkts512to1023Octets OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of transmitted packets that were
+ between 512 and 1023 octets in length inclusive
+ (excluding framing bits but including FCS octets)."
+ ::= { integraEifPortStcEntry 37 }
+
+integraEifReceivedPkts1024to1518Octets OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of received packets that were
+ between 1024 and 1518 octets in length inclusive
+ (excluding framing bits but including FCS octets)."
+ ::= { integraEifPortStcEntry 38 }
+
+integraEifTransmittedPkts1024to1518Octets OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of transmitted packets that were
+ between 1024 and 1518 octets in length inclusive
+ (excluding framing bits but including FCS octets)."
+ ::= { integraEifPortStcEntry 39 }
+
+integraEifIfInBroadcastPkts OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of received good packets
+ that were directed to the broadcast address.
+ Note that this does not include multicast packets."
+ ::= { integraEifPortStcEntry 40 }
+
+integraEifIfOutBroadcastPkts OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of transmitted good packets
+ that were directed to the broadcast address.
+ Note that this does not include multicast packets."
+ ::= { integraEifPortStcEntry 41 }
+
+integraEifIfInMulticastPkts OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of received good packets
+ that were directed to a multicast address.
+ Note that this number does not include broadcast packets."
+ ::= { integraEifPortStcEntry 42 }
+
+integraEifIfOutMulticastPkts OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of transmitted good packets
+ that were directed to a multicast address.
+ Note that this number does not include broadcast packets."
+ ::= { integraEifPortStcEntry 43 }
+
+integraEifDot3InPauseFrames OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "frame"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A count of MAC Control frames received on this
+ interface with an opcode indicating the PAUSE
+ operation.
+ This counter does not increment when the
+ interface is operating in half-duplex mode."
+ ::= { integraEifPortStcEntry 44 }
+
+integraEifDot3OutPauseFrames OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "frame"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A count of MAC Control frames transmitted on
+ this interface with an opcode indicating the
+ PAUSE operation.
+ This counter does not increment when the
+ interface is operating in half-duplex mode."
+ ::= { integraEifPortStcEntry 45 }
+
+integraEifEtherStatsUndersizePkts OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of packets received that were
+ less than 64 octets long (excluding framing bits,
+ but including FCS octets) and were otherwise well
+ formed."
+ ::= { integraEifPortStcEntry 46 }
+
+integraEifEtherStatsFragments OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of packets received that were less than
+ 64 octets in length (excluding framing bits but including
+ FCS octets) and had either a bad Frame Check Sequence
+ (FCS) with an integral number of octets (FCS Error) or a
+ bad FCS with a non-integral number of octets (Alignment
+ Error).
+ Note that it is entirely normal for etherStatsFragments to
+ increment. This is because it counts both runts (which are
+ normal occurrences due to collisions) and noise hits."
+ ::= { integraEifPortStcEntry 47 }
+
+integraEifEtherStatsCRCAlignErrors OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of packets received that
+ had a length (excluding framing bits, but
+ including FCS octets) of between 64 and 1518
+ octets, inclusive, but had either a bad
+ Frame Check Sequence (FCS) with an integral
+ number of octets (FCS Error) or a bad FCS with
+ a non-integral number of octets (Alignment Error)."
+ ::= { integraEifPortStcEntry 48 }
+
+integraEifEtherStatsJabbers OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of packets received that were
+ longer than 1518 octets (excluding framing bits,
+ but including FCS octets), and had either a bad
+ Frame Check Sequence (FCS) with an integral number
+ of octets (FCS Error) or a bad FCS with a non-integral
+ number of octets (Alignment Error).
+ Note that this definition of jabber is different
+ than the definition in IEEE-802.3 section 8.2.1.5
+ (10BASE5) and section 10.3.1.4 (10BASE2). These
+ documents define jabber as the condition where any
+ packet exceeds 20 ms. The allowed range to detect
+ jabber is between 20 ms and 150 ms."
+ ::= { integraEifPortStcEntry 49 }
+
+integraEifIngressBPS OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "Bps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Ingoing data transfer rate in bytes per second."
+ ::= { integraEifPortStcEntry 50 }
+
+integraEifIngressPPS OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "pps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Ingoing data transfer rate in packets per second."
+ ::= { integraEifPortStcEntry 51 }
+
+integraEifEgressBPS OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "Bps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Outgoing data transfer rate in bytes per second."
+ ::= { integraEifPortStcEntry 52 }
+
+integraEifEgressPPS OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "pps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Outgoing data transfer rate in packets per second."
+ ::= { integraEifPortStcEntry 53 }
+
+integraEifAllCoSQoutPackets OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "All CoSQ outgoing packets."
+ ::= { integraEifPortStcEntry 54 }
+
+integraEifAllCoSQoutBytes OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "B"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "All CoSQ outgoing bytes."
+ ::= { integraEifPortStcEntry 55 }
+
+integraEifAllCoSQdroppedPackets OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "All CoSQ dropped packets."
+ ::= { integraEifPortStcEntry 56 }
+
+integraEifAllCoSQdroppedBytes OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "B"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "All CoSQ dropped bytes."
+ ::= { integraEifPortStcEntry 57 }
+
+integraEifProcessedRxPackets OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packet"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Processed received packets."
+ ::= { integraEifPortStcEntry 58 }
+
+integraEifProcessedRxBytes OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "B"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Processed received bytes."
+ ::= { integraEifPortStcEntry 59 }
+
+
+integraEifLspPortAdminState OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(1),
+ lsp(2),
+ backup(3),
+ unknown(4)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "LSP port status."
+ ::= { integraEethernet 3 }
+
+integraEifLspPortList OBJECT-TYPE
+ SYNTAX BITS {
+ none(0),
+ lan1(1),
+ lan2(2),
+ lan3(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "LSP port status."
+ ::= { integraEethernet 4 }
+
+integraEifLspPortStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ lspPortOK(1),
+ lspPortDownBlockedByLSP(2),
+ backupNoLink(3),
+ backupLinkActive(4),
+ backupLinkReady(5),
+ unknown(6)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "LSP port status."
+ ::= { integraEethernet 5 }
+
+-- Configuration applying/saving objects
+
+integraEexecuteConfig OBJECT-TYPE
+ SYNTAX INTEGER {
+ execute(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "This object can only be set to 1.
+ It initiates new running configuration
+ applying using values, that have been set before.
+ Setting it when no new changes are available
+ will do nothing and return an error.
+ GET will return 0 if there were no errors,
+ while executing configuration or will return
+ a bitmask, that shows which SET requests have failed.
+ Those failed requests will be shown bit wise
+ from LSB as follows:
+ BIT0 radioTxMuteDuration
+ BIT1 radioTxFrequency
+ BIT2 radioTxPower"
+ ::= { integraE 6 }
+
+integraEneedStore OBJECT-TYPE
+ SYNTAX INTEGER {
+ no(0)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "This object shows if there is unsaved,
+ but executed (running) configuration.
+ Unsaved changes will be lost after
+ device reboot. Unsaved entities are shown
+ bit wise, starting from LSB as follows:
+ BIT0 Aggregation
+ BIT1 Event log
+ BIT2 Modem
+ BIT3 Network
+ BIT4 Performance
+ BIT5 Radio
+ BIT6 SNMP
+ BIT7 Synchronous Ethernet
+ BIT8 System"
+ ::= { integraE 7 }
+
+integraEstoreConfig OBJECT-TYPE
+ SYNTAX INTEGER {
+ store(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "This object can only be set to 1.
+ It initiates saving of running configuration.
+ It will only work if there are unsaved,
+ but executed (running) changes (configuration).
+ Setting it when no new running configuration
+ is available will do nothing and return an error."
+ ::= { integraE 8 }
+
+
+-- IP settings
+
+integraEnetCfg OBJECT IDENTIFIER ::= { integraE 9 }
+
+integraEnetCfgIPaddress OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Local IP address"
+ ::= { integraEnetCfg 1 }
+
+integraEnetCfgIPmask OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Local IP mask"
+ ::= { integraEnetCfg 2 }
+
+integraEnetCfgIPgateway OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "IP gateway
+ Send '0' or '255.255.255.255' to clear."
+ ::= { integraEnetCfg 3 }
+
+integraEnetCfgRemoteIPaddress OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Remote IP address"
+ ::= { integraEnetCfg 4 }
+
+
+-- Conformance
+
+integraEConformance OBJECT IDENTIFIER ::= { integraE 10 }
+integraECompliances OBJECT IDENTIFIER ::= { integraEConformance 1 }
+
+integraECompliance MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION "The compliance statement for SNMP engine which
+ implements the SAF Tehnika Integra-E device."
+ MODULE -- this module
+ MANDATORY-GROUPS {
+ integraEMiscGroup,
+ integraERadioGroup,
+ integraEModemGroup,
+ integraESystemGroup,
+ integraEEthernetGeneralGroup,
+ integraEEthernetMiiPortGroup }
+ ::= { integraECompliances 1 }
+integraEGroups OBJECT IDENTIFIER ::= { integraEConformance 2 }
+
+integraEMiscGroup OBJECT-GROUP
+ OBJECTS {
+ integraEtimestamp
+ }
+ STATUS current
+ DESCRIPTION "misc data"
+ ::= { integraEGroups 1 }
+
+integraERadioGroup OBJECT-GROUP
+ OBJECTS {
+ integraEradioTxPower,
+ integraEradioTxFrequency,
+ integraEradioRxLevel,
+ integraEradioSide,
+ integraEradioTxMute,
+ integraEradioDuplexShift,
+ integraEradioRxFrequency,
+ integraEradioTemperature,
+ integraEradioTxMuteDuration,
+ integraEradioRangeEntryIndex,
+ integraEradioRangeDescr,
+ integraEradioRangeTxPower,
+ integraEradioRangeTxFrequency,
+ integraEradioPLL,
+ integraEradioRxLevelState,
+ integraEradioAtpcState,
+ integraEradioAtpcUpdatePeriod,
+ integraEradioAtpcRxLevelMin,
+ integraEradioAtpcRxLevelMax
+ }
+ STATUS current
+ DESCRIPTION "Radio group."
+ ::= { integraEGroups 2 }
+
+integraEModemGroup OBJECT-GROUP
+ OBJECTS {
+ integraEmodemAcquireStatus,
+ integraEmodemNormalizedMse,
+ integraEmodemFECload,
+ integraEmodemFEClocked,
+ integraEmodemAcquireLastStatusDetails,
+ integraEmodemTemperature,
+ integraEmodemBandwidth,
+ integraEmodemModulation,
+ integraEmodemRxModulation,
+ integraEmodemTxModulation,
+ integraEmodemRxCapacity,
+ integraEmodemTxCapacity,
+ integraEmodemACMBengine,
+ integraEmodemCarrierOffset,
+ integraEmodemCountTime,
+ integraEmodemErroredBlock,
+ integraEmodemErroredSecond,
+ integraEmodemSeverelyErroredSecond,
+ integraEmodemBackgroundBlockError,
+ integraEmodemTotalBlockNumber,
+ integraEmodemErroredSecondRatio,
+ integraEmodemSeverelyErroredSecondRatio,
+ integraEmodemBackgroundBlockErrorRatio,
+ integraEmodemUptime,
+ integraEmodemUnavailtime,
+ integraEmodemModulationACMBmin,
+ integraEmodemModulationACMBmax
+ }
+ STATUS current
+ DESCRIPTION "Modem group."
+ ::= { integraEGroups 3 }
+
+integraESystemGroup OBJECT-GROUP
+ OBJECTS {
+ integraEsysCPUtemperature,
+ integraEsysLicenseExpire,
+ integraEsysLicenseGenStatus,
+ integraEsysPSUvoltage,
+ integraEsysPSUcurrent,
+ integraEsysPSUpower,
+ integraEsysBoardTemperature,
+ integraEsysFreeMemory,
+ integraEsysCPUidle,
+ integraEsysDeviceType,
+ integraEsysDeviceSerial,
+ integraEsysDeviceProductModel,
+ integraEsysFanError,
+ integraEexecuteConfig,
+ integraEneedStore,
+ integraEstoreConfig,
+ integraEsysXADCtemperature,
+ integraEsysVCCint,
+ integraEsysVCCaux,
+ integraEsysVCCbram,
+ integraEsysVCCpint,
+ integraEsysVCCpaux,
+ integraEsysVCCoddr,
+ integraEsysXadc6v0AvddMdmAna,
+ integraEsysXadc1v0AvddSwAna,
+ integraEsysXadc1v0AvddMdmAna,
+ integraEsysXadc1v0DvddMdmDig,
+ integraEsysXadc1v0CoreMdmDig,
+ integraEsysXadc2v5EnvAdcAvddMdmAna,
+ integraEsysXadc1v0CoreSwDig,
+ integraEsysXadc5v0IqAvddMdmAna,
+ integraEsysXadc2v5WbDacClAvddMdmAna,
+ integraEsysXadc1v2VccPhyDig,
+ integraEsysXadc4v6AfeDacAvddMdmAna,
+ integraEsysXadc2v5WbDacAvddMdmAna,
+ integraEsysXadc2v5VccSysDig,
+ integraEsysXadc3v3VccSysDig,
+ integraEsysXadc1v5Ddr3Sw,
+ integraEsysXadc2v5WbAdcAvddMdmAna,
+ integraEsysXadc2v5WbDacPllAvddMdmAna
+ }
+ STATUS current
+ DESCRIPTION "System group."
+ ::= { integraEGroups 4 }
+
+integraEEthernetGeneralGroup OBJECT-GROUP
+ OBJECTS {
+ integraEifPortStatIndex,
+ integraEifPortStatDescr,
+ integraEifPortType,
+ integraEifPortMtu,
+ integraEifPortHighSpeed,
+ integraEifPortPhysAddress,
+ integraEifPortAdminStatus,
+ integraEifPortOperStatus,
+ integraEifPortLastChange,
+ integraEifPortAutoneg,
+ integraEifPortDuplex,
+ integraEifPortSyncEthActive,
+ integraEifPortSyncEthPrio,
+ integraEifPortFlowControl,
+ integraEifPortStcIndex,
+ integraEifPortStcDescr,
+ integraEifTimePassed,
+ integraEifIngressPackets,
+ integraEifIngressBytes,
+ integraEifEgressPackets,
+ integraEifEgressBytes,
+ integraEifEtherRxOversizePkts,
+ integraEifEtherTxOversizePkts,
+ integraEifReceivedPkts64Octets,
+ integraEifTransmittedPkts64Octets,
+ integraEifReceivedPkts65to127Octets,
+ integraEifTransmittedPkts65to127Octets,
+ integraEifReceivedPkts128to255Octets,
+ integraEifTransmittedPkts128to255Octets,
+ integraEifReceivedPkts256to511Octets,
+ integraEifTransmittedPkts256to511Octets,
+ integraEifReceivedPkts512to1023Octets,
+ integraEifTransmittedPkts512to1023Octets,
+ integraEifReceivedPkts1024to1518Octets,
+ integraEifTransmittedPkts1024to1518Octets,
+ integraEifIfInBroadcastPkts,
+ integraEifIfOutBroadcastPkts,
+ integraEifIfInMulticastPkts,
+ integraEifIfOutMulticastPkts,
+ integraEifIngressBPS,
+ integraEifIngressPPS,
+ integraEifEgressBPS,
+ integraEifEgressPPS,
+ integraEifAllCoSQoutPackets,
+ integraEifAllCoSQoutBytes,
+ integraEifAllCoSQdroppedPackets,
+ integraEifAllCoSQdroppedBytes,
+ integraEifProcessedRxPackets,
+ integraEifProcessedRxBytes,
+ integraEnetCfgIPaddress,
+ integraEnetCfgIPmask,
+ integraEnetCfgIPgateway,
+ integraEnetCfgRemoteIPaddress,
+ integraEifLspPortAdminState,
+ integraEifLspPortList,
+ integraEifLspPortStatus
+ }
+ STATUS current
+ DESCRIPTION "A collection to objects, providing info applicable to
+ all network interfaces."
+ ::= { integraEGroups 5 }
+
+integraEEthernetMiiPortGroup OBJECT-GROUP
+ OBJECTS {
+ integraEifEtherStatsMulticastPkts,
+ integraEifEtherStatsBroadcastPkts,
+ integraEifEtherStatsPkts64Octets,
+ integraEifEtherStatsPkts65to127Octets,
+ integraEifEtherStatsPkts128to255Octets,
+ integraEifEtherStatsPkts256to511Octets,
+ integraEifEtherStatsPkts512to1023Octets,
+ integraEifEtherStatsPkts1024to1518Octets,
+ integraEifEtherStatsOversizePkts,
+ integraEifEtherStatsOctets,
+ integraEifEtherStatsPkts,
+ integraEifEtherStatsTXNoErrors,
+ integraEifEtherStatsRXNoErrors,
+ integraEifEtherStatsPkts1519to1522Octets,
+ integraEifIfInOctets,
+ integraEifIfOutOctets,
+ integraEifDot1dTpPortInFrames,
+ integraEifDot1dTpPortOutFrames,
+ integraEifDot3InPauseFrames,
+ integraEifDot3OutPauseFrames,
+ integraEifEtherStatsUndersizePkts,
+ integraEifEtherStatsFragments,
+ integraEifEtherStatsCRCAlignErrors,
+ integraEifEtherStatsJabbers
+ }
+ STATUS current
+ DESCRIPTION "A collection of objects, providing info applicable
+ only to MII group interfaces."
+ ::= { integraEGroups 6 }
+
+
+END