+-- TRIPP LITE PRODUCTS MIB
+-- Copyright (c) 1999-2018 Tripp Lite
+-- All rights reserved
+--
+-- Revision History:
+-- 03/13/2013 Consolidated for PAL v12.06
+-- 04/14/2014 Consolidated for PAL v15.00
+-- 12/04/2014 Created ATS section
+-- 03/19/2015 Created tlpPduHeatsink and tlpAtsHeatsink
+-- 04/20/2015 Added tlpAtsConfigVoltageRangeTable
+-- 06/08/2015 Added tlpAtsInputBadVoltageThreshold
+-- 08/19/2015 Added tlpAtsConfigThresholdTable
+-- 10/16/2015 Added tlpAtsConfigSource#ReturnTime
+-- 11/10/2015 Refactored tlpUps
+-- 11/25/2015 Refactored UPS, PDU and ATS input sections
+-- 01/08/2016 Added tlpAtsConfigVoltageRangeLimitsTable
+-- 01/20/2016 Added tlpDeviceIdentUptime
+-- 01/25/2016 Redefined tlpUpsAlarmLoadLevelAboveThreshold
+-- 02/02/2016 Reworked tlpAgentAttributes
+-- 03/31/2016 Expanded well known alarms
+-- 06/22/2016 Refactored MIB to extend from tripplite.mib
+-- 07/11/2016 Expanded tlpNotify for non-alarm notifications
+-- 01/17/2017 Changed tlpUpsBatteryDetailCurrent to signed
+-- 04/03/2017 Refactored Cooling section
+-- 04/19/2017 Refactored tlpAtsConfigVoltageRangeTable
+-- 05/23/2017 Added more objects to Cooling section
+-- 07/31/2017 Added tlpPduConfigPhaseThresholdTable,tlpAtsConfigPhaseThresholdTable
+--- and new alarms to support "Output Current Below Threshold" events
+-- 08/30/2017 Updated the description of tlpPduIdentNumBreakers and tlpAtsIdentNumBreakers
+-- 09/28/2017 Added tlpCoolingCompressorStatus
+-- 11/30/2017 Added tlpAtsOutputFrequency and tlpPduOutputFrequency
+-- 01/15/2018 Updated/Corrected some descriptions and typos
+-- 03/19/2018 Added tlpCoolingWaterStatus
+-- 04/25/2018 Obsoleted tlpAgentSnmpContactPrivPassword and tlpAgentSnmpContactAuthPassword
+-- 04/30/2018 Added tlpUpsOutputVARating
+-- 05/08/2018 Updated the description of tlpCoolingFanSpeed
+-- 05/10/2018 Updated the UNIT definition of tlpUpsDeviceTemperatureF, tlpUpsDeviceTemperatureC,
+-- tlpPduInputLowTransferVoltageLowerBound, tlpPduInputLowTransferVoltageUpperBound,
+-- tlpPduInputHighTransferVoltageLowerBound and tlpPduInputHighTransferVoltageUpperBound
+-- 07/17/2018 Added tlpPduOutputCalculatedPowerKVA, tlpPduOutputCalculatedPowerKW tlpPduOutputCalculated24hrEnergy,
+-- tlpAtsOutputCalculatedPowerKVA, tlpAtsOutputCalculatedPowerKW and tlpAtsOutputCalculated24hrEnergy
+-- 01/17/2019 Added tlpDeviceIdentFirmwareVersion2, tlpDeviceIdentFirmwareVersion3, tlpUpsDeviceLastACFailureReason,
+-- tlpUpsDeviceLastShutdownReason, tlpUpsIdentNumFans, tlpUpsFanTable, tlpUpsInputWattHours,
+-- tlpUpsControlResetWattHours, tlpDeviceIdentNvrID, Added more notification to support new device events
+-- 05/06/2019 Added tlpUpsDeviceOutputCurrentPrecision
+-- Updated the UNITS to "0.01 Amps" for tlpUpsOutputLineCurrent
+-- Updated the description of tlpUpsOutputLineCurrent, tlpPduOutputCurrent, tlpPduOutputCurrentMin,
+-- tlpPduOutputCurrentMax, tlpAtsOutputCurrent, tlpAtsOutputCurrentMin and tlpAtsOutputCurrentMax
+-- 05/07/2019 Added tlpNotifyTest
+-- 06/18/2019 Added tlpNotificationsDeviceUnhandledFault, tlpNotificationsUpsLineConnectRelayFaultShutdown,
+-- tlpNotificationsUpsTransferToFaultBypass, tlpNotificationsUpsBypassPowerDistributionModuleDisconnected,
+-- tlpNotificationsUpsManualBypassActivatedFromUnsupportedMode, tlpNotificationsUpsOnBatteryTimeoutShutdown,
+-- tlpNotificationsUpsLowBatteryPercentageShutdown
+-- 09/17/2019 Added tlpUpsIdentNumHeatsinks, tlpUpsIdentNumOutputContacts,tlpUpsIdentNumInputContacts,
+-- tlpUpsOutputLineApparentPower, tlpUpsControlCancelSelfTest, tlpUpsControlResetAllParameters,
+-- tlpUpsConfigLineQualifyTime, tlpUpsConfigACPowerSenseType, tlpUpsOutputPowerFactor, tlpUpsBatteryTotalMinutesOnBattery
+-- Added Tables: tlpUpsHeatsinkTable, tlpUpsOutputContactTable, tlpUpsInputContactTable, tlpUpsConfigVoltageTable.
+-- tlpUpsConfigContactTable, tlpUpsConfigOutputContactTable, tlpUpsConfigInputContactTable.
+-- Added more alarms to tlpAlarmsWellKnown section
+-- Added 'testing' to tlpUpsOutputSource
+-- Added UNITS and updated the description of tlpDeviceIdentCurrentUptime and tlpDeviceIdentTotalUptime
+---------------
+
+TRIPPLITE-PRODUCTS DEFINITIONS ::= BEGIN
+
+IMPORTS
+ DisplayString,
+ TruthValue,
+ TimeStamp,
+ RowStatus
+ FROM SNMPv2-TC
+ sysUpTime
+ FROM SNMPv2-MIB
+ OBJECT-GROUP,
+ NOTIFICATION-GROUP
+ FROM SNMPv2-CONF
+ MODULE-IDENTITY,
+ OBJECT-IDENTITY,
+ OBJECT-TYPE,
+ NOTIFICATION-TYPE,
+ Gauge32,
+ Integer32,
+ Unsigned32,
+ enterprises,
+ IpAddress,
+ TimeTicks
+ FROM SNMPv2-SMI
+ tripplite
+ FROM TRIPPLITE;
+
+tlpProducts MODULE-IDENTITY
+ LAST-UPDATED "201909270930Z"
+ ORGANIZATION "Tripp Lite"
+ CONTACT-INFO
+ "Software Engineering
+ Tripp Lite
+ 1111 W. 35th St.
+ Chicago, IL 60609"
+ DESCRIPTION
+ "This MIB module defines MIB objects which provide mechanisms for
+ remote management capabilities of Tripp Lite PowerAlert and related
+ software."
+ REVISION "201909270930Z"
+ DESCRIPTION
+ "Added tlpUpsIdentNumHeatsinks, tlpUpsIdentNumOutputContacts,tlpUpsIdentNumInputContacts,
+ tlpUpsOutputLineApparentPower, tlpUpsControlCancelSelfTest, tlpUpsControlResetAllParameters,
+ tlpUpsConfigLineQualifyTime, tlpUpsConfigACPowerSenseType, tlpUpsOutputPowerFactor,
+ Added Tables: tlpUpsHeatsinkTable, tlpUpsOutputContactTable, tlpUpsInputContactTable, tlpUpsConfigVoltageTable.
+ tlpUpsConfigContactTable, tlpUpsConfigOutputContactTable, tlpUpsConfigInputContactTable.
+ Added more alarm entries to tlpAlarmsWellKnown section
+ Added 'testing' to tlpUpsOutputSource
+ Added UNITS and updated the description of tlpDeviceIdentCurrentUptime and tlpDeviceIdentTotalUptime"
+ REVISION "201906180930Z"
+ DESCRIPTION
+ "Added tlpNotificationsDeviceUnhandledFault, tlpNotificationsUpsLineConnectRelayFaultShutdown,
+ tlpNotificationsUpsTransferToFaultBypass, tlpNotificationsUpsBypassPowerDistributionModuleDisconnected,
+ tlpNotificationsUpsManualBypassActivatedFromUnsupportedMode, tlpNotificationsUpsOnBatteryTimeoutShutdown,
+ tlpNotificationsUpsLowBatteryPercentageShutdown"
+ REVISION "201905071250Z"
+ DESCRIPTION
+ "Added tlpNotifyTest"
+ REVISION "201905061030Z"
+ DESCRIPTION
+ "Updated the UNITS to 0.01 Amps for tlpUpsOutputLineCurrent
+ Updated the description of tlpUpsOutputLineCurrent, tlpPduOutputCurrent, tlpPduOutputCurrentMin,
+ tlpPduOutputCurrentMax, tlpAtsOutputCurrent, tlpAtsOutputCurrentMin and tlpAtsOutputCurrentMax"
+ REVISION "201901171030Z"
+ DESCRIPTION
+ "Added tlpDeviceIdentFirmwareVersion2, tlpDeviceIdentFirmwareVersion3, tlpUpsDeviceLastACFailureReason,
+ tlpUpsDeviceLastShutdownReason, tlpUpsIdentNumFans, tlpUpsFanTable, tlpUpsInputWattHours,
+ tlpUpsControlResetWattHours, tlpDeviceIdentNvrID. Added more notification to support new device events"
+ REVISION "201807131430Z"
+ DESCRIPTION
+ "Added tlpPduOutputCalculatedPowerKVA, tlpPduOutputCalculatedPowerKW, tlpPduOutputCalculated24hrEnergy,
+ tlpAtsOutputCalculatedPowerKVA, tlpAtsOutputCalculatedPowerKW and tlpAtsOutputCalculated24hrEnergy"
+ REVISION "201805101430Z"
+ DESCRIPTION
+ "Updated the UNIT definition of tlpUpsDeviceTemperatureF, tlpUpsDeviceTemperatureC,
+ tlpPduInputLowTransferVoltageLowerBound, tlpPduInputLowTransferVoltageUpperBound,
+ tlpPduInputHighTransferVoltageLowerBound and tlpPduInputHighTransferVoltageUpperBound"
+ REVISION "201805081330Z"
+ DESCRIPTION
+ "Updated the description of tlpCoolingFanSpeed"
+ REVISION "201804301530Z"
+ DESCRIPTION
+ "Added tlpUpsOutputVARating"
+ REVISION "201804251330Z"
+ DESCRIPTION
+ "Obsoleted tlpAgentSnmpContactPrivPassword and tlpAgentSnmpContactAuthPassword"
+ REVISION "201803190730Z"
+ DESCRIPTION
+ "Added tlpCoolingWaterStatus"
+ REVISION "201801151130Z"
+ DESCRIPTION
+ "Updated/Corrected some descriptions and typos"
+ REVISION "201712291330Z"
+ DESCRIPTION
+ "Updated the output current OIDs description with regards to precision"
+ REVISION "201711301130Z"
+ DESCRIPTION
+ "Added tlpAtsOutputFrequency and tlpPduOutputFrequency"
+ REVISION "201709290800Z"
+ DESCRIPTION
+ "Added tlpCoolingCompressorStatus"
+ REVISION "201708300900Z"
+ DESCRIPTION
+ "Updated the description of tlpPduIdentNumBreakers and tlpAtsIdentNumBreakers"
+ REVISION "201707310900Z"
+ DESCRIPTION
+ "Added tlpPduConfigThresholdTable and new alarms to support Output Current Below Threshold events"
+ REVISION "201705231423Z"
+ DESCRIPTION
+ "Added more objects to Cooling section"
+ REVISION "201704192230Z"
+ DESCRIPTION
+ "Refactored tlpAtsConfigVoltageRangeTable"
+ REVISION "201704031533Z"
+ DESCRIPTION
+ "Refactored Cooling section"
+ REVISION "201702281600Z"
+ DESCRIPTION
+ "Corrected spelling errors."
+ REVISION "201701171250Z"
+ DESCRIPTION
+ "Changed tlpUpsBatteryDetailCurrent to signed with units of 0.01A.
+ This value was previous not reported by a device using prior units
+ of 0.1A; therefore, there no conflict exists with this change."
+ REVISION "201607111215Z"
+ DESCRIPTION
+ "Expanded tlpNotify for non-alarm notifications"
+ REVISION "201606221115Z"
+ DESCRIPTION
+ "Refactored MIB to extend from tripplite.mib"
+ REVISION "201603161210Z"
+ DESCRIPTION
+ "Expanded well known alarms"
+ REVISION "201602021115Z"
+ DESCRIPTION
+ "Redefined tlpUpsAlarmLoadLevelAboveThreshold"
+ REVISION "201601251230Z"
+ DESCRIPTION
+ "Redefined Reworked tlpAgentAttributes"
+ REVISION "201601201200Z"
+ DESCRIPTION
+ "Added tlpDeviceIdentUptime"
+ REVISION "201601081140Z"
+ DESCRIPTION
+ "Added tlpAtsConfigVoltageRangeLimitsTable"
+ REVISION "201511251300Z"
+ DESCRIPTION
+ "Refactored UPS, PDU and ATS input sections"
+ REVISION "201511101300Z"
+ DESCRIPTION
+ "Refactored tlpUps"
+ REVISION "201510161230Z"
+ DESCRIPTION
+ "Added tlpAtsConfigSource#ReturnTime"
+ REVISION "201508191200Z"
+ DESCRIPTION
+ "Added tlpAtsConfigThresholdTable"
+ REVISION "201412041000Z"
+ DESCRIPTION
+ "Created ATS device-specific section"
+ REVISION "201404140900Z"
+ DESCRIPTION
+ "Consolidated and Released for PAL v12.07.007x"
+
+ ::= { tripplite 1 }
+
+-- tlpProducts OBJECT IDENTIFIER ::= { tripplite 1 }
+
+tlpHardware OBJECT IDENTIFIER ::= { tlpProducts 1 }
+tlpSoftware OBJECT IDENTIFIER ::= { tlpProducts 2 }
+tlpAlarms OBJECT IDENTIFIER ::= { tlpProducts 3 }
+tlpNotify OBJECT IDENTIFIER ::= { tlpProducts 4 }
+
+tlpDevice OBJECT IDENTIFIER ::= { tlpHardware 1 }
+tlpDeviceDetail OBJECT IDENTIFIER ::= { tlpHardware 2 }
+tlpDeviceTypes OBJECT IDENTIFIER ::= { tlpHardware 3 }
+
+tlpUps OBJECT IDENTIFIER ::= { tlpDeviceTypes 1 }
+tlpPdu OBJECT IDENTIFIER ::= { tlpDeviceTypes 2 }
+tlpEnvirosense OBJECT IDENTIFIER ::= { tlpDeviceTypes 3 }
+tlpAts OBJECT IDENTIFIER ::= { tlpDeviceTypes 4 }
+tlpCooling OBJECT IDENTIFIER ::= { tlpDeviceTypes 5 }
+tlpKvm OBJECT IDENTIFIER ::= { tlpDeviceTypes 6 }
+tlpRackTrack OBJECT IDENTIFIER ::= { tlpDeviceTypes 7 }
+tlpSwitch OBJECT IDENTIFIER ::= { tlpDeviceTypes 8 }
+
+tlpUpsIdent OBJECT IDENTIFIER ::= { tlpUps 1 }
+tlpUpsDevice OBJECT IDENTIFIER ::= { tlpUps 2 }
+tlpUpsDetail OBJECT IDENTIFIER ::= { tlpUps 3 }
+tlpUpsControl OBJECT IDENTIFIER ::= { tlpUps 4 }
+tlpUpsConfig OBJECT IDENTIFIER ::= { tlpUps 5 }
+
+tlpUpsBattery OBJECT IDENTIFIER ::= { tlpUpsDetail 1 }
+tlpUpsInput OBJECT IDENTIFIER ::= { tlpUpsDetail 2 }
+tlpUpsOutput OBJECT IDENTIFIER ::= { tlpUpsDetail 3 }
+tlpUpsBypass OBJECT IDENTIFIER ::= { tlpUpsDetail 4 }
+tlpUpsOutlet OBJECT IDENTIFIER ::= { tlpUpsDetail 5 }
+tlpUpsWatchdog OBJECT IDENTIFIER ::= { tlpUpsDetail 6 }
+tlpUpsFan OBJECT IDENTIFIER ::= { tlpUpsDetail 7 }
+tlpUpsHeatsink OBJECT IDENTIFIER ::= { tlpUpsDetail 8 }
+tlpUpsContact OBJECT IDENTIFIER ::= { tlpUpsDetail 9 }
+
+tlpUpsInputContact OBJECT IDENTIFIER ::= { tlpUpsContact 1 }
+tlpUpsOutputContact OBJECT IDENTIFIER ::= { tlpUpsContact 2 }
+
+tlpPduIdent OBJECT IDENTIFIER ::= { tlpPdu 1 }
+tlpPduDevice OBJECT IDENTIFIER ::= { tlpPdu 2 }
+tlpPduDetail OBJECT IDENTIFIER ::= { tlpPdu 3 }
+tlpPduControl OBJECT IDENTIFIER ::= { tlpPdu 4 }
+tlpPduConfig OBJECT IDENTIFIER ::= { tlpPdu 5 }
+
+tlpPduInput OBJECT IDENTIFIER ::= { tlpPduDetail 1 }
+tlpPduOutput OBJECT IDENTIFIER ::= { tlpPduDetail 2 }
+tlpPduOutlet OBJECT IDENTIFIER ::= { tlpPduDetail 3 }
+tlpPduCircuit OBJECT IDENTIFIER ::= { tlpPduDetail 4 }
+tlpPduBreaker OBJECT IDENTIFIER ::= { tlpPduDetail 5 }
+tlpPduHeatsink OBJECT IDENTIFIER ::= { tlpPduDetail 6 }
+
+tlpEnvIdent OBJECT IDENTIFIER ::= { tlpEnvirosense 1 }
+-- tlpEnvDevice OBJECT IDENTIFIER ::= { tlpEnvirosense 2 }
+tlpEnvDetail OBJECT IDENTIFIER ::= { tlpEnvirosense 3 }
+-- tlpEnvControl OBJECT IDENTIFIER ::= { tlpEnvirosense 4 }
+tlpEnvConfig OBJECT IDENTIFIER ::= { tlpEnvirosense 5 }
+
+tlpAtsIdent OBJECT IDENTIFIER ::= { tlpAts 1 }
+tlpAtsDevice OBJECT IDENTIFIER ::= { tlpAts 2 }
+tlpAtsDetail OBJECT IDENTIFIER ::= { tlpAts 3 }
+tlpAtsControl OBJECT IDENTIFIER ::= { tlpAts 4 }
+tlpAtsConfig OBJECT IDENTIFIER ::= { tlpAts 5 }
+
+tlpAtsInput OBJECT IDENTIFIER ::= { tlpAtsDetail 1 }
+tlpAtsOutput OBJECT IDENTIFIER ::= { tlpAtsDetail 2 }
+tlpAtsOutlet OBJECT IDENTIFIER ::= { tlpAtsDetail 3 }
+tlpAtsCircuit OBJECT IDENTIFIER ::= { tlpAtsDetail 4 }
+tlpAtsBreaker OBJECT IDENTIFIER ::= { tlpAtsDetail 5 }
+tlpAtsHeatsink OBJECT IDENTIFIER ::= { tlpAtsDetail 6 }
+
+tlpCoolingIdent OBJECT IDENTIFIER ::= { tlpCooling 1 }
+tlpCoolingDevice OBJECT IDENTIFIER ::= { tlpCooling 2 }
+tlpCoolingDetail OBJECT IDENTIFIER ::= { tlpCooling 3 }
+tlpCoolingControl OBJECT IDENTIFIER ::= { tlpCooling 4 }
+tlpCoolingConfig OBJECT IDENTIFIER ::= { tlpCooling 5 }
+
+tlpCoolingTemperature OBJECT IDENTIFIER ::= { tlpCoolingDetail 1 }
+tlpCoolingPressure OBJECT IDENTIFIER ::= { tlpCoolingDetail 2 }
+
+tlpKvmIdent OBJECT IDENTIFIER ::= { tlpKvm 1 }
+tlpKvmDevice OBJECT IDENTIFIER ::= { tlpKvm 2 }
+tlpKvmDetail OBJECT IDENTIFIER ::= { tlpKvm 3 }
+tlpKvmControl OBJECT IDENTIFIER ::= { tlpKvm 4 }
+tlpKvmConfig OBJECT IDENTIFIER ::= { tlpKvm 5 }
+
+tlpRackTrackIdent OBJECT IDENTIFIER ::= { tlpRackTrack 1 }
+tlpRackTrackDevice OBJECT IDENTIFIER ::= { tlpRackTrack 2 }
+tlpRackTrackDetail OBJECT IDENTIFIER ::= { tlpRackTrack 3 }
+tlpRackTrackControl OBJECT IDENTIFIER ::= { tlpRackTrack 4 }
+tlpRackTrackConfig OBJECT IDENTIFIER ::= { tlpRackTrack 5 }
+
+tlpSwitchIdent OBJECT IDENTIFIER ::= { tlpSwitch 1 }
+tlpSwitchDevice OBJECT IDENTIFIER ::= { tlpSwitch 2 }
+tlpSwitchDetail OBJECT IDENTIFIER ::= { tlpSwitch 3 }
+tlpSwitchControl OBJECT IDENTIFIER ::= { tlpSwitch 4 }
+tlpSwitchConfig OBJECT IDENTIFIER ::= { tlpSwitch 5 }
+
+tlpAgentDetails OBJECT IDENTIFIER ::= { tlpSoftware 1 }
+tlpAgentSettings OBJECT IDENTIFIER ::= { tlpSoftware 2 }
+tlpAgentContacts OBJECT IDENTIFIER ::= { tlpSoftware 3 }
+
+tlpAgentIdent OBJECT IDENTIFIER ::= { tlpAgentDetails 1}
+tlpAgentAttributes OBJECT IDENTIFIER ::= { tlpAgentDetails 2}
+
+tlpAgentConfig OBJECT IDENTIFIER ::= { tlpAgentSettings 1}
+
+tlpAgentEmailContacts OBJECT IDENTIFIER ::= { tlpAgentContacts 1}
+tlpAgentSnmpContacts OBJECT IDENTIFIER ::= { tlpAgentContacts 2}
+
+tlpAlarmsWellKnown OBJECT IDENTIFIER ::= { tlpAlarms 3 }
+tlpAlarmControl OBJECT IDENTIFIER ::= { tlpAlarms 4 }
+
+tlpAgentAlarms OBJECT IDENTIFIER ::= { tlpAlarmsWellKnown 1 }
+tlpDeviceAlarms OBJECT IDENTIFIER ::= { tlpAlarmsWellKnown 2 }
+tlpUpsAlarms OBJECT IDENTIFIER ::= { tlpAlarmsWellKnown 3 }
+tlpPduAlarms OBJECT IDENTIFIER ::= { tlpAlarmsWellKnown 4 }
+tlpEnvAlarms OBJECT IDENTIFIER ::= { tlpAlarmsWellKnown 5 }
+tlpAtsAlarms OBJECT IDENTIFIER ::= { tlpAlarmsWellKnown 6 }
+tlpCoolingAlarms OBJECT IDENTIFIER ::= { tlpAlarmsWellKnown 7 }
+tlpKvmAlarms OBJECT IDENTIFIER ::= { tlpAlarmsWellKnown 8 }
+tlpRackTrackAlarms OBJECT IDENTIFIER ::= { tlpAlarmsWellKnown 9 }
+tlpSwitchAlarms OBJECT IDENTIFIER ::= { tlpAlarmsWellKnown 10 }
+
+
+tlpNotifications OBJECT IDENTIFIER ::= { tlpNotify 1 }
+tlpNotificationsEvent OBJECT IDENTIFIER ::= { tlpNotify 2 }
+tlpNotificationsEventParameters OBJECT IDENTIFIER ::= { tlpNotify 3 }
+
+tlpDeviceNumDevices OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of devices that this agent is currently managing."
+ ::= { tlpDevice 1 }
+
+tlpDeviceTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpDeviceEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of device table entries. The number of entries
+ is given by the value of tlpDevicesNumDevices."
+ ::= { tlpDevice 2 }
+
+tlpDeviceEntry OBJECT-TYPE
+ SYNTAX TlpDeviceEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing information applicable to a particular device
+ managed by this agent."
+ INDEX { tlpDeviceIndex }
+ ::= { tlpDeviceTable 1 }
+
+TlpDeviceEntry ::= SEQUENCE {
+ tlpDeviceIndex Unsigned32,
+ tlpDeviceRowStatus RowStatus,
+ tlpDeviceType OBJECT IDENTIFIER,
+ tlpDeviceManufacturer DisplayString,
+ tlpDeviceModel DisplayString,
+ tlpDeviceName DisplayString,
+ tlpDeviceID INTEGER,
+ tlpDeviceLocation DisplayString,
+ tlpDeviceRegion DisplayString,
+ tlpDeviceStatus INTEGER }
+
+tlpDeviceIndex OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The table row index for the device."
+ ::= { tlpDeviceEntry 1 }
+
+tlpDeviceRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Used with table edits to indicate the status of a given row in
+ tlpDeviceTable."
+ ::= { tlpDeviceEntry 2 }
+
+tlpDeviceType OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The type of device. One of the appropriate hardware types:
+ ups, pdu, envirosense, etc."
+ ::= { tlpDeviceEntry 3 }
+
+tlpDeviceManufacturer OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The name of the manufacturer."
+ ::= { tlpDeviceEntry 4 }
+
+tlpDeviceModel OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The model designation."
+ ::= { tlpDeviceEntry 5 }
+
+tlpDeviceName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A user-supplied name for the device."
+ ::= { tlpDeviceEntry 6 }
+
+tlpDeviceID OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A user-supplied ID for the device."
+ ::= { tlpDeviceEntry 7 }
+
+tlpDeviceLocation OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A user-supplied location for the device."
+ ::= { tlpDeviceEntry 8 }
+
+tlpDeviceRegion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A user-supplied region for the device."
+ ::= { tlpDeviceEntry 9 }
+
+tlpDeviceStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(0),
+ critical(1),
+ warning(2),
+ info(3),
+ status(4),
+ offline(5),
+ custom(6),
+ configuration(7) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The currently most critical alarm status for the device."
+ ::= { tlpDeviceEntry 10 }
+
+tlpDeviceIdentTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpDeviceIdentEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The identity details of each device in device table. The number
+ of entries is given by the value of tlpDevicesNumDevices."
+ ::= { tlpDeviceDetail 1 }
+
+tlpDeviceIdentEntry OBJECT-TYPE
+ SYNTAX TlpDeviceIdentEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing details for a particular device."
+ INDEX { tlpDeviceIndex }
+ ::= { tlpDeviceIdentTable 1 }
+
+TlpDeviceIdentEntry ::= SEQUENCE {
+ tlpDeviceIdentProtocol DisplayString,
+ tlpDeviceIdentCommPortType INTEGER,
+ tlpDeviceIdentCommPortName DisplayString,
+ tlpDeviceIdentFirmwareVersion DisplayString,
+ tlpDeviceIdentSerialNum DisplayString,
+ tlpDeviceIdentDateInstalled DisplayString,
+ tlpDeviceIdentHardwareVersion DisplayString,
+ tlpDeviceIdentCurrentUptime DisplayString,
+ tlpDeviceIdentTotalUptime DisplayString,
+ tlpDeviceIdentFirmwareVersion2 DisplayString,
+ tlpDeviceIdentFirmwareVersion3 DisplayString,
+ tlpDeviceIdentNvrID DisplayString }
+
+tlpDeviceIdentProtocol OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The Tripplite protocol used to communicate with the device."
+ ::= { tlpDeviceIdentEntry 1 }
+
+tlpDeviceIdentCommPortType OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(0),
+ serial(1),
+ usb(2),
+ hid(3),
+ simulated(4),
+ unittest(5) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The type of communications port used to connect with the device."
+ ::= { tlpDeviceIdentEntry 2 }
+
+tlpDeviceIdentCommPortName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The name of the communications port."
+ ::= { tlpDeviceIdentEntry 3 }
+
+tlpDeviceIdentFirmwareVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The firmware version of the device."
+ ::= { tlpDeviceIdentEntry 4 }
+
+tlpDeviceIdentSerialNum OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The serial number of the device."
+ ::= { tlpDeviceIdentEntry 5 }
+
+tlpDeviceIdentDateInstalled OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The installation date for this device in the format of mm/dd/yyyy."
+ ::= { tlpDeviceIdentEntry 6 }
+
+tlpDeviceIdentHardwareVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The hardware revision of the device. This value will return ERROR_NO_SUCH_NAME
+ if not supported by the device."
+ ::= { tlpDeviceIdentEntry 7 }
+
+tlpDeviceIdentCurrentUptime OBJECT-TYPE
+ SYNTAX DisplayString
+ UNITS "hours"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The device uptime since its last startup. This value will return
+ ERROR_NO_SUCH_NAME if not supported by the device."
+ ::= { tlpDeviceIdentEntry 8 }
+
+tlpDeviceIdentTotalUptime OBJECT-TYPE
+ SYNTAX DisplayString
+ UNITS "days"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The cumulative (total) uptime for the device. This value will return
+ ERROR_NO_SUCH_NAME if not supported by the device."
+ ::= { tlpDeviceIdentEntry 9 }
+
+tlpDeviceIdentFirmwareVersion2 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The firmware version of second IC on the device. This value will return
+ ERROR_NO_SUCH_NAME if not supported by the device."
+ ::= { tlpDeviceIdentEntry 10 }
+
+tlpDeviceIdentFirmwareVersion3 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The firmware version of third IC on the device. This value will return
+ ERROR_NO_SUCH_NAME if not supported by the device."
+ ::= { tlpDeviceIdentEntry 11 }
+
+tlpDeviceIdentNvrID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The id of NVRAM. This value will return ERROR_NO_SUCH_NAME if not supported by the device."
+ ::= { tlpDeviceIdentEntry 12 }
+
+-- ups
+
+tlpUpsIdentNumUps OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of ups devices that this agent is currently managing."
+ ::= { tlpUpsIdent 1 }
+
+tlpUpsIdentTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpUpsIdentEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The identity details of each ups in device table. This is a
+ sparse dependent table, and will contain some subset of devices
+ that are upss."
+ ::= { tlpUpsIdent 2 }
+
+tlpUpsIdentEntry OBJECT-TYPE
+ SYNTAX TlpUpsIdentEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing details for a particular ups."
+ INDEX { tlpDeviceIndex }
+ ::= { tlpUpsIdentTable 1 }
+
+TlpUpsIdentEntry ::= SEQUENCE {
+ tlpUpsIdentNumInputs Unsigned32,
+ tlpUpsIdentNumOutputs Unsigned32,
+ tlpUpsIdentNumBypass Unsigned32,
+ tlpUpsIdentNumPhases Unsigned32,
+ tlpUpsIdentNumOutlets Unsigned32,
+ tlpUpsIdentNumOutletGroups Unsigned32,
+ tlpUpsIdentNumBatteryPacks Unsigned32,
+ tlpUpsIdentNumFans Unsigned32,
+ tlpUpsIdentNumHeatsinks Unsigned32,
+ tlpUpsIdentNumInputContacts Unsigned32,
+ tlpUpsIdentNumOutputContacts Unsigned32 }
+
+tlpUpsIdentNumInputs OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of input lines supported by the ups."
+ ::= { tlpUpsIdentEntry 1 }
+
+tlpUpsIdentNumOutputs OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of output lines supported by the ups."
+ ::= { tlpUpsIdentEntry 2 }
+
+tlpUpsIdentNumBypass OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of bypass lines supported by the ups."
+ ::= { tlpUpsIdentEntry 3 }
+
+tlpUpsIdentNumPhases OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of phases supported by the ups."
+ ::= { tlpUpsIdentEntry 4 }
+
+tlpUpsIdentNumOutlets OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of receptacles supported by the ups."
+ ::= { tlpUpsIdentEntry 5 }
+
+tlpUpsIdentNumOutletGroups OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of receptacle groups supported by the ups."
+ ::= { tlpUpsIdentEntry 6 }
+
+tlpUpsIdentNumBatteryPacks OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of battery packs, internal and external combined,
+ supported by the ups."
+ ::= { tlpUpsIdentEntry 7 }
+
+tlpUpsIdentNumFans OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of fans supported by the ups."
+ ::= { tlpUpsIdentEntry 8 }
+
+tlpUpsIdentNumHeatsinks OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of heatsink thermistors supported by the ups."
+ ::= { tlpUpsIdentEntry 9 }
+
+tlpUpsIdentNumInputContacts OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of input contacts supported by the ups."
+ ::= { tlpUpsIdentEntry 10 }
+
+tlpUpsIdentNumOutputContacts OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of output contacts supported by the ups."
+ ::= { tlpUpsIdentEntry 11 }
+
+tlpUpsSupportsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpUpsSupportsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The supported details of each ups in device table. This is a
+ sparse dependent table, and will contain some subset of devices
+ that are upss."
+ ::= { tlpUpsIdent 3 }
+
+tlpUpsSupportsEntry OBJECT-TYPE
+ SYNTAX TlpUpsSupportsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing supported details for a particular ups."
+ INDEX { tlpDeviceIndex }
+ ::= { tlpUpsSupportsTable 1 }
+
+TlpUpsSupportsEntry ::= SEQUENCE {
+ tlpUpsSupportsEnergywise TruthValue,
+ tlpUpsSupportsRampShed TruthValue,
+ tlpUpsSupportsOutletGroup TruthValue,
+ tlpUpsSupportsOutletCurrentPower TruthValue,
+ tlpUpsSupportsOutletVoltage TruthValue }
+
+tlpUpsSupportsEnergywise OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates whether the ups supports Cisco EnergyWise."
+ ::= { tlpUpsSupportsEntry 1 }
+
+tlpUpsSupportsRampShed OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates whether the ups supports ramping and shedding."
+ ::= { tlpUpsSupportsEntry 2 }
+
+tlpUpsSupportsOutletGroup OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates whether the ups supports outlet groups."
+ ::= { tlpUpsSupportsEntry 3 }
+
+tlpUpsSupportsOutletCurrentPower OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates whether the ups reports individual receptacle current
+ and power measurements. Devices that do not support individual
+ receptacle measurements will always return ERROR_NO_SUCH_NAME for
+ tlpUpsOutletCurrent and tlpUpsOutletPower."
+ ::= { tlpUpsSupportsEntry 4 }
+
+tlpUpsSupportsOutletVoltage OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates whether the ups reports individual receptacle voltage
+ measurements. Devices that do not support individual receptacle
+ measurements will always return ERROR_NO_SUCH_NAME for
+ tlpUpsOutletVoltage."
+ ::= { tlpUpsSupportsEntry 5 }
+
+tlpUpsDeviceTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpUpsDeviceEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The device details of each ups in device table. This is a
+ sparse dependent table, and will contain some subset of devices
+ that are upss."
+ ::= { tlpUpsDevice 1 }
+
+tlpUpsDeviceEntry OBJECT-TYPE
+ SYNTAX TlpUpsDeviceEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing device details for a particular ups."
+ INDEX { tlpDeviceIndex }
+ ::= { tlpUpsDeviceTable 1 }
+
+TlpUpsDeviceEntry ::= SEQUENCE {
+ tlpUpsDeviceMainLoadState INTEGER,
+ tlpUpsDeviceMainLoadControllable TruthValue,
+ tlpUpsDeviceMainLoadCommand INTEGER,
+ tlpUpsDevicePowerOnDelay Integer32,
+ tlpUpsDeviceTestDate DisplayString,
+ tlpUpsDeviceTestResultsStatus INTEGER,
+ tlpUpsDeviceTemperatureC Integer32,
+ tlpUpsDeviceTemperatureF Integer32,
+ tlpUpsDeviceLastACFailureReason INTEGER,
+ tlpUpsDeviceLastShutdownReason INTEGER,
+ tlpUpsDeviceOutputCurrentPrecision INTEGER }
+
+tlpUpsDeviceMainLoadState OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(0),
+ off(1),
+ on(2) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current state of the main output of the device."
+ ::= { tlpUpsDeviceEntry 1 }
+
+tlpUpsDeviceMainLoadControllable OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates whether or not the main output is controllable, and whether
+ the ups can be turned off and on."
+ ::= { tlpUpsDeviceEntry 2 }
+
+tlpUpsDeviceMainLoadCommand OBJECT-TYPE
+ SYNTAX INTEGER {
+ idle(0),
+ turnOff(1),
+ turnOn(2),
+ cycle(3) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Reading this value will always return 0. Setting this value to
+ turnOff(1) will turn off the main output of the ups. Setting this
+ value to turnOn(2) will turn on the main output of the ups. Setting
+ this value to cycle(3) will turn off the main output, then turn it
+ back on."
+ ::= { tlpUpsDeviceEntry 3 }
+
+tlpUpsDevicePowerOnDelay OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The configurable delay value, which sets the amount of additional
+ time a given device will wait before it connects to a valid AC
+ source. By default the delay value is set to 0."
+ ::= { tlpUpsDeviceEntry 4 }
+
+tlpUpsDeviceTestDate OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The date of the last self-test run on the ups, in the format YYYY-MM-DD."
+ ::= { tlpUpsDeviceEntry 5 }
+
+tlpUpsDeviceTestResultsStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ noTest(0),
+ doneAndPassed(1),
+ doneAndWarning(2),
+ doneAndError(3),
+ aborted(4),
+ inProgress(5),
+ noTestInitiated(6),
+ badBattery(7),
+ overCurrent(8),
+ batteryFailed(9) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The result of the last self-test run on the ups."
+ ::= { tlpUpsDeviceEntry 6 }
+
+tlpUpsDeviceTemperatureC OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 degrees Celsius"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The ambient temperature at or near the ups casing. Temperature
+ measurements are not supported on all models. If not supported,
+ this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpUpsDeviceEntry 7 }
+
+tlpUpsDeviceTemperatureF OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 degrees Fahrenheit"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The ambient temperature at or near the ups casing. Temperature
+ measurements are not supported on all models. If not supported,
+ this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpUpsDeviceEntry 8 }
+
+tlpUpsDeviceLastACFailureReason OBJECT-TYPE
+ SYNTAX INTEGER {
+ noACFailureSinceReset(0),
+ blackout(1),
+ instantaneousHighLineFrequency(2),
+ highLineVoltage(3),
+ lowLineVoltage(4),
+ averageFrequencyFault(5),
+ instantaneousLowLineFrequency(6),
+ delayedBrownout(7) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The last AC failure reason."
+ ::= { tlpUpsDeviceEntry 9 }
+
+tlpUpsDeviceLastShutdownReason OBJECT-TYPE
+ SYNTAX INTEGER {
+ noShutdownSinceReset(0),
+ onOffButtonShutdown(1),
+ averageVbattSmallerThenLVCShutdown(2),
+ fastVbattKeepaliveVoltageFastShutdown(3),
+ averageCurrentLimitShutdown(4),
+ fastCurrentLimitShutdown(5),
+ heavyLoadThermalTimeLimitShutdown(6),
+ fixedInvertModeTimeLimitShutdown(7),
+ highBatteryVoltageFault(8),
+ averageVbattKeepaliveVoltageShutdown(9),
+ shutdownCommandWithAutorestartEnabled(10),
+ shutdownCommandWithoutAutorestartEnabled(11),
+ lineConnectRelayFault(12),
+ epoInvertMode(13),
+ epoRebootMode(14),
+ invalidLineStandbyMode(15),
+ chargerLimitMinBatteryVoltage(16),
+ chargerLimitMaxBatteryVoltage(17),
+ invalidLineDelayedWakeupAutorestartEnabled(18),
+ invalidLineDelayedWakeupAutorestartDisabled(19),
+ minBatteryVoltagePriorDelayedWakeupAutorestartEnabled(20),
+ minBatteryVoltagePriorDelayedWakeupAutorestartDisabled(21),
+ lvcShutdownAutorestartEnabled(22),
+ lvcShutdownAutorestartDisabled(23),
+ overloadShutdownAutorestartEnabled(24),
+ overloadShutdownAutorestartDisabled(25),
+ overTemperatureShutdownAutorestartEnabled(26),
+ overTemperatureShutdownAutorestartDisabled(27),
+ onOffButtonShutdownAutorestartEnabled(28),
+ onOffButtonShutdownAutorestartDisabled(29),
+ batteryReportedFault(30),
+ batteryCommunicationLost(31),
+ batteryJumpStartChargerTimeoutError(32) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The last unit shut down reason."
+ ::= { tlpUpsDeviceEntry 10 }
+
+tlpUpsDeviceOutputCurrentPrecision OBJECT-TYPE
+ SYNTAX INTEGER {
+ wholeNumber(0),
+ tenths(1),
+ hundredths(2) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Output current is reported by tlpUpsOutputLineCurrent, tlpUpsOutputLineCurrentMin and
+ tlpUpsOutputLineCurrentMax. These values are all reported in hundredths(0.01A),which
+ accommodates all models; however, on any given device the actual precision may vary. This
+ value describes the actual precision, which can be used as a divisor against the output current
+ values to obtain the true output current measurement. For example, if tlpUpsOutputLineCurrent reports
+ 530 and tlpUpsDeviceOutputCurrentPrecision is tenths(1), then the actual output current is 5.3."
+ ::= { tlpUpsDeviceEntry 11 }
+
+tlpUpsBatterySummaryTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpUpsBatterySummaryEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The battery system summary of each ups in the device
+ table. This is a sparse dependent table, and will contain the
+ number of entries based upon the number of upss managed by
+ the agent as reported by tlpUpsIdentNumUps."
+ ::= { tlpUpsBattery 1 }
+
+tlpUpsBatterySummaryEntry OBJECT-TYPE
+ SYNTAX TlpUpsBatterySummaryEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing information applicable to a particular
+ battery system managed by this agent."
+ INDEX { tlpDeviceIndex }
+ ::= { tlpUpsBatterySummaryTable 1 }
+
+TlpUpsBatterySummaryEntry ::= SEQUENCE {
+ tlpUpsBatteryStatus INTEGER,
+ tlpUpsSecondsOnBattery Unsigned32,
+ tlpUpsEstimatedMinutesRemaining Unsigned32,
+ tlpUpsEstimatedChargeRemaining INTEGER,
+ tlpUpsBatteryRunTimeRemaining TimeTicks,
+ tlpUpsBatteryTotalMinutesOnBattery Unsigned32 }
+
+tlpUpsBatteryStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(1),
+ batteryNormal(2),
+ batteryLow(3),
+ batteryDepleted(4) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The indication of the capacity remaining in the UPS system's
+ batteries. A value of batteryNormal indicates that the
+ remaining run-time is greater than tlpUpsConfigLowBattTime. A
+ value of batteryLow indicates that the remaining battery run-time
+ is less than or equal to tlpUpsConfigLowBattTime. A value of
+ batteryDepleted indicates that the UPS will be unable to sustain
+ the present load when and if the utility power is lost (including
+ the possibility that the utility power is currently absent and
+ the UPS is unable to sustain the output)."
+ ::= { tlpUpsBatterySummaryEntry 1 }
+
+tlpUpsSecondsOnBattery OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "seconds"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "If the unit is on battery power, the elapsed time since the UPS
+ last switched to battery power, or the time since the network
+ management subsystem was last restarted, whichever is less. Zero
+ shall be returned if the unit is not on battery power."
+ ::= { tlpUpsBatterySummaryEntry 2 }
+
+tlpUpsEstimatedMinutesRemaining OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "minutes"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An estimate of the time to battery charge depletion
+ under the present load conditions if the utility power
+ is off and remains off, or if it were to be lost and
+ remain off."
+ ::= { tlpUpsBatterySummaryEntry 3 }
+
+tlpUpsEstimatedChargeRemaining OBJECT-TYPE
+ SYNTAX INTEGER (0..100)
+ UNITS "percent"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An estimate of the battery charge remaining expressed
+ as a percent of full charge."
+ ::= { tlpUpsBatterySummaryEntry 4 }
+
+tlpUpsBatteryRunTimeRemaining OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The run time remaining before batteries are exhausted. If the device
+ does not support run time remaining, then the agent reports
+ ERROR_NO_SUCH_NAME."
+ ::= { tlpUpsBatterySummaryEntry 5 }
+
+tlpUpsBatteryTotalMinutesOnBattery OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "minutes"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total accumulative minutes the ups has run on the battery."
+ ::= { tlpUpsBatterySummaryEntry 6 }
+
+tlpUpsBatteryDetailTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpUpsBatteryDetailEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The battery detail of each ups in the device table. This is a sparse
+ dependent table, and will contain the number of entries based upon the
+ number of upss managed by the agent as reported by tlpUpsIdentNumUps."
+ ::= { tlpUpsBattery 2 }
+
+tlpUpsBatteryDetailEntry OBJECT-TYPE
+ SYNTAX TlpUpsBatteryDetailEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing information applicable to a particular
+ battery system managed by this agent."
+ INDEX { tlpDeviceIndex }
+ ::= { tlpUpsBatteryDetailTable 1 }
+
+TlpUpsBatteryDetailEntry ::= SEQUENCE {
+ tlpUpsBatteryDetailVoltage Unsigned32,
+ tlpUpsBatteryDetailCurrent Integer32,
+ tlpUpsBatteryDetailCapacity INTEGER,
+ tlpUpsBatteryDetailCharge INTEGER,
+ tlpUpsBatteryDetailChargerStatus INTEGER }
+
+tlpUpsBatteryDetailVoltage OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Volt DC"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The magnitude of the present battery voltage."
+ ::= { tlpUpsBatteryDetailEntry 1 }
+
+tlpUpsBatteryDetailCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.01 Amps DC"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The present battery current."
+ ::= { tlpUpsBatteryDetailEntry 2 }
+
+tlpUpsBatteryDetailCapacity OBJECT-TYPE
+ SYNTAX INTEGER (0..100)
+ UNITS "percent"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The estimated remaining battery capacity expressed as a percent of
+ full capacity."
+ ::= { tlpUpsBatteryDetailEntry 3 }
+
+tlpUpsBatteryDetailCharge OBJECT-TYPE
+ SYNTAX INTEGER {
+ floating(0),
+ charging(1),
+ resting(2),
+ discharging(3),
+ normal(4),
+ standby(5) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Denotes the charge state of the battery."
+ ::= { tlpUpsBatteryDetailEntry 4 }
+
+tlpUpsBatteryDetailChargerStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ ok(0),
+ inFaultCondition(1) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The status of the battery charger. If the device does not support this
+ value, then the agent will report ERROR_NO_SUCH_NAME."
+ ::= { tlpUpsBatteryDetailEntry 5 }
+
+tlpUpsBatteryPackIdentTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpUpsBatteryIdentEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The battery identification details for each ups in the device
+ table. This is a sparse dependent table, and will contain the
+ number of entries based upon the number of upss managed by the
+ agent as reported by upsIdentNumUps and the number of battery
+ battery packs per each as reported by tlpUpsNumBatteryPacks."
+ ::= { tlpUpsBattery 3 }
+
+tlpUpsBatteryPackIdentEntry OBJECT-TYPE
+ SYNTAX TlpUpsBatteryIdentEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing information applicable to a particular
+ battery pack managed by this agent."
+ INDEX { tlpDeviceIndex, tlpUpsBatteryPackIdentIndex }
+ ::= { tlpUpsBatteryPackIdentTable 1 }
+
+TlpUpsBatteryIdentEntry ::= SEQUENCE {
+ tlpUpsBatteryPackIdentIndex Unsigned32,
+ tlpUpsBatteryPackIdentManufacturer DisplayString,
+ tlpUpsBatteryPackIdentModel DisplayString,
+ tlpUpsBatteryPackIdentSerialNum DisplayString,
+ tlpUpsBatteryPackIdentFirmware DisplayString,
+ tlpUpsBatteryPackIdentSKU DisplayString }
+
+tlpUpsBatteryPackIdentIndex OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The table row index for the ups battery pack."
+ ::= { tlpUpsBatteryPackIdentEntry 1 }
+
+tlpUpsBatteryPackIdentManufacturer OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The manufacturer of the battery pack. If the device does not
+ support this value, then the agent reports ERROR_NO_SUCH_NAME."
+ ::= { tlpUpsBatteryPackIdentEntry 2 }
+
+tlpUpsBatteryPackIdentModel OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The model or device name of the battery pack. If the device does not
+ support this value, then the agent reports ERROR_NO_SUCH_NAME."
+ ::= { tlpUpsBatteryPackIdentEntry 3 }
+
+tlpUpsBatteryPackIdentSerialNum OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The serial number of the battery pack. If the device does not support
+ this value, then the agent reports ERROR_NO_SUCH_NAME."
+ ::= { tlpUpsBatteryPackIdentEntry 4 }
+
+tlpUpsBatteryPackIdentFirmware OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The firmware of the battery pack. If the device does not support this
+ value, then the agent reports ERROR_NO_SUCH_NAME."
+ ::= { tlpUpsBatteryPackIdentEntry 5 }
+
+tlpUpsBatteryPackIdentSKU OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The SKU of the battery pack. If the device does not support this value,
+ then the agent reports ERROR_NO_SUCH_NAME."
+ ::= { tlpUpsBatteryPackIdentEntry 6 }
+
+tlpUpsBatteryPackConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpUpsBatteryConfigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The battery configuration details for each ups in the device
+ table. This is a sparse dependent table, and will contain the
+ number of entries based upon the number of upss managed by the
+ agent as reported by upsIdentNumUps and the number of battery
+ battery packs per each as reported by tlpUpsNumBatteryPacks."
+ ::= { tlpUpsBattery 4 }
+
+tlpUpsBatteryPackConfigEntry OBJECT-TYPE
+ SYNTAX TlpUpsBatteryConfigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing information applicable to a particular
+ battery pack managed by this agent."
+ INDEX { tlpDeviceIndex, tlpUpsBatteryPackIdentIndex }
+ ::= { tlpUpsBatteryPackConfigTable 1 }
+
+TlpUpsBatteryConfigEntry ::= SEQUENCE {
+ tlpUpsBatteryPackConfigChemistry INTEGER,
+ tlpUpsBatteryPackConfigStyle INTEGER,
+ tlpUpsBatteryPackConfigLocation INTEGER,
+ tlpUpsBatteryPackConfigStrings Unsigned32,
+ tlpUpsBatteryPackConfigBatteriesPerString Unsigned32,
+ tlpUpsBatteryPackConfigCellsPerBattery INTEGER,
+ tlpUpsBatteryPackConfigNumBatteries Unsigned32,
+ tlpUpsBatteryPackConfigCapacityUnits INTEGER,
+ tlpUpsBatteryPackConfigDesignCapacity Unsigned32,
+ tlpUpsBatteryPackConfigCellCapacity Unsigned32,
+ tlpUpsBatteryPackConfigMinCellVoltage Unsigned32,
+ tlpUpsBatteryPackConfigMaxCellVoltage Unsigned32 }
+
+tlpUpsBatteryPackConfigChemistry OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(0),
+ leadAcid(1),
+ nickelCadmium(2),
+ lithiumIon(3) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The type of battery pack."
+ ::= { tlpUpsBatteryPackConfigEntry 1 }
+
+tlpUpsBatteryPackConfigStyle OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(0),
+ nonsmart(1),
+ smart(2),
+ bms(3) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The style of battery pack."
+ ::= { tlpUpsBatteryPackConfigEntry 2 }
+
+tlpUpsBatteryPackConfigLocation OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(0),
+ internal(1),
+ external(2) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The location of the battery pack."
+ ::= { tlpUpsBatteryPackConfigEntry 3 }
+
+tlpUpsBatteryPackConfigStrings OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of series strings in parallel contained in the battery
+ pack. If the device does not support this value, then the agent will
+ report ERROR_NO_SUCH_NAME."
+ ::= { tlpUpsBatteryPackConfigEntry 4 }
+
+tlpUpsBatteryPackConfigBatteriesPerString OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of battery per each string in the battery pack. If the
+ device does not support this value, then the agent will report
+ ERROR_NO_SUCH_NAME."
+ ::= { tlpUpsBatteryPackConfigEntry 5 }
+
+tlpUpsBatteryPackConfigCellsPerBattery OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(0),
+ one(1),
+ two(2),
+ four(4),
+ six(6) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of cells per battery.."
+ ::= { tlpUpsBatteryPackConfigEntry 6 }
+
+tlpUpsBatteryPackConfigNumBatteries OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of batteries contained in the battery pack. If the device
+ does not support this value, then the agent will report ERROR_NO_SUCH_NAME."
+ ::= { tlpUpsBatteryPackConfigEntry 7 }
+
+tlpUpsBatteryPackConfigCapacityUnits OBJECT-TYPE
+ SYNTAX INTEGER {
+ mAHr(0),
+ mWHr(1) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The units of measurement used for tlpUpsBatteryPackConfigDesignCapacity and
+ tlpUpsBatteryPackConfigCellCapacity. If supported, this value will report either
+ mAHR(1), amps per hour, or mWhr(1), watts per hour. If the device does not
+ support this value, then the agent will report ERROR_NO_SUCH_NAME."
+ ::= { tlpUpsBatteryPackConfigEntry 8 }
+
+tlpUpsBatteryPackConfigDesignCapacity OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The theoretical or nominal capacity of the battery pack in the measurement
+ defined by tlpUpsBatteryPackConfigCapacityUnits. If the device does not support
+ this value, then the agent will report ERROR_NO_SUCH_NAME."
+ ::= { tlpUpsBatteryPackConfigEntry 9 }
+
+tlpUpsBatteryPackConfigCellCapacity OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The capacity of the batteries in the measurement defined by
+ tlpUpsBatteryPackConfigCapacityUnits. If the device does not support this value,
+ then the agent will report ERROR_NO_SUCH_NAME."
+ ::= { tlpUpsBatteryPackConfigEntry 10 }
+
+tlpUpsBatteryPackConfigMinCellVoltage OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The minimum cell voltage for the batteries. If the device does not support
+ this value, then the agent will report ERROR_NO_SUCH_NAME."
+ ::= { tlpUpsBatteryPackConfigEntry 11 }
+
+tlpUpsBatteryPackConfigMaxCellVoltage OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The maximum cell voltage for the batteries. If the device does not support
+ this value, then the agent will report ERROR_NO_SUCH_NAME."
+ ::= { tlpUpsBatteryPackConfigEntry 12 }
+
+tlpUpsBatteryPackDetailTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpUpsBatteryPackDetailEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The details of each battery pack for each ups in the device
+ table. This is a sparse dependent table, and will contain the
+ number of entries based upon the number of upss and battery
+ packs managed by the agent as reported by tlpUpsIdentNumUps
+ and tlpUpsIdentNumBatteryPacks."
+ ::= { tlpUpsBattery 5 }
+
+tlpUpsBatteryPackDetailEntry OBJECT-TYPE
+ SYNTAX TlpUpsBatteryPackDetailEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing information applicable to a particular
+ battery system managed by this agent."
+ INDEX { tlpDeviceIndex, tlpUpsBatteryPackIdentIndex }
+ ::= { tlpUpsBatteryPackDetailTable 1 }
+
+TlpUpsBatteryPackDetailEntry ::= SEQUENCE {
+ tlpUpsBatteryPackDetailCondition INTEGER,
+ tlpUpsBatteryPackDetailTemperatureC Unsigned32,
+ tlpUpsBatteryPackDetailTemperatureF Unsigned32,
+ tlpUpsBatteryPackDetailAge Unsigned32,
+ tlpUpsBatteryPackDetailLastReplaceDate DisplayString,
+ tlpUpsBatteryPackDetailNextReplaceDate DisplayString,
+ tlpUpsBatteryPackDetailCycleCount Unsigned32 }
+
+tlpUpsBatteryPackDetailCondition OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(0),
+ good(1),
+ weak(2),
+ bad(3) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The condition of the battery. A bad battery should be replaced."
+ ::= { tlpUpsBatteryPackDetailEntry 1 }
+
+tlpUpsBatteryPackDetailTemperatureC OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 degrees Celsius"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The ambient temperature at or near the UPS Battery casing."
+ ::= { tlpUpsBatteryPackDetailEntry 2 }
+
+tlpUpsBatteryPackDetailTemperatureF OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 degrees Fahrenheit"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The ambient temperature at or near the UPS Battery casing."
+ ::= { tlpUpsBatteryPackDetailEntry 3 }
+
+tlpUpsBatteryPackDetailAge OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Years"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The age of the battery in years. This is equal to the current
+ date minus tlpUpsBatteryPackIdentInstallDate."
+ ::= { tlpUpsBatteryPackDetailEntry 4 }
+
+tlpUpsBatteryPackDetailLastReplaceDate OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The date when the batteries were last replaced in YYYYMMDD format."
+ ::= { tlpUpsBatteryPackDetailEntry 5 }
+
+tlpUpsBatteryPackDetailNextReplaceDate OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The date when the batteries should next be replaced in YYYYMMDD
+ format."
+ ::= { tlpUpsBatteryPackDetailEntry 6 }
+
+tlpUpsBatteryPackDetailCycleCount OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of times the battery went into invert mode. This number
+ is incremented by 1 each time the unit goes on battery mode (with
+ the exception of Self Test mode). If the device does not support this
+ value, then the agent will report ERROR_NO_SUCH_NAME."
+ ::= { tlpUpsBatteryPackDetailEntry 7 }
+
+tlpUpsInputTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpUpsInputEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The input details of each ups in the device table. This is
+ a sparse dependent table, and will contain the number of entries
+ based upon the number of upss managed by the agent as reported
+ by tlpUpsIdentNumUps."
+ ::= { tlpUpsInput 1 }
+
+tlpUpsInputEntry OBJECT-TYPE
+ SYNTAX TlpUpsInputEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing information applicable to all input lines per
+ each ups managed by this agent."
+ INDEX { tlpDeviceIndex }
+ ::= { tlpUpsInputTable 1 }
+
+TlpUpsInputEntry ::= SEQUENCE {
+ tlpUpsInputLineBads INTEGER,
+ tlpUpsInputNominalVoltage Unsigned32,
+ tlpUpsInputNominalFrequency Unsigned32,
+ tlpUpsInputLowTransferVoltage Unsigned32,
+ tlpUpsInputLowTransferVoltageLowerBound Unsigned32,
+ tlpUpsInputLowTransferVoltageUpperBound Unsigned32,
+ tlpUpsInputHighTransferVoltage Unsigned32,
+ tlpUpsInputHighTransferVoltageLowerBound Unsigned32,
+ tlpUpsInputHighTransferVoltageUpperBound Unsigned32,
+ tlpUpsInputWattHours Unsigned32,
+ tlpUpsInputLowTransferVoltageResetTolerance Unsigned32,
+ tlpUpsInputHighTransferVoltageResetTolerance Unsigned32 }
+
+tlpUpsInputLineBads OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A count of the number of times the input entered an out-of-tolerance
+ condition as defined by the manufacturer. This count is incremented
+ by one each time the input transitions from zero out-of-tolerance
+ lines to one or more input lines out-of-tolerance. This value is not
+ supported on all units. If the ups does not support this value, then
+ the agent reports ERROR_NO_SUCH_NAME."
+ ::= { tlpUpsInputEntry 1 }
+
+tlpUpsInputNominalVoltage OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The nominal value of the input line voltage. This value may not
+ be supported on all models. If not supported, this value will return
+ ERROR_NO_SUCH_NAME."
+ ::= { tlpUpsInputEntry 2 }
+
+tlpUpsInputNominalFrequency OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The nominal value of the input line frequency. This value may not
+ be supported on all models. If not supported, this value will return
+ ERROR_NO_SUCH_NAME."
+ ::= { tlpUpsInputEntry 3 }
+
+tlpUpsInputLowTransferVoltage OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Volts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The minimum line voltage allowed before the ups system transfers to
+ battery backup."
+ ::= { tlpUpsInputEntry 4 }
+
+tlpUpsInputLowTransferVoltageLowerBound OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Volts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The lower boundary value of tlpUpsInputLowTransferVoltage as dictated
+ by the hardware of the unit."
+ ::= { tlpUpsInputEntry 5 }
+
+tlpUpsInputLowTransferVoltageUpperBound OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Volts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The upper boundary value of tlpUpsInputLowTransferVoltage as dictated
+ by the hardware of the unit."
+ ::= { tlpUpsInputEntry 6 }
+
+tlpUpsInputHighTransferVoltage OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Volts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The maximum line voltage allowed before the ups system transfers to
+ battery backup."
+ ::= { tlpUpsInputEntry 7 }
+
+tlpUpsInputHighTransferVoltageLowerBound OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Volts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The lower boundary value of tlpUpsInputHighTransferVoltage as dictated
+ by the hardware of the unit."
+ ::= { tlpUpsInputEntry 8 }
+
+tlpUpsInputHighTransferVoltageUpperBound OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Volts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The upper boundary value of tlpUpsInputHighTransferVoltage as dictated
+ by the hardware of the unit."
+ ::= { tlpUpsInputEntry 9 }
+
+tlpUpsInputWattHours OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "WH"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of watt hours of energy utilized in the past 24 hours. Use
+ tlpUpsControlResetWattHours to reset the watt hours calculation algorithm."
+ ::= { tlpUpsInputEntry 10 }
+
+tlpUpsInputLowTransferVoltageResetTolerance OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "Volts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "If a unit is transferred to battery backup due to under-voltage, the
+ line voltage has to rise above this value from tlpUpsConfigLowVoltageTransfer,
+ before the unit switched back to the AC input."
+ ::= { tlpUpsInputEntry 11 }
+
+tlpUpsInputHighTransferVoltageResetTolerance OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "Volts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "If an input transferred to battery backup due to over-voltage, the line voltage
+ on the input source has to fall below this value from tlpUpsConfigHighVoltageTransfer,
+ before the unit switched back to the AC input."
+ ::= { tlpUpsInputEntry 12 }
+
+tlpUpsInputPhaseTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpUpsInputPhaseEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The input phase details of each ups in the device table. This is
+ a sparse dependent table, and will contain the number of entries
+ based upon the number of upss managed by the agent as reported
+ by tlpUpsIdentNumUps and tlpUpsIdentNumPhases."
+ ::= { tlpUpsInput 2 }
+
+tlpUpsInputPhaseEntry OBJECT-TYPE
+ SYNTAX TlpUpsInputPhaseEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing information applicable to a particular
+ input phase managed by this agent."
+ INDEX { tlpDeviceIndex, tlpUpsInputPhaseIndex }
+ ::= { tlpUpsInputPhaseTable 1 }
+
+TlpUpsInputPhaseEntry ::= SEQUENCE {
+ tlpUpsInputPhaseIndex Unsigned32,
+ tlpUpsInputPhaseFrequency Unsigned32,
+ tlpUpsInputPhaseVoltage Unsigned32,
+ tlpUpsInputPhaseVoltageMin Unsigned32,
+ tlpUpsInputPhaseVoltageMax Unsigned32,
+ tlpUpsInputPhaseCurrent Unsigned32,
+ tlpUpsInputPhasePower Unsigned32 }
+
+tlpUpsInputPhaseIndex OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The table row index for the ups input phase."
+ ::= { tlpUpsInputPhaseEntry 1 }
+
+tlpUpsInputPhaseFrequency OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Hertz"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The present input frequency for a given input line."
+ ::= { tlpUpsInputPhaseEntry 2 }
+
+tlpUpsInputPhaseVoltage OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Volts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The magnitude of the present input voltage for a given input line."
+ ::= { tlpUpsInputPhaseEntry 3 }
+
+tlpUpsInputPhaseVoltageMin OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Volts"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The minimum input voltage value since the last reset of this
+ value for a given input line. If any value is written to either
+ tlpUpsInputVoltageMin or tlpUpsInputVoltageMax, both will be reset to
+ their appropriate minimum and maximum values."
+ ::= { tlpUpsInputPhaseEntry 4 }
+
+tlpUpsInputPhaseVoltageMax OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Volts"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The maximum input voltage value since the last reset of this
+ value for a given input line. If any value is written to either
+ tlpUpsInputVoltageMin or tlpUpsInputVoltageMax, both will be reset to
+ their appropriate minimum and maximum values."
+ ::= { tlpUpsInputPhaseEntry 5 }
+
+tlpUpsInputPhaseCurrent OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.01 Amps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The magnitude of the present input current."
+ ::= { tlpUpsInputPhaseEntry 6 }
+
+tlpUpsInputPhasePower OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "Watts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The magnitude of the present input true power."
+ ::= { tlpUpsInputPhaseEntry 7 }
+
+tlpUpsOutputTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpUpsOutputEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The output details of each ups in the device table. This is a sparse
+ dependent table, and will contain the number of entries based upon the
+ number of upss managed by the agent as reported by tlpUpsIdentNumUps."
+ ::= { tlpUpsOutput 1 }
+
+tlpUpsOutputEntry OBJECT-TYPE
+ SYNTAX TlpUpsOutputEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing information applicable to a particular
+ output line managed by this agent."
+ INDEX { tlpDeviceIndex }
+ ::= { tlpUpsOutputTable 1 }
+
+TlpUpsOutputEntry ::= SEQUENCE {
+ tlpUpsOutputSource INTEGER,
+ tlpUpsOutputNominalVoltage Unsigned32,
+ tlpUpsOutputFrequency Unsigned32,
+ tlpUpsOutputVARating Unsigned32,
+ tlpUpsOutputPowerFactor Unsigned32 }
+
+tlpUpsOutputSource OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(0),
+ other(1),
+ none(2),
+ normal(3),
+ bypass(4),
+ battery(5),
+ boosting(6),
+ reducing(7),
+ second(8),
+ economy(9),
+ testing(10) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The present source of output power. The enumeration none(2)
+ indicates that there is no source of output power (and
+ therefore no output power), for example, the system has opened
+ the output breaker."
+ ::= { tlpUpsOutputEntry 1 }
+
+tlpUpsOutputNominalVoltage OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The nominal value of the output voltage. This value may not be
+ supported on all models. If not supported, the agent reports
+ ERROR_NO_SUCH_NAME."
+ ::= { tlpUpsOutputEntry 2 }
+
+tlpUpsOutputFrequency OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Hertz"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The present output frequency. The output frequency on most ups
+ devices is common across all output lines. Some ups devices, however,
+ maintain the output frequency per each line. If a common frequency is
+ supported by the ups, then this frequency will contain the common
+ frequency value. If not supported, the agent reports ERROR_NO_SUCH_NAME."
+ ::= { tlpUpsOutputEntry 3 }
+
+tlpUpsOutputVARating OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "VA"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The VA Rating of the ups. This value may not be
+ supported on all models. If not supported, the agent reports
+ ERROR_NO_SUCH_NAME."
+ ::= { tlpUpsOutputEntry 4 }
+
+tlpUpsOutputPowerFactor OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "percent"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The percentage of output power factor."
+ ::= { tlpUpsOutputEntry 5 }
+
+tlpUpsOutputLineTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpUpsOutputLineEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The output line details of each ups in the device table. This is
+ a sparse dependent table, and will contain the number of entries
+ based upon the number of upss managed by the agent as reported
+ by tlpUpsIdentNumUps."
+ ::= { tlpUpsOutput 2 }
+
+tlpUpsOutputLineEntry OBJECT-TYPE
+ SYNTAX TlpUpsOutputLineEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing information applicable to a particular
+ output line managed by this agent."
+ INDEX { tlpDeviceIndex, tlpUpsOutputLineIndex }
+ ::= { tlpUpsOutputLineTable 1 }
+
+TlpUpsOutputLineEntry ::= SEQUENCE {
+ tlpUpsOutputLineIndex Unsigned32,
+ tlpUpsOutputLineVoltage Unsigned32,
+ tlpUpsOutputLineCurrent Unsigned32,
+ tlpUpsOutputLinePower Unsigned32,
+ tlpUpsOutputLinePercentLoad INTEGER,
+ tlpUpsOutputLineFrequency Unsigned32,
+ tlpUpsOutputLineApparentPower Unsigned32 }
+
+tlpUpsOutputLineIndex OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The table row index for the ups output line."
+ ::= { tlpUpsOutputLineEntry 1 }
+
+tlpUpsOutputLineVoltage OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Volts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The magnitude of the present output voltage for a given output line."
+ ::= { tlpUpsOutputLineEntry 2 }
+
+tlpUpsOutputLineCurrent OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.01 Amps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The output current, in hundredths of amps, for a given line. The actual
+ precision of this value, whether a whole number, tenths or hundredths, is
+ returned by tlpUpsDeviceOutputCurrentPrecision."
+ ::= { tlpUpsOutputLineEntry 3 }
+
+tlpUpsOutputLinePower OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "Watts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The present output true power."
+ ::= { tlpUpsOutputLineEntry 4 }
+
+tlpUpsOutputLinePercentLoad OBJECT-TYPE
+ SYNTAX INTEGER (0..200)
+ UNITS "percent"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The percentage of the UPS power capacity presently being used on
+ this output line, i.e., the greater of the percent load of true
+ power capacity and the percent load of VA."
+ ::= { tlpUpsOutputLineEntry 5 }
+
+tlpUpsOutputLineFrequency OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Hertz"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The present output frequency on this output line. The output frequency on
+ most ups devices is common across all output lines. Some ups devices, however,
+ maintain the output frequency per each line. If a per line frequency is
+ supported by the ups, then this frequency value will reports the value of this
+ line. If not supported, the agent reports ERROR_NO_SUCH_NAME."
+ ::= { tlpUpsOutputLineEntry 6 }
+
+tlpUpsOutputLineApparentPower OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "Watts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The present output apparent power."
+ ::= { tlpUpsOutputLineEntry 9 }
+
+tlpUpsBypassTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpUpsBypassEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The bypass details of each ups in the device table. This is a sparse
+ dependent table, and will contain the number of entries based upon the
+ number of upss managed by the agent as reported by tlpUpsIdentNumUps."
+ ::= { tlpUpsBypass 1 }
+
+tlpUpsBypassEntry OBJECT-TYPE
+ SYNTAX TlpUpsBypassEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing information applicable to all input lines per
+ each ups managed by this agent."
+ INDEX { tlpDeviceIndex }
+ ::= { tlpUpsBypassTable 1 }
+
+TlpUpsBypassEntry ::= SEQUENCE {
+ tlpUpsBypassFrequency Unsigned32 }
+
+tlpUpsBypassFrequency OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Hertz"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The present bypass frequency."
+ ::= { tlpUpsBypassEntry 1 }
+
+tlpUpsBypassLineTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpUpsBypassLineEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The bypass line details of each ups in the device table. This is
+ a sparse dependent table, and will contain the number of entries
+ based upon the number of upss managed by the agent as reported
+ by tlpUpsIdentNumUps."
+ ::= { tlpUpsBypass 2 }
+
+tlpUpsBypassLineEntry OBJECT-TYPE
+ SYNTAX TlpUpsBypassLineEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing information applicable to a particular
+ bypass line managed by this agent."
+ INDEX { tlpDeviceIndex, tlpUpsBypassLineIndex }
+ ::= { tlpUpsBypassLineTable 1 }
+
+TlpUpsBypassLineEntry ::= SEQUENCE {
+ tlpUpsBypassLineIndex Unsigned32,
+ tlpUpsBypassLineVoltage Unsigned32,
+ tlpUpsBypassLineCurrent Unsigned32,
+ tlpUpsBypassLinePower Unsigned32 }
+
+tlpUpsBypassLineIndex OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The bypass line identifier."
+ ::= { tlpUpsBypassLineEntry 1 }
+
+tlpUpsBypassLineVoltage OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Volts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The present bypass voltage."
+ ::= { tlpUpsBypassLineEntry 2 }
+
+tlpUpsBypassLineCurrent OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Amps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The present bypass current."
+ ::= { tlpUpsBypassLineEntry 3 }
+
+tlpUpsBypassLinePower OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "Watts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The present true power conveyed by the bypass."
+ ::= { tlpUpsBypassLineEntry 4 }
+
+tlpUpsOutletTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpUpsOutletEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The details of each ups outlet in the device table. This is
+ a sparse dependent table, and will contain the number of entries
+ based upon the number of upss managed by the agent as reported
+ by tlpUpsIdentNumUps."
+ ::= { tlpUpsOutlet 1 }
+
+tlpUpsOutletEntry OBJECT-TYPE
+ SYNTAX TlpUpsOutletEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing information applicable to a particular outlet
+ managed by this agent."
+ INDEX { tlpDeviceIndex, tlpUpsOutletIndex }
+ ::= { tlpUpsOutletTable 1 }
+
+TlpUpsOutletEntry ::= SEQUENCE {
+ tlpUpsOutletIndex Unsigned32,
+ tlpUpsOutletName DisplayString,
+ tlpUpsOutletDescription DisplayString,
+ tlpUpsOutletState INTEGER,
+ tlpUpsOutletControllable TruthValue,
+ tlpUpsOutletCommand INTEGER,
+ tlpUpsOutletVoltage Unsigned32,
+ tlpUpsOutletCurrent Unsigned32,
+ tlpUpsOutletPower Unsigned32,
+ tlpUpsOutletRampAction INTEGER,
+ tlpUpsOutletRampDelay Integer32,
+ tlpUpsOutletShedAction INTEGER,
+ tlpUpsOutletShedDelay Integer32,
+ tlpUpsOutletGroup Integer32 }
+
+tlpUpsOutletIndex OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The table row index for the ups outlet."
+ ::= { tlpUpsOutletEntry 1 }
+
+tlpUpsOutletName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A user-definable string identifying the name of the outlet."
+ ::= { tlpUpsOutletEntry 2 }
+
+tlpUpsOutletDescription OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A user-definable string identifying the device(s) connected to
+ the given outlet."
+ ::= { tlpUpsOutletEntry 3 }
+
+tlpUpsOutletState OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(0),
+ off(1),
+ on(2) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current state of the outlet."
+ ::= { tlpUpsOutletEntry 4 }
+
+tlpUpsOutletControllable OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Denotes whether this outlet is controllable."
+ ::= { tlpUpsOutletEntry 5 }
+
+tlpUpsOutletCommand OBJECT-TYPE
+ SYNTAX INTEGER {
+ idle(0),
+ turnOff(1),
+ turnOn(2),
+ cycle(3) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Reading this value will always return 0. Setting this value
+ to turnOff(1) will turn off the outlet. Setting this value
+ to turnOn(2) will turn on the outlet. Setting this value to
+ cycle(3) will turn the outlet off, then turn it back on."
+ ::= { tlpUpsOutletEntry 6 }
+
+tlpUpsOutletVoltage OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Volts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The magnitude of the present output voltage for a given outlet.
+ If the voltage measurement is not supported for an individual
+ receptacle regardless whether device-wide or just for this
+ receptacle, then this value will always return ERROR_NO_SUCH_NAME.
+ Device-wide support for receptacle voltage measurements is denoted
+ by tlpUpsSupportsOutletVoltage."
+ ::= { tlpUpsOutletEntry 7 }
+
+tlpUpsOutletCurrent OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.01 Amps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The present output current, in hundredths of amps, of a given outlet.
+ If the current measurement is not supported for an individual
+ receptacle regardless whether device-wide or just for this
+ receptacle, then this value will always return ERROR_NO_SUCH_NAME.
+ Device-wide support for receptacle current measurements is denoted
+ by tlpUpsSupportsCurrentPower."
+ ::= { tlpUpsOutletEntry 8 }
+
+tlpUpsOutletPower OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "Watts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The output power of a given outlet. If the power measurement is
+ not supported for an individual receptacle regardless whether
+ device-wide or just for this receptacle, then this value will
+ always return ERROR_NO_SUCH_NAME. Device-wide support for receptacle
+ power measurements is denoted by tlpUpsSupportsCurrentPower."
+ ::= { tlpUpsOutletEntry 9 }
+
+tlpUpsOutletRampAction OBJECT-TYPE
+ SYNTAX INTEGER {
+ remainOff(0),
+ turnOnAfterDelay(1) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The ramp action to take on a given outlet when powering on the
+ device. If this receptacle is not controllable, as denoted by
+ tlpUpsOutletControllable, then this value will always return
+ ERROR_NO_SUCH_NAME."
+ ::= { tlpUpsOutletEntry 10 }
+
+tlpUpsOutletRampDelay OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "seconds"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The number of seconds to delay before powering on the given outlet.
+ If this receptacle is not controllable, as denoted by
+ tlpUpsOutletControllable, then this value will always return
+ ERROR_NO_SUCH_NAME."
+ ::= { tlpUpsOutletEntry 11 }
+
+tlpUpsOutletShedAction OBJECT-TYPE
+ SYNTAX INTEGER {
+ remainOn(0),
+ turnOffAfterDelay(1) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The shed action to take on a given outlet when powering off the
+ device. If this receptacle is not controllable, as denoted by
+ tlpUpsOutletControllable, then this value will always return
+ ERROR_NO_SUCH_NAME."
+ ::= { tlpUpsOutletEntry 12 }
+
+tlpUpsOutletShedDelay OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "seconds"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The number of seconds to delay before powering off the given outlet.
+ If this receptacle is not controllable, as denoted by
+ tlpUpsOutletControllable, then this value will always return
+ ERROR_NO_SUCH_NAME."
+ ::= { tlpUpsOutletEntry 13 }
+
+tlpUpsOutletGroup OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The tlpUpsOutletGroupIndex group index of the respective group to
+ which the given outlet is assigned, or zero (0) if the given
+ outlet is not grouped."
+ ::= { tlpUpsOutletEntry 14 }
+
+tlpUpsOutletGroupTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpUpsOutletGroupEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The receptacle grouping details of each ups in device table.
+ This is a sparse dependent table, and will contain the number
+ of entries based upon the value of tlpUpsIdentNumOutletGroups per
+ each device."
+ ::= { tlpUpsOutlet 2 }
+
+tlpUpsOutletGroupEntry OBJECT-TYPE
+ SYNTAX TlpUpsOutletGroupEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing information applicable to a particular outlet
+ group managed by this agent."
+ INDEX { tlpDeviceIndex, tlpUpsOutletGroupIndex }
+ ::= { tlpUpsOutletGroupTable 1 }
+
+TlpUpsOutletGroupEntry ::= SEQUENCE {
+ tlpUpsOutletGroupIndex Unsigned32,
+ tlpUpsOutletGroupRowStatus RowStatus,
+ tlpUpsOutletGroupName DisplayString,
+ tlpUpsOutletGroupDescription DisplayString,
+ tlpUpsOutletGroupState INTEGER,
+ tlpUpsOutletGroupCommand INTEGER }
+
+tlpUpsOutletGroupIndex OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The table row index for the ups outlet group."
+ ::= { tlpUpsOutletGroupEntry 1 }
+
+tlpUpsOutletGroupRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Row status for the tlpUpsOutletGroupTable"
+ ::= { tlpUpsOutletGroupEntry 2 }
+
+tlpUpsOutletGroupName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The name of this outlet group."
+ ::= { tlpUpsOutletGroupEntry 3 }
+
+tlpUpsOutletGroupDescription OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A description for this outlet group."
+ ::= { tlpUpsOutletGroupEntry 4 }
+
+tlpUpsOutletGroupState OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(0),
+ off(1),
+ on(2),
+ mixed(3) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current state of the outlet group. This value will report
+ off(1) if all outlets in the group are off, on(2) if all outlets
+ in the group are on, mixed(3) if some outlets in the group are
+ off and others are on, or unknown(0) if the state of the outlets
+ cannot be determined."
+ ::= { tlpUpsOutletGroupEntry 5 }
+
+tlpUpsOutletGroupCommand OBJECT-TYPE
+ SYNTAX INTEGER {
+ idle(0),
+ turnOff(1),
+ turnOn(2),
+ cycle(3) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Reading this value will always return 0. Setting this value to
+ turnOff(1) will turn off every outlet associated with the group.
+ Setting this value to turnOn(2) will turn on every outlet associated
+ with the group. Setting this value to cycle(3) will turn off every
+ outlet associated with the group, then turn each outlet back on."
+ ::= { tlpUpsOutletGroupEntry 6 }
+
+tlpUpsWatchdogTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpUpsWatchdogEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The watchdog details of each ups in device table. This is a
+ sparse dependent table, and will contain some subset of devices
+ that are upss."
+ ::= { tlpUpsWatchdog 1 }
+
+tlpUpsWatchdogEntry OBJECT-TYPE
+ SYNTAX TlpUpsWatchdogEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing watchdog details for a particular ups."
+ INDEX { tlpDeviceIndex }
+ ::= { tlpUpsWatchdogTable 1 }
+
+TlpUpsWatchdogEntry ::= SEQUENCE {
+ tlpUpsWatchdogSupported TruthValue,
+ tlpUpsWatchdogSecsBeforeReboot Unsigned32 }
+
+tlpUpsWatchdogSupported OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates whether or not this ups supports a watchdog reboot."
+ ::= { tlpUpsWatchdogEntry 1 }
+
+tlpUpsWatchdogSecsBeforeReboot OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The maximum number of seconds that can expire between polls that
+ the engine makes to the ups for data. If this time runs out, then
+ the ups will cycle its outputs. Set this to zero to turns disable
+ this feature."
+ ::= { tlpUpsWatchdogEntry 2 }
+
+tlpUpsFanTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpUpsFanEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The fan speed of each ups in the device table. This is a sparse
+ dependent table, and will contain the number of entries based upon the
+ number of upss managed by the agent as reported by tlpUpsIdentNumFans."
+ ::= { tlpUpsFan 1 }
+
+tlpUpsFanEntry OBJECT-TYPE
+ SYNTAX TlpUpsFanEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing information applicable to a particular fan
+ managed by this agent."
+ INDEX { tlpDeviceIndex, tlpUpsFanIndex }
+ ::= { tlpUpsFanTable 1 }
+
+TlpUpsFanEntry ::= SEQUENCE {
+ tlpUpsFanIndex Unsigned32,
+ tlpUpsFanSpeed Unsigned32 }
+
+tlpUpsFanIndex OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The table row index for the ups fan speed."
+ ::= { tlpUpsFanEntry 1 }
+
+tlpUpsFanSpeed OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "RPM"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The fan speed in rotations per minute."
+ ::= { tlpUpsFanEntry 2 }
+
+tlpUpsHeatsinkTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpUpsHeatsinkEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of ups heatsink thermistor table entries. The number of entries
+ is given by the value of tlpUpsIdentNumHeatsinks."
+ ::= { tlpUpsHeatsink 1 }
+
+tlpUpsHeatsinkEntry OBJECT-TYPE
+ SYNTAX TlpUpsHeatsinkEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing information applicable to a particular heatsink
+ managed by this agent."
+ INDEX { tlpDeviceIndex, tlpUpsHeatsinkIndex }
+ ::= { tlpUpsHeatsinkTable 1 }
+
+TlpUpsHeatsinkEntry ::= SEQUENCE {
+ tlpUpsHeatsinkIndex Unsigned32,
+ tlpUpsHeatsinkTemperatureC Integer32,
+ tlpUpsHeatsinkTemperatureF Integer32 }
+
+tlpUpsHeatsinkIndex OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The table row index for the ups heatsink."
+ ::= { tlpUpsHeatsinkEntry 1 }
+
+tlpUpsHeatsinkTemperatureC OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 degrees Celsius"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The temperature at the heatsink thermistor in tenths degrees Celsius.
+ Heatsink temperature measurements are not supported on all models. If
+ not supported, this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpUpsHeatsinkEntry 2 }
+
+tlpUpsHeatsinkTemperatureF OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 degrees Fahrenheit"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The temperature at the heatsink thermistor in tenths degrees Fahrenheit.
+ Heatsink temperature measurements are not supported on all models. If
+ not supported, this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpUpsHeatsinkEntry 3 }
+
+tlpUpsInputContactTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpUpsInputContactEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The input contact details of each ups in the device table. The number of entries
+ is given by the value of tlpUpsIdentNumInputContacts."
+ ::= { tlpUpsInputContact 1 }
+
+tlpUpsInputContactEntry OBJECT-TYPE
+ SYNTAX TlpUpsInputContactEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing input contact details for a particular ups."
+ INDEX { tlpDeviceIndex, tlpUpsInputContactIndex }
+ ::= { tlpUpsInputContactTable 1 }
+
+TlpUpsInputContactEntry ::= SEQUENCE {
+ tlpUpsInputContactIndex Unsigned32,
+ tlpUpsInputContactInAlarm INTEGER }
+
+tlpUpsInputContactIndex OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The table row index for the ups input contact details."
+ ::= { tlpUpsInputContactEntry 1 }
+
+tlpUpsInputContactInAlarm OBJECT-TYPE
+ SYNTAX INTEGER {
+ notInAlarm(0),
+ inAlarm(1) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The alarm status of the input contact. Input contacts are not supported on
+ all models. If not supported, the agent reports ERROR_NO_SUCH_NAME."
+ ::= { tlpUpsInputContactEntry 2 }
+
+tlpUpsOutputContactTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpUpsOutputContactEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The output contact details of each ups in the device table. The number of entries
+ is given by the value of tlpUpsIdentNumOuputContacts."
+ ::= { tlpUpsOutputContact 1 }
+
+tlpUpsOutputContactEntry OBJECT-TYPE
+ SYNTAX TlpUpsOutputContactEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing output contact details for a particular ups."
+ INDEX { tlpDeviceIndex, tlpUpsOutputContactIndex }
+ ::= { tlpUpsOutputContactTable 1 }
+
+TlpUpsOutputContactEntry ::= SEQUENCE {
+ tlpUpsOutputContactIndex Unsigned32,
+ tlpUpsOutputContactInAlarm INTEGER }
+
+tlpUpsOutputContactIndex OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The table row index for the ups output contact details."
+ ::= { tlpUpsOutputContactEntry 1 }
+
+tlpUpsOutputContactInAlarm OBJECT-TYPE
+ SYNTAX INTEGER {
+ notInAlarm(0),
+ inAlarm(1) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The alarm status of the output contact. Output contacts are not supported on
+ all models. If not supported, the agent reports ERROR_NO_SUCH_NAME."
+ ::= { tlpUpsOutputContactEntry 2 }
+
+tlpUpsControlTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpUpsControlEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The actionable controls for each ups in device table. This is a
+ sparse dependent table, and will contain some subset of devices
+ that are upss."
+ ::= { tlpUpsControl 1 }
+
+tlpUpsControlEntry OBJECT-TYPE
+ SYNTAX TlpUpsControlEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing controls for a particular ups."
+ INDEX { tlpDeviceIndex }
+ ::= { tlpUpsControlTable 1 }
+
+TlpUpsControlEntry ::= SEQUENCE {
+ tlpUpsControlSelfTest TruthValue,
+ tlpUpsControlRamp TruthValue,
+ tlpUpsControlShed TruthValue,
+ tlpUpsControlUpsOn TruthValue,
+ tlpUpsControlUpsOff TruthValue,
+ tlpUpsControlUpsReboot TruthValue,
+ tlpUpsControlBypass INTEGER,
+ tlpUpsControlResetWattHours TruthValue,
+ tlpUpsControlCancelSelfTest TruthValue,
+ tlpUpsControlResetAllParameters TruthValue }
+
+tlpUpsControlSelfTest OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Set to TRUE to initiate a self test on the ups."
+ ::= { tlpUpsControlEntry 1 }
+
+tlpUpsControlRamp OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Set to TRUE to initiate the pre-designated ramp
+ sequence on the ups."
+ ::= { tlpUpsControlEntry 2 }
+
+tlpUpsControlShed OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Set to TRUE to initiate the pre-designated shed
+ sequence on the ups."
+ ::= { tlpUpsControlEntry 3 }
+
+tlpUpsControlUpsOn OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Set to TRUE to turn the ups on."
+ ::= { tlpUpsControlEntry 4 }
+
+tlpUpsControlUpsOff OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Set to TRUE to turn the ups off."
+ ::= { tlpUpsControlEntry 5 }
+
+tlpUpsControlUpsReboot OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Set to TRUE to reboot the ups."
+ ::= { tlpUpsControlEntry 6 }
+
+tlpUpsControlBypass OBJECT-TYPE
+ SYNTAX INTEGER {
+ disable(0),
+ enable(1) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This switches the ups in and out of bypass mode. This value returns
+ the current bypass mode: disable(0) if the ups is not in bypass mode,
+ enable(1) if the ups is in bypass mode. Set to disable(0) to exit
+ bypass mode, or enable(1) to enter bypass mode. If switching bypass
+ mode is not supported, this value will return ERROR_NO_SUCH_NAME."
+ ::= { tlpUpsControlEntry 7 }
+
+tlpUpsControlResetWattHours OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Set to TRUE to reset the tlpUpsInputWattHours calculation algorithm."
+ ::= { tlpUpsControlEntry 8 }
+
+tlpUpsControlCancelSelfTest OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Set to TRUE to cancel the self test in progress."
+ ::= { tlpUpsControlEntry 9 }
+
+tlpUpsControlResetAllParameters OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Set to TRUE to reset all configuration settings to the default values."
+ ::= { tlpUpsControlEntry 10 }
+
+tlpUpsConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpUpsConfigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The configuration details of each ups in the device table. This is
+ a sparse dependent table, and will contain the number of entries
+ based upon the number of upss managed by the agent as reported by
+ tlpUpsIdentNumUps."
+ ::= { tlpUpsConfig 1 }
+
+tlpUpsConfigEntry OBJECT-TYPE
+ SYNTAX TlpUpsConfigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing information applicable to all input lines per
+ each ups managed by this agent."
+ INDEX { tlpDeviceIndex }
+ ::= { tlpUpsConfigTable 1 }
+
+TlpUpsConfigEntry ::= SEQUENCE {
+ tlpUpsConfigInputVoltage Unsigned32,
+ tlpUpsConfigInputFrequency Unsigned32,
+ tlpUpsConfigOutputVoltage Unsigned32,
+ tlpUpsConfigOutputFrequency Unsigned32,
+ tlpUpsConfigAudibleStatus INTEGER,
+ tlpUpsConfigAutoBatteryTest INTEGER,
+ tlpUpsConfigAutoRestartAfterShutdown INTEGER,
+ tlpUpsConfigAutoRampOnTransition INTEGER,
+ tlpUpsConfigAutoShedOnTransition INTEGER,
+ tlpUpsConfigBypassLowerLimitPercent INTEGER,
+ tlpUpsConfigBypassUpperLimitPercent INTEGER,
+ tlpUpsConfigBypassLowerLimitVoltage Unsigned32,
+ tlpUpsConfigBypassUpperLimitVoltage Unsigned32,
+ tlpUpsConfigColdStart INTEGER,
+ tlpUpsConfigEconomicMode INTEGER,
+ tlpUpsConfigFaultAction INTEGER,
+ tlpUpsConfigOffMode INTEGER,
+ tlpUpsConfigLineSensitivity INTEGER,
+ tlpUpsConfigLineQualifyTime Unsigned32,
+ tlpUpsConfigACPowerSenseType INTEGER }
+
+tlpUpsConfigInputVoltage OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "Volts"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The nominal value of the input line voltage. This value may not
+ be supported on all models. If not supported, this value will return
+ ERROR_NO_SUCH_NAME. This value may not be writable on all models. If
+ not writable, the value will be rejected and an appropriate error
+ message will be returned."
+ ::= { tlpUpsConfigEntry 1 }
+
+tlpUpsConfigInputFrequency OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Hertz"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The nominal input frequency. On those systems which support read-write
+ access to this object, if there is an attempt to set this variable to a
+ value that is not supported, the request must be rejected and the agent
+ shall respond with an appropriate error message, i.e., badValue for
+ SNMPv1, or inconsistentValue for SNMPv2."
+ ::= { tlpUpsConfigEntry 2 }
+
+tlpUpsConfigOutputVoltage OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "Volts"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The nominal value of the output voltage. This value may not be
+ supported on all models. If not supported, the agent reports
+ ERROR_NO_SUCH_NAME. This value may not be writable on all models. If
+ not writable, the value will be rejected and an appropriate error
+ message will be returned."
+ ::= { tlpUpsConfigEntry 3 }
+
+tlpUpsConfigOutputFrequency OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Hertz"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The nominal output frequency. On those systems which support read-write
+ access to this object, if there is an attempt to set this variable to a
+ value that is not supported, the request will be rejected and the agent
+ will respond with an appropriate error message."
+ ::= { tlpUpsConfigEntry 4 }
+
+tlpUpsConfigAudibleStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(1),
+ enabled(2),
+ muted(3) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The requested state of the audible alarm. When in the disabled state,
+ the audible alarm should never sound. The enabled state is self-
+ describing. Setting this object to muted(3) when the audible alarm is
+ sounding shall temporarily silence the alarm. It will remain muted until
+ it would normally stop sounding and the value returned for read operations
+ during this period shall equal muted(3). At the end of this period, the
+ value shall revert to enabled(2). Writes of the value muted(3) when the
+ audible alarm is not sounding shall be accepted but otherwise shall have no
+ effect."
+ ::= { tlpUpsConfigEntry 5 }
+
+tlpUpsConfigAutoBatteryTest OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ biweekly(1),
+ monthly(2),
+ quarterly(3),
+ semiannually(4) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "When disabled(0), the ups will not perform an automatic battery selftest.
+ When set to another value, the ups will perform an automatic selftest in
+ the approximate period defined by each respective enumerated value. This
+ feature is generally not recommended."
+ ::= { tlpUpsConfigEntry 6 }
+
+tlpUpsConfigAutoRestartAfterShutdown OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "When enabled(1), the ups should autorestart after a shutdown from battery
+ mode if valid AC is applied. When disabled(0), the ups should not autorestart
+ when AC is restored and instead power up into standby mode."
+ ::= { tlpUpsConfigEntry 7 }
+
+tlpUpsConfigAutoRampOnTransition OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "When enabled(1), the ups should perform its preconfigured ramp sequence when
+ valid AC is restored while in battery mode. If this value is not supported by
+ the ups, then this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpUpsConfigEntry 8 }
+
+tlpUpsConfigAutoShedOnTransition OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "When enabled(1), the ups should perform its preconfigured shed sequence when
+ valid AC is lost causing the ups to enter battery mode. If this value is not
+ supported by the ups, then this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpUpsConfigEntry 9 }
+
+tlpUpsConfigBypassLowerLimitPercent OBJECT-TYPE
+ SYNTAX INTEGER (-20..-5)
+ UNITS "percent"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The lowest AC input voltage allowed to be output to the load while in bypass
+ mode. This setting is expressed as a percentage from nominal voltage. If this
+ value is not supported by the ups, then this value will always return
+ ERROR_NO_SUCH_NAME."
+ ::= { tlpUpsConfigEntry 10 }
+
+tlpUpsConfigBypassUpperLimitPercent OBJECT-TYPE
+ SYNTAX INTEGER (5..20)
+ UNITS "percent"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The highest AC input voltage allowed to be output to the load while in bypass
+ mode. This setting is expressed as a percentage from nominal voltage. If this
+ value is not supported by the ups, then this value will always return
+ ERROR_NO_SUCH_NAME."
+ ::= { tlpUpsConfigEntry 11 }
+
+tlpUpsConfigBypassLowerLimitVoltage OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "Volts"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The lowest AC input voltage allowed to be output to the load while in bypass
+ mode. If this value is not supported by the ups, then this value will always
+ return ERROR_NO_SUCH_NAME."
+ ::= { tlpUpsConfigEntry 12 }
+
+tlpUpsConfigBypassUpperLimitVoltage OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "Volts"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The highest AC input voltage allowed to be output to the load while in bypass
+ mode. If this value is not supported by the ups, then this value will always
+ return ERROR_NO_SUCH_NAME."
+ ::= { tlpUpsConfigEntry 13 }
+
+tlpUpsConfigColdStart OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This option enables or disables the ability to turn the ups on without AC
+ supplied. If this value is not supported by the ups, then this value will
+ always return ERROR_NO_SUCH_NAME."
+ ::= { tlpUpsConfigEntry 14 }
+
+tlpUpsConfigEconomicMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ online(0),
+ economy(1),
+ constant50Hz(2),
+ constant60Hz(3),
+ constantAuto(4),
+ autoAdaptive(5) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The configurable economic mode options for the ups. The online(0) mode is
+ the default configuration of most upss, which is synonymous as having the
+ economic mode disabled. The economy(1) mode is the typical configuration to
+ run in economy mode, which is synonymous as having the economic mode enabled.
+ Constant50Hz(2) is a power strategy, which fixes the output frequency at 50Hz.
+ Constant60Hz(3) is a power strategy, which fixes the output frequency at 60Hz.
+ ConstantAuto(4) regulates the output frequency at nominal input frequency.
+ AutoAdaptive(5) mode will cause the ups to automatically switch between
+ online(0), maximum quality, and economy(1), maximum efficiency, to improve
+ efficiency during stable utility periods and improve output regulation during
+ unstable utility periods. Not all values are supported by all upss. Most upss,
+ if supportive of economic mode, only supports online(0) and economy(1). If the
+ ups does not support economic mode, then this value will always return
+ ERROR_NO_SUCH_NAME."
+ ::= { tlpUpsConfigEntry 15 }
+
+tlpUpsConfigFaultAction OBJECT-TYPE
+ SYNTAX INTEGER {
+ bypass(0),
+ standby(1) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Determines the action to take if the output needs to be shut down due to a
+ fault condition, limited by the type of fault incurred. When configured for
+ bypass(0), the ups will go to bypass on a fault condition. When configured
+ for standby(1), the ups will go to standby mode on a fault condition. Either
+ configuration will be valid as long as AC input is within normal line voltage
+ and frequency limits when the fault condition occurs. If the line is outside
+ these limits, the ups will turn off. If this value is not supported by the ups,
+ then this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpUpsConfigEntry 16 }
+
+tlpUpsConfigOffMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ standby(0),
+ bypass(1) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This option governs what mode the ups should go into when AC input is
+ available, but the load is either off or not battery backed up. If this
+ setting is configured for bypass(1), the intention is that any time the ups
+ would normally go into standby mode, it would instead go into bypass mode. Note
+ that this setting does not dictate the mode for fault conditions, which is
+ governed by tlpUpsConfigFaultAction. If this value is not supported by the ups,
+ then this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpUpsConfigEntry 17 }
+
+tlpUpsConfigLineSensitivity OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal(0),
+ reduced(1),
+ fullyReduced(2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Adjusts the AC line voltage sensitivity setting. If this value is not supported
+ by the ups, then this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpUpsConfigEntry 18 }
+
+tlpUpsConfigLineQualifyTime OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "seconds"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The amount of time the ups monitors line power quality for stability before ac power
+ is restored. If there is an attempt to set this variable to a
+ value that is not supported, the request will be rejected and the agent
+ will respond with an appropriate error message."
+ ::= { tlpUpsConfigEntry 19 }
+
+tlpUpsConfigACPowerSenseType OBJECT-TYPE
+ SYNTAX INTEGER {
+ generator(1),
+ ups(2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This option enables configuration of ups AC power sensing to maximize ups
+ operation for standard line power AC and generator power applications.
+ If this value is not supported by the ups, then this value will always return
+ ERROR_NO_SUCH_NAME."
+ ::= { tlpUpsConfigEntry 20 }
+
+tlpUpsConfigAutoRestartTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpUpsConfigAutoRestartEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The configurable automatic restart options of each ups in device table.
+ This is a sparse dependent table, and will contain some subset of devices
+ that are upss. Not all options are available on all upss."
+ ::= { tlpUpsConfig 2 }
+
+tlpUpsConfigAutoRestartEntry OBJECT-TYPE
+ SYNTAX TlpUpsConfigAutoRestartEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing configurable automatic restart options for a particular
+ ups."
+ INDEX { tlpDeviceIndex }
+ ::= { tlpUpsConfigAutoRestartTable 1 }
+
+TlpUpsConfigAutoRestartEntry ::= SEQUENCE {
+ tlpUpsConfigAutoRestartInverterShutdown INTEGER,
+ tlpUpsConfigAutoRestartDelayedWakeup INTEGER,
+ tlpUpsConfigAutoRestartLowVoltageCutoff INTEGER,
+ tlpUpsConfigAutoRestartOverLoad INTEGER,
+ tlpUpsConfigAutoRestartOverTemperature INTEGER }
+
+tlpUpsConfigAutoRestartInverterShutdown OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "If enabled(1) and the ups is turned off from invert mode (via user
+ interaction), if line becomes valid, the ups will automatically go to line
+ mode. If disabled(0), the ups will turn back on and go to standby mode
+ instead."
+ ::= { tlpUpsConfigAutoRestartEntry 1 }
+
+tlpUpsConfigAutoRestartDelayedWakeup OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "If enabled(1) and power fails during a DelayBeforeStartup and line remains
+ invalid after the timeout expires, the ups will be set to turn back on
+ automatically. If disabled(0), the ups will turn back on and go to standby
+ mode instead."
+ ::= { tlpUpsConfigAutoRestartEntry 2 }
+
+tlpUpsConfigAutoRestartLowVoltageCutoff OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "If enabled(1) and the ups is turned off from invert mode (via low voltage
+ cutoff), if line becomes valid, the ups will automatically go to line mode.
+ If disabled(0), the ups will turn back on and go to standby mode instead."
+ ::= { tlpUpsConfigAutoRestartEntry 3 }
+
+tlpUpsConfigAutoRestartOverLoad OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "If enabled(1) and the ups is turned off from invert mode (via overload), if
+ line becomes valid, the ups will automatically go to line mode. If disabled(0),
+ the ups will turn back on and go to standby mode instead."
+ ::= { tlpUpsConfigAutoRestartEntry 4 }
+
+tlpUpsConfigAutoRestartOverTemperature OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "If enabled(1) and the ups is turned off from invert mode (via over temperature),
+ if line becomes valid, the ups will automatically go to line mode. If disabled(0),
+ the ups will turn back on and go to standby mode instead."
+ ::= { tlpUpsConfigAutoRestartEntry 5 }
+
+tlpUpsConfigThresholdTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpUpsConfigThresholdEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The configurable threshold options of each ups in device table. This
+ is a sparse dependent table, and will contain some subset of devices that
+ are upss. Not all options are available on all upss."
+ ::= { tlpUpsConfig 3 }
+
+tlpUpsConfigThresholdEntry OBJECT-TYPE
+ SYNTAX TlpUpsConfigThresholdEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing configurable threshold options for a particular ups."
+ INDEX { tlpDeviceIndex }
+ ::= { tlpUpsConfigThresholdTable 1 }
+
+TlpUpsConfigThresholdEntry ::= SEQUENCE {
+ tlpUpsConfigBatteryAgeThreshold Unsigned32,
+ tlpUpsConfigLowBatteryThreshold INTEGER,
+ tlpUpsConfigLowBatteryTime Unsigned32,
+ tlpUpsConfigOverLoadThreshold INTEGER }
+
+tlpUpsConfigBatteryAgeThreshold OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "months"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The number of months for a battery to be in service. The battery age alarm,
+ tlpUpsAlarmBatteryAgeAboveThreshold, is triggered when the current date
+ exceeds tlpUpsBatteryPackIdentInstallDate by tlpUpsConfigBatteryAgeThreshold
+ months."
+ ::= { tlpUpsConfigThresholdEntry 1 }
+
+tlpUpsConfigLowBatteryThreshold OBJECT-TYPE
+ SYNTAX INTEGER (5..95)
+ UNITS "percent"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This value denotes the percentage of battery capacity remaining warning
+ level. The low battery alarm, tlpUpsAlarmLowBattery, is triggered when
+ tlpUpsEstimatedChargeRemaining drops below this value."
+ ::= { tlpUpsConfigThresholdEntry 2 }
+
+tlpUpsConfigLowBatteryTime OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "seconds"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The value in seconds of tlpUpsEstimatedMinutesRemaining at which a lowBattery
+ condition is declared. For agents which support only discrete (discontinuous)
+ values, then the agent shall round up to the next supported value. If the
+ requested value is larger than the largest supported value, then the largest
+ supported value shall be selected."
+ ::= { tlpUpsConfigThresholdEntry 3 }
+
+tlpUpsConfigOverLoadThreshold OBJECT-TYPE
+ SYNTAX INTEGER (5..105)
+ UNITS "percent"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This value denotes the percentage of load at which the overload condition
+ occurs. The overload alarm, tlpUpsAlarmOutputOverload, is triggered when the
+ percentage of output load exceeds this value."
+ ::= { tlpUpsConfigThresholdEntry 4 }
+
+tlpUpsConfigVoltageTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpUpsConfigVoltageEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The voltage configuration details for each ups in device table. This
+ is a sparse dependent table, and will contain some subset of devices
+ that are upss. Not all options are available on all upss."
+ ::= { tlpUpsConfig 4 }
+
+tlpUpsConfigVoltageEntry OBJECT-TYPE
+ SYNTAX TlpUpsConfigVoltageEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing voltage configuration options for a particular ups."
+ INDEX { tlpDeviceIndex }
+ ::= { tlpUpsConfigVoltageTable 1 }
+
+TlpUpsConfigVoltageEntry ::= SEQUENCE {
+ tlpUpsConfigHighVoltageTransfer Unsigned32,
+ tlpUpsConfigHighVoltageResetTolerance Unsigned32,
+ tlpUpsConfigHighVoltageReset Unsigned32,
+ tlpUpsConfigLowVoltageTransfer Unsigned32,
+ tlpUpsConfigLowVoltageResetTolerance Unsigned32,
+ tlpUpsConfigLowVoltageReset Unsigned32 }
+
+tlpUpsConfigHighVoltageTransfer OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Volts"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The maximum line voltage allowed on the input source before the unit
+ disconnects the AC input connection."
+ ::= { tlpUpsConfigVoltageEntry 1 }
+
+tlpUpsConfigHighVoltageResetTolerance OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "Volts"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "If an input connection is disconnected due to over-voltage, the line voltage on the input source
+ has to fall below tlpUpsConfigHighVoltageTransfer less tlpUpsConfigHighVoltageTransferResetTolerance `
+ before the unit reconnects the AC input to input source."
+ ::= { tlpUpsConfigVoltageEntry 2 }
+
+tlpUpsConfigHighVoltageReset OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Volts"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "If an input connection is disconnected due to over-voltage, the line voltage on the input source
+ has to fall below tlpUpsConfigHighVoltageReset before the unit reconnects the AC input to input source."
+ ::= { tlpUpsConfigVoltageEntry 3 }
+
+tlpUpsConfigLowVoltageTransfer OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Volts"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The minimum line voltage allowed before the unit disconnects the AC input
+ connection."
+ ::= { tlpUpsConfigVoltageEntry 4 }
+
+tlpUpsConfigLowVoltageResetTolerance OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "Volts"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "If a unit is disconnected due to under-voltage or is not powered up yet, the line voltage
+ has to rise above tlpUpsConfigLowVoltageTransfer plus tlpUpsConfigLowVoltageTransferResetTolerance
+ before the unit reonnect the AC input to input source."
+ ::= { tlpUpsConfigVoltageEntry 5 }
+
+tlpUpsConfigLowVoltageReset OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Volts"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "If a unit is disconnected due to under-voltage or is not powered up yet, the line voltage
+ has to rise above tlpUpsConfigLowVoltageReset before the unit reonnect the AC input to input source."
+ ::= { tlpUpsConfigVoltageEntry 6 }
+
+tlpUpsConfigContact OBJECT IDENTIFIER::= { tlpUpsConfig 5 }
+
+tlpUpsConfigContactTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpUpsConfigContactEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The configuration options of each ups in device table. This
+ is a sparse dependent table, and will contain some subset of
+ devices that are upss. Not all options are available on all
+ upss."
+ ::= { tlpUpsConfigContact 1 }
+
+tlpUpsConfigContactEntry OBJECT-TYPE
+ SYNTAX TlpUpsConfigContactEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing contact configuration options for a particular ups."
+ INDEX { tlpDeviceIndex }
+ ::= { tlpUpsConfigContactTable 1 }
+
+TlpUpsConfigContactEntry ::= SEQUENCE {
+ tlpUpsConfigOutputContactBackupTimer INTEGER }
+
+tlpUpsConfigOutputContactBackupTimer OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This is the amount of runtime the UPS supports in battery mode before sending
+ a configured output contact notification. Output contacts are not supported on all
+ models. If not supported, this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpUpsConfigContactEntry 1 }
+
+tlpUpsConfigInputContactTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpUpsConfigInputContactEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The input contact details of each ups in device table. the number of entries is
+ given by tlpUpsIdentNumInputContacts. This is a sparse dependent table, and will
+ contain some subset of devices that are upss. Not all options are available on all
+ upss."
+ ::= { tlpUpsConfigContact 2 }
+
+tlpUpsConfigInputContactEntry OBJECT-TYPE
+ SYNTAX TlpUpsConfigInputContactEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing input contact details for a particular ups."
+ INDEX { tlpDeviceIndex, tlpUpsConfigInputContactIndex }
+ ::= { tlpUpsConfigInputContactTable 1 }
+
+TlpUpsConfigInputContactEntry ::= SEQUENCE {
+ tlpUpsConfigInputContactIndex Unsigned32,
+ tlpUpsConfigInputContactSetup INTEGER }
+
+tlpUpsConfigInputContactIndex OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The table row index for the ups input contact details."
+ ::= { tlpUpsConfigInputContactEntry 1 }
+
+tlpUpsConfigInputContactSetup OBJECT-TYPE
+ SYNTAX INTEGER {
+ userDefined(0),
+ externalAlarm(1),
+ externalBatteryAlarm(2),
+ externalFanFailed(3),
+ doorUnlock(4)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Input contact configuration options. Input contacts are not supported on
+ all models. If not supported, the agent reports ERROR_NO_SUCH_NAME."
+ ::= { tlpUpsConfigInputContactEntry 2 }
+
+tlpUpsConfigOutputContactTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpUpsConfigOutputContactEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Output contact details of each ups in device table. The number of entries is
+ given by tlpUpsIdentNumOutputContacts. This is a sparse dependent table, and
+ will contain some subset of devices that are upss. Not all options are available
+ on all upss."
+ ::= { tlpUpsConfigContact 3 }
+
+tlpUpsConfigOutputContactEntry OBJECT-TYPE
+ SYNTAX TlpUpsConfigOutputContactEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing output contact details for a particular ups."
+ INDEX { tlpDeviceIndex, tlpUpsConfigOutputContactIndex }
+ ::= { tlpUpsConfigOutputContactTable 1 }
+
+TlpUpsConfigOutputContactEntry ::= SEQUENCE {
+ tlpUpsConfigOutputContactIndex Unsigned32,
+ tlpUpsConfigOutputContactSetup INTEGER }
+
+tlpUpsConfigOutputContactIndex OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The table row index for the ups output contact details."
+ ::= { tlpUpsConfigOutputContactEntry 1 }
+
+tlpUpsConfigOutputContactSetup OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ onBattery(1),
+ batteryLow(2),
+ timer(3),
+ alarm(4),
+ fault(5),
+ outputOff(6) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Output contact configuration options. Output contacts are not supported on
+ all models. If not supported, the agent reports ERROR_NO_SUCH_NAME."
+ ::= { tlpUpsConfigOutputContactEntry 2 }
+
+-- pdu
+
+tlpPduIdentNumPdu OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of pdu devices that this agent is currently managing."
+ ::= { tlpPduIdent 1 }
+
+tlpPduIdentTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpPduIdentEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The identity details of each pdu in device table. This is a
+ sparse dependent table, and will contain some subset of devices
+ that are pdus."
+ ::= { tlpPduIdent 2 }
+
+tlpPduIdentEntry OBJECT-TYPE
+ SYNTAX TlpPduIdentEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing details for a particular pdu."
+ INDEX { tlpDeviceIndex }
+ ::= { tlpPduIdentTable 1 }
+
+TlpPduIdentEntry ::= SEQUENCE {
+ tlpPduIdentNumInputs Unsigned32,
+ tlpPduIdentNumOutputs Unsigned32,
+ tlpPduIdentNumPhases Unsigned32,
+ tlpPduIdentNumOutlets Unsigned32,
+ tlpPduIdentNumOutletGroups Unsigned32,
+ tlpPduIdentNumCircuits Unsigned32,
+ tlpPduIdentNumBreakers Unsigned32,
+ tlpPduIdentNumHeatsinks Unsigned32 }
+
+tlpPduIdentNumInputs OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of input lines supported by the pdu."
+ ::= { tlpPduIdentEntry 1 }
+
+tlpPduIdentNumOutputs OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of output lines supported by the pdu."
+ ::= { tlpPduIdentEntry 2 }
+
+tlpPduIdentNumPhases OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of phases supported by the pdu."
+ ::= { tlpPduIdentEntry 3 }
+
+tlpPduIdentNumOutlets OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of receptacles supported by the pdu."
+ ::= { tlpPduIdentEntry 4 }
+
+tlpPduIdentNumOutletGroups OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of receptacle groups supported by the pdu."
+ ::= { tlpPduIdentEntry 5 }
+
+tlpPduIdentNumCircuits OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of circuits supported by the pdu."
+ ::= { tlpPduIdentEntry 6 }
+
+tlpPduIdentNumBreakers OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of monitored bank breakers supported by the pdu.
+ If the pdu has breakers that are not monitored by the device,
+ the value of zero(0) will be returned."
+ ::= { tlpPduIdentEntry 7 }
+
+tlpPduIdentNumHeatsinks OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of heatsink thermistors supported by the pdu."
+ ::= { tlpPduIdentEntry 8 }
+
+tlpPduSupportsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpPduSupportsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The supported details of each pdu in device table. This is a
+ sparse dependent table, and will contain some subset of devices
+ that are pdus."
+ ::= { tlpPduIdent 3 }
+
+tlpPduSupportsEntry OBJECT-TYPE
+ SYNTAX TlpPduSupportsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing supported details for a particular pdu."
+ INDEX { tlpDeviceIndex }
+ ::= { tlpPduSupportsTable 1 }
+
+TlpPduSupportsEntry ::= SEQUENCE {
+ tlpPduSupportsEnergywise TruthValue,
+ tlpPduSupportsRampShed TruthValue,
+ tlpPduSupportsOutletGroup TruthValue,
+ tlpPduSupportsOutletCurrentPower TruthValue,
+ tlpPduSupportsOutletVoltage TruthValue }
+
+tlpPduSupportsEnergywise OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates whether the pdu supports Cisco EnergyWise."
+ ::= { tlpPduSupportsEntry 1 }
+
+tlpPduSupportsRampShed OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates whether the pdu supports ramping and shedding."
+ ::= { tlpPduSupportsEntry 2 }
+
+tlpPduSupportsOutletGroup OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates whether the pdu supports outlet groups."
+ ::= { tlpPduSupportsEntry 3 }
+
+tlpPduSupportsOutletCurrentPower OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates whether the pdu reports individual receptacle current
+ and power measurements. Devices that do not support individual
+ receptacle measurements will always return ERROR_NO_SUCH_NAME for
+ tlpPduOutletCurrent and tlpPduOutletPower."
+ ::= { tlpPduSupportsEntry 4 }
+
+tlpPduSupportsOutletVoltage OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates whether the pdu reports individual receptacle voltage
+ measurements. Devices that do not support individual receptacle
+ measurements will always return ERROR_NO_SUCH_NAME for
+ tlpPduOutletVoltage."
+ ::= { tlpPduSupportsEntry 5 }
+
+tlpPduDisplayTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpPduDisplayEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The display details of each pdu in device table. This is a
+ sparse dependent table, and will contain some subset of devices
+ that are pdus."
+ ::= { tlpPduIdent 4 }
+
+tlpPduDisplayEntry OBJECT-TYPE
+ SYNTAX TlpPduDisplayEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing display details for a particular pdu."
+ INDEX { tlpDeviceIndex }
+ ::= { tlpPduDisplayTable 1 }
+
+TlpPduDisplayEntry ::= SEQUENCE {
+ tlpPduDisplayScheme INTEGER,
+ tlpPduDisplayOrientation INTEGER,
+ tlpPduDisplayAutoScroll INTEGER,
+ tlpPduDisplayIntensity INTEGER,
+ tlpPduDisplayUnits INTEGER }
+
+tlpPduDisplayScheme OBJECT-TYPE
+ SYNTAX INTEGER {
+ schemeReverse(0),
+ schemeNormal(1) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Indicates the display scheme of the LED display. The value
+ schemeReverse(0) indicates the tricolor LED indicator uses an
+ alternate pattern. The value schemeNormal(1) indicates the
+ LED indicator uses the standard pattern. This value may not
+ be supported on all models. If not supported, the value will
+ always return schemeNormal(1)."
+ ::= { tlpPduDisplayEntry 1 }
+
+tlpPduDisplayOrientation OBJECT-TYPE
+ SYNTAX INTEGER {
+ displayNormal(0),
+ displayReverse(1) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Indicates the physical orientation of the LED display. The value
+ displayNormal(0) indicates the display is right-side-up (normal).
+ The value displayReverse(1) indicates the display is upside-down.
+ This value may not be supported on all models. If not supported,
+ the value will always return displayNormal(0)."
+ ::= { tlpPduDisplayEntry 2 }
+
+tlpPduDisplayAutoScroll OBJECT-TYPE
+ SYNTAX INTEGER {
+ scrollDisabled(0),
+ scrollEnabled(1) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Indicates whether the LED display automatically scrolls through
+ displaying status values."
+ ::= { tlpPduDisplayEntry 3 }
+
+tlpPduDisplayIntensity OBJECT-TYPE
+ SYNTAX INTEGER {
+ intensity25(1),
+ intensity50(2),
+ intensity75(3),
+ intensity100(4) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Indicates the intensity, as a percentage, of the LED display. The
+ value intensity100(4) indicates the display is at 100% intensity.
+ The other values indicate the display is at a lesser intensity based
+ upon the respective percentage denoted."
+ ::= { tlpPduDisplayEntry 4 }
+
+tlpPduDisplayUnits OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal(0),
+ metric(1) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Indicates the units of measurement displayed on the LED display.
+ The value normal(0) indicates that a temperature value, for example,
+ is displayed in degrees Fahrenheit. The value metric(1) indicates a
+ temperature value is displayed in degrees Celsius."
+ ::= { tlpPduDisplayEntry 5 }
+
+tlpPduDeviceTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpPduDeviceEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The device details of each pdu in device table. This is a
+ sparse dependent table, and will contain some subset of devices
+ that are pdus."
+ ::= { tlpPduDevice 1 }
+
+tlpPduDeviceEntry OBJECT-TYPE
+ SYNTAX TlpPduDeviceEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing device details for a particular pdu."
+ INDEX { tlpDeviceIndex }
+ ::= { tlpPduDeviceTable 1 }
+
+TlpPduDeviceEntry ::= SEQUENCE {
+ tlpPduDeviceMainLoadState INTEGER,
+ tlpPduDeviceMainLoadControllable TruthValue,
+ tlpPduDeviceMainLoadCommand INTEGER,
+ tlpPduDevicePowerOnDelay Integer32,
+ tlpPduDeviceTotalInputPowerRating Integer32,
+ tlpPduDeviceTemperatureC Integer32,
+ tlpPduDeviceTemperatureF Integer32,
+ tlpPduDevicePhaseImbalance INTEGER,
+ tlpPduDeviceOutputPowerTotal Unsigned32,
+ tlpPduDeviceAggregatePowerFactor Unsigned32,
+ tlpPduDeviceOutputCurrentPrecision INTEGER }
+
+tlpPduDeviceMainLoadState OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(0),
+ off(1),
+ on(2) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current state of the main output of the device."
+ ::= { tlpPduDeviceEntry 1 }
+
+tlpPduDeviceMainLoadControllable OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates whether or not the main output is controllable, and whether
+ the ups can be turned off and on."
+ ::= { tlpPduDeviceEntry 2 }
+
+tlpPduDeviceMainLoadCommand OBJECT-TYPE
+ SYNTAX INTEGER {
+ idle(0),
+ turnOff(1),
+ turnOn(2),
+ cycle(3) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Reading this value will always return 0. Setting this value to
+ turnOff(1) will turn off the main output of the ups. Setting this
+ value to turnOn(2) will turn on the main output of the ups. Setting
+ this value to cycle(3) will turn off the main output, then turn it
+ back on."
+ ::= { tlpPduDeviceEntry 3 }
+
+tlpPduDevicePowerOnDelay OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The configurable delay value, which sets the amount of additional
+ time a given device will wait before it connects to a valid AC
+ source. By default the delay value is set to 0. For devices with
+ multiple AC input sources, this delay only applies to the primary
+ input source."
+ ::= { tlpPduDeviceEntry 4 }
+
+tlpPduDeviceTotalInputPowerRating OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "Watts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total input power rating of all phases on the device. This
+ value may not be supported on all models. If not supported, this
+ value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpPduDeviceEntry 5 }
+
+tlpPduDeviceTemperatureC OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "degrees Celsius"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The ambient temperature at or near the PDU casing. Temperature
+ measurements are not supported on all models. If not supported,
+ this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpPduDeviceEntry 6 }
+
+tlpPduDeviceTemperatureF OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "degrees Fahrenheit"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The ambient temperature at or near the PDU casing. Temperature
+ measurements are not supported on all models. If not supported,
+ this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpPduDeviceEntry 7 }
+
+tlpPduDevicePhaseImbalance OBJECT-TYPE
+ SYNTAX INTEGER (0..200)
+ UNITS "percent"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The percentage of imbalance of the three phases. This value is in
+ the range from 0% imbalance to 100% imbalance. The lower the value,
+ the better balanced the phases are. If all load is on a single phase,
+ the imbalance is defined as 100%."
+ ::= { tlpPduDeviceEntry 8 }
+
+tlpPduDeviceOutputPowerTotal OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "Watts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The AC output total power for all circuits."
+ ::= { tlpPduDeviceEntry 9 }
+
+tlpPduDeviceAggregatePowerFactor OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Watts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The aggregate power factor of all phases."
+ ::= { tlpPduDeviceEntry 10 }
+
+tlpPduDeviceOutputCurrentPrecision OBJECT-TYPE
+ SYNTAX INTEGER {
+ wholeNumber(0),
+ tenths(1),
+ hundredths(2) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Output current is reported by tlpPduOutputCurrent, tlpPduOutputCurrentMin
+ and tlpPduOutputCurrentMax. These values are all reported in hundredths(0.01A),
+ which accommodates all models; however, on any given device the actual precision
+ may vary. All current values must be divided by 100 to obtain the actual value.
+ For example, if tlpPduOutputCurrent reports 500, then the actual output current
+ is 5.00. This tlpPduDeviceOutputCurrentPrecision defines the actual resolution
+ of that value: wholeNumber(0) is 5, tenths(1) is 5.0 and hundredths(2) is 5.00."
+ ::= { tlpPduDeviceEntry 11 }
+
+tlpPduInputTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpPduInputEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The input details of each pdu in device table. This is a sparse
+ dependent table, and will contain the number of entries based upon
+ the number of pdus managed by the agent as reported by tlpPduIdentNumPdus."
+ ::= { tlpPduInput 1 }
+
+tlpPduInputEntry OBJECT-TYPE
+ SYNTAX TlpPduInputEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing information applicable to a particular pdu managed
+ by this agent."
+ INDEX { tlpDeviceIndex }
+ ::= { tlpPduInputTable 1 }
+
+TlpPduInputEntry ::= SEQUENCE {
+ tlpPduInputNominalVoltage Unsigned32,
+ tlpPduInputNominalVoltagePhaseToPhase Unsigned32,
+ tlpPduInputNominalVoltagePhaseToNeutral Unsigned32,
+ tlpPduInputLowTransferVoltage Unsigned32,
+ tlpPduInputLowTransferVoltageLowerBound Unsigned32,
+ tlpPduInputLowTransferVoltageUpperBound Unsigned32,
+ tlpPduInputHighTransferVoltage Unsigned32,
+ tlpPduInputHighTransferVoltageLowerBound Unsigned32,
+ tlpPduInputHighTransferVoltageUpperBound Unsigned32,
+ tlpPduInputCurrentLimit Unsigned32 }
+
+tlpPduInputNominalVoltage OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The nominal value of the input line voltage. This value may not
+ be supported on all models. If not supported, this value will return
+ ERROR_NO_SUCH_NAME."
+ ::= { tlpPduInputEntry 1 }
+
+tlpPduInputNominalVoltagePhaseToPhase OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Volts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The nominal value of the input line voltage as measured from
+ phase to phase. This value may not be supported on all models.
+ If not supported, this value will always return zero."
+ ::= { tlpPduInputEntry 2 }
+
+tlpPduInputNominalVoltagePhaseToNeutral OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Volts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The nominal value of the input line voltage as measured from
+ phase to neutral. This value may not be supported on all models.
+ If not supported, this value will always return zero."
+ ::= { tlpPduInputEntry 3 }
+
+tlpPduInputLowTransferVoltage OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Volts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The minimum line voltage allowed before the unit disconnects the
+ AC input connection. This value may not be writable on all models.
+ If not writable, the value will be rejected and an appropriate error
+ message will be returned. When supported, the minimum and maximum
+ values allowed are dictated by tlpPduInputLowTransferVoltageLowerBound
+ and tlpPduInputLowTransferVoltageUpperBound respectively."
+ ::= { tlpPduInputEntry 4 }
+
+tlpPduInputLowTransferVoltageLowerBound OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Volts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The lower boundary value of tlpPduInputLowTransferVoltage as dictated
+ by the hardware of the unit."
+ ::= { tlpPduInputEntry 5 }
+
+tlpPduInputLowTransferVoltageUpperBound OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Volts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The upper boundary value of tlpPduInputLowTransferVoltage as dictated
+ by the hardware of the unit."
+ ::= { tlpPduInputEntry 6 }
+
+tlpPduInputHighTransferVoltage OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Volts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The maximum line voltage allowed before the unit disconnects the
+ AC input connection. This value may not be writable on all models.
+ If not writable, the value will be rejected and an appropriate error
+ message will be returned. When supported, the minimum and maximum
+ values allowed are dictated by tlpPduInputHighTransferVoltageLowerBound
+ and tlpPduInputHighTransferVoltageUpperBound respectively."
+ ::= { tlpPduInputEntry 7 }
+
+tlpPduInputHighTransferVoltageLowerBound OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Volts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The lower boundary value of tlpPduInputHighTransferVoltage as dictated
+ by the hardware of the unit."
+ ::= { tlpPduInputEntry 8 }
+
+tlpPduInputHighTransferVoltageUpperBound OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Volts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The upper boundary value of tlpPduInputHighTransferVoltage as dictated
+ by the hardware of the unit."
+ ::= { tlpPduInputEntry 9 }
+
+tlpPduInputCurrentLimit OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "Amps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The capacity of each phase conductor in the pdu limited by the AC input
+ cord or any other potential limiting factors unique to a given unit."
+ ::= { tlpPduInputEntry 10 }
+
+tlpPduInputPhaseTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpPduInputPhaseEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The input phase details of each pdu in device table. This is a sparse
+ dependent table, and will contain the number of entries based upon
+ the value of tlpPduIdentNumInputs and tlpPduIdentNumPhases per each
+ device."
+ ::= { tlpPduInput 2 }
+
+tlpPduInputPhaseEntry OBJECT-TYPE
+ SYNTAX TlpPduInputPhaseEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing information applicable to a particular input
+ phase managed by this agent."
+ INDEX { tlpDeviceIndex, tlpPduInputPhaseIndex }
+ ::= { tlpPduInputPhaseTable 1 }
+
+TlpPduInputPhaseEntry ::= SEQUENCE {
+ tlpPduInputPhaseIndex Unsigned32,
+ tlpPduInputPhasePhaseType INTEGER,
+ tlpPduInputPhaseFrequency Unsigned32,
+ tlpPduInputPhaseVoltage Unsigned32,
+ tlpPduInputPhaseVoltageMin Unsigned32,
+ tlpPduInputPhaseVoltageMax Unsigned32,
+ tlpPduInputPhaseCurrent Unsigned32 }
+
+tlpPduInputPhaseIndex OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The table row index for the pdu phase."
+ ::= { tlpPduInputPhaseEntry 1 }
+
+tlpPduInputPhasePhaseType OBJECT-TYPE
+ SYNTAX INTEGER {
+ phaseToNeutral(0),
+ phaseToPhase(1) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Denotes whether measurements are phase to neutral(0) or phase
+ to phase(1)."
+ ::= { tlpPduInputPhaseEntry 2 }
+
+tlpPduInputPhaseFrequency OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Hertz"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The present input frequency for a given phase."
+ ::= { tlpPduInputPhaseEntry 3 }
+
+tlpPduInputPhaseVoltage OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Volts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The magnitude of the present input voltage for a given phase."
+ ::= { tlpPduInputPhaseEntry 4 }
+
+tlpPduInputPhaseVoltageMin OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Volts"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The minimum input voltage value since the last reset of this
+ value for a given phase. If any value is written to either
+ tlpPduInputVoltageMin or tlpPduInputVoltageMax, both will be
+ reset to their appropriate minimum and maximum values."
+ ::= { tlpPduInputPhaseEntry 5 }
+
+tlpPduInputPhaseVoltageMax OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Volts"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The maximum input voltage value since the last reset of this
+ value for a given phase. If any value is written to either
+ tlpPduInputVoltageMin or tlpPduInputVoltageMax, both will be
+ reset to their appropriate minimum and maximum values."
+ ::= { tlpPduInputPhaseEntry 6 }
+
+tlpPduInputPhaseCurrent OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.01 Amps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The magnitude of the present input current for a given phase."
+ ::= { tlpPduInputPhaseEntry 7 }
+
+tlpPduOutputTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpPduOutputEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The output details of each pdu in device table. This is a sparse
+ dependent table, and will contain the number of entries based upon
+ the value of tlpPduIdentNumOutputs per each device."
+ ::= { tlpPduOutput 1 }
+
+tlpPduOutputEntry OBJECT-TYPE
+ SYNTAX TlpPduOutputEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing output information applicable to a particular
+ phase managed by this agent."
+ INDEX { tlpDeviceIndex, tlpPduOutputIndex }
+ ::= { tlpPduOutputTable 1 }
+
+TlpPduOutputEntry ::= SEQUENCE {
+ tlpPduOutputIndex Unsigned32,
+ tlpPduOutputPhase INTEGER,
+ tlpPduOutputPhaseType INTEGER,
+ tlpPduOutputVoltage Unsigned32,
+ tlpPduOutputCurrent Unsigned32,
+ tlpPduOutputCurrentMin Unsigned32,
+ tlpPduOutputCurrentMax Unsigned32,
+ tlpPduOutputActivePower Unsigned32,
+ tlpPduOutputPowerFactor Unsigned32,
+ tlpPduOutputSource INTEGER,
+ tlpPduOutputFrequency Unsigned32,
+ tlpPduOutputCalculatedPowerKVA Unsigned32,
+ tlpPduOutputCalculatedPowerKW Unsigned32,
+ tlpPduOutputCalculated24hrEnergy Unsigned32 }
+
+tlpPduOutputIndex OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The table row index for the pdu phase."
+ ::= { tlpPduOutputEntry 1 }
+
+tlpPduOutputPhase OBJECT-TYPE
+ SYNTAX INTEGER {
+ phase1(1),
+ phase2(2),
+ phase3(3) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the phase associated with the output line."
+ ::= { tlpPduOutputEntry 2 }
+
+tlpPduOutputPhaseType OBJECT-TYPE
+ SYNTAX INTEGER {
+ phaseToNeutral(0),
+ phaseToPhase(1) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Denotes whether measurements are phase to neutral(0) or phase
+ to phase(1)."
+ ::= { tlpPduOutputEntry 3 }
+
+tlpPduOutputVoltage OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Volts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The magnitude of the present output voltage for a given output line."
+ ::= { tlpPduOutputEntry 4 }
+
+tlpPduOutputCurrent OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.01 Amps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The output current, in hundredths of amps, for a given phase.
+ The actual precision of this value, whether a whole number, tenths
+ or hundredths, is returned by tlpPduDeviceOutputCurrentPrecision."
+ ::= { tlpPduOutputEntry 5 }
+
+tlpPduOutputCurrentMin OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.01 Amps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The minimum current, in hundredths of amps, observed for a given phase since last reset.
+ The actual precision of this value, whether a whole number, tenths or hundredths, is
+ returned by tlpPduDeviceOutputCurrentPrecision."
+ ::= { tlpPduOutputEntry 6 }
+
+tlpPduOutputCurrentMax OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.01 Amps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The maximum current, in hundredths of amps, observed for a given phase since last reset.
+ The actual precision of this value, whether a whole number, tenths or hundredths, is
+ returned by tlpPduDeviceOutputCurrentPrecision."
+ ::= { tlpPduOutputEntry 7 }
+
+tlpPduOutputActivePower OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "Watts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The output power for a given phase."
+ ::= { tlpPduOutputEntry 8 }
+
+tlpPduOutputPowerFactor OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.01 percent"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The output power factor, in hundredths of a percent, for a given
+ phase."
+ ::= { tlpPduOutputEntry 9 }
+
+tlpPduOutputSource OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(0),
+ normal(1) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The present source of output power. The enumeration none(0)
+ indicates that there is no source of output power (and
+ therefore no output power), for example, the system has opened
+ the output breaker."
+ ::= { tlpPduOutputEntry 10 }
+
+tlpPduOutputFrequency OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Hertz"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The present output frequency. If not supported, the agent reports ERROR_NO_SUCH_NAME."
+ ::= { tlpPduOutputEntry 11 }
+
+
+tlpPduOutputCalculatedPowerKVA OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.01 KVA"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The calculated amount of apparent power being used."
+ ::= { tlpPduOutputEntry 12 }
+
+tlpPduOutputCalculatedPowerKW OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.01 KW"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The calculated amount of active power being used."
+ ::= { tlpPduOutputEntry 13 }
+
+tlpPduOutputCalculated24hrEnergy OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.01 KWH"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Estimated 24 hour power consumption using present value
+ of tlpPduOutputCalculatedPowerKW."
+ ::= { tlpPduOutputEntry 14 }
+
+
+tlpPduOutletTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpPduOutletEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The receptacle status details of each pdu in device table. This
+ is a sparse dependent table, and will contain the number of entries
+ based upon the value of tlpPduIdentNumOutlets per each device."
+ ::= { tlpPduOutlet 1 }
+
+tlpPduOutletEntry OBJECT-TYPE
+ SYNTAX TlpPduOutletEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing information applicable to a particular outlet
+ managed by this agent."
+ INDEX { tlpDeviceIndex, tlpPduOutletIndex }
+ ::= { tlpPduOutletTable 1 }
+
+TlpPduOutletEntry ::= SEQUENCE {
+ tlpPduOutletIndex Unsigned32,
+ tlpPduOutletName DisplayString,
+ tlpPduOutletDescription DisplayString,
+ tlpPduOutletState INTEGER,
+ tlpPduOutletControllable TruthValue,
+ tlpPduOutletCommand INTEGER,
+ tlpPduOutletVoltage Unsigned32,
+ tlpPduOutletCurrent Unsigned32,
+ tlpPduOutletPower Unsigned32,
+ tlpPduOutletRampAction INTEGER,
+ tlpPduOutletRampDelay Integer32,
+ tlpPduOutletShedAction INTEGER,
+ tlpPduOutletShedDelay Integer32,
+ tlpPduOutletGroup Integer32,
+ tlpPduOutletBank Integer32,
+ tlpPduOutletCircuit Integer32,
+ tlpPduOutletPhase INTEGER }
+
+tlpPduOutletIndex OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The table row index for the pdu outlet."
+ ::= { tlpPduOutletEntry 1 }
+
+tlpPduOutletName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A user-definable string identifying the name of the outlet."
+ ::= { tlpPduOutletEntry 2 }
+
+tlpPduOutletDescription OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A user-definable string identifying the device(s) connected to
+ the given outlet."
+ ::= { tlpPduOutletEntry 3 }
+
+tlpPduOutletState OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(0),
+ off(1),
+ on(2) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current state of the outlet."
+ ::= { tlpPduOutletEntry 4 }
+
+tlpPduOutletControllable OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Denotes whether this outlet is controllable."
+ ::= { tlpPduOutletEntry 5 }
+
+tlpPduOutletCommand OBJECT-TYPE
+ SYNTAX INTEGER {
+ idle(0),
+ turnOff(1),
+ turnOn(2),
+ cycle(3) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Reading this value will always return 0. Setting this value
+ to turnOff(1) will turn off the outlet. Setting this value
+ to turnOn(2) will turn on the outlet. Setting this value to
+ cycle(3) will turn the outlet off, then turn it back on."
+ ::= { tlpPduOutletEntry 6 }
+
+tlpPduOutletVoltage OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Volts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The magnitude of the present output voltage for a given outlet.
+ If the voltage measurement is not supported for an individual
+ receptacle regardless whether device-wide or just for this
+ receptacle, then this value will always return ERROR_NO_SUCH_NAME.
+ Device-wide support for receptacle voltage measurements is denoted
+ by tlpPduSupportsOutletVoltage."
+ ::= { tlpPduOutletEntry 7 }
+
+tlpPduOutletCurrent OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.01 Amps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The present output current, in hundredths of amps, of a given outlet.
+ If the current measurement is not supported for an individual
+ receptacle regardless whether device-wide or just for this
+ receptacle, then this value will always return ERROR_NO_SUCH_NAME.
+ Device-wide support for receptacle current measurements is denoted
+ by tlpPduSupportsCurrentPower."
+ ::= { tlpPduOutletEntry 8 }
+
+tlpPduOutletPower OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "Watts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The output power of a given outlet. If the power measurement is
+ not supported for an individual receptacle regardless whether
+ device-wide or just for this receptacle, then this value will
+ always return ERROR_NO_SUCH_NAME. Device-wide support for receptacle
+ power measurements is denoted by tlpPduSupportsCurrentPower."
+ ::= { tlpPduOutletEntry 9 }
+
+tlpPduOutletRampAction OBJECT-TYPE
+ SYNTAX INTEGER {
+ remainOff(0),
+ turnOnAfterDelay(1) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The ramp action to take on a given outlet when powering on the
+ device. If this receptacle is not controllable, as denoted by
+ tlpPduOutletControllable, then this value will always return
+ ERROR_NO_SUCH_NAME."
+ ::= { tlpPduOutletEntry 10 }
+
+tlpPduOutletRampDelay OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "seconds"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The number of seconds to delay before powering on the given outlet.
+ If this receptacle is not controllable, as denoted by
+ tlpPduOutletControllable, then this value will always return
+ ERROR_NO_SUCH_NAME."
+ ::= { tlpPduOutletEntry 11 }
+
+tlpPduOutletShedAction OBJECT-TYPE
+ SYNTAX INTEGER {
+ remainOn(0),
+ turnOffAfterDelay(1) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The shed action to take on a given outlet when powering off the
+ device. If this receptacle is not controllable, as denoted by
+ tlpPduOutletControllable, then this value will always return
+ ERROR_NO_SUCH_NAME."
+ ::= { tlpPduOutletEntry 12 }
+
+tlpPduOutletShedDelay OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "seconds"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The number of seconds to delay before powering off the given outlet.
+ If this receptacle is not controllable, as denoted by
+ tlpPduOutletControllable, then this value will always return
+ ERROR_NO_SUCH_NAME."
+ ::= { tlpPduOutletEntry 13 }
+
+tlpPduOutletGroup OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The tlpPduOutletGroupIndex group index of the respective group to
+ which the given outlet is assigned, or zero (0) if the given
+ outlet is not grouped."
+ ::= { tlpPduOutletEntry 14 }
+
+tlpPduOutletBank OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates on which bank the given outlet is located."
+ ::= { tlpPduOutletEntry 15 }
+
+tlpPduOutletCircuit OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates on which circuit the given outlet is wired."
+ ::= { tlpPduOutletEntry 16 }
+
+tlpPduOutletPhase OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(0),
+ phase1(1),
+ phase2(2),
+ phase3(3),
+ phase1-2(4),
+ phase2-3(5),
+ phase3-1(6) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates on which phase or phases the given outlet is
+ associated. For single phase devices, this object will
+ always return phase1(1). For 3-phase devices with outlets
+ wired to a single phase, this object will return phase1(1),
+ phase2(2) or phase3(3). For 3-phase devices with outlets
+ wired to two phases, this object will return phase1-2(4)
+ for phases 1 and 2, phase2-3(5) for phases 2 and 3, and
+ phase3-1(6) for phases 3 and 1. Devices that do not report
+ phase connections will return unknown(0)."
+ ::= { tlpPduOutletEntry 17 }
+
+tlpPduOutletGroupTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpPduOutletGroupEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The receptacle grouping details of each pdu in device table.
+ This is a sparse dependent table, and will contain the number
+ of entries based upon the value of tlpPduIdentNumOutletGroups per
+ each device."
+ ::= { tlpPduOutlet 2 }
+
+tlpPduOutletGroupEntry OBJECT-TYPE
+ SYNTAX TlpPduOutletGroupEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing information applicable to a particular outlet
+ group managed by this agent."
+ INDEX { tlpDeviceIndex, tlpPduOutletGroupIndex }
+ ::= { tlpPduOutletGroupTable 1 }
+
+TlpPduOutletGroupEntry ::= SEQUENCE {
+ tlpPduOutletGroupIndex Unsigned32,
+ tlpPduOutletGroupRowStatus RowStatus,
+ tlpPduOutletGroupName DisplayString,
+ tlpPduOutletGroupDescription DisplayString,
+ tlpPduOutletGroupState INTEGER,
+ tlpPduOutletGroupCommand INTEGER }
+
+tlpPduOutletGroupIndex OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The table row index for the pdu outlet group."
+ ::= { tlpPduOutletGroupEntry 1 }
+
+tlpPduOutletGroupRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Row status for the tlpPduOutletGroupTable"
+ ::= { tlpPduOutletGroupEntry 2 }
+
+tlpPduOutletGroupName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The name of this outlet group."
+ ::= { tlpPduOutletGroupEntry 3 }
+
+tlpPduOutletGroupDescription OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A description for this outlet group."
+ ::= { tlpPduOutletGroupEntry 4 }
+
+tlpPduOutletGroupState OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(0),
+ off(1),
+ on(2),
+ mixed(3) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current state of the outlet group. This value will report
+ off(1) if all outlets in the group are off, on(2) if all outlets
+ in the group are on, mixed(3) if some outlets in the group are
+ off and others are on, or unknown(0) if the state of the outlets
+ cannot be determined."
+ ::= { tlpPduOutletGroupEntry 5 }
+
+tlpPduOutletGroupCommand OBJECT-TYPE
+ SYNTAX INTEGER {
+ turnOff(1),
+ turnOn(2),
+ cycle(3) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Reading this value will always return 0. Setting this value to
+ turnOff(1) will turn off every outlet associated with the group.
+ Setting this value to turnOn(2) will turn on every outlet associated
+ with the group. Setting this value to cycle(3) will turn off every
+ outlet associated with the group, then turn each outlet back on."
+ ::= { tlpPduOutletGroupEntry 6 }
+
+tlpPduCircuitTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpPduCircuitEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of pdu circuit table entries. The number of entries
+ is given by the value of tlpPduIdentNumCircuits."
+ ::= { tlpPduCircuit 1 }
+
+tlpPduCircuitEntry OBJECT-TYPE
+ SYNTAX TlpPduCircuitEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing information applicable to a particular circuit
+ managed by this agent."
+ INDEX { tlpDeviceIndex, tlpPduCircuitIndex }
+ ::= { tlpPduCircuitTable 1 }
+
+TlpPduCircuitEntry ::= SEQUENCE {
+ tlpPduCircuitIndex Unsigned32,
+ tlpPduCircuitPhase INTEGER,
+ tlpPduCircuitInputVoltage Integer32,
+ tlpPduCircuitTotalCurrent Integer32,
+ tlpPduCircuitCurrentLimit Integer32,
+ tlpPduCircuitCurrentMin Integer32,
+ tlpPduCircuitCurrentMax Integer32,
+ tlpPduCircuitTotalPower Integer32,
+ tlpPduCircuitPowerFactor INTEGER,
+ tlpPduCircuitUtilization Unsigned32 }
+
+tlpPduCircuitIndex OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The table row index for the pdu circuit."
+ ::= { tlpPduCircuitEntry 1 }
+
+tlpPduCircuitPhase OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(0),
+ phase1(1),
+ phase2(2),
+ phase3(3),
+ phase1-2(4),
+ phase2-3(5),
+ phase3-1(6) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates on which phase or phases the given circuit is
+ wired. For single phase devices, this object will always
+ return phase1(1). For 3-phase devices with outlets wired
+ to a single phase, this object will return phase1(1),
+ phase2(2) or phase3(3). For 3-phase devices with outlets
+ wired to two phases, this object will return phase1-2(4)
+ for phases 1 and 2, phase2-3(5) for phases 2 and 3, and
+ phase3-1(6) for phases 3 and 1. Devices that do not report
+ phase connections will return unknown(0)."
+ ::= { tlpPduCircuitEntry 2 }
+
+tlpPduCircuitInputVoltage OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 Volts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The input voltage for a circuit."
+ ::= { tlpPduCircuitEntry 3 }
+
+tlpPduCircuitTotalCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.01 Amps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total current, in hundredths of amps, for all receptacles
+ in a given circuit."
+ ::= { tlpPduCircuitEntry 4 }
+
+tlpPduCircuitCurrentLimit OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.01 Amps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current capacity, in hundredths of amps, of a circuit in
+ the system limited by the circuit breaker or wiring used in a
+ given unit."
+ ::= { tlpPduCircuitEntry 5 }
+
+tlpPduCircuitCurrentMin OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.01 Amps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The minimum total current, in hundredths of amps, for
+ all receptacles in a given circuit since last reset."
+ ::= { tlpPduCircuitEntry 6 }
+
+tlpPduCircuitCurrentMax OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.01 Amps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The maximum total current, in hundredths of amps, for
+ all receptacles in a given circuit since last reset."
+ ::= { tlpPduCircuitEntry 7 }
+
+tlpPduCircuitTotalPower OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "Watts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total power for all receptacles in a given circuit."
+ ::= { tlpPduCircuitEntry 8 }
+
+tlpPduCircuitPowerFactor OBJECT-TYPE
+ SYNTAX INTEGER (0..200)
+ UNITS "percent"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The power factor for all receptacles in a given circuit."
+ ::= { tlpPduCircuitEntry 9 }
+
+tlpPduCircuitUtilization OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.01 percent"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The percentage of utilization of a given circuit. This is typically
+ a calculation of tlpPduCircuitTotalCurrent / tlpPduCircuitCurrentLimit."
+ ::= { tlpPduCircuitEntry 10 }
+
+tlpPduBreakerTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpPduBreakerEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of pdu bank breaker table entries. The number of entries
+ is given by the value of tlpPduIdentNumBreakers."
+ ::= { tlpPduBreaker 1 }
+
+tlpPduBreakerEntry OBJECT-TYPE
+ SYNTAX TlpPduBreakerEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing information applicable to a particular bank
+ breaker managed by this agent."
+ INDEX { tlpDeviceIndex, tlpPduBreakerIndex }
+ ::= { tlpPduBreakerTable 1 }
+
+TlpPduBreakerEntry ::= SEQUENCE {
+ tlpPduBreakerIndex Unsigned32,
+ tlpPduBreakerStatus INTEGER }
+
+tlpPduBreakerIndex OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The table row index for the pdu bank breaker."
+ ::= { tlpPduBreakerEntry 1 }
+
+tlpPduBreakerStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ open(0),
+ closed(1),
+ notInstalled(2) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates whether the bank breaker is open(0), closed(1) or not
+ installed(2)."
+ ::= { tlpPduBreakerEntry 2 }
+
+tlpPduHeatsinkTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpPduHeatsinkEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of pdu heatsink thermistor table entries. The number of entries
+ is given by the value of tlpPduIdentNumHeatsinks."
+ ::= { tlpPduHeatsink 1 }
+
+tlpPduHeatsinkEntry OBJECT-TYPE
+ SYNTAX TlpPduHeatsinkEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing information applicable to a particular heatsink
+ thermistor managed by this agent."
+ INDEX { tlpDeviceIndex, tlpPduHeatsinkIndex }
+ ::= { tlpPduHeatsinkTable 1 }
+
+TlpPduHeatsinkEntry ::= SEQUENCE {
+ tlpPduHeatsinkIndex Unsigned32,
+ tlpPduHeatsinkStatus INTEGER,
+ tlpPduHeatsinkTemperatureC Integer32,
+ tlpPduHeatsinkTemperatureF Integer32 }
+
+tlpPduHeatsinkIndex OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The table row index for the pdu heatsink thermistor."
+ ::= { tlpPduHeatsinkEntry 1 }
+
+tlpPduHeatsinkStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ notAvailable(0),
+ available(1) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates whether the heatsink thermistor is available. The entry
+ will return notAvailable(0) if a thermistor is either non-existent or
+ disconnected, or available(1) when connected."
+ ::= { tlpPduHeatsinkEntry 2 }
+
+tlpPduHeatsinkTemperatureC OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 degrees Celsius"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The temperature at the heatsink thermistor in tenths degrees Celsius.
+ Heatsink temperature measurements are not supported on all models. If
+ not supported, this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpPduHeatsinkEntry 3 }
+
+tlpPduHeatsinkTemperatureF OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 degrees Fahrenheit"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The temperature at the heatsink thermistor in tenths degrees Fahrenheit.
+ Heatsink temperature measurements are not supported on all models. If
+ not supported, this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpPduHeatsinkEntry 4 }
+
+tlpPduControlTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpPduControlEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The actionable controls for each pdu in device table. This is a
+ sparse dependent table, and will contain some subset of devices
+ that are pdus."
+ ::= { tlpPduControl 1 }
+
+tlpPduControlEntry OBJECT-TYPE
+ SYNTAX TlpPduControlEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing controls for a particular pdu."
+ INDEX { tlpDeviceIndex }
+ ::= { tlpPduControlTable 1 }
+
+TlpPduControlEntry ::= SEQUENCE {
+ tlpPduControlRamp TruthValue,
+ tlpPduControlShed TruthValue,
+ tlpPduControlPduOn TruthValue,
+ tlpPduControlPduOff TruthValue,
+ tlpPduControlPduReboot TruthValue }
+
+tlpPduControlRamp OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Set to TRUE to initiate the pre-designated ramp
+ sequence on the pdu."
+ ::= { tlpPduControlEntry 1 }
+
+tlpPduControlShed OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Set to TRUE to initiate the pre-designated shed
+ sequence on the pdu."
+ ::= { tlpPduControlEntry 2 }
+
+tlpPduControlPduOn OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Set to TRUE to turn the pdu on."
+ ::= { tlpPduControlEntry 3 }
+
+tlpPduControlPduOff OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Set to TRUE to turn the pdu off."
+ ::= { tlpPduControlEntry 4 }
+
+tlpPduControlPduReboot OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Set to TRUE to reboot the pdu."
+ ::= { tlpPduControlEntry 5 }
+
+tlpPduConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpPduConfigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The configuration options of each pdu in device table. This
+ is a sparse dependent table, and will contain some subset of
+ devices that are pdus. Not all options are available on all
+ pdus."
+ ::= { tlpPduConfig 1 }
+
+tlpPduConfigEntry OBJECT-TYPE
+ SYNTAX TlpPduConfigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing configuration options for a particular pdu."
+ INDEX { tlpDeviceIndex }
+ ::= { tlpPduConfigTable 1 }
+
+TlpPduConfigEntry ::= SEQUENCE {
+ tlpPduConfigInputVoltage Unsigned32 }
+
+tlpPduConfigInputVoltage OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The nominal value of the input line voltage. This value may not
+ be supported on all models. If not supported, this value will return
+ ERROR_NO_SUCH_NAME. This value may not be writable on all models. If
+ not writable, the value will be rejected and an appropriate error
+ message will be returned."
+ ::= { tlpPduConfigEntry 1 }
+
+tlpPduConfigPhaseThresholdTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpPduConfigPhaseThresholdEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The configuration options of each pdu in device table. This
+ is a sparse dependent table, and will contain some subset of
+ devices that are pdus. Not all options are available on all
+ pdus."
+ ::= { tlpPduConfig 2 }
+
+tlpPduConfigPhaseThresholdEntry OBJECT-TYPE
+ SYNTAX TlpPduConfigPhaseThresholdEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing threshold configuration options for a particular pdu."
+ INDEX { tlpDeviceIndex, tlpPduPhaseIndex }
+ ::= { tlpPduConfigPhaseThresholdTable 1 }
+
+TlpPduConfigPhaseThresholdEntry ::= SEQUENCE {
+ tlpPduPhaseIndex Unsigned32,
+ tlpPduConfigOutputCurrentThresholdTolerance Unsigned32,
+ tlpPduConfigOutputCurrentHighThreshold Unsigned32,
+ tlpPduConfigOutputCurrentLowThreshold Unsigned32}
+
+tlpPduPhaseIndex OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The table row index for the pdu phase."
+ ::= { tlpPduConfigPhaseThresholdEntry 1 }
+
+tlpPduConfigOutputCurrentThresholdTolerance OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Amps"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The threshold tolerance value used together with output current high/low
+ threshold to evaluate output current high/low condition."
+ ::= { tlpPduConfigPhaseThresholdEntry 2 }
+
+tlpPduConfigOutputCurrentHighThreshold OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Amps"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The value at which a output current high condition is declared."
+ ::= { tlpPduConfigPhaseThresholdEntry 3 }
+
+tlpPduConfigOutputCurrentLowThreshold OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Amps"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The value at which a output current low condition is declared."
+ ::= { tlpPduConfigPhaseThresholdEntry 4 }
+
+-- envirosense
+
+tlpEnvIdentNumEnvirosense OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of envirosense devices that this agent is currently managing."
+ ::= { tlpEnvIdent 1 }
+
+tlpEnvIdentTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpEnvIdentEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The identity details of each envirosense in device table. This is a
+ sparse dependent table, and will contain some subset of devices
+ that are envirosenses."
+ ::= { tlpEnvIdent 2 }
+
+tlpEnvIdentEntry OBJECT-TYPE
+ SYNTAX TlpEnvIdentEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing details for a particular envirosense."
+ INDEX { tlpDeviceIndex }
+ ::= { tlpEnvIdentTable 1 }
+
+TlpEnvIdentEntry ::= SEQUENCE {
+ tlpEnvIdentTempSupported TruthValue,
+ tlpEnvIdentHumiditySupported TruthValue,
+ tlpEnvNumInputContacts Unsigned32,
+ tlpEnvNumOutputContacts Unsigned32 }
+
+tlpEnvIdentTempSupported OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates whether or not temperature is supported."
+ ::= { tlpEnvIdentEntry 1 }
+
+tlpEnvIdentHumiditySupported OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates whether or not temperature is supported."
+ ::= { tlpEnvIdentEntry 2 }
+
+tlpEnvNumInputContacts OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of input contacts supported by the envirosense."
+ ::= { tlpEnvIdentEntry 3 }
+
+tlpEnvNumOutputContacts OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of output contacts supported by the envirosense."
+ ::= { tlpEnvIdentEntry 4 }
+
+tlpEnvTemperatureTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpEnvTemperatureEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The temperature details of each envirosense in device table. The
+ number of entries is given by the value of tlpDevicesNumDevices."
+ ::= { tlpEnvDetail 1 }
+
+tlpEnvTemperatureEntry OBJECT-TYPE
+ SYNTAX TlpEnvTemperatureEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing temperature details for a particular
+ envirosense."
+ INDEX { tlpDeviceIndex }
+ ::= { tlpEnvTemperatureTable 1 }
+
+TlpEnvTemperatureEntry ::= SEQUENCE {
+ tlpEnvTemperatureC Integer32,
+ tlpEnvTemperatureF Integer32,
+ tlpEnvTemperatureInAlarm TruthValue }
+
+tlpEnvTemperatureC OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 degrees Celsius"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The ambient temperature."
+ ::= { tlpEnvTemperatureEntry 1 }
+
+tlpEnvTemperatureF OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 degrees Fahrenheit"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The ambient temperature."
+ ::= { tlpEnvTemperatureEntry 2 }
+
+tlpEnvTemperatureInAlarm OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates whether or not temperature is in alarm."
+ ::= { tlpEnvTemperatureEntry 3 }
+
+tlpEnvHumidityTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpEnvHumidityEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The humidity details of each envirosense in device table. The
+ number of entries is given by the value of tlpDevicesNumDevices."
+ ::= { tlpEnvDetail 2 }
+
+tlpEnvHumidityEntry OBJECT-TYPE
+ SYNTAX TlpEnvHumidityEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing humidity details for a particular
+ envirosense."
+ INDEX { tlpDeviceIndex }
+ ::= { tlpEnvHumidityTable 1 }
+
+TlpEnvHumidityEntry ::= SEQUENCE {
+ tlpEnvHumidityHumidity INTEGER,
+ tlpEnvHumidityInAlarm TruthValue }
+
+tlpEnvHumidityHumidity OBJECT-TYPE
+ SYNTAX INTEGER (0..100)
+ UNITS "percent"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The ambient humidity."
+ ::= { tlpEnvHumidityEntry 1 }
+
+tlpEnvHumidityInAlarm OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates whether or not humidity is in alarm."
+ ::= { tlpEnvHumidityEntry 2 }
+
+tlpEnvInputContactTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpEnvInputContactEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The input contact details of each envirosense in device table.
+ The number of entries is given by the value of tlpDevicesNumDevices."
+ ::= { tlpEnvDetail 3 }
+
+tlpEnvInputContactEntry OBJECT-TYPE
+ SYNTAX TlpEnvInputContactEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing input contact details for a particular
+ envirosense."
+ INDEX { tlpDeviceIndex, tlpEnvInputContactIndex }
+ ::= { tlpEnvInputContactTable 1 }
+
+TlpEnvInputContactEntry ::= SEQUENCE {
+ tlpEnvInputContactIndex Unsigned32,
+ tlpEnvInputContactName DisplayString,
+ tlpEnvInputContactNormalState INTEGER,
+ tlpEnvInputContactCurrentState INTEGER,
+ tlpEnvInputContactInAlarm TruthValue }
+
+tlpEnvInputContactIndex OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The table row index for the envirosense input contact details."
+ ::= { tlpEnvInputContactEntry 1 }
+
+tlpEnvInputContactName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The name or description of the contact."
+ ::= { tlpEnvInputContactEntry 2 }
+
+tlpEnvInputContactNormalState OBJECT-TYPE
+ SYNTAX INTEGER {
+ open(0),
+ closed(1) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The normal operating position of the contact."
+ ::= { tlpEnvInputContactEntry 3 }
+
+tlpEnvInputContactCurrentState OBJECT-TYPE
+ SYNTAX INTEGER {
+ open(0),
+ closed(1) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current state of the contact."
+ ::= { tlpEnvInputContactEntry 4 }
+
+tlpEnvInputContactInAlarm OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates whether or not the contact is in alarm."
+ ::= { tlpEnvInputContactEntry 5 }
+
+tlpEnvOutputContactTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpEnvOutputContactEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The output contact details of each envirosense in device table.
+ The number of entries is given by the value of tlpDevicesNumDevices."
+ ::= { tlpEnvDetail 4 }
+
+tlpEnvOutputContactEntry OBJECT-TYPE
+ SYNTAX TlpEnvOutputContactEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing output contact details for a particular
+ envirosense."
+ INDEX { tlpDeviceIndex, tlpEnvOutputContactIndex }
+ ::= { tlpEnvOutputContactTable 1 }
+
+TlpEnvOutputContactEntry ::= SEQUENCE {
+ tlpEnvOutputContactIndex Unsigned32,
+ tlpEnvOutputContactName DisplayString,
+ tlpEnvOutputContactNormalState INTEGER,
+ tlpEnvOutputContactCurrentState INTEGER,
+ tlpEnvOutputContactInAlarm TruthValue }
+
+tlpEnvOutputContactIndex OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The table row index for the envirosense output contact details."
+ ::= { tlpEnvOutputContactEntry 1 }
+
+tlpEnvOutputContactName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The name or description of the contact."
+ ::= { tlpEnvOutputContactEntry 2 }
+
+tlpEnvOutputContactNormalState OBJECT-TYPE
+ SYNTAX INTEGER {
+ open(0),
+ closed(1) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The normal operating position of the contact."
+ ::= { tlpEnvOutputContactEntry 3 }
+
+tlpEnvOutputContactCurrentState OBJECT-TYPE
+ SYNTAX INTEGER {
+ open(0),
+ closed(1) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The current state of the contact."
+ ::= { tlpEnvOutputContactEntry 4 }
+
+tlpEnvOutputContactInAlarm OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates whether or not the contact is in alarm."
+ ::= { tlpEnvOutputContactEntry 5 }
+
+tlpEnvConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpEnvConfigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The configuration options of each envirosense in device table.
+ This is a sparse dependent table, and will contain some subset of
+ devices that are envirosenses. Not all options are available on
+ all envirosenses."
+ ::= { tlpEnvConfig 1 }
+
+tlpEnvConfigEntry OBJECT-TYPE
+ SYNTAX TlpEnvConfigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing configuration options for a particular
+ envirosenses."
+ INDEX { tlpDeviceIndex }
+ ::= { tlpEnvConfigTable 1 }
+
+TlpEnvConfigEntry ::= SEQUENCE {
+ tlpEnvTemperatureLowLimit Integer32,
+ tlpEnvTemperatureHighLimit Integer32,
+ tlpEnvHumidityLowLimit INTEGER,
+ tlpEnvHumidityHighLimit INTEGER }
+
+tlpEnvTemperatureLowLimit OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "degrees Fahrenheit"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The lower alarm limit for ambient temperature."
+ ::= { tlpEnvConfigEntry 1 }
+
+tlpEnvTemperatureHighLimit OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "degrees Fahrenheit"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The upper alarm limit for ambient temperature."
+ ::= { tlpEnvConfigEntry 2 }
+
+tlpEnvHumidityLowLimit OBJECT-TYPE
+ SYNTAX INTEGER (0..100)
+ UNITS "percent"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The lower alarm limit for ambient humidity."
+ ::= { tlpEnvConfigEntry 3 }
+
+tlpEnvHumidityHighLimit OBJECT-TYPE
+ SYNTAX INTEGER (0..100)
+ UNITS "percent"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The upper alarm limit for ambient humidity."
+ ::= { tlpEnvConfigEntry 4 }
+
+-- ats
+
+tlpAtsIdentNumAts OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of ats devices that this agent is currently managing."
+ ::= { tlpAtsIdent 1 }
+
+tlpAtsIdentTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpAtsIdentEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The identity details of each ats in device table. This is a
+ sparse dependent table, and will contain some subset of devices
+ that are atss."
+ ::= { tlpAtsIdent 2 }
+
+tlpAtsIdentEntry OBJECT-TYPE
+ SYNTAX TlpAtsIdentEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing details for a particular ats."
+ INDEX { tlpDeviceIndex }
+ ::= { tlpAtsIdentTable 1 }
+
+TlpAtsIdentEntry ::= SEQUENCE {
+ tlpAtsIdentNumInputs Unsigned32,
+ tlpAtsIdentNumOutputs Unsigned32,
+ tlpAtsIdentNumPhases Unsigned32,
+ tlpAtsIdentNumOutlets Unsigned32,
+ tlpAtsIdentNumOutletGroups Unsigned32,
+ tlpAtsIdentNumCircuits Unsigned32,
+ tlpAtsIdentNumBreakers Unsigned32,
+ tlpAtsIdentNumHeatsinks Unsigned32 }
+
+tlpAtsIdentNumInputs OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of inputs supported by the ats."
+ ::= { tlpAtsIdentEntry 1 }
+
+tlpAtsIdentNumOutputs OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of outputs supported by the ats."
+ ::= { tlpAtsIdentEntry 2 }
+
+tlpAtsIdentNumPhases OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of phases per input supported by the ats."
+ ::= { tlpAtsIdentEntry 3 }
+
+tlpAtsIdentNumOutlets OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of receptacles supported by the ats."
+ ::= { tlpAtsIdentEntry 4 }
+
+tlpAtsIdentNumOutletGroups OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of receptacle groups supported by the ats."
+ ::= { tlpAtsIdentEntry 5 }
+
+tlpAtsIdentNumCircuits OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of circuits supported by the ats."
+ ::= { tlpAtsIdentEntry 6 }
+
+tlpAtsIdentNumBreakers OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of monitored bank breakers supported by the ats.
+ If the ats has breakers that are not monitored by the device,
+ the value of zero(0) will be returned."
+ ::= { tlpAtsIdentEntry 7 }
+
+tlpAtsIdentNumHeatsinks OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of heatsink thermistors supported by the ats."
+ ::= { tlpAtsIdentEntry 8 }
+
+tlpAtsSupportsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpAtsSupportsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The supported details of each ats in device table. This is a
+ sparse dependent table, and will contain some subset of devices
+ that are atss."
+ ::= { tlpAtsIdent 3 }
+
+tlpAtsSupportsEntry OBJECT-TYPE
+ SYNTAX TlpAtsSupportsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing supported details for a particular ats."
+ INDEX { tlpDeviceIndex }
+ ::= { tlpAtsSupportsTable 1 }
+
+TlpAtsSupportsEntry ::= SEQUENCE {
+ tlpAtsSupportsEnergywise TruthValue,
+ tlpAtsSupportsRampShed TruthValue,
+ tlpAtsSupportsOutletGroup TruthValue,
+ tlpAtsSupportsOutletCurrentPower TruthValue,
+ tlpAtsSupportsOutletVoltage TruthValue }
+
+tlpAtsSupportsEnergywise OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates whether the ats supports Cisco EnergyWise."
+ ::= { tlpAtsSupportsEntry 1 }
+
+tlpAtsSupportsRampShed OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates whether the ats supports ramping and shedding."
+ ::= { tlpAtsSupportsEntry 2 }
+
+tlpAtsSupportsOutletGroup OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates whether the ats supports outlet groups."
+ ::= { tlpAtsSupportsEntry 3 }
+
+tlpAtsSupportsOutletCurrentPower OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates whether the ats reports individual receptacle current
+ and power measurements. Devices that do not support individual
+ receptacle measurements will always return ERROR_NO_SUCH_NAME for
+ tlpAtsOutletCurrent and tlpAtsOutletPower."
+ ::= { tlpAtsSupportsEntry 4 }
+
+tlpAtsSupportsOutletVoltage OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates whether the ats reports individual receptacle voltage
+ measurements. Devices that do not support individual receptacle
+ measurements will always return ERROR_NO_SUCH_NAME for
+ tlpAtsOutletVoltage."
+ ::= { tlpAtsSupportsEntry 5 }
+
+tlpAtsDisplayTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpAtsDisplayEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The display details of each ats in device table. This is a
+ sparse dependent table, and will contain some subset of devices
+ that are atss."
+ ::= { tlpAtsIdent 4 }
+
+tlpAtsDisplayEntry OBJECT-TYPE
+ SYNTAX TlpAtsDisplayEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing display details for a particular ats."
+ INDEX { tlpDeviceIndex }
+ ::= { tlpAtsDisplayTable 1 }
+
+TlpAtsDisplayEntry ::= SEQUENCE {
+ tlpAtsDisplayScheme INTEGER,
+ tlpAtsDisplayOrientation INTEGER,
+ tlpAtsDisplayAutoScroll INTEGER,
+ tlpAtsDisplayIntensity INTEGER,
+ tlpAtsDisplayUnits INTEGER }
+
+tlpAtsDisplayScheme OBJECT-TYPE
+ SYNTAX INTEGER {
+ schemeReverse(0),
+ schemeNormal(1) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Indicates the display scheme of the LED display. The value
+ schemeReverse(0) indicates the tricolor LED indicator uses an
+ alternate pattern. The value schemeNormal(1) indicates the
+ LED indicator uses the standard pattern. This value may not
+ be supported on all models. If not supported, the value will
+ always return schemeNormal(1)."
+ ::= { tlpAtsDisplayEntry 1 }
+
+tlpAtsDisplayOrientation OBJECT-TYPE
+ SYNTAX INTEGER {
+ displayNormal(0),
+ displayReverse(1) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Indicates the physical orientation of the LED display. The value
+ displayNormal(0) indicates the display is right-side-up (normal).
+ The value displayReverse(1) indicates the display is upside-down.
+ This value may not be supported on all models. If not supported,
+ the value will always return displayNormal(0)."
+ ::= { tlpAtsDisplayEntry 2 }
+
+tlpAtsDisplayAutoScroll OBJECT-TYPE
+ SYNTAX INTEGER {
+ scrollDisabled(0),
+ scrollEnabled(1) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Indicates whether the LED display automatically scrolls through
+ displaying status values."
+ ::= { tlpAtsDisplayEntry 3 }
+
+tlpAtsDisplayIntensity OBJECT-TYPE
+ SYNTAX INTEGER {
+ intensity25(1),
+ intensity50(2),
+ intensity75(3),
+ intensity100(4) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Indicates the intensity, as a percentage, of the LED display. The
+ value intensity100(4) indicates the display is at 100% intensity.
+ The other values indicate the display is at a lesser intensity based
+ upon the respective percentage denoted."
+ ::= { tlpAtsDisplayEntry 4 }
+
+tlpAtsDisplayUnits OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal(0),
+ metric(1) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Indicates the units of measurement displayed on the LED display.
+ The value normal(0) indicates that a temperature value, for example,
+ is displayed in degrees Fahrenheit. The value metric(1) indicates a
+ temperature value is displayed in degrees Celsius."
+ ::= { tlpAtsDisplayEntry 5 }
+
+tlpAtsDeviceTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpAtsDeviceEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The device details of each ats in device table. This is a
+ sparse dependent table, and will contain some subset of devices
+ that are atss."
+ ::= { tlpAtsDevice 1 }
+
+tlpAtsDeviceEntry OBJECT-TYPE
+ SYNTAX TlpAtsDeviceEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing device details for a particular ats."
+ INDEX { tlpDeviceIndex }
+ ::= { tlpAtsDeviceTable 1 }
+
+TlpAtsDeviceEntry ::= SEQUENCE {
+ tlpAtsDeviceMainLoadState INTEGER,
+ tlpAtsDeviceMainLoadControllable TruthValue,
+ tlpAtsDeviceMainLoadCommand INTEGER,
+ tlpAtsDevicePowerOnDelay Integer32,
+ tlpAtsDeviceTotalInputPowerRating Integer32,
+ tlpAtsDeviceTemperatureC Integer32,
+ tlpAtsDeviceTemperatureF Integer32,
+ tlpAtsDevicePhaseImbalance INTEGER,
+ tlpAtsDeviceOutputPowerTotal Unsigned32,
+ tlpAtsDeviceAggregatePowerFactor Unsigned32,
+ tlpAtsDeviceOutputCurrentPrecision INTEGER,
+ tlpAtsDeviceGeneralFault TruthValue }
+
+tlpAtsDeviceMainLoadState OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(0),
+ off(1),
+ on(2) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current state of the main output of the device."
+ ::= { tlpAtsDeviceEntry 1 }
+
+tlpAtsDeviceMainLoadControllable OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates whether or not the main output is controllable, and whether
+ the ups can be turned off and on."
+ ::= { tlpAtsDeviceEntry 2 }
+
+tlpAtsDeviceMainLoadCommand OBJECT-TYPE
+ SYNTAX INTEGER {
+ idle(0),
+ turnOff(1),
+ turnOn(2),
+ cycle(3) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Reading this value will always return 0. Setting this value to
+ turnOff(1) will turn off the main output of the ups. Setting this
+ value to turnOn(2) will turn on the main output of the ups. Setting
+ this value to cycle(3) will turn off the main output, then turn it
+ back on."
+ ::= { tlpAtsDeviceEntry 3 }
+
+tlpAtsDevicePowerOnDelay OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The configurable delay value, which sets the amount of additional
+ time a given device will wait before it connects to a valid AC
+ source. By default the delay value is set to 0. For devices with
+ multiple AC input sources, this delay only applies to the primary
+ input source."
+ ::= { tlpAtsDeviceEntry 4 }
+
+tlpAtsDeviceTotalInputPowerRating OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "Watts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total input power rating of all phases on the device. This
+ value may not be supported on all models. If not supported, this
+ value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpAtsDeviceEntry 5 }
+
+tlpAtsDeviceTemperatureC OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "degrees Celsius"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The ambient temperature at or near the ats casing. Temperature
+ measurements are not supported on all models. If not supported,
+ this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpAtsDeviceEntry 6 }
+
+tlpAtsDeviceTemperatureF OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "degrees Fahrenheit"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The ambient temperature at or near the ats casing. Temperature
+ measurements are not supported on all models. If not supported,
+ this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpAtsDeviceEntry 7 }
+
+tlpAtsDevicePhaseImbalance OBJECT-TYPE
+ SYNTAX INTEGER (0..200)
+ UNITS "percent"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The percentage of imbalance of the three phases. This value is in
+ the range from 0% imbalance to 100% imbalance. The lower the value,
+ the better balanced the phases are. If all load is on a single phase,
+ the imbalance is defined as 100%."
+ ::= { tlpAtsDeviceEntry 8 }
+
+tlpAtsDeviceOutputPowerTotal OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "Watts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The AC output total power for all circuits."
+ ::= { tlpAtsDeviceEntry 9 }
+
+tlpAtsDeviceAggregatePowerFactor OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Watts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The aggregate power factor of all phases."
+ ::= { tlpAtsDeviceEntry 10 }
+
+tlpAtsDeviceOutputCurrentPrecision OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(0),
+ tenths(1),
+ hundredths(2) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Output current is reported by tlpAtsOutputCurrent, tlpAtsOutputCurrentMin
+ and tlpAtsOutputCurrentMax. These values are all reported in hundredths
+ (0.01A), which accommodates all models; however, on any given device the
+ actual precision may vary. This value describes the actual precision, which
+ can be used as a divisor against the output current values to obtain the
+ true output current measurement. For example, if tlpAtsOutputCurrent reports
+ 530 and tlpAtsDeviceOutputCurrentPrecision is tenths(1), then the actual
+ output current is 5.3."
+ ::= { tlpAtsDeviceEntry 11 }
+
+tlpAtsDeviceGeneralFault OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates whether or not the ats is in a system fault condition. When the
+ ats is in such a fault condition, the condition can be cleared with
+ tlpAtsControlResetGeneralFault."
+ ::= { tlpAtsDeviceEntry 12 }
+
+tlpAtsInputTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpAtsInputEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The input details of each ats in device table. This is a sparse
+ dependent table, and will contain the number of entries based upon
+ the number of atss managed by the agent as reported by tlpAtsIdentNumAts."
+ ::= { tlpAtsInput 1 }
+
+tlpAtsInputEntry OBJECT-TYPE
+ SYNTAX TlpAtsInputEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing information applicable to a particular primary
+ input phase managed by this agent."
+ INDEX { tlpDeviceIndex }
+ ::= { tlpAtsInputTable 1 }
+
+TlpAtsInputEntry ::= SEQUENCE {
+ tlpAtsInputNominalVoltage Unsigned32,
+ tlpAtsInputNominalVoltagePhaseToPhase Unsigned32,
+ tlpAtsInputNominalVoltagePhaseToNeutral Unsigned32,
+ tlpAtsInputBadTransferVoltage Unsigned32,
+ tlpAtsInputBadTransferVoltageLowerBound Unsigned32,
+ tlpAtsInputBadTransferVoltageUpperBound Unsigned32,
+ tlpAtsInputHighTransferVoltage Unsigned32,
+ tlpAtsInputHighTransferVoltageLowerBound Unsigned32,
+ tlpAtsInputHighTransferVoltageUpperBound Unsigned32,
+ tlpAtsInputFairVoltageThreshold Unsigned32,
+ tlpAtsInputBadVoltageThreshold Unsigned32,
+ tlpAtsInputSourceAvailability INTEGER,
+ tlpAtsInputSourceInUse INTEGER,
+ tlpAtsInputSourceTransitionCount Unsigned32,
+ tlpAtsInputCurrentLimit Unsigned32 }
+
+tlpAtsInputNominalVoltage OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The nominal value of the input line voltage. This value may not
+ be supported on all models. If not supported, this value will return
+ ERROR_NO_SUCH_NAME."
+ ::= { tlpAtsInputEntry 1 }
+
+tlpAtsInputNominalVoltagePhaseToPhase OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Volts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The nominal value of the input line voltage as measured from
+ phase to phase. This value may not be supported on all models.
+ If not supported, this value will always return zero."
+ ::= { tlpAtsInputEntry 2 }
+
+tlpAtsInputNominalVoltagePhaseToNeutral OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Volts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The nominal value of the input line voltage as measured from
+ phase to neutral. This value may not be supported on all models.
+ If not supported, this value will always return zero."
+ ::= { tlpAtsInputEntry 3 }
+
+tlpAtsInputBadTransferVoltage OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Volts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The minimum line voltage allowed before the unit disconnects the
+ AC input connection."
+ ::= { tlpAtsInputEntry 4 }
+
+tlpAtsInputBadTransferVoltageLowerBound OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "Volts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The lower boundary value of tlpAtsInputBadTransferVoltage as dictated
+ by the hardware of the unit."
+ ::= { tlpAtsInputEntry 5 }
+
+tlpAtsInputBadTransferVoltageUpperBound OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "Volts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The upper boundary value of tlpAtsInputBadTransferVoltage as dictated
+ by the hardware of the unit."
+ ::= { tlpAtsInputEntry 6 }
+
+tlpAtsInputHighTransferVoltage OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Volts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The maximum line voltage allowed before the unit disconnects the
+ AC input connection."
+ ::= { tlpAtsInputEntry 7 }
+
+tlpAtsInputHighTransferVoltageLowerBound OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "Volts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The lower boundary value of tlpAtsInputHighTransferVoltage as dictated
+ by the hardware of the unit."
+ ::= { tlpAtsInputEntry 8 }
+
+tlpAtsInputHighTransferVoltageUpperBound OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "Volts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The upper boundary value of tlpAtsInputHighTransferVoltage as dictated
+ by the hardware of the unit."
+ ::= { tlpAtsInputEntry 9 }
+
+tlpAtsInputFairVoltageThreshold OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "Volts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The voltage level at which the device will transition between sources."
+ ::= { tlpAtsInputEntry 10 }
+
+tlpAtsInputBadVoltageThreshold OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "Volts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The minimum line voltage allowed before the device disconnects the AC input
+ connection."
+ ::= { tlpAtsInputEntry 11 }
+
+tlpAtsInputSourceAvailability OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(0),
+ inputSourceA(1),
+ inputSourceB(2),
+ inputSourceAB(3) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The determination as to which of two AC input lines are available.
+ The agent will return either inputSourceA(1) or inputSourceB(2) if
+ only one line is available, or inputSourceAB(3) if both lines are
+ available. The agent will never return none(0) since the device will
+ be powered off if neither line is available."
+ ::= { tlpAtsInputEntry 12 }
+
+tlpAtsInputSourceInUse OBJECT-TYPE
+ SYNTAX INTEGER {
+ inputSourceA(0),
+ inputSourceB(1) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The determination as to which one of two AC input lines is in use. Not all
+ devices support the reporting of which source is currently in use. If not
+ supported, this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpAtsInputEntry 13 }
+
+tlpAtsInputSourceTransitionCount OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of times the device transitions between primary and secondary
+ sources. Most devices are limited to 65533 transitions, after which the
+ value will not increment. If not supported, this value will always return
+ ERROR_NO_SUCH_NAME."
+ ::= { tlpAtsInputEntry 14 }
+
+tlpAtsInputCurrentLimit OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "Amps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The capacity of each phase conductor in the ats limited by the AC input
+ cord or any other potential limiting factors unique to a given unit. If not
+ supported, this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpAtsInputEntry 15 }
+
+tlpAtsInputPhaseTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpAtsInputPhaseEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The input phase details of each ats in device table. This is a sparse
+ dependent table, and will contain the number of entries based upon
+ the value of tlpAtsIdentNumInputs and tlpAtsIdentNumPhases per each
+ device."
+ ::= { tlpAtsInput 2 }
+
+tlpAtsInputPhaseEntry OBJECT-TYPE
+ SYNTAX TlpAtsInputPhaseEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing information applicable to a particular primary
+ input phase managed by this agent."
+ INDEX { tlpDeviceIndex, tlpAtsInputLineIndex, tlpAtsInputPhaseIndex }
+ ::= { tlpAtsInputPhaseTable 1 }
+
+TlpAtsInputPhaseEntry ::= SEQUENCE {
+ tlpAtsInputLineIndex Unsigned32,
+ tlpAtsInputPhaseIndex Unsigned32,
+ tlpAtsInputPhaseType INTEGER,
+ tlpAtsInputPhaseFrequency Unsigned32,
+ tlpAtsInputPhaseVoltage Unsigned32,
+ tlpAtsInputPhaseVoltageMin Unsigned32,
+ tlpAtsInputPhaseVoltageMax Unsigned32,
+ tlpAtsInputPhaseCurrent Unsigned32 }
+
+tlpAtsInputLineIndex OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The table row index for the input line on the ats."
+ ::= { tlpAtsInputPhaseEntry 1 }
+
+tlpAtsInputPhaseIndex OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The table row index for the input phase for the input line."
+ ::= { tlpAtsInputPhaseEntry 2 }
+
+tlpAtsInputPhaseType OBJECT-TYPE
+ SYNTAX INTEGER {
+ phaseToNeutral(0),
+ phaseToPhase(1) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Denotes whether measurements are phase to neutral(0) or phase
+ to phase(1)."
+ ::= { tlpAtsInputPhaseEntry 3 }
+
+tlpAtsInputPhaseFrequency OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Hertz"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The present input frequency for a given phase."
+ ::= { tlpAtsInputPhaseEntry 4 }
+
+tlpAtsInputPhaseVoltage OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Volts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The magnitude of the present input voltage for a given phase."
+ ::= { tlpAtsInputPhaseEntry 5 }
+
+tlpAtsInputPhaseVoltageMin OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Volts"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The minimum input voltage value since the last reset of this
+ value for a given phase. If any value is written to either
+ tlpAtsInputVoltageMin or tlpAtsInputVoltageMax, both
+ will be reset to their appropriate minimum and maximum values."
+ ::= { tlpAtsInputPhaseEntry 6 }
+
+tlpAtsInputPhaseVoltageMax OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Volts"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The maximum input voltage value since the last reset of this
+ value for a given phase. If any value is written to either
+ tlpAtsInputVoltageMin or tlpAtsInputVoltageMax, both
+ will be reset to their appropriate minimum and maximum values."
+ ::= { tlpAtsInputPhaseEntry 7 }
+
+tlpAtsInputPhaseCurrent OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.01 Amps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The magnitude of the present input current for a given phase."
+ ::= { tlpAtsInputPhaseEntry 8 }
+
+tlpAtsOutputTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpAtsOutputEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The output details of each ats in device table. This is a sparse
+ dependent table, and will contain the number of entries based upon
+ the value of tlpAtsIdentNumOutputs per each device."
+ ::= { tlpAtsOutput 1 }
+
+tlpAtsOutputEntry OBJECT-TYPE
+ SYNTAX TlpAtsOutputEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing output information applicable to a particular
+ phase managed by this agent."
+ INDEX { tlpDeviceIndex, tlpAtsOutputIndex }
+ ::= { tlpAtsOutputTable 1 }
+
+TlpAtsOutputEntry ::= SEQUENCE {
+ tlpAtsOutputIndex Unsigned32,
+ tlpAtsOutputPhase INTEGER,
+ tlpAtsOutputPhaseType INTEGER,
+ tlpAtsOutputVoltage Unsigned32,
+ tlpAtsOutputCurrent Unsigned32,
+ tlpAtsOutputCurrentMin Unsigned32,
+ tlpAtsOutputCurrentMax Unsigned32,
+ tlpAtsOutputActivePower Unsigned32,
+ tlpAtsOutputPowerFactor Unsigned32,
+ tlpAtsOutputSource INTEGER,
+ tlpAtsOutputFrequency Unsigned32,
+ tlpAtsOutputCalculatedPowerKVA Unsigned32,
+ tlpAtsOutputCalculatedPowerKW Unsigned32,
+ tlpAtsOutputCalculated24hrEnergy Unsigned32 }
+
+tlpAtsOutputIndex OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The table row index for the ats phase."
+ ::= { tlpAtsOutputEntry 1 }
+
+tlpAtsOutputPhase OBJECT-TYPE
+ SYNTAX INTEGER {
+ phase1(1),
+ phase2(2),
+ phase3(3) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the phase associated with the output line."
+ ::= { tlpAtsOutputEntry 2 }
+
+tlpAtsOutputPhaseType OBJECT-TYPE
+ SYNTAX INTEGER {
+ phaseToNeutral(0),
+ phaseToPhase(1) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Denotes whether measurements are phase to neutral(0) or phase
+ to phase(1)."
+ ::= { tlpAtsOutputEntry 3 }
+
+tlpAtsOutputVoltage OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Volts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The magnitude of the present output voltage for a given output line."
+ ::= { tlpAtsOutputEntry 4 }
+
+tlpAtsOutputCurrent OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.01 Amps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The output current, in hundredths of amps, for a given phase.
+ The actual precision of this value, whether a whole number, tenths
+ or hundredths, is returned by tlpAtsDeviceOutputCurrentPrecision."
+ ::= { tlpAtsOutputEntry 5 }
+
+tlpAtsOutputCurrentMin OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.01 Amps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The minimum current, in hundredths of amps, observed for a given phase
+ since last reset. The actual precision of this value, whether a whole number,
+ tenths or hundredths, is returned by tlpAtsDeviceOutputCurrentPrecision."
+ ::= { tlpAtsOutputEntry 6 }
+
+tlpAtsOutputCurrentMax OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.01 Amps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The maximum current, in hundredths of amps, observed for a given phase
+ since last reset. The actual precision of this value, whether a whole number,
+ tenths or hundredths, is returned by tlpAtsDeviceOutputCurrentPrecision."
+ ::= { tlpAtsOutputEntry 7 }
+
+tlpAtsOutputActivePower OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "Watts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The output power for a given phase."
+ ::= { tlpAtsOutputEntry 8 }
+
+tlpAtsOutputPowerFactor OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.01 percent"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The output power factor, in hundredths of a percent, for a given
+ phase."
+ ::= { tlpAtsOutputEntry 9 }
+
+tlpAtsOutputSource OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(0),
+ normal(1) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The present source of output power. The enumeration none(0)
+ indicates that there is no source of output power (and
+ therefore no output power), for example, the system has opened
+ the output breaker."
+ ::= { tlpAtsOutputEntry 10 }
+
+tlpAtsOutputFrequency OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Hertz"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The present output frequency. If not supported, the agent reports ERROR_NO_SUCH_NAME."
+ ::= { tlpAtsOutputEntry 11 }
+
+tlpAtsOutputCalculatedPowerKVA OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.01 KVA"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The calculated amount of apparent power being used."
+ ::= { tlpAtsOutputEntry 12 }
+
+tlpAtsOutputCalculatedPowerKW OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.01 KW"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The calculated amount of active power being used."
+ ::= { tlpAtsOutputEntry 13 }
+
+tlpAtsOutputCalculated24hrEnergy OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.01 KWH"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Estimated 24 hour power consumption using present value
+ of tlpAtsOutputCalculatedPowerKW."
+ ::= { tlpAtsOutputEntry 14 }
+
+tlpAtsOutletTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpAtsOutletEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The receptacle status details of each ats in device table. This
+ is a sparse dependent table, and will contain the number of entries
+ based upon the value of tlpAtsIdentNumOutlets per each device."
+ ::= { tlpAtsOutlet 1 }
+
+tlpAtsOutletEntry OBJECT-TYPE
+ SYNTAX TlpAtsOutletEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing information applicable to a particular outlet
+ managed by this agent."
+ INDEX { tlpDeviceIndex, tlpAtsOutletIndex }
+ ::= { tlpAtsOutletTable 1 }
+
+TlpAtsOutletEntry ::= SEQUENCE {
+ tlpAtsOutletIndex Unsigned32,
+ tlpAtsOutletName DisplayString,
+ tlpAtsOutletDescription DisplayString,
+ tlpAtsOutletState INTEGER,
+ tlpAtsOutletControllable TruthValue,
+ tlpAtsOutletCommand INTEGER,
+ tlpAtsOutletVoltage Unsigned32,
+ tlpAtsOutletCurrent Unsigned32,
+ tlpAtsOutletPower Unsigned32,
+ tlpAtsOutletRampAction INTEGER,
+ tlpAtsOutletRampDelay Integer32,
+ tlpAtsOutletShedAction INTEGER,
+ tlpAtsOutletShedDelay Integer32,
+ tlpAtsOutletGroup Integer32,
+ tlpAtsOutletBank Integer32,
+ tlpAtsOutletCircuit Integer32,
+ tlpAtsOutletPhase INTEGER }
+
+tlpAtsOutletIndex OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The table row index for the ats outlet."
+ ::= { tlpAtsOutletEntry 1 }
+
+tlpAtsOutletName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A user-definable string identifying the name of the outlet."
+ ::= { tlpAtsOutletEntry 2 }
+
+tlpAtsOutletDescription OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A user-definable string identifying the device(s) connected to
+ the given outlet."
+ ::= { tlpAtsOutletEntry 3 }
+
+tlpAtsOutletState OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(0),
+ off(1),
+ on(2) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current state of the outlet."
+ ::= { tlpAtsOutletEntry 4 }
+
+tlpAtsOutletControllable OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Denotes whether this outlet is controllable."
+ ::= { tlpAtsOutletEntry 5 }
+
+tlpAtsOutletCommand OBJECT-TYPE
+ SYNTAX INTEGER {
+ idle(0),
+ turnOff(1),
+ turnOn(2),
+ cycle(3) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Reading this value will always return 0. Setting this value
+ to turnOff(1) will turn off the outlet. Setting this value
+ to turnOn(2) will turn on the outlet. Setting this value to
+ cycle(3) will turn the outlet off, then turn it back on."
+ ::= { tlpAtsOutletEntry 6 }
+
+tlpAtsOutletVoltage OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Volts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The magnitude of the present output voltage for a given outlet.
+ If the voltage measurement is not supported for an individual
+ receptacle regardless whether device-wide or just for this
+ receptacle, then this value will always return ERROR_NO_SUCH_NAME.
+ Device-wide support for receptacle voltage measurements is denoted
+ by tlpAtsSupportsOutletVoltage."
+ ::= { tlpAtsOutletEntry 7 }
+
+tlpAtsOutletCurrent OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.01 Amps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The present output current, in hundredths of amps, of a given outlet.
+ If the current measurement is not supported for an individual
+ receptacle regardless whether device-wide or just for this
+ receptacle, then this value will always return ERROR_NO_SUCH_NAME.
+ Device-wide support for receptacle current measurements is denoted
+ by tlpAtsSupportsCurrentPower."
+ ::= { tlpAtsOutletEntry 8 }
+
+tlpAtsOutletPower OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "Watts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The output power of a given outlet. If the power measurement is
+ not supported for an individual receptacle regardless whether
+ device-wide or just for this receptacle, then this value will
+ always return ERROR_NO_SUCH_NAME. Device-wide support for receptacle
+ power measurements is denoted by tlpAtsSupportsCurrentPower."
+ ::= { tlpAtsOutletEntry 9 }
+
+tlpAtsOutletRampAction OBJECT-TYPE
+ SYNTAX INTEGER {
+ remainOff(0),
+ turnOnAfterDelay(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The ramp action to take on a given outlet when powering on the
+ device. If this receptacle is not controllable, as denoted by
+ tlpAtsOutletControllable, then this value will always return
+ ERROR_NO_SUCH_NAME."
+ ::= { tlpAtsOutletEntry 10 }
+
+tlpAtsOutletRampDelay OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "seconds"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The number of seconds to delay before powering on the given outlet.
+ If this receptacle is not controllable, as denoted by
+ tlpAtsOutletControllable, then this value will always return
+ ERROR_NO_SUCH_NAME."
+ ::= { tlpAtsOutletEntry 11 }
+
+tlpAtsOutletShedAction OBJECT-TYPE
+ SYNTAX INTEGER {
+ remainOn(0),
+ turnOffAfterDelay(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The shed action to take on a given outlet when powering off the
+ device. If this receptacle is not controllable, as denoted by
+ tlpAtsOutletControllable, then this value will always return
+ ERROR_NO_SUCH_NAME."
+ ::= { tlpAtsOutletEntry 12 }
+
+tlpAtsOutletShedDelay OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "seconds"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The number of seconds to delay before powering off the given outlet.
+ If this receptacle is not controllable, as denoted by
+ tlpAtsOutletControllable, then this value will always return
+ ERROR_NO_SUCH_NAME."
+ ::= { tlpAtsOutletEntry 13 }
+
+tlpAtsOutletGroup OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The tlpAtsOutletGroupIndex group index of the respective group to
+ which the given outlet is assigned, or zero (0) if the given
+ outlet is not grouped."
+ ::= { tlpAtsOutletEntry 14 }
+
+tlpAtsOutletBank OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates on which bank the given outlet is located."
+ ::= { tlpAtsOutletEntry 15 }
+
+tlpAtsOutletCircuit OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates on which circuit the given outlet is wired."
+ ::= { tlpAtsOutletEntry 16 }
+
+tlpAtsOutletPhase OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(0),
+ phase1(1),
+ phase2(2),
+ phase3(3),
+ phase1-2(4),
+ phase2-3(5),
+ phase3-1(6) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates on which phase or phases the given outlet is
+ associated. For single phase devices, this object will
+ always return phase1(1). For 3-phase devices with outlets
+ wired to a single phase, this object will return phase1(1),
+ phase2(2) or phase3(3). For 3-phase devices with outlets
+ wired to two phases, this object will return phase1-2(4)
+ for phases 1 and 2, phase2-3(5) for phases 2 and 3, and
+ phase3-1(6) for phases 3 and 1. Devices that do not report
+ phase connections will return unknown(0)."
+ ::= { tlpAtsOutletEntry 17 }
+
+tlpAtsOutletGroupTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpAtsOutletGroupEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The receptacle grouping details of each ats in device table.
+ This is a sparse dependent table, and will contain the number
+ of entries based upon the value of tlpAtsIdentNumOutletGroups per
+ each device."
+ ::= { tlpAtsOutlet 2 }
+
+tlpAtsOutletGroupEntry OBJECT-TYPE
+ SYNTAX TlpAtsOutletGroupEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing information applicable to a particular outlet
+ group managed by this agent."
+ INDEX { tlpDeviceIndex, tlpAtsOutletGroupIndex }
+ ::= { tlpAtsOutletGroupTable 1 }
+
+TlpAtsOutletGroupEntry ::= SEQUENCE {
+ tlpAtsOutletGroupIndex Unsigned32,
+ tlpAtsOutletGroupRowStatus RowStatus,
+ tlpAtsOutletGroupName DisplayString,
+ tlpAtsOutletGroupDescription DisplayString,
+ tlpAtsOutletGroupState INTEGER,
+ tlpAtsOutletGroupCommand INTEGER }
+
+tlpAtsOutletGroupIndex OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The table row index for the ats outlet group."
+ ::= { tlpAtsOutletGroupEntry 1 }
+
+tlpAtsOutletGroupRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Row status for the tlpAtsOutletGroupTable"
+ ::= { tlpAtsOutletGroupEntry 2 }
+
+tlpAtsOutletGroupName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The name of this outlet group."
+ ::= { tlpAtsOutletGroupEntry 3 }
+
+tlpAtsOutletGroupDescription OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A description for this outlet group."
+ ::= { tlpAtsOutletGroupEntry 4 }
+
+tlpAtsOutletGroupState OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(0),
+ off(1),
+ on(2),
+ mixed(3) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current state of the outlet group. This value will report
+ off(1) if all outlets in the group are off, on(2) if all outlets
+ in the group are on, mixed(3) if some outlets in the group are
+ off and others are on, or unknown(0) if the state of the outlets
+ cannot be determined."
+ ::= { tlpAtsOutletGroupEntry 5 }
+
+tlpAtsOutletGroupCommand OBJECT-TYPE
+ SYNTAX INTEGER {
+ turnOff(1),
+ turnOn(2),
+ cycle(3) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Reading this value will always return 0. Setting this value to
+ turnOff(1) will turn off every outlet associated with the group.
+ Setting this value to turnOn(2) will turn on every outlet associated
+ with the group. Setting this value to cycle(3) will turn off every
+ outlet associated with the group, then turn each outlet back on."
+ ::= { tlpAtsOutletGroupEntry 6 }
+
+tlpAtsCircuitTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpAtsCircuitEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of ats circuit table entries. The number of entries
+ is given by the value of tlpAtsIdentNumCircuits."
+ ::= { tlpAtsCircuit 1 }
+
+tlpAtsCircuitEntry OBJECT-TYPE
+ SYNTAX TlpAtsCircuitEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing information applicable to a particular circuit
+ managed by this agent."
+ INDEX { tlpDeviceIndex, tlpAtsCircuitIndex }
+ ::= { tlpAtsCircuitTable 1 }
+
+TlpAtsCircuitEntry ::= SEQUENCE {
+ tlpAtsCircuitIndex Unsigned32,
+ tlpAtsCircuitPhase INTEGER,
+ tlpAtsCircuitInputVoltage Integer32,
+ tlpAtsCircuitTotalCurrent Integer32,
+ tlpAtsCircuitCurrentLimit Integer32,
+ tlpAtsCircuitCurrentMin Integer32,
+ tlpAtsCircuitCurrentMax Integer32,
+ tlpAtsCircuitTotalPower Integer32,
+ tlpAtsCircuitPowerFactor INTEGER,
+ tlpAtsCircuitUtilization Unsigned32 }
+
+tlpAtsCircuitIndex OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The table row index for the ats circuit."
+ ::= { tlpAtsCircuitEntry 1 }
+
+tlpAtsCircuitPhase OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(0),
+ phase1(1),
+ phase2(2),
+ phase3(3),
+ phase1-2(4),
+ phase2-3(5),
+ phase3-1(6) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates on which phase or phases the given circuit is
+ wired. For single phase devices, this object will always
+ return phase1(1). For 3-phase devices with outlets wired
+ to a single phase, this object will return phase1(1),
+ phase2(2) or phase3(3). For 3-phase devices with outlets
+ wired to two phases, this object will return phase1-2(4)
+ for phases 1 and 2, phase2-3(5) for phases 2 and 3, and
+ phase3-1(6) for phases 3 and 1. Devices that do not report
+ phase connections will return unknown(0)."
+ ::= { tlpAtsCircuitEntry 2 }
+
+tlpAtsCircuitInputVoltage OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 Volts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The input voltage for a circuit."
+ ::= { tlpAtsCircuitEntry 3 }
+
+tlpAtsCircuitTotalCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.01 Amps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total current for all receptacles in a given circuit."
+ ::= { tlpAtsCircuitEntry 4 }
+
+tlpAtsCircuitCurrentLimit OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.01 Amps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current capacity of a circuit in the system limited by
+ the circuit breaker or wiring used in a given unit."
+ ::= { tlpAtsCircuitEntry 5 }
+
+tlpAtsCircuitCurrentMin OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.01 Amps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The minimum total current for all receptacles in a given
+ circuit since last reset."
+ ::= { tlpAtsCircuitEntry 6 }
+
+tlpAtsCircuitCurrentMax OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.01 Amps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The maximum total current for all receptacles in a given
+ circuit since last reset."
+ ::= { tlpAtsCircuitEntry 7 }
+
+tlpAtsCircuitTotalPower OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "Watts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total power for all receptacles in a given circuit."
+ ::= { tlpAtsCircuitEntry 8 }
+
+tlpAtsCircuitPowerFactor OBJECT-TYPE
+ SYNTAX INTEGER (0..200)
+ UNITS "percent"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The power factor for all receptacles in a given circuit."
+ ::= { tlpAtsCircuitEntry 9 }
+
+tlpAtsCircuitUtilization OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.01 percent"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The percentage of utilization of a given circuit. This is typically
+ a calculation of tlpAtsCircuitTotalCurrent / tlpAtsCircuitCurrentLimit."
+ ::= { tlpAtsCircuitEntry 10 }
+
+tlpAtsBreakerTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpAtsBreakerEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of ats bank breaker table entries. The number of entries
+ is given by the value of tlpAtsIdentNumBreakers."
+ ::= { tlpAtsBreaker 1 }
+
+tlpAtsBreakerEntry OBJECT-TYPE
+ SYNTAX TlpAtsBreakerEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing information applicable to a particular bank
+ breaker managed by this agent."
+ INDEX { tlpDeviceIndex, tlpAtsBreakerIndex }
+ ::= { tlpAtsBreakerTable 1 }
+
+TlpAtsBreakerEntry ::= SEQUENCE {
+ tlpAtsBreakerIndex Unsigned32,
+ tlpAtsBreakerStatus INTEGER }
+
+tlpAtsBreakerIndex OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The table row index for the ats bank breaker."
+ ::= { tlpAtsBreakerEntry 1 }
+
+tlpAtsBreakerStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ open(0),
+ closed(1),
+ notInstalled(2) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates whether the bank breaker is open(0), closed(1) or not
+ installed(2)."
+ ::= { tlpAtsBreakerEntry 2 }
+
+tlpAtsHeatsinkTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpAtsHeatsinkEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of ats heatsink thermistor table entries. The number of entries
+ is given by the value of tlpAtsIdentNumHeatsinks."
+ ::= { tlpAtsHeatsink 1 }
+
+tlpAtsHeatsinkEntry OBJECT-TYPE
+ SYNTAX TlpAtsHeatsinkEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing information applicable to a particular heatsink
+ thermistor managed by this agent."
+ INDEX { tlpDeviceIndex, tlpAtsHeatsinkIndex }
+ ::= { tlpAtsHeatsinkTable 1 }
+
+TlpAtsHeatsinkEntry ::= SEQUENCE {
+ tlpAtsHeatsinkIndex Unsigned32,
+ tlpAtsHeatsinkStatus INTEGER,
+ tlpAtsHeatsinkTemperatureC Integer32,
+ tlpAtsHeatsinkTemperatureF Integer32 }
+
+tlpAtsHeatsinkIndex OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The table row index for the ats heatsink thermistor."
+ ::= { tlpAtsHeatsinkEntry 1 }
+
+tlpAtsHeatsinkStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ notAvailable(0),
+ available(1) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates whether the heatsink thermistor is available. The entry
+ will return notAvailable(0) if a thermistor is either non-existent or
+ disconnected, or available(1) when connected."
+ ::= { tlpAtsHeatsinkEntry 2 }
+
+tlpAtsHeatsinkTemperatureC OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 degrees Celsius"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The temperature at the heatsink thermistor in tenths degrees Celsius.
+ Heatsink temperature measurements are not supported on all models. If
+ not supported, this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpAtsHeatsinkEntry 3 }
+
+tlpAtsHeatsinkTemperatureF OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 degrees Fahrenheit"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The temperature at the heatsink thermistor in tenths degrees Fahrenheit.
+ Heatsink temperature measurements are not supported on all models. If
+ not supported, this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpAtsHeatsinkEntry 4 }
+
+tlpAtsControlTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpAtsControlEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The actionable controls for each ats in device table. This is a
+ sparse dependent table, and will contain some subset of devices
+ that are atss."
+ ::= { tlpAtsControl 1 }
+
+tlpAtsControlEntry OBJECT-TYPE
+ SYNTAX TlpAtsControlEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing controls for a particular ats."
+ INDEX { tlpDeviceIndex }
+ ::= { tlpAtsControlTable 1 }
+
+TlpAtsControlEntry ::= SEQUENCE {
+ tlpAtsControlRamp TruthValue,
+ tlpAtsControlShed TruthValue,
+ tlpAtsControlAtsOn TruthValue,
+ tlpAtsControlAtsOff TruthValue,
+ tlpAtsControlAtsReboot TruthValue,
+ tlpAtsControlResetGeneralFault TruthValue }
+
+tlpAtsControlRamp OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Set to TRUE to initiate the pre-designated ramp
+ sequence on the ats."
+ ::= { tlpAtsControlEntry 1 }
+
+tlpAtsControlShed OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Set to TRUE to initiate the pre-designated shed
+ sequence on the ats."
+ ::= { tlpAtsControlEntry 2 }
+
+tlpAtsControlAtsOn OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Set to TRUE to turn the ats on."
+ ::= { tlpAtsControlEntry 3 }
+
+tlpAtsControlAtsOff OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Set to TRUE to turn the ats off."
+ ::= { tlpAtsControlEntry 4 }
+
+tlpAtsControlAtsReboot OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Set to TRUE to reboot the ats."
+ ::= { tlpAtsControlEntry 5 }
+
+tlpAtsControlResetGeneralFault OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Set to TRUE to reset the general fault alarm indicated by
+ tlpAtsDeviceGeneralFault."
+ ::= { tlpAtsControlEntry 6 }
+
+tlpAtsConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpAtsConfigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The configuration options of each ats in device table. This
+ is a sparse dependent table, and will contain some subset of
+ devices that are atss. Not all options are available on all
+ atss."
+ ::= { tlpAtsConfig 1 }
+
+tlpAtsConfigEntry OBJECT-TYPE
+ SYNTAX TlpAtsConfigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing configuration options for a particular ats."
+ INDEX { tlpDeviceIndex }
+ ::= { tlpAtsConfigTable 1 }
+
+TlpAtsConfigEntry ::= SEQUENCE {
+ tlpAtsConfigInputVoltage Unsigned32,
+ tlpAtsConfigSourceSelect INTEGER,
+ tlpAtsConfigSource1ReturnTime Unsigned32,
+ tlpAtsConfigSource2ReturnTime Unsigned32,
+ tlpAtsConfigAutoRampOnTransition INTEGER,
+ tlpAtsConfigAutoShedOnTransition INTEGER }
+
+tlpAtsConfigInputVoltage OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The nominal value of the input line voltage. This value may not
+ be supported on all models. If not supported, this value will return
+ ERROR_NO_SUCH_NAME. This value may not be writable on all models. If
+ not writable, the value will be rejected and an appropriate error
+ message will be returned."
+ ::= { tlpAtsConfigEntry 1 }
+
+tlpAtsConfigSourceSelect OBJECT-TYPE
+ SYNTAX INTEGER {
+ inputSourceA(1),
+ inputSourceB(2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The determination as to which of two AC input lines is designated
+ as the primary input source. The other is designated as the
+ secondary input source. This value will always return inputSourceA(1)
+ for devices with a single input source. Setting this value is
+ supported only on selected models."
+ ::= { tlpAtsConfigEntry 2 }
+
+tlpAtsConfigSource1ReturnTime OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The nominal time to delay a transition to Source 1, if it is the
+ preferred source."
+ ::= { tlpAtsConfigEntry 3 }
+
+tlpAtsConfigSource2ReturnTime OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The nominal time to delay a transition to Source 2, if it is the
+ preferred source."
+ ::= { tlpAtsConfigEntry 4 }
+
+tlpAtsConfigAutoRampOnTransition OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "When enabled(1), the ats should perform its preconfigured ramp sequence when
+ the input source transfers from its designated secondary source to its
+ designated primary source. This value not supported on all ats devices. If not
+ supported, then this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpAtsConfigEntry 5 }
+
+tlpAtsConfigAutoShedOnTransition OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "When enabled(1), the ats should perform its preconfigured shed sequence when
+ the input source transfers from its designated primary source to its designated
+ secondary source. This value not supported on all ats devices. If not supported,
+ then this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpAtsConfigEntry 6 }
+
+tlpAtsConfigVoltageRangeOldTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpAtsConfigVoltageRangeOldEntry
+ MAX-ACCESS not-accessible
+ STATUS obsolete
+ DESCRIPTION
+ "The voltage range options in this table is intended to configure the
+ operating voltages of an ats. This is a sparse dependent table, and will
+ contain some subset of devices that are atss. All voltage points defined
+ in this table are listed in a specific order from high to low. All voltage
+ points must satisfy the conditions and ranges defined for each point. Any
+ point violating any of the relative limits will be rejected.
+
+ For optimal operation, it is recommended that tlpAtsConfigHighVoltageReset
+ be set lower than tlpAtsConfigHighVoltageTransfer by a margin no less than 1%
+ of tlpAtsConfigHighVoltageTransfer; and that tlpAtsConfigSource1TransferReset
+ (tlpAtsConfigSource2TransferReset) be set higher than
+ tlpAtsConfigSource1BrownoutSet (tlpAtsConfigSource2BrownoutSet) by a margin no
+ less than 1% of tlpAtsConfigSource1BrownoutSet (tlpAtsConfigSource2BrownoutSet).
+
+ *The upper limit of line voltage is tlpAtsInputHighTransferVoltageUpperBound.
+ The lower limit of line voltage is tlpAtsInputBadTransferVoltageLowerBound. All
+ minimum and maximum limits for each voltage point are all exclusive unless
+ indicated otherwise.
+
+ This table in its entirety is obsolete and replaced by tlpAtsConfigVoltageRangeTable."
+ ::= { tlpAtsConfig 2 }
+
+tlpAtsConfigVoltageRangeOldEntry OBJECT-TYPE
+ SYNTAX TlpAtsConfigVoltageRangeOldEntry
+ MAX-ACCESS not-accessible
+ STATUS obsolete
+ DESCRIPTION
+ "An entry containing voltage range configuration options for a particular ats."
+ INDEX { tlpDeviceIndex }
+ ::= { tlpAtsConfigVoltageRangeOldTable 1 }
+
+TlpAtsConfigVoltageRangeOldEntry ::= SEQUENCE {
+ tlpAtsConfigHighVoltageTransferOld Unsigned32,
+ tlpAtsConfigHighVoltageResetOld Unsigned32,
+ tlpAtsConfigSource1TransferResetOld Unsigned32,
+ tlpAtsConfigSource1BrownoutSetOld Unsigned32,
+ tlpAtsConfigSource1TransferSetOld Unsigned32,
+ tlpAtsConfigSource2TransferResetOld Unsigned32,
+ tlpAtsConfigSource2BrownoutSetOld Unsigned32,
+ tlpAtsConfigSource2TransferSetOld Unsigned32,
+ tlpAtsConfigLowVoltageResetOld Unsigned32,
+ tlpAtsConfigLowVoltageTransferOld Unsigned32 }
+
+tlpAtsConfigHighVoltageTransferOld OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Volts"
+ MAX-ACCESS read-write
+ STATUS obsolete
+ DESCRIPTION
+ "The maximum line voltage allowed before the unit disconnects the
+ AC input connection. The maximum value allowed is dictated by
+ tlpAtsInputHighTransferVoltageUpperBound (inclusively). The minimum
+ value allowed is dictated by tlpAtsConfigHighVoltageResetOld. This value
+ may not be configurable on all models. If not supported, this value will
+ return ERROR_NO_SUCH_NAME."
+ ::= { tlpAtsConfigVoltageRangeOldEntry 1 }
+
+tlpAtsConfigHighVoltageResetOld OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Volts"
+ MAX-ACCESS read-write
+ STATUS obsolete
+ DESCRIPTION
+ "If a unit is disconnected due to over-voltage, the line voltage has to
+ fall below this value before the unit re-connects the AC input connection.
+ The maximum value allowed is dictated by tlpAtsConfigHighVoltageTransferOld.
+ The minimum value allowed is dictated by the greater of
+ tlpAtsConfigSource1TransferResetOld and tlpAtsConfigSource2TransferResetOld. If
+ not supported, this value will return ERROR_NO_SUCH_NAME."
+ ::= { tlpAtsConfigVoltageRangeOldEntry 2 }
+
+tlpAtsConfigSource1TransferResetOld OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Volts"
+ MAX-ACCESS read-write
+ STATUS obsolete
+ DESCRIPTION
+ "If input source 1 voltage level is above this value, a unit connected to
+ source 2 will transition to source 1 (if it is the preferred source). The
+ maximum value allowed is dictated by tlpAtsConfigHighVoltageResetOld. The
+ minimum value allowed is dictated by tlpAtsConfigSource1BrownoutSetOld. If not
+ supported, this value will return ERROR_NO_SUCH_NAME."
+ ::= { tlpAtsConfigVoltageRangeOldEntry 3 }
+
+tlpAtsConfigSource1BrownoutSetOld OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Volts"
+ MAX-ACCESS read-write
+ STATUS obsolete
+ DESCRIPTION
+ "This value dictates the voltage level below which source 1 goes into a
+ brown out condition. The maximum value allowed is dictated by
+ tlpAtsConfigSource1TransferResetOld. The minimum value allowed is dictated by
+ tlpAtsConfigSource1TransferSetOld. If not supported, this value will return
+ ERROR_NO_SUCH_NAME."
+ ::= { tlpAtsConfigVoltageRangeOldEntry 4 }
+
+tlpAtsConfigSource1TransferSetOld OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Volts"
+ MAX-ACCESS read-write
+ STATUS obsolete
+ DESCRIPTION
+ "If input source 1 voltage level falls below this value, a unit connected to
+ source 1 will transition to source 2 (if it is in fair condition as denoted
+ by tlpAtsConfigSource2TransferSetOld). The maximum value allowed is dictated by
+ tlpAtsConfigSource1BrownoutSetOld. The minimum value allowed is dictated by
+ tlpAtsConfigLowVoltageResetOld. If not supported, this value will return
+ ERROR_NO_SUCH_NAME."
+ ::= { tlpAtsConfigVoltageRangeOldEntry 5 }
+
+tlpAtsConfigSource2TransferResetOld OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Volts"
+ MAX-ACCESS read-write
+ STATUS obsolete
+ DESCRIPTION
+ "If input source 2 voltage level is above this value, a unit connected to
+ source 1 will transition to source 2 (if it is the preferred source). The
+ maximum value allowed is dictated by tlpAtsConfigHighVoltageResetOld. The
+ minimum value allowed is dictated by tlpAtsConfigSource2BrownoutSetOld. If not
+ supported, this value will return ERROR_NO_SUCH_NAME."
+ ::= { tlpAtsConfigVoltageRangeOldEntry 6 }
+
+tlpAtsConfigSource2BrownoutSetOld OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Volts"
+ MAX-ACCESS read-write
+ STATUS obsolete
+ DESCRIPTION
+ "This value dictates the voltage level below which source 2 goes into a
+ brown out condition. The maximum value allowed is dictated by
+ tlpAtsConfigSource2TransferResetOld. The minimum value allowed is dictated by
+ tlpAtsConfigSource2TransferSetOld. If not supported, this value will return
+ ERROR_NO_SUCH_NAME."
+ ::= { tlpAtsConfigVoltageRangeOldEntry 7 }
+
+tlpAtsConfigSource2TransferSetOld OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Volts"
+ MAX-ACCESS read-write
+ STATUS obsolete
+ DESCRIPTION
+ "If input source 2 voltage level falls below this value, a unit connected to
+ source 2 will transition to source 1 (if it is in fair condition as denoted
+ by tlpAtsConfigSource1TransferSetOld). The maximum value allowed is dictated by
+ tlpAtsConfigSource2BrownoutSetOld. The minimum value allowed is dictated by
+ tlpAtsConfigLowVoltageResetOld. If not supported, this value will return
+ ERROR_NO_SUCH_NAME."
+ ::= { tlpAtsConfigVoltageRangeOldEntry 8 }
+
+tlpAtsConfigLowVoltageResetOld OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Volts"
+ MAX-ACCESS read-write
+ STATUS obsolete
+ DESCRIPTION
+ "If a unit is disconnected due to under-voltage or is not powered up yet, the
+ line voltage has to rise above this value before the unit gets connected to
+ the AC input connection. The maximum value allowed is dictated by the lesser
+ value of tlpAtsConfigSource1TransferSetOld and tlpAtsConfigSource2TransferSetOld.
+ The minimum value allowed is dictated by tlpAtsConfigLowVoltageTransferOld. If
+ not supported, this value will return ERROR_NO_SUCH_NAME."
+ ::= { tlpAtsConfigVoltageRangeOldEntry 9 }
+
+tlpAtsConfigLowVoltageTransferOld OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Volts"
+ MAX-ACCESS read-write
+ STATUS obsolete
+ DESCRIPTION
+ "The minimum line voltage allowed before the unit disconnects the
+ AC input connection. The maximum value allowed is dictated by
+ tlpAtsConfigLowVoltageResetOld. The minimum value allowed is dictated by
+ tlpAtsInputBadTransferVoltageLowerBound (inclusively). If not supported, this
+ value will return ERROR_NO_SUCH_NAME."
+ ::= { tlpAtsConfigVoltageRangeOldEntry 10 }
+
+tlpAtsConfigVoltageRangeLimitsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpAtsConfigVoltageRangeLimitsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The voltage range table, as documented by tlpAtsConfigVoltageRangeTable requires
+ that all changes adhere with stack order, from high transfer voltage down to low
+ transfer voltage. In addition to stack order, certain voltage range values have
+ limits defining the absolute minimum and absolute maximum for such values. Any
+ voltage value violating any respective limit defined herein will be rejected."
+ ::= { tlpAtsConfig 3 }
+
+tlpAtsConfigVoltageRangeLimitsEntry OBJECT-TYPE
+ SYNTAX TlpAtsConfigVoltageRangeLimitsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing voltage range limits configuration options for a particular ats."
+ INDEX { tlpDeviceIndex }
+ ::= { tlpAtsConfigVoltageRangeLimitsTable 1 }
+
+TlpAtsConfigVoltageRangeLimitsEntry ::= SEQUENCE {
+ tlpAtsConfigSourceBrownoutSetMinimum Unsigned32,
+ tlpAtsConfigSourceBrownoutSetMaximum Unsigned32,
+ tlpAtsConfigSourceTransferSetMinimum Unsigned32,
+ tlpAtsConfigSourceTransferSetMaximum Unsigned32 }
+
+tlpAtsConfigSourceBrownoutSetMinimum OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Volts"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This value dictates the absolute lower limit by which tlpAtsConfigSource1BrownoutSet
+ and tlpAtsConfigSource2BrownoutSet can be set. tlpAtsConfigSource1TransferSet and
+ tlpAtsConfigSource2TransferSet, respectively, are also used when determining the
+ lowest value a brownout value can be set at any given time. If not supported, this
+ value will return ERROR_NO_SUCH_NAME."
+ ::= { tlpAtsConfigVoltageRangeLimitsEntry 1 }
+
+tlpAtsConfigSourceBrownoutSetMaximum OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Volts"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This value dictates the absolute upper limit by which tlpAtsConfigSource1BrownoutSet
+ and tlpAtsConfigSource2BrownoutSet can be set. tlpAtsConfigSource1TransferReset and
+ tlpAtsConfigSource2TransferReset, respectively, are also used when determining the
+ greatest value a brownout value can be set at any given time. If not supported, this
+ value will return ERROR_NO_SUCH_NAME."
+ ::= { tlpAtsConfigVoltageRangeLimitsEntry 2 }
+
+tlpAtsConfigSourceTransferSetMinimum OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Volts"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This value dictates the absolute lower limit by which tlpAtsConfigSource1TransferSet
+ and tlpAtsConfigSource2TransferSet can be set. tlpAtsConfigLowVoltageReset is also
+ used when determining the lowest value a transferset value can be set at any given
+ time. If not supported, this value will return ERROR_NO_SUCH_NAME."
+ ::= { tlpAtsConfigVoltageRangeLimitsEntry 3 }
+
+tlpAtsConfigSourceTransferSetMaximum OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Volts"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This value dictates the absolute upper limit by which tlpAtsConfigSource1TransferSet
+ and tlpAtsConfigSource2TransferSet can be set. tlpAtsConfigSource1BrownoutSet and
+ tlpAtsConfigSource2BrownoutSet, respectively, are also used when determining the
+ greatest value a transferset value can be set at any given time. If not supported,
+ this value will return ERROR_NO_SUCH_NAME."
+ ::= { tlpAtsConfigVoltageRangeLimitsEntry 4 }
+
+tlpAtsConfigThresholdTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpAtsConfigThresholdEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The configurable threshold options of each ats in device table. This
+ is a sparse dependent table, and will contain some subset of devices that
+ are atss. Not all options are available on all atss."
+ ::= { tlpAtsConfig 4 }
+
+tlpAtsConfigThresholdEntry OBJECT-TYPE
+ SYNTAX TlpAtsConfigThresholdEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing configurable threshold options for a particular ats."
+ INDEX { tlpDeviceIndex }
+ ::= { tlpAtsConfigThresholdTable 1 }
+
+TlpAtsConfigThresholdEntry ::= SEQUENCE {
+ tlpAtsConfigOutputCurrentThreshold Unsigned32,
+ tlpAtsConfigOverTemperatureThreshold Unsigned32,
+ tlpAtsConfigOverVoltageThreshold Unsigned32,
+ tlpAtsConfigOverLoadThreshold Unsigned32 }
+
+tlpAtsConfigOutputCurrentThreshold OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Amps"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The output current measurement at which an over current condition is reported.
+ This value may not be supported on all models. If not supported, this value
+ will return ERROR_NO_SUCH_NAME."
+ ::= { tlpAtsConfigThresholdEntry 1 }
+
+tlpAtsConfigOverTemperatureThreshold OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Celsius"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The system temperature at which an over temperature condition is reported.
+ This value may not be supported on all models. If not supported, this value
+ will return ERROR_NO_SUCH_NAME."
+ ::= { tlpAtsConfigThresholdEntry 2 }
+
+tlpAtsConfigOverVoltageThreshold OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Volts"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The input voltage measurement at which an over voltage condition is reported.
+ This value may not be supported on all models. If not supported, this value
+ will return ERROR_NO_SUCH_NAME."
+ ::= { tlpAtsConfigThresholdEntry 3 }
+
+tlpAtsConfigOverLoadThreshold OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The system load at which an overload condition is reported. This value may not
+ be supported on all models. If not supported, this value will return
+ ERROR_NO_SUCH_NAME."
+ ::= { tlpAtsConfigThresholdEntry 4 }
+
+tlpAtsConfigVoltageRangeTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpAtsConfigVoltageRangeEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The voltage range options in this table is intended to configure the
+ operating voltages of an ats. This is a sparse dependent table, and will
+ contain some subset of devices that are atss. All voltage points defined
+ in this table are listed in a specific order from high to low. All voltage
+ points must satisfy the conditions and ranges defined for each point. Any
+ point violating any of the relative limits will be rejected.
+
+ For optimal operation, it is recommended that tlpAtsConfigHighVoltageReset
+ be set lower than tlpAtsConfigHighVoltageTransfer by a margin no less than 1%
+ of tlpAtsConfigHighVoltageTransfer; and that tlpAtsConfigSource1TransferReset
+ (tlpAtsConfigSource2TransferReset) be set higher than
+ tlpAtsConfigSource1BrownoutSet (tlpAtsConfigSource2BrownoutSet) by a margin no
+ less than 1% of tlpAtsConfigSource1BrownoutSet (tlpAtsConfigSource2BrownoutSet).
+
+ *The upper limit of line voltage is tlpAtsInputHighTransferVoltageUpperBound.
+ The lower limit of line voltage is tlpAtsInputBadTransferVoltageLowerBound. All
+ minimum and maximum limits for each voltage point are all exclusive unless
+ indicated otherwise."
+ ::= { tlpAtsConfig 5 }
+
+tlpAtsConfigVoltageRangeEntry OBJECT-TYPE
+ SYNTAX TlpAtsConfigVoltageRangeEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing voltage range configuration options for a particular ats."
+ INDEX { tlpDeviceIndex, tlpAtsInputLineIndex }
+ ::= { tlpAtsConfigVoltageRangeTable 1 }
+
+TlpAtsConfigVoltageRangeEntry ::= SEQUENCE {
+ tlpAtsConfigHighVoltageTransfer Unsigned32,
+ tlpAtsConfigHighVoltageReset Unsigned32,
+ tlpAtsConfigTransferReset Unsigned32,
+ tlpAtsConfigBrownoutSet Unsigned32,
+ tlpAtsConfigTransferSet Unsigned32,
+ tlpAtsConfigLowVoltageReset Unsigned32,
+ tlpAtsConfigLowVoltageTransfer Unsigned32 }
+
+tlpAtsConfigHighVoltageTransfer OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Volts"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The maximum line voltage allowed on the input source before the unit
+ disconnects the AC input connection. tlpAtsConfigHighVoltageTransfer is the
+ same value for both input sources on some units. On such units, changing
+ this value on one source will change the value on the other source. The
+ maximum value allowed is dictated by tlpAtsInputHighTransferVoltageUpperBound
+ (inclusively). The minimum value allowed is dictated by tlpAtsConfigHighVoltageReset.
+ This value may not be configurable on all models. If not supported, this value will
+ return ERROR_NO_SUCH_NAME."
+ ::= { tlpAtsConfigVoltageRangeEntry 1 }
+
+tlpAtsConfigHighVoltageReset OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Volts"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "If an input connection is disconnected due to over-voltage, the line voltage
+ on the input source has to fall below this value before the unit re-connects
+ the AC input connection for the input source. tlpAtsConfigHighVoltageReset is the
+ same value for both input sources on some units. On such units, changing this
+ value on one source will change the value on the other source. The maximum value
+ allowed is dictated by tlpAtsConfigHighVoltageTransfer. On units where this is
+ the same value for both sources, the minimum value allowed is dictated by the
+ greater of tlpAtsConfigTransferReset.1 and tlpAtsConfigTransferReset.2. On units
+ where the value is distinct for each source, the minimum value allowed is
+ dictated solely by this source's tlpAtsConfigTransferReset. If not supported,
+ this value will return ERROR_NO_SUCH_NAME."
+ ::= { tlpAtsConfigVoltageRangeEntry 2 }
+
+tlpAtsConfigTransferReset OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Volts"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "If input source voltage level is above this value, a unit connected to
+ this other input source will transition to this input source (if it is the
+ preferred source). The maximum value allowed is dictated by
+ tlpAtsConfigHighVoltageReset. The minimum value allowed is dictated by
+ tlpAtsConfigBrownoutSet. If not supported, this value will return
+ ERROR_NO_SUCH_NAME."
+ ::= { tlpAtsConfigVoltageRangeEntry 3 }
+
+tlpAtsConfigBrownoutSet OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Volts"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This value dictates the voltage level below which the input source goes
+ into a brown out condition. The maximum value allowed is dictated by
+ tlpAtsConfigTransferReset. The minimum value allowed is dictated by
+ tlpAtsConfigTransferSet. If not supported, this value will return
+ ERROR_NO_SUCH_NAME."
+ ::= { tlpAtsConfigVoltageRangeEntry 4 }
+
+tlpAtsConfigTransferSet OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Volts"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "If input source voltage level falls below this value, a unit connected to
+ this input source will transition to other input source (if it is in fair
+ condition as denoted by tlpAtsConfigTransferSet). The maximum value allowed
+ is dictated by tlpAtsConfigBrownoutSet. The minimum value allowed is dictated
+ by tlpAtsConfigLowVoltageReset. If not supported, this value will return
+ ERROR_NO_SUCH_NAME."
+ ::= { tlpAtsConfigVoltageRangeEntry 5 }
+
+tlpAtsConfigLowVoltageReset OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Volts"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "If a unit is disconnected due to under-voltage or is not powered up yet, the
+ line voltage has to rise above this value before the unit gets connected to
+ the AC input connection. tlpAtsConfigLowVoltageReset is the same value for both
+ input sources. As such, changing this value on one source will change the value
+ on the other source. The maximum value allowed is dictated by the lesser value
+ of tlpAtsConfigTransferSet.1 and tlpAtsConfigTransferSet.2. The minimum value
+ allowed is dictated by tlpAtsConfigLowVoltageTransfer. If not supported, this
+ value will return ERROR_NO_SUCH_NAME."
+ ::= { tlpAtsConfigVoltageRangeEntry 6 }
+
+tlpAtsConfigLowVoltageTransfer OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Volts"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The minimum line voltage allowed before the unit disconnects the AC input
+ connection. tlpAtsConfigLowVoltageTransfer is the same value for both input
+ sources. As such, changing this value on one source will change the value on the
+ other source. The maximum value allowed is dictated by tlpAtsConfigLowVoltageReset.
+ The minimum value allowed is dictated by tlpAtsInputBadTransferVoltageLowerBound
+ (inclusively). If not supported, this value will return ERROR_NO_SUCH_NAME."
+ ::= { tlpAtsConfigVoltageRangeEntry 7 }
+
+tlpAtsConfigPhaseThresholdTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpAtsConfigPhaseThresholdEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The configuration options of each Ats in device table. This
+ is a sparse dependent table, and will contain some subset of
+ devices that are Atss. Not all options are available on all
+ Atss."
+ ::= { tlpAtsConfig 6 }
+
+tlpAtsConfigPhaseThresholdEntry OBJECT-TYPE
+ SYNTAX TlpAtsConfigPhaseThresholdEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing threshold configuration options for a particular Ats."
+ INDEX { tlpDeviceIndex, tlpAtsPhaseIndex }
+ ::= { tlpAtsConfigPhaseThresholdTable 1 }
+
+TlpAtsConfigPhaseThresholdEntry ::= SEQUENCE {
+ tlpAtsPhaseIndex Unsigned32,
+ tlpAtsConfigOutputCurrentThresholdTolerance Unsigned32,
+ tlpAtsConfigOutputCurrentHighThreshold Unsigned32,
+ tlpAtsConfigOutputCurrentLowThreshold Unsigned32}
+
+tlpAtsPhaseIndex OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The table row index for the Ats phase."
+ ::= { tlpAtsConfigPhaseThresholdEntry 1 }
+
+tlpAtsConfigOutputCurrentThresholdTolerance OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Amps"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The threshold tolerance value used together with output current high/low
+ threshold to evaluate output current high/low condition."
+ ::= { tlpAtsConfigPhaseThresholdEntry 2 }
+
+tlpAtsConfigOutputCurrentHighThreshold OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Amps"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The value at which a output current high condition is declared."
+ ::= { tlpAtsConfigPhaseThresholdEntry 3 }
+
+tlpAtsConfigOutputCurrentLowThreshold OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Amps"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The value at which a output current low condition is declared."
+ ::= { tlpAtsConfigPhaseThresholdEntry 4 }
+
+-- cooling
+
+tlpCoolingIdentNumCooling OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of cooling devices that this agent is currently managing."
+ ::= { tlpCoolingIdent 1 }
+
+tlpCoolingCurrentTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpCoolingCurrentEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The input current for each cooling device in device table. This is a
+ sparse dependent table, and will contain the number of entries based upon the
+ number of cooling device managed by the agent as reported by tlpCoolingIdentNumCooling."
+ ::= { tlpCoolingDetail 3 }
+
+tlpCoolingCurrentEntry OBJECT-TYPE
+ SYNTAX TlpCoolingCurrentEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing input current for a particular cooling device."
+ INDEX { tlpDeviceIndex }
+ ::= { tlpCoolingCurrentTable 1 }
+
+TlpCoolingCurrentEntry ::= SEQUENCE {
+ tlpCoolingUnitCurrent Unsigned32,
+ tlpCoolingCompressorCurrent Unsigned32,
+ tlpCoolingEvaporatorFanCurrent Unsigned32,
+ tlpCoolingCondenserFanCurrent Unsigned32 }
+
+tlpCoolingUnitCurrent OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Amps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total current draw of the unit in tenths of Amps. If not supported,
+ this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingCurrentEntry 1 }
+
+tlpCoolingCompressorCurrent OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Amps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The compressor current draw of the unit in tenths of Amps. If not supported,
+ this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingCurrentEntry 2 }
+
+tlpCoolingEvaporatorFanCurrent OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Amps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current draw of the evaporator fan in tenths of Amps. If not supported,
+ this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingCurrentEntry 3 }
+
+tlpCoolingCondenserFanCurrent OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Amps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current draw of the condenser fan in tenths of Amps. If not supported,
+ this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingCurrentEntry 4 }
+
+tlpCoolingTemperatureFahrenheitTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpCoolingTemperatureFahrenheitEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The temperature details for each cooling device in device table. This is a
+ sparse dependent table, and will contain the number of entries based upon the
+ number of cooling device managed by the agent as reported by tlpCoolingIdentNumCooling."
+ ::= { tlpCoolingTemperature 1 }
+
+tlpCoolingTemperatureFahrenheitEntry OBJECT-TYPE
+ SYNTAX TlpCoolingTemperatureFahrenheitEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing temperature details for a particular cooling device."
+ INDEX { tlpDeviceIndex }
+ ::= { tlpCoolingTemperatureFahrenheitTable 1 }
+
+TlpCoolingTemperatureFahrenheitEntry ::= SEQUENCE {
+ tlpCoolingAmbientDegF Integer32,
+ tlpCoolingSupplyAirDegF Integer32,
+ tlpCoolingReturnAirDegF Integer32,
+ tlpCoolingCondenserInletDegF Integer32,
+ tlpCoolingEvaporatorDegF Integer32,
+ tlpCoolingSuctionDegF Integer32,
+ tlpCoolingRemoteDegF Integer32,
+ tlpCoolingCondenserOutletDegF Integer32}
+
+tlpCoolingAmbientDegF OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 degrees Fahrenheit"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The ambient temperature in tenths degrees Fahrenheit. If not supported,
+ this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingTemperatureFahrenheitEntry 1 }
+
+tlpCoolingSupplyAirDegF OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 degrees Fahrenheit"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The temperature of the air entering the cooling unit in tenths degrees Fahrenheit.
+ If not supported, this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingTemperatureFahrenheitEntry 2 }
+
+tlpCoolingReturnAirDegF OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 degrees Fahrenheit"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The temperature of the air entering the cooling unit in tenths degrees Fahrenheit.
+ If not supported, this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingTemperatureFahrenheitEntry 3 }
+
+tlpCoolingCondenserInletDegF OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 degrees Fahrenheit"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The temperature of the air entering the condenser in tenths degrees Fahrenheit.
+ If not supported, this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingTemperatureFahrenheitEntry 4 }
+
+tlpCoolingEvaporatorDegF OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 degrees Fahrenheit"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The temperature of the evaporator surface in tenths degrees Fahrenheit.
+ If not supported, this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingTemperatureFahrenheitEntry 5 }
+
+tlpCoolingSuctionDegF OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 degrees Fahrenheit"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The temperature of the low pressure refrigerant line in tenths degrees Fahrenheit.
+ If not supported, this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingTemperatureFahrenheitEntry 6 }
+
+tlpCoolingRemoteDegF OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 degrees Fahrenheit"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The external remote temperature in tenths degrees Fahrenheit. If not supported,
+ this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingTemperatureFahrenheitEntry 7 }
+
+tlpCoolingCondenserOutletDegF OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 degrees Fahrenheit"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The temperature of the air leaving the condenser in tenths degrees Fahrenheit.
+ If not supported, this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingTemperatureFahrenheitEntry 8 }
+
+tlpCoolingTemperatureCelsiusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpCoolingTemperatureCelsiusEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The temperature details for each cooling device in device table. This is a
+ sparse dependent table, and will contain the number of entries based upon the
+ number of cooling device managed by the agent as reported by tlpCoolingIdentNumCooling."
+ ::= { tlpCoolingTemperature 2 }
+
+tlpCoolingTemperatureCelsiusEntry OBJECT-TYPE
+ SYNTAX TlpCoolingTemperatureCelsiusEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing temperature details for a particular cooling device."
+ INDEX { tlpDeviceIndex }
+ ::= { tlpCoolingTemperatureCelsiusTable 1 }
+
+TlpCoolingTemperatureCelsiusEntry ::= SEQUENCE {
+ tlpCoolingAmbientDegC Integer32,
+ tlpCoolingSupplyAirDegC Integer32,
+ tlpCoolingReturnAirDegC Integer32,
+ tlpCoolingCondenserInletDegC Integer32,
+ tlpCoolingEvaporatorDegC Integer32,
+ tlpCoolingSuctionDegC Integer32,
+ tlpCoolingRemoteDegC Integer32,
+ tlpCoolingCondenserOutletDegC Integer32 }
+
+tlpCoolingAmbientDegC OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 degrees Celsius"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The ambient temperature in tenths degrees Celsius. If not supported,
+ this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingTemperatureCelsiusEntry 1 }
+
+tlpCoolingSupplyAirDegC OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 degrees Celsius"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The temperature of the air entering the cooling unit in tenths degrees Celsius. If not supported,
+ this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingTemperatureCelsiusEntry 2 }
+
+tlpCoolingReturnAirDegC OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 degrees Celsius"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The temperature of the air entering the cooling unit in tenths degrees Celsius. If not supported,
+ this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingTemperatureCelsiusEntry 3 }
+
+tlpCoolingCondenserInletDegC OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 degrees Celsius"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The temperature of the air entering the condenser in tenths degrees Celsius. If not supported,
+ this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingTemperatureCelsiusEntry 4 }
+
+tlpCoolingEvaporatorDegC OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 degrees Celsius"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The temperature of the evaporator surface in tenths degrees Celsius. If not supported,
+ this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingTemperatureCelsiusEntry 5 }
+
+tlpCoolingSuctionDegC OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 degrees Celsius"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The temperature of the low pressure refrigerant line in tenths degrees Celsius. If not supported,
+ this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingTemperatureCelsiusEntry 6 }
+
+tlpCoolingRemoteDegC OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 degrees Celsius"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The external remote temperature in tenths degrees Celsius. If not supported,
+ this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingTemperatureCelsiusEntry 7 }
+
+tlpCoolingCondenserOutletDegC OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 degrees Celsius"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The temperature of the air leaving the condenser in tenths degrees Celsius. If not supported,
+ this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingTemperatureCelsiusEntry 8 }
+
+tlpCoolingPressureMpaTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpCoolingPressureMpaEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The pressure detail for each cooling device in device table. This is a
+ sparse dependent table, and will contain the number of entries based upon the
+ number of cooling device managed by the agent as reported by tlpCoolingIdentNumCooling."
+ ::= { tlpCoolingPressure 1 }
+
+tlpCoolingPressureMpaEntry OBJECT-TYPE
+ SYNTAX TlpCoolingPressureMpaEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing pressure details for a particular cooling device."
+ INDEX { tlpDeviceIndex }
+ ::= { tlpCoolingPressureMpaTable 1 }
+
+TlpCoolingPressureMpaEntry ::= SEQUENCE {
+ tlpCoolingSuctionPressureMpa Unsigned32,
+ tlpCoolingDischargePressureMpa Unsigned32 }
+
+tlpCoolingSuctionPressureMpa OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Mpa"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The pressure of the compressor discharge line in tenths of Mpa. If not supported,
+ this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingPressureMpaEntry 1 }
+
+tlpCoolingDischargePressureMpa OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Mpa"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The pressure of the compressor discharge line in tenths of Mpa. If not supported,
+ this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingPressureMpaEntry 2 }
+
+tlpCoolingPressurePsiTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpCoolingPressurePsiEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The pressure detail for each cooling device in device table. This is a
+ sparse dependent table, and will contain the number of entries based upon the
+ number of cooling device managed by the agent as reported by tlpCoolingIdentNumCooling."
+ ::= { tlpCoolingPressure 2 }
+
+tlpCoolingPressurePsiEntry OBJECT-TYPE
+ SYNTAX TlpCoolingPressurePsiEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing pressure details for a particular cooling device."
+ INDEX { tlpDeviceIndex }
+ ::= { tlpCoolingPressurePsiTable 1 }
+
+TlpCoolingPressurePsiEntry ::= SEQUENCE {
+ tlpCoolingSuctionPressurePsi Unsigned32,
+ tlpCoolingDischargePressurePsi Unsigned32 }
+
+tlpCoolingSuctionPressurePsi OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Psi"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The pressure of the compressor discharge line in tenths of Psi. If not supported,
+ this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingPressurePsiEntry 1 }
+
+tlpCoolingDischargePressurePsi OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 Psi"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The pressure of the compressor discharge line in tenths of Psi. If not supported,
+ this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingPressurePsiEntry 2 }
+
+tlpCoolingDynamicTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpCoolingDynamicEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The dynamic detail for each cooling device in device table. This is a
+ sparse dependent table, and will contain the number of entries based upon the
+ number of cooling device managed by the agent as reported by tlpCoolingIdentNumCooling."
+ ::= { tlpCoolingDetail 4 }
+
+tlpCoolingDynamicEntry OBJECT-TYPE
+ SYNTAX TlpCoolingDynamicEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry dynamic details for a particular cooling device."
+ INDEX { tlpDeviceIndex }
+ ::= { tlpCoolingDynamicTable 1 }
+
+TlpCoolingDynamicEntry ::= SEQUENCE {
+ tlpCoolingEvaporatorFanSpeed INTEGER,
+ tlpCoolingCondenserFanSpeed INTEGER,
+ tlpCoolingCompressorFrequency Unsigned32,
+ tlpCoolingEEVSteps INTEGER }
+
+tlpCoolingEvaporatorFanSpeed OBJECT-TYPE
+ SYNTAX INTEGER {
+ off(0),
+ low(1),
+ mediumLow(2),
+ medium(3),
+ mediumHigh(4),
+ high(5),
+ auto(6) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current speed of the evaporator fan. If not supported,
+ this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingDynamicEntry 1 }
+
+tlpCoolingCondenserFanSpeed OBJECT-TYPE
+ SYNTAX INTEGER {
+ off(0),
+ low(1),
+ mediumLow(2),
+ medium(3),
+ mediumHigh(4),
+ high(5),
+ auto(6) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current speed of the condenser fan. If not supported,
+ this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingDynamicEntry 2 }
+
+tlpCoolingCompressorFrequency OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "Hertz"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The operating mechanical frequency(Hz) of the compressor. If not supported,
+ this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingDynamicEntry 3 }
+
+tlpCoolingEEVSteps OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current EEV steps. If not supported,
+ this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingDynamicEntry 4 }
+
+tlpCoolingRuntimeTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpCoolingRuntimeEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The runtime detail for each cooling device in device table. This is a
+ sparse dependent table, and will contain the number of entries based upon the
+ number of cooling device managed by the agent as reported by tlpCoolingIdentNumCooling."
+ ::= { tlpCoolingDetail 5 }
+
+tlpCoolingRuntimeEntry OBJECT-TYPE
+ SYNTAX TlpCoolingRuntimeEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing runtime for a particular cooling device."
+ INDEX { tlpDeviceIndex }
+ ::= { tlpCoolingRuntimeTable 1 }
+
+TlpCoolingRuntimeEntry ::= SEQUENCE {
+ tlpCoolingCompressorRunDays Unsigned32,
+ tlpCoolingCondensatePumpRunDays Unsigned32,
+ tlpCoolingAirFilterRunHours Unsigned32,
+ tlpCoolingEvaporatorFanRunDays Unsigned32,
+ tlpCoolingCondenserFanRunDays Unsigned32,
+ tlpCoolingAtomizerRunDays Unsigned32 }
+
+tlpCoolingCompressorRunDays OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "days"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total days the compressor has been under operation. If not supported,
+ this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingRuntimeEntry 1 }
+
+tlpCoolingCondensatePumpRunDays OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "days"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total days the condensate pump has been under operation. If not supported,
+ this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingRuntimeEntry 2}
+
+tlpCoolingAirFilterRunHours OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "hours"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total hours the air filter has been under operation. If not supported,
+ this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingRuntimeEntry 3 }
+
+tlpCoolingEvaporatorFanRunDays OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "days"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total days the evaporator fan has been under operation. If not supported,
+ this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingRuntimeEntry 4 }
+
+tlpCoolingCondenserFanRunDays OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "days"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total days the condenser fan has been under operation. If not supported,
+ this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingRuntimeEntry 5 }
+
+tlpCoolingAtomizerRunDays OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "days"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total days the atomizer has been under operation. If not supported,
+ this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingRuntimeEntry 6 }
+
+tlpCoolingStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpCoolingStatusEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The status detail for each cooling device in device table. This is a
+ sparse dependent table, and will contain the number of entries based upon the
+ number of cooling device managed by the agent as reported by tlpCoolingIdentNumCooling."
+ ::= { tlpCoolingDetail 6 }
+
+tlpCoolingStatusEntry OBJECT-TYPE
+ SYNTAX TlpCoolingStatusEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing status for a particular cooling device."
+ INDEX { tlpDeviceIndex }
+ ::= { tlpCoolingStatusTable 1 }
+
+TlpCoolingStatusEntry ::= SEQUENCE {
+ tlpCoolingOperatingMode INTEGER,
+ tlpCoolingCoolOutput Unsigned32,
+ tlpCoolingAlarmStatus INTEGER,
+ tlpCoolingCompressorStatus INTEGER,
+ tlpCoolingWaterStatus INTEGER}
+
+tlpCoolingOperatingMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ off(0),
+ idle(1),
+ cooling(2),
+ shuttingDown(3),
+ dehumidifying(4),
+ defrosting(5),
+ notConnected(6) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current operating mode. If not supported,
+ this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingStatusEntry 1 }
+
+tlpCoolingCoolOutput OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "0.1 kilowatts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current cooling output of the cooling device in tenth of kilowatt. If not supported,
+ this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingStatusEntry 2 }
+
+tlpCoolingAlarmStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ noAlarm(0),
+ warning(1),
+ critical(2)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current alarm status of the cooling device. If not supported,
+ this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingStatusEntry 3 }
+
+tlpCoolingCompressorStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ off(0),
+ on(1)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current operating status of compressor. If not supported,
+ this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingStatusEntry 4 }
+
+tlpCoolingWaterStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ notFull(0),
+ full(1)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current water status of cooling unit. If not supported,
+ this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingStatusEntry 5 }
+
+tlpCoolingControlTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpCoolingControlEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The actionable controls for each cooling device in device table. This
+ is a sparse dependent table, and will contain some subset of
+ devices that are cooling device."
+ ::= { tlpCoolingControl 1 }
+
+tlpCoolingControlEntry OBJECT-TYPE
+ SYNTAX TlpCoolingControlEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing controls for a particular cooling device."
+ INDEX { tlpDeviceIndex }
+ ::= { tlpCoolingControlTable 1 }
+
+TlpCoolingControlEntry ::= SEQUENCE {
+ tlpCoolingOnOff INTEGER }
+
+tlpCoolingOnOff OBJECT-TYPE
+ SYNTAX INTEGER {
+ turnOffUnit(0),
+ turnOnUnit(1) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Turn the unit on or off."
+ ::= { tlpCoolingControlEntry 1 }
+
+tlpCoolingConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpCoolingConfigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The configuration details for each each cooling device in device table. This
+ is a sparse dependent table, and will contain some subset of
+ devices that are cooling device. Not all options are available on all
+ cooling devices."
+ ::= { tlpCoolingConfig 1 }
+
+tlpCoolingConfigEntry OBJECT-TYPE
+ SYNTAX TlpCoolingConfigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry configuration details for a particular cooling device."
+ INDEX { tlpDeviceIndex }
+ ::= { tlpCoolingConfigTable 1 }
+
+TlpCoolingConfigEntry ::= SEQUENCE {
+ tlpCoolingAutoStart INTEGER,
+ tlpCoolingFanSpeed INTEGER,
+ tlpCoolingControlType INTEGER,
+ tlpCoolingDisplayUnits INTEGER,
+ tlpCoolingBeepOnKey INTEGER,
+ tlpCoolingInputContactType INTEGER,
+ tlpCoolingOutputContactType INTEGER,
+ tlpCoolingOutputRelaySource INTEGER,
+ tlpCoolingOutputRelayDefault INTEGER,
+ tlpCoolingOffOnInputContact INTEGER,
+ tlpCoolingOffOnLeak INTEGER,
+ tlpCoolingWaterLeakContactType INTEGER,
+ tlpCoolingAirFilterInterval Unsigned32,
+ tlpCoolingAirFilterAlarm INTEGER,
+ tlpCoolingMaxAirFilterRunHours Unsigned32,
+ tlpCoolingStartTimer Unsigned32,
+ tlpCoolingStopTimer Unsigned32,
+ tlpCoolingEnergyMode INTEGER,
+ tlpCoolingDefrostMode INTEGER,
+ tlpCoolingRemoteTemperatureSensor INTEGER,
+ tlpCoolingDehumidifyingMode INTEGER,
+ tlpCoolingFanAlwaysOn INTEGER,
+ tlpCoolingQuietMode INTEGER,
+ tlpCoolingHotGasBypass INTEGER,
+ tlpCoolingAutoFanSpeed INTEGER }
+
+tlpCoolingAutoStart OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Specifies if the unit should start automatically on power up.
+ If not supported, this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingConfigEntry 1 }
+
+tlpCoolingFanSpeed OBJECT-TYPE
+ SYNTAX INTEGER {
+ off(0),
+ low(1),
+ mediumLow(2),
+ medium(3),
+ mediumHigh(4),
+ high(5),
+ auto(6) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Specifies the actual speed of the evaporator fan. Setting the fan speed
+ to auto(6) will enable tlpCoolingAutoFanSpeed; however, on most units getting
+ the fan speed will return the actual fan speed regardless whether auto fan
+ speed is enabled or disabled. The value auto(6) is returned only on units that
+ do not report the actual fan speed when auto fan speed is enabled. Not all
+ values are supported on all cooling units. Invalid values will return an appropriate
+ error when accessed. If not supported, this value will always return ERROR_NO_SUCH_NAME"
+ ::= { tlpCoolingConfigEntry 2 }
+
+tlpCoolingControlType OBJECT-TYPE
+ SYNTAX INTEGER {
+ returnAirTemperature(0),
+ remoteTemperature(1) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Specifies which temperature is used as a control point. If not supported,
+ this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingConfigEntry 3 }
+
+tlpCoolingDisplayUnits OBJECT-TYPE
+ SYNTAX INTEGER {
+ metric(0),
+ english(1) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Specifies whether displays output values in Metric or English formats. If not supported,
+ this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingConfigEntry 4 }
+
+tlpCoolingBeepOnKey OBJECT-TYPE
+ SYNTAX INTEGER {
+ noBeep(0),
+ beepOn(1) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Specifies whether a beep is emitted when a key is pressed on the unit's display panel. If not supported,
+ this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingConfigEntry 5 }
+
+tlpCoolingInputContactType OBJECT-TYPE
+ SYNTAX INTEGER {
+ normallyClosed(0),
+ normallyOpen(1) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The input contact type. If not supported, this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingConfigEntry 6 }
+
+tlpCoolingOutputContactType OBJECT-TYPE
+ SYNTAX INTEGER {
+ normallyClosed(0),
+ normallyOpen(1) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The output contact type. If not supported, this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingConfigEntry 7 }
+
+tlpCoolingOutputRelaySource OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ allAlarmsAndWarnings(1),
+ criticalAlarmsOnly(2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The alarm level that causes the output relay to activate. If not supported,
+ this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingConfigEntry 8 }
+
+tlpCoolingOutputRelayDefault OBJECT-TYPE
+ SYNTAX INTEGER {
+ normallyClosed(0),
+ normallyOpen(1) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Type of contact to make when output relay is activated. If not supported,
+ this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingConfigEntry 9 }
+
+tlpCoolingOffOnInputContact OBJECT-TYPE
+ SYNTAX INTEGER {
+ turnOff(0),
+ alarmOnly(1) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Indicates if the unit should stop cooling when input contact is activated. If not supported,
+ this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingConfigEntry 10 }
+
+tlpCoolingOffOnLeak OBJECT-TYPE
+ SYNTAX INTEGER {
+ turnOff(0),
+ alarmOnly(1) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Indicates if the unit should stop cooling when leak input is activated. If not supported,
+ this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingConfigEntry 11 }
+
+tlpCoolingWaterLeakContactType OBJECT-TYPE
+ SYNTAX INTEGER {
+ normallyClosed(0),
+ normallyOpen(1) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The water leak contact type. If not supported,
+ this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingConfigEntry 12 }
+
+tlpCoolingAirFilterInterval OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "weeks"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The number of weeks before the air filter needs to be changed.
+ If not supported, this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingConfigEntry 13 }
+
+tlpCoolingAirFilterAlarm OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1) }
+ UNITS "hours"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "When enabled, an alarm should occur when the maximum number of air filter run hours
+ has been exceeded. If not supported, this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingConfigEntry 14 }
+
+tlpCoolingMaxAirFilterRunHours OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "hours"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The maximum interval for air filter run hours before warning is annunciated.
+ If not supported, this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingConfigEntry 15 }
+
+tlpCoolingStartTimer OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "minutes"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The unit will start operate after the specified timer elapsed. If not supported,
+ this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingConfigEntry 16 }
+
+tlpCoolingStopTimer OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "minutes"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The unit will switch to standby mode after the specified timer elapsed. If not supported,
+ this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingConfigEntry 17 }
+
+tlpCoolingEnergyMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ normalCooling(0),
+ energySaving(1) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This option enables or disables the energy saving mode.
+ If not supported, this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingConfigEntry 18 }
+
+tlpCoolingDefrostMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This option enables or disables the defrost mode.
+ If not supported, this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingConfigEntry 19 }
+
+tlpCoolingRemoteTemperatureSensor OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This option enables or disables the remote temperature sensor.
+ If not supported, this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingConfigEntry 20 }
+
+tlpCoolingDehumidifyingMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This option enables or disables the dehumidifying mode.
+ If not supported, this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingConfigEntry 21 }
+
+tlpCoolingFanAlwaysOn OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This option enables or disables the fan always on.
+ If not supported, this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingConfigEntry 22 }
+
+tlpCoolingQuietMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This option enables or disables the quiet mode.
+ If not supported, this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingConfigEntry 23 }
+
+tlpCoolingHotGasBypass OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This option enables or disables the hot gas bypass.
+ If not supported, this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingConfigEntry 24 }
+
+tlpCoolingAutoFanSpeed OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This option enables or disables the auto fan speed.
+ If not supported, this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingConfigEntry 25 }
+
+
+tlpCoolingConfigTemperatureFahrenheitTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpCoolingConfigTemperatureFahrenheitEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The configuration details for each each cooling device in device table. This
+ is a sparse dependent table, and will contain some subset of
+ devices that are cooling device. Not all options are available on all
+ cooling devices."
+ ::= { tlpCoolingConfig 2 }
+
+tlpCoolingConfigTemperatureFahrenheitEntry OBJECT-TYPE
+ SYNTAX TlpCoolingConfigTemperatureFahrenheitEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry configuration details for a particular cooling device."
+ INDEX { tlpDeviceIndex }
+ ::= { tlpCoolingConfigTemperatureFahrenheitTable 1 }
+
+TlpCoolingConfigTemperatureFahrenheitEntry ::= SEQUENCE {
+ tlpCoolingSetPointDegF Integer32,
+ tlpCoolingSupplyAirHighLimitDegF Integer32,
+ tlpCoolingSupplyAirLowLimitDegF Integer32,
+ tlpCoolingMaxDeviationLimitDegF Integer32,
+ tlpCoolingReturnAirHighLimitDegF Integer32,
+ tlpCoolingReturnAirLowLimitDegF Integer32,
+ tlpCoolingRemoteSetPointDegF Integer32 }
+
+tlpCoolingSetPointDegF OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 degrees Fahrenheit"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The set point temperature the unit will control the temperature in tenths degrees Fahrenheit.
+ If not supported, this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingConfigTemperatureFahrenheitEntry 1 }
+
+tlpCoolingSupplyAirHighLimitDegF OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 degrees Fahrenheit"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Maximum allowed supply air temperature in tenths degrees Fahrenheit before firing an alarm.
+ If not supported, this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingConfigTemperatureFahrenheitEntry 2 }
+
+tlpCoolingSupplyAirLowLimitDegF OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 degrees Fahrenheit"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Minimum allowed supply air temperature in tenths degrees Fahrenheit before firing an alarm.
+ If not supported, this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingConfigTemperatureFahrenheitEntry 3 }
+
+tlpCoolingMaxDeviationLimitDegF OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 degrees Fahrenheit"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Maximum allowed air temperature deviation from set temperature before firing an alarm.
+ If not supported, this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingConfigTemperatureFahrenheitEntry 4 }
+
+tlpCoolingReturnAirHighLimitDegF OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 degrees Fahrenheit"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Maximum allowed supply air temperature in tenths degrees Fahrenheit before firing an alarm.
+ If not supported, this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingConfigTemperatureFahrenheitEntry 5 }
+
+tlpCoolingReturnAirLowLimitDegF OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 degrees Fahrenheit"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Minimum allowed supply air temperature in tenths degrees Fahrenheit before firing an alarm.
+ If not supported, this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingConfigTemperatureFahrenheitEntry 6 }
+
+tlpCoolingRemoteSetPointDegF OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 degrees Fahrenheit"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The remote set point temperature the unit will control the temperature in tenths degrees Fahrenheit.
+ If not supported, this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingConfigTemperatureFahrenheitEntry 7 }
+
+
+tlpCoolingConfigTemperatureCelsiusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpCoolingConfigTemperatureCelsiusEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The configuration details for each cooling device in device table. This
+ is a sparse dependent table, and will contain some subset of
+ devices that are cooling device. Not all options are available on all
+ cooling devices."
+ ::= { tlpCoolingConfig 3 }
+
+tlpCoolingConfigTemperatureCelsiusEntry OBJECT-TYPE
+ SYNTAX TlpCoolingConfigTemperatureCelsiusEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry configuration details for a particular cooling device."
+ INDEX { tlpDeviceIndex }
+ ::= { tlpCoolingConfigTemperatureCelsiusTable 1 }
+
+TlpCoolingConfigTemperatureCelsiusEntry ::= SEQUENCE {
+ tlpCoolingSetPointDegC Integer32,
+ tlpCoolingSupplyAirHighLimitDegC Integer32,
+ tlpCoolingSupplyAirLowLimitDegC Integer32,
+ tlpCoolingMaxDeviationLimitDegC Integer32,
+ tlpCoolingReturnAirHighLimitDegC Integer32,
+ tlpCoolingReturnAirLowLimitDegC Integer32,
+ tlpCoolingRemoteSetPointDegC Integer32 }
+
+tlpCoolingSetPointDegC OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 degrees Celsius"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The set point temperature the unit will control the temperature in tenths degrees Celsius.
+ If not supported, this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingConfigTemperatureCelsiusEntry 1 }
+
+tlpCoolingSupplyAirHighLimitDegC OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 degrees Celsius"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Maximum allowed supply air temperature in tenths degrees Celsius before firing an alarm.
+ If not supported, this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingConfigTemperatureCelsiusEntry 2 }
+
+tlpCoolingSupplyAirLowLimitDegC OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 degrees Celsius"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Minimum allowed supply air temperature in tenths degrees Celsius before firing an alarm.
+ If not supported, this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingConfigTemperatureCelsiusEntry 3 }
+
+tlpCoolingMaxDeviationLimitDegC OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 degrees Celsius"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Maximum allowed air temperature deviation from set temperature before firing an alarm.
+ If not supported, this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingConfigTemperatureCelsiusEntry 4 }
+
+tlpCoolingReturnAirHighLimitDegC OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 degrees Celsius"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Maximum allowed return air temperature in tenths degrees Celsius before firing an alarm.
+ If not supported, this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingConfigTemperatureCelsiusEntry 5 }
+
+tlpCoolingReturnAirLowLimitDegC OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 degrees Celsius"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Minimum allowed return air temperature in tenths degrees Celsius before firing an alarm.
+ If not supported, this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingConfigTemperatureCelsiusEntry 6 }
+
+tlpCoolingRemoteSetPointDegC OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "0.1 degrees Celsius"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The remote set point temperature the unit will control the temperature in tenths degrees Celsius.
+ If not supported, this value will always return ERROR_NO_SUCH_NAME."
+ ::= { tlpCoolingConfigTemperatureCelsiusEntry 7 }
+
+-- kvm
+
+tlpKvmIdentNumKvm OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of kvm devices that this agent is currently managing."
+ ::= { tlpKvmIdent 1 }
+
+-- rackTrack
+
+tlpRackTrackIdentNumRackTrack OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of rack track devices that this agent is currently managing."
+ ::= { tlpRackTrackIdent 1 }
+
+-- switch
+
+tlpSwitchIdentNumSwitch OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of switch devices that this agent is currently managing."
+ ::= { tlpSwitchIdent 1 }
+
+-- software
+
+tlpAgentType OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(0),
+ pal(1),
+ pansa(2),
+ delta(3),
+ sinetica(4),
+ netos6(5),
+ netos7(6),
+ panms(7),
+ nmc5(8) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The type of PowerAlert engine providing this data."
+ ::= { tlpAgentIdent 1 }
+
+tlpAgentVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The version of the agent software."
+ ::= { tlpAgentIdent 2 }
+
+tlpAgentDriverVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The driver version of the agent software."
+ ::= { tlpAgentIdent 3 }
+
+tlpAgentMAC OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The MAC Address of the agent."
+ ::= { tlpAgentIdent 4 }
+
+tlpAgentSerialNum OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Serial number of the web card providing the agent data. This value is
+ only supported by a web card agent. PowerAlert for PC (PAL) agents do
+ not support this value and will return ERROR_NO_SUCH_NAME."
+ ::= { tlpAgentIdent 5 }
+
+tlpAgentUuid OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Universally unique identifier for this host in the form 8-4-4-4-12 for a
+ total of 36 characters (32 alphanumeric characters and four hyphens). For
+ example: 550e8400-e29b-41d4-a716-446655440000."
+ ::= { tlpAgentIdent 6 }
+
+tlpAgentAttributesSupports OBJECT IDENTIFIER
+ ::= { tlpAgentAttributes 1 }
+
+tlpAgentAttributesSupportsHTTP OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates whether the agent supports HTTP connections."
+ ::= { tlpAgentAttributesSupports 1 }
+
+tlpAgentAttributesSupportsHTTPS OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates whether the agent supports HTTPS connections."
+ ::= { tlpAgentAttributesSupports 2 }
+
+tlpAgentAttributesSupportsFTP OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates whether the agent supports FTP connections."
+ ::= { tlpAgentAttributesSupports 3 }
+
+tlpAgentAttributesSupportsTelnetMenu OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates whether the agent supports Telnet menu connections."
+ ::= { tlpAgentAttributesSupports 4 }
+
+tlpAgentAttributesSupportsTelnetCLI OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates whether the agent supports Telnet CLI connections."
+ ::= { tlpAgentAttributesSupports 5 }
+
+tlpAgentAttributesSupportsSSHMenu OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates whether the agent supports SSH menu connections."
+ ::= { tlpAgentAttributesSupports 6 }
+
+tlpAgentAttributesSupportsSSHCLI OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates whether the agent supports SSH CLI connections."
+ ::= { tlpAgentAttributesSupports 7 }
+
+tlpAgentAttributesSupportsSNMP OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates whether the agent supports SNMP connections."
+ ::= { tlpAgentAttributesSupports 8 }
+
+tlpAgentAttributesSupportsSNMPTrap OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates whether the agent supports listening for SNMP traps. This
+ is only applicable for network monitoring applications, PowerAlert
+ Shutdown Agent for an example, that connect to a web card or PowerAlert
+ Local and listen for outbound traps. As such, this value is not supported
+ and will always return 2(false) for a web card or PowerAlert Local."
+ ::= { tlpAgentAttributesSupports 9 }
+
+tlpAgentAttributesAutostart OBJECT IDENTIFIER
+ ::= { tlpAgentAttributes 2 }
+
+tlpAgentAttributesAutostartHTTP OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates whether the agent autostarts HTTP services."
+ ::= { tlpAgentAttributesAutostart 1 }
+
+tlpAgentAttributesAutostartHTTPS OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates whether the agent autostarts HTTPS services."
+ ::= { tlpAgentAttributesAutostart 2 }
+
+tlpAgentAttributesAutostartFTP OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates whether the agent autostarts FTP services."
+ ::= { tlpAgentAttributesAutostart 3 }
+
+tlpAgentAttributesAutostartTelnetMenu OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates whether the agent autostarts Telnet menu services."
+ ::= { tlpAgentAttributesAutostart 4 }
+
+tlpAgentAttributesAutostartTelnetCLI OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates whether the agent autostarts Telnet CLI services."
+ ::= { tlpAgentAttributesAutostart 5 }
+
+tlpAgentAttributesAutostartSSHMenu OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates whether the agent autostarts SSH menu services."
+ ::= { tlpAgentAttributesAutostart 6 }
+
+tlpAgentAttributesAutostartSSHCLI OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates whether the agent autostarts SSH CLI services."
+ ::= { tlpAgentAttributesAutostart 7 }
+
+tlpAgentAttributesAutostartSNMP OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates whether the agent autostarts SNMP services."
+ ::= { tlpAgentAttributesAutostart 8 }
+
+tlpAgentAttributesSnmp OBJECT IDENTIFIER
+ ::= { tlpAgentAttributes 3 }
+
+tlpAgentAttributesSNMPv1Enabled OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates whether the agent will allow SNMPv1 connections."
+ ::= { tlpAgentAttributesSnmp 1 }
+
+tlpAgentAttributesSNMPv2cEnabled OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates whether the agent will allow SNMPv2c connections."
+ ::= { tlpAgentAttributesSnmp 2 }
+
+tlpAgentAttributesSNMPv3Enabled OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates whether the agent will allow SNMPv3 connections."
+ ::= { tlpAgentAttributesSnmp 3 }
+
+tlpAgentAttributesPorts OBJECT IDENTIFIER
+ ::= { tlpAgentAttributes 4 }
+
+tlpAgentAttributesHTTPPort OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The port used for HTTP communications."
+ ::= { tlpAgentAttributesPorts 1 }
+
+tlpAgentAttributesHTTPSPort OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The port used for HTTPS communications."
+ ::= { tlpAgentAttributesPorts 2 }
+
+tlpAgentAttributesFTPPort OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The port used for FTP communications."
+ ::= { tlpAgentAttributesPorts 3 }
+
+tlpAgentAttributesTelnetMenuPort OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The port used for Telnet Menu communications."
+ ::= { tlpAgentAttributesPorts 4 }
+
+tlpAgentAttributesTelnetCLIPort OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The port used for Telnet CLI communications."
+ ::= { tlpAgentAttributesPorts 5 }
+
+tlpAgentAttributesSSHMenuPort OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The port used for SSH Menu communications."
+ ::= { tlpAgentAttributesPorts 6 }
+
+tlpAgentAttributesSSHCLIPort OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The port used for SSH CLI communications."
+ ::= { tlpAgentAttributesPorts 7 }
+
+tlpAgentAttributesSNMPPort OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The port used for SNMP communications."
+ ::= { tlpAgentAttributesPorts 8 }
+
+tlpAgentAttributesSNMPTrapPort OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The port used for SNMP trap and notifications."
+ ::= { tlpAgentAttributesPorts 9 }
+
+tlpAgentConfigRemoteRegistration OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Registers an SNMP contact's IP address and the port on which
+ the contact is listening for SNMP traps. Setting this
+ value is used to CREATE a table entry in a non-standard way.
+ Getting this value will return a string INADDR_ANY and any
+ port number.
+
+ The port number should always be included. When unregistering
+ an SNMP contact, the requester's IP address should be provided
+ with a port number of 0. When setting or unsetting this OID,
+ the IP address string should never be 0 nor should it be empty.
+
+ The registration uses its default community string to register
+ each contact. To use a community other than the default, then
+ it must be appended to the end of the string delimited with a
+ comma.
+
+ The address should be of the format 0.0.0.0:00000 for IPv4.
+ If IPv6 is supported, use the bracket-enclosed format given
+ in IETF RFC 2732 Section 2, with the following examples:
+
+ [FEDC:BA98:7654:3210:FEDC:BA98:7654:3210]:80
+ [1080:0:0:0:8:800:200C:417A]:162
+ [3ffe:2a00:100:7031::1]:162
+ [1080::8:800:200C:417A]:162,myCommunity
+ [::192.9.5.5]:162,myCommunity
+ [::FFFF:129.144.52.38]:80
+ [2010:836B:4179::836B:4179]:162"
+ ::= { tlpAgentConfig 1 }
+
+tlpAgentConfigCurrentTime OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The current date and time of the system."
+ ::= { tlpAgentConfig 2 }
+
+tlpAgentNumEmailContacts OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of email contacts currently defined in the agent."
+ ::= { tlpAgentEmailContacts 1 }
+
+tlpAgentEmailContactTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpAgentEmailContactEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of email contact entries. The number of entries is given by
+ the value of tlpAgentNumEmailContacts."
+ ::= { tlpAgentEmailContacts 2 }
+
+tlpAgentEmailContactEntry OBJECT-TYPE
+ SYNTAX TlpAgentEmailContactEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing the details of an email contact."
+ INDEX { tlpAgentEmailContactIndex }
+ ::= { tlpAgentEmailContactTable 1 }
+
+TlpAgentEmailContactEntry ::= SEQUENCE {
+ tlpAgentEmailContactIndex Unsigned32,
+ tlpAgentEmailContactRowStatus RowStatus,
+ tlpAgentEmailContactName DisplayString,
+ tlpAgentEmailContactAddress DisplayString }
+
+tlpAgentEmailContactIndex OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The table row index for the email contact."
+ ::= { tlpAgentEmailContactEntry 1 }
+
+tlpAgentEmailContactRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Row status for the tlpAgentEmailContactTable."
+ ::= { tlpAgentEmailContactEntry 2 }
+
+tlpAgentEmailContactName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The name of the email contact."
+ ::= { tlpAgentEmailContactEntry 3 }
+
+tlpAgentEmailContactAddress OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The address of the email contact."
+ ::= { tlpAgentEmailContactEntry 4 }
+
+tlpAgentNumSnmpContacts OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of SNMP contacts currently defined in the agent."
+ ::= { tlpAgentSnmpContacts 1 }
+
+tlpAgentSnmpContactTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpAgentSnmpContactEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of SNMP contact entries. The number of entries is given by
+ the value of tlpAgentNumSnmpContacts."
+ ::= { tlpAgentSnmpContacts 2 }
+
+tlpAgentSnmpContactEntry OBJECT-TYPE
+ SYNTAX TlpAgentSnmpContactEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing the details of an SNMP contact."
+ INDEX { tlpAgentSnmpContactIndex }
+ ::= { tlpAgentSnmpContactTable 1 }
+
+TlpAgentSnmpContactEntry ::= SEQUENCE {
+ tlpAgentSnmpContactIndex Unsigned32,
+ tlpAgentSnmpContactRowStatus RowStatus,
+ tlpAgentSnmpContactName DisplayString,
+ tlpAgentSnmpContactIpAddress DisplayString,
+ tlpAgentSnmpContactPort Unsigned32,
+ tlpAgentSnmpContactSnmpVersion INTEGER,
+ tlpAgentSnmpContactSecurityName DisplayString,
+ tlpAgentSnmpContactPrivPassword DisplayString,
+ tlpAgentSnmpContactAuthPassword DisplayString }
+
+tlpAgentSnmpContactIndex OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The table row index for the SNMP contact."
+ ::= { tlpAgentSnmpContactEntry 1 }
+
+tlpAgentSnmpContactRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Row status for the tlpAgentSnmpContactTable."
+ ::= { tlpAgentSnmpContactEntry 2 }
+
+tlpAgentSnmpContactName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The name of the SNMP contact."
+ ::= { tlpAgentSnmpContactEntry 3 }
+
+tlpAgentSnmpContactIpAddress OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The IP address of the SNMP contact."
+ ::= { tlpAgentSnmpContactEntry 4 }
+
+tlpAgentSnmpContactPort OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The port of the SNMP contact."
+ ::= { tlpAgentSnmpContactEntry 5 }
+
+tlpAgentSnmpContactSnmpVersion OBJECT-TYPE
+ SYNTAX INTEGER {
+ snmpv1(1),
+ snmpv2c(2),
+ snmpv3(3) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The SNMP contact version to use for sending traps."
+ ::= { tlpAgentSnmpContactEntry 6 }
+
+tlpAgentSnmpContactSecurityName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The security name for the SNMP contact."
+ ::= { tlpAgentSnmpContactEntry 7 }
+tlpAgentSnmpContactPrivPassword OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS obsolete
+ DESCRIPTION
+ "The privacy password to use for sending V3 traps to the SNMP
+ contact."
+ ::= { tlpAgentSnmpContactEntry 8 }
+tlpAgentSnmpContactAuthPassword OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS obsolete
+ DESCRIPTION
+ "The authentication password to use for sending V3 traps to the
+ SNMP contact."
+ ::= { tlpAgentSnmpContactEntry 9 }
+
+-- alarms
+
+tlpAlarmsPresent OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The present number of active alarm conditions."
+ ::= { tlpAlarms 1 }
+
+tlpAlarmTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpDeviceAlarmEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of alarm conditions for all devices managed by this agent. This
+ table contains zero, one, or many rows at any moment, depending upon
+ the number of alarm conditions in effect or conditions not acknowledged.
+ The agent creates a row in the table each time a condition is detected
+ and deletes that row when that condition no longer pertains (becomes
+ inactive and is acknowledged). The agent creates the first row with
+ tlpAlarmId equal to 1, and increments the value of tlpAlarmId each time
+ a new row is created, wrapping to the first free value greater than or
+ equal to 1 when the maximum value of tlpAlarmId would otherwise be
+ exceeded. Consequently, after multiple operations, the table may become
+ sparse (e.g., containing entries for rows 95, 100, 101, and 203) and the
+ entries should not be assumed to be in chronological order because
+ tlpAlarmId might have wrapped.
+
+ The number of rows in the table at any given time is reflected by
+ the value of tlpAlarmsPresent."
+ ::= { tlpAlarms 2 }
+
+tlpAlarmEntry OBJECT-TYPE
+ SYNTAX TlpDeviceAlarmEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing information application to a particular
+ alarm."
+ INDEX { tlpAlarmId }
+ ::= { tlpAlarmTable 1 }
+
+TlpDeviceAlarmEntry ::= SEQUENCE {
+ tlpAlarmId Unsigned32,
+ tlpAlarmDescr OBJECT IDENTIFIER,
+ tlpAlarmTime TimeStamp,
+ tlpAlarmTableRef OBJECT IDENTIFIER,
+ tlpAlarmTableRowRef OBJECT IDENTIFIER,
+ tlpAlarmDetail DisplayString,
+ tlpAlarmType INTEGER,
+ tlpAlarmState INTEGER,
+ tlpAlarmAcknowledged INTEGER }
+
+tlpAlarmId OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A unique identifier for an alarm condition. This value will remain
+ constant for the duration of the alarm condition."
+ ::= { tlpAlarmEntry 1 }
+
+tlpAlarmDescr OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A reference of the alarm description object. The object referenced
+ should not be accessible, but rather be used to provide a unique
+ description for the alarm condition. The object referenced will be a
+ well known alarm object associated with the device on which the alarm
+ condition is active."
+ ::= { tlpAlarmEntry 2 }
+
+tlpAlarmTime OBJECT-TYPE
+ SYNTAX TimeStamp
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value of sysUpTime when the alarm condition was detected. If the
+ alarm condition was detected at the time of agent startup and presumably
+ existed before agent startup, the value of tlpAlarmsTime shall equal
+ 0."
+ ::= { tlpAlarmEntry 3 }
+
+tlpAlarmTableRef OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This value references the OID of a table object applicable to the alarm
+ condition. This, in conjunction with the table row as defined by
+ tlpAlarmTableRowRef, specifies the object/row within this table to which
+ the alarm condition applies.
+
+ Example 1 -- The following sample values will be returned for a UPS on
+ battery:
+ tlpAlarmId 28
+ tlpAlarmDescr tlpUpsAlarmOnBattery
+ tlpAlarmTime 12345678
+ tlpAlarmTableRef tlpDeviceTable
+ tlpAlarmTableRowRef tlpDeviceIndex.2
+ tlpAlarmDetail On Battery
+ tlpAlarmType warning
+ tlpAlarmState active
+ tlpAlarmAcknowledged notAcknowledged
+
+ In the above example, tlpAlarmTableRef references the device table and
+ tlpAlarmTableRowRef references the 2nd managed device in that table.
+
+ Example 2 -- The following sample values will be returned for a PDU with
+ a load turned off:
+ tlpAlarmId 46
+ tlpAlarmDescr tlpPduAlarmLoadOff
+ tlpAlarmTime 12345678
+ tlpAlarmTableRef tlpPduOutletTable
+ tlpAlarmTableRowRef tlpOutletIndex.1.4
+ tlpAlarmDetail Load Off
+ tlpAlarmType warning
+ tlpAlarmState active
+ tlpAlarmAcknowledged acknowledged
+
+ In the above example, tlpAlarmTableRef references the pdu outlet table and
+ tlpAlarmTableRowRef references the 4th outlet on the 1st managed device."
+ ::= { tlpAlarmEntry 4 }
+
+tlpAlarmTableRowRef OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This value is used in conjunction with tlpAlarmTableRef to define the
+ object associated with this alarm condition. See the description of
+ tlpAlarmTableRef for more information."
+ ::= { tlpAlarmEntry 5 }
+
+tlpAlarmDetail OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A textual description of the alarm condition."
+ ::= { tlpAlarmEntry 6 }
+
+tlpAlarmType OBJECT-TYPE
+ SYNTAX INTEGER {
+ critical(1),
+ warning(2),
+ info(3),
+ status(4),
+ offline(5),
+ custom(6) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The category/group of this alarm."
+ ::= { tlpAlarmEntry 7 }
+
+tlpAlarmState OBJECT-TYPE
+ SYNTAX INTEGER {
+ active(1),
+ inactive(2) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current state of this alarm condition. An active(1) alarm is a condition
+ that currently exists. An inactive(2) alarm is a condition that no longer exists
+ because the alarm either cleared or was resolved. Each alarm condition must be
+ cleared and acknowledged before it is removed from this table (see
+ tlpAlarmAcknowledged)."
+ ::= { tlpAlarmEntry 8 }
+
+tlpAlarmAcknowledged OBJECT-TYPE
+ SYNTAX INTEGER {
+ notAcknowledged(1),
+ acknowledged(2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Denotes whether the alarm condition has been acknowledged. The agent will
+ return notAcknowledged(1) if the condition has not been acknowledged, or
+ acknowledged(2) when acknowledged. Writing the value acknowledged(2) for an
+ alarm acknowledges the alarm condition. Each alarm condition must be cleared
+ and acknowledged before it is removed from this table; therefore, even if
+ acknowledged, the alarm will remain in this table until the alarm becomes
+ inactive as denoted by tlpAlarmState."
+ ::= { tlpAlarmEntry 9 }
+
+tlpAlarmCommunicationsLost OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "A problem has been encountered in the communications between the agent
+ and the device."
+ ::= { tlpDeviceAlarms 1 }
+
+tlpAlarmUserDefined OBJECT IDENTIFIER
+ ::= { tlpDeviceAlarms 2 }
+
+tlpAlarmUserDefined01 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "User-defined event 1 is in alarm."
+ ::= { tlpAlarmUserDefined 1 }
+
+tlpAlarmUserDefined02 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "User-defined event 2 is in alarm."
+ ::= { tlpAlarmUserDefined 2 }
+
+tlpAlarmUserDefined03 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "User-defined event 3 is in alarm."
+ ::= { tlpAlarmUserDefined 3 }
+
+tlpAlarmUserDefined04 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "User-defined event 4 is in alarm."
+ ::= { tlpAlarmUserDefined 4 }
+
+tlpAlarmUserDefined05 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "User-defined event 5 is in alarm."
+ ::= { tlpAlarmUserDefined 5 }
+
+tlpAlarmUserDefined06 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "User-defined event 6 is in alarm."
+ ::= { tlpAlarmUserDefined 6 }
+
+tlpAlarmUserDefined07 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "User-defined event 7 is in alarm."
+ ::= { tlpAlarmUserDefined 7 }
+
+tlpAlarmUserDefined08 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "User-defined event 8 is in alarm."
+ ::= { tlpAlarmUserDefined 8 }
+
+tlpAlarmUserDefined09 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "User-defined event 9 is in alarm."
+ ::= { tlpAlarmUserDefined 9 }
+
+tlpAlarmInternalFirmwareError OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "A problem has been encountered with the device firmware."
+ ::= { tlpDeviceAlarms 3 }
+
+tlpAlarmDeviceEEPROMFault OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "A problem has been encountered with the device EEPROM."
+ ::= { tlpDeviceAlarms 4 }
+
+tlpUpsAlarmBatteryBad OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "One or more batteries have been determined to require replacement."
+ ::= { tlpUpsAlarms 1 }
+
+tlpUpsAlarmOnBattery OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The UPS is drawing power from the batteries."
+ ::= { tlpUpsAlarms 2 }
+
+tlpUpsAlarmLowBattery OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The remaining battery charge is less than or equal to the percentage of
+ capacity warning specified by tlpUpsConfigBatteryCapacityThreshold."
+ ::= { tlpUpsAlarms 3 }
+
+tlpUpsAlarmDepletedBattery OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The UPS will be unable to sustain the present load when and if
+ the utility power is lost."
+ ::= { tlpUpsAlarms 4 }
+
+tlpUpsAlarmTempBad OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "A temperature is out of tolerance."
+ ::= { tlpUpsAlarms 5 }
+
+tlpUpsAlarmInputBad OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "An input condition is out of tolerance."
+ ::= { tlpUpsAlarms 6 }
+
+tlpUpsAlarmOutputBad OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "An output condition (other than OutputOverload) is out of
+ tolerance."
+ ::= { tlpUpsAlarms 7 }
+
+tlpUpsAlarmOutputOverload OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The output load exceeds the UPS output capacity."
+ ::= { tlpUpsAlarms 8 }
+
+tlpUpsAlarmOnBypass OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The Bypass is presently engaged on the UPS."
+ ::= { tlpUpsAlarms 9 }
+
+tlpUpsAlarmBypassBad OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The Bypass is out of tolerance."
+ ::= { tlpUpsAlarms 10 }
+
+tlpUpsAlarmOutputOffAsRequested OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The UPS has shutdown as requested, i.e., the output is off."
+ ::= { tlpUpsAlarms 11 }
+
+tlpUpsAlarmUpsOffAsRequested OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The entire UPS has shutdown as commanded."
+ ::= { tlpUpsAlarms 12 }
+
+tlpUpsAlarmChargerFailed OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "An uncorrected problem has been detected within the UPS
+ charger subsystem."
+ ::= { tlpUpsAlarms 13 }
+
+tlpUpsAlarmUpsOutputOff OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The output of the UPS is in the off state."
+ ::= { tlpUpsAlarms 14 }
+
+tlpUpsAlarmUpsSystemOff OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The UPS system is in the off state."
+ ::= { tlpUpsAlarms 15 }
+
+tlpUpsAlarmFanFailure OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The failure of one or more fans in the UPS has been detected."
+ ::= { tlpUpsAlarms 16 }
+
+tlpUpsAlarmFuseFailure OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The failure of one or more fuses has been detected."
+ ::= { tlpUpsAlarms 17 }
+
+tlpUpsAlarmGeneralFault OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "A general fault in the UPS has been detected."
+ ::= { tlpUpsAlarms 18 }
+
+tlpUpsAlarmDiagnosticTestFailed OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The result of the last diagnostic test indicates a failure."
+ ::= { tlpUpsAlarms 19 }
+
+tlpUpsAlarmAwaitingPower OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The UPS output is off and the UPS is awaiting the return of
+ input power."
+ ::= { tlpUpsAlarms 20 }
+
+tlpUpsAlarmShutdownPending OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "A tlpUpsShutdownAfterDelay countdown is underway."
+ ::= { tlpUpsAlarms 21 }
+
+tlpUpsAlarmShutdownImminent OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The UPS will turn off power to the load in less than 5 seconds;
+ this may be either a timed shutdown or a low battery shutdown."
+ ::= { tlpUpsAlarms 22 }
+
+tlpUpsAlarmLoadLevelAboveThreshold OBJECT IDENTIFIER
+ ::= { tlpUpsAlarms 23 }
+
+tlpUpsAlarmLoadLevelAboveThresholdTotal OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The total load level is above the designated threshold."
+ ::= { tlpUpsAlarmLoadLevelAboveThreshold 1 }
+
+tlpUpsAlarmLoadLevelAboveThresholdPhase1 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The load level on phase 1 exceeds load limits."
+ ::= { tlpUpsAlarmLoadLevelAboveThreshold 2 }
+
+tlpUpsAlarmLoadLevelAboveThresholdPhase2 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The load level on phase 2 exceeds load limits."
+ ::= { tlpUpsAlarmLoadLevelAboveThreshold 3 }
+
+tlpUpsAlarmLoadLevelAboveThresholdPhase3 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The load level on phase 3 exceeds load limits."
+ ::= { tlpUpsAlarmLoadLevelAboveThreshold 4 }
+
+tlpUpsAlarmOutputCurrentChanged OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The output current changed from its last known value."
+ ::= { tlpUpsAlarms 24 }
+
+tlpUpsAlarmBatteryAgeAboveThreshold OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "One or more batteries have been determined to require replacement."
+ ::= { tlpUpsAlarms 25 }
+
+tlpUpsAlarmLoadOff OBJECT IDENTIFIER
+ ::= { tlpUpsAlarms 26 }
+
+tlpUpsAlarmLoadOff01 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 1 is off."
+ ::= { tlpUpsAlarmLoadOff 1 }
+
+tlpUpsAlarmLoadOff02 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 2 is off."
+ ::= { tlpUpsAlarmLoadOff 2 }
+
+tlpUpsAlarmLoadOff03 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 3 is off."
+ ::= { tlpUpsAlarmLoadOff 3 }
+
+tlpUpsAlarmLoadOff04 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 4 is off."
+ ::= { tlpUpsAlarmLoadOff 4 }
+
+tlpUpsAlarmLoadOff05 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 5 is off."
+ ::= { tlpUpsAlarmLoadOff 5 }
+
+tlpUpsAlarmLoadOff06 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 6 is off."
+ ::= { tlpUpsAlarmLoadOff 6 }
+
+tlpUpsAlarmLoadOff07 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 7 is off."
+ ::= { tlpUpsAlarmLoadOff 7 }
+
+tlpUpsAlarmLoadOff08 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 8 is off."
+ ::= { tlpUpsAlarmLoadOff 8 }
+
+tlpUpsAlarmLoadOff09 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 9 is off."
+ ::= { tlpUpsAlarmLoadOff 9 }
+
+tlpUpsAlarmLoadOff10 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 10 is off."
+ ::= { tlpUpsAlarmLoadOff 10 }
+
+tlpUpsAlarmLoadOff11 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 11 is off."
+ ::= { tlpUpsAlarmLoadOff 11 }
+
+tlpUpsAlarmLoadOff12 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 12 is off."
+ ::= { tlpUpsAlarmLoadOff 12 }
+
+tlpUpsAlarmLoadOff13 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 13 is off."
+ ::= { tlpUpsAlarmLoadOff 13 }
+
+tlpUpsAlarmLoadOff14 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 14 is off."
+ ::= { tlpUpsAlarmLoadOff 14 }
+
+tlpUpsAlarmLoadOff15 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 15 is off."
+ ::= { tlpUpsAlarmLoadOff 15 }
+
+tlpUpsAlarmLoadOff16 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 16 is off."
+ ::= { tlpUpsAlarmLoadOff 16 }
+
+tlpUpsAlarmLoadOff17 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 17 is off."
+ ::= { tlpUpsAlarmLoadOff 17 }
+
+tlpUpsAlarmLoadOff18 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 18 is off."
+ ::= { tlpUpsAlarmLoadOff 18 }
+
+tlpUpsAlarmLoadOff19 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 19 is off."
+ ::= { tlpUpsAlarmLoadOff 19 }
+
+tlpUpsAlarmLoadOff20 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 20 is off."
+ ::= { tlpUpsAlarmLoadOff 20 }
+
+tlpUpsAlarmLoadOff21 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 21 is off."
+ ::= { tlpUpsAlarmLoadOff 21 }
+
+tlpUpsAlarmLoadOff22 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 22 is off."
+ ::= { tlpUpsAlarmLoadOff 22 }
+
+tlpUpsAlarmLoadOff23 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 23 is off."
+ ::= { tlpUpsAlarmLoadOff 23 }
+
+tlpUpsAlarmLoadOff24 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 24 is off."
+ ::= { tlpUpsAlarmLoadOff 24 }
+
+tlpUpsAlarmLoadOff25 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 25 is off."
+ ::= { tlpUpsAlarmLoadOff 25 }
+
+tlpUpsAlarmLoadOff26 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 26 is off."
+ ::= { tlpUpsAlarmLoadOff 26 }
+
+tlpUpsAlarmLoadOff27 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 27 is off."
+ ::= { tlpUpsAlarmLoadOff 27 }
+
+tlpUpsAlarmLoadOff28 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 28 is off."
+ ::= { tlpUpsAlarmLoadOff 28 }
+
+tlpUpsAlarmLoadOff29 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 29 is off."
+ ::= { tlpUpsAlarmLoadOff 29 }
+
+tlpUpsAlarmLoadOff30 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 30 is off."
+ ::= { tlpUpsAlarmLoadOff 30 }
+
+tlpUpsAlarmLoadOff31 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 31 is off."
+ ::= { tlpUpsAlarmLoadOff 31 }
+
+tlpUpsAlarmLoadOff32 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 32 is off."
+ ::= { tlpUpsAlarmLoadOff 32 }
+
+tlpUpsAlarmLoadOff33 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 33 is off."
+ ::= { tlpUpsAlarmLoadOff 33 }
+
+tlpUpsAlarmLoadOff34 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 34 is off."
+ ::= { tlpUpsAlarmLoadOff 34 }
+
+tlpUpsAlarmLoadOff35 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 35 is off."
+ ::= { tlpUpsAlarmLoadOff 35 }
+
+tlpUpsAlarmLoadOff36 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 36 is off."
+ ::= { tlpUpsAlarmLoadOff 36 }
+
+tlpUpsAlarmLoadOff37 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 37 is off."
+ ::= { tlpUpsAlarmLoadOff 37 }
+
+tlpUpsAlarmLoadOff38 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 38 is off."
+ ::= { tlpUpsAlarmLoadOff 38 }
+
+tlpUpsAlarmLoadOff39 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 39 is off."
+ ::= { tlpUpsAlarmLoadOff 39 }
+
+tlpUpsAlarmLoadOff40 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 40 is off."
+ ::= { tlpUpsAlarmLoadOff 40 }
+
+tlpUpsAlarmCurrentAboveThreshold OBJECT IDENTIFIER
+ ::= { tlpUpsAlarms 27 }
+
+tlpUpsAlarmCurrentAboveThreshold1 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The output current on phase 1 exceeds load limits."
+ ::= { tlpUpsAlarmCurrentAboveThreshold 1 }
+
+tlpUpsAlarmCurrentAboveThreshold2 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The output current on phase 2 exceeds load limits."
+ ::= { tlpUpsAlarmCurrentAboveThreshold 2 }
+
+tlpUpsAlarmCurrentAboveThreshold3 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The output current on phase 3 exceeds load limits."
+ ::= { tlpUpsAlarmCurrentAboveThreshold 3 }
+
+tlpUpsAlarmRuntimeBelowWarningLevel OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The battery seconds remaining is below warning level."
+ ::= { tlpUpsAlarms 28 }
+
+tlpUpsAlarmBusStartVoltageLow OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The inverter start up bus voltage is too low."
+ ::= { tlpUpsAlarms 29 }
+
+tlpUpsAlarmBusOverVoltage OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The inverter bus voltage is too high."
+ ::= { tlpUpsAlarms 30 }
+
+tlpUpsAlarmBusUnderVoltage OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The inverter bus voltage is too low."
+ ::= { tlpUpsAlarms 31 }
+
+tlpUpsAlarmBusVoltageUnbalanced OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The inverter bus voltage is not balanced."
+ ::= { tlpUpsAlarms 32 }
+
+tlpUpsAlarmInverterSoftStartBad OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The inverter bus voltage cannot reach desired voltage within a
+ specified duration."
+ ::= { tlpUpsAlarms 33 }
+
+tlpUpsAlarmInverterOverVoltage OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The inverter voltage is too high."
+ ::= { tlpUpsAlarms 34 }
+
+tlpUpsAlarmInverterUnderVoltage OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The inverter voltage is too low."
+ ::= { tlpUpsAlarms 35 }
+
+tlpUpsAlarmInverterCircuitBad OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The inverter output is shorted."
+ ::= { tlpUpsAlarms 36 }
+
+tlpUpsAlarmBatteryOverVoltage OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The battery voltage is too high."
+ ::= { tlpUpsAlarms 37 }
+
+tlpUpsAlarmBatteryUnderVoltage OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The battery voltage is too low."
+ ::= { tlpUpsAlarms 38 }
+
+tlpUpsAlarmSiteWiringFault OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The utility input wiring is faulty."
+ ::= { tlpUpsAlarms 39 }
+
+tlpUpsAlarmOverTemperatureProtection OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The over temperature protection is activated."
+ ::= { tlpUpsAlarms 40 }
+
+tlpUpsAlarmOverCharged OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The UPS is over charged."
+ ::= { tlpUpsAlarms 41 }
+
+tlpUpsAlarmEPOActive OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The EPO is currently activated."
+ ::= { tlpUpsAlarms 42 }
+
+tlpUpsAlarmBypassFrequencyBad OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The bypass frequency is out of tolerance."
+ ::= { tlpUpsAlarms 43 }
+
+tlpUpsAlarmExternalSmartBatteryAgeAboveThreshold OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "One or more external smart batteries have been determined to require
+ replacement."
+ ::= { tlpUpsAlarms 44 }
+
+tlpUpsAlarmExternalNonSmartBatteryAgeAboveThreshold OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "One or more external non-smart batteries have been determined to require
+ replacement."
+ ::= { tlpUpsAlarms 45 }
+
+tlpUpsAlarmSmartBatteryCommLost OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Communications with the smart batteries was lost."
+ ::= { tlpUpsAlarms 46 }
+
+tlpUpsAlarmLoadsNotAllOn OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "One of more loads are not on."
+ ::= { tlpUpsAlarms 47 }
+
+tlpUpsAlarmBatteryTemperatureHigh OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The battery temperature is high."
+ ::= { tlpUpsAlarms 48 }
+
+tlpUpsAlarmBatteryTemperatureLow OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The battery temperature is low."
+ ::= { tlpUpsAlarms 49 }
+
+tlpUpsAlarmBatteryDisconnected OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The battery disconnected."
+ ::= { tlpUpsAlarms 50 }
+
+tlpUpsAlarmBatteryTemperatureSensorDisconnected OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The battery temperature sensor disconnected."
+ ::= { tlpUpsAlarms 51 }
+
+tlpUpsAlarmTemperatureDerating OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Power derating due to high environment temperature."
+ ::= { tlpUpsAlarms 52 }
+
+tlpUpsAlarmInputContact OBJECT IDENTIFIER
+ ::= { tlpUpsAlarms 53 }
+
+tlpUpsAlarmInputContact1 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Input contact 1 in alarm."
+ ::= { tlpUpsAlarmInputContact 1 }
+
+tlpUpsAlarmOutputContact OBJECT IDENTIFIER
+ ::= { tlpUpsAlarms 54 }
+
+tlpUpsAlarmOutputContact1 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Output contact 1 in alarm."
+ ::= { tlpUpsAlarmOutputContact 1 }
+
+tlpUpsAlarmOutputContact2 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Output contact 2 in alarm."
+ ::= { tlpUpsAlarmOutputContact 2 }
+
+tlpUpsAlarmOutputContact3 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Output contact 3 in alarm."
+ ::= { tlpUpsAlarmOutputContact 3 }
+
+tlpUpsAlarmOutputContact4 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Output contact 4 in alarm."
+ ::= { tlpUpsAlarmOutputContact 4 }
+
+tlpUpsAlarmOutputContact5 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Output contact 5 in alarm."
+ ::= { tlpUpsAlarmOutputContact 5 }
+
+tlpUpsAlarmOutputContact6 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Output contact 6 in alarm."
+ ::= { tlpUpsAlarmOutputContact 6 }
+
+tlpPduAlarmLoadLevelAboveThreshold OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The load level is above the designated threshold."
+ ::= { tlpPduAlarms 1 }
+
+tlpPduAlarmInputBad OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "An input condition is out of tolerance."
+ ::= { tlpPduAlarms 2 }
+
+tlpPduAlarmOutputBad OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "An output condition (other than OutputOverload) is out of
+ tolerance."
+ ::= { tlpPduAlarms 3 }
+
+tlpPduAlarmOutputOverload OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The output load exceeds the pdu output capacity."
+ ::= { tlpPduAlarms 4 }
+
+tlpPduAlarmOutputOff OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The output of the pdu is in the off state."
+ ::= { tlpPduAlarms 5 }
+
+tlpPduAlarmLoadOff OBJECT IDENTIFIER
+ ::= { tlpPduAlarms 6 }
+
+tlpPduAlarmLoadOff01 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 1 is off."
+ ::= { tlpPduAlarmLoadOff 1 }
+
+tlpPduAlarmLoadOff02 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 2 is off."
+ ::= { tlpPduAlarmLoadOff 2 }
+
+tlpPduAlarmLoadOff03 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 3 is off."
+ ::= { tlpPduAlarmLoadOff 3 }
+
+tlpPduAlarmLoadOff04 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 4 is off."
+ ::= { tlpPduAlarmLoadOff 4 }
+
+tlpPduAlarmLoadOff05 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 5 is off."
+ ::= { tlpPduAlarmLoadOff 5 }
+
+tlpPduAlarmLoadOff06 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 6 is off."
+ ::= { tlpPduAlarmLoadOff 6 }
+
+tlpPduAlarmLoadOff07 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 7 is off."
+ ::= { tlpPduAlarmLoadOff 7 }
+
+tlpPduAlarmLoadOff08 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 8 is off."
+ ::= { tlpPduAlarmLoadOff 8 }
+
+tlpPduAlarmLoadOff09 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 9 is off."
+ ::= { tlpPduAlarmLoadOff 9 }
+
+tlpPduAlarmLoadOff10 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 10 is off."
+ ::= { tlpPduAlarmLoadOff 10 }
+
+tlpPduAlarmLoadOff11 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 11 is off."
+ ::= { tlpPduAlarmLoadOff 11 }
+
+tlpPduAlarmLoadOff12 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 12 is off."
+ ::= { tlpPduAlarmLoadOff 12 }
+
+tlpPduAlarmLoadOff13 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 13 is off."
+ ::= { tlpPduAlarmLoadOff 13 }
+
+tlpPduAlarmLoadOff14 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 14 is off."
+ ::= { tlpPduAlarmLoadOff 14 }
+
+tlpPduAlarmLoadOff15 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 15 is off."
+ ::= { tlpPduAlarmLoadOff 15 }
+
+tlpPduAlarmLoadOff16 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 16 is off."
+ ::= { tlpPduAlarmLoadOff 16 }
+
+tlpPduAlarmLoadOff17 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 17 is off."
+ ::= { tlpPduAlarmLoadOff 17 }
+
+tlpPduAlarmLoadOff18 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 18 is off."
+ ::= { tlpPduAlarmLoadOff 18 }
+
+tlpPduAlarmLoadOff19 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 19 is off."
+ ::= { tlpPduAlarmLoadOff 19 }
+
+tlpPduAlarmLoadOff20 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 20 is off."
+ ::= { tlpPduAlarmLoadOff 20 }
+
+tlpPduAlarmLoadOff21 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 21 is off."
+ ::= { tlpPduAlarmLoadOff 21 }
+
+tlpPduAlarmLoadOff22 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 22 is off."
+ ::= { tlpPduAlarmLoadOff 22 }
+
+tlpPduAlarmLoadOff23 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 23 is off."
+ ::= { tlpPduAlarmLoadOff 23 }
+
+tlpPduAlarmLoadOff24 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 24 is off."
+ ::= { tlpPduAlarmLoadOff 24 }
+
+tlpPduAlarmLoadOff25 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 25 is off."
+ ::= { tlpPduAlarmLoadOff 25 }
+
+tlpPduAlarmLoadOff26 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 26 is off."
+ ::= { tlpPduAlarmLoadOff 26 }
+
+tlpPduAlarmLoadOff27 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 27 is off."
+ ::= { tlpPduAlarmLoadOff 27 }
+
+tlpPduAlarmLoadOff28 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 28 is off."
+ ::= { tlpPduAlarmLoadOff 28 }
+
+tlpPduAlarmLoadOff29 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 29 is off."
+ ::= { tlpPduAlarmLoadOff 29 }
+
+tlpPduAlarmLoadOff30 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 30 is off."
+ ::= { tlpPduAlarmLoadOff 30 }
+
+tlpPduAlarmLoadOff31 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 31 is off."
+ ::= { tlpPduAlarmLoadOff 31 }
+
+tlpPduAlarmLoadOff32 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 32 is off."
+ ::= { tlpPduAlarmLoadOff 32 }
+
+tlpPduAlarmLoadOff33 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 33 is off."
+ ::= { tlpPduAlarmLoadOff 33 }
+
+tlpPduAlarmLoadOff34 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 34 is off."
+ ::= { tlpPduAlarmLoadOff 34 }
+
+tlpPduAlarmLoadOff35 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 35 is off."
+ ::= { tlpPduAlarmLoadOff 35 }
+
+tlpPduAlarmLoadOff36 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 36 is off."
+ ::= { tlpPduAlarmLoadOff 36 }
+
+tlpPduAlarmLoadOff37 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 37 is off."
+ ::= { tlpPduAlarmLoadOff 37 }
+
+tlpPduAlarmLoadOff38 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 38 is off."
+ ::= { tlpPduAlarmLoadOff 38 }
+
+tlpPduAlarmLoadOff39 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 39 is off."
+ ::= { tlpPduAlarmLoadOff 39 }
+
+tlpPduAlarmLoadOff40 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 40 is off."
+ ::= { tlpPduAlarmLoadOff 40 }
+
+tlpPduAlarmCircuitBreakerOpen OBJECT IDENTIFIER
+ ::= { tlpPduAlarms 7 }
+
+tlpPduAlarmCircuitBreakerOpen01 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Circuit breaker 1 is open."
+ ::= { tlpPduAlarmCircuitBreakerOpen 1 }
+
+tlpPduAlarmCircuitBreakerOpen02 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Circuit breaker 2 is open."
+ ::= { tlpPduAlarmCircuitBreakerOpen 2 }
+
+tlpPduAlarmCircuitBreakerOpen03 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Circuit breaker 3 is open."
+ ::= { tlpPduAlarmCircuitBreakerOpen 3 }
+
+tlpPduAlarmCircuitBreakerOpen04 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Circuit breaker 4 is open."
+ ::= { tlpPduAlarmCircuitBreakerOpen 4 }
+
+tlpPduAlarmCircuitBreakerOpen05 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Circuit breaker 5 is open."
+ ::= { tlpPduAlarmCircuitBreakerOpen 5 }
+
+tlpPduAlarmCircuitBreakerOpen06 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Circuit breaker 6 is open."
+ ::= { tlpPduAlarmCircuitBreakerOpen 6 }
+
+tlpPduAlarmCurrentAboveThreshold OBJECT IDENTIFIER
+ ::= { tlpPduAlarms 8 }
+
+tlpPduAlarmCurrentAboveThreshold1 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The output current on phase 1 exceeds load limits."
+ ::= { tlpPduAlarmCurrentAboveThreshold 1 }
+
+tlpPduAlarmCurrentAboveThreshold2 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The output current on phase 2 exceeds load limits."
+ ::= { tlpPduAlarmCurrentAboveThreshold 2 }
+
+tlpPduAlarmCurrentAboveThreshold3 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The output current on phase 3 exceeds load limits."
+ ::= { tlpPduAlarmCurrentAboveThreshold 3 }
+
+tlpPduAlarmLoadsNotAllOn OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "One of more loads are not on."
+ ::= { tlpPduAlarms 9 }
+
+tlpPduAlarmLoadLevelBelowThreshold OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The load level is below the designated threshold."
+ ::= { tlpPduAlarms 10 }
+
+tlpPduAlarmCurrentBelowThreshold OBJECT IDENTIFIER
+ ::= { tlpPduAlarms 11 }
+
+tlpPduAlarmCurrentBelowThreshold1 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The output current on phase 1 below load limits."
+ ::= { tlpPduAlarmCurrentBelowThreshold 1 }
+
+tlpPduAlarmCurrentBelowThreshold2 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The output current on phase 2 below load limits."
+ ::= { tlpPduAlarmCurrentBelowThreshold 2 }
+
+tlpPduAlarmCurrentBelowThreshold3 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The output current on phase 3 below load limits."
+ ::= { tlpPduAlarmCurrentBelowThreshold 3 }
+
+tlpEnvAlarmTemperatureBeyondLimits OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The temperature exceeds limits."
+ ::= { tlpEnvAlarms 1 }
+
+tlpEnvAlarmHumidityBeyondLimits OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The humidity exceeds limits."
+ ::= { tlpEnvAlarms 2 }
+
+tlpEnvAlarmInputContact OBJECT IDENTIFIER
+ ::= { tlpEnvAlarms 3 }
+
+tlpEnvAlarmInputContact01 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Input contact 1 is in alarm."
+ ::= { tlpEnvAlarmInputContact 1 }
+
+tlpEnvAlarmInputContact02 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Input contact 2 is in alarm."
+ ::= { tlpEnvAlarmInputContact 2 }
+
+tlpEnvAlarmInputContact03 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Input contact 3 is in alarm."
+ ::= { tlpEnvAlarmInputContact 3 }
+
+tlpEnvAlarmInputContact04 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Input contact 4 is in alarm."
+ ::= { tlpEnvAlarmInputContact 4 }
+
+tlpEnvAlarmOutputContact OBJECT IDENTIFIER
+ ::= { tlpEnvAlarms 4 }
+
+tlpEnvAlarmOutputContact01 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Output contact 1 is in alarm."
+ ::= { tlpEnvAlarmOutputContact 1 }
+
+tlpEnvAlarmOutputContact02 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Output contact 2 is in alarm."
+ ::= { tlpEnvAlarmOutputContact 2 }
+
+tlpEnvAlarmOutputContact03 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Output contact 3 is in alarm."
+ ::= { tlpEnvAlarmOutputContact 3 }
+
+tlpEnvAlarmOutputContact04 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Output contact 4 is in alarm."
+ ::= { tlpEnvAlarmOutputContact 4 }
+
+tlpAtsAlarmOutage OBJECT IDENTIFIER
+ ::= { tlpAtsAlarms 1 }
+
+tlpAtsAlarmSource1Outage OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Input on source 1 is not present. For atss with the designation
+ of primary and secondary, this alarm denotes input on the primary
+ source is not present."
+ ::= { tlpAtsAlarmOutage 1 }
+
+tlpAtsAlarmSource2Outage OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Input on source 2 is not present. For atss with the designation
+ of primary and secondary, this alarm denotes input on the secondary
+ source is not present."
+ ::= { tlpAtsAlarmOutage 2 }
+
+tlpAtsAlarmTemperature OBJECT IDENTIFIER
+ ::= { tlpAtsAlarms 2 }
+
+tlpAtsAlarmSystemTemperature OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The system temperature is out of tolerance."
+ ::= { tlpAtsAlarmTemperature 1 }
+
+tlpAtsAlarmSource1Temperature OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The source 1 temperature is out of tolerance."
+ ::= { tlpAtsAlarmTemperature 2 }
+
+tlpAtsAlarmSource2Temperature OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The source 2 temperature is out of tolerance."
+ ::= { tlpAtsAlarmTemperature 3 }
+
+tlpAtsAlarmLoadLevelAboveThreshold OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The load level is above the designated threshold."
+ ::= { tlpAtsAlarms 3 }
+
+tlpAtsAlarmInputBad OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "An input condition is out of tolerance."
+ ::= { tlpAtsAlarms 4 }
+
+tlpAtsAlarmOutputBad OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "An output condition (other than OutputOverload) is out of
+ tolerance."
+ ::= { tlpAtsAlarms 5 }
+
+tlpAtsAlarmOutputOverload OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The output load exceeds the ats output capacity."
+ ::= { tlpAtsAlarms 6 }
+
+tlpAtsAlarmOutputOff OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The output of the ats is in the off state."
+ ::= { tlpAtsAlarms 7 }
+
+tlpAtsAlarmLoadOff OBJECT IDENTIFIER
+ ::= { tlpAtsAlarms 8 }
+
+tlpAtsAlarmLoadOff01 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 1 is off."
+ ::= { tlpAtsAlarmLoadOff 1 }
+
+tlpAtsAlarmLoadOff02 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 2 is off."
+ ::= { tlpAtsAlarmLoadOff 2 }
+
+tlpAtsAlarmLoadOff03 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 3 is off."
+ ::= { tlpAtsAlarmLoadOff 3 }
+
+tlpAtsAlarmLoadOff04 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 4 is off."
+ ::= { tlpAtsAlarmLoadOff 4 }
+
+tlpAtsAlarmLoadOff05 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 5 is off."
+ ::= { tlpAtsAlarmLoadOff 5 }
+
+tlpAtsAlarmLoadOff06 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 6 is off."
+ ::= { tlpAtsAlarmLoadOff 6 }
+
+tlpAtsAlarmLoadOff07 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 7 is off."
+ ::= { tlpAtsAlarmLoadOff 7 }
+
+tlpAtsAlarmLoadOff08 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 8 is off."
+ ::= { tlpAtsAlarmLoadOff 8 }
+
+tlpAtsAlarmLoadOff09 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 9 is off."
+ ::= { tlpAtsAlarmLoadOff 9 }
+
+tlpAtsAlarmLoadOff10 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 10 is off."
+ ::= { tlpAtsAlarmLoadOff 10 }
+
+tlpAtsAlarmLoadOff11 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 11 is off."
+ ::= { tlpAtsAlarmLoadOff 11 }
+
+tlpAtsAlarmLoadOff12 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 12 is off."
+ ::= { tlpAtsAlarmLoadOff 12 }
+
+tlpAtsAlarmLoadOff13 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 13 is off."
+ ::= { tlpAtsAlarmLoadOff 13 }
+
+tlpAtsAlarmLoadOff14 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 14 is off."
+ ::= { tlpAtsAlarmLoadOff 14 }
+
+tlpAtsAlarmLoadOff15 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 15 is off."
+ ::= { tlpAtsAlarmLoadOff 15 }
+
+tlpAtsAlarmLoadOff16 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 16 is off."
+ ::= { tlpAtsAlarmLoadOff 16 }
+
+tlpAtsAlarmLoadOff17 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 17 is off."
+ ::= { tlpAtsAlarmLoadOff 17 }
+
+tlpAtsAlarmLoadOff18 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 18 is off."
+ ::= { tlpAtsAlarmLoadOff 18 }
+
+tlpAtsAlarmLoadOff19 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 19 is off."
+ ::= { tlpAtsAlarmLoadOff 19 }
+
+tlpAtsAlarmLoadOff20 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 20 is off."
+ ::= { tlpAtsAlarmLoadOff 20 }
+
+tlpAtsAlarmLoadOff21 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 21 is off."
+ ::= { tlpAtsAlarmLoadOff 21 }
+
+tlpAtsAlarmLoadOff22 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 22 is off."
+ ::= { tlpAtsAlarmLoadOff 22 }
+
+tlpAtsAlarmLoadOff23 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 23 is off."
+ ::= { tlpAtsAlarmLoadOff 23 }
+
+tlpAtsAlarmLoadOff24 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 24 is off."
+ ::= { tlpAtsAlarmLoadOff 24 }
+
+tlpAtsAlarmLoadOff25 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 25 is off."
+ ::= { tlpAtsAlarmLoadOff 25 }
+
+tlpAtsAlarmLoadOff26 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 26 is off."
+ ::= { tlpAtsAlarmLoadOff 26 }
+
+tlpAtsAlarmLoadOff27 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 27 is off."
+ ::= { tlpAtsAlarmLoadOff 27 }
+
+tlpAtsAlarmLoadOff28 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 28 is off."
+ ::= { tlpAtsAlarmLoadOff 28 }
+
+tlpAtsAlarmLoadOff29 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 29 is off."
+ ::= { tlpAtsAlarmLoadOff 29 }
+
+tlpAtsAlarmLoadOff30 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 30 is off."
+ ::= { tlpAtsAlarmLoadOff 30 }
+
+tlpAtsAlarmLoadOff31 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 31 is off."
+ ::= { tlpAtsAlarmLoadOff 31 }
+
+tlpAtsAlarmLoadOff32 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 32 is off."
+ ::= { tlpAtsAlarmLoadOff 32 }
+
+tlpAtsAlarmLoadOff33 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 33 is off."
+ ::= { tlpAtsAlarmLoadOff 33 }
+
+tlpAtsAlarmLoadOff34 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 34 is off."
+ ::= { tlpAtsAlarmLoadOff 34 }
+
+tlpAtsAlarmLoadOff35 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 35 is off."
+ ::= { tlpAtsAlarmLoadOff 35 }
+
+tlpAtsAlarmLoadOff36 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 36 is off."
+ ::= { tlpAtsAlarmLoadOff 36 }
+
+tlpAtsAlarmLoadOff37 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 37 is off."
+ ::= { tlpAtsAlarmLoadOff 37 }
+
+tlpAtsAlarmLoadOff38 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 38 is off."
+ ::= { tlpAtsAlarmLoadOff 38 }
+
+tlpAtsAlarmLoadOff39 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 39 is off."
+ ::= { tlpAtsAlarmLoadOff 39 }
+
+tlpAtsAlarmLoadOff40 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Load 40 is off."
+ ::= { tlpAtsAlarmLoadOff 40 }
+
+tlpAtsAlarmCircuitBreakerOpen OBJECT IDENTIFIER
+ ::= { tlpAtsAlarms 9 }
+
+tlpAtsAlarmCircuitBreakerOpen01 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Circuit breaker 1 is open."
+ ::= { tlpAtsAlarmCircuitBreakerOpen 1 }
+
+tlpAtsAlarmCircuitBreakerOpen02 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Circuit breaker 2 is open."
+ ::= { tlpAtsAlarmCircuitBreakerOpen 2 }
+
+tlpAtsAlarmCircuitBreakerOpen03 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Circuit breaker 3 is open."
+ ::= { tlpAtsAlarmCircuitBreakerOpen 3 }
+
+tlpAtsAlarmCircuitBreakerOpen04 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Circuit breaker 4 is open."
+ ::= { tlpAtsAlarmCircuitBreakerOpen 4 }
+
+tlpAtsAlarmCircuitBreakerOpen05 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Circuit breaker 5 is open."
+ ::= { tlpAtsAlarmCircuitBreakerOpen 5 }
+
+tlpAtsAlarmCircuitBreakerOpen06 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Circuit breaker 6 is open."
+ ::= { tlpAtsAlarmCircuitBreakerOpen 6 }
+
+tlpAtsAlarmCurrentAboveThreshold OBJECT IDENTIFIER
+ ::= { tlpAtsAlarms 10 }
+
+tlpAtsAlarmCurrentAboveThresholdA1 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The output current on input source 1 phase 1 exceeds load limits."
+ ::= { tlpAtsAlarmCurrentAboveThreshold 1 }
+
+tlpAtsAlarmCurrentAboveThresholdA2 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The output current on input source 1 phase 2 exceeds load limits."
+ ::= { tlpAtsAlarmCurrentAboveThreshold 2 }
+
+tlpAtsAlarmCurrentAboveThresholdA3 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The output current on input source 1 phase 3 exceeds load limits."
+ ::= { tlpAtsAlarmCurrentAboveThreshold 3 }
+
+tlpAtsAlarmCurrentAboveThresholdB1 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The output current on input source 2 phase 1 exceeds load limits."
+ ::= { tlpAtsAlarmCurrentAboveThreshold 4 }
+
+tlpAtsAlarmCurrentAboveThresholdB2 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The output current on input source 2 phase 2 exceeds load limits."
+ ::= { tlpAtsAlarmCurrentAboveThreshold 5 }
+
+tlpAtsAlarmCurrentAboveThresholdB3 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The output current on input source 2 phase 3 exceeds load limits."
+ ::= { tlpAtsAlarmCurrentAboveThreshold 6 }
+
+tlpAtsAlarmLoadsNotAllOn OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "One of more loads are not on."
+ ::= { tlpAtsAlarms 11 }
+
+tlpAtsAlarmGeneralFault OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "A general fault in the ats has been detected."
+ ::= { tlpAtsAlarms 12 }
+
+tlpAtsAlarmVoltage OBJECT IDENTIFIER
+ ::= { tlpAtsAlarms 13 }
+
+tlpAtsAlarmOverVoltage OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The input voltage is out of tolerance."
+ ::= { tlpAtsAlarmVoltage 1 }
+
+tlpAtsAlarmSource1OverVoltage OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The voltage on source 1 is out of tolerance."
+ ::= { tlpAtsAlarmVoltage 2 }
+
+tlpAtsAlarmSource2OverVoltage OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The voltage on source 2 is out of tolerance."
+ ::= { tlpAtsAlarmVoltage 3 }
+
+tlpAtsAlarmFrequency OBJECT IDENTIFIER
+ ::= { tlpAtsAlarms 14 }
+
+tlpAtsAlarmSource1InvalidFrequency OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The voltage on source 1 is out of tolerance."
+ ::= { tlpAtsAlarmFrequency 1 }
+
+tlpAtsAlarmSource2InvalidFrequency OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The voltage on source 2 is out of tolerance."
+ ::= { tlpAtsAlarmFrequency 2 }
+
+tlpAtsAlarmLoadLevelBelowThreshold OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The load level is below the designated threshold."
+ ::= { tlpAtsAlarms 15 }
+
+tlpAtsAlarmCurrentBelowThreshold OBJECT IDENTIFIER
+ ::= { tlpAtsAlarms 16 }
+
+tlpAtsAlarmCurrentBelowThresholdA1 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The output current on input source 1 phase 1 below load limits."
+ ::= { tlpAtsAlarmCurrentBelowThreshold 1 }
+
+tlpAtsAlarmCurrentBelowThresholdA2 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The output current on input source 1 phase 2 below load limits."
+ ::= { tlpAtsAlarmCurrentBelowThreshold 2 }
+
+tlpAtsAlarmCurrentBelowThresholdA3 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The output current on input source 1 phase 3 below load limits."
+ ::= { tlpAtsAlarmCurrentBelowThreshold 3 }
+
+tlpAtsAlarmCurrentBelowThresholdB1 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The output current on input source 2 phase 1 below load limits."
+ ::= { tlpAtsAlarmCurrentBelowThreshold 4 }
+
+tlpAtsAlarmCurrentBelowThresholdB2 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The output current on input source 2 phase 2 below load limits."
+ ::= { tlpAtsAlarmCurrentBelowThreshold 5 }
+
+tlpAtsAlarmCurrentBelowThresholdB3 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The output current on input source 2 phase 3 below load limits."
+ ::= { tlpAtsAlarmCurrentBelowThreshold 6 }
+
+tlpCoolingAlarmSupplyAirSensorFault OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The supply air sensor is in fault."
+ ::= { tlpCoolingAlarms 1 }
+
+tlpCoolingAlarmReturnAirSensorFault OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The return air sensor is in fault."
+ ::= { tlpCoolingAlarms 2 }
+
+tlpCoolingAlarmCondenserInletAirSensorFault OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The condenser inlet air sensor is in fault."
+ ::= { tlpCoolingAlarms 3 }
+
+tlpCoolingAlarmCondenserOutletAirSensorFault OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The condenser outlet air sensor is in fault."
+ ::= { tlpCoolingAlarms 4 }
+
+tlpCoolingAlarmSuctionTemperatureSensorFault OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The suction temperature sensor is in fault."
+ ::= { tlpCoolingAlarms 5 }
+
+tlpCoolingAlarmEvaporatorTemperatureSensorFault OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The evaporator temperature sensor is in fault."
+ ::= { tlpCoolingAlarms 6 }
+
+tlpCoolingAlarmAirFilterClogged OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The air filter is clogged."
+ ::= { tlpCoolingAlarms 7 }
+
+tlpCoolingAlarmAirFilterRunHoursViolation OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The air filter run hours was violated."
+ ::= { tlpCoolingAlarms 8 }
+
+tlpCoolingAlarmSuctionPressureSensorFault OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The suction pressure sensor is in fault."
+ ::= { tlpCoolingAlarms 9 }
+
+tlpCoolingAlarmInverterCommunicationsFault OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The inverter communications is in fault."
+ ::= { tlpCoolingAlarms 10 }
+
+tlpCoolingAlarmRemoteShutdownViaInputContact OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "A remote shutdown was triggerd by an input contact."
+ ::= { tlpCoolingAlarms 11 }
+
+tlpCoolingAlarmCondensatePumpFault OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The condensate pump is in fault."
+ ::= { tlpCoolingAlarms 12 }
+
+tlpCoolingAlarmLowRefrigerantStartupFault OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The low refrigerant startup is in fault."
+ ::= { tlpCoolingAlarms 13 }
+
+tlpCoolingAlarmCondenserFanFault OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The condenser fan is in fault."
+ ::= { tlpCoolingAlarms 14 }
+
+tlpCoolingAlarmCondenserFailure OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The condenser has failed."
+ ::= { tlpCoolingAlarms 15 }
+
+tlpCoolingAlarmEvaporatorCoolingFailure OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The evaporator cooling is in fault."
+ ::= { tlpCoolingAlarms 16 }
+
+tlpCoolingAlarmReturnAirTempHigh OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The return air temperature is high."
+ ::= { tlpCoolingAlarms 17 }
+
+tlpCoolingAlarmSupplyAirTempHigh OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The supply air temperature is high."
+ ::= { tlpCoolingAlarms 18 }
+
+tlpCoolingAlarmEvaporatorFailure OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The evaporator has failed."
+ ::= { tlpCoolingAlarms 19 }
+
+tlpCoolingAlarmEvaporatorFreezeUp OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The evaporator is frozen."
+ ::= { tlpCoolingAlarms 20 }
+
+tlpCoolingAlarmDischargePressureHigh OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The discharge pressure is high."
+ ::= { tlpCoolingAlarms 21 }
+
+tlpCoolingAlarmPressureGaugeFailure OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The pressure gauge has failed."
+ ::= { tlpCoolingAlarms 22 }
+
+tlpCoolingAlarmDischargePressurePersistentHigh OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The discharge pressure is persistently high."
+ ::= { tlpCoolingAlarms 23 }
+
+tlpCoolingAlarmSuctionPressureLowStartFailure OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Cannot start due to low suction pressure."
+ ::= { tlpCoolingAlarms 24 }
+
+tlpCoolingAlarmSuctionPressureLow OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The suction pressure is low."
+ ::= { tlpCoolingAlarms 25 }
+
+tlpCoolingAlarmSuctionPressurePersistentLow OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The suction pressure is persistently low."
+ ::= { tlpCoolingAlarms 26 }
+
+tlpCoolingAlarmStartupLinePressureImbalance OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The startup line pressure is in imbalance."
+ ::= { tlpCoolingAlarms 27 }
+
+tlpCoolingAlarmCompressorFailure OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The compressor has failed."
+ ::= { tlpCoolingAlarms 28 }
+
+tlpCoolingAlarmCurrentLimit OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The current is out of range."
+ ::= { tlpCoolingAlarms 29 }
+
+tlpCoolingAlarmWaterLeak OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Water is leaking."
+ ::= { tlpCoolingAlarms 30 }
+
+tlpCoolingAlarmFanUnderCurrent OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The fan is under current."
+ ::= { tlpCoolingAlarms 31 }
+
+tlpCoolingAlarmFanOverCurrent OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The fan is over current."
+ ::= { tlpCoolingAlarms 32 }
+
+tlpCoolingAlarmDischargePressureSensorFault OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The discharge pressure sensor is in fault."
+ ::= { tlpCoolingAlarms 33 }
+
+tlpCoolingAlarmWaterFull OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Water is Full."
+ ::= { tlpCoolingAlarms 34 }
+
+tlpCoolingAlarmAutoCoolingOn OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Automatic cooling was activated to lower the temperature below the
+ remote set point."
+ ::= { tlpCoolingAlarms 35 }
+
+tlpCoolingAlarmPowerButtonPressed OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Power button was pressed on the front panel."
+ ::= { tlpCoolingAlarms 36 }
+
+tlpCoolingAlarmDisconnectedFromDevice OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "The device communications is disconnected."
+ ::= { tlpCoolingAlarms 37 }
+
+tlpCoolingAlarmAmbientTemperatureSensorFault OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Ambient temperature sensor is in fault."
+ ::= { tlpCoolingAlarms 38 }
+
+tlpCoolingAlarmRemoteTemperatureSensorFault OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Remote temperature sensor is in fault."
+ ::= { tlpCoolingAlarms 39 }
+
+tlpCoolingAlarmLowPressureSensorFault OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Low pressure sensor is in fault."
+ ::= { tlpCoolingAlarms 40 }
+
+tlpCoolingAlarmHighPressureSensorFault OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "High pressure sensor is in fault."
+ ::= { tlpCoolingAlarms 41 }
+
+tlpCoolingAlarmSentrytimerTimeout OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Sentry timer time out."
+ ::= { tlpCoolingAlarms 42 }
+
+tlpAutoProbeAlarms OBJECT IDENTIFIER
+ ::= { tlpAgentAlarms 1 }
+
+tlpAutoProbeAlarm01 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 1 had failed"
+ ::= { tlpAutoProbeAlarms 1 }
+
+tlpAutoProbeAlarm02 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 2 had failed"
+ ::= { tlpAutoProbeAlarms 2 }
+
+tlpAutoProbeAlarm03 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 3 had failed"
+ ::= { tlpAutoProbeAlarms 3 }
+
+tlpAutoProbeAlarm04 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 4 had failed"
+ ::= { tlpAutoProbeAlarms 4 }
+
+tlpAutoProbeAlarm05 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 5 had failed"
+ ::= { tlpAutoProbeAlarms 5 }
+
+tlpAutoProbeAlarm06 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 6 had failed"
+ ::= { tlpAutoProbeAlarms 6 }
+
+tlpAutoProbeAlarm07 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 7 had failed"
+ ::= { tlpAutoProbeAlarms 7 }
+
+tlpAutoProbeAlarm08 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 8 had failed"
+ ::= { tlpAutoProbeAlarms 8 }
+
+
+tlpAutoProbeAlarm09 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 9 had failed"
+ ::= { tlpAutoProbeAlarms 9 }
+
+tlpAutoProbeAlarm10 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 10 had failed"
+ ::= { tlpAutoProbeAlarms 10 }
+
+tlpAutoProbeAlarm11 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 11 had failed"
+ ::= { tlpAutoProbeAlarms 11 }
+
+tlpAutoProbeAlarm12 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 12 had failed"
+ ::= { tlpAutoProbeAlarms 12 }
+
+tlpAutoProbeAlarm13 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 13 had failed"
+ ::= { tlpAutoProbeAlarms 13 }
+
+tlpAutoProbeAlarm14 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 14 had failed"
+ ::= { tlpAutoProbeAlarms 14 }
+
+tlpAutoProbeAlarm15 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 15 had failed"
+ ::= { tlpAutoProbeAlarms 15 }
+
+tlpAutoProbeAlarm16 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 16 had failed"
+ ::= { tlpAutoProbeAlarms 16 }
+
+tlpAutoProbeAlarm17 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 17 had failed"
+ ::= { tlpAutoProbeAlarms 17 }
+
+tlpAutoProbeAlarm18 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 18 had failed"
+ ::= { tlpAutoProbeAlarms 18 }
+
+tlpAutoProbeAlarm19 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 19 had failed"
+ ::= { tlpAutoProbeAlarms 19 }
+
+tlpAutoProbeAlarm20 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 20 had failed"
+ ::= { tlpAutoProbeAlarms 20 }
+
+tlpAutoProbeAlarm21 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 21 had failed"
+ ::= { tlpAutoProbeAlarms 21 }
+
+tlpAutoProbeAlarm22 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 22 had failed"
+ ::= { tlpAutoProbeAlarms 22 }
+
+tlpAutoProbeAlarm23 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 23 had failed"
+ ::= { tlpAutoProbeAlarms 23 }
+
+tlpAutoProbeAlarm24 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 24 had failed"
+ ::= { tlpAutoProbeAlarms 24 }
+
+tlpAutoProbeAlarm25 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 25 had failed"
+ ::= { tlpAutoProbeAlarms 25 }
+
+tlpAutoProbeAlarm26 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 26 had failed"
+ ::= { tlpAutoProbeAlarms 26 }
+
+tlpAutoProbeAlarm27 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 27 had failed"
+ ::= { tlpAutoProbeAlarms 27 }
+
+tlpAutoProbeAlarm28 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 28 had failed"
+ ::= { tlpAutoProbeAlarms 28 }
+
+tlpAutoProbeAlarm29 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 29 had failed"
+ ::= { tlpAutoProbeAlarms 29 }
+
+tlpAutoProbeAlarm30 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 30 had failed"
+ ::= { tlpAutoProbeAlarms 30 }
+
+tlpAutoProbeAlarm31 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 31 had failed"
+ ::= { tlpAutoProbeAlarms 31 }
+
+tlpAutoProbeAlarm32 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 32 had failed"
+ ::= { tlpAutoProbeAlarms 32 }
+
+tlpAutoProbeAlarm33 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 33 had failed"
+ ::= { tlpAutoProbeAlarms 33 }
+
+tlpAutoProbeAlarm34 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 34 had failed"
+ ::= { tlpAutoProbeAlarms 34 }
+
+tlpAutoProbeAlarm35 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 35 had failed"
+ ::= { tlpAutoProbeAlarms 35 }
+
+tlpAutoProbeAlarm36 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 36 had failed"
+ ::= { tlpAutoProbeAlarms 36 }
+
+tlpAutoProbeAlarm37 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 37 had failed"
+ ::= { tlpAutoProbeAlarms 37 }
+
+tlpAutoProbeAlarm38 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 38 had failed"
+ ::= { tlpAutoProbeAlarms 38 }
+
+tlpAutoProbeAlarm39 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 39 had failed"
+ ::= { tlpAutoProbeAlarms 39 }
+
+tlpAutoProbeAlarm40 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 40 had failed"
+ ::= { tlpAutoProbeAlarms 40 }
+
+tlpAutoProbeAlarm41 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 41 had failed"
+ ::= { tlpAutoProbeAlarms 41 }
+
+tlpAutoProbeAlarm42 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 42 had failed"
+ ::= { tlpAutoProbeAlarms 42 }
+
+tlpAutoProbeAlarm43 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 43 had failed"
+ ::= { tlpAutoProbeAlarms 43 }
+
+tlpAutoProbeAlarm44 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 44 had failed"
+ ::= { tlpAutoProbeAlarms 44 }
+
+tlpAutoProbeAlarm45 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 45 had failed"
+ ::= { tlpAutoProbeAlarms 45 }
+
+tlpAutoProbeAlarm46 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 46 had failed"
+ ::= { tlpAutoProbeAlarms 46 }
+
+tlpAutoProbeAlarm47 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 47 had failed"
+ ::= { tlpAutoProbeAlarms 47 }
+
+tlpAutoProbeAlarm48 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 48 had failed"
+ ::= { tlpAutoProbeAlarms 48 }
+
+tlpAutoProbeAlarm49 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 49 had failed"
+ ::= { tlpAutoProbeAlarms 49 }
+
+tlpAutoProbeAlarm50 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 50 had failed"
+ ::= { tlpAutoProbeAlarms 50 }
+
+tlpAutoProbeAlarm51 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 51 had failed"
+ ::= { tlpAutoProbeAlarms 51 }
+
+tlpAutoProbeAlarm52 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 52 had failed"
+ ::= { tlpAutoProbeAlarms 52 }
+
+tlpAutoProbeAlarm53 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 53 had failed"
+ ::= { tlpAutoProbeAlarms 53 }
+
+tlpAutoProbeAlarm54 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 54 had failed"
+ ::= { tlpAutoProbeAlarms 54 }
+
+tlpAutoProbeAlarm55 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 55 had failed"
+ ::= { tlpAutoProbeAlarms 55 }
+
+tlpAutoProbeAlarm56 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 56 had failed"
+ ::= { tlpAutoProbeAlarms 56 }
+
+tlpAutoProbeAlarm57 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 57 had failed"
+ ::= { tlpAutoProbeAlarms 57 }
+
+tlpAutoProbeAlarm58 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 58 had failed"
+ ::= { tlpAutoProbeAlarms 58 }
+
+tlpAutoProbeAlarm59 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 59 had failed"
+ ::= { tlpAutoProbeAlarms 59 }
+
+tlpAutoProbeAlarm60 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 60 had failed"
+ ::= { tlpAutoProbeAlarms 60 }
+
+tlpAutoProbeAlarm61 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 61 had failed"
+ ::= { tlpAutoProbeAlarms 61 }
+
+tlpAutoProbeAlarm62 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 62 had failed"
+ ::= { tlpAutoProbeAlarms 62 }
+
+tlpAutoProbeAlarm63 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 63 had failed"
+ ::= { tlpAutoProbeAlarms 63 }
+
+tlpAutoProbeAlarm64 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Auto Probe 64 had failed"
+ ::= { tlpAutoProbeAlarms 64 }
+ tlpAlarmControlTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TlpAlarmControlEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of alarm conditions supported for each device managed by this
+ agent. This table contains zero, one, or many rows depending upon the
+ number of available alarms managed by each device."
+ ::= { tlpAlarmControl 1 }
+
+tlpAlarmControlEntry OBJECT-TYPE
+ SYNTAX TlpAlarmControlEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing details for a particular alarm condition."
+ INDEX { tlpDeviceIndex, tlpAlarmControlIndex }
+ ::= { tlpAlarmControlTable 1 }
+
+TlpAlarmControlEntry ::= SEQUENCE {
+ tlpAlarmControlIndex Unsigned32,
+ tlpAlarmControlDescr OBJECT IDENTIFIER,
+ tlpAlarmControlDetail DisplayString,
+ tlpAlarmControlSeverity INTEGER }
+
+tlpAlarmControlIndex OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The table row index for this alarm control entry for this device. The
+ index of any one row represents the index of the alarm entry within the
+ agent system. As such, the index values for any one device is not
+ guaranteed to start with 1 or be numerically sequential."
+ ::= { tlpAlarmControlEntry 1 }
+
+tlpAlarmControlDescr OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A reference of the alarm description object. The object referenced
+ should not be accessible, but rather be used to provide a unique
+ description for the alarm condition. The object referenced will be a
+ well known alarm object associated with the device on which the alarm
+ condition is active. This will be the same object description of an
+ alarm when in alarm as referenced by tlpAlarmDescr."
+ ::= { tlpAlarmControlEntry 2 }
+
+tlpAlarmControlDetail OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A textual description of the alarm condition. This will be the same
+ textual description of an alarm when in alarm as referenced by
+ tlpAlarmDetail."
+ ::= { tlpAlarmControlEntry 3 }
+
+tlpAlarmControlSeverity OBJECT-TYPE
+ SYNTAX INTEGER {
+ critical(1),
+ warning(2),
+ info(3) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The severity of this alarm, which can be configured as desired for
+ each alarm condition. This will be the same severity used when in alarm
+ as referenced by tlpAlarmType."
+ ::= { tlpAlarmControlEntry 4 }
+
+-- notifications
+
+tlpNotificationsAlarmEntryAdded NOTIFICATION-TYPE
+ OBJECTS { tlpAlarmId, tlpAlarmDescr, tlpAlarmTime,
+ tlpAlarmTableRef, tlpAlarmTableRowRef, tlpAlarmDetail,
+ tlpAlarmType }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent each time an alarm condition is inserted into
+ the device alarm table, tlpAlarmTable."
+ ::= { tlpNotifications 1 }
+
+tlpNotificationsAlarmEntryRemoved NOTIFICATION-TYPE
+ OBJECTS { tlpAlarmId, tlpAlarmDescr, tlpAlarmTime,
+ tlpAlarmTableRef, tlpAlarmTableRowRef, tlpAlarmDetail,
+ tlpAlarmType }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent each time an alarm condition is removed from
+ the device alarm table, tlpAlarmTable."
+ ::= { tlpNotifications 2 }
+
+tlpNotifySystemStartup NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Used to inform another entity of an agent's startup. The varbinds that follow are:
+
+ OBJ1 = tlpAgentType
+ Obj1Value = The type of engine providing this data
+ OBJ2 = tlpAgentVersion
+ Obj2Value = The current version of the engine
+ OBJ3 = tlpAgentMAC
+ Obj3Value = The MAC address of the engine
+ OBJ4 = tlpAgentSerialNum
+ Obj4Value = The serial number of the web card [should be 0 on PC]
+
+ --- if this trap is extended, place all static OIDs above this mark. all objects below
+ --- the number of devices (tlpDeviceNumDevices) is explicit as per device for enumeration by
+ --- the target receiver
+
+ OBJ5 = tlpDeviceNumDevices
+ Obj5Value = The number of devices attached
+
+ --- The following objects will be replicated per each device:
+
+ OBJ6 = The OID for an entry of tlpDeviceManufacturer, indexed by device
+ Obj6Value = The device's manufacturer
+ OBJ7 = The OID for an entry of tlpDeviceModel, indexed by device
+ Obj7Value = The device's model name
+ OBJ8 = The OID for an entry of tlpDeviceName, indexed by device
+ Obj8Value = The device's display name
+ OBJ9 = The OID for an entry of tlpDeviceLocation, indexed by device
+ Obj9Value = The device's location
+ OBJ10 = The OID for an entry of tlpDeviceRegion, indexed by device
+ Obj10Value= The device's region
+ OBJ11 = The OID for an entry of tlpDeviceProtocol, indexed by device
+ Obj11Value= The device's protocol (display string format)
+ "
+ ::= { tlpNotifications 3 }
+
+tlpNotifySystemShutdown NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Used to inform another entity of an agent's shutdown. The varbinds that follow are:
+
+ OBJ1 = tlpAgentType
+ Obj1Value = The type of engine providing this data
+ OBJ2 = tlpAgentVersion
+ Obj2Value = The current version of the engine
+ OBJ3 = tlpAgentMAC
+ Obj3Value = The MAC address of the engine
+ OBJ4 = tlpAgentSerialNum
+ Obj4Value = The serial number of the web card [should be 0 on PC]
+
+ --- if this trap is extended, place all static OIDs above this mark. all objects below
+ --- the number of devices (tlpDeviceNumDevices) is explicit as per device for enumeration by
+ --- the target receiver
+
+ OBJ5 = tlpDeviceNumDevices
+ Obj5Value = The number of devices attached
+
+ --- The following objects will be replicated per each device:
+
+ OBJ6 = The OID for an entry of tlpDeviceManufacturer, indexed by device
+ Obj6Value = The device's manufacturer
+ OBJ7 = The OID for an entry of tlpDeviceModel, indexed by device
+ Obj7Value = The device's model name
+ OBJ8 = The OID for an entry of tlpDeviceName, indexed by device
+ Obj8Value = The device's display name
+ OBJ9 = The OID for an entry of tlpDeviceLocation, indexed by device
+ Obj9Value = The device's location
+ OBJ10 = The OID for an entry of tlpDeviceRegion, indexed by device
+ Obj10Value= The device's region
+ OBJ11 = The OID for an entry of tlpDeviceProtocol, indexed by device
+ Obj11Value= The device's protocol (display string format)
+ "
+ ::= { tlpNotifications 4 }
+
+tlpNotifySystemUpdate NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Used to inform another entity of an engine's startup. The varbinds that follow are:
+
+ OBJ1 = tlpAgentType
+ Obj1Value = The type of engine providing this data
+ OBJ2 = tlpAgentVersion
+ Obj2Value = The current version of the engine
+ OBJ3 = tlpAgentMAC
+ Obj3Value = The MAC address of the engine
+ OBJ4 = tlpAgentSerialNum
+ Obj4Value = The serial number of the web card [should be 0 on PC]
+
+ --- if this trap is extended, place all static OIDs above this mark. all objects below
+ --- the number of devices (tlpDeviceNumDevices) is explicit as per device for enumeration by
+ --- the target receiver
+
+ OBJ5 = tlpDeviceNumDevices
+ Obj5Value = The number of devices attached
+
+ --- The following objects will be replicated per each device:
+
+ OBJ6 = The OID for an entry of tlpDeviceManufacturer, indexed by device
+ Obj6Value = The device's manufacturer
+ OBJ7 = The OID for an entry of tlpDeviceModel, indexed by device
+ Obj7Value = The device's model name
+ OBJ8 = The OID for an entry of tlpDeviceName, indexed by device
+ Obj8Value = The device's display name
+ OBJ9 = The OID for an entry of tlpDeviceLocation, indexed by device
+ Obj9Value = The device's location
+ OBJ10 = The OID for an entry of tlpDeviceRegion, indexed by device
+ Obj10Value= The device's region
+ OBJ11 = The OID for an entry of tlpDeviceProtocol, indexed by device
+ Obj11Value= The device's protocol (display string format)
+ "
+ ::= { tlpNotifications 5 }
+
+tlpNotifyTest NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Used when performing a test of the system or an alert notification contact. The varbinds
+ that follow are:
+
+ OBJ1 = tlpAgentType
+ Obj1Value = The type of engine providing this data
+ OBJ2 = tlpAgentVersion
+ Obj2Value = The current version of the engine
+ OBJ3 = tlpAgentMAC
+ Obj3Value = The MAC address of the engine
+ OBJ4 = tlpAgentSerialNum
+ Obj4Value = The serial number of the web card [should be 0 on PC]
+ "
+ ::= { tlpNotifications 6 }
+
+tlpNotificationsAgent OBJECT IDENTIFIER ::= { tlpNotificationsEvent 1 }
+
+tlpNotificationsDevice OBJECT IDENTIFIER ::= { tlpNotificationsEvent 2 }
+
+tlpNotificationsDeviceInternalFirmwareFault NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, tlpNotifyEventTableRef, tlpNotifyEventTableRowRef }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the device experiences an internal
+ firmware failure."
+ ::= { tlpNotificationsDevice 1 }
+
+tlpNotificationsDeviceInternalHardwareFault NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, tlpNotifyEventTableRef, tlpNotifyEventTableRowRef }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the device experiences an internal
+ hardware failure."
+ ::= { tlpNotificationsDevice 2 }
+
+tlpNotificationsDeviceConfigurationChange NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, tlpNotifyEventTableRef, tlpNotifyEventTableRowRef }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the device configuration changes."
+ ::= { tlpNotificationsDevice 3 }
+
+tlpNotificationsDeviceFirmwareUpdate NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, tlpNotifyEventTableRef, tlpNotifyEventTableRowRef }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the device firmware is updated."
+ ::= { tlpNotificationsDevice 4 }
+
+tlpNotificationsDeviceMicrocontrollerReset NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, tlpNotifyEventTableRef, tlpNotifyEventTableRowRef }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the device microcontroller resets."
+ ::= { tlpNotificationsDevice 5 }
+
+tlpNotificationsDeviceSystemInformation NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, tlpNotifyEventTableRef, tlpNotifyEventTableRowRef }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the device sysytem information changes."
+ ::= { tlpNotificationsDevice 6 }
+
+tlpNotificationsDeviceNvrChecksumMismatch NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, tlpNotifyEventTableRef, tlpNotifyEventTableRowRef }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the NVR is corrupted."
+ ::= { tlpNotificationsDevice 7 }
+
+tlpNotificationsDeviceUsbCommunicationsEstablished NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, tlpNotifyEventTableRef, tlpNotifyEventTableRowRef }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the device USB communications is established."
+ ::= { tlpNotificationsDevice 8 }
+
+tlpNotificationsDeviceUsbCommunicationsLost NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, tlpNotifyEventTableRef, tlpNotifyEventTableRowRef }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the device USB communications is lost."
+ ::= { tlpNotificationsDevice 9 }
+
+tlpNotificationsDevicePowerSupplyShutdown NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, tlpNotifyEventTableRef, tlpNotifyEventTableRowRef }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the device reports a shutdown occurred due to a power supply fault."
+ ::= { tlpNotificationsDevice 10 }
+
+tlpNotificationsDeviceOverLoadShutdown NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, tlpNotifyEventTableRef, tlpNotifyEventTableRowRef }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the device reports a shutdown occurred due to an over load fault."
+ ::= { tlpNotificationsDevice 11 }
+
+tlpNotificationsDeviceCurrentLimitShutdown NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, tlpNotifyEventTableRef, tlpNotifyEventTableRowRef }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the device reports a shutdown occurred due to a current limit fault."
+ ::= { tlpNotificationsDevice 12 }
+
+tlpNotificationsDeviceOverTemperatureShutdown NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, tlpNotifyEventTableRef, tlpNotifyEventTableRowRef }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the device reports a shutdown occurred due to an over temperature fault."
+ ::= { tlpNotificationsDevice 13 }
+
+tlpNotificationsDeviceModeTransitionTimeout NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, tlpNotifyEventTableRef, tlpNotifyEventTableRowRef }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the device timed out transitioning to a mode."
+ ::= { tlpNotificationsDevice 14 }
+
+tlpNotificationsDeviceFailedModeTransitionToIdle NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, tlpNotifyEventTableRef, tlpNotifyEventTableRowRef }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the device failed a transition to idle mode."
+ ::= { tlpNotificationsDevice 15 }
+
+tlpNotificationsDeviceInternalCommunicationsLost NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, tlpNotifyEventTableRef, tlpNotifyEventTableRowRef }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the device lost internal communications."
+ ::= { tlpNotificationsDevice 16 }
+
+tlpNotificationsDeviceAcknowledgeFaults NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, tlpNotifyEventTableRef, tlpNotifyEventTableRowRef }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when device faults are acknowledged."
+ ::= { tlpNotificationsDevice 17 }
+
+tlpNotificationsDeviceTransferToReboot NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, tlpNotifyEventTableRef, tlpNotifyEventTableRowRef }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when a device reboot occurred."
+ ::= { tlpNotificationsDevice 18 }
+
+tlpNotificationsDeviceTransferToWatchdogReboot NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, tlpNotifyEventTableRef, tlpNotifyEventTableRowRef }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when a device reboot occurred due to a watchdog fault."
+ ::= { tlpNotificationsDevice 19 }
+
+tlpNotificationsDeviceTransferToLatchedIdle NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, tlpNotifyEventTableRef, tlpNotifyEventTableRowRef }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the device transferred to latched idle mode."
+ ::= { tlpNotificationsDevice 20 }
+
+tlpNotificationsDeviceTransferToLatchedStandby NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, tlpNotifyEventTableRef, tlpNotifyEventTableRowRef }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the device transferred to latched standby mode."
+ ::= {tlpNotificationsDevice 21 }
+
+tlpNotificationsDeviceTransferToLatchedLine NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, tlpNotifyEventTableRef, tlpNotifyEventTableRowRef }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the device transferred to latched line mode."
+ ::= { tlpNotificationsDevice 22 }
+
+tlpNotificationsDeviceFailSafeClockMonitorEngaged NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, tlpNotifyEventTableRef, tlpNotifyEventTableRowRef }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the fail safe clock monitor is engaged."
+ ::= { tlpNotificationsDevice 23 }
+
+tlpNotificationsDeviceTransferToIdle NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, tlpNotifyEventTableRef, tlpNotifyEventTableRowRef }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the device transferred to idle mode."
+ ::= { tlpNotificationsDevice 24 }
+
+tlpNotificationsDeviceVoutUnderVoltageShutdown NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, tlpNotifyEventTableRef, tlpNotifyEventTableRowRef }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the device reports a shutdown occurred due to a vout under voltage fault."
+ ::= { tlpNotificationsDevice 25 }
+
+tlpNotificationsDeviceVoutOverVoltageShutdown NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, tlpNotifyEventTableRef, tlpNotifyEventTableRowRef }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the device reports a shutdown occurred due to a vout over voltage fault."
+ ::= { tlpNotificationsDevice 26 }
+
+tlpNotificationsDeviceUnhandledFault NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, tlpNotifyEventTableRef, tlpNotifyEventTableRowRef }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the device reports an unhandled fault."
+ ::= { tlpNotificationsDevice 27 }
+
+tlpNotificationsUps OBJECT IDENTIFIER ::= { tlpNotificationsEvent 3 }
+
+tlpNotificationsUpsBatteryLowVoltageShutdown NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, tlpNotifyEventTableRef, tlpNotifyEventTableRowRef }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the ups reports a shutdown occurred due to a low battery voltage fault."
+ ::= { tlpNotificationsUps 1 }
+
+tlpNotificationsUpsBatteryLowPercentageShutdown NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, tlpNotifyEventTableRef, tlpNotifyEventTableRowRef }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the ups reports a shutdown occurred due to a low battery percentage fault."
+ ::= { tlpNotificationsUps 2 }
+
+tlpNotificationsUpsBatteryOverVoltageShutdown NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, tlpNotifyEventTableRef, tlpNotifyEventTableRowRef }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the ups reports a shutdown occurred due to a battery over voltage fault."
+ ::= { tlpNotificationsUps 3 }
+
+tlpNotificationsUpsBatteryOverCurrentShutdown NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, tlpNotifyEventTableRef, tlpNotifyEventTableRowRef }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the ups reports a shutdown occurred due to a battery over current fault."
+ ::= { tlpNotificationsUps 4 }
+
+tlpNotificationsUpsBatteryUnknownTypeShutdown NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, tlpNotifyEventTableRef, tlpNotifyEventTableRowRef }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the ups reports a shutdown occurred due to an unknown battery type fault."
+ ::= { tlpNotificationsUps 5 }
+
+tlpNotificationsUpsBatteryConfigurationMismatch NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, tlpNotifyEventTableRef, tlpNotifyEventTableRowRef }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the ups battery configuration is mismatched."
+ ::= { tlpNotificationsUps 6 }
+
+tlpNotificationsUpsBatteryUnderVoltageShutdown NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, tlpNotifyEventTableRef, tlpNotifyEventTableRowRef }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the ups reports a shutdown occurred due to a battery under voltage fault."
+ ::= { tlpNotificationsUps 7 }
+
+tlpNotificationsUpsSlaBatteryOverTemperatureShutdown NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, tlpNotifyEventTableRef, tlpNotifyEventTableRowRef }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the ups reports a shutdown occurred due to an SLA battery over temperature fault."
+ ::= { tlpNotificationsUps 8 }
+
+tlpNotificationsUpsBatteryInstallation NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, tlpNotifyEventTableRef, tlpNotifyEventTableRowRef }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when a battery installation occurs."
+ ::= { tlpNotificationsUps 9 }
+
+tlpNotificationsUpsChargerBulkToAcceptance NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, tlpNotifyEventTableRef, tlpNotifyEventTableRowRef }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when ups battery charging."
+ ::= { tlpNotificationsUps 10 }
+
+tlpNotificationsUpsChargerAcceptanceToFloat NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, tlpNotifyEventTableRef, tlpNotifyEventTableRowRef }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when ups battery fully charged."
+ ::= { tlpNotificationsUps 11 }
+
+tlpNotificationsUpsChargerFloatToBulk NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, tlpNotifyEventTableRef, tlpNotifyEventTableRowRef }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when ups battery not fully charged."
+ ::= { tlpNotificationsUps 12 }
+
+tlpNotificationsUpsTransferToSelftest NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, tlpNotifyEventTableRef, tlpNotifyEventTableRowRef }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when a self test is initiated."
+ ::= { tlpNotificationsUps 13 }
+
+tlpNotificationsUpsTransferToEconomy NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, tlpNotifyEventTableRef, tlpNotifyEventTableRowRef }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the device transferred to economy mode."
+ ::= { tlpNotificationsUps 14 }
+
+tlpNotificationsUpsLineConnectRelayFaultShutdown NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, tlpNotifyEventTableRef, tlpNotifyEventTableRowRef }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the device reports a shutdown occurred due to line connect relay fault."
+ ::= { tlpNotificationsUps 15 }
+
+tlpNotificationsUpsTransferToFaultBypass NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, tlpNotifyEventTableRef, tlpNotifyEventTableRowRef }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the device transferred to fault bypass mode."
+ ::= { tlpNotificationsUps 16 }
+
+tlpNotificationsUpsBypassPowerDistributionModuleDisconnected NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, tlpNotifyEventTableRef, tlpNotifyEventTableRowRef }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when bypass power distribution module is disconnected."
+ ::= { tlpNotificationsUps 17 }
+
+tlpNotificationsUpsManualBypassActivatedFromUnsupportedMode NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, tlpNotifyEventTableRef, tlpNotifyEventTableRowRef }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when manual bypass activated from an unsupported UPS mode."
+ ::= { tlpNotificationsUps 18 }
+
+tlpNotificationsUpsOnBatteryTimeoutShutdown NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, tlpNotifyEventTableRef, tlpNotifyEventTableRowRef }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the device reports a shutdown occurred due to on battery timeout."
+ ::= { tlpNotificationsUps 19 }
+
+tlpNotificationsUpsLowBatteryPercentageShutdown NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, tlpNotifyEventTableRef, tlpNotifyEventTableRowRef }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the device reports a shutdown occurred due to low battery percentage."
+ ::= { tlpNotificationsUps 20 }
+
+tlpNotificationsPdu OBJECT IDENTIFIER ::= { tlpNotificationsEvent 4 }
+
+tlpNotificationsEnvirosense OBJECT IDENTIFIER ::= { tlpNotificationsEvent 5 }
+
+tlpNotificationsAts OBJECT IDENTIFIER ::= { tlpNotificationsEvent 6 }
+
+tlpNotificationsAtsSource1NotAvailable NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, tlpNotifyEventTableRef, tlpNotifyEventTableRowRef }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when input on source one is not available.
+ For atss with the designation of primary and secondary, this
+ notification denotes input on the primary source is not available."
+ ::= { tlpNotificationsAts 1 }
+
+tlpNotificationsAtsSource2NotAvailable NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, tlpNotifyEventTableRef, tlpNotifyEventTableRowRef }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when input on source two is not available.
+ For atss with the designation of primary and secondary, this
+ notification denotes input on the secondary source is not available."
+ ::= { tlpNotificationsAts 2 }
+
+tlpNotificationsAtsLockdownToSource1 NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, tlpNotifyEventTableRef, tlpNotifyEventTableRowRef }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent upon a transfer circuit fault causing the
+ device to be locked on source 1."
+ ::= { tlpNotificationsAts 3 }
+
+tlpNotificationsAtsLockdownToSource2 NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, tlpNotifyEventTableRef, tlpNotifyEventTableRowRef }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent upon a transfer circuit fault causing the
+ device to be locked on source 2."
+ ::= { tlpNotificationsAts 4 }
+
+tlpNotificationsAtsSource1Available NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, tlpNotifyEventTableRef, tlpNotifyEventTableRowRef }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when source 1 is available and ready for
+ use."
+ ::= { tlpNotificationsAts 5 }
+
+tlpNotificationsAtsSource2Available NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, tlpNotifyEventTableRef, tlpNotifyEventTableRowRef }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when source 2 is available and ready for
+ use."
+ ::= { tlpNotificationsAts 6 }
+
+tlpNotificationsAtsSource1Brownout NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, tlpNotifyEventTableRef, tlpNotifyEventTableRowRef }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when a brownout condition occurred on source 1."
+ ::= { tlpNotificationsAts 7 }
+
+tlpNotificationsAtsSource2Brownout NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, tlpNotifyEventTableRef, tlpNotifyEventTableRowRef }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when a brownout condition occurred on source 2."
+ ::= { tlpNotificationsAts 8 }
+
+tlpNotificationsAtsSource1VoltageDrop NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, tlpNotifyEventTableRef, tlpNotifyEventTableRowRef }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the voltage on source 1 drops below a
+ usable state."
+ ::= { tlpNotificationsAts 9 }
+
+tlpNotificationsAtsSource2VoltageDrop NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, tlpNotifyEventTableRef, tlpNotifyEventTableRowRef }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the voltage on source 2 drops below a
+ usable state."
+ ::= { tlpNotificationsAts 10 }
+
+tlpNotificationsAtsTimedReturnToSource1 NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, tlpNotifyEventTableRef, tlpNotifyEventTableRowRef }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the active input source returns to
+ source 1 from source 2 after a delay time expires."
+ ::= { tlpNotificationsAts 11 }
+
+tlpNotificationsAtsTimedReturnToSource2 NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, tlpNotifyEventTableRef, tlpNotifyEventTableRowRef }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the active input source returns to
+ source 2 from source 1 after a delay time expires."
+ ::= { tlpNotificationsAts 12 }
+
+tlpNotificationsAtsTransferToSource1 NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, tlpNotifyEventTableRef, tlpNotifyEventTableRowRef }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the active input source transfers
+ from source 2 to source 1."
+ ::= { tlpNotificationsAts 13 }
+
+tlpNotificationsAtsTransferToSource2 NOTIFICATION-TYPE
+ OBJECTS { sysUpTime, tlpNotifyEventTableRef, tlpNotifyEventTableRowRef }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the active input source transfers
+ from source 1 to source 2."
+ ::= { tlpNotificationsAts 14 }
+
+tlpNotificationsCooling OBJECT IDENTIFIER ::= { tlpNotificationsEvent 7 }
+
+tlpNotificationsKvm OBJECT IDENTIFIER ::= { tlpNotificationsEvent 8 }
+
+tlpNotificationsRackTrack OBJECT IDENTIFIER ::= { tlpNotificationsEvent 9 }
+
+tlpNotificationsSwitch OBJECT IDENTIFIER ::= { tlpNotificationsEvent 10 }
+
+tlpNotifyEventTableRef OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This value references the OID of a table object applicable to the event
+ condition. This, in conjunction with the table row as defined by
+ tlpAlarmTableRowRef, specifies the object/row within this table to which
+ the event condition applies. Refer to tlpAlarmTableRef for more information."
+ ::= { tlpNotificationsEventParameters 1 }
+
+tlpNotifyEventTableRowRef OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This value is used in conjunction with tlpNotifyEventTableRef to define the
+ object associated with this event condition. See the description of
+ tlpNotifyEventTableRef for more information."
+ ::= { tlpNotificationsEventParameters 2 }
+
+END