diff options
Diffstat (limited to 'MIBS/ibm/IBM-3200-MIB')
| -rw-r--r-- | MIBS/ibm/IBM-3200-MIB | 939 |
1 files changed, 939 insertions, 0 deletions
diff --git a/MIBS/ibm/IBM-3200-MIB b/MIBS/ibm/IBM-3200-MIB new file mode 100644 index 0000000..699bdf1 --- /dev/null +++ b/MIBS/ibm/IBM-3200-MIB @@ -0,0 +1,939 @@ +
+--
+-- IBM-3200-MIB.mib
+--
+
+--
+-- Version 1.0 - 24-Jan-2006
+-- Initial release
+--
+-- Version 1.1 - 02-Feb-2006
+-- Re-definedibm3200 root OID;
+-- Added comments in notifications to add directives for trap classification
+--
+-- Version 1.2 - 14-March-2007
+-- library fault OIDs added
+--
+-- Version 1.3 - 14-Dec-2007
+-- Change the ibm3200MIB OBJECT IDENTIFIER from "{ ibm3200 1 }" to "{ ibm3200 0 }";
+--
+-- Version 1.4 - 14-Jan-2008
+-- changes done for SNMPv2 implementation:
+-- Added SNMPv1 trap definitions to MIB to decode v1 traps correct
+--
+-- Version 1.5 - 29-April-2009
+-- trap eventLoaderPasswordChange for Library password change added
+--
+-- Version 1.6 - 16-September-2009
+-- trap eventEncryptionConfigChange for Library password change added
+--
+-- Version 1.7 - 25-March-2010
+-- trap eventLoaderConfigChange added
+-- trap eventBrowserLogin added
+-- trap eventBrowserLogout added
+--
+
+ IBM-3200-MIB DEFINITIONS ::= BEGIN
+
+ IMPORTS
+ OBJECT-TYPE
+ FROM RFC-1212
+ TRAP-TYPE
+ FROM RFC-1215
+ enterprises
+ FROM RFC1155-SMI
+ DisplayString
+ FROM RFC1213-MIB;
+
+--
+-- Node definitions
+--
+
+ ibm OBJECT IDENTIFIER
+ ::= { enterprises 2 }
+
+ ibmProd OBJECT IDENTIFIER
+ ::= { ibm 6 }
+
+ ibm3200 OBJECT IDENTIFIER
+ ::= { ibmProd 211 }
+
+ ibm3200MIB OBJECT IDENTIFIER
+ ::= { ibm3200 0 }
+
+ ibm3200MIBTraps OBJECT IDENTIFIER
+ ::= { ibm3200MIB 0 }
+
+ ibm3200MIBAdmin OBJECT IDENTIFIER
+ ::= { ibm3200MIB 1 }
+
+ ibm3200MIBObjects OBJECT IDENTIFIER
+ ::= { ibm3200MIB 2 }
+
+ ibm3200MIBConformance OBJECT IDENTIFIER
+ ::= { ibm3200MIB 3 }
+
+---
+--- Product ID Group
+---
+ ibm3200Id OBJECT IDENTIFIER ::= {ibm3200 1 }
+
+ ibm3200IdDisplayName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Name of this product for display purposes."
+ ::= {ibm3200Id 1 }
+
+ ibm3200IdDescription OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A short description of this product such as <LTO Tape Library>."
+ ::= {ibm3200Id 2 }
+
+ ibm3200AgentVendor OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the product manufacturer."
+ ::= {ibm3200Id 3 }
+
+ ibm3200IdAgentVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The version of this product."
+ ::= {ibm3200Id 4 }
+
+ ibm3200IdBuildNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The software build number of the product."
+ ::= {ibm3200Id 5 }
+
+ ibm3200IdURL OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The URL of the web-based application to manage this product."
+ ::= {ibm3200Id 6 }
+
+---
+--- Product Status Group
+---
+ ibm3200Status OBJECT IDENTIFIER ::= {ibm3200 2 }
+
+ ibm3200StatusGlobalStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ other(1),
+ unknown(2),
+ ok(3),
+ non-critical(4),
+ critical(5),
+ non-Recoverable(6)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Current status of the product.
+ This is a rollup for the entire agent including any
+ monitored devices. The status is intended to give
+ initiative to a snmp monitor to get further data when
+ this status is abnormal."
+ ::= {ibm3200Status 1 }
+
+ ibm3200StatusLastGlobalStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ other(1),
+ unknown(2),
+ ok(3),
+ non-critical(4),
+ critical(5),
+ non-recoverable(6)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The status before the current status which induced an initiative
+ to issue a global status change trap."
+ ::= {ibm3200Status 2 }
+
+ ibm3200StatusTimeStamp OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The last time that the agent values have been updated.
+ The time shoule be in a relative timestamp, such as SysUpTime."
+ ::= {ibm3200Status 3 }
+
+ ibm3200StatusGetTimeOut OBJECT-TYPE
+ SYNTAX INTEGER (1..10000)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Suggested time out value in milleseconds for how long the SNMP getter
+ should wait while attempting to poll the product SNMP service."
+ ::= {ibm3200Status 4 }
+
+ ibm3200StatusRefreshRate OBJECT-TYPE
+ SYNTAX INTEGER (-1..1000000000)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Rate in seconds at which the agent cached data is being updated. If the
+ value is 0 then the data is not cached. If the value is -1 then the value does
+ not apply."
+ ::= {ibm3200Status 5 }
+
+ ibm3200StatusGeneratingTrapFlag OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ true(1),
+ false(2),
+ disabled(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates id this SNMP agent is capable of and/or is generating SNMP traps."
+ ::= {ibm3200Status 6 }
+
+---
+--- Physical Group
+---
+ ibm3200Physical OBJECT IDENTIFIER ::= {ibm3200 3 }
+
+ libraryTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF LibraryEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A table of library status."
+ ::= {ibm3200Physical 1 }
+
+ libraryEntry OBJECT-TYPE
+ SYNTAX LibraryEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Entry in the library Table. Each entry contains
+ an index (libraryEntryId), and the values associated
+ with the device."
+ INDEX { libraryEntryId }
+ ::= { libraryTable 1 }
+
+ LibraryEntry ::=
+ SEQUENCE {
+ libraryEntryId
+ INTEGER,
+ libraryState
+ INTEGER,
+ libraryTimeStamp
+ INTEGER,
+ libraryType
+ INTEGER,
+ libraryScsiId
+ INTEGER,
+ libraryScsiLun
+ INTEGER,
+ libraryVendorId
+ DisplayString,
+ libraryProductId
+ DisplayString,
+ libraryFwLevel
+ DisplayString,
+ librarySerNum
+ DisplayString,
+ libraryDrvCnt
+ INTEGER,
+ librarySlotCnt
+ INTEGER,
+ libraryImpExpCnt
+ INTEGER,
+ libraryTranspCnt
+ INTEGER,
+ libraryMoves
+ INTEGER,
+ librarySlotFetchRetries
+ INTEGER,
+ librarySlotStowRetries
+ INTEGER,
+ libraryDrvFetchRetries
+ INTEGER,
+ libraryDrvStowRetries
+ INTEGER,
+ libraryDoorState
+ INTEGER,
+ libraryImpExpState
+ INTEGER,
+ libraryFaultFSC
+ INTEGER,
+ libraryFaultSev
+ INTEGER,
+ libraryFaultDescr
+ DisplayString
+ }
+
+ libraryEntryId OBJECT-TYPE
+ SYNTAX INTEGER (1..256)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Table entry index value. Each unique physical device has a unique libraryEntryId."
+ ::= { libraryEntry 1 }
+
+ libraryState OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Device state."
+ ::= { libraryEntry 2 }
+
+ libraryTimeStamp OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Relative time in sec from power-up."
+ ::= { libraryEntry 3 }
+
+ libraryType OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Device type."
+ ::= { libraryEntry 4 }
+
+ libraryScsiId OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "SCSI ID of the device."
+ ::= { libraryEntry 5}
+
+ libraryScsiLun OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "SCSI Lun of the device."
+ ::= { libraryEntry 6 }
+
+ libraryVendorId OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Library Vendor ID string as reported in a SCSI Inquiry command."
+ ::= { libraryEntry 7 }
+
+ libraryProductId OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Library Product Id string as reported in a SCSI Inquiry command."
+ ::= { libraryEntry 8 }
+
+ libraryFwLevel OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Library Firmware level as reported in a SCSI Inquiry command."
+ ::= { libraryEntry 9 }
+
+ librarySerNum OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Library serial number as reported in SCSI Inquiry command, page 0x80."
+ ::= { libraryEntry 10 }
+
+ libraryDrvCnt OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Number of drives contained in this library."
+ ::= { libraryEntry 11 }
+
+ librarySlotCnt OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Number of cartridge slots contained in this library"
+ ::= { libraryEntry 12 }
+
+ libraryImpExpCnt OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Number of import/export elements (mail slots) contained in this library"
+ ::= { libraryEntry 13 }
+
+ libraryTranspCnt OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Number of transport elements (robots) contained in this library."
+ ::= { libraryEntry 14 }
+
+ libraryMoves OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Total number of move operations done by this library."
+ ::= { libraryEntry 15 }
+
+ librarySlotFetchRetries OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "Total number of slot fetch retries by this library."
+ ::= { libraryEntry 16 }
+
+ librarySlotStowRetries OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "Total number of slot stow retries by this library."
+ ::= { libraryEntry 17 }
+
+ libraryDrvFetchRetries OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "Total number of drive fetch retries by this library."
+ ::= { libraryEntry 18 }
+
+ libraryDrvStowRetries OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "Total number of drive stow retries by this library."
+ ::= { libraryEntry 19 }
+
+ libraryDoorState OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ unknown(1),
+ open(2),
+ closed(3),
+ locked(4)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "State of the door(s) pf this library. The interpretation of this value is vendor specific."
+ ::= { libraryEntry 20 }
+
+ libraryImpExpState OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ unknown(1),
+ open(2),
+ closed(3),
+ locked(4)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "State of the Import/Export element(s) of this library. The interpretation of this value is vendor specific."
+ ::= { libraryEntry 21 }
+
+ libraryFaultFSC OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "The library Fault error code."
+ ::= { libraryEntry 22 }
+
+ libraryFaultSev OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ informational(1),
+ minor(2),
+ major(3),
+ critical(4)
+ }
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "The library Fault severity."
+ ::= { libraryEntry 23 }
+
+ libraryFaultDescr OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS optional
+ DESCRIPTION
+ "The library Fault description."
+ ::= { libraryEntry 24 }
+
+ driveTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF DriveEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A table of all tape drive devices in this library."
+ ::= {ibm3200Physical 2 }
+
+ driveEntry OBJECT-TYPE
+ SYNTAX DriveEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Entry in the device Table. Each entry contains
+ an index (driveEntryId), and the values associated
+ with the device."
+ INDEX { driveEntryId }
+ ::= { driveTable 1 }
+
+ DriveEntry ::=
+ SEQUENCE {
+ driveEntryId
+ INTEGER,
+ driveState
+ INTEGER,
+ driveTimeStamp
+ INTEGER,
+ driveType
+ INTEGER,
+ driveScsiId
+ INTEGER,
+ driveScsiLun
+ INTEGER,
+ driveVendorId
+ DisplayString,
+ driveProductId
+ DisplayString,
+ driveFwlevel
+ DisplayString,
+ driveSerNum
+ DisplayString,
+ driveLibrarySN
+ DisplayString,
+ driveTpHrs
+ INTEGER,
+ driveClean
+ INTEGER,
+ driveLoads
+ INTEGER,
+ driveSoftWrtErrors
+ INTEGER,
+ driveHardWrtErrors
+ INTEGER,
+ driveSoftReadErrors
+ INTEGER,
+ driveHardReadErrors
+ INTEGER
+ }
+
+ driveEntryId OBJECT-TYPE
+ SYNTAX INTEGER (1..512)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Table entry index value. Each unique physical device has a unique driveEntryId."
+ ::= { driveEntry 1 }
+
+ driveState OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Device SCSI State."
+ ::= { driveEntry 2 }
+
+ driveTimeStamp OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Universal time in sec since UTC 1/1/70 when the device data was last updated."
+ ::= { driveEntry 3 }
+
+ driveType OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "SCSI device type."
+ ::= { driveEntry 4 }
+
+ driveScsiId OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "SCSI ID of the device."
+ ::= { driveEntry 5 }
+
+ driveScsiLun OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "SCSI Lun of the device."
+ ::= { driveEntry 6 }
+
+ driveVendorId OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Device Vendor as would be reported in a SCSI Inquiry command."
+ ::= { driveEntry 7 }
+
+ driveProductId OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Device Model as would be reported in a SCSI Inquiry command."
+ ::= { driveEntry 8 }
+
+ driveFwlevel OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Device firmware level as would be reported in a SCSI Inquiry command."
+ ::= { driveEntry 9 }
+
+ driveSerNum OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Device serial number as reported in SCSI Inquiry command, page 0x80."
+ ::= { driveEntry 10 }
+
+ driveLibrarySN OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Serial Number of the library that this drive is in as reported in SCSI Inquiry command, page 0x80, for the media mover device."
+ ::= { driveEntry 11 }
+
+ driveTpHrs OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Total drive motion hours of this device."
+ ::= { driveEntry 12 }
+
+ driveClean OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Cleaning State of the device. The interpretation of this value is vendor specific."
+ ::= { driveEntry 13 }
+
+ driveLoads OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Total cartridge loads for the drive."
+ ::= { driveEntry 14 }
+
+ driveSoftWrtErrors OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Recovered soft write error count for current cartridge"
+ ::= { driveEntry 15 }
+
+ driveHardWrtErrors OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Hard write error count for current cartridge"
+ ::= { driveEntry 16 }
+
+ driveSoftReadErrors OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Recovered soft read error count for current cartridge"
+ ::= { driveEntry 17 }
+
+ driveHardReadErrors OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Hard read error count for current cartridge"
+ ::= { driveEntry 18 }
+
+--
+-- Trap definitions
+--
+ ibm3200Event OBJECT IDENTIFIER ::= {ibm3200 4 }
+
+ eventStatusChange NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "The library status has changed."
+ --#TYPE "Library Status Change"
+ --#SUMMARY "The library %s (Serial Number %s) status has changed from %s to %s"
+ --#ARGUMENTS {0,1,2,3}
+ --#SEVERITY INFORMATIONAL
+ ::= {ibm3200Event 1}
+
+ eventDoorOpen NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "The library door has been opened."
+ --#TYPE "Library Door Opened"
+ --#SUMMARY "The library %s (Serial Number %s) door has been opened."
+ --#ARGUMENTS {0,1}
+ --#SEVERITY INFORMATIONAL
+ ::= {ibm3200Event 2}
+
+ eventMailSlotAccessed NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "The library mail slot has been accessed."
+ --#TYPE "Library Mail Slot Accessed"
+ --#SUMMARY "The library %s (Serial Number %s) mail slot has been accessed."
+ --#ARGUMENTS {0,1}
+ --#SEVERITY INFORMATIONAL
+ ::= {ibm3200Event 3}
+
+ eventFaultPosted NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "The library has posted a hard fault."
+ --#TYPE "Library Hard Fault Posted"
+ --#SUMMARY "The library %s (Serial Number %s) has posted a hard fault. Severity = %s, FSC = %s, Description = %s."
+ --#ARGUMENTS {0,1,2,3,4}
+ --#SEVERITY CRITICAL
+ ::= {ibm3200Event 4}
+
+ eventRequestDriveClean NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "One of the library tape drives has requested a cleaning cycle to ensure continued
+ data reliability."
+ --#TYPE "Tape Drive Requested Cleaning"
+ --#SUMMARY "One of the library %s (Serial Number %s) tape drives has requested a cleaning cycle."
+ --#ARGUMENTS {0,1}
+ --#SEVERITY INFORMATIONAL
+ ::= {ibm3200Event 5}
+
+ eventDriveError NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "One of the library tape drives has reported an error condition."
+ --#TYPE "Tape Drive Reported Error"
+ --#SUMMARY "One of the library %s (Serial Number %s) tape drives has reported an error condition."
+ --#ARGUMENTS {0,1}
+ --#SEVERITY MAJOR
+ ::= {ibm3200Event 6}
+
+ eventLoaderRetriesExcessive NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "The library has detected excessive loader retries."
+ --#TYPE "Excessive loader retries"
+ --#SUMMARY "The library %s (Serial Number %s) has detected excessive loader retries."
+ --#ARGUMENTS {0,1}
+ --#SEVERITY MINOR
+ ::= {ibm3200Event 7}
+
+ eventLoaderOK NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "The library has reverted to normal operation."
+ --#TYPE "Library reverted to normal operation"
+ --#SUMMARY "The library %s (Serial Number %s) has reverted to normal operation."
+ --#ARGUMENTS {0,1}
+ --#SEVERITY INFORMATIONAL
+ ::= {ibm3200Event 8}
+
+ eventLoaderPasswordChange NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Library password has changed"
+ --#TYPE "Password Change"
+ --#SUMMARY "An account password in library %s (Serial Number %s) has changed."
+ --#ARGUMENTS {0,1}
+ --#SEVERITY INFORMATIONAL
+ ::= {ibm3200Event 9}
+
+ eventLoaderConfigChange NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "A logical library configuration has been changed."
+ --#TYPE "Configuration Change"
+ --#SUMMARY "A logical library configuration has been changed."
+ --#ARGUMENTS {0,1}
+ --#SEVERITY INFORMATIONAL
+ ::= {ibm3200Event 10}
+
+ eventBrowserLogin NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Someone logged in via Web Browser."
+ --#TYPE "Web Access"
+ --#SUMMARY "Someone logged in via Web Browser."
+ --#ARGUMENTS {0,1}
+ --#SEVERITY INFORMATIONAL
+ ::= {ibm3200Event 11}
+
+ eventBrowserLogout NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Someone logged from Web Browser."
+ --#TYPE "Web Access"
+ --#SUMMARY "Someone logged from Web Browser."
+ --#ARGUMENTS {0,1}
+ --#SEVERITY INFORMATIONAL
+ ::= {ibm3200Event 12}
+
+
+ --OLD Style Trap definitions
+
+ eventStatusChange TRAP-TYPE
+ ENTERPRISE ibm3200Event
+ VARIABLES { libraryProductId,
+ librarySerNum,
+ ibm3200StatusLastGlobalStatus,
+ ibm3200StatusGlobalStatus }
+ DESCRIPTION
+ "The library status has changed."
+ ::= 1
+
+ eventDoorOpen TRAP-TYPE
+ ENTERPRISE ibm3200Event
+ VARIABLES { libraryProductId,
+ librarySerNum }
+ DESCRIPTION
+ "The library door has been opened."
+ ::= 2
+
+ eventMailSlotAccessed TRAP-TYPE
+ ENTERPRISE ibm3200Event
+ VARIABLES { libraryProductId,
+ librarySerNum }
+ DESCRIPTION
+ "The library mail slot has been accessed."
+ ::= 3
+
+ eventFaultPosted TRAP-TYPE
+ ENTERPRISE ibm3200Event
+ VARIABLES { libraryProductId,
+ librarySerNum,
+ libraryFaultSev,
+ libraryFaultFSC,
+ libraryFaultDescr }
+ DESCRIPTION
+ "The library has posted a hard fault."
+ ::= 4
+
+ eventRequestDriveClean TRAP-TYPE
+ ENTERPRISE ibm3200Event
+ VARIABLES { libraryProductId,
+ librarySerNum }
+ DESCRIPTION
+ "One of the library tape drives has requested a cleaning cycle to ensure continued
+ data reliability."
+ ::= 5
+
+ eventDriveError TRAP-TYPE
+ ENTERPRISE ibm3200Event
+ VARIABLES { libraryProductId,
+ librarySerNum }
+ DESCRIPTION
+ "One of the library tape drives has reported an error condition."
+ ::= 6
+
+ eventLoaderRetriesExcessive TRAP-TYPE
+ ENTERPRISE ibm3200Event
+ VARIABLES { libraryProductId,
+ librarySerNum }
+ DESCRIPTION
+ "The library has detected excessive loader retries."
+ ::= 7
+
+ eventLoaderOK TRAP-TYPE
+ ENTERPRISE ibm3200Event
+ VARIABLES { libraryProductId,
+ librarySerNum }
+ DESCRIPTION
+ "The library has reverted to normal operation."
+ ::= 8
+
+ eventLoaderPasswordChange TRAP-TYPE
+ ENTERPRISE ibm3200Event
+ VARIABLES { libraryProductId,
+ librarySerNum }
+ DESCRIPTION
+ "An account password in the library has changed."
+ ::= 9
+
+ eventLoaderConfigChange TRAP-TYPE
+ ENTERPRISE ibm3200Event
+ VARIABLES { libraryProductId,
+ librarySerNum }
+ DESCRIPTION
+ "A logical library configuration has been changed."
+ ::= 10
+
+ eventBrowserLogin TRAP-TYPE
+ ENTERPRISE ibm3200Event
+ VARIABLES { libraryProductId,
+ librarySerNum }
+ DESCRIPTION
+ "Someone logged in via Web Browser"
+ ::= 11
+
+ eventBrowserLogout TRAP-TYPE
+ ENTERPRISE ibm3200Event
+ VARIABLES { libraryProductId,
+ librarySerNum }
+ DESCRIPTION
+ "Someone logged out from Web Browser"
+ ::= 12
+
+ END
+
+--