+-- Copyright (C) 2003 by HUAWEI TECHNOLOGIES. All rights reserved
+--
+-- Description: This mib file is used for management of huawei userlog
+-- information.
+-- Reference:
+-- Version: V1.1
+-- History:
+-- tianli,2003.3.31,publish
+-- Zhang Peng,2004.5.19,Reunification version based on V1.0 .
+-- =================================================================
+
+HUAWEI-USERLOG-MIB DEFINITIONS ::= BEGIN
+
+ IMPORTS
+ OBJECT-GROUP, MODULE-COMPLIANCE
+ FROM SNMPv2-CONF
+ IpAddress, Integer32, Counter32, OBJECT-TYPE, MODULE-IDENTITY
+ FROM SNMPv2-SMI
+ hwDatacomm
+ FROM HUAWEI-MIB;
+
+ -- 1.3.6.1.4.1.2011.5.25.18
+ hwUserLogMIB MODULE-IDENTITY
+ LAST-UPDATED "200304100000Z"
+ ORGANIZATION
+ "Huawei Technologies co.,Ltd."
+ CONTACT-INFO
+ " R&D BeiJing, Huawei Technologies co.,Ltd.
+ Huawei Bld.,NO.3 Xinxi Rd.,
+ Shang-Di Information Industry Base,
+ Hai-Dian District Beijing P.R. China
+ Zip:100085
+ Http://www.huawei.com
+ E-mail:support@huawei.com "
+ DESCRIPTION
+ "The HUAWEI-USERLOG-MIB contains objects to
+ manage configuration and monitor running state
+ for userlog feature.
+ For users who access network through NAT and BAS
+ equipments, their IP addresses are generally
+ unfixed, and so it is hard to exactly locate which
+ host a certain access comes from and which user
+ initiates it. This decreases the network security.
+ User log is designed to solve the problem. User log
+ can record Network Address Translation (NAT) flow
+ information, and login/ logout information and flow
+ information of Broadband Access Server (BAS) user,
+ thus enabling the administrator know address
+ information before NAT, access record of BAS user, etc.
+ Then, network activities and operations can be queried
+ and tracked, and network availability and security are
+ improved accordingly."
+ ::= { hwDatacomm 18 }
+ --
+ -- Node definitions
+ --
+
+ -- 1.3.6.1.4.1.2011.5.25.18.1
+ hwUserlogObjects OBJECT IDENTIFIER ::= { hwUserLogMIB 1 }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.1.1
+ hwUserlogNatObjects OBJECT IDENTIFIER ::= { hwUserlogObjects 1 }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.1.1.1
+ hwUserlogNatVersion OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "NAT LOG version. Currently only version 1 is developed."
+ ::= { hwUserlogNatObjects 1 }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.1.1.2
+ hwUserlogNatSyslog OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "NAT LOG format.
+ If 1, LOG format is sysLog.
+ If 0, LOG format is UDP packet.
+ UDP packet is the default format and is recommended.
+ Syslog can be used in the case that log amount is not too large."
+ ::= { hwUserlogNatObjects 2 }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.1.1.3
+ hwUserlogNatSourceIP OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The Source IP address of NAT LOG UDP packet.
+ By default, the source IP address of the UDP packet
+ is the IP address of the interface through which the
+ router outputs the user log packet.
+ On the user log server side, the source of log
+ information can be located rapidly through identifying
+ the source IP address of the log. You are recommended
+ to configure a loopback address or router ID to function
+ as the source IP address of the UDP packet."
+ ::= { hwUserlogNatObjects 3 }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.1.1.4
+ hwUserlogNatFlowBegin OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Log the NAT flow when it is created.
+ If 1, this function is enabled.
+ If 0, this function is disabled.
+ This function will be used when real-time monitor is required.
+ The default value 0 means this function is disabled."
+ ::= { hwUserlogNatObjects 4 }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.1.1.5
+ hwUserlogNatActiveTime OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The active time for long-time existed NAT flow.
+ Unit: minute. Range: 10 minutes ~ 120 minutes.
+ When setting it, NAT flow can be logged after an interval of active time.
+ This function will be used when real-time monitor is required.
+ The default value 0 means real-time monitor function is disabled. "
+ ::= { hwUserlogNatObjects 5 }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.1.1.6
+ hwUserlogNatSlotCfgInfoTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF HwUserlogNatSlotCfgInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of NAT LOG configuration information for the specified slot.
+ By default, user log function is disabled on the interface board.
+ Only after user log function is enabled, the other configurations
+ related to user log take effect."
+ ::= { hwUserlogNatObjects 6 }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.1.1.6.1
+ hwUserlogNatSlotCfgInfoEntry OBJECT-TYPE
+ SYNTAX HwUserlogNatSlotCfgInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "NAT LOG configuration information entry for a slot."
+ INDEX { hwUserlogNatCfgSlotNumber }
+ ::= { hwUserlogNatSlotCfgInfoTable 1 }
+
+ HwUserlogNatSlotCfgInfoEntry ::=
+ SEQUENCE {
+ hwUserlogNatCfgSlotNumber
+ Integer32,
+ hwUserlogNatEnable
+ Integer32,
+ hwUserlogNatAclNumber
+ Integer32,
+ hwUserlogNatHostAddress
+ IpAddress,
+ hwUserlogNatUdpPort
+ Integer32
+ }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.1.1.6.1.1
+ hwUserlogNatCfgSlotNumber OBJECT-TYPE
+ SYNTAX Integer32 (0..15)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Slot number.
+ The object specifies which slot is configured with NAT LOG.
+ For NAT LOG, it is the slot of the egress interface
+ configured with NAT."
+ ::= { hwUserlogNatSlotCfgInfoEntry 1 }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.1.1.6.1.2
+ hwUserlogNatEnable OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The NAT LOG feature status.
+ If 1, NAT LOG is enabled.
+ If 0, NAT LOG is disabled.
+ The default value 0 means NAT LOG is disabled."
+ ::= { hwUserlogNatSlotCfgInfoEntry 2 }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.1.1.6.1.3
+ hwUserlogNatAclNumber OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Access-list number. Its range is 2000 ~ 3999.
+ The value 0 means no ACL is specified.
+ Only when NAT LOG is enabled, and ACL is configured.
+ Only NAT flow which match the ACL will be logged. "
+ ::= { hwUserlogNatSlotCfgInfoEntry 3 }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.1.1.6.1.4
+ hwUserlogNatHostAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The IP address of NAT LOG server.
+ If user log is output in UDP packet mode, user log
+ server must be configured and user log server address
+ must be specified correctly. Otherwise, user log
+ function cannot work normally.
+ The address of the destination server must be a valid
+ unicast address rather than a loop address or multicast
+ address. In principle, it should be the address of the
+ user log server that can communicate normally."
+ ::= { hwUserlogNatSlotCfgInfoEntry 4 }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.1.1.6.1.5
+ hwUserlogNatUdpPort OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The UDP Port Number of NAT LOG server. Its range is 1 ~ 65535.
+ In order to avoid confliction with general UDP port numbers,
+ you are recommended to use the UDP port number above 1024."
+ ::= { hwUserlogNatSlotCfgInfoEntry 5 }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.1.1.7
+ hwUserlogNatSlotRunInfoTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF HwUserlogNatSlotRunInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of NAT LOG running information for the specified slot."
+ ::= { hwUserlogNatObjects 7 }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.1.1.7.1
+ hwUserlogNatSlotRunInfoEntry OBJECT-TYPE
+ SYNTAX HwUserlogNatSlotRunInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "NAT LOG running information entry for a slot."
+ INDEX { hwUserlogNatRunSlotNumber }
+ ::= { hwUserlogNatSlotRunInfoTable 1 }
+
+ HwUserlogNatSlotRunInfoEntry ::=
+ SEQUENCE {
+ hwUserlogNatRunSlotNumber
+ Integer32,
+ hwUserlogNatTotalEntries
+ Counter32,
+ hwUserlogNatTotalPackets
+ Counter32,
+ hwUserlogNatFailedEntries
+ Counter32,
+ hwUserlogNatFailedPackets
+ Counter32,
+ hwUserlogNatClearRunStat
+ Integer32
+ }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.1.1.7.1.1
+ hwUserlogNatRunSlotNumber OBJECT-TYPE
+ SYNTAX Integer32 (0..15)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Slot number.
+ The object specifies on which slot the NAT LOG statistics are calculated."
+ ::= { hwUserlogNatSlotRunInfoEntry 1 }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.1.1.7.1.2
+ hwUserlogNatTotalEntries OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of NAT flow entries which are logged."
+ ::= { hwUserlogNatSlotRunInfoEntry 2 }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.1.1.7.1.3
+ hwUserlogNatTotalPackets OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of NAT LOG UDP packets generated by the device."
+ ::= { hwUserlogNatSlotRunInfoEntry 3 }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.1.1.7.1.4
+ hwUserlogNatFailedEntries OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of NAT flow entries failed in outputting."
+ ::= { hwUserlogNatSlotRunInfoEntry 4 }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.1.1.7.1.5
+ hwUserlogNatFailedPackets OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of NAT LOG UDP packets failed in outputting."
+ ::= { hwUserlogNatSlotRunInfoEntry 5 }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.1.1.7.1.6
+ hwUserlogNatClearRunStat OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Clears the running statistics for NAT LOG. Its access is write-only.
+ If 1, the running statistics for NAT LOG is resetted.
+ Other value is invalid."
+ ::= { hwUserlogNatSlotRunInfoEntry 6 }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.1.2
+ hwUserlogFlowObjects OBJECT IDENTIFIER ::= { hwUserlogObjects 2 }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.1.2.1
+ hwUserlogFlowVersion OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "BAS FLOW LOG version. Currently only version 1 is developed."
+ ::= { hwUserlogFlowObjects 1 }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.1.2.2
+ hwUserlogFlowSyslog OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "BAS FLOW LOG format.
+ If 1, LOG format is sysLog.
+ If 0, LOG format is UDP packet.
+ UDP packet is the default format, and is recommended.
+ Syslog can be used in the case that log amount is not
+ too large."
+ ::= { hwUserlogFlowObjects 2 }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.1.2.3
+ hwUserlogFlowSourceIP OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The Source IP address of BAS FLOW LOG UDP packet.
+ By default, the source IP address of the UDP packet
+ is the IP address of the interface through which the
+ router outputs the user log packet.
+ On the user log server side, the source of log
+ information can be located rapidly through identifying
+ the source IP address of the log. You are recommended
+ to configure a loopback address or router ID to function
+ as the source IP address of the UDP packet."
+ ::= { hwUserlogFlowObjects 3 }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.1.2.4
+ hwUserlogFlowFlowBegin OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Log the BAS flow when it is created.
+ If 1, this function is enabled.
+ If 0, this function is disabled.
+ This function will be used when real-time monitor is required.
+ The default value 0 means this function is disabled."
+ ::= { hwUserlogFlowObjects 4 }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.1.2.5
+ hwUserlogFlowActiveTime OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The active time for long-time existed BAS flow.
+ Its unit is minute. Its range is 10 minutes ~ 120 minutes.
+ When setting it, BAS flow can be logged after an internal of active time.
+ This function will be used when real-time monitor is required.
+ The default value 0 means real-time monitor function
+ is disabled. "
+ ::= { hwUserlogFlowObjects 5 }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.1.2.6
+ hwUserlogFlowSlotCfgInfoTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF HwUserlogFlowSlotCfgInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of BAS FLOW LOG configuration information for the specified slot.
+ By default, user log function is disabled on the interface board.
+ Only after user log function is enabled, the other configurations
+ related to user log take effect."
+ ::= { hwUserlogFlowObjects 6 }
+
+
+ -- 1.3.6.1.4.1.2011.5.25.18.1.2.6.1
+ hwUserlogFlowSlotCfgInfoEntry OBJECT-TYPE
+ SYNTAX HwUserlogFlowSlotCfgInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "BAS FLOW LOG configuration information entry for a slot."
+ INDEX { hwUserlogFlowCfgSlotNumber }
+ ::= { hwUserlogFlowSlotCfgInfoTable 1 }
+
+ HwUserlogFlowSlotCfgInfoEntry ::=
+ SEQUENCE {
+ hwUserlogFlowCfgSlotNumber
+ Integer32,
+ hwUserlogFlowEnable
+ Integer32,
+ hwUserlogFlowAclNumber
+ Integer32,
+ hwUserlogFlowHostAddress
+ IpAddress,
+ hwUserlogFlowUdpPort
+ Integer32
+ }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.1.2.6.1.1
+ hwUserlogFlowCfgSlotNumber OBJECT-TYPE
+ SYNTAX Integer32 (0..15)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Slot number.
+ The ojects specifies which slot is configured with BAS FLOW LOG. "
+ ::= { hwUserlogFlowSlotCfgInfoEntry 1 }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.1.2.6.1.2
+ hwUserlogFlowEnable OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The BAS FLOW LOG feature status.
+ If 1, BAS FLOW LOG is enabled.
+ If 0, BAS FLOW LOG is disabled.
+ The default value 0 means BAS FLOW LOG is disabled."
+ ::= { hwUserlogFlowSlotCfgInfoEntry 2 }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.1.2.6.1.3
+ hwUserlogFlowAclNumber OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Access-list number. Its range is 2000 ~ 3999.
+ The value 0 means no ACL is specified.
+ Only when BAS FLOW LOG is enabled, the ACL be configured.
+ Only BAS flow which match the ACL will be logged. "
+ ::= { hwUserlogFlowSlotCfgInfoEntry 3 }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.1.2.6.1.4
+ hwUserlogFlowHostAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The IP address of BAS FLOW LOG server.
+ If user log is output in UDP packet mode, user log
+ server must be configured and user log server address
+ must be specified correctly. Otherwise, user log
+ function cannot work normally.
+ The address of the destination server must be a valid
+ unicast address rather than a loop address or multicast
+ address. In principle, it should be the address of the
+ user log server that can communicate normally."
+ ::= { hwUserlogFlowSlotCfgInfoEntry 4 }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.1.2.6.1.5
+ hwUserlogFlowUdpPort OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The UDP Port Number of BAS FLOW LOG server. Its range is 1 ~ 65535.
+ In order to avoid confliction with general UDP port numbers,
+ you are recommended to use the UDP port number above 1024."
+ ::= { hwUserlogFlowSlotCfgInfoEntry 5 }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.1.2.7
+ hwUserlogFlowSlotRunInfoTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF HwUserlogFlowSlotRunInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of BAS FLOW LOG running information for the specified slot."
+ ::= { hwUserlogFlowObjects 7 }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.1.2.7.1
+ hwUserlogFlowSlotRunInfoEntry OBJECT-TYPE
+ SYNTAX HwUserlogFlowSlotRunInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Running Information Entry for a slot."
+ INDEX { hwUserlogFlowRunSlotNumber }
+ ::= { hwUserlogFlowSlotRunInfoTable 1 }
+
+ HwUserlogFlowSlotRunInfoEntry ::=
+ SEQUENCE {
+ hwUserlogFlowRunSlotNumber
+ Integer32,
+ hwUserlogFlowTotalEntries
+ Counter32,
+ hwUserlogFlowTotalPackets
+ Counter32,
+ hwUserlogFlowFailedEntries
+ Counter32,
+ hwUserlogFlowFailedPackets
+ Counter32,
+ hwUserlogFlowClearRunStat
+ Integer32
+ }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.1.2.7.1.1
+ hwUserlogFlowRunSlotNumber OBJECT-TYPE
+ SYNTAX Integer32 (0..15)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Slot number.
+ The object specifies on which slot the BAS FLOW LOG statistics are calculated."
+ ::= { hwUserlogFlowSlotRunInfoEntry 1 }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.1.2.7.1.2
+ hwUserlogFlowTotalEntries OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of BAS FLOW Entries which are logged. "
+ ::= { hwUserlogFlowSlotRunInfoEntry 2 }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.1.2.7.1.3
+ hwUserlogFlowTotalPackets OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of FLOW LOG UDP packet generated by the device. "
+ ::= { hwUserlogFlowSlotRunInfoEntry 3 }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.1.2.7.1.4
+ hwUserlogFlowFailedEntries OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of BAS FLOW entries failed in outputting. "
+ ::= { hwUserlogFlowSlotRunInfoEntry 4 }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.1.2.7.1.5
+ hwUserlogFlowFailedPackets OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of BAS FLOW LOG UDP packet failed in outputting."
+ ::= { hwUserlogFlowSlotRunInfoEntry 5 }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.1.2.7.1.6
+ hwUserlogFlowClearRunStat OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Clears the running statistics for FLOW LOG. Its access is write-only.
+ If 1, the running statistics for FLOW LOG is resetted.
+ Other value is invalid."
+ ::= { hwUserlogFlowSlotRunInfoEntry 6 }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.1.3
+ hwUserlogAccessObjects OBJECT IDENTIFIER ::= { hwUserlogObjects 3 }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.1.3.1
+ hwUserlogAccessVersion OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "BAS ACCESS LOG version. Currently only version 1 is developed."
+ ::= { hwUserlogAccessObjects 1 }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.1.3.2
+ hwUserlogAccessSyslog OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "BAS ACCESS LOG format.
+ If 1, LOG format is sysLog;
+ If 0, LOG format is UDP packet.
+ UDP packet is the default format, and is recommended.
+ Syslog can be used in the case that log amount is not too large."
+ ::= { hwUserlogAccessObjects 2 }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.1.3.3
+ hwUserlogAccessSourceIP OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The Source IP address of BAS ACCESS LOG UDP packet.
+ By default, the source IP address of the UDP packet
+ is the IP address of the interface through which the
+ router outputs the user log packet.
+ On the user log server side, the source of log
+ information can be located rapidly through identifying
+ the source IP address of the log. You are recommended
+ to configure a loopback address or router ID to function
+ as the source IP address of the UDP packet."
+ ::= { hwUserlogAccessObjects 3 }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.1.3.4
+ hwUserlogAccessSlotCfgInfoTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF HwUserlogAccessSlotCfgInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of BAS ACCESS LOG configuration information for the specified slot."
+ ::= { hwUserlogAccessObjects 4 }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.1.3.4.1
+ hwUserlogAccessSlotCfgInfoEntry OBJECT-TYPE
+ SYNTAX HwUserlogAccessSlotCfgInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "BAS ACCESS LOG configuration information entry for a slot."
+ INDEX { hwUserlogAccessCfgSlotNumber }
+ ::= { hwUserlogAccessSlotCfgInfoTable 1 }
+
+ HwUserlogAccessSlotCfgInfoEntry ::=
+ SEQUENCE {
+ hwUserlogAccessCfgSlotNumber
+ Integer32,
+ hwUserlogAccessEnable
+ Integer32,
+ hwUserlogAccessHostAddress
+ IpAddress,
+ hwUserlogAccessUdpPort
+ Integer32
+ }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.1.3.4.1.1
+ hwUserlogAccessCfgSlotNumber OBJECT-TYPE
+ SYNTAX Integer32 (0..15)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Slot number.
+ The object specifies which slot is configured with BAS ACCESS LOG. "
+ ::= { hwUserlogAccessSlotCfgInfoEntry 1 }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.1.3.4.1.2
+ hwUserlogAccessEnable OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The BAS ACCESS LOG feature status.
+ If 1, BAS ACCESS LOG is enabled.
+ If 0, BAS ACCESS LOG is disabled.
+ The default value 0 means BAS ACCESS LOG is disabled."
+ ::= { hwUserlogAccessSlotCfgInfoEntry 2 }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.1.3.4.1.3
+ hwUserlogAccessHostAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The IP address of BAS ACCESS LOG server.
+ If user log is output in UDP packet mode, user log
+ server must be configured and user log server address
+ must be specified correctly. Otherwise, user log
+ function cannot work normally.
+ The address of the destination server must be a valid
+ unicast address rather than a loop address or multicast
+ address. In principle, it should be the address of the
+ user log server that can communicate normally."
+ ::= { hwUserlogAccessSlotCfgInfoEntry 3 }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.1.3.4.1.4
+ hwUserlogAccessUdpPort OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The UDP Port Number of BAS ACCESS LOG server. Its range is 1 ~ 65535.
+ In order to avoid confliction with general UDP port numbers,
+ you are recommended to use the UDP port number above 1024."
+ ::= { hwUserlogAccessSlotCfgInfoEntry 4 }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.1.3.5
+ hwUserlogAccessSlotRunInfoTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF HwUserlogAccessSlotRunInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of BAS ACCESS LOG running information
+ for the specified slot."
+ ::= { hwUserlogAccessObjects 5 }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.1.3.5.1
+ hwUserlogAccessSlotRunInfoEntry OBJECT-TYPE
+ SYNTAX HwUserlogAccessSlotRunInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Running Information Entry for a slot."
+ INDEX { hwUserlogAccessRunSlotNumber }
+ ::= { hwUserlogAccessSlotRunInfoTable 1 }
+
+ HwUserlogAccessSlotRunInfoEntry ::=
+ SEQUENCE {
+ hwUserlogAccessRunSlotNumber
+ Integer32,
+ hwUserlogAccessTotalEntries
+ Counter32,
+ hwUserlogAccessTotalPackets
+ Counter32,
+ hwUserlogAccessFailedEntries
+ Counter32,
+ hwUserlogAccessFailedPackets
+ Counter32,
+ hwUserlogAccessClearRunStat
+ Integer32
+ }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.1.3.5.1.1
+ hwUserlogAccessRunSlotNumber OBJECT-TYPE
+ SYNTAX Integer32 (0..15)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Slot number.
+ The object specifies on which slot the BAS ACCESS LOG statistics
+ are calculated."
+ ::= { hwUserlogAccessSlotRunInfoEntry 1 }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.1.3.5.1.2
+ hwUserlogAccessTotalEntries OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of BAS ACCESS records which are logged. "
+ ::= { hwUserlogAccessSlotRunInfoEntry 2 }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.1.3.5.1.3
+ hwUserlogAccessTotalPackets OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of ACCESS LOG UDP packet generated by the router."
+ ::= { hwUserlogAccessSlotRunInfoEntry 3 }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.1.3.5.1.4
+ hwUserlogAccessFailedEntries OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of BAS ACCESS entries failed in outputting."
+ ::= { hwUserlogAccessSlotRunInfoEntry 4 }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.1.3.5.1.5
+ hwUserlogAccessFailedPackets OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of BAS ACCESS LOG UDP packet failed in outputting."
+ ::= { hwUserlogAccessSlotRunInfoEntry 5 }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.1.3.5.1.6
+ hwUserlogAccessClearRunStat OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Clear the running statistics for ACCESS LOG. Its access is write-only.
+ If 1, the running statistics for ACCESS LOG is resetted,
+ the other value is invalid."
+ ::= { hwUserlogAccessSlotRunInfoEntry 6 }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.2
+ hwUserlogNotifications OBJECT IDENTIFIER ::= { hwUserLogMIB 2 }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.3
+ hwUserlogConformance OBJECT IDENTIFIER ::= { hwUserLogMIB 3 }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.3.1
+ hwUserlogCompliances OBJECT IDENTIFIER ::= { hwUserlogConformance 1 }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.3.1.1
+ hwUserlogCompliance MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION
+ "The compliance statement for entities which
+ implement the Huawei Userlog mib."
+ MODULE -- this module
+ MANDATORY-GROUPS { hwUserlogMandatoryGroup }
+ ::= { hwUserlogCompliances 1 }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.3.2
+ hwUserlogGroups OBJECT IDENTIFIER ::= { hwUserlogConformance 2 }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.3.2.1
+ hwUserlogMandatoryGroup OBJECT-GROUP
+ OBJECTS { hwUserlogNatEnable, hwUserlogNatHostAddress, hwUserlogNatUdpPort, hwUserlogFlowEnable, hwUserlogFlowHostAddress,
+ hwUserlogFlowUdpPort, hwUserlogAccessEnable, hwUserlogAccessHostAddress, hwUserlogAccessUdpPort }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing mandatory Userlog information."
+ ::= { hwUserlogGroups 1 }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.3.2.2
+ hwUserlogConfigGroup OBJECT-GROUP
+ OBJECTS { hwUserlogNatVersion, hwUserlogNatSyslog, hwUserlogNatSourceIP, hwUserlogNatFlowBegin, hwUserlogNatActiveTime,
+ hwUserlogNatCfgSlotNumber, hwUserlogNatEnable, hwUserlogNatAclNumber, hwUserlogNatHostAddress, hwUserlogNatUdpPort,
+ hwUserlogFlowVersion, hwUserlogFlowSyslog, hwUserlogFlowSourceIP, hwUserlogFlowFlowBegin, hwUserlogFlowActiveTime,
+ hwUserlogFlowCfgSlotNumber, hwUserlogFlowEnable, hwUserlogFlowAclNumber, hwUserlogFlowHostAddress, hwUserlogFlowUdpPort,
+ hwUserlogAccessVersion, hwUserlogAccessSyslog, hwUserlogAccessSourceIP, hwUserlogAccessCfgSlotNumber, hwUserlogAccessEnable,
+ hwUserlogAccessHostAddress, hwUserlogAccessUdpPort }
+ STATUS current
+ DESCRIPTION
+ "All configurable parameters of Userlog feature."
+ ::= { hwUserlogGroups 2 }
+
+ -- 1.3.6.1.4.1.2011.5.25.18.3.2.3
+ hwUserlogInfoGroup OBJECT-GROUP
+ OBJECTS { hwUserlogNatTotalEntries, hwUserlogNatTotalPackets, hwUserlogNatFailedEntries, hwUserlogNatFailedPackets, hwUserlogFlowTotalEntries,
+ hwUserlogFlowTotalPackets, hwUserlogFlowFailedEntries, hwUserlogFlowFailedPackets, hwUserlogAccessTotalEntries, hwUserlogAccessTotalPackets,
+ hwUserlogAccessFailedEntries, hwUserlogAccessFailedPackets }
+ STATUS current
+ DESCRIPTION
+ "All running information of Userlog feature."
+ ::= { hwUserlogGroups 3 }
+
+END