+CTRON-POWER-SUPPLY-MIB DEFINITIONS ::= BEGIN
+
+ -- ctron-power-supply-mib.txt The power supply MIB
+ -- Revision: 1.01.02
+ -- Part Number:
+ -- Date: March 26, 1997
+
+ -- Cabletron Systems, Inc.
+ -- 35 Industrial Way, P.O. Box 5005
+ -- Rochester, NH 03867-0505
+ -- (603) 332-9400
+ -- support@ctron.com
+
+ -- This module provides authoritative definitions for Cabletron's
+ -- enterprise-specific chassis MIB.
+ --
+ -- This module will be extended, as needed.
+ --
+
+ -- Cabletron Systems reserves the right to make changes in
+ -- specification and other information contained in this document
+ -- without prior notice. The reader should consult Cabletron Systems
+ -- to determine whether any such changes have been made.
+ --
+ -- In no event shall Cabletron Systems be liable for any incidental,
+ -- indirect, special, or consequential damages whatsoever (including
+ -- but not limited to lost profits) arising out of or related to this
+ -- document or the information contained in it, even if Cabletron
+ -- Systems has been advised of, known, or should have known, the
+ -- possibility of such damages.
+ --
+ -- Cabletron grants vendors, end-users, and other interested parties
+ -- a non-exclusive license to use this Specification in connection
+ -- with the management of Cabletron products.
+
+ -- Copyright August 95 Cabletron Systems
+
+
+ -- This MIB describes objects for MMAC+ style power supplies.
+
+ IMPORTS
+ ctps
+ FROM CTRON-MIB-NAMES
+ OBJECT-TYPE
+ FROM RFC-1212;
+
+
+
+ --=============== group definitions ===================
+
+ chPower OBJECT IDENTIFIER ::= { ctps 1 }
+ boardPower OBJECT IDENTIFIER ::= { ctps 2 }
+ psPower OBJECT IDENTIFIER ::= { ctps 3 }
+ bbuPower OBJECT IDENTIFIER ::= { ctps 4 }
+ termPower OBJECT IDENTIFIER ::= { ctps 5 }
+
+ --=============== chPower group ====================
+
+ -- Chassis Power Group
+ -- Implementation of the Chassis Power group is optional.
+ -- It needs to be supported when an EM is present and operational
+ -- in the chassis.
+ -- This group covers information on the chassis power available.
+
+ chPowerOperationalStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ powerAC(1),
+ powerACRedundant(2),
+ powerDC(3),
+ powerDCRedundant(4),
+ battery(5)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This object reflects the overall status of the chassis's
+ power supply in terms of how the power is being delivered
+ to the chassis."
+ ::= { chPower 1 }
+
+ chPowerMainVoltageStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ powerOK(1),
+ overCurrent(2),
+ overVoltage(3),
+ underVoltage(4)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This object reflects the state of the main voltage
+ rail within the chassis. The power on this rail may
+ be delivered by AC supplies, DC supplies or battery
+ supplies."
+ ::= { chPower 2 }
+
+ chPowerMainVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The voltage of the chassis's main voltage rail. This rail
+ carries power to all the modules in the chassis. It has
+ an allowable range of 40 volts to 60 volts DC. The value
+ of this object is the actual voltage * 10."
+ ::= { chPower 3 }
+
+ chPowerTotalSupply OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The total power being supplied by the chassis's power
+ supplies to the chassis. The value of this object is the
+ actual watts."
+ ::= { chPower 4 }
+
+ chPowerTotalLoad OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The total load being presented by the chassis to the
+ chassis's power supplies. The value of
+ this object is the actual watts."
+ ::= { chPower 5 }
+
+ chPowerMaxSupply OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The maximum power that could de supplied by the chassis's power
+ supplies to the chassis. The value of this object is the
+ actual watts."
+ ::= { chPower 6 }
+
+ chPowerMaxLoad OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The maximum load that could be presented by the chassis to the
+ chassis's power supplies. The value of
+ this object is the actual watts."
+ ::= { chPower 7 }
+
+ chPowerTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ChPowerEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of power lines or busses on the chassis's backplane."
+ ::= { chPower 8 }
+
+ chPowerEntry OBJECT-TYPE
+ SYNTAX ChPowerEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A slot entry containing objects for a particular
+ module and associated power line."
+ INDEX { chPowerLineID }
+ ::= { chPowerTable 1 }
+
+ ChPowerEntry ::=
+ SEQUENCE {
+ chPowerLineID
+ INTEGER,
+ chPowerLineType
+ OBJECT IDENTIFIER,
+ chPowerLineTotalSupply
+ INTEGER,
+ chPowerLineTotalLoad
+ INTEGER,
+ chPowerLineMaxSupply
+ INTEGER,
+ chPowerLineMaxLoad
+ INTEGER
+ }
+
+ chPowerLineID OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A unique value used to identify a particular power line on
+ the chassis's backplane."
+ ::= { chPowerEntry 1 }
+
+ chPowerLineType OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The type of power. For example, a power line that supplies
+ DC current at a nominal voltage of 40 to 57 volts or a
+ power line that supplies AC current at a nominal volatge of
+ 110v."
+ ::= { chPowerEntry 2 }
+
+ chPowerLineTotalSupply OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The total power being supplied by the chassis's power
+ supplies to the chassis on this power line. The value
+ of this object is the actual watts."
+ ::= { chPowerEntry 3 }
+
+ chPowerLineTotalLoad OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The total load being presented by the chassis to the
+ chassis's power supplies on this power line. This value
+ will be zero if unknown The value of this object is the
+ actual watts."
+ ::= { chPowerEntry 4 }
+
+ chPowerLineMaxSupply OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The maximum power that could de supplied by the chassis's power
+ supplies to the chassison this power line. The value of
+ this object is the actual watts."
+ ::= { chPowerEntry 5 }
+
+ chPowerLineMaxLoad OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The maximum load that could be presented by the chassis to the
+ chassis's power supplies on this power line. The value of
+ this object is the actual watts."
+ ::= { chPowerEntry 6 }
+
+ chPowerDiagVoltageStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ powerOK(1),
+ overCurrent(2),
+ overVoltage(3),
+ underVoltage(4)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This object reflects the state of the diag voltage
+ rail within the chassis."
+ ::= { chPower 9 }
+
+ chPowerDiagVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The voltage of the chassis's diag voltage rail. This rail
+ carries power to all the modules in the chassis. It has
+ an allowable range of 4.75 volts to 5.25 volts DC. The value
+ of this object is the actual voltage * 10."
+ ::= { chPower 10 }
+
+ --=============== boardPower group ====================
+
+ -- Board Power Group
+ -- This group covers information on the use of power within the
+ -- chassis by the networking boards.
+
+ boardPowerSlotStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BoardPowerSlotStatusEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of networking modules installed in this chassis."
+ ::= { boardPower 1 }
+
+ boardPowerSlotStatusEntry OBJECT-TYPE
+ SYNTAX BoardPowerSlotStatusEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A slot entry containing objects for a particular
+ module."
+ INDEX { boardPowerSlotStatusID }
+ ::= { boardPowerSlotStatusTable 1 }
+
+ BoardPowerSlotStatusEntry ::=
+ SEQUENCE {
+ boardPowerSlotStatusID
+ INTEGER,
+ boardPowerOperationalStatus
+ INTEGER,
+ boardPowerAdminStatus
+ INTEGER,
+ boardPowerLocalAdminStatus
+ INTEGER,
+ boardPowerLocalStatus
+ INTEGER,
+ boardPowerShutdownAdmin
+ INTEGER,
+ boardPowerPriority
+ INTEGER,
+ boardPowerMaxInputPower
+ INTEGER,
+ boardPowerManagement
+ INTEGER
+ }
+
+ boardPowerSlotStatusID OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The slot number of a chassis slot in which this board is
+ installed. This object is similiar to chSlotID in the
+ Chassis MIB."
+ ::= { boardPowerSlotStatusEntry 1 }
+
+ boardPowerOperationalStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ powerOn(1),
+ powerOff(2),
+ reset(3),
+ overVoltage(4),
+ underVoltage(5),
+ overCurrent(6),
+ overCurrentShutdown(7),
+ temperatureShutdown(8),
+ remotePowerOff(9),
+ powerConservationShutdown(10),
+ frontPanelPowerOff(11)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This object reflects the status of the module's
+ DC-DC converter power supply."
+ ::= { boardPowerSlotStatusEntry 2 }
+
+ boardPowerAdminStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ powerOn(1),
+ powerOff(2),
+ reset(3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This object controls the operation of the module's
+ DC-DC power supply. If the value 3 is written to
+ this object then the value of the object will be
+ set to 1 after the reset is performed."
+ DEFVAL { powerOn }
+ ::= { boardPowerSlotStatusEntry 3 }
+
+ boardPowerLocalAdminStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ localMode(1),
+ secureMode(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This object controls the operation of the module's
+ front panel button. In local mode this button may
+ be used to locally control the operation of the
+ DC-DC converter, i.e. power on, power off and
+ reset. In secure mode a request the state of the
+ front panel button is reflected in the object
+ boardPowerOperationalStatus. In secure mode
+ the front panel button has no effect locally."
+ DEFVAL { localMode }
+ ::= { boardPowerSlotStatusEntry 4 }
+
+ boardPowerLocalStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ resetRequest(1),
+ powerDownRequest(2),
+ powerOnRequest(3),
+ normal(4)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This object reflects the state of the module's front
+ panel button."
+ ::= { boardPowerSlotStatusEntry 5 }
+
+ boardPowerShutdownAdmin OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled(1),
+ disabled(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This object controls whether or not the module should
+ auto power down due to an fault condition."
+ DEFVAL { disabled }
+ ::= { boardPowerSlotStatusEntry 6 }
+
+ boardPowerPriority OBJECT-TYPE
+ SYNTAX INTEGER (1..14)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The module's power-up and power down priority. This is a
+ value of 1 to 14 and is used to decide which modules are
+ allowed to power on in the event that power demand of the
+ chassis is greater than the total power supply. The default
+ value is 14, highest priority. When two modules have equal
+ priority then the module in the lowest slot wins."
+ DEFVAL { 14 }
+ ::= { boardPowerSlotStatusEntry 7 }
+
+ boardPowerMaxInputPower OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The maximum input power that this module is allowed
+ to consume. The value of this object is actual
+ watts."
+ ::= { boardPowerSlotStatusEntry 8 }
+
+ boardPowerManagement OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(1),
+ enabled(2),
+ not-supported(7)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Module power management status."
+ DEFVAL { not-supported }
+ ::= { boardPowerSlotStatusEntry 9 }
+
+ boardPowerSlotTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BoardPowerSlotEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of networking modules and associated power lines
+ installed in this chassis."
+ ::= { boardPower 2 }
+
+ boardPowerSlotEntry OBJECT-TYPE
+ SYNTAX BoardPowerSlotEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A slot entry containing objects for a particular
+ module and associated power line."
+ INDEX { boardPowerSlotID, boardPowerID }
+ ::= { boardPowerSlotTable 1 }
+
+ BoardPowerSlotEntry ::=
+ SEQUENCE {
+ boardPowerSlotID
+ INTEGER,
+ boardPowerID
+ INTEGER,
+ boardPowerType
+ OBJECT IDENTIFIER,
+ boardPowerStatus
+ INTEGER,
+ boardPowerVoltage
+ INTEGER,
+ boardPowerCurrent
+ INTEGER,
+ boardPowerMaxVoltage
+ INTEGER,
+ boardPowerMinVoltage
+ INTEGER,
+ boardPowerMaxPower
+ INTEGER
+ }
+
+ boardPowerSlotID OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The slot number of a chassis slot in which this board is
+ installed. This object is similiar to chSlotID in the
+ Chassis MIB."
+ ::= { boardPowerSlotEntry 1 }
+
+ boardPowerID OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A unique value used to identify a particular power line."
+ ::= { boardPowerSlotEntry 2 }
+
+ boardPowerType OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The type of power. For example, a power line that supplies
+ DC current at a nominal voltage of 40 to 57 volts or a
+ power line that supplies AC current at a nominal volatge of
+ 110v."
+ ::= { boardPowerSlotEntry 3 }
+
+ boardPowerStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ powerOK(1),
+ powerOff(2),
+ overCurrent(3),
+ overVoltage(4),
+ underVoltage(5)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This object reflects the status of this power line."
+ ::= { boardPowerSlotEntry 4 }
+
+ boardPowerVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The voltage reading for the power line. The value of this
+ object is actual voltage * 100."
+ ::= { boardPowerSlotEntry 5 }
+
+ boardPowerCurrent OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The current reading for the power line. The value of this
+ object is the actual amperage * 100. If this reading is not
+ implemented then value will be zero."
+ ::= { boardPowerSlotEntry 6 }
+
+ boardPowerMaxVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The maximum voltage for this power line. If the voltage
+ reading for this power line is greater than this value
+ then the power line is considered to be in an overvolatge
+ condition. The value of this object is in voltage * 100."
+ ::= { boardPowerSlotEntry 7 }
+
+ boardPowerMinVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The minimum voltage for this power line. If the voltage
+ reading for this power line is less than this value
+ then the power line is considered to be in an undervolatge
+ condition. The value of this object is voltage * 100."
+ ::= { boardPowerSlotEntry 8 }
+
+ boardPowerMaxPower OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The maximum power for this power line. If the power calculated
+ for this power line is greater than this value then the
+ power line is considered to be in an overload condition.
+ The value of this object is in watts."
+ ::= { boardPowerSlotEntry 9 }
+
+ --=============== psPower group ====================
+
+ -- AC and DC Power Supply Power Group
+ -- This group covers information on the use of power within the
+ -- chassis by the networking boards.
+
+ psPowerSlotStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PsPowerSlotStatusEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of AC & DC power supplies installed in this chassis."
+ ::= { psPower 1 }
+
+ psPowerSlotStatusEntry OBJECT-TYPE
+ SYNTAX PsPowerSlotStatusEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A slot entry containing objects for a particular
+ power supply."
+ INDEX { psPowerSlotStatusID }
+ ::= { psPowerSlotStatusTable 1 }
+
+ PsPowerSlotStatusEntry ::=
+ SEQUENCE {
+ psPowerSlotStatusID
+ INTEGER,
+ psPowerOperationalStatus
+ INTEGER,
+ psPowerAdminStatus
+ INTEGER,
+ psPowerMaxOutputPower
+ INTEGER
+ }
+
+ psPowerSlotStatusID OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The slot number of a chassis slot in which this AC power
+ supply is installed. This object is similiar
+ to chSlotID in the Chassis MIB."
+ ::= { psPowerSlotStatusEntry 1 }
+
+ psPowerOperationalStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ powerOn(1),
+ powerOff(2),
+ reset(3),
+ overVoltage(4),
+ underVoltage(5),
+ overCurrent(6),
+ overCurrentShutdown(7),
+ temperatureShutdown(8),
+ remotePowerOff(9)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This object reflects the status of the module's
+ DC-DC converter power supply."
+ ::= { psPowerSlotStatusEntry 2 }
+
+ psPowerAdminStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ powerOn(1),
+ powerOff(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This object controls the operation of power supply."
+ DEFVAL { powerOn }
+ ::= { psPowerSlotStatusEntry 3 }
+
+ psPowerMaxOutputPower OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The maximum power that this power supply is allowed
+ to ouput. The value of this object is watts."
+ ::= { psPowerSlotStatusEntry 4 }
+
+ psPowerSlotTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PsPowerSlotEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of power supplies and associated power lines
+ installed in this chassis."
+ ::= { psPower 2 }
+
+ psPowerSlotEntry OBJECT-TYPE
+ SYNTAX PsPowerSlotEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A slot entry containing objects for a particular
+ power line on a particular power supply."
+ INDEX { psPowerSlotID, psPowerID }
+ ::= { psPowerSlotTable 1 }
+
+ PsPowerSlotEntry ::=
+ SEQUENCE {
+ psPowerSlotID
+ INTEGER,
+ psPowerID
+ INTEGER,
+ psPowerType
+ OBJECT IDENTIFIER,
+ psPowerStatus
+ INTEGER,
+ psPowerAdmin
+ INTEGER,
+ psPowerVoltage
+ INTEGER,
+ psPowerCurrent
+ INTEGER,
+ psPowerLineFrequency
+ INTEGER,
+ psPowerMaxVoltage
+ INTEGER,
+ psPowerMinVoltage
+ INTEGER,
+ psPowerMaxPower
+ INTEGER
+ }
+
+ psPowerSlotID OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The slot number of a chassis slot in which this Power
+ supply is installed. This object is similiar to
+ chSlotID in the Chassis MIB."
+ ::= { psPowerSlotEntry 1 }
+
+ psPowerID OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A unique value used to identify a particular power line."
+ ::= { psPowerSlotEntry 2 }
+
+ psPowerType OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The type of power. For example, a power line that supplies
+ DC current at a nominal voltage of 40 to 57 volts or a
+ power line that supplies AC current at a nominal volatge of
+ 110v."
+ ::= { psPowerSlotEntry 3 }
+
+ psPowerStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ powerOK(1),
+ powerOff(2),
+ overCurrent(3),
+ overVoltage(4),
+ underVoltage(5)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This object reflects the status of the power line."
+ ::= { psPowerSlotEntry 4 }
+
+ psPowerAdmin OBJECT-TYPE
+ SYNTAX INTEGER {
+ powerOn(1),
+ powerOff(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This object controls the operation of power supply."
+ DEFVAL { powerOn }
+ ::= { psPowerSlotEntry 5 }
+
+ psPowerVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The voltage reading for the power line. The value of this
+ object is the actual voltage * 100."
+ ::= { psPowerSlotEntry 6 }
+
+ psPowerCurrent OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The current reading for the power line. The value of this
+ object is amperage * 100. If this reading is not implemented
+ then value will be zero."
+ ::= { psPowerSlotEntry 7 }
+
+ psPowerLineFrequency OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The line frequency for the power line. The value of this
+ object is the actual frequency in Hertz * 10. If this
+ reading is not implemented then value will be zero."
+ ::= { psPowerSlotEntry 8 }
+
+ psPowerMaxVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The maximum voltage for this power line. If the voltage
+ reading for this power line is greater than this value
+ then the power line is considered to be in an over volatge
+ condition. The value of this object is voltage * 100."
+ ::= { psPowerSlotEntry 9 }
+
+ psPowerMinVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The minimum voltage for this power line. If the voltage
+ reading for this power line is greater than this value
+ then the power line is considered to be in an over volatge
+ condition. The value of this object is voltage * 100."
+ ::= { psPowerSlotEntry 10 }
+
+ psPowerMaxPower OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The maximum power for this power line. If the power calculated
+ for this power line is greater than this value then the
+ power line is considered to be in an overload condition.
+ The value of this object is watts."
+ ::= { psPowerSlotEntry 11 }
+
+ --=============== bbuPower group ====================
+
+ -- Battery Backup Unit Power Group
+ -- This group covers information on the use of power within the
+ -- chassis by the battery backup unit.
+
+ --=============== termPower group ====================
+
+ -- INB Termination Module Power Group
+ -- This group covers information on the use of power within the
+ -- chassis by the INB termination modules.
+
+ termPowerStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ powerOK(1),
+ overCurrent(2),
+ overVoltage(3),
+ underVolatge(4),
+ overPower(5)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This object reflects the status of the chassis's termination
+ voltage rail."
+ ::= { termPower 1 }
+
+ termPowerVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The voltage of the chassis's termination voltage rail.
+ This rail carries power to INB terminator cards in the
+ chassis. It has an allowalble range of 3.3 Volt + or -
+ 5%.The value of this object is voltage * 100."
+ ::= { termPower 2 }
+
+ termPowerCurrent OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The current on the chassis's termination voltage rail.
+ The value of this object is the actual amperage * 100.
+ If this reading is not implemented then the value will
+ be zero."
+ ::= { termPower 3 }
+
+ termPowerModule1Status OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal(1),
+ iNBaFault(2),
+ iNBbFault(3),
+ fault(4),
+ termModuleNotInstalled(5),
+ unknown(6)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This object reflects the state of the INB termination
+ module number 1. A value of normal(1) reflects that
+ both busses are normal. A value of fault(4) reflects
+ that both busses are in a fault condition."
+ ::= { termPower 4 }
+
+ termPowerModule2Status OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal(1),
+ iNBaFault(2),
+ iNBbFault(3),
+ fault(4),
+ termModuleNotInstalled(5),
+ unknown(6)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This object reflects the state of the INB termination
+ module number 2. A value of normal(1) reflects that
+ both busses are normal. A value of fault(4) reflects
+ that both busses are in a fault condition."
+ ::= { termPower 5 }
+
+END