summaryrefslogtreecommitdiff
path: root/MIBS/enterasys/CTINB2-MIB
diff options
context:
space:
mode:
Diffstat (limited to 'MIBS/enterasys/CTINB2-MIB')
-rw-r--r--MIBS/enterasys/CTINB2-MIB212
1 files changed, 212 insertions, 0 deletions
diff --git a/MIBS/enterasys/CTINB2-MIB b/MIBS/enterasys/CTINB2-MIB
new file mode 100644
index 0000000..ddac373
--- /dev/null
+++ b/MIBS/enterasys/CTINB2-MIB
@@ -0,0 +1,212 @@
+CTINB2-MIB DEFINITIONS ::= BEGIN
+
+ -- ctinb2-mib.txt
+ -- Revision: 00.00.02
+ -- Date: October 23, 1998
+
+ -- Cabletron Systems, Inc.
+ -- 35 Industrial Way, P.O. Box 5005
+ -- Rochester, NH 03867-0505
+ -- (603) 332-9400
+ -- support@ctron.com
+
+ -- This module provides authoritative definitions for Cabletron's
+ -- INB2 MIB.
+ --
+ -- This module will be extended, as needed.
+
+ -- Cabletron Systems reserves the right to make changes in
+ -- specification and other information contained in this document
+ -- without prior notice. The reader should consult Cabletron Systems
+ -- to determine whether any such changes have been made.
+ --
+ -- In no event shall Cabletron Systems be liable for any incidental,
+ -- indirect, special, or consequential damages whatsoever (including
+ -- but not limited to lost profits) arising out of or related to this
+ -- document or the information contained in it, even if Cabletron
+ -- Systems has been advised of, known, or should have known, the
+ -- possibility of such damages.
+ --
+ -- Cabletron grants vendors, end-users, and other interested parties
+ -- a non-exclusive license to use this Specification in connection
+ -- with the management of Cabletron products.
+
+ -- Copyright September 98 Cabletron Systems
+
+IMPORTS
+ OBJECT-TYPE FROM RFC-1212
+ ctINBinfo2 FROM CTRON-MIB-NAMES ;
+
+--
+-- The Utilization group
+--
+
+ ctInbUtil OBJECT IDENTIFIER ::= { ctINBinfo2 1 }
+
+ ctInbUtilInterval OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The length of the sampling interval in seconds used for all INB
+ utilization measurements and calculations."
+ DEFVAL { 1 }
+ ::= { ctInbUtil 1 }
+
+
+ ctInbUtilTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CtInbUtilEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of byte counts and absolute utilization percentages reflecting
+ data transferred via the INB during the last sampling interval."
+ ::= { ctInbUtil 2 }
+
+ ctInbUtilEntry OBJECT-TYPE
+ SYNTAX CtInbUtilEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Byte counts and utilization percentages reflecting data transferred
+ from a source module to a destination module via the INB."
+ INDEX { ctInbUtilSrcSlot, ctInbUtilDestSlot }
+ ::= { ctInbUtilTable 1 }
+
+ CtInbUtilEntry ::=
+ SEQUENCE {
+ ctInbUtilSrcSlot
+ INTEGER,
+ ctInbUtilDestSlot
+ INTEGER,
+ ctInbUtilHiByteCountA
+ INTEGER,
+ ctInbUtilLoByteCountA
+ INTEGER,
+ ctInbUtilHiByteCountB
+ INTEGER,
+ ctInbUtilLoByteCountB
+ INTEGER,
+ ctInbUtilAbsoluteA
+ INTEGER,
+ ctInbUtilAbsoluteB
+ INTEGER,
+ ctInbUtilAbsoluteTotal
+ INTEGER
+ }
+
+ ctInbUtilSrcSlot OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The chassis slot number containing the module from which bytes are
+ transmitted onto the INB."
+ ::= { ctInbUtilEntry 1 }
+
+ ctInbUtilDestSlot OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The chassis slot number containing the module to which bytes are
+ transmitted across the INB."
+ ::= { ctInbUtilEntry 2 }
+
+ ctInbUtilHiByteCountA OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The high-order 32 bits of the 64-bit entity which represents the number
+ of bytes transferred from the source module to the destination module
+ across INB channel A during the last sampling interval. This 64-bit
+ byte count may be calculated as:
+ ctInbUtilByteCountA = (ctInbUtilHiByteCountA * 2**32) + ctInbUtilLoByteCountA "
+ ::= { ctInbUtilEntry 3 }
+
+ ctInbUtilLoByteCountA OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The low-order 32 bits of the 64-bit entity which represents the number
+ of bytes transferred from the source module to the destination module
+ across INB channel A during the last sampling interval. This 64-bit
+ byte count may be calculated as:
+ ctInbUtilByteCountA = (ctInbUtilHiByteCountA * 2**32) + ctInbUtilLoByteCountA "
+ ::= { ctInbUtilEntry 4 }
+
+ ctInbUtilHiByteCountB OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The high-order 32 bits of the 64-bit entity which represents the number
+ of bytes transferred from the source module to the destination module
+ across INB channel B during the last sampling interval. This 64-bit
+ byte count may be calculated as:
+ ctInbUtilByteCountB = (ctInbUtilHiByteCountB * 2**32) + ctInbUtilLoByteCountB "
+ ::= { ctInbUtilEntry 5 }
+
+ ctInbUtilLoByteCountB OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The low-order 32 bits of the 64-bit entity which represents the number
+ of bytes transferred from the source module to the destination module
+ across INB channel B during the last sampling interval. This 64-bit
+ byte count may be calculated as:
+ ctInbUtilByteCountB = (ctInbUtilHiByteCountB * 2**32) + ctInbUtilLoByteCountB "
+ ::= { ctInbUtilEntry 6 }
+
+ ctInbUtilAbsoluteA OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The percentage of absolute utilization of INB channel A by data transferred
+ from the source module to the destination module during the last sampling
+ interval. This percentage is calculated by dividing ctInbUtilByteCountA
+ (a 64-bit entity which is calculated as specified above) by
+ the theoretical maximum number of bytes that could have traversed INB
+ channel A during the interval. Note that in order to increase precision,
+ the value of this object is the actual percentage multiplied by 100 (that
+ is, to determine the actual percentage, divide the value of this object by
+ 100)."
+ ::= { ctInbUtilEntry 7 }
+
+ ctInbUtilAbsoluteB OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The percentage of absolute utilization of INB channel B by data transferred
+ from the source module to the destination module during the last sampling
+ interval. This percentage is calculated by dividing ctInbUtilByteCountB
+ (a 64-bit entity which is calculated as specified above) by
+ the theoretical maximum number of bytes that could have traversed INB
+ channel B during the interval. Note that in order to increase precision,
+ the value of this object is the actual percentage multiplied by 100 (that
+ is, to determine the actual percentage, divide the value of this object by
+ 100)."
+ ::= { ctInbUtilEntry 8 }
+
+ ctInbUtilAbsoluteTotal OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The percentage of absolute utilization of the total INB by data transferred
+ from the source module to the destination module during the last sampling
+ interval. This percentage is calculated by dividing the sum of
+ ctInbUtilByteCountA and ctInbUtilByteCountB by the theoretical maximum number
+ of bytes that could have traversed both INB channels during the interval.
+ Note that in order to increase precision, the value of this object is the
+ actual percentage multiplied by 100 (that is, to determine the actual
+ percentage, divide the value of this object by 100)."
+ ::= { ctInbUtilEntry 9 }
+
+
+END