summaryrefslogtreecommitdiff
path: root/MIBS/enlogic
diff options
context:
space:
mode:
Diffstat (limited to 'MIBS/enlogic')
-rw-r--r--MIBS/enlogic/ENLOGIC-PDU-MIB5191
1 files changed, 5191 insertions, 0 deletions
diff --git a/MIBS/enlogic/ENLOGIC-PDU-MIB b/MIBS/enlogic/ENLOGIC-PDU-MIB
new file mode 100644
index 0000000..dfb3296
--- /dev/null
+++ b/MIBS/enlogic/ENLOGIC-PDU-MIB
@@ -0,0 +1,5191 @@
+ENLOGIC-PDU-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE FROM SNMPv2-SMI
+ enterprises, Integer32, Unsigned32, IpAddress FROM SNMPv2-SMI
+ MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF
+ TEXTUAL-CONVENTION, DisplayString, MacAddress, TruthValue FROM SNMPv2-TC
+ InetAddressType, InetAddress FROM INET-ADDRESS-MIB
+ sysContact, sysName, sysLocation FROM RFC1213-MIB;
+
+enlogic MODULE-IDENTITY
+
+ LAST-UPDATED "201506180000Z" -- June 18, 2015
+
+ ORGANIZATION "Enlogic"
+
+ CONTACT-INFO ""
+
+ DESCRIPTION "This MIB describes the SNMP functions of the Enlogic PDU."
+
+ REVISION "201410280000Z" -- October 28, 2014
+
+ DESCRIPTION "
+ 1. Add Smart Cabinet related MIB nodes.
+ "
+
+ REVISION "201406050000Z" -- June 5, 2014
+
+ DESCRIPTION "
+ 1. Add new trap named espNetworkUp for ES PDU.
+ "
+
+ REVISION "201404300000Z" -- April 30, 2014
+
+ DESCRIPTION "
+ 1. Modify description of MIB node pduInputPhaseStatusCurrentState, pduInputPhaseStatusCurrent, pduInputPhaseStatusVoltage, pduInputPhaseStatusActivePower,
+ pduInputPhaseStatusApparentPower and pduInputPhaseStatusPowerFactor.
+ "
+
+ REVISION "201306050000Z" -- June 5, 2013
+
+ DESCRIPTION "
+ 1. Change node pduExternalSensorStatusAisle to be writable.
+ "
+
+ REVISION "201305310000Z" -- May 31, 2013
+
+ DESCRIPTION "
+ 1. Add MIB node for daisy chain state.
+ "
+
+ REVISION "201303280000Z" -- March 28, 2013
+
+ DESCRIPTION "
+ 1. Add one more attribute for all trap oids indicating pdu idx in case of daisy chain.
+ 2. Add one more MIB node in order to reset network management card
+ "
+
+ REVISION "201303210000Z" -- March 21, 2013
+
+ DESCRIPTION "
+ 1. Add MIB node for external sensor unique identifier.
+ 2. Add MIB node for external sensor readings with higher Pricision.
+ "
+
+ REVISION "201301240000Z" -- January 24, 2013
+
+ DESCRIPTION "
+ 1. change external sensor name doorContact to doorSwitch
+ "
+
+ REVISION "201301060000Z" -- January 6, 2013
+
+ DESCRIPTION "
+ 1. change the enum value definition of external sensor threshold setting
+ 2. Add a new node to enable/disable SSH connection
+ 3. Add one more external sensor unit
+ "
+
+ REVISION "201212280000Z" -- December 28, 2012
+
+ DESCRIPTION "
+ 1. Add one more node to enable/disable sensor
+ "
+
+ REVISION "201209280000Z" -- September 28, 2012
+
+ DESCRIPTION "
+ 1. Added additional indexes.
+
+ "
+ REVISION "201209250000Z" -- September 25, 2012
+
+ DESCRIPTION "
+ 1. Changed descriptions for status readings.
+
+ "
+ REVISION "201209180000Z" -- September 18, 2012
+
+ DESCRIPTION "
+ 1. Changed descriptions for alarm thresholds.
+ 2. Renamed pduOutletMeteredStatusEnergy to pduOutletMeteredStatusResettableEnergy.
+ 3. Added pduUnitConfigOutletPeakPowerReset
+
+ "
+ REVISION "201209130000Z" -- September 13, 2012
+
+ DESCRIPTION "
+ 1. Changed SYNTAX of pduUnitConfigUpperWarningThreshold SEQUENCE to Unsigned32
+ 2. Changed SYNTAX of pduOutletSwitchedStateOnStartup to Integer32
+ 3. Changed SYNTAX of pduServerPingEnabled to TruthValue
+ 4. Added trapsInformationIndex to SEQUENCE of TrapsInformationEntry
+
+ "
+ ::= { enterprises 38446 }
+
+
+pdu OBJECT IDENTIFIER ::= { enlogic 1 }
+pduNamePlate OBJECT IDENTIFIER ::= { pdu 1 }
+pduUnit OBJECT IDENTIFIER ::= { pdu 2 }
+pduInputPhase OBJECT IDENTIFIER ::= { pdu 3 }
+pduCircuitBreaker OBJECT IDENTIFIER ::= { pdu 4 }
+pduOutlet OBJECT IDENTIFIER ::= { pdu 5 }
+pduExternalSensor OBJECT IDENTIFIER ::= { pdu 6 }
+pduServerPing OBJECT IDENTIFIER ::= { pdu 7 }
+pduSmartCabinet OBJECT IDENTIFIER ::= { pdu 8 }
+pduTraps OBJECT IDENTIFIER ::= { pdu 9 }
+
+-- Start pduNamePlate
+
+pduNamePlateTableSize OBJECT-TYPE
+ SYNTAX Integer32 (1..256)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of PDUs"
+ ::= { pduNamePlate 1 }
+
+-- pduNamePlateTable
+pduNamePlateTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PduNamePlateEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of PDU nameplate data"
+ ::= { pduNamePlate 2 }
+
+pduNamePlateEntry OBJECT-TYPE
+ SYNTAX PduNamePlateEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Nameplate data from the PDU being queried. The numbers of entries equals the value of pduNamePlateTableSize."
+ INDEX { pduNamePlateIndex }
+ ::= { pduNamePlateTable 1 }
+
+PduNamePlateEntry ::= SEQUENCE {
+ pduNamePlateIndex
+ Integer32,
+ pduNamePlateName
+ DisplayString,
+ pduNamePlateLocation
+ DisplayString,
+ pduNamePlateInetAddressType
+ InetAddressType,
+ pduNamePlateIPAddress
+ InetAddress,
+ pduNamePlateInetNetMask
+ InetAddress,
+ pduNamePlateInetGateway
+ InetAddress,
+ pduNamePlateMACAddress
+ MacAddress,
+ pduNamePlateUTCTimeOffset
+ DisplayString,
+ pduNamePlateModelNumber
+ DisplayString,
+ pduNamePlateSerialNumber
+ DisplayString,
+ pduNamePlateDateofManufacture
+ DisplayString,
+ pduNamePlateFirmwareVersion
+ DisplayString,
+ pduNamePlateFirmwareVersionTimeStamp
+ DisplayString,
+ pduNamePlateType
+ INTEGER
+ }
+
+pduNamePlateIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..256)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The index of the PDU nameplate table entry"
+ ::= { pduNamePlateEntry 1 }
+
+pduNamePlateName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A user-defined string identifying the PDU"
+ ::= { pduNamePlateEntry 2 }
+
+pduNamePlateLocation OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A user-defined string identifying the location of PDU"
+ ::= { pduNamePlateEntry 3 }
+
+pduNamePlateInetAddressType OBJECT-TYPE
+ SYNTAX InetAddressType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The type of address format"
+ ::= { pduNamePlateEntry 4 }
+
+pduNamePlateIPAddress OBJECT-TYPE
+ SYNTAX InetAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current IP address. A value of 0.0.0.0 indicates an error or an unset option"
+ ::= { pduNamePlateEntry 5 }
+
+pduNamePlateInetNetMask OBJECT-TYPE
+ SYNTAX InetAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current netmask. A value of 0.0.0.0 indiates an error or an unset option"
+ ::= { pduNamePlateEntry 6 }
+
+pduNamePlateInetGateway OBJECT-TYPE
+ SYNTAX InetAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current gateway. A value of 0.0.0.0 indicates an error or an unset option"
+ ::= { pduNamePlateEntry 7 }
+
+pduNamePlateMACAddress OBJECT-TYPE
+ SYNTAX MacAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The assigned MAC address for the PDU"
+ ::= { pduNamePlateEntry 8 }
+
+pduNamePlateUTCTimeOffset OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The difference in hours and minutes from Coordinated Universal
+ Time(UTC) for the time used in a particular time zone"
+ ::= { pduNamePlateEntry 9 }
+
+pduNamePlateModelNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The PDU model number"
+ ::= { pduNamePlateEntry 10 }
+
+pduNamePlateSerialNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The PDU serial number"
+ ::= { pduNamePlateEntry 11 }
+
+pduNamePlateDateofManufacture OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The date the PDU was manufactured in mm/dd/yyyy format"
+ ::= { pduNamePlateEntry 12 }
+
+pduNamePlateFirmwareVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The PDU firmware version"
+ ::= { pduNamePlateEntry 13 }
+
+pduNamePlateFirmwareVersionTimeStamp OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Timestamp of when the PDU firmware was last updated"
+ ::= { pduNamePlateEntry 14 }
+
+pduNamePlateType OBJECT-TYPE
+ SYNTAX INTEGER {
+ pdu (0),
+ inlineMeter (1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The type of Unit, PDU or Inline Meter"
+ ::= { pduNamePlateEntry 15 }
+
+
+-- Start pduUnit
+
+pduUnitTableSize OBJECT-TYPE
+ SYNTAX Integer32 (1..256)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of units."
+ ::= { pduUnit 1 }
+
+pduUnitConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PduUnitConfigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of PDU configuration data"
+ ::= { pduUnit 2 }
+
+pduUnitConfigEntry OBJECT-TYPE
+ SYNTAX PduUnitConfigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Configuration data from the PDU being queried. The number of entries equals the value of pduUnitTableSize"
+ INDEX { pduUnitConfigIndex }
+ ::= { pduUnitConfigTable 1 }
+
+PduUnitConfigEntry ::= SEQUENCE {
+ pduUnitConfigIndex
+ Integer32,
+ pduUnitConfigName
+ DisplayString,
+ pduUnitConfigLocation
+ DisplayString,
+ pduUnitConfigDisplayOrientation
+ INTEGER,
+ pduUnitConfigColdstartDelay
+ Unsigned32,
+ pduUnitConfigGlobalOutletStateOnStartup
+ INTEGER,
+ pduUnitConfigLowerCriticalThreshold
+ Unsigned32,
+ pduUnitConfigLowerWarningThreshold
+ Unsigned32,
+ pduUnitConfigUpperCriticalThreshold
+ Unsigned32,
+ pduUnitConfigUpperWarningThreshold
+ Unsigned32,
+ pduUnitConfigAlarmResetThreshold
+ Unsigned32,
+ pduUnitConfigAlarmStateChangeDelay
+ Unsigned32,
+ pduUnitConfigEnabledThresholds
+ BITS,
+ pduUnitConfigPeakPowerReset
+ INTEGER,
+ pduUnitConfigEnergyReset
+ INTEGER,
+ pduUnitConfigOutletPeakPowerReset
+ INTEGER,
+ pduUnitConfigOutletEnergyReset
+ INTEGER,
+ pduUnitConfigUsb
+ INTEGER,
+ pduUnitConfigSsh
+ INTEGER,
+ pduUnitConfigResetNetworkManagementCard
+ INTEGER,
+ pduUnitConfigDaisyChainState
+ INTEGER
+ }
+
+pduUnitConfigIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..256)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The index of the PDU Unit Config Entry"
+ ::= { pduUnitConfigEntry 1 }
+
+pduUnitConfigName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A user-defined string identifying the PDU"
+ ::= { pduUnitConfigEntry 2 }
+
+pduUnitConfigLocation OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A user-defined string identifying the location of the PDU"
+ ::= { pduUnitConfigEntry 3 }
+
+pduUnitConfigDisplayOrientation OBJECT-TYPE
+ SYNTAX INTEGER {
+ displayNormal (1),
+ displayReverse (2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Indicates the intended physical orientation of the oLED display
+ displayNormal (1) indicates normal orientation.
+ displayReverse (2) indicates upside down orientation"
+ ::= { pduUnitConfigEntry 4 }
+
+pduUnitConfigColdstartDelay OBJECT-TYPE
+ SYNTAX Unsigned32 (0..3600)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The amount of time, specified in seconds, between when power
+ is provided to the PDU and when the PDU start providing basic master
+ power to the outlets"
+ ::= { pduUnitConfigEntry 5 }
+
+pduUnitConfigGlobalOutletStateOnStartup OBJECT-TYPE
+ SYNTAX INTEGER {
+ off (0),
+ on (1),
+ lastKnownState (2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The outlet state on device startup; applies to all outlets
+ unless overridden at the outlet level"
+ ::= { pduUnitConfigEntry 6 }
+
+pduUnitConfigLowerCriticalThreshold OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "User-defined lower critical unit active power alarm threshold measured in Watts"
+ ::= { pduUnitConfigEntry 7 }
+
+pduUnitConfigLowerWarningThreshold OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "User-defined lower non-critical (warning) unit active power alarm threshold measured in Watts"
+ ::= { pduUnitConfigEntry 8 }
+
+pduUnitConfigUpperCriticalThreshold OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "User-defined upper critical unit active power alarm threshold measured in Watts"
+ ::= { pduUnitConfigEntry 9 }
+
+pduUnitConfigUpperWarningThreshold OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "User-defined upper non-critical (warning) unit active power alarm threshold measured in Watts"
+ ::= { pduUnitConfigEntry 10 }
+
+pduUnitConfigAlarmResetThreshold OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The hysteresis used for deassertions in Watts"
+ ::= { pduUnitConfigEntry 11 }
+
+pduUnitConfigAlarmStateChangeDelay OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The delay measured in samples before a state is asserted. If the value is zero, then the state is asserted as soon as it is detected; if it is non-zero, say n, then the assertion condition must exist for n+1 consecutive samples before the corresponding assertion event is reported."
+ ::= { pduUnitConfigEntry 12 }
+
+pduUnitConfigEnabledThresholds OBJECT-TYPE
+ SYNTAX BITS {
+ lowerCritical (0),
+ lowerWarning (1),
+ upperWarning (2),
+ upperCritical (3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A bit string indicating which alarm thresholds are enabled"
+ ::= { pduUnitConfigEntry 13 }
+
+pduUnitConfigPeakPowerReset OBJECT-TYPE
+ SYNTAX INTEGER {
+ noOperation (1),
+ reset (2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Setting this OID to reset (2) will cause the existing peak power value
+ to be replaced by the current load power value. Getting this OID will
+ do nothing and return the noOperation(1) value. "
+ ::= { pduUnitConfigEntry 14 }
+
+pduUnitConfigEnergyReset OBJECT-TYPE
+ SYNTAX INTEGER {
+ noOperation (1),
+ reset (2),
+ notSupported (3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Setting this OID to reset (2) will cause the device energy meter value
+ to be reset to zero. Getting this OID in models that support this
+ feature will do nothing and return the noOperation(1) value. Models
+ that do not support this feature will respond to this OID with a
+ value of notSupported (3). Attempts to set this OID in these models will fail. "
+ ::= { pduUnitConfigEntry 15 }
+
+pduUnitConfigOutletPeakPowerReset OBJECT-TYPE
+ SYNTAX INTEGER {
+ noOperation (1),
+ reset (2),
+ notSupported (3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Setting this OID to reset (2) will cause the outlet peak power meter value
+ to be reset to zero. Getting this OID in models that support this
+ feature will do nothing and return the noOperation(1) value. Models
+ that do not support this feature will respond to this OID with a
+ value of notSupported (3). Attempts to set this OID in these models will fail. "
+ ::= { pduUnitConfigEntry 16 }
+
+pduUnitConfigOutletEnergyReset OBJECT-TYPE
+ SYNTAX INTEGER {
+ noOperation (1),
+ reset (2),
+ notSupported (3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Setting this OID to reset (2) will cause the outlet energy meter value
+ to be reset to zero. Getting this OID in models that support this
+ feature will do nothing and return the noOperation(1) value. Models
+ that do not support this feature will respond to this OID with a
+ value of notSupported (3). Attempts to set this OID in these models will fail. "
+ ::= { pduUnitConfigEntry 17 }
+
+pduUnitConfigUsb OBJECT-TYPE
+ SYNTAX INTEGER {
+ off (0),
+ on (1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Setting this OID to off(0) will disable the USB port. Setting this OID to on(1) will enable the USB port."
+ ::= { pduUnitConfigEntry 18 }
+
+pduUnitConfigSsh OBJECT-TYPE
+ SYNTAX INTEGER {
+ off (0),
+ on (1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Setting this OID to off(0) will disable the SSH connection. Setting this OID to on(1) will enable the SSH connection."
+ ::= { pduUnitConfigEntry 19 }
+
+pduUnitConfigResetNetworkManagementCard OBJECT-TYPE
+ SYNTAX INTEGER {
+ noOperation (0),
+ reset (1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Getting this OID will return noOperation(0). Setting this OID to reset(1) will reset NMC."
+ ::= { pduUnitConfigEntry 20 }
+
+pduUnitConfigDaisyChainState OBJECT-TYPE
+ SYNTAX INTEGER {
+ daisychain (0)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Setting this OID to daisychain(0) will enable daisychain mode."
+ ::= { pduUnitConfigEntry 21 }
+
+pduUnitPropertiesTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PduUnitPropertiesEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of PDU properties"
+ ::= { pduUnit 3 }
+
+pduUnitPropertiesEntry OBJECT-TYPE
+ SYNTAX PduUnitPropertiesEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A unit properties entry containing objects for a particular unit."
+ INDEX { pduUnitPropertiesIndex }
+ ::= { pduUnitPropertiesTable 1 }
+
+PduUnitPropertiesEntry ::= SEQUENCE {
+ pduUnitPropertiesIndex
+ Integer32,
+ pduUnitPropertiesName
+ DisplayString,
+ pduUnitPropertiesOutletCount
+ Integer32,
+ pduUnitPropertiesSwitchedOutletCount
+ Integer32,
+ pduUnitPropertiesMeteredOutletCount
+ Integer32,
+ pduUnitPropertiesInputPhaseCount
+ Integer32,
+ pduUnitPropertiesCircuitBreakerCount
+ Integer32,
+ pduUnitPropertiesMaxExternalSensorCount
+ Integer32,
+ pduUnitPropertiesConnExternalSensorCount
+ Integer32,
+ pduUnitPropertiesRatedVoltage
+ DisplayString,
+ pduUnitPropertiesRatedMaxCurrent
+ DisplayString,
+ pduUnitPropertiesRatedFrequency
+ DisplayString,
+ pduUnitPropertiesRatedPower
+ DisplayString,
+ pduUnitPropertiesOrientation
+ INTEGER,
+ pduUnitPropertiesOutletLayout
+ INTEGER,
+ pduUnitPropertiesDaisyChainMemberType
+ INTEGER,
+ pduUnitPropertiesServerCount
+ Integer32
+ }
+
+pduUnitPropertiesIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..256)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The index of the PDU properties table entry"
+ ::= { pduUnitPropertiesEntry 1 }
+
+pduUnitPropertiesName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A user-defined string identifying the PDU"
+ ::= { pduUnitPropertiesEntry 2 }
+
+pduUnitPropertiesOutletCount OBJECT-TYPE
+ SYNTAX Integer32 (1..256)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of outlets on the PDU"
+ ::= { pduUnitPropertiesEntry 3 }
+
+pduUnitPropertiesSwitchedOutletCount OBJECT-TYPE
+ SYNTAX Integer32 (1..256)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of switched outlets on the PDU"
+ ::= { pduUnitPropertiesEntry 4 }
+
+pduUnitPropertiesMeteredOutletCount OBJECT-TYPE
+ SYNTAX Integer32 (1..256)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of metered outlets on the PDU"
+ ::= { pduUnitPropertiesEntry 5 }
+
+pduUnitPropertiesInputPhaseCount OBJECT-TYPE
+ SYNTAX Integer32 (1..256)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of phases on the PDU"
+ ::= { pduUnitPropertiesEntry 6 }
+
+pduUnitPropertiesCircuitBreakerCount OBJECT-TYPE
+ SYNTAX Integer32 (0..255)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of circuit breaker on the PDU"
+ ::= { pduUnitPropertiesEntry 7 }
+
+pduUnitPropertiesMaxExternalSensorCount OBJECT-TYPE
+ SYNTAX Integer32 (0..255)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The maximum number of external sensors that can be connected to the PDU"
+ ::= { pduUnitPropertiesEntry 8 }
+
+pduUnitPropertiesConnExternalSensorCount OBJECT-TYPE
+ SYNTAX Integer32 (0..255)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current number of external sensors connected to the PDU"
+ ::= { pduUnitPropertiesEntry 9 }
+
+pduUnitPropertiesRatedVoltage OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The PDU voltage rating in Volts"
+ ::= { pduUnitPropertiesEntry 10 }
+
+pduUnitPropertiesRatedMaxCurrent OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The PDU current rating in Amps"
+ ::= { pduUnitPropertiesEntry 11 }
+
+pduUnitPropertiesRatedFrequency OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The PDU frequency rating in Hz"
+ ::= { pduUnitPropertiesEntry 12 }
+
+pduUnitPropertiesRatedPower OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The PDU VA (VoltAmps) rating."
+ ::= { pduUnitPropertiesEntry 13 }
+
+pduUnitPropertiesOrientation OBJECT-TYPE
+ SYNTAX INTEGER {
+ horizontal (1),
+ vertical (2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The PDU orientation "
+ ::= { pduUnitPropertiesEntry 14 }
+
+pduUnitPropertiesOutletLayout OBJECT-TYPE
+ SYNTAX INTEGER {
+ seqPhaseToNuetral (1),
+ seqPhaseToPhase (2),
+ seqPhToNeu21PhToPh (3),
+ seqPhToPhGrouped (4),
+ seqPhToNGrouped (5),
+ seqPToN1516PToPGrouped (6),
+ seqPhToPh2xGrouped (7),
+ seqPhToN2xGrouped (8),
+ seqNotApplicable (9)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The outlet layout for the PDU. Getting this OID will return outlet layout for the device.
+ seqPhaseToNeutral(1) indicates outlet layout as follows:
+ 1:1-N,2:2-N,3:3-N,4:1-N,5:2-N,...
+ seqPhaseToPhase(2) indicates outlet layout as follows:
+ 1:1-2,2:2-3,3:3-1,4:1-2,5:2-3,...
+ seqPhToNeu21PhToPh(3) indicates outlet layout as follows:
+ 1:1-N,2:2-N...21:3-N,22:1-2,23:2-3,24:3-1,...
+ seqPhToPhGrouped(4) indicates outlet layout as follows:
+ This unit has 3 outlet groups. Group 1:1-2, Group 2:2-3, Group 3:3-1.
+ seqPhToNGrouped(5) indicates outlet layout as follows:
+ This unit has 3 outlet groups. Group 1:1-N, Group 2:2-N, Group 3:3-N.
+ seqPToN1516PToPGrouped(6) indicates outlet layout as follows:
+ This unit has 4 outlet groups. Group 1 (Outlets 1-14):1-2,
+ Group 2 (Outlets 15-16):1-N, Group 3:2-3, Group 4:3-1.
+ seqPhToPh2xGrouped(7) indicates outlet layout as follows:
+ This unit has 6 outlet groups. Group 1:1-2, Group 2:1-2, Group 3:2-3,
+ Group 4:2-3, Group 5:3-1, Group 6:3-1.
+ seqPhToN2xGrouped(8) indicates outlet layout as follows:
+ This unit has 6 outlet groups. Group 1:1-N, Group 2:1-N, Group 3:2-N,
+ Group 4:2-N, Group 5:3-N, Group 6:3-N.
+ seqNotApplicable(9):"
+ ::= { pduUnitPropertiesEntry 15 }
+
+pduUnitPropertiesDaisyChainMemberType OBJECT-TYPE
+ SYNTAX INTEGER {
+ standalone (1),
+ parent (2),
+ child (3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The daisy-chain member type"
+ ::= { pduUnitPropertiesEntry 16 }
+
+pduUnitPropertiesServerCount OBJECT-TYPE
+ SYNTAX Integer32 (0..255)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of servers"
+ ::= { pduUnitPropertiesEntry 17 }
+
+pduUnitStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PduUnitStatusEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of PDU status information"
+ ::= { pduUnit 4 }
+
+pduUnitStatusEntry OBJECT-TYPE
+ SYNTAX PduUnitStatusEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Status information from the PDU being queried"
+ INDEX { pduUnitStatusIndex }
+ ::= { pduUnitStatusTable 1 }
+
+PduUnitStatusEntry ::= SEQUENCE {
+ pduUnitStatusIndex
+ Integer32,
+ pduUnitStatusName
+ DisplayString,
+ pduUnitStatusLoadState
+ INTEGER,
+ pduUnitStatusActivePower
+ Integer32,
+ pduUnitStatusApparentPower
+ Integer32,
+ pduUnitStatusPeakPower
+ Integer32,
+ pduUnitStatusPeakPowerTimestamp
+ DisplayString,
+ pduUnitStatusPeakPowerStartTime
+ DisplayString,
+ pduUnitStatusEnergy
+ Integer32,
+ pduUnitStatusResettableEnergy
+ Integer32,
+ pduUnitStatusEnergyStartTime
+ DisplayString,
+ pduUnitStatusOutletsEnergyStartTime
+ DisplayString
+ }
+
+pduUnitStatusIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..256)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The index of the PDU status table entry"
+ ::= { pduUnitStatusEntry 1 }
+
+pduUnitStatusName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A user-defined string identifying the PDU"
+ ::= { pduUnitStatusEntry 2 }
+
+pduUnitStatusLoadState OBJECT-TYPE
+ SYNTAX INTEGER {
+ upperCritical (1),
+ upperWarning (2),
+ lowerWarning (3),
+ lowerCritical (4),
+ normal (5)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Returns the present load status of the PDU based on Active Power."
+ ::= { pduUnitStatusEntry 3 }
+
+pduUnitStatusActivePower OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Returns power consumption, in Watts(W),
+ of the PDU being queried."
+ ::= { pduUnitStatusEntry 4 }
+
+pduUnitStatusApparentPower OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Returns power consumption, in Volt-Amps(VA)
+ of the PDU load being queried."
+ ::= { pduUnitStatusEntry 5 }
+
+pduUnitStatusPeakPower OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Returns peak power consumption, in Watts(W),
+ of the PDU being queried."
+ ::= { pduUnitStatusEntry 6 }
+
+pduUnitStatusPeakPowerTimestamp OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the date and time that peak power consumption occurred"
+ ::= { pduUnitStatusEntry 7 }
+
+pduUnitStatusPeakPowerStartTime OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the date and time of the last device peak power reset"
+ ::= { pduUnitStatusEntry 8 }
+
+pduUnitStatusEnergy OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Returns total energy consumed, in tenths of Kilowatt-Hours(kWh), of the PDU over its lifetime."
+ ::= { pduUnitStatusEntry 9 }
+
+pduUnitStatusResettableEnergy OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A user resettable energy meter measuring PDU energy consumption
+ in tenths of kilowatt-hours(kWh)."
+ ::= { pduUnitStatusEntry 10 }
+
+pduUnitStatusEnergyStartTime OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the date and time of the last device energy meter reset"
+ ::= { pduUnitStatusEntry 11 }
+
+pduUnitStatusOutletsEnergyStartTime OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the date and time of the last outlets energy meter reset"
+ ::= { pduUnitStatusEntry 12 }
+
+-- Start pduInputPhase
+pduInputPhaseTableSize OBJECT-TYPE
+ SYNTAX Integer32 (1..256)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of PDU Input Phases "
+ ::= { pduInputPhase 1 }
+
+pduInputPhaseConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PduInputPhaseConfigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of PDU Input Phase configuration data"
+ ::= { pduInputPhase 2 }
+
+pduInputPhaseConfigEntry OBJECT-TYPE
+ SYNTAX PduInputPhaseConfigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An input phase entry containing objects for a particular input phase."
+ INDEX { pduUnitConfigIndex, pduInputPhaseConfigIndex }
+ ::= { pduInputPhaseConfigTable 1 }
+
+PduInputPhaseConfigEntry ::= SEQUENCE {
+ pduInputPhaseConfigIndex
+ Integer32,
+ pduInputPhaseConfigCount
+ Integer32,
+ pduInputPhaseConfigOverloadRestriction
+ INTEGER,
+ pduInputPhaseConfigCurrentLowerCriticalThreshold
+ Unsigned32,
+ pduInputPhaseConfigCurrentLowerWarningThreshold
+ Unsigned32,
+ pduInputPhaseConfigCurrentUpperCriticalThreshold
+ Unsigned32,
+ pduInputPhaseConfigCurrentUpperWarningThreshold
+ Unsigned32,
+ pduInputPhaseConfigVoltageLowerCriticalThreshold
+ Unsigned32,
+ pduInputPhaseConfigVoltageLowerWarningThreshold
+ Unsigned32,
+ pduInputPhaseConfigVoltageUpperCriticalThreshold
+ Unsigned32,
+ pduInputPhaseConfigVoltageUpperWarningThreshold
+ Unsigned32,
+ pduInputPhaseConfigCurrentAlarmResetThreshold
+ Unsigned32,
+ pduInputPhaseConfigCurrentAlarmStateChangeDelay
+ Integer32,
+ pduInputPhaseConfigCurrentEnabledThresholds
+ BITS,
+ pduInputPhaseConfigVoltageAlarmResetThreshold
+ Unsigned32,
+ pduInputPhaseConfigVoltageAlarmStateChangeDelay
+ Integer32,
+ pduInputPhaseConfigVoltageEnabledThresholds
+ BITS
+ }
+
+pduInputPhaseConfigIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..256)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The index of the PDU Input Phase configuration table entry"
+ ::= { pduInputPhaseConfigEntry 1 }
+
+pduInputPhaseConfigCount OBJECT-TYPE
+ SYNTAX Integer32 (1..256)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of Input Phases"
+ ::= { pduInputPhaseConfigEntry 2 }
+
+pduInputPhaseConfigOverloadRestriction OBJECT-TYPE
+ SYNTAX INTEGER {
+ alwaysAllowTurnOn (1),
+ restrictOnUpperWarning (2),
+ restrictOnUpperCritical (3),
+ notSupported (4)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This OID controls the behavior of a Switched PDU Input Phase when an
+ overload condition is possible and additional outlets are requested
+ to be turned on. Setting this OID to alwaysAllowTurnON (1) will always
+ allow the outlets on the corresponding Input Phase to turn on. Setting
+ this OID to restrictOnUpperWarning (2) will not allow outlets on the
+ corresponding Input Phase to turn on if the
+ pduInputPhaseConfigUpperWarningThreshold OID is exceeded. Setting
+ this OID to restrictOnUpperCritical (3) will not allow outlets on
+ the corresponding Input Phase to turn on if the
+ pduInputPhaseConfigUpperCriticalThreshold OID is exceeded. Models
+ that do not support this feature will respond to this OID with a
+ value of notSupported (4). Attempts to set this OID in these
+ models will fail. "
+ ::= { pduInputPhaseConfigEntry 3 }
+
+pduInputPhaseConfigCurrentLowerCriticalThreshold OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "User-defined lower critical input phase current alarm threshold in hundredths of Amps(A)."
+ ::= { pduInputPhaseConfigEntry 4 }
+
+pduInputPhaseConfigCurrentLowerWarningThreshold OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "User-defined lower non-critical (warning) input phase current alarm threshold in hundredths of Amps(A)."
+ ::= { pduInputPhaseConfigEntry 5 }
+
+pduInputPhaseConfigCurrentUpperCriticalThreshold OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "User-defined upper critical input phase current alarm threshold in hundredths of Amps(A)."
+ ::= { pduInputPhaseConfigEntry 6 }
+
+pduInputPhaseConfigCurrentUpperWarningThreshold OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "User-defined upper non-critical (warning) input phase current alarm threshold in hundredths of Amps(A)."
+ ::= { pduInputPhaseConfigEntry 7 }
+
+pduInputPhaseConfigVoltageLowerCriticalThreshold OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "User-defined lower critical input phase voltage alarm threshold in Volts(V)."
+ ::= { pduInputPhaseConfigEntry 8 }
+
+pduInputPhaseConfigVoltageLowerWarningThreshold OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "User-defined lower non-critical (warning) input phase voltage alarm threshold in Volts(V)."
+ ::= { pduInputPhaseConfigEntry 9 }
+
+pduInputPhaseConfigVoltageUpperCriticalThreshold OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "User-defined upper critical input phase voltage alarm threshold in Volts(V)."
+ ::= { pduInputPhaseConfigEntry 10 }
+
+pduInputPhaseConfigVoltageUpperWarningThreshold OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "User-defined upper non-critical (warning) input phase voltage alarm threshold in Volts(V)."
+ ::= { pduInputPhaseConfigEntry 11 }
+
+pduInputPhaseConfigCurrentAlarmResetThreshold OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The hysteresis used for current alarm deassertions in hundredths of Amps(A)."
+ ::= { pduInputPhaseConfigEntry 12 }
+
+pduInputPhaseConfigCurrentAlarmStateChangeDelay OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The delay measured in samples before a current state is asserted. If the
+ value is zero, then the state is asserted as soon as it is
+ detected; if it is non-zero, say n, then the assertion condition
+ must exist for n+1 consecutive samples before the corresponding
+ assertion event is reported. "
+ ::= { pduInputPhaseConfigEntry 13 }
+
+pduInputPhaseConfigCurrentEnabledThresholds OBJECT-TYPE
+ SYNTAX BITS {
+ lowerCritical (0),
+ lowerWarning (1),
+ upperWarning (2),
+ upperCritical (3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A bit string indicating which current alarm thresholds are enabled."
+ ::= { pduInputPhaseConfigEntry 14 }
+
+pduInputPhaseConfigVoltageAlarmResetThreshold OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The hysteresis used for voltage alarm deassertions in Volts(V)."
+ ::= { pduInputPhaseConfigEntry 15 }
+
+pduInputPhaseConfigVoltageAlarmStateChangeDelay OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The delay measured in samples before a voltage state is asserted. If the
+ value is zero, then the state is asserted as soon as it is
+ detected; if it is non-zero, say n, then the assertion condition
+ must exist for n+1 consecutive samples before the corresponding
+ assertion event is reported. "
+ ::= { pduInputPhaseConfigEntry 16 }
+
+pduInputPhaseConfigVoltageEnabledThresholds OBJECT-TYPE
+ SYNTAX BITS {
+ lowerCritical (0),
+ lowerWarning (1),
+ upperWarning (2),
+ upperCritical (3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A bit string indicating which voltage alarm thresholds are enabled."
+ ::= { pduInputPhaseConfigEntry 17 }
+
+pduInputPhasePropertiesTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PduInputPhasePropertiesEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of PDU Input Phase properties"
+ ::= { pduInputPhase 3 }
+
+pduInputPhasePropertiesEntry OBJECT-TYPE
+ SYNTAX PduInputPhasePropertiesEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An input phase properties entry containing objects for a particular input phase."
+ INDEX { pduUnitPropertiesIndex, pduInputPhasePropertiesIndex }
+ ::= { pduInputPhasePropertiesTable 1 }
+
+PduInputPhasePropertiesEntry ::= SEQUENCE {
+ pduInputPhasePropertiesIndex
+ Integer32,
+ pduInputPhasePropertiesCount
+ Integer32
+ }
+
+pduInputPhasePropertiesIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..256)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The index of the PDU Input Phase status entry"
+ ::= { pduInputPhasePropertiesEntry 1 }
+
+pduInputPhasePropertiesCount OBJECT-TYPE
+ SYNTAX Integer32 (1..256)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The numeric Input Phase ID"
+ ::= { pduInputPhasePropertiesEntry 2 }
+
+pduInputPhaseStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PduInputPhaseStatusEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of PDU Input Phase status data"
+ ::= { pduInputPhase 4 }
+
+pduInputPhaseStatusEntry OBJECT-TYPE
+ SYNTAX PduInputPhaseStatusEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An input phase status entry containing objects for a particular input phase."
+ INDEX { pduUnitStatusIndex, pduInputPhaseStatusIndex }
+ ::= { pduInputPhaseStatusTable 1 }
+
+PduInputPhaseStatusEntry ::= SEQUENCE {
+ pduInputPhaseStatusIndex
+ Integer32,
+ pduInputPhaseStatusCount
+ Integer32,
+ pduInputPhaseStatusCurrentState
+ INTEGER,
+ pduInputPhaseStatusVoltageState
+ INTEGER,
+ pduInputPhaseStatusCurrent
+ Integer32,
+ pduInputPhaseStatusVoltage
+ Integer32,
+ pduInputPhaseStatusActivePower
+ Integer32,
+ pduInputPhaseStatusApparentPower
+ Integer32,
+ pduInputPhaseStatusPowerFactor
+ Integer32
+ }
+
+pduInputPhaseStatusIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..256)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The index of the PDU Input Phase status entry"
+ ::= { pduInputPhaseStatusEntry 1 }
+
+pduInputPhaseStatusCount OBJECT-TYPE
+ SYNTAX Integer32 (1..256)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The numeric Input Phase ID"
+ ::= { pduInputPhaseStatusEntry 2 }
+
+pduInputPhaseStatusCurrentState OBJECT-TYPE
+ SYNTAX INTEGER {
+ upperCritical (1),
+ upperWarning (2),
+ lowerWarning (3),
+ lowerCritical (4),
+ normal (5)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the present current status of the PDU Phase in case of Y connection or PDU Line in case of Delta conneciton."
+ ::= { pduInputPhaseStatusEntry 3 }
+
+pduInputPhaseStatusVoltageState OBJECT-TYPE
+ SYNTAX INTEGER {
+ upperCritical (1),
+ upperWarning (2),
+ lowerWarning (3),
+ lowerCritical (4),
+ normal (5)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the present voltage status of the PDU Input Phase being queried"
+ ::= { pduInputPhaseStatusEntry 4 }
+
+pduInputPhaseStatusCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Returns the current draw, in hundredths of Amps(A), of the load on the
+ PDU Phase/Line being queried. Nodes with
+ pduInputPhaseStatusIndex from 1 to 3 indicate Y connection Phase values or Delta connection Line values,
+ and nodes with pduInputPhaseStatusIndex from 4 to 6 indicate Delta connection Phase values.
+ "
+ ::= { pduInputPhaseStatusEntry 5 }
+
+pduInputPhaseStatusVoltage OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Returns the voltage, in Volts(V), of the PDU Phase/Line being queried.
+ Nodes with pduInputPhaseStatusIndex from 1 to 3 indicate Y connection Phase values or Delta connection Line values,
+ and nodes with pduInputPhaseStatusIndex from 4 to 6 indicate Delta connection Phase values.
+ "
+ ::= { pduInputPhaseStatusEntry 6 }
+
+pduInputPhaseStatusActivePower OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Returns power consumption, in Watts(W), consumed on the PDU Phase/Line
+ being queried. Nodes with pduInputPhaseStatusIndex from 1 to 3 indicate Y connection
+ Phase values or Delta connection Line values, and nodes with
+ pduInputPhaseStatusIndex from 4 to 6 indicate Delta connection Phase values.
+ "
+ ::= { pduInputPhaseStatusEntry 7 }
+
+pduInputPhaseStatusApparentPower OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Returns power consumption, in Volt-Amps(VA), of the PDU Phase/Line being queried.
+ Nodes with pduInputPhaseStatusIndex from 1 to 3 indicate Y connection Phase values or Delta connection Line values,
+ and nodes with pduInputPhaseStatusIndex from 4 to 6 indicate Delta connection Phase values.
+ "
+ ::= { pduInputPhaseStatusEntry 8 }
+
+pduInputPhaseStatusPowerFactor OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Returns the ratio of active to apparent power of the PDU Phase/Line being queried.
+ Nodes with pduInputPhaseStatusIndex from 1 to 3 indicate Y connection Phase values or Delta connection Line values,
+ and nodes with pduInputPhaseStatusIndex from 4 to 6 indicate Delta connection Phase values.
+ "
+ ::= { pduInputPhaseStatusEntry 9 }
+
+-- Start pduCircuitBreaker
+pduCircuitBreakerTableSize OBJECT-TYPE
+ SYNTAX Integer32 (1..256)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of PDU Circuit Breakers"
+ ::= { pduCircuitBreaker 1 }
+
+pduCircuitBreakerConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PduCircuitBreakerConfigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of PDU Circuit Breaker configuration data"
+ ::= { pduCircuitBreaker 2 }
+
+pduCircuitBreakerConfigEntry OBJECT-TYPE
+ SYNTAX PduCircuitBreakerConfigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A circuit breaker configuration entry containing objects for a particular circuit breaker."
+ INDEX { pduUnitConfigIndex, pduCircuitBreakerConfigIndex }
+ ::= { pduCircuitBreakerConfigTable 1 }
+
+PduCircuitBreakerConfigEntry ::= SEQUENCE {
+ pduCircuitBreakerConfigIndex
+ Integer32,
+ pduCircuitBreakerConfigCount
+ Integer32,
+ pduCircuitBreakerName
+ DisplayString,
+ pduCircuitBreakerConfigOverloadRestriction
+ INTEGER,
+ pduCircuitBreakerConfigLowerCriticalThreshold
+ Unsigned32,
+ pduCircuitBreakerConfigLowerWarningThreshold
+ Unsigned32,
+ pduCircuitBreakerConfigUpperCriticalThreshold
+ Unsigned32,
+ pduCircuitBreakerConfigUpperWarningThreshold
+ Unsigned32,
+ pduCircuitBreakerConfigAlarmResetThreshold
+ Unsigned32,
+ pduCircuitBreakerConfigAlarmStateChangeDelay
+ Unsigned32,
+ pduCircuitBreakerConfigEnabledThresholds
+ BITS
+ }
+
+pduCircuitBreakerConfigIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..256)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The index of the PDU Circuit Breaker configuration table entry"
+ ::= { pduCircuitBreakerConfigEntry 1 }
+
+pduCircuitBreakerConfigCount OBJECT-TYPE
+ SYNTAX Integer32 (0..255)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of circuit breakers on the PDU"
+ ::= { pduCircuitBreakerConfigEntry 2 }
+
+pduCircuitBreakerName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The label of the circuit breaker"
+ ::= { pduCircuitBreakerConfigEntry 3 }
+
+pduCircuitBreakerConfigOverloadRestriction OBJECT-TYPE
+ SYNTAX INTEGER {
+ alwaysAllowTurnOn (1),
+ restrictOnUpperWarning (2),
+ restrictOnUpperCritical (3),
+ notSupported (4)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This OID controls the behavior of a Switched PDU Circuit
+ Breaker when an overload condition is possible and additional
+ outlets are requested to be turned on. Setting this OID to
+ alwaysAllowTurnON (1) will always allow the outlets on the
+ corresponding Circuit Breaker to turn on. Setting this OID
+ to restrictOnUpperWarning (2) will not allow outlets on the
+ corresponding Circuit Breaker to turn on if the
+ pduCircuitBreakerConfigUpperWarningThreshold OID is exceeded.
+ Setting this OID to restrictOnUpperCritical (3) will not
+ allow outlets on the corresponding Circuit Breaker to turn
+ on if the pduCircuitBreakerConfigUpperCriticalThreshold OID
+ is exceeded. Models that do not support this feature will
+ respond to this OID with a value of notSupported (4).
+ Attempts to set this OID in these models will fail. "
+ ::= { pduCircuitBreakerConfigEntry 4 }
+
+pduCircuitBreakerConfigLowerCriticalThreshold OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "User-defined lower critical circuit breaker current alarm threshold in hundredths of Amps(A)."
+ ::= { pduCircuitBreakerConfigEntry 5 }
+
+pduCircuitBreakerConfigLowerWarningThreshold OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "User-defined lower non-critical (warning) circuit breaker current alarm threshold in hundredths of Amps(A)."
+ ::= { pduCircuitBreakerConfigEntry 6 }
+
+pduCircuitBreakerConfigUpperCriticalThreshold OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "User-defined upper critical circuit breaker current alarm threshold in hundredths of Amps(A)."
+ ::= { pduCircuitBreakerConfigEntry 7 }
+
+pduCircuitBreakerConfigUpperWarningThreshold OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "User-defined upper non-critical (warning) circuit breaker current alarm threshold in hundredths of Amps(A)."
+ ::= { pduCircuitBreakerConfigEntry 8 }
+
+pduCircuitBreakerConfigAlarmResetThreshold OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The hysteresis used for deassertions in hundredths of Amps(A)."
+ ::= { pduCircuitBreakerConfigEntry 9 }
+
+pduCircuitBreakerConfigAlarmStateChangeDelay OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The delay measured in samples before a state is asserted.
+ If the value is zero, then the state is asserted as soon
+ as it is detected; if it is non-zero, say n, then the
+ assertion condition must exist for n+1 consecutive samples
+ before the corresponding assertion event is reported."
+ ::= { pduCircuitBreakerConfigEntry 10 }
+
+pduCircuitBreakerConfigEnabledThresholds OBJECT-TYPE
+ SYNTAX BITS {
+ lowerCritical (0),
+ lowerWarning (1),
+ upperWarning (2),
+ upperCritical (3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A bit string indicating which alarm thresholds are enabled."
+ ::= { pduCircuitBreakerConfigEntry 11 }
+
+pduCircuitBreakerPropertiesTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PduCircuitBreakerPropertiesEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of PDU circuit breaker properties"
+ ::= { pduCircuitBreaker 3 }
+
+pduCircuitBreakerPropertiesEntry OBJECT-TYPE
+ SYNTAX PduCircuitBreakerPropertiesEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A circuit breaker properties entry containing objects for a particular circuit breaker."
+ INDEX { pduUnitPropertiesIndex, pduCircuitBreakerPropertiesIndex }
+ ::= { pduCircuitBreakerPropertiesTable 1 }
+
+PduCircuitBreakerPropertiesEntry ::= SEQUENCE {
+ pduCircuitBreakerPropertiesIndex
+ Integer32,
+ pduCircuitBreakerPropertiesCount
+ Integer32,
+ pduCircuitBreakerPropertiesInputLayout
+ INTEGER
+ }
+
+pduCircuitBreakerPropertiesIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..256)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The index of the PDU Circuit Breaker properties table entry"
+ ::= { pduCircuitBreakerPropertiesEntry 1 }
+
+pduCircuitBreakerPropertiesCount OBJECT-TYPE
+ SYNTAX Integer32 (0..255)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Circuit Breakers"
+ ::= { pduCircuitBreakerPropertiesEntry 2 }
+
+pduCircuitBreakerPropertiesInputLayout OBJECT-TYPE
+ SYNTAX INTEGER {
+ seqPhase1ToNeutral (1),
+ seqPhase2ToNeutral (2),
+ seqPhase3ToNeutral (3),
+ seqPhase1ToPhase2 (4),
+ seqPhase2ToPhase3 (5),
+ seqPhase3ToPhase1 (6)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This OID describes the outlet phase connections on
+ the referenced bank as follows:
+ seqPhase1ToNeutral(1) indicates that outlets attached
+ to circuit breaker are connected from Phase 1 to Neutral.
+ seqPhase2ToNeutral(2) indicates that outlets attached
+ to circuit breaker are connected from Phase 2 to Neutral.
+ seqPhase3ToNeutral(3) indicates that outlets attached
+ to circuit breaker are connected from Phase 3 to Neutral.
+ seqPhase1ToPhase2(4) indicates that outlets attached
+ to circuit breaker are connected from Phase 1 to Phase2.
+ seqPhase2ToPhase3(5) indicates that outlets attached
+ to circuit breaker are connected from Phase 2 to Phase3.
+ seqPhase3ToPhase1(6) indicates that outlets attached
+ to circuit breaker are connected from Phase 3 to Phase1. "
+ ::= { pduCircuitBreakerPropertiesEntry 3 }
+
+pduCircuitBreakerStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PduCircuitBreakerStatusEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of PDU circuit breaker status data"
+ ::= { pduCircuitBreaker 4 }
+
+pduCircuitBreakerStatusEntry OBJECT-TYPE
+ SYNTAX PduCircuitBreakerStatusEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A circuit breaker status entry containing objects for a particular circuit breaker."
+ INDEX { pduUnitStatusIndex, pduCircuitBreakerStatusIndex }
+ ::= { pduCircuitBreakerStatusTable 1 }
+
+PduCircuitBreakerStatusEntry ::= SEQUENCE {
+ pduCircuitBreakerStatusIndex
+ Integer32,
+ pduCircuitBreakerStatusCount
+ Integer32,
+ pduCircuitBreakerLabel
+ DisplayString,
+ pduCircuitBreakerStatusLoadState
+ INTEGER,
+ pduCircuitBreakerStatusCurrent
+ Integer32
+ }
+
+pduCircuitBreakerStatusIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..256)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The index of the PDU Circuit Breaker status table entry"
+ ::= { pduCircuitBreakerStatusEntry 1 }
+
+pduCircuitBreakerStatusCount OBJECT-TYPE
+ SYNTAX Integer32 (0..255)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Circuit Breakers"
+ ::= { pduCircuitBreakerStatusEntry 2 }
+
+pduCircuitBreakerLabel OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The label on the PDU identifying the circuit breaker"
+ ::= { pduCircuitBreakerStatusEntry 3 }
+
+pduCircuitBreakerStatusLoadState OBJECT-TYPE
+ SYNTAX INTEGER {
+ upperCritical (1),
+ upperWarning (2),
+ lowerWarning (3),
+ lowerCritical (4),
+ normal (5),
+ off (6)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the present load status of the PDU Circuit
+ Breaker being queried"
+ ::= { pduCircuitBreakerStatusEntry 4 }
+
+pduCircuitBreakerStatusCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Returns the current draw, in hundredths of Amps(A), of the load on
+ the PDU Circuit Breaker being queried."
+ ::= { pduCircuitBreakerStatusEntry 5 }
+
+-- Start pduOutlet
+pduOutletSwitchedTableSize OBJECT-TYPE
+ SYNTAX Integer32 (1..256)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of PDU Outlets"
+ ::= { pduOutlet 1 }
+
+pduOutletSwitchedConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PduOutletSwitchedConfigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of PDU Switched Outlet configuration data"
+ ::= { pduOutlet 2 }
+
+pduOutletSwitchedConfigEntry OBJECT-TYPE
+ SYNTAX PduOutletSwitchedConfigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An outlet configuration entry containing objects for a particular outlet."
+ INDEX { pduUnitConfigIndex, pduOutletSwitchedConfigIndex }
+ ::= { pduOutletSwitchedConfigTable 1 }
+
+PduOutletSwitchedConfigEntry ::= SEQUENCE {
+ pduOutletSwitchedConfigIndex
+ Integer32,
+ pduOutletSwitchedName
+ DisplayString,
+ pduOutletSwitchedStateOnStartup
+ INTEGER,
+ pduOutletSwitchedConfigPowerOnTime
+ Integer32,
+ pduOutletSwitchedConfigPowerOffTime
+ Integer32,
+ pduOutletSwitchedConfigRebootDuration
+ Integer32
+ }
+
+pduOutletSwitchedConfigIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..256)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The index of the PDU Switched Outlet configuration table entry"
+ ::= { pduOutletSwitchedConfigEntry 1 }
+
+pduOutletSwitchedName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The user-defined name for the Switched Outlet"
+ ::= { pduOutletSwitchedConfigEntry 2 }
+
+pduOutletSwitchedStateOnStartup OBJECT-TYPE
+ SYNTAX INTEGER {
+ off (0),
+ on (1),
+ lastKnownState (2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The outlet state on device startup; overrides
+ the global value pduUnitConfigGlobalOutletStateOnStartup."
+ ::= { pduOutletSwitchedConfigEntry 3 }
+
+pduOutletSwitchedConfigPowerOnTime OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The amount of delay, in seconds, between when power is
+ provided to outlets the outlet and when this outlet
+ starts providing power"
+ ::= { pduOutletSwitchedConfigEntry 4 }
+
+pduOutletSwitchedConfigPowerOffTime OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The amount of time, in seconds, this outlet will delay
+ powering off"
+ ::= { pduOutletSwitchedConfigEntry 5 }
+
+pduOutletSwitchedConfigRebootDuration OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The amount of time, in seconds, this outlet will remain
+ in powered off state before returning to power on state
+ during a reboot action."
+ ::= { pduOutletSwitchedConfigEntry 6 }
+
+pduOutletSwitchedPropertiesTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PduOutletSwitchedPropertiesEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of PDU Switched Outlet properties"
+ ::= { pduOutlet 3 }
+
+pduOutletSwitchedPropertiesEntry OBJECT-TYPE
+ SYNTAX PduOutletSwitchedPropertiesEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An outlet properties entry containing objects for a particular outlet."
+ INDEX { pduUnitPropertiesIndex, pduOutletSwitchedPropertiesIndex }
+ ::= { pduOutletSwitchedPropertiesTable 1 }
+
+PduOutletSwitchedPropertiesEntry ::= SEQUENCE {
+ pduOutletSwitchedPropertiesIndex
+ Integer32,
+ pduOutletSwitchedPropertiesNumber
+ Integer32,
+ pduOutletSwitchedPropertiesName
+ DisplayString,
+ pduOutletSwitchedPropertiesInputPhaseLayout
+ INTEGER,
+ pduOutletSwitchedPropertiesCircuitBreaker
+ Integer32
+ }
+
+pduOutletSwitchedPropertiesIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..256)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The index of the PDU Switched Outlet properties table entry"
+ ::= { pduOutletSwitchedPropertiesEntry 1 }
+
+pduOutletSwitchedPropertiesNumber OBJECT-TYPE
+ SYNTAX Integer32 (1..256)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The numeric Switched Outlet ID"
+ ::= { pduOutletSwitchedPropertiesEntry 2 }
+
+pduOutletSwitchedPropertiesName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The user-defined switched outlet ID string"
+ ::= { pduOutletSwitchedPropertiesEntry 3 }
+
+pduOutletSwitchedPropertiesInputPhaseLayout OBJECT-TYPE
+ SYNTAX INTEGER {
+ seqPhase1ToNeutral (1),
+ seqPhase2ToNeutral (2),
+ seqPhase3ToNeutral (3),
+ seqPhase1ToPhase2 (4),
+ seqPhase2ToPhase3 (5),
+ seqPhase3ToPhase1 (6)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This OID describes the outlet phase connections
+ on the referenced bank as follows:
+ seqPhase1ToNeutral(1) indicates that outlets
+ attached to Switched Outlet are connected from Phase 1 to Neutral.
+ seqPhase2ToNeutral(2) indicates that outlets
+ attached to Switched Outlet are connected from Phase 2 to Neutral.
+ seqPhase3ToNeutral(3) indicates that outlets
+ attached to Switched Outlet are connected from Phase 3 to Neutral.
+ seqPhase1ToPhase2(4) indicates that outlets
+ attached to Switched Outlet are connected from Phase 1 to Phase2.
+ seqPhase2ToPhase3(5) indicates that outlets
+ attached to Switched Outlet are connected from Phase 2 to Phase3.
+ seqPhase3ToPhase1(6) indicates that outlets
+ attached to Switched Outlet are connected from Phase 3 to Phase1. "
+ ::= { pduOutletSwitchedPropertiesEntry 4 }
+
+pduOutletSwitchedPropertiesCircuitBreaker OBJECT-TYPE
+ SYNTAX Integer32 (1..256)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The numeric Circuit Breaker ID"
+ ::= { pduOutletSwitchedPropertiesEntry 5 }
+
+pduOutletSwitchedStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PduOutletSwitchedStatusEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of PDU Switched Outlet status data"
+ ::= { pduOutlet 4 }
+
+pduOutletSwitchedStatusEntry OBJECT-TYPE
+ SYNTAX PduOutletSwitchedStatusEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Status data from the PDU Switched Outlet being queried"
+ INDEX { pduUnitStatusIndex, pduOutletSwitchedStatusIndex }
+ ::= { pduOutletSwitchedStatusTable 1 }
+
+PduOutletSwitchedStatusEntry ::= SEQUENCE {
+ pduOutletSwitchedStatusIndex
+ Integer32,
+ pduOutletSwitchedStatusNumber
+ Integer32,
+ pduOutletSwitchedStatusName
+ DisplayString,
+ pduOutletSwitchedStatusState
+ INTEGER
+ }
+
+pduOutletSwitchedStatusIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..256)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The index of the PDU Switched Outlet status table entry"
+ ::= { pduOutletSwitchedStatusEntry 1 }
+
+pduOutletSwitchedStatusNumber OBJECT-TYPE
+ SYNTAX Integer32 (1..256)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The numeric Switched Outlet ID"
+ ::= { pduOutletSwitchedStatusEntry 2 }
+
+pduOutletSwitchedStatusName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The user-defined switched outlet ID string"
+ ::= { pduOutletSwitchedStatusEntry 3 }
+
+pduOutletSwitchedStatusState OBJECT-TYPE
+ SYNTAX INTEGER {
+ off (0),
+ on (1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the present switch state of the
+ PDU switched outlet being queried"
+ ::= { pduOutletSwitchedStatusEntry 4 }
+
+pduOutletSwitchedControlTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PduOutletSwitchedControlEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of PDU Switched Outlet status data"
+ ::= { pduOutlet 5 }
+
+pduOutletSwitchedControlEntry OBJECT-TYPE
+ SYNTAX PduOutletSwitchedControlEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Status data from the PDU Switched Outlet
+ being queried"
+ INDEX { pduUnitConfigIndex, pduOutletSwitchedControlIndex }
+ ::= { pduOutletSwitchedControlTable 1 }
+
+PduOutletSwitchedControlEntry ::= SEQUENCE {
+ pduOutletSwitchedControlIndex
+ Integer32,
+ pduOutletSwitchedControlNumber
+ Integer32,
+ pduOutletSwitchedControlName
+ DisplayString,
+ pduOutletSwitchedControlCommand
+ INTEGER
+ }
+
+pduOutletSwitchedControlIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..256)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The index to the PDU switched outlet
+ control data table entry"
+ ::= { pduOutletSwitchedControlEntry 1 }
+
+pduOutletSwitchedControlNumber OBJECT-TYPE
+ SYNTAX Integer32 (1..256)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The numeric Switched Outlet ID"
+ ::= { pduOutletSwitchedControlEntry 2 }
+
+pduOutletSwitchedControlName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The user-defined switched outlet ID string"
+ ::= { pduOutletSwitchedControlEntry 3 }
+
+pduOutletSwitchedControlCommand OBJECT-TYPE
+ SYNTAX INTEGER {
+ immediateOff (1),
+ immediateOn (2),
+ delayedOff (3),
+ delayedOn (4),
+ immediateReboot (5),
+ delayedReboot (6),
+ outletUnknown (7)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Getting this variable will return the outlet state.
+ If the outlet is on, the immediateOn (2)
+ value will be returned. If the outlet is off,
+ the immediateOff (1) value will be returned.
+ If the state of the outlet cannot be determined, the
+ outletUnknown (7) value will be returned. If the
+ outletUnknown condition should occur, all devices
+ powered by the PDU should be shut down. The PDU's
+ power should then be cycled to clear this condition.
+ Setting this variable to immediateOn (2) will immediately
+ turn the outlet on. Setting this variable to
+ immediateOff (1) will immediately turn the outlet off.
+ Setting this variable to immediateReboot (5)
+ will cause the Switched PDU to perform an immediateOff
+ command, wait the pduOutletSwitchedConfigRebootDuration
+ OID time, and then perform an immediateOn command.
+ Setting this variable to delayedOn (4) will turn the
+ outlet on after the pduOutletSwitchedConfigPowerOnTime
+ OID time has elapsed. Setting this variable to
+ delayedOff (3) will turn the outlet off after the
+ pduOutletSwitchedConfigPowerOffTime OID time has elapsed.
+ Setting this variable to delayedReboot (6) will cause
+ the Switched PDU to perform a delayedOff command, wait
+ the pduOutletSwitchedConfigRebootDuration OID time, and
+ then perform a delayedOn command."
+ ::= { pduOutletSwitchedControlEntry 4 }
+
+pduOutletMeteredTableSize OBJECT-TYPE
+ SYNTAX Integer32 (1..256)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of PDU Outlets"
+ ::= { pduOutlet 6 }
+
+pduOutletMeteredConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PduOutletMeteredConfigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of PDU Metered Outlet configuration data"
+ ::= { pduOutlet 7 }
+
+pduOutletMeteredConfigEntry OBJECT-TYPE
+ SYNTAX PduOutletMeteredConfigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An outlet configuration entry containing objects for a particular outlet."
+ INDEX { pduUnitConfigIndex, pduOutletMeteredConfigIndex }
+ ::= { pduOutletMeteredConfigTable 1 }
+
+PduOutletMeteredConfigEntry ::= SEQUENCE {
+ pduOutletMeteredConfigIndex
+ Integer32,
+ pduOutletMeteredName
+ DisplayString,
+ pduOutletMeteredConfigLowerCriticalThreshold
+ Unsigned32,
+ pduOutletMeteredConfigLowerWarningThreshold
+ Unsigned32,
+ pduOutletMeteredConfigUpperCriticalThreshold
+ Unsigned32,
+ pduOutletMeteredConfigUpperWarningThreshold
+ Unsigned32,
+ pduOutletMeteredConfigAlarmResetThreshold
+ Unsigned32,
+ pduOutletMeteredConfigAlarmStateChangeDelay
+ Unsigned32,
+ pduOutletMeteredConfigEnabledThresholds
+ BITS
+ }
+
+pduOutletMeteredConfigIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..256)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The index of the PDU Metered Outlet
+ configuration table entry"
+ ::= { pduOutletMeteredConfigEntry 1 }
+
+pduOutletMeteredName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The user-defined name for the Metered Outlet"
+ ::= { pduOutletMeteredConfigEntry 2 }
+
+pduOutletMeteredConfigLowerCriticalThreshold OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "User-defined lower critical outlet active power alarm threshold in Watts(W)."
+ ::= { pduOutletMeteredConfigEntry 3 }
+
+pduOutletMeteredConfigLowerWarningThreshold OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "User-defined lower non-critical (warning) outlet active power alarm threshold in Watts(W)."
+ ::= { pduOutletMeteredConfigEntry 4 }
+
+pduOutletMeteredConfigUpperCriticalThreshold OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "User-defined upper critical outlet active power alarm threshold in Watts(W)."
+ ::= { pduOutletMeteredConfigEntry 5 }
+
+pduOutletMeteredConfigUpperWarningThreshold OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "User-defined upper non-critical (warning) outlet active power alarm threshold in Watts(W)."
+ ::= { pduOutletMeteredConfigEntry 6 }
+
+pduOutletMeteredConfigAlarmResetThreshold OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The hysteresis used for deassertions in Watts(W)."
+ ::= { pduOutletMeteredConfigEntry 7 }
+
+pduOutletMeteredConfigAlarmStateChangeDelay OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The delay measured in samples before a state
+ is asserted. If the value is zero, then the state
+ is asserted as soon as it is detected; if it is
+ non-zero, say n, then the assertion condition must
+ exist for n+1 consecutive samples before the
+ corresponding assertion event is reported."
+ ::= { pduOutletMeteredConfigEntry 8 }
+
+pduOutletMeteredConfigEnabledThresholds OBJECT-TYPE
+ SYNTAX BITS {
+ lowerCritical (0),
+ lowerWarning (1),
+ upperWarning (2),
+ upperCritical (3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A bit string indicating which alarm
+ thresholds are enabled."
+ ::= { pduOutletMeteredConfigEntry 9 }
+
+pduOutletMeteredPropertiesTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PduOutletMeteredPropertiesEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of PDU Metered Outlet properties"
+ ::= { pduOutlet 8 }
+
+pduOutletMeteredPropertiesEntry OBJECT-TYPE
+ SYNTAX PduOutletMeteredPropertiesEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Configuration data from the PDU Metered
+ Outlet being queried"
+ INDEX { pduUnitPropertiesIndex, pduOutletMeteredPropertiesIndex }
+ ::= { pduOutletMeteredPropertiesTable 1 }
+
+PduOutletMeteredPropertiesEntry ::= SEQUENCE {
+ pduOutletMeteredPropertiesIndex
+ Integer32,
+ pduOutletMeteredPropertiesNumber
+ Integer32,
+ pduOutletMeteredPropertiesName
+ DisplayString,
+ pduOutletMeteredPropertiesInputPhaseLayout
+ INTEGER,
+ pduOutletMeteredPropertiesCircuitBreaker
+ Integer32,
+ pduOutletMeteredPropertiesPowerRating
+ Integer32
+ }
+
+pduOutletMeteredPropertiesIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..256)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The index of the PDU Metered Outlet
+ properties table entry"
+ ::= { pduOutletMeteredPropertiesEntry 1 }
+
+pduOutletMeteredPropertiesNumber OBJECT-TYPE
+ SYNTAX Integer32 (1..256)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The numeric Metered Outlet ID"
+ ::= { pduOutletMeteredPropertiesEntry 2 }
+
+pduOutletMeteredPropertiesName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The user-defined Metered outlet ID string"
+ ::= { pduOutletMeteredPropertiesEntry 3 }
+
+pduOutletMeteredPropertiesInputPhaseLayout OBJECT-TYPE
+ SYNTAX INTEGER {
+ seqPhase1ToNeutral (1),
+ seqPhase2ToNeutral (2),
+ seqPhase3ToNeutral (3),
+ seqPhase1ToPhase2 (4),
+ seqPhase2ToPhase3 (5),
+ seqPhase3ToPhase1 (6)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This OID describes the outlet phase connections
+ on the referenced bank as follows:
+ seqPhase1ToNeutral(1) indicates that outlets attached
+ to Metered Outlet are connected from Phase 1 to Neutral.
+ seqPhase2ToNeutral(2) indicates that outlets attached
+ to Metered Outlet are connected from Phase 2 to Neutral.
+ seqPhase3ToNeutral(3) indicates that outlets attached
+ to Metered Outlet are connected from Phase 3 to Neutral.
+ seqPhase1ToPhase2(4) indicates that outlets attached
+ to Metered Outlet are connected from Phase 1 to Phase2.
+ seqPhase2ToPhase3(5) indicates that outlets attached
+ to Metered Outlet are connected from Phase 2 to Phase3.
+ seqPhase3ToPhase1(6) indicates that outlets attached
+ to Metered Outlet are connected from Phase 3 to Phase1. "
+ ::= { pduOutletMeteredPropertiesEntry 4 }
+
+pduOutletMeteredPropertiesCircuitBreaker OBJECT-TYPE
+ SYNTAX Integer32 (1..256)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The numeric Circuit Breaker ID"
+ ::= { pduOutletMeteredPropertiesEntry 5 }
+
+pduOutletMeteredPropertiesPowerRating OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Maximum power rating of the PDU metered outlet"
+ ::= { pduOutletMeteredPropertiesEntry 6 }
+
+pduOutletMeteredStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PduOutletMeteredStatusEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of PDU Metered Outlet status data"
+ ::= { pduOutlet 9 }
+
+pduOutletMeteredStatusEntry OBJECT-TYPE
+ SYNTAX PduOutletMeteredStatusEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Status data from the PDU Metered Outlet being queried"
+ INDEX { pduUnitStatusIndex, pduOutletMeteredStatusIndex }
+ ::= { pduOutletMeteredStatusTable 1 }
+
+PduOutletMeteredStatusEntry ::= SEQUENCE {
+ pduOutletMeteredStatusIndex
+ Integer32,
+ pduOutletMeteredStatusNumber
+ Integer32,
+ pduOutletMeteredStatusName
+ DisplayString,
+ pduOutletMeteredStatusLoadState
+ INTEGER,
+ pduOutletMeteredStatusCurrent
+ Integer32,
+ pduOutletMeteredStatusActivePower
+ Integer32,
+ pduOutletMeteredStatusPowerFactor
+ Integer32,
+ pduOutletMeteredStatusPeakPower
+ Integer32,
+ pduOutletMeteredStatusPeakPowerTimeStamp
+ DisplayString,
+ pduOutletMeteredStatusPeakPowerStartTime
+ DisplayString,
+ pduOutletMeteredStatusResettableEnergy
+ Integer32
+ }
+
+pduOutletMeteredStatusIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..256)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The index of the PDU Metered Outlet status table entry"
+ ::= { pduOutletMeteredStatusEntry 1 }
+
+pduOutletMeteredStatusNumber OBJECT-TYPE
+ SYNTAX Integer32 (1..256)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The numeric Metered Outlet ID"
+ ::= { pduOutletMeteredStatusEntry 2 }
+
+pduOutletMeteredStatusName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The user-defined Metered outlet ID string"
+ ::= { pduOutletMeteredStatusEntry 3 }
+
+pduOutletMeteredStatusLoadState OBJECT-TYPE
+ SYNTAX INTEGER {
+ upperCritical (1),
+ upperWarning (2),
+ lowerWarning (3),
+ lowerCritical (4),
+ normal (5)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Returns the present load status of the PDU metered outlet being queried."
+ ::= { pduOutletMeteredStatusEntry 4 }
+
+pduOutletMeteredStatusCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Returns the current draw, in hundredths of Amps(A), of the load on the PDU
+ outlet being queried."
+ ::= { pduOutletMeteredStatusEntry 5 }
+
+pduOutletMeteredStatusActivePower OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Returns the power draw, in Watts(W), of the load
+ on the PDU outlet being queried."
+ ::= { pduOutletMeteredStatusEntry 6 }
+
+pduOutletMeteredStatusPowerFactor OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Returns the ratio of active to apparent power
+ of the PDU Outlet being queried"
+ ::= { pduOutletMeteredStatusEntry 7 }
+
+pduOutletMeteredStatusPeakPower OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Returns peak power consumption, in Watts(W),
+ of the Rack PDU outlet being queried."
+ ::= { pduOutletMeteredStatusEntry 8 }
+
+pduOutletMeteredStatusPeakPowerTimeStamp OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the date and time that this metered
+ outlet's peak power consumption occurred"
+ ::= { pduOutletMeteredStatusEntry 9 }
+
+pduOutletMeteredStatusPeakPowerStartTime OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the start date and time that this metered
+ outlet began recording peak power observations"
+ ::= { pduOutletMeteredStatusEntry 10 }
+
+pduOutletMeteredStatusResettableEnergy OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A user resettable energy meter measuring outlet load energy
+ consumption in tenths of Kilowatt-Hours(kWh)."
+ ::= { pduOutletMeteredStatusEntry 11 }
+
+-- Start pduExternalSensor
+pduExternalSensorTableSize OBJECT-TYPE
+ SYNTAX Integer32 (1..256)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of External Sensors"
+ ::= { pduExternalSensor 1 }
+
+pduExternalSensorNamePlateTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PduExternalSensorNamePlateEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of PDU ExternalSensorNamePlate data"
+ ::= { pduExternalSensor 2 }
+
+pduExternalSensorNamePlateEntry OBJECT-TYPE
+ SYNTAX PduExternalSensorNamePlateEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "External Sensor Name Plate data from the external
+ sensor being queried. The number of entries equals
+ the value of pduExternalSensorNamePlateTableSize."
+ INDEX { pduNamePlateIndex, pduExternalSensorNamePlateIndex }
+ ::= { pduExternalSensorNamePlateTable 1 }
+
+PduExternalSensorNamePlateEntry ::= SEQUENCE {
+ pduExternalSensorNamePlateIndex
+ Integer32,
+ pduExternalSensorNamePlateName
+ DisplayString,
+ pduExternalSensorNamePlateDescription
+ DisplayString,
+ pduExternalSensorNamePlateLocation
+ DisplayString,
+ pduExternalSensorNamePlateSerialNumber
+ DisplayString,
+ pduExternalSensorNamePlateType
+ INTEGER,
+ pduExternalSensorNamePlateUnits
+ INTEGER,
+ pduExternalSensorNamePlateIdentifier
+ Integer32
+ }
+
+pduExternalSensorNamePlateIndex OBJECT-TYPE
+ SYNTAX Integer32 (0..255)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The index of the PDU External Sensor status table entry"
+ ::= { pduExternalSensorNamePlateEntry 1 }
+
+pduExternalSensorNamePlateName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A user-defined string identifying the external sensor"
+ ::= { pduExternalSensorNamePlateEntry 2 }
+
+pduExternalSensorNamePlateDescription OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A user-defined description of the external sensor"
+ ::= { pduExternalSensorNamePlateEntry 3 }
+
+pduExternalSensorNamePlateLocation OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A user-defined string identifying the location of the PDU"
+ ::= { pduExternalSensorNamePlateEntry 4 }
+
+pduExternalSensorNamePlateSerialNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The serial number of the external sensor being queried"
+ ::= { pduExternalSensorNamePlateEntry 5 }
+
+pduExternalSensorNamePlateType OBJECT-TYPE
+ SYNTAX INTEGER {
+ temperature (1),
+ humidity (2),
+ doorSwitch (3),
+ dryContact (4),
+ spotFluid (5),
+ ropeFluid (6),
+ smoke (7),
+ beacon (8),
+ airVelocity (9),
+ modbusAdapter (17),
+ hidAdapter (18)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The type of external sensor."
+ ::= { pduExternalSensorNamePlateEntry 6 }
+
+pduExternalSensorNamePlateUnits OBJECT-TYPE
+ SYNTAX INTEGER {
+ logic (0),
+ degreeC (1),
+ degreeF (2),
+ percent (3),
+ mps (4)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The base units the external sensor is measured in.
+ This parameter does not apply to onOff, trip, vibration,
+ waterDetection, smokeDetection sensors. "
+ ::= { pduExternalSensorNamePlateEntry 7 }
+
+pduExternalSensorNamePlateIdentifier OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Unique identifier of the external sensor."
+ ::= { pduExternalSensorNamePlateEntry 8 }
+
+pduExternalSensorConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PduExternalSensorConfigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of PDU External Sensor configuration data"
+ ::= { pduExternalSensor 3 }
+
+pduExternalSensorConfigEntry OBJECT-TYPE
+ SYNTAX PduExternalSensorConfigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Configuration data from the PDU External
+ Sensor being queried"
+ INDEX { pduUnitConfigIndex, pduExternalSensorConfigIndex }
+ ::= { pduExternalSensorConfigTable 1 }
+
+PduExternalSensorConfigEntry ::= SEQUENCE {
+ pduExternalSensorConfigIndex
+ Integer32,
+ pduExternalSensorConfigLowerCriticalThreshold
+ Unsigned32,
+ pduExternalSensorConfigLowerWarningThreshold
+ Unsigned32,
+ pduExternalSensorConfigUpperCriticalThreshold
+ Unsigned32,
+ pduExternalSensorConfigUpperWarningThreshold
+ Unsigned32,
+ pduExternalSensorConfigAlarmResetThreshold
+ Unsigned32,
+ pduExternalSensorConfigAlarmStateChangeDelay
+ Unsigned32,
+ pduExternalSensorConfigEnabledThresholds
+ BITS,
+ pduExternalSensorConfigAlarmState
+ INTEGER
+ }
+
+pduExternalSensorConfigIndex OBJECT-TYPE
+ SYNTAX Integer32 (0..255)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The index of the PDU External Sensor
+ configuration table entry"
+ ::= { pduExternalSensorConfigEntry 1 }
+
+pduExternalSensorConfigLowerCriticalThreshold OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "User-defined lower critical alarm threshold in pduExternalSensorNamePlateUnits."
+ ::= { pduExternalSensorConfigEntry 2 }
+
+pduExternalSensorConfigLowerWarningThreshold OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "User-defined lower non-critical (warning) alarm threshold in pduExternalSensorNamePlateUnits."
+ ::= { pduExternalSensorConfigEntry 3 }
+
+pduExternalSensorConfigUpperCriticalThreshold OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "User-defined upper critical alarm threshold in pduExternalSensorNamePlateUnits."
+ ::= { pduExternalSensorConfigEntry 4 }
+
+pduExternalSensorConfigUpperWarningThreshold OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "User-defined upper non-critical (warning) alarm threshold in pduExternalSensorNamePlateUnits."
+ ::= { pduExternalSensorConfigEntry 5 }
+
+pduExternalSensorConfigAlarmResetThreshold OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The hysteresis used for deassertions."
+ ::= { pduExternalSensorConfigEntry 6 }
+
+pduExternalSensorConfigAlarmStateChangeDelay OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The delay measured in samples before a state is
+ asserted. If the value is zero, then the state is
+ asserted as soon as it is detected; if it is non-zero,
+ say n, then the assertion condition must exist for n+1
+ consecutive samples before the corresponding assertion
+ event is reported."
+ ::= { pduExternalSensorConfigEntry 7 }
+
+pduExternalSensorConfigEnabledThresholds OBJECT-TYPE
+ SYNTAX BITS {
+ lowerCritical (0),
+ lowerWarning (1),
+ upperWarning (2),
+ upperCritical (3),
+ binarySensorAlarm (4)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A bit string indicating which alarm
+ thresholds are enabled."
+ ::= { pduExternalSensorConfigEntry 8 }
+
+pduExternalSensorConfigAlarmState OBJECT-TYPE
+ SYNTAX INTEGER {
+ on (1),
+ off (0)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "User defined alarm state of external sensor"
+ ::= { pduExternalSensorConfigEntry 9 }
+
+pduExternalSensorStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PduExternalSensorStatusEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of PDU External Sensor status data"
+ ::= { pduExternalSensor 4 }
+
+pduExternalSensorStatusEntry OBJECT-TYPE
+ SYNTAX PduExternalSensorStatusEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Status data from the PDU External Sensor
+ being queried"
+ INDEX { pduUnitStatusIndex, pduExternalSensorStatusIndex }
+ ::= { pduExternalSensorStatusTable 1 }
+
+PduExternalSensorStatusEntry ::= SEQUENCE {
+ pduExternalSensorStatusIndex
+ Integer32,
+ pduExternalSensorStatusName
+ DisplayString,
+ pduExternalSensorStatusAisle
+ INTEGER,
+ pduExternalSensorStatusCommStatus
+ INTEGER,
+ pduExternalSensorStatusState
+ INTEGER,
+ pduExternalSensorStatusValue
+ Integer32,
+ pduExternalSensorStatusTimeStamp
+ DisplayString,
+ pduExternalSensorStatusHighPrecisionValue
+ Integer32
+ }
+
+pduExternalSensorStatusIndex OBJECT-TYPE
+ SYNTAX Integer32 (0..255)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The index of the PDU External Sensor status table entry"
+ ::= { pduExternalSensorStatusEntry 1 }
+
+pduExternalSensorStatusName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The user-defined name for the External Sensor"
+ ::= { pduExternalSensorStatusEntry 2 }
+
+pduExternalSensorStatusAisle OBJECT-TYPE
+ SYNTAX INTEGER {
+ hotAisle (1),
+ coldAisle (2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Indicates whether the external sensor is
+ in a hot or cold aisle"
+ ::= { pduExternalSensorStatusEntry 3 }
+
+pduExternalSensorStatusCommStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ notInstalled (1),
+ commsOk (2),
+ commsLost (3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The communications status of the sensor"
+ ::= { pduExternalSensorStatusEntry 4 }
+
+pduExternalSensorStatusState OBJECT-TYPE
+ SYNTAX INTEGER {
+ notPresent (0), alarmed (1), normal (2), belowLowerCritical (3), belowLowerWarning (4), aboveUpperWarning (5), aboveUpperCritical (6)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This OID reports the current state of the sensor.
+ A notPresent (0) response indicates that no sensor is attached.
+ An alarmed (1) response indicates that the sensor is present
+ and its measured reading indicates alarmed.
+ A normal (2) response indicates that the sensor is present
+ and its measured reading lies within all thresholds.
+ A belowLowerCritical (3) response indicates that the sensor
+ is present and its measured reading lies below the lower critical threshold.
+ A belowLowerWarning (4) response indicates that the sensor
+ is present and its measured reading lies below the lower warning threshold.
+ An aboveUpperWarning (5) response indicates that the sensor
+ is present and its measured reading lies above the upper warning threshold.
+ An aboveUpperCritical (6) response indicates that the sensor
+ is present and its measured reading lies above the upper critical threshold."
+ ::= { pduExternalSensorStatusEntry 5 }
+
+pduExternalSensorStatusValue OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Sensor reading in pduExternalSensorConfigUnits value."
+ ::= { pduExternalSensorStatusEntry 6 }
+
+pduExternalSensorStatusTimeStamp OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The sensor reading timestamp."
+ ::= { pduExternalSensorStatusEntry 7 }
+
+pduExternalSensorStatusHighPrecisionValue OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Temperature sensor reading in tenths of pduExternalSensorConfigUnits value.
+ This OID is applied to temperature sensor only"
+ ::= { pduExternalSensorStatusEntry 8 }
+
+-- Start pduServerPing
+pduServerPingTableSize OBJECT-TYPE
+ SYNTAX Integer32 (0..255)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of Servers"
+ ::= { pduServerPing 1 }
+
+pduServerPingTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PduServerPingEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of Server Ping data"
+ ::= { pduServerPing 2 }
+
+pduServerPingEntry OBJECT-TYPE
+ SYNTAX PduServerPingEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Server Ping data from the server being queried.
+ The number of entries equals the value of pduServerPingTableSize."
+ INDEX { pduUnitConfigIndex, pduServerPingIndex }
+ ::= { pduServerPingTable 1 }
+
+PduServerPingEntry ::= SEQUENCE {
+ pduServerPingIndex
+ Integer32,
+ pduServerPingServerIPAddress
+ DisplayString,
+ pduServerPingEnabled
+ INTEGER
+ }
+
+pduServerPingIndex OBJECT-TYPE
+ SYNTAX Integer32 (0..255)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The index of the PDU pduServerPing table entry"
+ ::= { pduServerPingEntry 1 }
+
+pduServerPingServerIPAddress OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The IP Address/host name of the server "
+ ::= { pduServerPingEntry 2 }
+
+pduServerPingEnabled OBJECT-TYPE
+ SYNTAX INTEGER {
+ false (0), true (1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Is ping enabled for this server?"
+ ::= { pduServerPingEntry 3 }
+
+-- Smart Cabinet
+
+pduUnitSmartCabinetTableSize OBJECT-TYPE
+ SYNTAX Integer32 (0..255)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of Smart Cabinet Configuration "
+ ::= { pduSmartCabinet 1 }
+
+pduUnitSmartCabinetTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PduUnitSmartCabinetEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of Smart Cabinet information"
+ ::= { pduSmartCabinet 2 }
+
+
+pduUnitSmartCabinetEntry OBJECT-TYPE
+ SYNTAX PduUnitSmartCabinetEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Information of Smart Cabinet"
+ INDEX { pduUnitConfigIndex, pduUnitSmartCabinetIndex }
+ ::= { pduUnitSmartCabinetTable 1 }
+
+PduUnitSmartCabinetEntry ::= SEQUENCE {
+ pduUnitSmartCabinetIndex
+ Integer32,
+ pduUnitSmartCabinetCardUserName
+ DisplayString,
+ pduUnitSmartCabinetCardID
+ Integer32,
+ pduUnitSmartCabinetTimestamp
+ DisplayString,
+ pduUnitSmartCabinetDoor
+ Integer32
+ }
+
+pduUnitSmartCabinetIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..256)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The index of the PDU Smart Cabinet table entry"
+ ::= { pduUnitSmartCabinetEntry 1 }
+
+pduUnitSmartCabinetCardUserName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "User name of ID card"
+ ::= { pduUnitSmartCabinetEntry 2 }
+
+pduUnitSmartCabinetCardID OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Card ID."
+ ::= { pduUnitSmartCabinetEntry 3 }
+
+pduUnitSmartCabinetTimestamp OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the date and time of information update"
+ ::= { pduUnitSmartCabinetEntry 4 }
+
+pduUnitSmartCabinetDoor OBJECT-TYPE
+ SYNTAX INTEGER {
+ HotAisle (1),
+ ColdAisle (2) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Aisle of Smart Cabinet. "
+ ::= { pduUnitSmartCabinetEntry 5 }
+
+pduUnitSmartCabinetControl OBJECT IDENTIFIER ::= { pduSmartCabinet 3 }
+
+pduUnitSmartCabinetControlUserName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "User name of ID card"
+ ::= { pduUnitSmartCabinetControl 1 }
+
+pduUnitSmartCabinetControlCardID OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Card ID."
+ ::= { pduUnitSmartCabinetControl 2 }
+
+pduUnitSmartCabinetControlTimestamp OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Indicates the date and time of information update"
+ ::= { pduUnitSmartCabinetControl 3 }
+
+pduUnitSmartCabinetControlDoor OBJECT-TYPE
+ SYNTAX INTEGER {
+ HotAisle (1),
+ ColdAisle (2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Aisle of Smart Cabinet. "
+ ::= { pduUnitSmartCabinetControl 4 }
+
+pduUnitSmartCabinetCardIDEdit OBJECT-TYPE
+ SYNTAX INTEGER {
+ grant (0), remove (1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Smart Cabinet edit CardID "
+ ::= { pduUnitSmartCabinetControl 5 }
+
+pduUnitSmartCabinetColdAisleLockState OBJECT-TYPE
+ SYNTAX INTEGER {
+ unlock (0), lock (1), notPresent (2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Smart Cabinet ColdAisle lock state "
+ ::= { pduUnitSmartCabinetControl 6 }
+
+pduUnitSmartCabinetHotAisleLockState OBJECT-TYPE
+ SYNTAX INTEGER {
+ unlock (0), lock (1), notPresent (2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Smart Cabinet HotAisle lock state "
+ ::= { pduUnitSmartCabinetControl 7 }
+
+-- Traps Information
+trapsInfo OBJECT IDENTIFIER ::= { pduTraps 1 }
+
+trapsInfoTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TrapsInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of Trap Information entries. The number of
+ entries are given by the value of pduUnitTableSize."
+ ::= { trapsInfo 1 }
+
+trapsInfoEntry OBJECT-TYPE
+ SYNTAX TrapsInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing objects used in traps"
+ INDEX { trapsInfoIndex }
+ ::= { trapsInfoTable 1 }
+
+TrapsInfoEntry ::= SEQUENCE {
+ trapsInfoIndex
+ Integer32,
+ userName
+ DisplayString,
+ userUpdated
+ DisplayString,
+ firmwareVersion
+ DisplayString,
+ roleUpdated
+ DisplayString,
+ smtpRecipients
+ DisplayString,
+ smtpServer
+ DisplayString
+ }
+
+trapsInfoIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..256)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The index of the traps table entry"
+ ::= { trapsInfoEntry 1 }
+
+
+userName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The user currently logged in."
+ ::= { trapsInfoEntry 2 }
+
+userUpdated OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The user added, deleted, or modified."
+ ::= { trapsInfoEntry 3 }
+
+firmwareVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The version of Firmware."
+ ::= { trapsInfoEntry 4 }
+
+roleUpdated OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The role added, deleted, or modified."
+ ::= { trapsInfoEntry 5 }
+
+smtpRecipients OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Comma separated list of SMTP recipients"
+ ::= { trapsInfoEntry 6 }
+
+smtpServer OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The IP address/host name of the SMTP server"
+ ::= { trapsInfoEntry 7 }
+
+pduIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "A unique value for PDU. Its value ranges between 1
+ and the value of PDU count"
+ ::= { trapsInfo 2 }
+
+externalSensorIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "A unique value for each sensor. Its value ranges between 1
+ and the value of external sensor count."
+ ::= { trapsInfo 3 }
+
+serverPing OBJECT-TYPE
+ SYNTAX INTEGER {
+ pingEnable (1),
+ pingDisable (2),
+ serverReachable (3),
+ serverNotReachable (4)
+ }
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "Whether server ping has been enabled or disabled and
+ whether the server is reachable or not reachable"
+ ::= { trapsInfo 4 }
+
+usbDevice OBJECT-TYPE
+ SYNTAX INTEGER {
+ connected (1),
+ disconnected (2)
+ }
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "Whether a USB device has been connected or disconnected"
+ ::= { trapsInfo 5 }
+
+errorDescription OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "Description of the Error"
+ ::= { trapsInfo 6 }
+
+daisyChain OBJECT-TYPE
+ SYNTAX INTEGER {
+ connected (1),
+ disconnected (2)
+ }
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "Whether a daisy chain member has been connected or disconnected"
+ ::= { trapsInfo 7 }
+
+systemCommunication OBJECT-TYPE
+ SYNTAX INTEGER {
+ ok (1),
+ lost (2)
+ }
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "Whether the Network management card has lost contact with daisy a chain member."
+ ::= { trapsInfo 8 }
+
+networkCardStart NOTIFICATION-TYPE
+ OBJECTS { pduIndex,
+ pduNamePlateName,
+ pduNamePlateInetAddressType,
+ pduNamePlateIPAddress,
+ sysContact,
+ sysName,
+ sysLocation }
+ STATUS current
+ DESCRIPTION
+ "The network card has started"
+ ::= { pduTraps 2 }
+
+networkCardReset NOTIFICATION-TYPE
+ OBJECTS { pduIndex,
+ pduNamePlateName,
+ userName,
+ pduNamePlateInetAddressType,
+ pduNamePlateIPAddress,
+ sysContact,
+ sysName,
+ sysLocation }
+ STATUS current
+ DESCRIPTION
+ "The network card was reset via the web or command line interface."
+ ::= { pduTraps 3 }
+
+userLogin NOTIFICATION-TYPE
+ OBJECTS { pduIndex,
+ pduNamePlateName,
+ userName,
+ pduNamePlateInetAddressType,
+ pduNamePlateIPAddress,
+ sysContact,
+ sysName,
+ sysLocation }
+ STATUS current
+ DESCRIPTION
+ "A user logged in"
+ ::= { pduTraps 4 }
+
+userLogoff NOTIFICATION-TYPE
+ OBJECTS { pduIndex,
+ pduNamePlateName,
+ userName,
+ pduNamePlateInetAddressType,
+ pduNamePlateIPAddress,
+ sysContact,
+ sysName,
+ sysLocation }
+ STATUS current
+ DESCRIPTION
+ " A user logged off"
+ ::= { pduTraps 5 }
+
+userAuthenticationFailed NOTIFICATION-TYPE
+ OBJECTS { pduIndex,
+ pduNamePlateName,
+ userName,
+ pduNamePlateInetAddressType,
+ pduNamePlateIPAddress,
+ sysContact,
+ sysName,
+ sysLocation }
+ STATUS current
+ DESCRIPTION
+ "A user authentication attempt failed."
+ ::= { pduTraps 6 }
+
+userSessionTimeout NOTIFICATION-TYPE
+ OBJECTS { pduIndex,
+ pduNamePlateName,
+ userName,
+ pduNamePlateInetAddressType,
+ pduNamePlateIPAddress,
+ sysContact,
+ sysName,
+ sysLocation }
+ STATUS current
+ DESCRIPTION
+ "A user session timed out"
+ ::= { pduTraps 7 }
+
+userAdded NOTIFICATION-TYPE
+ OBJECTS { pduIndex,
+ pduNamePlateName,
+ userName,
+ pduNamePlateInetAddressType,
+ pduNamePlateIPAddress,
+ userUpdated,
+ sysContact,
+ sysName,
+ sysLocation }
+ STATUS current
+ DESCRIPTION
+ "A user account was added to system."
+ ::= { pduTraps 8 }
+
+userModified NOTIFICATION-TYPE
+ OBJECTS { pduIndex,
+ pduNamePlateName,
+ userName,
+ pduNamePlateInetAddressType,
+ pduNamePlateIPAddress,
+ userUpdated,
+ sysContact,
+ sysName,
+ sysLocation }
+ STATUS current
+ DESCRIPTION
+ "A user account was modified."
+ ::= { pduTraps 9 }
+
+userDeleted NOTIFICATION-TYPE
+ OBJECTS { pduIndex,
+ pduNamePlateName,
+ userName,
+ pduNamePlateInetAddressType,
+ pduNamePlateIPAddress,
+ userUpdated,
+ sysContact,
+ sysName,
+ sysLocation }
+ STATUS current
+ DESCRIPTION
+ "A user account was deleted."
+ ::= { pduTraps 10 }
+
+roleAdded NOTIFICATION-TYPE
+ OBJECTS { pduIndex,
+ pduNamePlateName,
+ userName,
+ pduNamePlateInetAddressType,
+ pduNamePlateIPAddress,
+ roleUpdated,
+ sysContact,
+ sysName,
+ sysLocation }
+ STATUS current
+ DESCRIPTION
+ "A user role was added."
+ ::= { pduTraps 11 }
+
+roleModified NOTIFICATION-TYPE
+ OBJECTS { pduIndex,
+ pduNamePlateName,
+ userName,
+ pduNamePlateInetAddressType,
+ pduNamePlateIPAddress,
+ roleUpdated,
+ sysContact,
+ sysName,
+ sysLocation }
+ STATUS current
+ DESCRIPTION
+ "A user role was modified."
+ ::= { pduTraps 12 }
+
+roleDeleted NOTIFICATION-TYPE
+ OBJECTS { pduIndex,
+ pduNamePlateName,
+ userName,
+ pduNamePlateInetAddressType,
+ pduNamePlateIPAddress,
+ roleUpdated,
+ sysContact,
+ sysName,
+ sysLocation }
+ STATUS current
+ DESCRIPTION
+ "A user role was deleted."
+ ::= { pduTraps 13 }
+
+firmwareUpdateStarted NOTIFICATION-TYPE
+ OBJECTS { pduIndex,
+ pduNamePlateName,
+ userName,
+ pduNamePlateInetAddressType,
+ pduNamePlateIPAddress,
+ firmwareVersion,
+ sysContact,
+ sysName,
+ sysLocation }
+ STATUS current
+ DESCRIPTION
+ "A firmware update has started."
+ ::= { pduTraps 14 }
+
+firmwareUpdateCompleted NOTIFICATION-TYPE
+ OBJECTS { pduIndex,
+ pduNamePlateName,
+ userName,
+ pduNamePlateInetAddressType,
+ pduNamePlateIPAddress,
+ firmwareVersion,
+ sysContact,
+ sysName,
+ sysLocation }
+ STATUS current
+ DESCRIPTION
+ "The firmware update has completed."
+ ::= { pduTraps 15 }
+
+userBlocked NOTIFICATION-TYPE
+ OBJECTS { pduIndex,
+ pduNamePlateName,
+ userName,
+ pduNamePlateInetAddressType,
+ pduNamePlateIPAddress,
+ sysContact,
+ sysName,
+ sysLocation }
+ STATUS current
+ DESCRIPTION
+ "A user is blocked."
+ ::= { pduTraps 16 }
+
+outletControl NOTIFICATION-TYPE
+ OBJECTS { pduIndex,
+ pduNamePlateName,
+ userName,
+ pduNamePlateInetAddressType,
+ pduNamePlateIPAddress,
+ pduOutletSwitchedControlNumber,
+ pduOutletSwitchedStatusState,
+ pduOutletSwitchedControlCommand,
+ sysContact,
+ sysName,
+ sysLocation }
+ STATUS current
+ DESCRIPTION
+ "Outlet control operation applied."
+ ::= { pduTraps 17 }
+
+userPasswordChange NOTIFICATION-TYPE
+ OBJECTS { pduIndex,
+ pduNamePlateName,
+ userName,
+ pduNamePlateInetAddressType,
+ pduNamePlateIPAddress,
+ userUpdated,
+ sysContact,
+ sysName,
+ sysLocation }
+ STATUS current
+ DESCRIPTION
+ "A user password was changed. "
+ ::= { pduTraps 18 }
+
+passwordSettingsChange NOTIFICATION-TYPE
+ OBJECTS { pduIndex,
+ pduNamePlateName,
+ userName,
+ pduNamePlateInetAddressType,
+ pduNamePlateIPAddress,
+ sysContact,
+ sysName,
+ sysLocation }
+ STATUS current
+ DESCRIPTION
+ "One or more password policy settings were changed."
+ ::= { pduTraps 19 }
+
+logFileCleared NOTIFICATION-TYPE
+ OBJECTS { pduIndex,
+ pduNamePlateName,
+ userName,
+ pduNamePlateInetAddressType,
+ pduNamePlateIPAddress,
+ sysContact,
+ sysName,
+ sysLocation }
+ STATUS current
+ DESCRIPTION
+ "The log file has been cleared."
+ ::= { pduTraps 21 }
+
+pduConfigurationFileImported NOTIFICATION-TYPE
+ OBJECTS { pduIndex,
+ pduNamePlateName,
+ userName,
+ pduNamePlateInetAddressType,
+ pduNamePlateIPAddress,
+ sysContact,
+ sysName,
+ sysLocation }
+ STATUS current
+ DESCRIPTION
+ "PDU configuration file was imported."
+ ::= { pduTraps 22 }
+
+pduConfigurationFileExported NOTIFICATION-TYPE
+ OBJECTS { pduIndex,
+ pduNamePlateName,
+ userName,
+ pduNamePlateInetAddressType,
+ pduNamePlateIPAddress,
+ sysContact,
+ sysName,
+ sysLocation }
+ STATUS current
+ DESCRIPTION
+ "PDU configuration file was exported"
+ ::= { pduTraps 23 }
+
+pduUnitActivePowerStateChange NOTIFICATION-TYPE
+ OBJECTS { pduIndex,
+ pduNamePlateName,
+ pduNamePlateInetAddressType,
+ pduNamePlateIPAddress,
+ pduUnitStatusLoadState,
+ pduUnitStatusActivePower,
+ sysContact,
+ sysName,
+ sysLocation }
+ STATUS current
+ DESCRIPTION
+ "PDU unit active power state changes."
+ ::= { pduTraps 24 }
+
+pduInputphaseVoltageStateChange NOTIFICATION-TYPE
+ OBJECTS { pduIndex,
+ pduNamePlateName,
+ pduNamePlateInetAddressType,
+ pduNamePlateIPAddress,
+ pduInputPhaseStatusCount,
+ pduInputPhaseStatusVoltageState,
+ pduInputPhaseStatusVoltage,
+ sysContact,
+ sysName,
+ sysLocation }
+ STATUS current
+ DESCRIPTION
+ "PDU input phase voltage state changes."
+ ::= { pduTraps 25 }
+
+pduInputphaseCurrentStateChange NOTIFICATION-TYPE
+ OBJECTS { pduIndex,
+ pduNamePlateName,
+ pduNamePlateInetAddressType,
+ pduNamePlateIPAddress,
+ pduInputPhaseStatusCount,
+ pduInputPhaseStatusCurrentState,
+ pduInputPhaseStatusCurrent,
+ sysContact,
+ sysName,
+ sysLocation }
+ STATUS current
+ DESCRIPTION
+ "PDU input phase Current state changes."
+ ::= { pduTraps 26 }
+
+pduCircuitBreakerCurrentStateChange NOTIFICATION-TYPE
+ OBJECTS { pduIndex,
+ pduNamePlateName,
+ pduNamePlateInetAddressType,
+ pduNamePlateIPAddress,
+ pduCircuitBreakerStatusIndex,
+ pduCircuitBreakerStatusLoadState,
+ pduCircuitBreakerStatusCurrent,
+ sysContact,
+ sysName,
+ sysLocation }
+ STATUS current
+ DESCRIPTION
+ "PDU Circuit Breaker Current state changes."
+ ::= { pduTraps 27 }
+
+pduOutletActivePowerStateChange NOTIFICATION-TYPE
+ OBJECTS { pduIndex,
+ pduNamePlateName,
+ pduNamePlateInetAddressType,
+ pduNamePlateIPAddress,
+ pduOutletMeteredStatusIndex,
+ pduOutletMeteredStatusLoadState,
+ pduOutletMeteredStatusActivePower,
+ sysContact,
+ sysName,
+ sysLocation }
+ STATUS current
+ DESCRIPTION
+ "PDU Metered Outlet Active Power state changes."
+ ::= { pduTraps 28 }
+
+pduExternalSensorStateChange NOTIFICATION-TYPE
+ OBJECTS { pduIndex,
+ pduNamePlateName,
+ pduNamePlateInetAddressType,
+ pduNamePlateIPAddress,
+ pduExternalSensorStatusIndex,
+ pduExternalSensorStatusName,
+ pduExternalSensorNamePlateType,
+ pduExternalSensorStatusAisle,
+ pduExternalSensorNamePlateUnits,
+ pduExternalSensorStatusState,
+ pduExternalSensorStatusValue,
+ sysContact,
+ sysName,
+ sysLocation }
+ STATUS current
+ DESCRIPTION
+ "PDU External Sensor state changes."
+ ::= { pduTraps 29 }
+
+smtpTransmissionFailure NOTIFICATION-TYPE
+ OBJECTS { pduIndex,
+ pduNamePlateName,
+ pduNamePlateInetAddressType,
+ pduNamePlateIPAddress,
+ smtpRecipients,
+ smtpServer,
+ sysContact,
+ sysName,
+ sysLocation }
+ STATUS current
+ DESCRIPTION
+ "SMTP message transmission failed."
+ ::= { pduTraps 30 }
+
+ldapError NOTIFICATION-TYPE
+ OBJECTS { pduIndex,
+ pduNamePlateName,
+ pduNamePlateInetAddressType,
+ pduNamePlateIPAddress,
+ errorDescription,
+ sysContact,
+ sysName,
+ sysLocation }
+ STATUS current
+ DESCRIPTION
+ "A LDAP error occurred"
+ ::= { pduTraps 31 }
+
+firmwareUpdateFailed NOTIFICATION-TYPE
+ OBJECTS { pduIndex,
+ pduNamePlateName,
+ userName,
+ pduNamePlateInetAddressType,
+ pduNamePlateIPAddress,
+ firmwareVersion,
+ sysContact,
+ sysName,
+ sysLocation }
+ STATUS current
+ DESCRIPTION
+ "A firmware update has failed."
+ ::= { pduTraps 32 }
+
+serverPingState NOTIFICATION-TYPE
+ OBJECTS { pduIndex,
+ pduNamePlateName,
+ userName,
+ pduNamePlateInetAddressType,
+ pduNamePlateIPAddress,
+ pduServerPingServerIPAddress,
+ serverPing,
+ sysContact,
+ sysName,
+ sysLocation }
+ STATUS current
+ DESCRIPTION
+ "The Ping feature has been enabled."
+ ::= { pduTraps 33 }
+
+bootloaderState NOTIFICATION-TYPE
+ OBJECTS { pduIndex,
+ pduNamePlateName,
+ pduNamePlateInetAddressType,
+ pduNamePlateIPAddress,
+ sysContact,
+ sysName,
+ sysLocation }
+ STATUS current
+ DESCRIPTION
+ "Enter into Bootloader mode"
+ ::= { pduTraps 34 }
+
+daisyChainState NOTIFICATION-TYPE
+ OBJECTS { pduIndex,
+ pduNamePlateName,
+ pduNamePlateInetAddressType,
+ pduNamePlateIPAddress,
+ daisyChain,
+ sysContact,
+ sysName,
+ sysLocation }
+ STATUS current
+ DESCRIPTION
+ "A daisy chain member has been connected or disconnected."
+ ::= { pduTraps 35 }
+
+systemInternalCommunicationLost NOTIFICATION-TYPE
+ OBJECTS { pduIndex,
+ pduNamePlateName,
+ pduNamePlateInetAddressType,
+ pduNamePlateIPAddress,
+ systemCommunication,
+ sysContact,
+ sysName,
+ sysLocation }
+ STATUS current
+ DESCRIPTION
+ "Network management card has lost contaction with internal boards."
+ ::= { pduTraps 36 }
+
+
+SmartCabinetLockUnlocked NOTIFICATION-TYPE
+ OBJECTS { pduIndex,
+ pduNamePlateName,
+ pduNamePlateInetAddressType,
+ pduNamePlateIPAddress,
+ pduUnitSmartCabinetDoor,
+ pduExternalSensorStatusValue,
+ sysContact,
+ sysName,
+ sysLocation }
+ STATUS current
+ DESCRIPTION
+ "The Cabinet lock is unlocked."
+ ::= { pduTraps 37 }
+
+SmartCabinetLockLocked NOTIFICATION-TYPE
+ OBJECTS { pduIndex,
+ pduNamePlateName,
+ pduNamePlateInetAddressType,
+ pduNamePlateIPAddress,
+ pduUnitSmartCabinetDoor,
+ pduExternalSensorStatusValue,
+ sysContact,
+ sysName,
+ sysLocation }
+ STATUS current
+ DESCRIPTION
+ "The Cabinet lock is locked"
+ ::= { pduTraps 38 }
+
+SmartCabinetSwapCard NOTIFICATION-TYPE
+ OBJECTS { pduIndex,
+ pduNamePlateName,
+ pduNamePlateInetAddressType,
+ pduNamePlateIPAddress,
+ pduUnitSmartCabinetDoor,
+ pduUnitSmartCabinetCardID,
+ pduExternalSensorStatusValue,
+ sysContact,
+ sysName,
+ sysLocation }
+ STATUS current
+ DESCRIPTION
+ "Card is swapped"
+ ::= { pduTraps 39 }
+
+SmartCabinetLockerLockDoorOpen NOTIFICATION-TYPE
+ OBJECTS { pduIndex,
+ pduNamePlateName,
+ pduNamePlateInetAddressType,
+ pduNamePlateIPAddress,
+ pduUnitSmartCabinetDoor,
+ pduExternalSensorStatusValue,
+ sysContact,
+ sysName,
+ sysLocation }
+ STATUS current
+ DESCRIPTION
+ "Locker locked but door open"
+ ::= { pduTraps 40 }
+
+SmartCabinetLockerUnlockDoorClose NOTIFICATION-TYPE
+ OBJECTS { pduIndex,
+ pduNamePlateName,
+ pduNamePlateInetAddressType,
+ pduNamePlateIPAddress,
+ pduUnitSmartCabinetDoor,
+ pduExternalSensorStatusValue,
+ sysContact,
+ sysName,
+ sysLocation }
+ STATUS current
+ DESCRIPTION
+ "Locker unlocked but door close"
+ ::= { pduTraps 41 }
+
+systemReboot NOTIFICATION-TYPE
+ OBJECTS { pduIndex,
+ pduNamePlateName,
+ pduNamePlateInetAddressType,
+ pduNamePlateIPAddress,
+ sysContact,
+ sysName,
+ sysLocation }
+ STATUS current
+ DESCRIPTION
+ "System has rebooted"
+ ::= { pduTraps 50 }
+
+esp OBJECT IDENTIFIER ::= { enlogic 2 }
+espNamePlate OBJECT IDENTIFIER ::= { esp 1 }
+espUnit OBJECT IDENTIFIER ::= { esp 2 }
+espInputPhase OBJECT IDENTIFIER ::= { esp 3 }
+espCircuitBreaker OBJECT IDENTIFIER ::= { esp 4 }
+espExternalSensor OBJECT IDENTIFIER ::= { esp 6 }
+espTraps OBJECT IDENTIFIER ::= { esp 9 }
+
+-- Start espNamePlate
+
+-- espNamePlateTable
+espNamePlateTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EspNamePlateEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of es PDU nameplate data"
+ ::= { espNamePlate 2 }
+
+espNamePlateEntry OBJECT-TYPE
+ SYNTAX EspNamePlateEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Nameplate data from the PDU being queried. The numbers of entries equals the value of espNamePlateTableSize."
+ INDEX { espNamePlateIndex }
+ ::= { espNamePlateTable 1 }
+
+EspNamePlateEntry ::= SEQUENCE {
+ espNamePlateIndex
+ Integer32,
+ espNamePlateName
+ DisplayString,
+ espNamePlateLocation
+ DisplayString,
+ espNamePlateInetAddressType
+ InetAddressType,
+ espNamePlateIPAddress
+ InetAddress,
+ espNamePlateInetNetMask
+ InetAddress,
+ espNamePlateInetGateway
+ InetAddress,
+ espNamePlateMACAddress
+ MacAddress,
+ espNamePlateUTCTimeOffset
+ DisplayString,
+ espNamePlateModelNumber
+ DisplayString,
+ espNamePlateSerialNumber
+ DisplayString,
+ espNamePlateDateofManufacture
+ DisplayString,
+ espNamePlateFirmwareVersion
+ DisplayString,
+ espNamePlateFirmwareVersionTimeStamp
+ DisplayString,
+ espNamePlateType
+ INTEGER
+ }
+
+espNamePlateIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..256)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The index of the es PDU nameplate table entry"
+ ::= { espNamePlateEntry 1 }
+
+espNamePlateName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A user-defined string identifying the es PDU"
+ ::= { espNamePlateEntry 2 }
+
+espNamePlateLocation OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A user-defined string identifying the location of PDU"
+ ::= { espNamePlateEntry 3 }
+
+espNamePlateInetAddressType OBJECT-TYPE
+ SYNTAX InetAddressType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The type of address format"
+ ::= { espNamePlateEntry 4 }
+
+espNamePlateIPAddress OBJECT-TYPE
+ SYNTAX InetAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current IP address. A value of 0.0.0.0 indicates an error or an unset option"
+ ::= { espNamePlateEntry 5 }
+
+espNamePlateInetNetMask OBJECT-TYPE
+ SYNTAX InetAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current netmask. A value of 0.0.0.0 indiates an error or an unset option"
+ ::= { espNamePlateEntry 6 }
+
+espNamePlateInetGateway OBJECT-TYPE
+ SYNTAX InetAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current gateway. A value of 0.0.0.0 indicates an error or an unset option"
+ ::= { espNamePlateEntry 7 }
+
+espNamePlateMACAddress OBJECT-TYPE
+ SYNTAX MacAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The assigned MAC address for the PDU"
+ ::= { espNamePlateEntry 8 }
+
+espNamePlateUTCTimeOffset OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The difference in hours and minutes from Coordinated Universal
+ Time(UTC) for the time used in a particular time zone"
+ ::= { espNamePlateEntry 9 }
+
+espNamePlateModelNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The PDU model number"
+ ::= { espNamePlateEntry 10 }
+
+espNamePlateSerialNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The PDU serial number"
+ ::= { espNamePlateEntry 11 }
+
+espNamePlateDateofManufacture OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The date the PDU was manufactured in mm/dd/yyyy format"
+ ::= { espNamePlateEntry 12 }
+
+espNamePlateFirmwareVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The PDU firmware version"
+ ::= { espNamePlateEntry 13 }
+
+espNamePlateFirmwareVersionTimeStamp OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Timestamp of when the PDU firmware was last updated"
+ ::= { espNamePlateEntry 14 }
+
+espNamePlateType OBJECT-TYPE
+ SYNTAX INTEGER {
+ pdu (0),
+ inlineMeter (1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The type of Unit, PDU or Inline Meter"
+ ::= { espNamePlateEntry 15 }
+
+
+-- Start espUnit
+
+espUnitConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EspUnitConfigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of PDU configuration data"
+ ::= { espUnit 2 }
+
+espUnitConfigEntry OBJECT-TYPE
+ SYNTAX EspUnitConfigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Configuration data from the PDU being queried. The number of entries equals the value of espUnitTableSize"
+ INDEX { espUnitConfigIndex }
+ ::= { espUnitConfigTable 1 }
+
+EspUnitConfigEntry ::= SEQUENCE {
+ espUnitConfigIndex
+ Integer32,
+ espUnitConfigName
+ DisplayString,
+ espUnitConfigLocation
+ DisplayString,
+ espUnitConfigEnergyReset
+ INTEGER,
+ espUnitConfigResetNetworkManagementCard
+ INTEGER
+ }
+
+espUnitConfigIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..256)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The index of the PDU Unit Config Entry"
+ ::= { espUnitConfigEntry 1 }
+
+espUnitConfigName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A user-defined string identifying the PDU"
+ ::= { espUnitConfigEntry 2 }
+
+espUnitConfigLocation OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A user-defined string identifying the location of the PDU"
+ ::= { espUnitConfigEntry 3 }
+
+espUnitConfigEnergyReset OBJECT-TYPE
+ SYNTAX INTEGER {
+ noOperation (1),
+ reset (2),
+ notSupported (3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Setting this OID to reset (2) will cause the device energy meter value
+ to be reset to zero. Getting this OID in models that support this
+ feature will do nothing and return the noOperation(1) value. Models
+ that do not support this feature will respond to this OID with a
+ value of notSupported (3). Attempts to set this OID in these models will fail. "
+ ::= { espUnitConfigEntry 15 }
+
+espUnitConfigResetNetworkManagementCard OBJECT-TYPE
+ SYNTAX INTEGER {
+ noOperation (0),
+ reset (1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Getting this OID will return noOperation(0). Setting this OID to reset(1) will reset NMC."
+ ::= { espUnitConfigEntry 20 }
+
+espUnitPropertiesTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EspUnitPropertiesEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of PDU properties"
+ ::= { espUnit 3 }
+
+espUnitPropertiesEntry OBJECT-TYPE
+ SYNTAX EspUnitPropertiesEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A unit properties entry containing objects for a particular unit."
+ INDEX { espUnitPropertiesIndex }
+ ::= { espUnitPropertiesTable 1 }
+
+EspUnitPropertiesEntry ::= SEQUENCE {
+ espUnitPropertiesIndex
+ Integer32,
+ espUnitPropertiesName
+ DisplayString,
+ espUnitPropertiesOutletCount
+ Integer32,
+ espUnitPropertiesSwitchedOutletCount
+ Integer32,
+ espUnitPropertiesMeteredOutletCount
+ Integer32,
+ espUnitPropertiesInputPhaseCount
+ Integer32,
+ espUnitPropertiesCircuitBreakerCount
+ Integer32,
+ espUnitPropertiesMaxExternalSensorCount
+ Integer32,
+ espUnitPropertiesConnExternalSensorCount
+ Integer32,
+ espUnitPropertiesRatedVoltage
+ DisplayString,
+ espUnitPropertiesRatedMaxCurrent
+ DisplayString,
+ espUnitPropertiesRatedFrequency
+ DisplayString,
+ espUnitPropertiesRatedPower
+ DisplayString
+ }
+
+espUnitPropertiesIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..256)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The index of the PDU properties table entry"
+ ::= { espUnitPropertiesEntry 1 }
+
+espUnitPropertiesName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A user-defined string identifying the PDU"
+ ::= { espUnitPropertiesEntry 2 }
+
+espUnitPropertiesOutletCount OBJECT-TYPE
+ SYNTAX Integer32 (1..256)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of outlets on the PDU"
+ ::= { espUnitPropertiesEntry 3 }
+
+espUnitPropertiesSwitchedOutletCount OBJECT-TYPE
+ SYNTAX Integer32 (1..256)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of switched outlets on the PDU"
+ ::= { espUnitPropertiesEntry 4 }
+
+espUnitPropertiesMeteredOutletCount OBJECT-TYPE
+ SYNTAX Integer32 (1..256)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of metered outlets on the PDU"
+ ::= { espUnitPropertiesEntry 5 }
+
+espUnitPropertiesInputPhaseCount OBJECT-TYPE
+ SYNTAX Integer32 (1..256)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of phases on the PDU"
+ ::= { espUnitPropertiesEntry 6 }
+
+espUnitPropertiesCircuitBreakerCount OBJECT-TYPE
+ SYNTAX Integer32 (0..255)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of circuit breaker on the PDU"
+ ::= { espUnitPropertiesEntry 7 }
+
+espUnitPropertiesMaxExternalSensorCount OBJECT-TYPE
+ SYNTAX Integer32 (0..255)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The maximum number of external sensors that can be connected to the PDU"
+ ::= { espUnitPropertiesEntry 8 }
+
+espUnitPropertiesConnExternalSensorCount OBJECT-TYPE
+ SYNTAX Integer32 (0..255)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current number of external sensors connected to the PDU"
+ ::= { espUnitPropertiesEntry 9 }
+
+espUnitPropertiesRatedVoltage OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The PDU voltage rating in Volts"
+ ::= { espUnitPropertiesEntry 10 }
+
+espUnitPropertiesRatedMaxCurrent OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The PDU current rating in Amps"
+ ::= { espUnitPropertiesEntry 11 }
+
+espUnitPropertiesRatedFrequency OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The PDU frequency rating in Hz"
+ ::= { espUnitPropertiesEntry 12 }
+
+espUnitPropertiesRatedPower OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The PDU VA (VoltAmps) rating."
+ ::= { espUnitPropertiesEntry 13 }
+
+espUnitStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EspUnitStatusEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of PDU status information"
+ ::= { espUnit 4 }
+
+espUnitStatusEntry OBJECT-TYPE
+ SYNTAX EspUnitStatusEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Status information from the PDU being queried"
+ INDEX { espUnitStatusIndex }
+ ::= { espUnitStatusTable 1 }
+
+EspUnitStatusEntry ::= SEQUENCE {
+ espUnitStatusIndex
+ Integer32,
+ espUnitStatusName
+ DisplayString,
+ espUnitStatusLoadState
+ INTEGER,
+ espUnitStatusActivePower
+ Integer32,
+ espUnitStatusApparentPower
+ Integer32,
+ espUnitStatusEnergy
+ Integer32,
+ espUnitStatusResettableEnergy
+ Integer32,
+ espUnitStatusEnergyStartTime
+ DisplayString
+ }
+
+espUnitStatusIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..256)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The index of the PDU status table entry"
+ ::= { espUnitStatusEntry 1 }
+
+espUnitStatusName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A user-defined string identifying the PDU"
+ ::= { espUnitStatusEntry 2 }
+
+espUnitStatusLoadState OBJECT-TYPE
+ SYNTAX INTEGER {
+ upperCritical (1),
+ upperWarning (2),
+ lowerWarning (3),
+ lowerCritical (4),
+ normal (5)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Returns the present load status of the PDU based on Active Power."
+ ::= { espUnitStatusEntry 3 }
+
+espUnitStatusActivePower OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Returns power consumption, in Watts(W),
+ of the PDU being queried."
+ ::= { espUnitStatusEntry 4 }
+
+espUnitStatusApparentPower OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Returns power consumption, in Volt-Amps(VA)
+ of the PDU load being queried."
+ ::= { espUnitStatusEntry 5 }
+
+espUnitStatusEnergy OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Returns total energy consumed, in tenths of Kilowatt-Hours(kWh), of the PDU over its lifetime."
+ ::= { espUnitStatusEntry 9 }
+
+espUnitStatusResettableEnergy OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A user resettable energy meter measuring PDU energy consumption
+ in tenths of kilowatt-hours(kWh)."
+ ::= { espUnitStatusEntry 10 }
+
+espUnitStatusEnergyStartTime OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the date and time of the last device energy meter reset"
+ ::= { espUnitStatusEntry 11 }
+
+
+-- Start espInputPhase
+espInputPhaseConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EspInputPhaseConfigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of PDU Input Phase configuration data"
+ ::= { espInputPhase 2 }
+
+espInputPhaseConfigEntry OBJECT-TYPE
+ SYNTAX EspInputPhaseConfigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An input phase entry containing objects for a particular input phase."
+ INDEX { espUnitConfigIndex, espInputPhaseConfigIndex }
+ ::= { espInputPhaseConfigTable 1 }
+
+EspInputPhaseConfigEntry ::= SEQUENCE {
+ espInputPhaseConfigIndex
+ Integer32,
+ espInputPhaseConfigCount
+ Integer32
+ }
+
+espInputPhaseConfigIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..256)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The index of the PDU Input Phase configuration table entry"
+ ::= { espInputPhaseConfigEntry 1 }
+
+espInputPhaseConfigCount OBJECT-TYPE
+ SYNTAX Integer32 (1..256)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of Input Phases"
+ ::= { espInputPhaseConfigEntry 2 }
+
+espInputPhaseStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EspInputPhaseStatusEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of PDU Input Phase status data"
+ ::= { espInputPhase 4 }
+
+espInputPhaseStatusEntry OBJECT-TYPE
+ SYNTAX EspInputPhaseStatusEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An input phase status entry containing objects for a particular input phase."
+ INDEX { espUnitStatusIndex, espInputPhaseStatusIndex }
+ ::= { espInputPhaseStatusTable 1 }
+
+EspInputPhaseStatusEntry ::= SEQUENCE {
+ espInputPhaseStatusIndex
+ Integer32,
+ espInputPhaseStatusCount
+ Integer32,
+ espInputPhaseStatusCurrentState
+ INTEGER,
+ espInputPhaseStatusVoltageState
+ INTEGER,
+ espInputPhaseStatusCurrent
+ Integer32,
+ espInputPhaseStatusVoltage
+ Integer32,
+ espInputPhaseStatusActivePower
+ Integer32,
+ espInputPhaseStatusApparentPower
+ Integer32,
+ espInputPhaseStatusPowerFactor
+ Integer32
+ }
+
+espInputPhaseStatusIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..256)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The index of the PDU Input Phase status entry"
+ ::= { espInputPhaseStatusEntry 1 }
+
+espInputPhaseStatusCount OBJECT-TYPE
+ SYNTAX Integer32 (1..256)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The numeric Input Phase ID"
+ ::= { espInputPhaseStatusEntry 2 }
+
+espInputPhaseStatusCurrentState OBJECT-TYPE
+ SYNTAX INTEGER {
+ upperCritical (1),
+ upperWarning (2),
+ lowerWarning (3),
+ lowerCritical (4),
+ normal (5)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the present current status of the PDU Input Phase being queried"
+ ::= { espInputPhaseStatusEntry 3 }
+
+espInputPhaseStatusVoltageState OBJECT-TYPE
+ SYNTAX INTEGER {
+ upperCritical (1),
+ upperWarning (2),
+ lowerWarning (3),
+ lowerCritical (4),
+ normal (5)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the present voltage status of the PDU Input Phase being queried"
+ ::= { espInputPhaseStatusEntry 4 }
+
+espInputPhaseStatusCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Returns the current draw, in hundredths of Amps(A), of the load on the
+ PDU Input Phase being queried."
+ ::= { espInputPhaseStatusEntry 5 }
+
+espInputPhaseStatusVoltage OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Returns the voltage, in Volts(V), of the PDU Input Phase being queried."
+ ::= { espInputPhaseStatusEntry 6 }
+
+espInputPhaseStatusActivePower OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Returns power consumption, in Watts(W),
+ consumed on the PDU Input Phase being queried."
+ ::= { espInputPhaseStatusEntry 7 }
+
+espInputPhaseStatusApparentPower OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Returns power consumption, in Volt-Amps(VA),
+ of the PDU Input Phase being queried."
+ ::= { espInputPhaseStatusEntry 8 }
+
+espInputPhaseStatusPowerFactor OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Returns the ratio of active to apparent power of the PDU Input Phase being queried."
+ ::= { espInputPhaseStatusEntry 9 }
+
+-- Start espCircuitBreaker
+espCircuitBreakerConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EspCircuitBreakerConfigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of PDU Circuit Breaker configuration data"
+ ::= { espCircuitBreaker 2 }
+
+espCircuitBreakerConfigEntry OBJECT-TYPE
+ SYNTAX EspCircuitBreakerConfigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A circuit breaker configuration entry containing objects for a particular circuit breaker."
+ INDEX { espUnitConfigIndex, espCircuitBreakerConfigIndex }
+ ::= { espCircuitBreakerConfigTable 1 }
+
+EspCircuitBreakerConfigEntry ::= SEQUENCE {
+ espCircuitBreakerConfigIndex
+ Integer32,
+ espCircuitBreakerConfigCount
+ Integer32,
+ espCircuitBreakerName
+ DisplayString
+ }
+
+espCircuitBreakerConfigIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..256)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The index of the PDU Circuit Breaker configuration table entry"
+ ::= { espCircuitBreakerConfigEntry 1 }
+
+espCircuitBreakerConfigCount OBJECT-TYPE
+ SYNTAX Integer32 (0..255)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of circuit breakers on the PDU"
+ ::= { espCircuitBreakerConfigEntry 2 }
+
+espCircuitBreakerName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The label of the circuit breaker"
+ ::= { espCircuitBreakerConfigEntry 3 }
+
+espCircuitBreakerPropertiesTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EspCircuitBreakerPropertiesEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of PDU circuit breaker properties"
+ ::= { espCircuitBreaker 3 }
+
+espCircuitBreakerPropertiesEntry OBJECT-TYPE
+ SYNTAX EspCircuitBreakerPropertiesEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A circuit breaker properties entry containing objects for a particular circuit breaker."
+ INDEX { espUnitPropertiesIndex, espCircuitBreakerPropertiesIndex }
+ ::= { espCircuitBreakerPropertiesTable 1 }
+
+EspCircuitBreakerPropertiesEntry ::= SEQUENCE {
+ espCircuitBreakerPropertiesIndex
+ Integer32,
+ espCircuitBreakerPropertiesCount
+ Integer32,
+ espCircuitBreakerPropertiesInputLayout
+ INTEGER
+ }
+
+espCircuitBreakerPropertiesIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..256)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The index of the PDU Circuit Breaker properties table entry"
+ ::= { espCircuitBreakerPropertiesEntry 1 }
+
+espCircuitBreakerPropertiesCount OBJECT-TYPE
+ SYNTAX Integer32 (0..255)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Circuit Breakers"
+ ::= { espCircuitBreakerPropertiesEntry 2 }
+
+espCircuitBreakerPropertiesInputLayout OBJECT-TYPE
+ SYNTAX INTEGER {
+ seqPhase1ToNeutral (1),
+ seqPhase2ToNeutral (2),
+ seqPhase3ToNeutral (3),
+ seqPhase1ToPhase2 (4),
+ seqPhase2ToPhase3 (5),
+ seqPhase3ToPhase1 (6)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This OID describes the outlet phase connections on
+ the referenced bank as follows:
+ seqPhase1ToNeutral(1) indicates that outlets attached
+ to circuit breaker are connected from Phase 1 to Neutral.
+ seqPhase2ToNeutral(2) indicates that outlets attached
+ to circuit breaker are connected from Phase 2 to Neutral.
+ seqPhase3ToNeutral(3) indicates that outlets attached
+ to circuit breaker are connected from Phase 3 to Neutral.
+ seqPhase1ToPhase2(4) indicates that outlets attached
+ to circuit breaker are connected from Phase 1 to Phase2.
+ seqPhase2ToPhase3(5) indicates that outlets attached
+ to circuit breaker are connected from Phase 2 to Phase3.
+ seqPhase3ToPhase1(6) indicates that outlets attached
+ to circuit breaker are connected from Phase 3 to Phase1. "
+ ::= { espCircuitBreakerPropertiesEntry 3 }
+
+espCircuitBreakerStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EspCircuitBreakerStatusEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of PDU circuit breaker status data"
+ ::= { espCircuitBreaker 4 }
+
+espCircuitBreakerStatusEntry OBJECT-TYPE
+ SYNTAX EspCircuitBreakerStatusEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A circuit breaker status entry containing objects for a particular circuit breaker."
+ INDEX { espUnitStatusIndex, espCircuitBreakerStatusIndex }
+ ::= { espCircuitBreakerStatusTable 1 }
+
+EspCircuitBreakerStatusEntry ::= SEQUENCE {
+ espCircuitBreakerStatusIndex
+ Integer32,
+ espCircuitBreakerStatusCount
+ Integer32,
+ espCircuitBreakerLabel
+ DisplayString,
+ espCircuitBreakerStatusLoadState
+ INTEGER,
+ espCircuitBreakerStatusCurrent
+ Integer32
+ }
+
+espCircuitBreakerStatusIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..256)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The index of the PDU Circuit Breaker status table entry"
+ ::= { espCircuitBreakerStatusEntry 1 }
+
+espCircuitBreakerStatusCount OBJECT-TYPE
+ SYNTAX Integer32 (0..255)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Circuit Breakers"
+ ::= { espCircuitBreakerStatusEntry 2 }
+
+espCircuitBreakerLabel OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The label on the PDU identifying the circuit breaker"
+ ::= { espCircuitBreakerStatusEntry 3 }
+
+espCircuitBreakerStatusLoadState OBJECT-TYPE
+ SYNTAX INTEGER {
+ upperCritical (1),
+ upperWarning (2),
+ lowerWarning (3),
+ lowerCritical (4),
+ normal (5),
+ off (6)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the present load status of the PDU Circuit
+ Breaker being queried"
+ ::= { espCircuitBreakerStatusEntry 4 }
+
+espCircuitBreakerStatusCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Returns the current draw, in hundredths of Amps(A), of the load on
+ the PDU Circuit Breaker being queried."
+ ::= { espCircuitBreakerStatusEntry 5 }
+
+-- Start espExternalSensor
+espExternalSensorNamePlateTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EspExternalSensorNamePlateEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of PDU ExternalSensorNamePlate data"
+ ::= { espExternalSensor 2 }
+
+espExternalSensorNamePlateEntry OBJECT-TYPE
+ SYNTAX EspExternalSensorNamePlateEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "External Sensor Name Plate data from the external
+ sensor being queried. The number of entries equals
+ the value of espExternalSensorNamePlateTableSize."
+ INDEX { espNamePlateIndex, espExternalSensorNamePlateIndex }
+ ::= { espExternalSensorNamePlateTable 1 }
+
+EspExternalSensorNamePlateEntry ::= SEQUENCE {
+ espExternalSensorNamePlateIndex
+ Integer32,
+ espExternalSensorNamePlateName
+ DisplayString,
+ espExternalSensorNamePlateSerialNumber
+ DisplayString,
+ espExternalSensorNamePlateType
+ INTEGER,
+ espExternalSensorNamePlateUnits
+ INTEGER
+ }
+
+espExternalSensorNamePlateIndex OBJECT-TYPE
+ SYNTAX Integer32 (0..255)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The index of the PDU External Sensor status table entry"
+ ::= { espExternalSensorNamePlateEntry 1 }
+
+espExternalSensorNamePlateName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A user-defined string identifying the external sensor"
+ ::= { espExternalSensorNamePlateEntry 2 }
+
+espExternalSensorNamePlateSerialNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The serial number of the external sensor being queried"
+ ::= { espExternalSensorNamePlateEntry 5 }
+
+espExternalSensorNamePlateType OBJECT-TYPE
+ SYNTAX INTEGER {
+ temperature (1),
+ humidity (2),
+ doorSwitch (3),
+ dryContact (4),
+ spotFluid (5),
+ ropeFluid (6),
+ smoke (7),
+ beacon (8)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The type of external sensor."
+ ::= { espExternalSensorNamePlateEntry 6 }
+
+espExternalSensorNamePlateUnits OBJECT-TYPE
+ SYNTAX INTEGER {
+ logic (0),
+ degreeC (1),
+ degreeF (2),
+ percent (3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The base units the external sensor is measured in.
+ This parameter does not apply to onOff, trip, vibration,
+ waterDetection, smokeDetection sensors. "
+ ::= { espExternalSensorNamePlateEntry 7 }
+
+espExternalSensorConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EspExternalSensorConfigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of PDU External Sensor configuration data"
+ ::= { espExternalSensor 3 }
+
+espExternalSensorConfigEntry OBJECT-TYPE
+ SYNTAX EspExternalSensorConfigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Configuration data from the PDU External
+ Sensor being queried"
+ INDEX { espUnitConfigIndex, espExternalSensorConfigIndex }
+ ::= { espExternalSensorConfigTable 1 }
+
+EspExternalSensorConfigEntry ::= SEQUENCE {
+ espExternalSensorConfigIndex
+ Integer32,
+ espExternalSensorConfigAlarmState
+ INTEGER
+ }
+
+espExternalSensorConfigIndex OBJECT-TYPE
+ SYNTAX Integer32 (0..255)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The index of the PDU External Sensor
+ configuration table entry"
+ ::= { espExternalSensorConfigEntry 1 }
+
+espExternalSensorConfigAlarmState OBJECT-TYPE
+ SYNTAX INTEGER {
+ on (1),
+ off (0)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "User defined alarm state of external sensor"
+ ::= { espExternalSensorConfigEntry 9 }
+
+espExternalSensorStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EspExternalSensorStatusEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of PDU External Sensor status data"
+ ::= { espExternalSensor 4 }
+
+espExternalSensorStatusEntry OBJECT-TYPE
+ SYNTAX EspExternalSensorStatusEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Status data from the PDU External Sensor
+ being queried"
+ INDEX { espUnitStatusIndex, espExternalSensorStatusIndex }
+ ::= { espExternalSensorStatusTable 1 }
+
+EspExternalSensorStatusEntry ::= SEQUENCE {
+ espExternalSensorStatusIndex
+ Integer32,
+ espExternalSensorStatusName
+ DisplayString,
+ espExternalSensorStatusAisle
+ INTEGER,
+ espExternalSensorStatusCommStatus
+ INTEGER,
+ espExternalSensorStatusState
+ INTEGER,
+ espExternalSensorStatusValue
+ Integer32,
+ espExternalSensorStatusHighPrecisionValue
+ Integer32
+ }
+
+espExternalSensorStatusIndex OBJECT-TYPE
+ SYNTAX Integer32 (0..255)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The index of the PDU External Sensor status table entry"
+ ::= { espExternalSensorStatusEntry 1 }
+
+espExternalSensorStatusName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The user-defined name for the External Sensor"
+ ::= { espExternalSensorStatusEntry 2 }
+
+espExternalSensorStatusAisle OBJECT-TYPE
+ SYNTAX INTEGER {
+ hotAisle (1),
+ coldAisle (2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Indicates whether the external sensor is
+ in a hot or cold aisle"
+ ::= { espExternalSensorStatusEntry 3 }
+
+espExternalSensorStatusCommStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ notInstalled (1),
+ commsOk (2),
+ commsLost (3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The communications status of the sensor"
+ ::= { espExternalSensorStatusEntry 4 }
+
+espExternalSensorStatusState OBJECT-TYPE
+ SYNTAX INTEGER {
+ notPresent (0), alarmed (1), normal (2), belowLowerCritical (3), belowLowerWarning (4), aboveUpperWarning (5), aboveUpperCritical (6)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This OID reports the current state of the sensor.
+ A notPresent (0) response indicates that no sensor is attached.
+ An alarmed (1) response indicates that the sensor is present
+ and its measured reading indicates alarmed.
+ A normal (2) response indicates that the sensor is present
+ and its measured reading lies within all thresholds.
+ A belowLowerCritical (3) response indicates that the sensor
+ is present and its measured reading lies below the lower critical threshold.
+ A belowLowerWarning (4) response indicates that the sensor
+ is present and its measured reading lies below the lower warning threshold.
+ An aboveUpperWarning (5) response indicates that the sensor
+ is present and its measured reading lies above the upper warning threshold.
+ An aboveUpperCritical (6) response indicates that the sensor
+ is present and its measured reading lies above the upper critical threshold."
+ ::= { espExternalSensorStatusEntry 5 }
+
+espExternalSensorStatusValue OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Sensor reading in espExternalSensorConfigUnits value."
+ ::= { espExternalSensorStatusEntry 6 }
+
+espExternalSensorStatusHighPrecisionValue OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Temperature sensor reading in tenths of espExternalSensorConfigUnits value.
+ This OID is applied to temperature sensor only"
+ ::= { espExternalSensorStatusEntry 8 }
+
+
+-- Traps Information
+
+espTrapsInfoIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..256)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The index of the traps table entry"
+ ::= { espTraps 1 }
+
+
+espUserName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The user currently logged in."
+ ::= { espTraps 2 }
+
+espFirmwareVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The version of Firmware."
+ ::= { espTraps 4 }
+
+espIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "A unique value for PDU. Its value ranges between 1
+ and the value of PDU count"
+ ::= { espTraps 5 }
+
+espExternalSensorIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "A unique value for each sensor. Its value ranges between 1
+ and the value of external sensor count."
+ ::= { espTraps 6 }
+
+espErrorDescription OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "Description of the Error"
+ ::= { espTraps 7 }
+
+espNetworkCardStart NOTIFICATION-TYPE
+ OBJECTS { espIndex,
+ espNamePlateName,
+ espNamePlateInetAddressType,
+ espNamePlateIPAddress,
+ sysContact,
+ sysName,
+ sysLocation }
+ STATUS current
+ DESCRIPTION
+ "The network card has started"
+ ::= { espTraps 8 }
+
+espNetworkCardReset NOTIFICATION-TYPE
+ OBJECTS { espIndex,
+ espNamePlateName,
+ userName,
+ espNamePlateInetAddressType,
+ espNamePlateIPAddress,
+ sysContact,
+ sysName,
+ sysLocation }
+ STATUS current
+ DESCRIPTION
+ "The network card was reset via the web or command line interface."
+ ::= { espTraps 9}
+
+
+espFirmwareUpdateCompleted NOTIFICATION-TYPE
+ OBJECTS { espIndex,
+ espNamePlateName,
+ userName,
+ espNamePlateInetAddressType,
+ espNamePlateIPAddress,
+ firmwareVersion,
+ sysContact,
+ sysName,
+ sysLocation }
+ STATUS current
+ DESCRIPTION
+ "The firmware update has completed."
+ ::= { espTraps 10 }
+
+espUserPasswordChange NOTIFICATION-TYPE
+ OBJECTS { espIndex,
+ espNamePlateName,
+ userName,
+ espNamePlateInetAddressType,
+ espNamePlateIPAddress,
+ userUpdated,
+ sysContact,
+ sysName,
+ sysLocation }
+ STATUS current
+ DESCRIPTION
+ "A user password was changed. "
+ ::= { espTraps 11 }
+
+
+espLogFileCleared NOTIFICATION-TYPE
+ OBJECTS { espIndex,
+ espNamePlateName,
+ userName,
+ espNamePlateInetAddressType,
+ espNamePlateIPAddress,
+ sysContact,
+ sysName,
+ sysLocation }
+ STATUS current
+ DESCRIPTION
+ "The log file has been cleared."
+ ::= { espTraps 12 }
+
+espConfigurationFileExported NOTIFICATION-TYPE
+ OBJECTS { espIndex,
+ espNamePlateName,
+ userName,
+ espNamePlateInetAddressType,
+ espNamePlateIPAddress,
+ sysContact,
+ sysName,
+ sysLocation }
+ STATUS current
+ DESCRIPTION
+ "PDU configuration file was exported"
+ ::= { espTraps 13 }
+
+espUnitActivePowerStateChange NOTIFICATION-TYPE
+ OBJECTS { espIndex,
+ espNamePlateName,
+ espNamePlateInetAddressType,
+ espNamePlateIPAddress,
+ espUnitStatusLoadState,
+ espUnitStatusActivePower,
+ sysContact,
+ sysName,
+ sysLocation }
+ STATUS current
+ DESCRIPTION
+ "PDU unit active power state changes."
+ ::= { espTraps 14 }
+
+espInputphaseVoltageStateChange NOTIFICATION-TYPE
+ OBJECTS { espIndex,
+ espNamePlateName,
+ espNamePlateInetAddressType,
+ espNamePlateIPAddress,
+ espInputPhaseStatusCount,
+ espInputPhaseStatusVoltageState,
+ espInputPhaseStatusVoltage,
+ sysContact,
+ sysName,
+ sysLocation }
+ STATUS current
+ DESCRIPTION
+ "PDU input phase voltage state changes."
+ ::= { espTraps 15 }
+
+espInputphaseCurrentStateChange NOTIFICATION-TYPE
+ OBJECTS { espIndex,
+ espNamePlateName,
+ espNamePlateInetAddressType,
+ espNamePlateIPAddress,
+ espInputPhaseStatusCount,
+ espInputPhaseStatusCurrentState,
+ espInputPhaseStatusCurrent,
+ sysContact,
+ sysName,
+ sysLocation }
+ STATUS current
+ DESCRIPTION
+ "PDU input phase Current state changes."
+ ::= { espTraps 16 }
+
+espCircuitBreakerCurrentStateChange NOTIFICATION-TYPE
+ OBJECTS { espIndex,
+ espNamePlateName,
+ espNamePlateInetAddressType,
+ espNamePlateIPAddress,
+ espCircuitBreakerStatusIndex,
+ espCircuitBreakerStatusLoadState,
+ espCircuitBreakerStatusCurrent,
+ sysContact,
+ sysName,
+ sysLocation }
+ STATUS current
+ DESCRIPTION
+ "PDU Circuit Breaker Current state changes."
+ ::= { espTraps 17 }
+
+espExternalSensorStateChange NOTIFICATION-TYPE
+ OBJECTS { espIndex,
+ espNamePlateName,
+ espNamePlateInetAddressType,
+ espNamePlateIPAddress,
+ espExternalSensorStatusIndex,
+ espExternalSensorStatusName,
+ espExternalSensorNamePlateType,
+ espExternalSensorStatusAisle,
+ espExternalSensorNamePlateUnits,
+ espExternalSensorStatusState,
+ espExternalSensorStatusValue,
+ sysContact,
+ sysName,
+ sysLocation }
+ STATUS current
+ DESCRIPTION
+ "PDU External Sensor state changes."
+ ::= { espTraps 18 }
+
+espConfigurationFileImported NOTIFICATION-TYPE
+ OBJECTS { espIndex,
+ espNamePlateName,
+ userName,
+ espNamePlateInetAddressType,
+ espNamePlateIPAddress,
+ sysContact,
+ sysName,
+ sysLocation }
+ STATUS current
+ DESCRIPTION
+ "PDU configuration file was imported"
+ ::= { espTraps 19 }
+espNetworkUp NOTIFICATION-TYPE
+ OBJECTS { espIndex,
+ espNamePlateName,
+ userName,
+ espNamePlateInetAddressType,
+ espNamePlateIPAddress,
+ sysContact,
+ sysName,
+ sysLocation }
+ STATUS current
+ DESCRIPTION
+ "PDU Network is up "
+ ::= { espTraps 20 }
+END