+-- FILE NAME : mca.mib
+-- DATE : December 20, 2004
+-- AUTHOR : Greg Saltis
+-- PROJECT : Vortex Ethernet Card
+-- PUBLIC :
+-- PRIVATE :
+-- COPYRIGHT : Copyright (C) 2004 by Emerson Network Power
+-- ******************************************************************************
+
+-- ******************************************************************************
+-- MODIFICATION HISTORY
+--
+-- v1.0.0.0 09-06-04 grs New File.
+-- v1.0.0.1 12-20-04 grs Add Modification history
+-- Add
+-- vecMCAInformation
+-- vecMCAMessageRequests
+-- vecMCAMessageTransmissions
+-- vecMCAMessageTransmissions
+-- vecMCAMessageBadCRCs
+-- vecMCAMessageLinkErrors
+-- vecMCAMessagePartialResponses
+-- vecMCAMessageWrongPackets
+-- v1.0.0.2 01-29-05 gp
+-- Add
+-- vecMCAMessageErrorReplies
+-- Remove
+-- vecAlarmLVDAlarm
+-- vecAlarmPCUFailAlarm
+-- vecAlarmAudibleAlarmsAreQuiet
+-- vecAlarmACFail
+-- vecAlarmPasswordHasBeenViewed
+-- vecAlarmAudibleRelayDeEnergized
+-- v1.0.0.3 07-05-05 gp
+-- Add vecAnalogBatteryReserveHours
+--
+-- v2.0.0.3 07-12-05 gp
+-- Add
+-- vecAlarmBatteryPoorHealth
+-- vecAlarmBatteryReserveLow
+--
+-- Grouped all battery related traps together.
+--
+-- v2.0.0.4 10-05-05 gp
+-- Add versioning mechanism to MIB. Version information is
+-- added to DEFINITIONS statement as follows:
+-- VEC-MIBvX DEFINITIONS ::=
+--
+-- v3.0 10-31-05 gp
+-- Add
+-- vecHVSActive
+-- vecRemoteHVSActive
+-- vecRemoteEstopActive
+--
+-- v4.0 12-13-05 gp
+-- Changed company name
+-- Revamped to highlight power system information.
+--
+-- 12-15-05 gp
+-- Corrected incorrect labeling for PCU Total current.
+--
+-- v5.0 12-16-05 gp
+-- VEC no longer issues traps for the following MCA alarm conditions:
+-- general LVD No Reply alarm
+-- general LVD Board Fail alarm
+-- general Temperature Sensor Hi or Lo alarm
+-- general Temperature Sensor High alarm
+-- general Temperature Sensor Low alarm
+-- general Temperature Sensor No Reply alarm
+-- general Shunt Type alarm
+-- general Shunt No Reply alarm
+--
+-- v5.1 8-04-08 jws
+-- Update IMPORTS
+-- Added module identity
+-- Removed SIZE clause
+--
+-- v5.4 9-22-08 jws
+-- Changed trap object tables to NOTIFICATION-TYPE
+--
+-- v5.5 9-23-08 jws
+-- Typo correction on psAlarmSysInfoString2
+--
+-- v5.6 10-01-08 gp
+-- Corrected vecMIB OID. Replaced references to vec OID with vecMIB.
+--
+-- v5.7 02-11-11 gp
+-- Add
+-- psAlarm
+-- psHighestSeverityLevel
+-- psTemperatureAlarmStatus
+-- psLVDCircuitAAlarmStatus
+-- psLVDCircuitBAlarmStatus
+-- psShuntAlarmStatus
+--
+--
+-- v5.7 08-28-12 jws
+-- Corrected Syntax error invalues of INTEGER
+-- spaces removed
+-- ******************************************************************************
+
+VEC-MIBv5-9 DEFINITIONS ::=
+BEGIN
+
+ IMPORTS
+ MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
+ Integer32, Counter32, enterprises
+ FROM SNMPv2-SMI
+ TEXTUAL-CONVENTION, DisplayString, DateAndTime
+ FROM SNMPv2-TC;
+
+vecMIB MODULE-IDENTITY
+ LAST-UPDATED "201401140823Z"
+ ORGANIZATION "
+ Emerson Energy Systems North America (ESNA)"
+ CONTACT-INFO "
+ Emerson Energy Systems North America
+ 1510 Kansas Ave.
+ Lorain, OH 44052
+ USA "
+ DESCRIPTION "
+ Emerson Energy Systems North America(ESNA) VEC MIB. revision 5.9"
+
+ ::= { enterprises 885 3 }
+
+-- OBJECTS
+ emersonESNA OBJECT IDENTIFIER ::= { enterprises 885 }
+
+ vecInformation OBJECT IDENTIFIER ::= { vecMIB 1 }
+ vecMessageStats OBJECT IDENTIFIER ::= { vecInformation 2 }
+ psStatus OBJECT IDENTIFIER ::= { vecMIB 2 }
+ psMeasurement OBJECT IDENTIFIER ::= { psStatus 1 }
+ psTraps OBJECT IDENTIFIER ::= { vecMIB 3 }
+ psAlarmsGeneral1 OBJECT IDENTIFIER ::= { psTraps 1 }
+ psAlarmsGeneral2 OBJECT IDENTIFIER ::= { psTraps 2 }
+ psAlarmsBattery OBJECT IDENTIFIER ::= { psTraps 3 }
+
+-- ENTRIES
+
+ vecFirmwareVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "VEC System Firmware Version."
+ ::= { vecInformation 1}
+
+ vecMessageRequests OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of message requests."
+ ::= { vecMessageStats 1 }
+
+ vecMessageTransmissions OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of messages transmitted."
+ ::= { vecMessageStats 2 }
+
+ vecMessageNoResponses OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of no responses."
+ ::= { vecMessageStats 3 }
+
+ vecMessageBadCRCs OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of bad CRC checks."
+ ::= { vecMessageStats 4 }
+
+ vecMessageLinkErrors OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of link errors."
+ ::= { vecMessageStats 5 }
+
+ vecMessagePartialResponses OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of partial responses received."
+ ::= { vecMessageStats 6 }
+
+ vecMessageWrongPackets OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of wrong packet numbers detected."
+ ::= { vecMessageStats 7 }
+
+ vecMessageErrorReplies OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of error responses received."
+ ::= { vecMessageStats 8 }
+
+ psSystemVoltage OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "System Voltage."
+ ::= { psMeasurement 1}
+
+ psSystemCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "System Current."
+ ::= { psMeasurement 2}
+
+ psSubsystemVoltage OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Sub System Voltage."
+ ::= { psMeasurement 3}
+
+ psSubsystemCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Sub System Current."
+ ::= { psMeasurement 4}
+
+ psSenseVoltage OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Sense Voltage."
+ ::= { psMeasurement 5}
+
+ psPCUTotalCurrent OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total PCU Current."
+ ::= { psMeasurement 6}
+
+ psBatteryCurrent OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total Battery Current."
+ ::= { psMeasurement 7}
+
+ psBatteryReserveHours OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Battery Reserve Time."
+ ::= { psMeasurement 8}
+
+ psAlarm OBJECT-TYPE
+ SYNTAX INTEGER {
+ false(0),
+ true(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A Power System Alarm Is Active."
+ ::= { psMeasurement 9 }
+
+ psHighestSeverityLevel OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal(0),
+ minor(1),
+ major(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The severity level is the highest active alarm level.
+ Values: 0 = Normal, 1 = Minor, 2 = Major"
+ ::= { psMeasurement 10}
+
+ psNumberOfPCUsInstalled OBJECT-TYPE
+ SYNTAX Integer32(0..80)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of PCUs installed"
+ ::= { psMeasurement 11}
+
+ psNumberOfPCUsCommunicating OBJECT-TYPE
+ SYNTAX Integer32(0..80)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of PCUs communicating"
+ ::= { psMeasurement 12}
+
+ psTemperatureTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PSTemperatureEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Temperature Measurement Table."
+ ::= { psStatus 2 }
+
+ psTemperatureEntry OBJECT-TYPE
+ SYNTAX PSTemperatureEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Temperature Measurement Table Entry."
+ INDEX { psTemperatureIndex }
+ ::= { psTemperatureTable 1 }
+
+ PSTemperatureEntry ::= SEQUENCE {
+ psTemperatureIndex Integer32,
+ psTemperatureMeasurement DisplayString,
+ psTemperatureAlarmStatus Integer32
+ }
+
+ psTemperatureIndex OBJECT-TYPE
+ SYNTAX Integer32(1..8)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Temperature Probe Number "
+ ::= { psTemperatureEntry 1 }
+
+ psTemperatureMeasurement OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Temperature Value In Centigrade."
+ ::= { psTemperatureEntry 2 }
+
+ psTemperatureAlarmStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ high(0),
+ low(1),
+ noreply(2),
+ none(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Temperature Probe Alarm Status "
+ ::= { psTemperatureEntry 3 }
+
+ psLVDTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PSLVDEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Low Voltage Disconnect Table."
+ ::= { psStatus 3 }
+
+ psLVDEntry OBJECT-TYPE
+ SYNTAX PSLVDEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Low Voltage Disconnect Table Entry."
+ INDEX { psLVDIndex }
+ ::= { psLVDTable 1 }
+
+ PSLVDEntry ::= SEQUENCE {
+ psLVDIndex Integer32,
+ psLVDCircuitA DisplayString,
+ psLVDCircuitB DisplayString,
+ psLVDCircuitAAlarmStatus Integer32,
+ psLVDCircuitBAlarmStatus Integer32
+ }
+
+ psLVDIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "LVD Number "
+ ::= { psLVDEntry 1 }
+
+ psLVDCircuitA OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "LVD Circuit A Disconnect Voltage "
+ ::= { psLVDEntry 2 }
+
+ psLVDCircuitB OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "LVD Circuit B Disconnect Voltage "
+ ::= { psLVDEntry 3 }
+
+ psLVDCircuitAAlarmStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ disconnected(0),
+ noreply(1),
+ boardfail(2),
+ none(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "LVD Circuit A Alarm Status "
+ ::= { psLVDEntry 4 }
+
+ psLVDCircuitBAlarmStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ disconnected(0),
+ noreply(1),
+ boardfail(2),
+ none(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "LVD Circuit B Alarm Status "
+ ::= { psLVDEntry 5 }
+
+ psDistributionTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PSShuntEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Shunt Pod Table"
+ ::= { psStatus 4 }
+
+ psShuntEntry OBJECT-TYPE
+ SYNTAX PSShuntEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Shunt Pod Table Entry."
+ INDEX { psShuntIndex }
+ ::= { psDistributionTable 1 }
+
+ PSShuntEntry ::= SEQUENCE {
+ psShuntIndex Integer32,
+ psShuntCurrent DisplayString,
+ psShuntAlarmStatus Integer32,
+ psShuntType Integer32
+ }
+
+ psShuntIndex OBJECT-TYPE
+ SYNTAX Integer32(1..16)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Shunt Pod Number."
+ ::= { psShuntEntry 1 }
+
+ psShuntCurrent OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Shunt POD Current."
+ ::= { psShuntEntry 2 }
+
+ psShuntAlarmStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ type(0),
+ noreply(1),
+ none(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Shunt POD Alarm Status.
+ Values: 0 = Type, 1 = No Reply, 2 = No Alarm"
+ ::= { psShuntEntry 3 }
+
+ psShuntType OBJECT-TYPE
+ SYNTAX INTEGER {
+ system(1),
+ subsystem(2),
+ battery(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Shunt POD Alarm Status.
+ Values: 0 = System, 1 = Subsystem, 2 = Battery"
+ ::= { psShuntEntry 4 }
+
+ psPCUTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PSPCUEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "PCU Table."
+ ::= { psStatus 5 }
+
+ psPCUEntry OBJECT-TYPE
+ SYNTAX PSPCUEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "PCU Table Entry."
+ INDEX { psPCUIndex }
+ ::= { psPCUTable 1 }
+
+ PSPCUEntry ::= SEQUENCE {
+ psPCUIndex Integer32,
+ psPCUFail Integer32,
+ psPCUCurrent Integer32,
+ psPCUFerroGateway Integer32,
+ psPCUProductNumber DisplayString,
+ psPCUSWVersion DisplayString,
+ psPCUSerialNumber DisplayString,
+ psPCUCapacity DisplayString
+ }
+
+ psPCUIndex OBJECT-TYPE
+ SYNTAX Integer32(1..80)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "PCU Number."
+ ::= { psPCUEntry 1 }
+
+ psPCUFail OBJECT-TYPE
+ SYNTAX INTEGER {
+ false(0),
+ true(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "PCU Fail Alarm"
+ ::= { psPCUEntry 2 }
+
+ psPCUCurrent OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "PCU Current"
+ ::= { psPCUEntry 3 }
+
+ psPCUFerroGateway OBJECT-TYPE
+ SYNTAX INTEGER {
+ false(0),
+ true(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "PCU is a Ferro Gateway Rectifier."
+ ::= { psPCUEntry 4 }
+
+ psPCUProductNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Rectifier Product Number."
+ ::= { psPCUEntry 5}
+
+ psPCUSWVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Rectifier Software Revision."
+ ::= { psPCUEntry 6}
+
+ psPCUSerialNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Rectifier Serial Number."
+ ::= { psPCUEntry 7}
+
+ psPCUCapacity OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Rectifier Rated Current"
+ ::= { psPCUEntry 8 }
+
+ psEmergencyStop NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Emergency Stop Alarm."
+ ::= { psAlarmsGeneral1 1 }
+
+ psAlarmVeryLowVoltage NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "50 Percent Battery On Discharge Alarm."
+ ::= { psAlarmsGeneral1 2 }
+
+ psAlarmLowVoltage NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Battery On Discharge Alarm."
+ ::= { psAlarmsGeneral1 3 }
+
+ psAlarmSystemHighVoltage1 NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "High Voltage 1 Alarm."
+ ::= { psAlarmsGeneral1 4 }
+
+ psAlarmSystemHighVoltage2 NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "High Voltage 2 Alarm."
+ ::= { psAlarmsGeneral1 5 }
+
+ psAlarmSubsystemLowVoltage NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Subsystem Low Voltage Alarm."
+ ::= { psAlarmsGeneral1 6 }
+
+ psAlarmSubsystemHighVoltage NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Subsystem High Voltage Alarm."
+ ::= { psAlarmsGeneral1 7 }
+
+ psAlarmSystemFuse NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "System Fuse Alarm."
+ ::= { psAlarmsGeneral1 8 }
+
+ psAlarmSubsystemFuse NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Subsystem Fuse Alarm."
+ ::= { psAlarmsGeneral1 9 }
+
+ psAlarmAllACOff NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "All AC Off Alarm."
+ ::= { psAlarmsGeneral1 10 }
+
+ psAlarmSystemOverCurrent NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "System Over Current Alarm."
+ ::= { psAlarmsGeneral1 11 }
+
+ psAlarmSubsystemOverCurrent NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Subsystem Over Current Alarm."
+ ::= { psAlarmsGeneral1 12 }
+
+ psAlarmLVDsAreInhibited NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "LVDs Are Inhibited Alarm."
+ ::= { psAlarmsGeneral1 13 }
+
+ psAlarmTestEqualizeMode NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Test/Equalize Mode Active."
+ ::= { psAlarmsGeneral1 14 }
+
+ psAlarmMinor NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "System Minor Alarm."
+ ::= { psAlarmsGeneral1 15 }
+
+ psAlarmMajor NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "System Major Alarm."
+ ::= { psAlarmsGeneral1 16 }
+
+ psAlarmSenseVoltageFuse NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Sense Voltage Fuse Alarm."
+ ::= { psAlarmsGeneral1 17 }
+
+ psAlarmSystemVoltageFuse NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "System Voltage Fuse Alarm."
+ ::= { psAlarmsGeneral1 18 }
+
+ psAlarmNoSystemVoltage NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "No System Voltage Alarm."
+ ::= { psAlarmsGeneral1 19 }
+
+ psAlarmNoSubsystemVoltage NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "No Subsystem Voltage Alarm."
+ ::= { psAlarmsGeneral1 20 }
+
+ psAlarmNoSenseVoltage NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "No Sense Voltage Alarm."
+ ::= { psAlarmsGeneral1 21 }
+
+ psAlarmDisplayNoReply NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Display Communications Alarm."
+ ::= { psAlarmsGeneral1 22 }
+
+ psAlarmSubsystemMajor NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Subsystem Major Alarm."
+ ::= { psAlarmsGeneral1 23 }
+
+ psAlarmSubsystemMinor NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Subsystem Minor Alarm."
+ ::= { psAlarmsGeneral1 24 }
+
+ psAlarmHighACLine NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ " High AC Line Alarm."
+ ::= { psAlarmsGeneral1 25 }
+
+ psAlarmSenseVoltageError NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Sense Voltage Error Alarm."
+ ::= { psAlarmsGeneral1 26 }
+
+ psTestEqualizeHardwareInput NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "The MCA Test Equalize Hardware Input Active."
+ ::= { psAlarmsGeneral2 1 }
+
+ psPCUFailMajor NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "PCU Fail Major Alarm."
+ ::= { psAlarmsGeneral2 2 }
+
+ psPCUFailMinor NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "PCU Fail Minor Alarm."
+ ::= { psAlarmsGeneral2 3 }
+
+ psLVDAlarmMajor NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "LVD Major Alarm."
+ ::= { psAlarmsGeneral2 4 }
+
+ psLVDAlarmMinor NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "LVD Minor Alarm."
+ ::= { psAlarmsGeneral2 5 }
+
+ psPCULoadShare NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "PCU Load Share Alarm."
+ ::= { psAlarmsGeneral2 6 }
+
+ psACFailMajor NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "AC Fail Major Alarm."
+ ::= { psAlarmsGeneral2 7 }
+
+ psACFailMinor NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "AC Fail Minor Alarm."
+ ::= { psAlarmsGeneral2 8 }
+
+ psMCACommFail NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "MCA Communications Failure Alarm."
+ ::= { psAlarmsGeneral2 9 }
+
+ psHVSActive NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "High Voltage Shutdown Active."
+ ::= { psAlarmsGeneral2 10 }
+
+ psRemoteHVSActive NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Remote High Voltage Shutdown Active."
+ ::= { psAlarmsGeneral2 11 }
+
+ psRemoteEstopActive NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Remote Emergency Stop Active."
+ ::= { psAlarmsGeneral2 12 }
+
+ psAlarmBatteryChargeOverCurrent NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Battery Charge Over Current Alarm."
+ ::= { psAlarmsBattery 1 }
+
+ psBatteryCurrentLimitInhibited NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Battery Current Limit Inhibited Alarm."
+ ::= { psAlarmsBattery 2 }
+
+ psAlarmBatteryPoorHealth NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Battery Poor Health Alarm."
+ ::= { psAlarmsBattery 3 }
+
+ psAlarmBatteryReserveLow NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Battery Reserve Low Alarm."
+ ::= { psAlarmsBattery 4 }
+
+psPCUSummaryTypeTraps OBJECT IDENTIFIER ::= { psTraps 4 }
+psPCUSummaryTraps OBJECT IDENTIFIER ::= { psPCUSummaryTypeTraps 1 }
+
+ psAlarmPCUSummary NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "PCU Alarm Active."
+ ::= { psPCUSummaryTraps 2 }
+
+psPCUNodeTypeTraps OBJECT IDENTIFIER ::= { psTraps 5 }
+psPCUTraps OBJECT IDENTIFIER ::= { psPCUNodeTypeTraps 1 }
+
+ psAlarmPCUId OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "PCU Number."
+ ::= { psPCUTraps 1 }
+
+ psAlarmPCUHighACLine NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "PCU High AC Line Alarm."
+ ::= { psPCUTraps 2 }
+
+ psAlarmPCUControllerFailure NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "PCU Controller Failure Alarm."
+ ::= { psPCUTraps 3 }
+
+ psAlarmPCUFanSlowOrStopped NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "PCU Fan Slow Or Stopped Alarm."
+ ::= { psPCUTraps 4 }
+
+ psAlarmPCUTurnedOffByMca NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "PCU Turned Off By MCA."
+ ::= { psPCUTraps 5 }
+
+ psAlarmPCUCircuitBreakerOff NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "PCU Circuit Breaker Off Alarm."
+ ::= { psPCUTraps 6 }
+
+ psAlarmPCUDCorACConvertFail NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "PCU Converter Fail Alarm."
+ ::= { psPCUTraps 7 }
+
+ psAlarmPCUThermalAlarmorCurrentLimit NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "PCU Thermal Current Limit Alarm."
+ ::= { psPCUTraps 8 }
+
+ psAlarmPCUEmergencyStop NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "PCU Emergency Stop Alarm."
+ ::= { psPCUTraps 9 }
+
+ psAlarmPCUInputSwitchOff NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "PCU Input Switch Off Alarm."
+ ::= { psPCUTraps 10 }
+
+ psAlarmPCUHighVoltageShutdown NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "PCU High Voltage Shutdown Alarm."
+ ::= { psPCUTraps 11 }
+
+ psAlarmPCUACInputIsOffOrLow NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "PCU AC Input Is Off Or Low Alarm."
+ ::= { psPCUTraps 12 }
+
+ psAlarmPCUCommunicationFailureWithMCA NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "PCU Communication Failure Alarm."
+ ::= { psPCUTraps 13 }
+
+ psAlarmPCUSenseLeadOpen NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "PCU Sense Lead Open Alarm."
+ ::= { psPCUTraps 14 }
+
+psShuntTypeTraps OBJECT IDENTIFIER ::= { psTraps 6 }
+psShuntTraps OBJECT IDENTIFIER ::= { psShuntTypeTraps 1 }
+
+ psAlarmShuntId OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Shunt POD Number."
+ ::= { psShuntTraps 1 }
+
+ psAlarmShuntType NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Shunt POD Type Alarm."
+ ::= { psShuntTraps 2 }
+
+ psAlarmShuntNoReply NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Shunt POD Communications Alarm."
+ ::= { psShuntTraps 3 }
+
+
+psLVDTypeTraps OBJECT IDENTIFIER ::= { psTraps 7 }
+psLVDTraps OBJECT IDENTIFIER ::= { psLVDTypeTraps 1 }
+
+ psAlarmLVDId OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The Analog LVD Number "
+ ::= { psLVDTraps 1 }
+
+ psAlarmLVDDisconnectedA NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "LVD Circuit A Disconnected Alarm."
+ ::= { psLVDTraps 2 }
+
+ psAlarmLVDNoReplyA NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "LVD Circuit A Communications Alarm."
+ ::= { psLVDTraps 3 }
+
+ psAlarmLVDBoardFailA NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "LVD Board Circuit A Fail Alarm."
+ ::= { psLVDTraps 4 }
+
+ psAlarmLVDDisconnectedB NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "LVD Circuit B Disconnected Alarm."
+ ::= { psLVDTraps 5 }
+
+ psAlarmLVDNoReplyB NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "LVD Circuit B No Communications Alarm."
+ ::= { psLVDTraps 6 }
+
+ psAlarmLVDBoardFailB NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "LVD Board Circuit B Fail Alarm."
+ ::= { psLVDTraps 7 }
+
+psTemperatureTypeTraps OBJECT IDENTIFIER ::= { psTraps 8 }
+psTemperatureTraps OBJECT IDENTIFIER ::= { psTemperatureTypeTraps 1 }
+
+ psAlarmTemperatureId OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Temperature Probe Number."
+ ::= { psTemperatureTraps 1 }
+
+ psAlarmTemperatureHigh NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Temperature High Alarm."
+ ::= { psTemperatureTraps 2 }
+
+ psAlarmTemperatureLow NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Temperature Low Alarm."
+ ::= { psTemperatureTraps 3 }
+
+ psAlarmTemperatureNoReply NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Temperature Communications Alarm."
+ ::= { psTemperatureTraps 4 }
+
+psSysInfoTypeTraps OBJECT IDENTIFIER ::= { psTraps 9 }
+psSysInfoTraps OBJECT IDENTIFIER ::= { psSysInfoTypeTraps 1 }
+
+ psAlarmSysInfoError1 NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "SysInfo Error 1."
+ ::= { psSysInfoTraps 1 }
+
+ psAlarmSysInfoError2 NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "SysInfo Error 2."
+ ::= { psSysInfoTraps 2 }
+
+ psAlarmSysInfoString1 NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "SysInfo String 1."
+ ::= { psSysInfoTraps 3 }
+
+ psAlarmSysInfoString2 NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "SysInfo String 2."
+ ::= { psSysInfoTraps 4 }
+
+ psAlarmSysInfoString3 NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "SysInfo String 3."
+ ::= { psSysInfoTraps 5 }
+
+ psAlarmSysInfoString4 NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "SysInfo String 4."
+ ::= { psSysInfoTraps 6 }
+
+ psAlarmSysInfoString5 NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "SysInfo String 5."
+ ::= { psSysInfoTraps 7 }
+
+ psAlarmSysInfoString6 NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "SysInfo String 6."
+ ::= { psSysInfoTraps 8 }
+
+ psAlarmSysInfoString7 NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "SysInfo String 7."
+ ::= { psSysInfoTraps 9 }
+
+ psAlarmSysInfoString8 NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "SysInfo String 8."
+ ::= { psSysInfoTraps 10 }
+
+ psAlarmSysInfoString9 NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "SysInfo String 9."
+ ::= { psSysInfoTraps 11 }
+
+ psAlarmSysInfoString10 NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "SysInfo String 10."
+ ::= { psSysInfoTraps 12 }
+END