summaryrefslogtreecommitdiff
path: root/MIBS/deltanet
diff options
context:
space:
mode:
Diffstat (limited to 'MIBS/deltanet')
-rw-r--r--MIBS/deltanet/Deltanet-MIB19
-rw-r--r--MIBS/deltanet/LAMBDATRAIL-MIB1147
-rw-r--r--MIBS/deltanet/Lambdatrail2s-MIB1143
3 files changed, 2309 insertions, 0 deletions
diff --git a/MIBS/deltanet/Deltanet-MIB b/MIBS/deltanet/Deltanet-MIB
new file mode 100644
index 0000000..8ff36c2
--- /dev/null
+++ b/MIBS/deltanet/Deltanet-MIB
@@ -0,0 +1,19 @@
+Deltanet-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ enterprises, MODULE-IDENTITY
+ FROM SNMPv2-SMI;
+
+deltanet MODULE-IDENTITY
+ LAST-UPDATED "201411060000Z"
+ ORGANIZATION "DeltaNet AG Switzerland"
+ CONTACT-INFO "http://www.deltanet.ch"
+ DESCRIPTION "MIB module for defining Deltanet headers."
+ REVISION "201411060000Z"
+ DESCRIPTION "Initial Version"
+ ::= { enterprises 35616 }
+
+productType OBJECT IDENTIFIER ::= { deltanet 2 }
+xwdm OBJECT IDENTIFIER ::= { productType 1 }
+
+END
diff --git a/MIBS/deltanet/LAMBDATRAIL-MIB b/MIBS/deltanet/LAMBDATRAIL-MIB
new file mode 100644
index 0000000..e3606fb
--- /dev/null
+++ b/MIBS/deltanet/LAMBDATRAIL-MIB
@@ -0,0 +1,1147 @@
+LAMBDATRAIL-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ enterprises, private, NetworkAddress,
+ IpAddress, Counter, Gauge, TimeTicks
+ FROM RFC1155-SMI
+ OBJECT-TYPE
+ FROM RFC-1212;
+
+ DisplayString ::=
+ OCTET STRING
+ -- This data type is used to model textual information taken
+ -- from the NVT ASCII character set. By convention, objects
+ -- with this syntax are declared as having
+
+
+
+ --
+ -- SIZE (0..255)
+
+ PhysAddress ::=
+ OCTET STRING
+ -- This data type is used to model media addresses. For many
+ -- types of media, this will be in a binary representation.
+ -- For example, an ethernet address would be represented as
+ -- a string of 6 octets.
+
+-- revision date: Apr. 09, 2010
+
+deltanet OBJECT IDENTIFIER ::= { enterprises 35616 }
+
+-- Deltanet AG Specific Objects
+
+snmpAgent OBJECT IDENTIFIER ::= { deltanet 1 }
+productType OBJECT IDENTIFIER ::= { deltanet 2 }
+
+cwdm OBJECT IDENTIFIER ::= { productType 1 }
+
+lambdatrail OBJECT IDENTIFIER ::= { cwdm 1 }
+
+-- Software group
+
+agentSw OBJECT IDENTIFIER ::= { snmpAgent 1 }
+
+agentSoftwareMajorVer OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The major software version number of the agent
+ run time image."
+ ::= { agentSw 1 }
+
+agentSoftwareMinorVer OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The minor software version number of the agent
+ run time image."
+ ::= { agentSw 2 }
+
+agentOutBandBaudRate OBJECT-TYPE
+ SYNTAX INTEGER {
+ b9600(9600),
+ b19200(19200),
+ b38400(38400),
+ b57600(57600),
+ b115200(115200)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The baud rate setting for the out-of-band port."
+ ::= { snmpAgent 2 }
+
+agentConsoleIdleTimeouts OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "timeouts is 0 or 60-86400, unit is second, 0: never idle,
+ default is 600"
+ ::= { snmpAgent 3 }
+
+agentPrompt OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (1..31))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " "
+ ::= { snmpAgent 4 }
+
+agentBootMethod OBJECT-TYPE
+ SYNTAX INTEGER {
+ manual(1),
+ dhcp(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " "
+ ::= { snmpAgent 5 }
+
+agentIpAddr OBJECT-TYPE
+ SYNTAX IpAddress
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The agent's administrative IP address. The
+ current operational IP address can be obtained from
+ the ipAdEntAddr in the ipAddrTable. This parameter
+ will take effect only after a agent restart or
+ agent reset. This parameter will always be updated
+ in the EEPROM."
+ ::= { snmpAgent 6 }
+
+agentIpNetMask OBJECT-TYPE
+ SYNTAX IpAddress
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The agent's administrative IP subnet mask. The
+ current operational IP subnet mask can be obtained from
+ the ipAdEntMask in the ipAddrTable. This parameter
+ will take effect only after a agent restart or
+ agent reset. This parameter will always be updated
+ in the EEPROM."
+ ::= { snmpAgent 7 }
+
+agentDefaultGateway OBJECT-TYPE
+ SYNTAX IpAddress
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The agent's administrative default gateway IP address.
+ The current operational IP default gateway IP address
+ can be obtained from the ipRouteDest in the ipRouteTable.
+ This parameter will take effect only after a agent restart or
+ agent reset. This parameter will always be updated
+ in the EEPROM."
+ ::= { snmpAgent 8 }
+
+agentPrimaryDnsServer OBJECT-TYPE
+ SYNTAX IpAddress
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " "
+ ::= { snmpAgent 9 }
+
+agentSecondaryDnsServer OBJECT-TYPE
+ SYNTAX IpAddress
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " "
+ ::= { snmpAgent 10 }
+
+agentSnmpServer OBJECT-TYPE
+ SYNTAX INTEGER {
+ off(1),
+ on(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " "
+ ::= { snmpAgent 11 }
+
+agentHttpServer OBJECT-TYPE
+ SYNTAX INTEGER {
+ off(1),
+ on(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " "
+ ::= { snmpAgent 12 }
+
+agentTelnet OBJECT IDENTIFIER ::= { snmpAgent 13 }
+
+agentTelnetServer OBJECT-TYPE
+ SYNTAX INTEGER {
+ off(1),
+ on(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " "
+ ::= { agentTelnet 1 }
+
+agentTelnetIdleTimeouts OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "timeouts is 0 or 60-86400, unit is second, 0: never idle,
+ default is 600"
+ ::= { agentTelnet 2 }
+
+agentTelnetMaxSessions OBJECT-TYPE
+ SYNTAX INTEGER (1..4)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " "
+ ::= { agentTelnet 3 }
+
+agentFtpServer OBJECT-TYPE
+ SYNTAX INTEGER {
+ off(1),
+ on(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " "
+ ::= { snmpAgent 14 }
+
+agentTftpServer OBJECT-TYPE
+ SYNTAX INTEGER {
+ off(1),
+ on(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " "
+ ::= { snmpAgent 15 }
+
+-- the agent trap target group
+
+agentSendTrap OBJECT-TYPE
+ SYNTAX INTEGER {
+ off(1),
+ on(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " "
+ ::= { snmpAgent 16 }
+
+agentTrapTargetTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AgentTrapTargetEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ " "
+ ::= { snmpAgent 17 }
+
+agentTrapTargetEntry OBJECT-TYPE
+ SYNTAX AgentTrapTargetEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ " "
+ INDEX { agentTrapIndex }
+ ::= { agentTrapTargetTable 1 }
+
+AgentTrapTargetEntry ::= SEQUENCE {
+ agentTrapIndex INTEGER,
+ agentTrapTargetIpAddr IpAddress,
+ agentTrapTargetComm DisplayString
+ }
+
+agentTrapIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " "
+ ::= { agentTrapTargetEntry 1 }
+
+agentTrapTargetIpAddr OBJECT-TYPE
+ SYNTAX IpAddress
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " "
+ ::= { agentTrapTargetEntry 2 }
+
+agentTrapTargetComm OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..31))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " "
+ ::= { agentTrapTargetEntry 3 }
+
+-- the agent email alert group
+
+agentEmailAlert OBJECT IDENTIFIER ::= { snmpAgent 18 }
+
+agentSendEmailAlert OBJECT-TYPE
+ SYNTAX INTEGER {
+ off(1),
+ on(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " "
+ ::= { agentEmailAlert 1 }
+
+agentEmailServerIpAddr OBJECT-TYPE
+ SYNTAX IpAddress
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " "
+ ::= { agentEmailAlert 2 }
+
+agentRecipientTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AgentRecipientEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ " "
+ ::= { agentEmailAlert 3 }
+
+agentRecipientEntry OBJECT-TYPE
+ SYNTAX AgentRecipientEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ " "
+ INDEX { agentRecipientIndex }
+ ::= { agentRecipientTable 1 }
+
+AgentRecipientEntry ::= SEQUENCE {
+ agentRecipientIndex INTEGER,
+ agentRecipientEmailAddress DisplayString
+ }
+
+agentRecipientIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " "
+ ::= { agentRecipientEntry 1 }
+
+agentRecipientEmailAddress OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..47))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " "
+ ::= { agentRecipientEntry 2 }
+
+-- the agent syslog group
+
+agentSyslog OBJECT IDENTIFIER ::= { snmpAgent 19 }
+
+agentSyslogOnOff OBJECT-TYPE
+ SYNTAX INTEGER {
+ off(1),
+ on(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " "
+ ::= { agentSyslog 1 }
+
+agentSaveLogsToFlash OBJECT-TYPE
+ SYNTAX INTEGER {
+ off(1),
+ on(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " "
+ ::= { agentSyslog 2 }
+
+agentClearAllLogs OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(1),
+ access(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " "
+ ::= { agentSyslog 3 }
+
+agentSyslogServerTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AgentSyslogServerEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ " "
+ ::= { agentSyslog 4 }
+
+agentSyslogServerEntry OBJECT-TYPE
+ SYNTAX AgentSyslogServerEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ " "
+ INDEX { agentSyslogServerIndex }
+ ::= { agentSyslogServerTable 1 }
+
+AgentSyslogServerEntry ::= SEQUENCE {
+ agentSyslogServerIndex INTEGER,
+ agentSyslogServerIpAddr IpAddress
+ }
+
+agentSyslogServerIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " "
+ ::= { agentSyslogServerEntry 1 }
+
+agentSyslogServerIpAddr OBJECT-TYPE
+ SYNTAX IpAddress
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " "
+ ::= { agentSyslogServerEntry 2 }
+
+-- the agent secure ip group
+
+agentSecureIp OBJECT IDENTIFIER ::= { snmpAgent 20 }
+
+agentSecureIpOnOff OBJECT-TYPE
+ SYNTAX INTEGER {
+ off(1),
+ on(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " "
+ ::= { agentSecureIp 1 }
+
+agentSecureIpTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AgentSecureIpEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ " "
+ ::= { agentSecureIp 2 }
+
+agentSecureIpEntry OBJECT-TYPE
+ SYNTAX AgentSecureIpEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ " "
+ INDEX { agentSecureIpIndex }
+ ::= { agentSecureIpTable 1 }
+
+AgentSecureIpEntry ::= SEQUENCE {
+ agentSecureIpIndex INTEGER,
+ agentSecureIpAddr IpAddress
+ }
+
+agentSecureIpIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " "
+ ::= { agentSecureIpEntry 1 }
+
+agentSecureIpAddr OBJECT-TYPE
+ SYNTAX IpAddress
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " "
+ ::= { agentSecureIpEntry 2 }
+
+-- the agent ntp group
+
+agentTime OBJECT IDENTIFIER ::= { snmpAgent 21 }
+
+agentNtpClientOnOff OBJECT-TYPE
+ SYNTAX INTEGER {
+ off(1),
+ on(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " "
+ ::= { agentTime 1 }
+
+agentNtpServerIpAddr OBJECT-TYPE
+ SYNTAX IpAddress
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " "
+ ::= { agentTime 2 }
+
+agentNtpUpdateInterval OBJECT-TYPE
+ SYNTAX INTEGER (60..86400)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "unit is second"
+ ::= { agentTime 3 }
+
+agentTimeZoneName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..8))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " "
+ ::= { agentTime 4 }
+
+agentTimeZoneHoursOffsetWithGMT OBJECT-TYPE
+ SYNTAX INTEGER (-23..23)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " "
+ ::= { agentTime 5 }
+
+agentTimeZoneMinutesOffsetWithGMT OBJECT-TYPE
+ SYNTAX INTEGER (0..59)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " "
+ ::= { agentTime 6 }
+
+agentSummerTime OBJECT-TYPE
+ SYNTAX INTEGER {
+ summer(1),
+ Sun(2),
+ lastSun(3),
+ manual(4)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " "
+ ::= { agentTime 7 }
+
+agentSummerTimeBeginMonth OBJECT-TYPE
+ SYNTAX INTEGER {
+ jan(1),
+ feb(2),
+ mar(3),
+ apr(4),
+ may(5),
+ jun(6),
+ jul(7),
+ aug(8),
+ sep(9),
+ oct(10),
+ nov(11),
+ dec(12)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " "
+ ::= { agentTime 8 }
+
+agentSummerTimeBeginNth OBJECT-TYPE
+ SYNTAX INTEGER {
+ first(1),
+ second(2),
+ third(3),
+ fourth(4),
+ last(5)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " "
+ ::= { agentTime 9 }
+
+agentSummerTimeBeginWeekday OBJECT-TYPE
+ SYNTAX INTEGER {
+ sun(1),
+ mon(2),
+ tue(3),
+ wed(4),
+ thu(5),
+ fri(6),
+ sat(7)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " "
+ ::= { agentTime 10 }
+
+agentSummerTimeBeginHour OBJECT-TYPE
+ SYNTAX INTEGER (0..23)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " "
+ ::= { agentTime 11 }
+
+agentSummerTimeBeginMinute OBJECT-TYPE
+ SYNTAX INTEGER (0..59)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " "
+ ::= { agentTime 12 }
+
+agentSummerTimeEndMonth OBJECT-TYPE
+ SYNTAX INTEGER {
+ jan(1),
+ feb(2),
+ mar(3),
+ apr(4),
+ may(5),
+ jun(6),
+ jul(7),
+ aug(8),
+ sep(9),
+ oct(10),
+ nov(11),
+ dec(12)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " "
+ ::= { agentTime 13 }
+
+agentSummerTimeEndNth OBJECT-TYPE
+ SYNTAX INTEGER {
+ first(1),
+ second(2),
+ third(3),
+ fourth(4),
+ last(5)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " "
+ ::= { agentTime 14 }
+
+agentSummerTimeEndWeekday OBJECT-TYPE
+ SYNTAX INTEGER {
+ sun(1),
+ mon(2),
+ tue(3),
+ wed(4),
+ thu(5),
+ fri(6),
+ sat(7)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " "
+ ::= { agentTime 15 }
+
+agentSummerTimeEndHour OBJECT-TYPE
+ SYNTAX INTEGER (0..23)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " "
+ ::= { agentTime 16 }
+
+agentSummerTimeEndMinute OBJECT-TYPE
+ SYNTAX INTEGER (0..59)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " "
+ ::= { agentTime 17 }
+
+agentSaveRunningCfg OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(1),
+ saveConfiguration(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Set this variable will save current configuration.
+ the value will be reset to 1 after succeed."
+ ::= { snmpAgent 22 }
+
+agentDefault OBJECT IDENTIFIER ::= { snmpAgent 23 }
+
+agentKeepCurrentIP OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(1),
+ keepCurrentIP(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Set this variable will keep current IP configuration
+ (IP address, Subnet Mask, Default Gateway and Domain Name Servers).
+ the value will be reset to 1 after succeed."
+ ::= { agentDefault 1 }
+
+agentKeepCurrentSNMP OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(1),
+ keepCurrentSNMP(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Set this variable will keep current SNMP settings
+ (System information, SNMP communities and SNMP Trap information).
+ the value will be reset to 1 after succeed."
+ ::= { agentDefault 2 }
+
+agentKeepCurrentPort OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(1),
+ keepCurrentPort(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Set this variable will keep current port settings.
+ the value will be reset to 1 after succeed."
+ ::= { agentDefault 3 }
+
+agentKeepCurrentUser OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(1),
+ keepCurrentUser(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Set this variable will keep current User settings.
+ the value will be reset to 1 after succeed."
+ ::= { agentDefault 4 }
+
+agentFactoryDefault OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(1),
+ factoryDefault(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Set this variable will use factory default configuration and reload.
+ the value will be reset to 1 after succeed."
+ ::= { agentDefault 5 }
+
+agentReloadSystem OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(1),
+ reloadSystem(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Set this variable will reload system.
+ the value will be reset to 1 after succeed."
+ ::= { snmpAgent 24 }
+
+agentTftpUpgrade OBJECT IDENTIFIER ::= { snmpAgent 25 }
+
+agentTftpServerIpAddr OBJECT-TYPE
+ SYNTAX IpAddress
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specify the IP address of the TFTP server where the binary
+ code is stored."
+ ::= { agentTftpUpgrade 1 }
+
+agentUpgradeFileName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..31))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specify the file name of the binary code to be upgraded."
+ ::= { agentTftpUpgrade 2 }
+
+agentUpgradeState OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(1),
+ start(2),
+ inProgress(3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Set the variable 1 will start the upgrade process."
+ ::= { agentTftpUpgrade 3 }
+
+-- system
+
+systemTemperature OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ ::= { lambdatrail 1 }
+
+systemPower1 OBJECT-TYPE
+ SYNTAX INTEGER {
+ notplugged(1),
+ off(2),
+ on(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ ::= { lambdatrail 2 }
+
+systemPower2 OBJECT-TYPE
+ SYNTAX INTEGER {
+ notplugged(1),
+ off(2),
+ on(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ ::= { lambdatrail 3 }
+
+systemFan1 OBJECT-TYPE
+ SYNTAX INTEGER {
+ failure(1),
+ off(2),
+ on(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ ::= { lambdatrail 4 }
+
+systemFan1Selection OBJECT-TYPE
+ SYNTAX INTEGER {
+ alwaysOff(1),
+ alwaysOn(2),
+ byTemperature(3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ ::= { lambdatrail 5 }
+
+systemFan1OnTemperature OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ ::= { lambdatrail 6 }
+
+systemFan1OffTemperature OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ ::= { lambdatrail 7 }
+
+systemFan2 OBJECT-TYPE
+ SYNTAX INTEGER {
+ failure(1),
+ off(2),
+ on(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ ::= { lambdatrail 8 }
+
+systemFan2Selection OBJECT-TYPE
+ SYNTAX INTEGER {
+ alwaysOff(1),
+ alwaysOn(2),
+ byTemperature(3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ ::= { lambdatrail 9 }
+
+systemFan2OnTemperature OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ ::= { lambdatrail 10 }
+
+systemFan2OffTemperature OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ ::= { lambdatrail 11 }
+
+-- port table
+
+portTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PortEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of interface entries."
+ ::= { lambdatrail 12 }
+
+portEntry OBJECT-TYPE
+ SYNTAX PortEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A port entry containing objects
+ below for a port."
+ INDEX { portId }
+ ::= { portTable 1 }
+
+PortEntry ::= SEQUENCE {
+ portId INTEGER,
+ portLicensed INTEGER,
+ portEnabled INTEGER,
+ portAPSD INTEGER,
+ portLinePlugged INTEGER,
+ portLineLink INTEGER,
+ portLineWavelength INTEGER,
+ portLineTxPower INTEGER,
+ portLineRxPower INTEGER,
+ portLineLaserTemp INTEGER,
+ portLineLaserBias INTEGER,
+ portClientPlugged INTEGER,
+ portClientLink INTEGER,
+ portClientWavelength INTEGER,
+ portClientTxPower INTEGER,
+ portClientRxPower INTEGER,
+ portClientLaserTemp INTEGER,
+ portClientLaserBias INTEGER,
+ portName DisplayString
+ }
+
+portId OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A unique value for each interface."
+ ::= { portEntry 1 }
+
+portLicensed OBJECT-TYPE
+ SYNTAX INTEGER {
+ no(1),
+ yes(2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ ::= { portEntry 2 }
+
+portEnabled OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(1),
+ enabled(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ ::= { portEntry 3 }
+
+portAPSD OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(1),
+ enabled(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ ::= { portEntry 4 }
+
+portLinePlugged OBJECT-TYPE
+ SYNTAX INTEGER {
+ notPlugged(1),
+ plugged(2),
+ notAvailable(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ ::= { portEntry 5 }
+
+portLineLink OBJECT-TYPE
+ SYNTAX INTEGER {
+ down(1),
+ up(2),
+ notAvailable(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ ::= { portEntry 6 }
+
+portLineWavelength OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "unit is nanometer, -1 means not available"
+ ::= { portEntry 7 }
+
+portLineTxPower OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "unit is 1/1000 dBm, for example, 1234 means 1.234 dBm, -1234 means -1.234dBm, -1 means not available"
+ ::= { portEntry 8 }
+
+portLineRxPower OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "unit is 1/1000 dBm, for example, 1234 means 1.234 dBm, -1234 means -1.234dBm, -1 means not available"
+ ::= { portEntry 9 }
+
+portLineLaserTemp OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "unit is Celsius degree, -1 means not available"
+ ::= { portEntry 10 }
+
+portLineLaserBias OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "unit is mini ampere, -1 means not available"
+ ::= { portEntry 11 }
+
+portClientPlugged OBJECT-TYPE
+ SYNTAX INTEGER {
+ notPlugged(1),
+ plugged(2),
+ notAvailable(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ ::= { portEntry 12 }
+
+portClientLink OBJECT-TYPE
+ SYNTAX INTEGER {
+ down(1),
+ up(2),
+ notAvailable (3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ ::= { portEntry 13 }
+
+portClientWavelength OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "unit is nanometer, -1 means not available"
+ ::= { portEntry 14 }
+
+portClientTxPower OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "unit is 1/1000 dBm, for example, 1234 means 1.234 dBm, -1234 means -1.234dBm, -1 means not available"
+ ::= { portEntry 15 }
+
+portClientRxPower OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "unit is 1/1000 dBm, for example, 1234 means 1.234 dBm, -1234 means -1.234dBm, -1 means not available"
+ ::= { portEntry 16 }
+
+portClientLaserTemp OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "unit is Celsius degree, -1 means not available"
+ ::= { portEntry 17 }
+
+portClientLaserBias OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "unit is mini ampere, -1 means not available"
+ ::= { portEntry 18 }
+
+portName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..31))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ ::= { portEntry 19 }
+
+--
+
+usablePorts OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ ::= { lambdatrail 13 }
+
+END
diff --git a/MIBS/deltanet/Lambdatrail2s-MIB b/MIBS/deltanet/Lambdatrail2s-MIB
new file mode 100644
index 0000000..abbd616
--- /dev/null
+++ b/MIBS/deltanet/Lambdatrail2s-MIB
@@ -0,0 +1,1143 @@
+Lambdatrail2s-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ OBJECT-TYPE, NOTIFICATION-TYPE, MODULE-IDENTITY, Integer32,
+ IpAddress
+ FROM SNMPv2-SMI
+ DisplayString
+ FROM SNMPv2-TC
+ MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
+ FROM SNMPv2-CONF
+ deltanet
+ FROM Deltanet-MIB;
+
+lambdatrail2s MODULE-IDENTITY
+ LAST-UPDATED "201502100000Z"
+ ORGANIZATION "DeltaNet AG Switzerland"
+ CONTACT-INFO "http://www.deltanet.ch"
+ DESCRIPTION "The MIB module for managing Deltanet Lambdatrail2-S device.
+ Needs firmware 1.1.0 or higher."
+ REVISION "201502100000Z"
+ DESCRIPTION "TFTP-Server removed"
+ REVISION "201501200000Z"
+ DESCRIPTION "Adjust structure to be common"
+ REVISION "201501150000Z"
+ DESCRIPTION "Initial Lambdatrail2-S Version"
+ ::= { deltanet 5 }
+
+-- Deltanet AG Specific Objects --
+lt2sNotifications OBJECT IDENTIFIER ::= { lambdatrail2s 0 }
+lt2sAgent OBJECT IDENTIFIER ::= { lambdatrail2s 1 }
+lt2sSystem OBJECT IDENTIFIER ::= { lambdatrail2s 2 }
+lt2sPorts OBJECT IDENTIFIER ::= { lambdatrail2s 3 }
+lt2sInfo OBJECT IDENTIFIER ::= { lambdatrail2s 4 }
+lt2sCompliances OBJECT IDENTIFIER ::= { lambdatrail2s 8 }
+lt2sGroups OBJECT IDENTIFIER ::= { lambdatrail2s 9 }
+
+
+-- LT3 agent --
+lt2sDescription OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (1..63))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Shows the System Description."
+ ::= { lt2sAgent 1 }
+
+lt2sDeviceType OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (1..16))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Shows the Device Type."
+ ::= { lt2sAgent 2 }
+
+lt2sHwRevision OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (1..16))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Shows the Device Type."
+ ::= { lt2sAgent 3 }
+
+lt2sManufacturingDate OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (1..16))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Shows the Device Type."
+ ::= { lt2sAgent 4 }
+
+lt2sSerialNumber OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (1..16))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Shows the serial number of the device."
+ ::= { lt2sAgent 5 }
+
+lt2sSystemName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..63))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The assigned system name."
+ ::= { lt2sAgent 6 }
+
+lt2sSystemLocation OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..63))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "System location."
+ ::= { lt2sAgent 7 }
+
+lt2sSystemContact OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..63))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The responsible person."
+ ::= { lt2sAgent 8 }
+
+lt2sSystemUptime OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (1..31))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Shows the time since the last restart of the
+ management agent."
+ ::= { lt2sAgent 9 }
+
+lt2sFirmwareVersion OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (1..63))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Shows the software version of the agent running image."
+ ::= { lt2sAgent 10 }
+
+lt2suCVersion OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (1..63))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Shows the firmware version of the micro controller."
+ ::= { lt2sAgent 11 }
+
+lt2sSaveRunningCfg OBJECT-TYPE
+ SYNTAX INTEGER { none(1), saveConfig(2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Set this variable will save current configuration.
+ The value is set back to 1 after succeed."
+ ::= { lt2sAgent 12 }
+
+lt2sResetAgent OBJECT-TYPE
+ SYNTAX INTEGER { none(1), resetAgent(2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Set this variable will reset the agent.
+ The value is set back to 1 after reset."
+ ::= { lt2sAgent 13 }
+
+lt2sSnmpGetCommunity OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..63))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The get community, read only."
+ ::= { lt2sAgent 14 }
+
+lt2sSnmpSetCommunity OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..63))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The set community, read/write."
+ ::= { lt2sAgent 15 }
+
+lt2sIp4DHCP OBJECT-TYPE
+ SYNTAX INTEGER { off(1), on(2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "DHCP enable or disable. Default is off"
+ ::= { lt2sAgent 16 }
+
+lt2sIp4Address OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The agent's administrative IP address. The
+ current operational IP address can be obtained from
+ the ipAdEntAddr in the ipAddrTable. This parameter
+ will take effect only after a agent restart or
+ agent reset. This parameter will always be updated
+ in the EEPROM."
+ ::= { lt2sAgent 17 }
+
+lt2sIp4Mask OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The agent's administrative IP subnet mask. The
+ current operational IP subnet mask can be obtained from
+ the ipAdEntMask in the ipAddrTable. This parameter
+ will take effect only after a agent restart or
+ agent reset. This parameter will always be updated
+ in the EEPROM."
+ ::= { lt2sAgent 18 }
+
+lt2sIp4Gateway OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The agent's administrative default gateway IP address.
+ The current operational IP default gateway IP address
+ can be obtained from the ipRouteDest in the ipRouteTable.
+ This parameter will take effect only after a agent restart or
+ agent reset. This parameter will always be updated
+ in the EEPROM."
+ ::= { lt2sAgent 19 }
+
+lt2sIp4PrimaryDns OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "First DNS server address."
+ ::= { lt2sAgent 20 }
+
+lt2sIp4SecondaryDns OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Second DNS server address."
+ ::= { lt2sAgent 21 }
+
+lt2sSnmpServer OBJECT-TYPE
+ SYNTAX INTEGER { off(1), on(2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION " "
+ ::= { lt2sAgent 22 }
+
+lt2sHttpServer OBJECT-TYPE
+ SYNTAX INTEGER { off(1), on(2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION " "
+ ::= { lt2sAgent 23 }
+
+lt2sTelnetServer OBJECT-TYPE
+ SYNTAX INTEGER { off(1), on(2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION " "
+ ::= { lt2sAgent 24 }
+
+lt2sFtpServer OBJECT-TYPE
+ SYNTAX INTEGER { off(1), on(2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION " "
+ ::= { lt2sAgent 25 }
+
+-- Management port definitions --
+lt2sMgmtPortTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Lt2sMgmtPortEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "A list of management port entries."
+ ::= { lt2sAgent 26 }
+
+lt2sMgmtPortEntry OBJECT-TYPE
+ SYNTAX Lt2sMgmtPortEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "An entry containing information applicable to
+ the management ports."
+ INDEX { lt2sMgmtPortId }
+ ::= { lt2sMgmtPortTable 1 }
+
+Lt2sMgmtPortEntry ::= SEQUENCE {
+ lt2sMgmtPortId Integer32,
+ lt2sMgmtPortName DisplayString,
+ lt2sMgmtPortEnable INTEGER,
+ lt2sMgmtPortLink INTEGER,
+ lt2sMgmtPortSpeed INTEGER,
+ lt2sMgmtPortTxBytes Integer32,
+ lt2sMgmtPortRxBytes Integer32,
+ lt2sMgmtSfpPlugged INTEGER,
+ lt2sMgmtSfpVendor DisplayString,
+ lt2sMgmtSfpType DisplayString,
+ lt2sMgmtSfpSerial DisplayString,
+ lt2sMgmtSfpWavelength DisplayString,
+ lt2sMgmtSfpTxPower Integer32,
+ lt2sMgmtSfpRxPower Integer32,
+ lt2sMgmtSfpLaserTemp Integer32,
+ lt2sMgmtSfpLaserBias Integer32,
+ lt2sMgmtSfpTxLow Integer32,
+ lt2sMgmtSfpTxHigh Integer32,
+ lt2sMgmtSfpRxLow Integer32,
+ lt2sMgmtSfpRxHigh Integer32 }
+
+lt2sMgmtPortId OBJECT-TYPE
+ SYNTAX Integer32 (1..3)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The management port identification.
+ 1 Inband SFP, 2 LAN1, 3 LAN2."
+ ::= { lt2sMgmtPortEntry 1 }
+
+lt2sMgmtPortName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The name of the management port"
+ ::= { lt2sMgmtPortEntry 2 }
+
+lt2sMgmtPortEnable OBJECT-TYPE
+ SYNTAX INTEGER { disabled(1), enabled(2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The enabled state of the port."
+ ::= { lt2sMgmtPortEntry 3 }
+
+lt2sMgmtPortLink OBJECT-TYPE
+ SYNTAX INTEGER { down(1), up(2), notAvailable(3) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The link state of the management port."
+ ::= { lt2sMgmtPortEntry 4 }
+
+lt2sMgmtPortSpeed OBJECT-TYPE
+ SYNTAX INTEGER { full1000(1), full100(2), half100(3),
+ full10(4), half10(5), notAvailable(6) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The speed mode of the port."
+ ::= { lt2sMgmtPortEntry 5 }
+
+lt2sMgmtPortTxBytes OBJECT-TYPE
+ SYNTAX Integer32 (0..2147483647)
+ UNITS "sent Bytes"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The total amount of sent bytes."
+ ::= { lt2sMgmtPortEntry 6 }
+
+lt2sMgmtPortRxBytes OBJECT-TYPE
+ SYNTAX Integer32 (0..2147483647)
+ UNITS "sent Bytes"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The total amount of received bytes."
+ ::= { lt2sMgmtPortEntry 7 }
+
+lt2sMgmtSfpPlugged OBJECT-TYPE
+ SYNTAX INTEGER { removed(1), inserted(2), notAvailable(3) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The line SFP plugged state of the port."
+ ::= { lt2sMgmtPortEntry 8 }
+
+lt2sMgmtSfpVendor OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..16))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The vendor name of the SFP."
+ ::= { lt2sMgmtPortEntry 9 }
+
+lt2sMgmtSfpType OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..16))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The vendor part name of the SFP."
+ ::= { lt2sMgmtPortEntry 10 }
+
+lt2sMgmtSfpSerial OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..16))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The serial number of the SFP."
+ ::= { lt2sMgmtPortEntry 11 }
+
+lt2sMgmtSfpWavelength OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..31))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The SFP wavelength of the port. If the SFP
+ is removed the object contains 'NA'."
+ ::= { lt2sMgmtPortEntry 12 }
+
+lt2sMgmtSfpTxPower OBJECT-TYPE
+ SYNTAX Integer32 (-1 | 0..2147483647)
+ UNITS "0.001 dBm"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The SFP transmit power of the port. If the SFP
+ is removed, the value is -1."
+ ::= { lt2sMgmtPortEntry 13 }
+
+lt2sMgmtSfpRxPower OBJECT-TYPE
+ SYNTAX Integer32 (-1 | 0..2147483647)
+ UNITS "0.001 dBm"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The SFP receive power of the port. If the SFP
+ is removed, the value is -1."
+ ::= { lt2sMgmtPortEntry 14 }
+
+lt2sMgmtSfpLaserTemp OBJECT-TYPE
+ SYNTAX Integer32 (-1 | 0..2147483647)
+ UNITS "0.01 degrees Celsius"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The internal temperature of the SFP. If the SFP
+ is removed, the value is -1."
+ ::= { lt2sMgmtPortEntry 15 }
+
+lt2sMgmtSfpLaserBias OBJECT-TYPE
+ SYNTAX Integer32 (-1 | 0..2147483647)
+ UNITS "0.001 Ampere"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The SFP laser bias in milli ampere. If the SFP
+ is removed, the value is -1."
+ ::= { lt2sMgmtPortEntry 16 }
+
+lt2sMgmtSfpTxLow OBJECT-TYPE
+ SYNTAX Integer32 (-10..2)
+ UNITS "dBm"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The SFP laser TX low threshold in dBm."
+ ::= { lt2sMgmtPortEntry 17 }
+
+lt2sMgmtSfpTxHigh OBJECT-TYPE
+ SYNTAX Integer32 (-4..8)
+ UNITS "dBm"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The SFP laser TX high threshold in dBm."
+ ::= { lt2sMgmtPortEntry 18 }
+
+lt2sMgmtSfpRxLow OBJECT-TYPE
+ SYNTAX Integer32 (-30..0)
+ UNITS "dBm"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The SFP laser RX low threshold in dBm."
+ ::= { lt2sMgmtPortEntry 19 }
+
+lt2sMgmtSfpRxHigh OBJECT-TYPE
+ SYNTAX Integer32 (-12..6)
+ UNITS "dBm"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The SFP laser RX high threshold in dBm."
+ ::= { lt2sMgmtPortEntry 20 }
+
+
+ -- LT3 system --
+lt2sTemperature OBJECT-TYPE
+ SYNTAX Integer32 ( 0..80 )
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Shows the ambient temperature."
+ ::= { lt2sSystem 1 }
+
+lt2sPowerType OBJECT-TYPE
+ SYNTAX INTEGER { ac(1), dc(2), notAvailable(3) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The device's power supply 1 type."
+ ::= { lt2sSystem 2 }
+
+lt2sPowerStatus OBJECT-TYPE
+ SYNTAX INTEGER { normal(1), failed(2), notPlugged(3) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The device's power supply 1 status."
+ ::= { lt2sSystem 3 }
+
+lt2sPowerFanStatus OBJECT-TYPE
+ SYNTAX INTEGER { failed(1), on(2), off(3) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The device's power supply 1's fan status."
+ ::= { lt2sSystem 4 }
+
+lt2sPowerFanRPM OBJECT-TYPE
+ SYNTAX Integer32 (0..20000)
+ UNITS "revolutions per minute"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The device's power supply 1's fan rounds per minute."
+ ::= { lt2sSystem 5 }
+
+lt2sPowerFanMode OBJECT-TYPE
+ SYNTAX INTEGER { alwaysOff(1), alwaysOn(2), byTemperature(3) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The device's power supply 1's fan mode."
+ ::= { lt2sSystem 6 }
+
+lt2sPowerFanOnTemp OBJECT-TYPE
+ SYNTAX Integer32 (10..60)
+ UNITS "degrees Celsius"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The device's power supply 1's fan on temperature."
+ ::= { lt2sSystem 7 }
+
+lt2sPowerFanOffTemp OBJECT-TYPE
+ SYNTAX Integer32 (10..60)
+ UNITS "degrees Celsius"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The device's power supply 1's fan off temperature."
+ ::= { lt2sSystem 8 }
+
+
+-- LT2-S Ports Section --
+lt2sPortTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Lt2sPortEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "A list of port table entries."
+ ::= { lt2sPorts 1 }
+
+lt2sPortEntry OBJECT-TYPE
+ SYNTAX Lt2sPortEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "An entry containing information applicable to a
+ particular port."
+ INDEX { lt2sPortId }
+ ::= { lt2sPortTable 1 }
+
+Lt2sPortEntry ::= SEQUENCE {
+ lt2sPortId Integer32,
+ lt2sPortEnable INTEGER,
+ lt2sPortApsd INTEGER,
+ lt2sPortSpeed INTEGER,
+ lt2sPortReset INTEGER,
+ lt2sPortLoop INTEGER,
+ lt2sPortName DisplayString,
+ lt2sLinePlugged INTEGER,
+ lt2sLineLink INTEGER,
+ lt2sLineApsd INTEGER,
+ lt2sLineType DisplayString,
+ lt2sLineWavelength DisplayString,
+ lt2sLineTxPower Integer32,
+ lt2sLineRxPower Integer32,
+ lt2sLineLaserTemp Integer32,
+ lt2sLineLaserBias Integer32,
+ lt2sLineTxLow Integer32,
+ lt2sLineTxHigh Integer32,
+ lt2sLineRxLow Integer32,
+ lt2sLineRxHigh Integer32,
+ lt2sClientPlugged INTEGER,
+ lt2sClientLink INTEGER,
+ lt2sClientApsd INTEGER,
+ lt2sClientType DisplayString,
+ lt2sClientWavelength DisplayString,
+ lt2sClientTxPower Integer32,
+ lt2sClientRxPower Integer32,
+ lt2sClientLaserTemp Integer32,
+ lt2sClientLaserBias Integer32,
+ lt2sClientTxLow Integer32,
+ lt2sClientTxHigh Integer32,
+ lt2sClientRxLow Integer32,
+ lt2sClientRxHigh Integer32 }
+
+lt2sPortId OBJECT-TYPE
+ SYNTAX Integer32 (1)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "A unique value for each port."
+ ::= { lt2sPortEntry 1 }
+
+lt2sPortEnable OBJECT-TYPE
+ SYNTAX INTEGER { disable(1), enable(2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The status of the port."
+ ::= { lt2sPortEntry 2 }
+
+lt2sPortApsd OBJECT-TYPE
+ SYNTAX INTEGER { disabled(1), enabled(2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The automatic power shut down configuration of the port."
+ ::= { lt2sPortEntry 3 }
+
+lt2sPortSpeed OBJECT-TYPE
+ SYNTAX INTEGER { transparent(1), speed10g(2), speed8g(3), speed16g(4) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The speed mode of the port."
+ ::= { lt2sPortEntry 4 }
+
+lt2sPortReset OBJECT-TYPE
+ SYNTAX INTEGER { no(1), yes(2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Reset the port."
+ ::= { lt2sPortEntry 5 }
+
+lt2sPortLoop OBJECT-TYPE
+ SYNTAX INTEGER { off(1), line(2), client(3) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Set Loop on chosen port."
+ ::= { lt2sPortEntry 6 }
+
+lt2sPortName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..31))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The name of the port."
+ ::= { lt2sPortEntry 7 }
+
+lt2sLinePlugged OBJECT-TYPE
+ SYNTAX INTEGER { notPlugged(1), plugged(2), notAvailable(3) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The line SFP plugged state of the port."
+ ::= { lt2sPortEntry 8 }
+
+lt2sLineLink OBJECT-TYPE
+ SYNTAX INTEGER { down(1), up(2), notAvailable(3) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The line SFP link state of the port."
+ ::= { lt2sPortEntry 9 }
+
+lt2sLineApsd OBJECT-TYPE
+ SYNTAX INTEGER { no(1), yes(2), disabled(3), notAvailable(4) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The automatic power shut down state of the line port."
+ ::= { lt2sPortEntry 10 }
+
+lt2sLineType OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..31))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The line SFP type of the port."
+ ::= { lt2sPortEntry 11 }
+
+lt2sLineWavelength OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..31))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The line SFP wavelength of the port. If the line SFP is not
+ plugged in, the object should contain the value of 'NA'."
+ ::= { lt2sPortEntry 12 }
+
+lt2sLineTxPower OBJECT-TYPE
+ SYNTAX Integer32 (-1 | 0..2147483647)
+ UNITS "0.001 dBm"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The line SFP transmit power of the port. If the line SFP
+ is not plugged in, the object should contain the value of -1."
+ ::= { lt2sPortEntry 13 }
+
+lt2sLineRxPower OBJECT-TYPE
+ SYNTAX Integer32 (-1 | 0..2147483647)
+ UNITS "0.001 dBm"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The line SFP receive power of the port. If the line SFP
+ is not plugged in, the object should contain the value of -1."
+ ::= { lt2sPortEntry 14 }
+
+lt2sLineLaserTemp OBJECT-TYPE
+ SYNTAX Integer32 (-1 | 0..2147483647)
+ UNITS "degrees Centigrade"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The line SFP laser temperature of the port. If the line SFP
+ is not plugged in, the object should contain the value of -1."
+ ::= { lt2sPortEntry 15 }
+
+lt2sLineLaserBias OBJECT-TYPE
+ SYNTAX Integer32 (-1 | 0..2147483647)
+ UNITS "0.001 Amp"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The line SFP laser bias of the port. If the line SFP
+ is not plugged in, the object should contain the value of -1."
+ ::= { lt2sPortEntry 16 }
+
+lt2sLineTxLow OBJECT-TYPE
+ SYNTAX Integer32 (-10..2)
+ UNITS "dBm"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The line SFP laser TX low threshold of the port."
+ ::= { lt2sPortEntry 17 }
+
+lt2sLineTxHigh OBJECT-TYPE
+ SYNTAX Integer32 (-4..8)
+ UNITS "dBm"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The line SFP laser TX high threshold of the port."
+ ::= { lt2sPortEntry 18 }
+
+lt2sLineRxLow OBJECT-TYPE
+ SYNTAX Integer32 (-30..0)
+ UNITS "dBm"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The line SFP laser RX low threshold of the port."
+ ::= { lt2sPortEntry 19 }
+
+lt2sLineRxHigh OBJECT-TYPE
+ SYNTAX Integer32 (-12..6)
+ UNITS "dBm"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The line SFP laser RX high threshold of the port."
+ ::= { lt2sPortEntry 20 }
+
+lt2sClientPlugged OBJECT-TYPE
+ SYNTAX INTEGER { notPlugged(1), plugged(2), notAvailable(3) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The client SFP plugged state of the port."
+ ::= { lt2sPortEntry 21 }
+
+lt2sClientLink OBJECT-TYPE
+ SYNTAX INTEGER { down(1), up(2), notAvailable(3) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The client SFP link state of the port."
+ ::= { lt2sPortEntry 22 }
+
+lt2sClientApsd OBJECT-TYPE
+ SYNTAX INTEGER { no(1), yes(2), disabled(3), notAvailable(4) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The automatic power shut down state of the client port."
+ ::= { lt2sPortEntry 23 }
+
+lt2sClientType OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..31))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The client SFP type of the port."
+ ::= { lt2sPortEntry 24 }
+
+lt2sClientWavelength OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..31))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The client SFP wavelength of the port. If the client SFP
+ is not plugged in, the object should contain the value of 'NA'."
+ ::= { lt2sPortEntry 25 }
+
+lt2sClientTxPower OBJECT-TYPE
+ SYNTAX Integer32 (-1 | 0..2147483647)
+ UNITS "0.001 dBm"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The client SFP transmit power of the port. If the client SFP
+ is not plugged in, the object should contain the value of -1."
+ ::= { lt2sPortEntry 26 }
+
+lt2sClientRxPower OBJECT-TYPE
+ SYNTAX Integer32 (-1 | 0..2147483647)
+ UNITS "0.001 dBm"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The client SFP receive power of the port. If the client SFP
+ is not plugged in, the object should contain the value of -1."
+ ::= { lt2sPortEntry 27 }
+
+lt2sClientLaserTemp OBJECT-TYPE
+ SYNTAX Integer32 (-1 | 0..2147483647)
+ UNITS "degrees Centigrade"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The client SFP laser temperature of the port. If the client SFP
+ is not plugged in, the object should contain the value of -1."
+ ::= { lt2sPortEntry 28 }
+
+lt2sClientLaserBias OBJECT-TYPE
+ SYNTAX Integer32 (-1 | 0..2147483647)
+ UNITS "0.001 Amp"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The client SFP laser bias of the port. If the client SFP
+ is not plugged in, the object should contain the value of -1."
+ ::= { lt2sPortEntry 29 }
+
+lt2sClientTxLow OBJECT-TYPE
+ SYNTAX Integer32 (-10..2)
+ UNITS "dBm"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The client SFP laser TX low threshold of the port."
+ ::= { lt2sPortEntry 30 }
+
+lt2sClientTxHigh OBJECT-TYPE
+ SYNTAX Integer32 (-4..8)
+ UNITS "dBm"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The client SFP laser TX high threshold of the port."
+ ::= { lt2sPortEntry 31 }
+
+lt2sClientRxLow OBJECT-TYPE
+ SYNTAX Integer32 (-30..0)
+ UNITS "dBm"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The client SFP laser RX low threshold of the port."
+ ::= { lt2sPortEntry 32 }
+
+lt2sClientRxHigh OBJECT-TYPE
+ SYNTAX Integer32 (-12..6)
+ UNITS "dBm"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The client SFP laser RX high threshold of the port."
+ ::= { lt2sPortEntry 33 }
+
+
+-- LT2-S Trap Information --
+lt2sTrapDetails OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The trap description."
+ ::= { lt2sInfo 1 }
+
+-- LT2-S Trap Section --
+lt2sMgmtStartup NOTIFICATION-TYPE
+ OBJECTS { lt2sTrapDetails }
+ STATUS current
+ DESCRIPTION "The agent has started up and is running."
+ ::= { lt2sNotifications 1 }
+
+lt2sMgmtAuthenticationFailure NOTIFICATION-TYPE
+ OBJECTS { lt2sTrapDetails }
+ STATUS current
+ DESCRIPTION "Login has failed."
+ ::= { lt2sNotifications 2 }
+
+lt2sTemperatureHigh NOTIFICATION-TYPE
+ OBJECTS { lt2sTrapDetails }
+ STATUS current
+ DESCRIPTION "Device temperature is high."
+ ::= { lt2sNotifications 3 }
+
+lt2sTemperatureNormal NOTIFICATION-TYPE
+ OBJECTS { lt2sTrapDetails }
+ STATUS current
+ DESCRIPTION "Device temperature is back to normal.
+ Lower than 40 degrees celsius."
+ ::= { lt2sNotifications 4 }
+
+lt2sPowerSupplyPluggedIn NOTIFICATION-TYPE
+ OBJECTS { lt2sTrapDetails }
+ STATUS current
+ DESCRIPTION "A power is plugged in."
+ ::= { lt2sNotifications 5 }
+
+lt2sPowerSupplyPluggedOut NOTIFICATION-TYPE
+ OBJECTS { lt2sTrapDetails }
+ STATUS current
+ DESCRIPTION "A power is plugged out."
+ ::= { lt2sNotifications 6 }
+
+lt2sPowerNormal NOTIFICATION-TYPE
+ OBJECTS { lt2sTrapDetails }
+ STATUS current
+ DESCRIPTION "A power goes on."
+ ::= { lt2sNotifications 7 }
+
+lt2sPowerFailure NOTIFICATION-TYPE
+ OBJECTS { lt2sTrapDetails }
+ STATUS current
+ DESCRIPTION "A power goes off."
+ ::= { lt2sNotifications 8 }
+
+lt2sFanOn NOTIFICATION-TYPE
+ OBJECTS { lt2sTrapDetails }
+ STATUS current
+ DESCRIPTION "A fan goes on."
+ ::= { lt2sNotifications 9 }
+
+lt2sFanOff NOTIFICATION-TYPE
+ OBJECTS { lt2sTrapDetails }
+ STATUS current
+ DESCRIPTION "A fan goes off."
+ ::= { lt2sNotifications 10 }
+
+lt2sFanFailure NOTIFICATION-TYPE
+ OBJECTS { lt2sTrapDetails }
+ STATUS current
+ DESCRIPTION "A fan goes to failure."
+ ::= { lt2sNotifications 11 }
+
+lt2sMgmtSfpPluggedIn NOTIFICATION-TYPE
+ OBJECTS { lt2sMgmtPortId, lt2sTrapDetails, lt2sMgmtPortName }
+ STATUS current
+ DESCRIPTION "SFP transceiver is plugged in on management port."
+ ::= { lt2sNotifications 12 }
+
+lt2sMgmtSfpPluggedOut NOTIFICATION-TYPE
+ OBJECTS { lt2sMgmtPortId, lt2sTrapDetails, lt2sMgmtPortName }
+ STATUS current
+ DESCRIPTION "SFP transceiver is plugged out on management port."
+ ::= { lt2sNotifications 13 }
+
+lt2sMgmtLinkUp NOTIFICATION-TYPE
+ OBJECTS { lt2sMgmtPortId, lt2sTrapDetails, lt2sMgmtPortName }
+ STATUS current
+ DESCRIPTION "A link goes up in one of the management ports."
+ ::= { lt2sNotifications 14 }
+
+lt2sMgmtLinkDown NOTIFICATION-TYPE
+ OBJECTS { lt2sMgmtPortId, lt2sTrapDetails, lt2sMgmtPortName }
+ STATUS current
+ DESCRIPTION "A link goes down in one of the management ports."
+ ::= { lt2sNotifications 15 }
+
+lt2sMgmtTxLow NOTIFICATION-TYPE
+ OBJECTS { lt2sMgmtPortId, lt2sTrapDetails, lt2sMgmtPortName }
+ STATUS current
+ DESCRIPTION "Transceiver TX power is low in the management port."
+ ::= { lt2sNotifications 16 }
+
+lt2sMgmtTxHigh NOTIFICATION-TYPE
+ OBJECTS { lt2sMgmtPortId, lt2sTrapDetails, lt2sMgmtPortName }
+ STATUS current
+ DESCRIPTION "Transceiver TX power is high in the management port."
+ ::= { lt2sNotifications 17 }
+
+lt2sMgmtTxNormal NOTIFICATION-TYPE
+ OBJECTS { lt2sMgmtPortId, lt2sTrapDetails, lt2sMgmtPortName }
+ STATUS current
+ DESCRIPTION "Transceiver TX power is normal in the management port."
+ ::= { lt2sNotifications 18 }
+
+lt2sMgmtRxLow NOTIFICATION-TYPE
+ OBJECTS { lt2sMgmtPortId, lt2sTrapDetails, lt2sMgmtPortName }
+ STATUS current
+ DESCRIPTION "Transceiver RX power is low in the management port."
+ ::= { lt2sNotifications 19 }
+
+lt2sMgmtRxHigh NOTIFICATION-TYPE
+ OBJECTS { lt2sMgmtPortId, lt2sTrapDetails, lt2sMgmtPortName }
+ STATUS current
+ DESCRIPTION "Transceiver RX power is high in the management port."
+ ::= { lt2sNotifications 20 }
+
+lt2sMgmtRxNormal NOTIFICATION-TYPE
+ OBJECTS { lt2sMgmtPortId, lt2sTrapDetails, lt2sMgmtPortName }
+ STATUS current
+ DESCRIPTION "Transceiver RX power is normal in the management port."
+ ::= { lt2sNotifications 21 }
+
+lt2sPortEnabled NOTIFICATION-TYPE
+ OBJECTS { lt2sPortId, lt2sTrapDetails, lt2sPortName }
+ STATUS current
+ DESCRIPTION "Port is administrative enabled."
+ ::= { lt2sNotifications 22 }
+
+lt2sPortDisabled NOTIFICATION-TYPE
+ OBJECTS { lt2sPortId, lt2sTrapDetails, lt2sPortName }
+ STATUS current
+ DESCRIPTION "Port is administrative disabled."
+ ::= { lt2sNotifications 23 }
+
+lt2sPortReseted NOTIFICATION-TYPE
+ OBJECTS { lt2sPortId, lt2sTrapDetails, lt2sPortName }
+ STATUS current
+ DESCRIPTION "A reset in one of the ports."
+ ::= { lt2sNotifications 24 }
+
+lt2sPortThermalShutdown NOTIFICATION-TYPE
+ OBJECTS { lt2sPortId, lt2sTrapDetails, lt2sPortName }
+ STATUS current
+ DESCRIPTION "A thermal shut down in one of the ports."
+ ::= { lt2sNotifications 25 }
+
+lt2sPortThermalWakeup NOTIFICATION-TYPE
+ OBJECTS { lt2sPortId, lt2sTrapDetails, lt2sPortName }
+ STATUS current
+ DESCRIPTION "A thermal wakeup in one of the ports."
+ ::= { lt2sNotifications 26 }
+
+lt2sLinePluggedIn NOTIFICATION-TYPE
+ OBJECTS { lt2sPortId, lt2sTrapDetails, lt2sPortName }
+ STATUS current
+ DESCRIPTION "A SFP transceiver is plugged in, on one of the ports."
+ ::= { lt2sNotifications 27 }
+
+lt2sClientPluggedIn NOTIFICATION-TYPE
+ OBJECTS { lt2sPortId, lt2sTrapDetails, lt2sPortName }
+ STATUS current
+ DESCRIPTION "A SFP transceiver is plugged in, on one of the ports."
+ ::= { lt2sNotifications 28 }
+
+lt2sLinePluggedOut NOTIFICATION-TYPE
+ OBJECTS { lt2sPortId, lt2sTrapDetails, lt2sPortName }
+ STATUS current
+ DESCRIPTION "A SFP transceiver is plugged out, on one of the ports."
+ ::= { lt2sNotifications 29 }
+
+lt2sClientPluggedOut NOTIFICATION-TYPE
+ OBJECTS { lt2sPortId, lt2sTrapDetails, lt2sPortName }
+ STATUS current
+ DESCRIPTION "A SFP transceiver is plugged out, on one of the ports."
+ ::= { lt2sNotifications 30 }
+
+lt2sLineLinkUp NOTIFICATION-TYPE
+ OBJECTS { lt2sPortId, lt2sTrapDetails, lt2sPortName }
+ STATUS current
+ DESCRIPTION "A SFP transceiver's link goes up in one of the ports."
+ ::= { lt2sNotifications 31 }
+
+lt2sClientLinkUp NOTIFICATION-TYPE
+ OBJECTS { lt2sPortId, lt2sTrapDetails, lt2sPortName }
+ STATUS current
+ DESCRIPTION "A SFP transceiver's link goes up in one of the ports."
+ ::= { lt2sNotifications 32 }
+
+lt2sLineLinkDown NOTIFICATION-TYPE
+ OBJECTS { lt2sPortId, lt2sTrapDetails, lt2sPortName }
+ STATUS current
+ DESCRIPTION "A SFP transceiver's link goes down in one of the ports."
+ ::= { lt2sNotifications 33 }
+
+lt2sClientLinkDown NOTIFICATION-TYPE
+ OBJECTS { lt2sPortId, lt2sTrapDetails, lt2sPortName }
+ STATUS current
+ DESCRIPTION "A SFP transceiver's link goes down in one of the ports."
+ ::= { lt2sNotifications 34 }
+
+lt2sLineLoopOn NOTIFICATION-TYPE
+ OBJECTS { lt2sPortId, lt2sTrapDetails, lt2sPortName }
+ STATUS current
+ DESCRIPTION "A Line loop is activated in one of the ports."
+ ::= { lt2sNotifications 35 }
+
+lt2sLineLoopOff NOTIFICATION-TYPE
+ OBJECTS { lt2sPortId, lt2sTrapDetails, lt2sPortName }
+ STATUS current
+ DESCRIPTION "A Line loop is turned off in one of the ports."
+ ::= { lt2sNotifications 36 }
+
+lt2sClientLoopOn NOTIFICATION-TYPE
+ OBJECTS { lt2sPortId, lt2sTrapDetails, lt2sPortName }
+ STATUS current
+ DESCRIPTION "A Client loop is activated in one of the ports."
+ ::= { lt2sNotifications 37 }
+
+lt2sClientLoopOff NOTIFICATION-TYPE
+ OBJECTS { lt2sPortId, lt2sTrapDetails, lt2sPortName }
+ STATUS current
+ DESCRIPTION "A Client loop is turned off in one of the ports."
+ ::= { lt2sNotifications 38 }
+
+lt2sPortTxLow NOTIFICATION-TYPE
+ OBJECTS { lt2sPortId, lt2sTrapDetails, lt2sPortName }
+ STATUS current
+ DESCRIPTION "A SFP transceiver TX power is low in one of the ports."
+ ::= { lt2sNotifications 39 }
+
+lt2sPortTxHigh NOTIFICATION-TYPE
+ OBJECTS { lt2sPortId, lt2sTrapDetails, lt2sPortName }
+ STATUS current
+ DESCRIPTION "A SFP transceiver TX power is high in one of the ports."
+ ::= { lt2sNotifications 40 }
+
+lt2sPortTxNormal NOTIFICATION-TYPE
+ OBJECTS { lt2sPortId, lt2sTrapDetails, lt2sPortName }
+ STATUS current
+ DESCRIPTION "A SFP transceiver TX power is normal in one of the ports."
+ ::= { lt2sNotifications 41 }
+
+lt2sPortRxLow NOTIFICATION-TYPE
+ OBJECTS { lt2sPortId, lt2sTrapDetails, lt2sPortName }
+ STATUS current
+ DESCRIPTION "A SFP transceiver RX power is low in one of the ports."
+ ::= { lt2sNotifications 42 }
+
+lt2sPortRxHigh NOTIFICATION-TYPE
+ OBJECTS { lt2sPortId, lt2sTrapDetails, lt2sPortName }
+ STATUS current
+ DESCRIPTION "A SFP transceiver RX power is high in one of the ports."
+ ::= { lt2sNotifications 43 }
+
+lt2sPortRxNormal NOTIFICATION-TYPE
+ OBJECTS { lt2sPortId, lt2sTrapDetails, lt2sPortName }
+ STATUS current
+ DESCRIPTION "A SFP transceiver RX power is normal in one of the ports."
+ ::= { lt2sNotifications 44 }
+
+
+lt2sCompliance MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION "Describes the requirements for conformance to the
+ Lambdatrail2 MIB part."
+ MODULE
+ MANDATORY-GROUPS { lt2sAgentGroup, lt2sSystemGroup, lt2sPortsGroup,
+ lt2sInfoGroup, lt2sNotificationGroup }
+ ::= { lt2sCompliances 1 }
+
+lt2sAgentGroup OBJECT-GROUP
+ OBJECTS { lt2sDescription, lt2sDeviceType, lt2sHwRevision, lt2sManufacturingDate,
+ lt2sSerialNumber, lt2sSystemName, lt2sSystemLocation, lt2sSystemContact,
+ lt2sSystemUptime, lt2sFirmwareVersion, lt2suCVersion, lt2sSaveRunningCfg,
+ lt2sResetAgent, lt2sSnmpGetCommunity, lt2sSnmpSetCommunity, lt2sIp4DHCP,
+ lt2sIp4Address, lt2sIp4Mask, lt2sIp4Gateway, lt2sIp4PrimaryDns,
+ lt2sIp4SecondaryDns, lt2sSnmpServer, lt2sHttpServer, lt2sTelnetServer,
+ lt2sFtpServer, lt2sMgmtPortId, lt2sMgmtPortName,
+ lt2sMgmtPortEnable, lt2sMgmtPortLink, lt2sMgmtPortSpeed, lt2sMgmtPortTxBytes,
+ lt2sMgmtPortRxBytes, lt2sMgmtSfpPlugged, lt2sMgmtSfpVendor, lt2sMgmtSfpType,
+ lt2sMgmtSfpSerial, lt2sMgmtSfpWavelength, lt2sMgmtSfpTxPower, lt2sMgmtSfpRxPower,
+ lt2sMgmtSfpLaserTemp, lt2sMgmtSfpLaserBias, lt2sMgmtSfpTxLow, lt2sMgmtSfpTxHigh,
+ lt2sMgmtSfpRxLow, lt2sMgmtSfpRxHigh }
+ STATUS current
+ DESCRIPTION "Grouping all LT2-S Agent parameters."
+ ::= { lt2sGroups 1 }
+
+lt2sSystemGroup OBJECT-GROUP
+ OBJECTS { lt2sTemperature, lt2sPowerType, lt2sPowerStatus, lt2sPowerFanStatus,
+ lt2sPowerFanRPM, lt2sPowerFanMode, lt2sPowerFanOnTemp, lt2sPowerFanOffTemp }
+ STATUS current
+ DESCRIPTION "Grouping all LT2-S system parameters."
+ ::= { lt2sGroups 2 }
+
+lt2sPortsGroup OBJECT-GROUP
+ OBJECTS { lt2sPortId, lt2sPortEnable, lt2sPortApsd, lt2sPortSpeed, lt2sPortReset,
+ lt2sPortLoop, lt2sPortName, lt2sLinePlugged, lt2sLineType, lt2sLineLink,
+ lt2sLineApsd, lt2sLineWavelength, lt2sLineTxPower, lt2sLineRxPower,
+ lt2sLineLaserTemp, lt2sLineLaserBias, lt2sClientPlugged, lt2sClientType,
+ lt2sClientLink, lt2sClientApsd, lt2sClientWavelength, lt2sClientTxPower,
+ lt2sClientRxPower, lt2sClientLaserTemp, lt2sClientLaserBias, lt2sLineTxLow,
+ lt2sLineTxHigh, lt2sLineRxLow, lt2sLineRxHigh, lt2sClientTxLow, lt2sClientTxHigh,
+ lt2sClientRxLow, lt2sClientRxHigh }
+ STATUS current
+ DESCRIPTION "Grouping all LT2-S port parameters."
+ ::= { lt2sGroups 3 }
+
+lt2sInfoGroup OBJECT-GROUP
+ OBJECTS { lt2sTrapDetails }
+ STATUS current
+ DESCRIPTION "Grouping all LT2-S info parameters."
+ ::= { lt2sGroups 4 }
+
+lt2sNotificationGroup NOTIFICATION-GROUP
+ NOTIFICATIONS { lt2sMgmtStartup, lt2sMgmtAuthenticationFailure, lt2sTemperatureHigh,
+ lt2sTemperatureNormal, lt2sPowerSupplyPluggedIn, lt2sPowerSupplyPluggedOut,
+ lt2sPowerNormal, lt2sPowerFailure, lt2sFanOn, lt2sFanOff, lt2sFanFailure,
+ lt2sPortEnabled, lt2sPortDisabled, lt2sPortReseted, lt2sPortThermalShutdown,
+ lt2sPortThermalWakeup, lt2sMgmtSfpPluggedIn, lt2sLinePluggedIn, lt2sClientPluggedIn,
+ lt2sMgmtSfpPluggedOut, lt2sLinePluggedOut, lt2sClientPluggedOut, lt2sMgmtLinkUp,
+ lt2sLineLinkUp, lt2sClientLinkUp, lt2sMgmtLinkDown, lt2sLineLinkDown,
+ lt2sClientLinkDown, lt2sLineLoopOn, lt2sLineLoopOff, lt2sClientLoopOn,
+ lt2sClientLoopOff, lt2sMgmtTxLow, lt2sPortTxLow, lt2sMgmtTxHigh, lt2sPortTxHigh,
+ lt2sMgmtTxNormal, lt2sPortTxNormal, lt2sMgmtRxLow, lt2sPortRxLow, lt2sMgmtRxHigh,
+ lt2sPortRxHigh, lt2sMgmtRxNormal, lt2sPortRxNormal }
+ STATUS current
+ DESCRIPTION "All the Traps the Lambdatrail2-S supports."
+ ::= { lt2sGroups 5 }
+
+END