summaryrefslogtreecommitdiff
path: root/MIBS/dasan/SLE-MPLS-TP-NODE-MIB
diff options
context:
space:
mode:
Diffstat (limited to 'MIBS/dasan/SLE-MPLS-TP-NODE-MIB')
-rw-r--r--MIBS/dasan/SLE-MPLS-TP-NODE-MIB286
1 files changed, 286 insertions, 0 deletions
diff --git a/MIBS/dasan/SLE-MPLS-TP-NODE-MIB b/MIBS/dasan/SLE-MPLS-TP-NODE-MIB
new file mode 100644
index 0000000..88eab81
--- /dev/null
+++ b/MIBS/dasan/SLE-MPLS-TP-NODE-MIB
@@ -0,0 +1,286 @@
+--
+-- sle-mpls-tp-node-mib.mib
+-- MIB generated by MG-SOFT Visual MIB Builder Version 6.0 Build 88
+-- Tuesday, January 12, 2016 at 11:22:02
+--
+
+ SLE-MPLS-TP-NODE-MIB DEFINITIONS ::= BEGIN
+
+ IMPORTS
+ sleMgmt
+ FROM DASAN-SMI
+ MplsCcId, MplsIccId
+ FROM MPLS-TC-EXT-STD-MIB
+ mplsTunnelIndex, mplsTunnelInstance, mplsTunnelIngressLSRId, mplsTunnelEgressLSRId
+ FROM MPLS-TE-STD-MIB
+ SleControlStatusType, SleControlRequestResultType
+ FROM SLE-TC-MIB
+ zeroDotZero, TimeTicks, IpAddress, Unsigned32, Gauge32,
+ OBJECT-TYPE, MODULE-IDENTITY, OBJECT-IDENTITY
+ FROM SNMPv2-SMI;
+
+
+ sleMplsTpNode MODULE-IDENTITY
+ LAST-UPDATED "201510070000Z" -- October 07, 2015 at 00:00 GMT
+ ORGANIZATION
+ "Multiprotocol Label Switching (MPLS) Working Group"
+ CONTACT-INFO
+ "Gyerok Kwon
+ Dasan Networks
+ Email: grkwon@dasannetworks.com
+
+ Kantharaj B M
+ Dasan Networks
+ Email: kanth@dasannetworks.com
+
+ DongChel Shin (Chris)
+ Dasan Networks
+ Email: dchshin@dasannetworks.com
+
+ Comments about this document should be emailed
+ directly to the Dasan support email ID at
+ support@dasannetworks.com."
+ DESCRIPTION
+ "Copyright (c) 2012 IETF Trust and the persons identified
+ as the document authors. All rights reserved.
+
+ This MIB module contains generic object definitions for
+ MPLS Traffic Engineering in transport networks."
+ REVISION "201207150000Z" -- July 15, 2012 at 00:00 GMT
+ DESCRIPTION
+ "MPLS_TP node configuration table"
+ ::= { sleMpls 13 }
+
+
+
+
+--
+-- Node definitions
+--
+
+ sleMpls OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "SLE MPLS."
+ ::= { sleMgmt 16 }
+
+
+ sleMplsTpNodeCfg OBJECT IDENTIFIER ::= { sleMplsTpNode 1 }
+
+
+ sleMplsTpNodeCfgInfo OBJECT IDENTIFIER ::= { sleMplsTpNodeCfg 1 }
+
+
+ sleMplsTpNodeCfgInfoGlobalId OBJECT-TYPE
+ SYNTAX Unsigned32 (1..4294967295)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object indicates the Global Operator Identifier.
+ this object value should be zero when
+ sleMplsTpNodeConfigInfoCcId and sleMplsTpNodeConfigInfoICcId
+ is configured with non-null value."
+ REFERENCE
+ "MPLS-TP Identifiers [RFC6370]."
+ ::= { sleMplsTpNodeCfgInfo 1 }
+
+
+ sleMplsTpNodeCfgInfoItutCc OBJECT-TYPE
+ SYNTAX MplsCcId
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object allows the operator or service provider to
+ configure a unique MPLS-TP ITU-T Carrier Code (ICC)
+ either for Ingress ID or Egress ID.
+
+ This object value should be zero when
+ sleMplsTpNodeConfigInfoGlobalId are assigned with non-zero value."
+ REFERENCE
+ "MPLS-TP Identifiers [RFC6370]."
+ ::= { sleMplsTpNodeCfgInfo 2 }
+
+
+ sleMplsTpNodeCfgInfoItutIcc OBJECT-TYPE
+ SYNTAX MplsIccId
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object allows the operator or service provider to
+ configure a unique MPLS-TP ITU-T Carrier Code (ICC)
+ either for Ingress ID or Egress ID.
+
+ This object value should be zero when
+ sleMplsTpNodeConfigInfoGlobalId are assigned with non-zero value."
+ REFERENCE
+ "MPLS-TP Identifiers [RFC6370]."
+ ::= { sleMplsTpNodeCfgInfo 3 }
+
+
+ sleMplsTpNodeCfgInfoNodeId OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object indicates the Node_ID within the operator."
+ REFERENCE
+ "MPLS-TP Identifiers [RFC6370]."
+ ::= { sleMplsTpNodeCfgInfo 4 }
+
+
+ sleMplsTpNodeCfgInfoNodeType OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ ietf(1),
+ itut(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object value should be zero when
+ sleMplsTpNodeConfigInfoGlobalId are assigned with non-zero value ."
+ ::= { sleMplsTpNodeCfgInfo 5 }
+
+
+ sleMplsTpNodeCfgControl OBJECT IDENTIFIER ::= { sleMplsTpNodeCfg 2 }
+
+
+ sleMplsTpNodeCfgControlRequest OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ setMplsTpNode(1),
+ unsetMplsTpNode(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object holds the possible read-write columns that can be
+ modified in the TunnelExtNodeConfigTable table. For each read-write
+ column of TunnelExtNodeConfigTable table, a Set Operation control
+ value is added in this object."
+ ::= { sleMplsTpNodeCfgControl 1 }
+
+
+ sleMplsTpNodeCfgControlStatus OBJECT-TYPE
+ SYNTAX SleControlStatusType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object displays the status of the configuration done."
+ ::= { sleMplsTpNodeCfgControl 2 }
+
+
+ sleMplsTpNodeCfgControlTimer OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object is based on the SLE style where a timer is configured
+ for every control table."
+ ::= { sleMplsTpNodeCfgControl 3 }
+
+
+ sleMplsTpNodeCfgControlTimestamp OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object specifies the time at which the configuration is done."
+ ::= { sleMplsTpNodeCfgControl 4 }
+
+
+ sleMplsTpNodeCfgControlReqResult OBJECT-TYPE
+ SYNTAX SleControlRequestResultType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The standard result of the SET operation is stored here."
+ ::= { sleMplsTpNodeCfgControl 5 }
+
+
+ sleMplsTpNodeCfgControlGlobalId OBJECT-TYPE
+ SYNTAX Unsigned32 (1..4294967295)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object indicates the Global Operator Identifier.
+ This object value should be zero when
+ sleMplsTpNodeConfigControlIccId and sleMplsTpNodeConfigControlccId
+ is configured with non-null value."
+ REFERENCE
+ "MPLS-TP Identifiers [RFC6370]."
+ ::= { sleMplsTpNodeCfgControl 6 }
+
+
+ sleMplsTpNodeCfgControlItutCc OBJECT-TYPE
+ SYNTAX MplsCcId
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object allows the operator or service provider to
+ configure a unique MPLS-TP ITU-T Carrier Code (ICC)
+ either for Ingress ID or Egress ID.
+
+ This object value should be zero when
+ sleMplsTpNodeConfigControlGlobalId are assigned with
+ non-zero value."
+ REFERENCE
+ "MPLS-TP Identifiers [RFC6370]."
+ ::= { sleMplsTpNodeCfgControl 7 }
+
+
+ sleMplsTpNodeCfgControlItutIcc OBJECT-TYPE
+ SYNTAX MplsIccId
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object allows the operator or service provider to configure a
+ unique MPLS-TP ITU-T Carrier Code (ICC) either for Ingress ID
+ or Egress ID.
+
+ This object value should be zero when
+ sleMplsTpNodeConfigControlGlobalId are assigned with non-zero
+ value."
+ REFERENCE
+ "MPLS-TP Identifiers [RFC6370]."
+ ::= { sleMplsTpNodeCfgControl 8 }
+
+
+ sleMplsTpNodeCfgControlNodeId OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object indicates the Node_ID within the operator."
+ REFERENCE
+ "MPLS-TP Identifiers [RFC6370]."
+ ::= { sleMplsTpNodeCfgControl 9 }
+
+
+ sleMplsTpNodeCfgControlNodeType OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ ietf(1),
+ itut(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object allows the operator or service provider to
+ configure a unique MPLS-TP ITU-T Carrier Code (ICC)
+ either for Ingress ID or Egress ID.
+
+ This object value should be zero when
+ msleMplsTpNodeConfigControlGlobalId are assigned with non-zero
+ value."
+ REFERENCE
+ "MPLS-TP Identifiers [RFC6370]."
+ ::= { sleMplsTpNodeCfgControl 10 }
+
+
+
+ END
+
+--
+-- sle-mpls-tp-node-mib.mib
+--