diff options
Diffstat (limited to 'MIBS/dasan/SLE-MPLS-TP-BFD-MIB')
| -rw-r--r-- | MIBS/dasan/SLE-MPLS-TP-BFD-MIB | 439 |
1 files changed, 439 insertions, 0 deletions
diff --git a/MIBS/dasan/SLE-MPLS-TP-BFD-MIB b/MIBS/dasan/SLE-MPLS-TP-BFD-MIB new file mode 100644 index 0000000..95cc487 --- /dev/null +++ b/MIBS/dasan/SLE-MPLS-TP-BFD-MIB @@ -0,0 +1,439 @@ +--
+-- sle-mpls-tp-bfd-mib.mib
+-- MIB generated by MG-SOFT Visual MIB Builder Version 6.0 Build 88
+-- Tuesday, January 12, 2016 at 17:14:36
+--
+
+ SLE-MPLS-TP-BFD-MIB DEFINITIONS ::= BEGIN
+
+ IMPORTS
+ sleMgmt
+ FROM DASAN-SMI
+ IANAbfdDiagTC
+ FROM IANA-BFD-TC-STD-MIB
+ SleControlStatusType, SleControlRequestResultType
+ FROM SLE-TC-MIB
+ mib-2, TimeTicks, Unsigned32, Gauge32, OBJECT-TYPE,
+ MODULE-IDENTITY, OBJECT-IDENTITY
+ FROM SNMPv2-SMI;
+
+
+ sleMplsTpBfd MODULE-IDENTITY
+ LAST-UPDATED "201510070000Z" -- October 07, 2015 at 00:00 GMT
+ ORGANIZATION
+ "Dasan Networks"
+ CONTACT-INFO
+ "Gyerok Kwon
+ Dasan Networks
+ Email: grkwon@dasannetworks.com
+
+ Kantharaj B M
+ Dasan Networks
+ Email: kanth@dasannetworks.com
+
+ DongChel Shin (Chris)
+ Dasan Networks
+ Email: dchshin@dasannetworks.com
+
+ Comments about this document should be emailed
+ directly to the Dasan support email ID at
+ support@dasannetworks.com."
+ DESCRIPTION
+ "Bidirectional Forwarding Management Information Base."
+ REVISION "200406030000Z" -- June 03, 2004 at 00:00 GMT
+ DESCRIPTION
+ "Initial version issued as part of RFC 3812."
+ ::= { sleMpls 19 }
+
+
+
+
+--
+-- Node definitions
+--
+
+ sleMpls OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "SLE MPLS."
+ ::= { sleMgmt 16 }
+
+
+ sleMplsTpBfdCfg OBJECT IDENTIFIER ::= { sleMplsTpBfd 1 }
+
+
+ sleMplsTpBfdCfgInfoTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SleBfdCfgInfoEntry
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The BFD Cfg Table describes the configuration details."
+ ::= { sleMplsTpBfdCfg 1 }
+
+
+ sleMplsTpBfdCfgInfoEntry OBJECT-TYPE
+ SYNTAX SleBfdCfgInfoEntry
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The BFD Session Entry describes BFD session."
+ INDEX { sleMplsTpBfdCfgInfoMegIndex, sleMplsTpBfdCfgInfoMeIndex }
+ ::= { sleMplsTpBfdCfgInfoTable 1 }
+
+
+ SleBfdCfgInfoEntry ::=
+ SEQUENCE {
+ sleMplsTpBfdCfgInfoMegIndex
+ Unsigned32,
+ sleMplsTpBfdCfgInfoMeIndex
+ Unsigned32,
+ sleMplsTpBfdCfgInfoMegName
+ OCTET STRING,
+ sleMplsTpBfdCfgInfoMeName
+ OCTET STRING,
+ sleMplsTpBfdCfgInfoTxInterval
+ OCTET STRING,
+ sleMplsTpBfdCfgInfoRXInterval
+ OCTET STRING
+ }
+
+ sleMplsTpBfdCfgInfoMegIndex OBJECT-TYPE
+ SYNTAX Unsigned32 (1..65535)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "MEG Index."
+ ::= { sleMplsTpBfdCfgInfoEntry 1 }
+
+
+ sleMplsTpBfdCfgInfoMeIndex OBJECT-TYPE
+ SYNTAX Unsigned32 (1..65535)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Maintenance Entity Index."
+ ::= { sleMplsTpBfdCfgInfoEntry 2 }
+
+
+ sleMplsTpBfdCfgInfoMegName OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "MEG Index."
+ ::= { sleMplsTpBfdCfgInfoEntry 3 }
+
+
+ sleMplsTpBfdCfgInfoMeName OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Maintenance Entity Index."
+ ::= { sleMplsTpBfdCfgInfoEntry 4 }
+
+
+ sleMplsTpBfdCfgInfoTxInterval OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "TX Packet Interval of BFD to neighbor."
+ ::= { sleMplsTpBfdCfgInfoEntry 5 }
+
+
+ sleMplsTpBfdCfgInfoRXInterval OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "RX Packet Interval of BFD from neighbor."
+ ::= { sleMplsTpBfdCfgInfoEntry 6 }
+
+
+ sleMplsTpBfdCfgControl OBJECT IDENTIFIER ::= { sleMplsTpBfdCfg 2 }
+
+
+ sleMplsTpBfdCfgControlRequest OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ createBfdcfgEntry(1),
+ deleteBfdCfgEntry(2),
+ setIntervals(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object holds the possible read-write columns that can be
+ modified in the BFD Config table. For each read-write column of
+ BFD config table, a Set Operation control value is added in this
+ object."
+ ::= { sleMplsTpBfdCfgControl 1 }
+
+
+ sleMplsTpBfdCfgControlStatus OBJECT-TYPE
+ SYNTAX SleControlStatusType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object displays the status of the configuration done."
+ ::= { sleMplsTpBfdCfgControl 2 }
+
+
+ sleMplsTpBfdCfgControlTimer OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object is based on the SLE style where a timer is
+ configured for every control table."
+ ::= { sleMplsTpBfdCfgControl 3 }
+
+
+ sleMplsTpBfdCfgControlTimestamp OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object specifies the time at which the configuration is done."
+ ::= { sleMplsTpBfdCfgControl 4 }
+
+
+ sleMplsTpBfdCfgControlReqResult OBJECT-TYPE
+ SYNTAX SleControlRequestResultType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The standard result of the SET operation is stored here."
+ ::= { sleMplsTpBfdCfgControl 5 }
+
+
+ sleMplsTpBfdCfgControlMegName OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "MEG Name."
+ ::= { sleMplsTpBfdCfgControl 6 }
+
+
+ sleMplsTpBfdCfgControlMeName OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Maintenance Entity Name."
+ ::= { sleMplsTpBfdCfgControl 7 }
+
+
+ sleMplsTpBfdCfgControlTxInterval OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "TX Packet Interval of BFD to neighbor."
+ ::= { sleMplsTpBfdCfgControl 8 }
+
+
+ sleMplsTpBfdCfgControlRXInterval OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "RX Packet Interval of BFD from neighbor."
+ ::= { sleMplsTpBfdCfgControl 9 }
+
+
+ sleMplsTpBfdSession OBJECT IDENTIFIER ::= { sleMplsTpBfd 2 }
+
+
+ sleMplsTpBfdSessionInfoTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SleBfdSessionInfoEntry
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The BFD Session Table describes the BFD sessions."
+ REFERENCE
+ "Katz, D. and D. Ward, Bidirectional Forwarding
+ Detection (BFD), RFC 5880, June 2012."
+ ::= { sleMplsTpBfdSession 1 }
+
+
+ sleMplsTpBfdSessionInfoEntry OBJECT-TYPE
+ SYNTAX SleBfdSessionInfoEntry
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The BFD Session Entry describes BFD session."
+ INDEX { sleMplsTpBfdSessionInfoSessIndex }
+ ::= { sleMplsTpBfdSessionInfoTable 1 }
+
+
+ SleBfdSessionInfoEntry ::=
+ SEQUENCE {
+ sleMplsTpBfdSessionInfoSessIndex
+ Unsigned32,
+ sleMplsTpBfdSessionInfoMegName
+ OCTET STRING,
+ sleMplsTpBfdSessionInfoMeName
+ OCTET STRING,
+ sleMplsTpBfdSessionInfoVersionNumber
+ Unsigned32,
+ sleMplsTpBfdSessionInfoDiscriminator
+ Unsigned32,
+ sleMplsTpBfdSessionInfoRemoteDiscriminator
+ Unsigned32,
+ sleMplsTpBfdSessionInfoState
+ INTEGER,
+ sleMplsTpBfdSessionInfoDiag
+ IANAbfdDiagTC,
+ sleMplsTpBfdSessionInfoDesiredMinTxInterval
+ OCTET STRING,
+ sleMplsTpBfdSessionInfoReqMinRxInterval
+ OCTET STRING,
+ sleMplsTpBfdSessionInfoDetectMult
+ Unsigned32
+ }
+
+ sleMplsTpBfdSessionInfoSessIndex OBJECT-TYPE
+ SYNTAX Unsigned32 (1..65535)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This object contains an index used to represent a
+ unique BFD session on this device."
+ ::= { sleMplsTpBfdSessionInfoEntry 1 }
+
+
+ sleMplsTpBfdSessionInfoMegName OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "MEG Name of the BFD Session."
+ ::= { sleMplsTpBfdSessionInfoEntry 2 }
+
+
+ sleMplsTpBfdSessionInfoMeName OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "MEG Name of the BFD Session."
+ ::= { sleMplsTpBfdSessionInfoEntry 3 }
+
+
+ sleMplsTpBfdSessionInfoVersionNumber OBJECT-TYPE
+ SYNTAX Unsigned32 (0..7)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The version number of the BFD protocol that this session
+ is running in. Write access is available for this object
+ to provide ability to set desired version for this
+ BFD session."
+ REFERENCE
+ "Katz, D. and D. Ward, Bidirectional Forwarding
+ Detection (BFD), RFC 5880, June 2012."
+ DEFVAL { 1 }
+ ::= { sleMplsTpBfdSessionInfoEntry 4 }
+
+
+ sleMplsTpBfdSessionInfoDiscriminator OBJECT-TYPE
+ SYNTAX Unsigned32 (1..4294967295)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object specifies the local discriminator for this BFD
+ session, used to uniquely identify it."
+ ::= { sleMplsTpBfdSessionInfoEntry 5 }
+
+
+ sleMplsTpBfdSessionInfoRemoteDiscriminator OBJECT-TYPE
+ SYNTAX Unsigned32 (0 | 1..4294967295)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object specifies the session discriminator chosen
+ by the remote system for this BFD session. The value may
+ be zero(0) if the remote discriminator is not yet known
+ or if the session is in the down or adminDown(1) state."
+ REFERENCE
+ "Section 6.8.6, from Katz, D. and D. Ward, Bidirectional
+ Forwarding Detection (BFD), RFC 5880, June 2012."
+ ::= { sleMplsTpBfdSessionInfoEntry 6 }
+
+
+ sleMplsTpBfdSessionInfoState OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ adminDown(0),
+ stateDown(1),
+ stateInit(2),
+ stateUp(3),
+ unknown(4)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "BFD session state."
+ ::= { sleMplsTpBfdSessionInfoEntry 7 }
+
+
+ sleMplsTpBfdSessionInfoDiag OBJECT-TYPE
+ SYNTAX IANAbfdDiagTC
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A diagnostic code specifying the local system's reason
+ for the last transition of the session from up(4)
+ to some other state."
+ ::= { sleMplsTpBfdSessionInfoEntry 8 }
+
+
+ sleMplsTpBfdSessionInfoDesiredMinTxInterval OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object specifies the minimum interval, in
+ microseconds, that the local system would like to use
+ when transmitting BFD Control packets. The value of
+ zero(0) is reserved, and should not be used."
+ REFERENCE
+ "Section 4.1 from Katz, D. and D. Ward, Bidirectional
+ Forwarding Detection (BFD), RFC 5880, June 2012."
+ ::= { sleMplsTpBfdSessionInfoEntry 9 }
+
+
+ sleMplsTpBfdSessionInfoReqMinRxInterval OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object specifies the minimum interval, in
+ microseconds, between received BFD Control packets the
+ local system is capable of supporting. The value of
+ zero(0) can be specified when the transmitting system
+ does not want the remote system to send any periodic BFD
+ control packets."
+ REFERENCE
+ "Section 4.1 from Katz, D. and D. Ward, Bidirectional
+ Forwarding Detection (BFD), RFC 5880, June 2012."
+ ::= { sleMplsTpBfdSessionInfoEntry 10 }
+
+
+ sleMplsTpBfdSessionInfoDetectMult OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION " "
+ ::= { sleMplsTpBfdSessionInfoEntry 11 }
+
+
+
+ END
+
+--
+-- sle-mpls-tp-bfd-mib.mib
+--
|