diff options
Diffstat (limited to 'MIBS/ctm/CTMMIBCUSTOM')
| -rw-r--r-- | MIBS/ctm/CTMMIBCUSTOM | 562 |
1 files changed, 562 insertions, 0 deletions
diff --git a/MIBS/ctm/CTMMIBCUSTOM b/MIBS/ctm/CTMMIBCUSTOM new file mode 100644 index 0000000..d58e22d --- /dev/null +++ b/MIBS/ctm/CTMMIBCUSTOM @@ -0,0 +1,562 @@ +-- Last Mile Gear CTM Master MIB +-- This mib was custom edited to add Slave information +-- Mar 27, 2018 - Paul Heinrichs <pdheinrichs@gmail.com> + + +CTMMIBCUSTOM DEFINITIONS ::= BEGIN + IMPORTS + enterprises + FROM RFC1155-SMI + OBJECT-TYPE + FROM RFC-1212 + TRAP-TYPE + FROM RFC-1215; + + + lastmilegear OBJECT IDENTIFIER ::= { enterprises 25868 } + + mibObjects OBJECT IDENTIFIER ::= { lastmilegear 1 } + + version OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION "Version of Web GUI - Version of Web GUI Interface + currently running on CTM" + ::= { mibObjects 1 } + + site OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION "Site Name - Site name as stored on CTM" + ::= { mibObjects 2 } + + lastIP OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION "Last IP Address Login - Last IP address captured + at Login Attempt" + ::= { mibObjects 3 } + + lastTime OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION "Last Time Login - Last time of Login attempt" + ::= { mibObjects 4 } + + nSats OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION "Number Satellites in View - Number of Satellites + in view of GPS Receiver Antenna being used for + timing calculations" + ::= { mibObjects 5 } + + pwrP OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION "Master Primary Power - Master ?1? = Power OK, + ?0? = Power Off or Low" + ::= { mibObjects 6 } + + pwrS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION "Master Secondary Power - Master ?1? = Power OK, + ?0? = Power Off or Low" + ::= { mibObjects 7 } + + cbTrip OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION "Master Circuit Breaker Trip Bit Code - Master + Breaker Tripped Code: 1=Port 1, 2=Port2, 4=Port + 3, 8=Port4, 16=Port5, 32=Port6, 64=Port7, 128=Port8 + Example: Code 5 means Port 3 and Port 1 Tripped" + ::= { mibObjects 8 } + + tempC OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION "Master Temperature" + ::= { mibObjects 9 } + + voltsM1 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION "Master Primary Power In Voltage - In Tenths of + a Volt" + ::= { mibObjects 10 } + + voltsM2 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION "Master Secondary Power In Voltage - In Tenths + of a Volt" + ::= { mibObjects 11 } + + portOnM OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION "Master Ports ON Enabled Status - Master ?1? =Sync + Enabled, ?0? = Sync Off listed in order ?Port1?, + ?Port2?, ?Port3?, ?Port4?, ?Port5?, ?Port6?, + ?Port7?, ?Port8?" + ::= { mibObjects 12 } + + portSyncM OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION "Master Ports Sync Enabled Status - Master ?1? + =Sync Enabled, ?0? = Sync Off listed in order + ?Port1?, ?Port2?, ?Port3?, ?Port4?, ?Port5?, + ?Port6?, ?Port7?, ?Port8?" + ::= { mibObjects 13 } + + portPwrM1 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION "Master Power Port 1 - (in tenths of a Watt) delivered + on Port 1" + ::= { mibObjects 14 } + + portPwrM2 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION "Master Power Port 2 - (in tenths of a Watt) delivered + on Port 2" + ::= { mibObjects 15 } + + portPwrM3 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION "Master Power Port 3 - (in tenths of a Watt) delivered + on Port 3" + ::= { mibObjects 16 } + + portPwrM4 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION "Master Power Port 4 - (in tenths of a Watt) delivered + on Port 4" + ::= { mibObjects 17 } + + portPwrM5 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION "Master Power Port 5 - (in tenths of a Watt) delivered + on Port 5" + ::= { mibObjects 18 } + + portPwrM6 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION "Master Power Port 6 - (in tenths of a Watt) delivered + on Port 6" + ::= { mibObjects 19 } + + portPwrM7 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION "Master Power Port 7 - (in tenths of a Watt) delivered + on Port 7" + ::= { mibObjects 20 } + + portPwrM8 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION "Master Power Port 8 - (in tenths of a Watt) delivered + on Port 8" + ::= { mibObjects 21 } + + pwrSP OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION "Slave Primary Power - Master ?1? = Power OK, + ?0? = Power Off or Low" + ::= { mibObjects 23 } + + pwrSS OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION "Slave Secondary Power - Master ?1? = Power OK, + ?0? = Power Off or Low" + ::= { mibObjects 24 } + + voltsS1 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION "Slave Primary Power In Voltage - In Tenths of + a Volt" + ::= { mibObjects 27 } + + voltsS2 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION "Slave Secondary Power In Voltage - In Tenths + of a Volt" + ::= { mibObjects 28 } + + portOnS OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION "Slave Ports ON Enabled Status - Slave ?1? =Sync + Enabled, ?0? = Sync Off listed in order ?Port1?, + ?Port2?, ?Port3?, ?Port4?, ?Port5?, ?Port6?, + ?Port7?, ?Port8?" + ::= { mibObjects 29 } + + portSyncS OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION "Slave Ports Sync Enabled Status - Slave ?1? + =Sync Enabled, ?0? = Sync Off listed in order + ?Port1?, ?Port2?, ?Port3?, ?Port4?, ?Port5?, + ?Port6?, ?Port7?, ?Port8?" + ::= { mibObjects 30 } + + portPwrS1 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION "Slave Power Port 1 - (in tenths of a Watt) delivered + on Port 1" + ::= { mibObjects 31 } + + portPwrS2 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION "Slave Power Port 2 - (in tenths of a Watt) delivered + on Port 2" + ::= { mibObjects 32 } + + portPwrS3 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION "Slave Power Port 3 - (in tenths of a Watt) delivered + on Port 3" + ::= { mibObjects 33 } + + portPwrS4 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION "Slave Power Port 4 - (in tenths of a Watt) delivered + on Port 4" + ::= { mibObjects 34 } + + portPwrS5 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION "Slave Power Port 5 - (in tenths of a Watt) delivered + on Port 5" + ::= { mibObjects 35 } + + portPwrS6 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION "Slave Power Port 6 - (in tenths of a Watt) delivered + on Port 6" + ::= { mibObjects 36 } + + portPwrS7 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION "Slave Power Port 7 - (in tenths of a Watt) delivered + on Port 7" + ::= { mibObjects 37 } + + portPwrS8 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION "Slave Power Port 8 - (in tenths of a Watt) delivered + on Port 8" + ::= { mibObjects 38 } + + modeReqM OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION "Master CTM2 Port Type Setting - Master ?00?=Type + A (Canopy) ?10?=Type B (OFDM), ?01? = Type C + (POE 802.3at), ?11? (POE 802.3at 4 Pair), ?100?=(POE + 24V mode, CTM2 C Only) listed in order ?Port1?, + ?Port2?, ?Port3?, ?Port4?, ?Port5?, ?Port6?, + ?Port7?, ?Port8?" + ::= { mibObjects 39 } + + trpCntGM1 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION "Master Auto Restart Count Port 1 - Number of Times + Auto Reset Feature has executed a Circuit Breaker + Restart on Port 1" + ::= { mibObjects 45 } + + trpCntGM2 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION "Master Auto Restart Count Port 2 - Number of Times + Auto Reset Feature has executed a Circuit Breaker + Restart on Port 2" + ::= { mibObjects 46 } + + trpCntGM3 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION "Master Auto Restart Count Port 3 - Number of Times + Auto Reset Feature has executed a Circuit Breaker + Restart on Port 3" + ::= { mibObjects 47 } + + trpCntGM4 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION "Master Auto Restart Count Port 4 - Number of Times + Auto Reset Feature has executed a Circuit Breaker + Restart on Port 4" + ::= { mibObjects 48 } + + trpCntGM5 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION "Master Auto Restart Count Port 5 - Number of Times + Auto Reset Feature has executed a Circuit Breaker + Restart on Port 5" + ::= { mibObjects 49 } + + trpCntGM6 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION "Master Auto Restart Count Port 6 - Number of Times + Auto Reset Feature has executed a Circuit Breaker + Restart on Port 6" + ::= { mibObjects 50 } + + trpCntGM7 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION "Master Auto Restart Count Port 7 - Number of Times + Auto Reset Feature has executed a Circuit Breaker + Restart on Port 7" + ::= { mibObjects 51 } + + trpCntGM8 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION "Master Auto Restart Count Port 8 - Number of Times + Auto Reset Feature has executed a Circuit Breaker + Restart on Port 8" + ::= { mibObjects 52 } + + trpCntBM1 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION "Master Ckt Breaker Auto Restart Fail Count Port + 1 - Number of Times Auto Reset Feature has failed + to restart (after 7 tries) a Circuit Breaker + on Port 1" + ::= { mibObjects 53 } + + trpCntBM2 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION "Master Ckt Breaker Auto Restart Fail Count Port + 2 - Number of Times Auto Reset Feature has failed + to restart (after 7 tries) a Circuit Breaker + on Port 2" + ::= { mibObjects 54 } + + trpCntBM3 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION "Master Ckt Breaker Auto Restart Fail Count Port + 3 - Number of Times Auto Reset Feature has failed + to restart (after 7 tries) a Circuit Breaker + on Port 3" + ::= { mibObjects 55 } + + trpCntBM4 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION "Master Ckt Breaker Auto Restart Fail Count Port + 4 - Number of Times Auto Reset Feature has failed + to restart (after 7 tries) a Circuit Breaker + on Port 4" + ::= { mibObjects 56 } + + trpCntBM5 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION "Master Ckt Breaker Auto Restart Fail Count Port + 5 - Number of Times Auto Reset Feature has failed + to restart (after 7 tries) a Circuit Breaker + on Port 5" + ::= { mibObjects 57 } + + trpCntBM6 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION "Master Ckt Breaker Auto Restart Fail Count Port + 6 - Number of Times Auto Reset Feature has failed + to restart (after 7 tries) a Circuit Breaker + on Port 6" + ::= { mibObjects 58 } + + trpCntBM7 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION "Master Ckt Breaker Auto Restart Fail Count Port + 7 - Number of Times Auto Reset Feature has failed + to restart (after 7 tries) a Circuit Breaker + on Port 7" + ::= { mibObjects 59 } + + trpCntBM8 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION "Master Ckt Breaker Auto Restart Fail Count Port + 8 - Number of Times Auto Reset Feature has failed + to restart (after 7 tries) a Circuit Breaker + on Port 8" + ::= { mibObjects 60 } + + + lostEthernetConnection TRAP-TYPE + ENTERPRISE mibObjects + DESCRIPTION "Lost Ethernet Connection" + ::= 0 + + masterPrimayPowerLost TRAP-TYPE + ENTERPRISE mibObjects + DESCRIPTION "Master Primary Power Lost" + ::= 1 + + masterSecondaryPowerLost TRAP-TYPE + ENTERPRISE mibObjects + DESCRIPTION "Master Secondary Power Lost" + ::= 2 + + gpsSignalLost TRAP-TYPE + ENTERPRISE mibObjects + DESCRIPTION "GPS Signal Lost" + ::= 3 + + masterTempatureError TRAP-TYPE + ENTERPRISE mibObjects + DESCRIPTION "Master Temperature Error" + ::= 4 + + masterCircuitBreakerTripCode TRAP-TYPE + ENTERPRISE mibObjects + DESCRIPTION "Master Circuit Breaker Trip Code - Master Breaker Tripped + Code: 1=Port 1, 2=Port2, 4=Port 3, 8=Port4, 16=Port5, + 32=Port6, 64=Port7, 128=Port8 Example: Code + 5 means Port 3 and Port 1 Tripped" + ::= 5 + + loginFailedAttempt TRAP-TYPE + ENTERPRISE mibObjects + DESCRIPTION "Login Failed Attempt" + ::= 6 + + settingsChanged TRAP-TYPE + ENTERPRISE mibObjects + DESCRIPTION "CTM Settings Changed" + ::= 7 + + masterPrimaryPowerOK TRAP-TYPE + ENTERPRISE mibObjects + DESCRIPTION "Master Primary Power OK" + ::= 10 + + masterSecondaryPowerOK TRAP-TYPE + ENTERPRISE mibObjects + DESCRIPTION "Master Secondary Power OK" + ::= 20 + + gpsSignalOK TRAP-TYPE + ENTERPRISE mibObjects + DESCRIPTION "GPS Signal OK" + ::= 30 + + tempatureOK TRAP-TYPE + ENTERPRISE mibObjects + DESCRIPTION "Temperature OK" + ::= 40 + + circuitBreakersOK TRAP-TYPE + ENTERPRISE mibObjects + DESCRIPTION "Circuit Breakers OK" + ::= 50 + + masterAutoRestartCBCompletedOK TRAP-TYPE + ENTERPRISE mibObjects + DESCRIPTION "Master Auto Restart CB Completed OK" + ::= 52 + + loginOK TRAP-TYPE + ENTERPRISE mibObjects + DESCRIPTION "Login OK" + ::= 60 + + resetComplete TRAP-TYPE + ENTERPRISE mibObjects + DESCRIPTION "Reset Complete" + ::= 80 + + ethernetConnectionRestored TRAP-TYPE + ENTERPRISE mibObjects + DESCRIPTION "Ethernet Connection Restored" + ::= 99 + + +END
\ No newline at end of file |