diff --git a/MIBS/comware/HH3C-USERLOG-MIB b/MIBS/comware/HH3C-USERLOG-MIB
new file mode 100644
index 0000000..8da7846
--- /dev/null
+++ b/MIBS/comware/HH3C-USERLOG-MIB
@@ -0,0 +1,805 @@
+-- =================================================================
+-- Copyright (C) 2003 New H3C Tech. Co., Ltd. All rights reserved.
+--
+-- Description:This MIB file is used for management of userlog
+-- information.
+-- Reference:
+-- Version: V1.1
+-- History:
+-- V1.0
+-- 31st Mar 2003
+-- tianli, initial version
+-- V1.1 2005-07-05
+-- Modify value range of hh3cUserlogNatAclNumber and hh3cUserlogFlowAclNumber
+-- by tanbo02122.
+-- Update file format by gaolong.
+-- =================================================================
+HH3C-USERLOG-MIB DEFINITIONS ::= BEGIN
+
+ IMPORTS
+ hh3cRhw
+ FROM HH3C-OID-MIB
+ OBJECT-GROUP, MODULE-COMPLIANCE
+ FROM SNMPv2-CONF
+ IpAddress, Integer32, Counter32, OBJECT-TYPE,
+ MODULE-IDENTITY
+ FROM SNMPv2-SMI;
+
+
+ hh3cUserLogMIB MODULE-IDENTITY
+ LAST-UPDATED "200304100000Z" -- April 10, 2003 at 00:00 GMT
+ ORGANIZATION
+ "New H3C Tech. Co., Ltd."
+ CONTACT-INFO
+ "Platform Team New H3C Tech. Co., Ltd.
+ Hai-Dian District Beijing P.R. China
+ http://www.h3c.com
+ Zip:100085
+ "
+ DESCRIPTION
+ "The HH3C-USERLOG-MIB contains objects to
+ Manage configuration and Monitor running state
+ for userlog feature."
+ ::= { hh3cRhw 18 }
+
+
+ hh3cUserlogObjects OBJECT IDENTIFIER ::= { hh3cUserLogMIB 1 }
+
+
+ hh3cUserlogNatObjects OBJECT IDENTIFIER ::= { hh3cUserlogObjects 1 }
+
+
+ hh3cUserlogNatVersion OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "NAT LOG version. Currently only version 1 is developed."
+ ::= { hh3cUserlogNatObjects 1 }
+
+
+ hh3cUserlogNatSyslog OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "
+ NAT LOG format.
+ If 1, LOG format is sysLog.
+ If 0, LOG format is UDP packet.
+ UDP packet is the default format, and is recommended.
+ "
+ ::= { hh3cUserlogNatObjects 2 }
+
+
+ hh3cUserlogNatSourceIP OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The Source IP address of NAT LOG UDP packet."
+ ::= { hh3cUserlogNatObjects 3 }
+
+
+ hh3cUserlogNatFlowBegin OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "
+ Log the NAT flow when it is created.
+ If 1, this function is enabled.
+ If 0, this function is disabled.
+ This function will be used when real-time monitor required.
+ "
+ ::= { hh3cUserlogNatObjects 4 }
+
+
+ hh3cUserlogNatActiveTime OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "
+ The active time for long-time existed NAT flow.
+ Unit: minute. Range: 10 minutes ~ 120 minutes.
+ When setting it, NAT flow can be logged after an interval of
+ active time.
+ This function will be used when real-time monitor required.
+ The default value 0 means real-time monitor function is disabled.
+ "
+ ::= { hh3cUserlogNatObjects 5 }
+
+
+ hh3cUserlogNatSlotCfgInfoTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Hh3cUserlogNatSlotCfgInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of NAT LOG configuration information for the
+ specified slot."
+ ::= { hh3cUserlogNatObjects 6 }
+
+
+ hh3cUserlogNatSlotCfgInfoEntry OBJECT-TYPE
+ SYNTAX Hh3cUserlogNatSlotCfgInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "NAT LOG Configuration Information Entry for a slot."
+ INDEX { hh3cUserlogNatCfgSlotNumber }
+ ::= { hh3cUserlogNatSlotCfgInfoTable 1 }
+
+
+ Hh3cUserlogNatSlotCfgInfoEntry ::=
+ SEQUENCE {
+ hh3cUserlogNatCfgSlotNumber
+ Integer32,
+ hh3cUserlogNatEnable
+ Integer32,
+ hh3cUserlogNatAclNumber
+ Integer32,
+ hh3cUserlogNatHostAddress
+ IpAddress,
+ hh3cUserlogNatUdpPort
+ Integer32
+ }
+
+ hh3cUserlogNatCfgSlotNumber OBJECT-TYPE
+ SYNTAX Integer32 (0..15)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Slot number. Specify which slot is configured with NAT LOG. "
+ ::= { hh3cUserlogNatSlotCfgInfoEntry 1 }
+
+
+ hh3cUserlogNatEnable OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "
+ The NAT LOG feature Enable status.
+ If 1, NAT LOG is enbled.
+ If 0, NAT LOG is disabled.
+ "
+ ::= { hh3cUserlogNatSlotCfgInfoEntry 2 }
+
+
+ hh3cUserlogNatAclNumber OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "
+ Access-list number.
+ The value 0 means no ACL is specified.
+ Only when NAT LOG is enabled, can ACL be configured.
+ Only NAT flow which match the ACL will be logged.
+ "
+ ::= { hh3cUserlogNatSlotCfgInfoEntry 3 }
+
+
+ hh3cUserlogNatHostAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The IP address of NAT LOG server. "
+ ::= { hh3cUserlogNatSlotCfgInfoEntry 4 }
+
+
+ hh3cUserlogNatUdpPort OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The UDP Port Number of NAT LOG UDP packet."
+ ::= { hh3cUserlogNatSlotCfgInfoEntry 5 }
+
+
+ hh3cUserlogNatSlotRunInfoTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Hh3cUserlogNatSlotRunInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of NAT LOG running information for the specified slot."
+ ::= { hh3cUserlogNatObjects 7 }
+
+
+ hh3cUserlogNatSlotRunInfoEntry OBJECT-TYPE
+ SYNTAX Hh3cUserlogNatSlotRunInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "NAT LOG Running Information Entry for a slot."
+ INDEX { hh3cUserlogNatRunSlotNumber }
+ ::= { hh3cUserlogNatSlotRunInfoTable 1 }
+
+
+ Hh3cUserlogNatSlotRunInfoEntry ::=
+ SEQUENCE {
+ hh3cUserlogNatRunSlotNumber
+ Integer32,
+ hh3cUserlogNatTotalEntries
+ Counter32,
+ hh3cUserlogNatTotalPackets
+ Counter32,
+ hh3cUserlogNatFailedEntries
+ Counter32,
+ hh3cUserlogNatFailedPackets
+ Counter32,
+ hh3cUserlogNatClearRunStat
+ Integer32
+ }
+
+ hh3cUserlogNatRunSlotNumber OBJECT-TYPE
+ SYNTAX Integer32 (0..15)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Slot number. Specify on which slot the NAT LOG statistics
+ displayed."
+ ::= { hh3cUserlogNatSlotRunInfoEntry 1 }
+
+
+ hh3cUserlogNatTotalEntries OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of NAT flow entries which are logged."
+ ::= { hh3cUserlogNatSlotRunInfoEntry 2 }
+
+
+ hh3cUserlogNatTotalPackets OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of NAT LOG UDP packets generated by the router."
+ ::= { hh3cUserlogNatSlotRunInfoEntry 3 }
+
+
+ hh3cUserlogNatFailedEntries OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of NAT flow entries failed in outputting."
+ ::= { hh3cUserlogNatSlotRunInfoEntry 4 }
+
+
+ hh3cUserlogNatFailedPackets OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of NAT LOG UDP packets failed in outputting."
+ ::= { hh3cUserlogNatSlotRunInfoEntry 5 }
+
+
+ hh3cUserlogNatClearRunStat OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "
+ Clear the running statistics for NAT LOG. Write-only.
+ If 1, the running statistics for NAT LOG is resetted.
+ Other value is invalid.
+ "
+ ::= { hh3cUserlogNatSlotRunInfoEntry 6 }
+
+
+ hh3cUserlogFlowObjects OBJECT IDENTIFIER ::= { hh3cUserlogObjects 2 }
+
+
+ hh3cUserlogFlowVersion OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "BAS FLOW LOG version. Currently only version 1 is developed."
+ ::= { hh3cUserlogFlowObjects 1 }
+
+
+ hh3cUserlogFlowSyslog OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "
+ BAS FLOW LOG format.
+ If 1, LOG format is sysLog.
+ If 0, LOG format is UDP packet.
+ UDP packet is the default format, and is recommended.
+ "
+ ::= { hh3cUserlogFlowObjects 2 }
+
+
+ hh3cUserlogFlowSourceIP OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The Source IP address of BAS FLOW LOG UDP packet."
+ ::= { hh3cUserlogFlowObjects 3 }
+
+
+ hh3cUserlogFlowFlowBegin OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "
+ Log the BAS flow when it is created.
+ If 1, this function is enabled.
+ If 0, this function is disabled.
+ This function will be used when real-time monitor required.
+ "
+ ::= { hh3cUserlogFlowObjects 4 }
+
+
+ hh3cUserlogFlowActiveTime OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "
+ The active time for long-time existed BAS flow.
+ Unit: minute. Range: 10 minutes ~ 120 minutes.
+ When setting it, BAS flow can be logged after an internal of
+ active time.
+ This function will be used when real-time monitor required.
+ The default value 0 means real-time monitor function is disabled.
+ "
+ ::= { hh3cUserlogFlowObjects 5 }
+
+
+ hh3cUserlogFlowSlotCfgInfoTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Hh3cUserlogFlowSlotCfgInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of BAS FLOW LOG configuration information for the
+ specified slot."
+ ::= { hh3cUserlogFlowObjects 6 }
+
+
+ hh3cUserlogFlowSlotCfgInfoEntry OBJECT-TYPE
+ SYNTAX Hh3cUserlogFlowSlotCfgInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "BAS FLOW LOG Configuration Information Entry for a slot."
+ INDEX { hh3cUserlogFlowCfgSlotNumber }
+ ::= { hh3cUserlogFlowSlotCfgInfoTable 1 }
+
+
+ Hh3cUserlogFlowSlotCfgInfoEntry ::=
+ SEQUENCE {
+ hh3cUserlogFlowCfgSlotNumber
+ Integer32,
+ hh3cUserlogFlowEnable
+ Integer32,
+ hh3cUserlogFlowAclNumber
+ Integer32,
+ hh3cUserlogFlowHostAddress
+ IpAddress,
+ hh3cUserlogFlowUdpPort
+ Integer32
+ }
+
+ hh3cUserlogFlowCfgSlotNumber OBJECT-TYPE
+ SYNTAX Integer32 (0..15)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Slot number. Specify which slot is configured with BAS FLOW LOG."
+ ::= { hh3cUserlogFlowSlotCfgInfoEntry 1 }
+
+
+ hh3cUserlogFlowEnable OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "
+ The BAS FLOW LOG feature Enable status.
+ If 1, BAS FLOW LOG is enbled.
+ If 0, BAS FLOW LOG is disabled.
+ "
+ ::= { hh3cUserlogFlowSlotCfgInfoEntry 2 }
+
+
+ hh3cUserlogFlowAclNumber OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "
+ Access-list number.
+ The value 0 means no ACL is specified.
+ Only when BAS FLOW LOG is enabled, can ACL be configured.
+ Only BAS flow which match the ACL will be logged.
+ "
+ ::= { hh3cUserlogFlowSlotCfgInfoEntry 3 }
+
+
+ hh3cUserlogFlowHostAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The IP address of BAS FLOW LOG server. "
+ ::= { hh3cUserlogFlowSlotCfgInfoEntry 4 }
+
+
+ hh3cUserlogFlowUdpPort OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The UDP Port Number of BAS FLOW LOG UDP packet."
+ ::= { hh3cUserlogFlowSlotCfgInfoEntry 5 }
+
+
+ hh3cUserlogFlowSlotRunInfoTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Hh3cUserlogFlowSlotRunInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of BAS FLOW LOG running information for the specified slot."
+ ::= { hh3cUserlogFlowObjects 7 }
+
+
+ hh3cUserlogFlowSlotRunInfoEntry OBJECT-TYPE
+ SYNTAX Hh3cUserlogFlowSlotRunInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Running Information Entry for a slot."
+ INDEX { hh3cUserlogFlowRunSlotNumber }
+ ::= { hh3cUserlogFlowSlotRunInfoTable 1 }
+
+
+ Hh3cUserlogFlowSlotRunInfoEntry ::=
+ SEQUENCE {
+ hh3cUserlogFlowRunSlotNumber
+ Integer32,
+ hh3cUserlogFlowTotalEntries
+ Counter32,
+ hh3cUserlogFlowTotalPackets
+ Counter32,
+ hh3cUserlogFlowFailedEntries
+ Counter32,
+ hh3cUserlogFlowFailedPackets
+ Counter32,
+ hh3cUserlogFlowClearRunStat
+ Integer32
+ }
+
+ hh3cUserlogFlowRunSlotNumber OBJECT-TYPE
+ SYNTAX Integer32 (0..15)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Slot number. Specify on which slot the BAS FLOW LOG
+ statistics displayed."
+ ::= { hh3cUserlogFlowSlotRunInfoEntry 1 }
+
+
+ hh3cUserlogFlowTotalEntries OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of BAS FLOW Entries which are logged."
+ ::= { hh3cUserlogFlowSlotRunInfoEntry 2 }
+
+
+ hh3cUserlogFlowTotalPackets OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of FLOW LOG UDP packet generated by the router."
+ ::= { hh3cUserlogFlowSlotRunInfoEntry 3 }
+
+
+ hh3cUserlogFlowFailedEntries OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of BAS FLOW entries failed in outputting. "
+ ::= { hh3cUserlogFlowSlotRunInfoEntry 4 }
+
+
+ hh3cUserlogFlowFailedPackets OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of BAS FLOW LOG UDP packet failed in outputting."
+ ::= { hh3cUserlogFlowSlotRunInfoEntry 5 }
+
+
+ hh3cUserlogFlowClearRunStat OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "
+ Clear the running statistics for FLOW LOG. Write-only.
+ If 1, the running statistics for FLOW LOG is resetted.
+ Other value is invalid.
+ "
+ ::= { hh3cUserlogFlowSlotRunInfoEntry 6 }
+
+
+ hh3cUserlogAccessObjects OBJECT IDENTIFIER ::= { hh3cUserlogObjects 3 }
+
+
+ hh3cUserlogAccessVersion OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "BAS ACCESS LOG version. Currently only version 1 is developed."
+ ::= { hh3cUserlogAccessObjects 1 }
+
+
+ hh3cUserlogAccessSyslog OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "
+ BAS ACCESS LOG format.
+ If 1, LOG format is sysLog;
+ If 0, LOG format is UDP packet.
+ UDP packet is the default format, and is recommended.
+ "
+ ::= { hh3cUserlogAccessObjects 2 }
+
+
+ hh3cUserlogAccessSourceIP OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The Source IP address of BAS ACCESS LOG UDP packet."
+ ::= { hh3cUserlogAccessObjects 3 }
+
+
+ hh3cUserlogAccessSlotCfgInfoTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Hh3cUserlogAccessSlotCfgInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of BAS ACCESS LOG configuration information for the specified slot."
+ ::= { hh3cUserlogAccessObjects 4 }
+
+
+ hh3cUserlogAccessSlotCfgInfoEntry OBJECT-TYPE
+ SYNTAX Hh3cUserlogAccessSlotCfgInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "BAS ACCESS LOG Configuration Information Entry for a slot."
+ INDEX { hh3cUserlogAccessCfgSlotNumber }
+ ::= { hh3cUserlogAccessSlotCfgInfoTable 1 }
+
+
+ Hh3cUserlogAccessSlotCfgInfoEntry ::=
+ SEQUENCE {
+ hh3cUserlogAccessCfgSlotNumber
+ Integer32,
+ hh3cUserlogAccessEnable
+ Integer32,
+ hh3cUserlogAccessHostAddress
+ IpAddress,
+ hh3cUserlogAccessUdpPort
+ Integer32
+ }
+
+ hh3cUserlogAccessCfgSlotNumber OBJECT-TYPE
+ SYNTAX Integer32 (0..15)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Slot number. Specify which slot is configured with BAS ACCESS LOG."
+ ::= { hh3cUserlogAccessSlotCfgInfoEntry 1 }
+
+
+ hh3cUserlogAccessEnable OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "
+ The BAS ACCESS LOG feature Enable status.
+ If 1, BAS ACCESS LOG is enbled.
+ If 0, BAS ACCESS LOG is disabled.
+ "
+ ::= { hh3cUserlogAccessSlotCfgInfoEntry 2 }
+
+
+ hh3cUserlogAccessHostAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The IP address of BAS ACCESS LOG server."
+ ::= { hh3cUserlogAccessSlotCfgInfoEntry 3 }
+
+
+ hh3cUserlogAccessUdpPort OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The UDP Port Number of BAS ACCESS LOG UDP packet."
+ ::= { hh3cUserlogAccessSlotCfgInfoEntry 4 }
+
+
+ hh3cUserlogAccessSlotRunInfoTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Hh3cUserlogAccessSlotRunInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of BAS ACCESS LOG running information for the specified slot."
+ ::= { hh3cUserlogAccessObjects 5 }
+
+
+ hh3cUserlogAccessSlotRunInfoEntry OBJECT-TYPE
+ SYNTAX Hh3cUserlogAccessSlotRunInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Running Information Entry for a slot."
+ INDEX { hh3cUserlogAccessRunSlotNumber }
+ ::= { hh3cUserlogAccessSlotRunInfoTable 1 }
+
+
+ Hh3cUserlogAccessSlotRunInfoEntry ::=
+ SEQUENCE {
+ hh3cUserlogAccessRunSlotNumber
+ Integer32,
+ hh3cUserlogAccessTotalEntries
+ Counter32,
+ hh3cUserlogAccessTotalPackets
+ Counter32,
+ hh3cUserlogAccessFailedEntries
+ Counter32,
+ hh3cUserlogAccessFailedPackets
+ Counter32,
+ hh3cUserlogAccessClearRunStat
+ Integer32
+ }
+
+ hh3cUserlogAccessRunSlotNumber OBJECT-TYPE
+ SYNTAX Integer32 (0..15)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Slot number. Specify on which slot the BAS ACCESS LOG statistics displayed."
+ ::= { hh3cUserlogAccessSlotRunInfoEntry 1 }
+
+
+ hh3cUserlogAccessTotalEntries OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of BAS ACCESS Records which are logged."
+ ::= { hh3cUserlogAccessSlotRunInfoEntry 2 }
+
+
+ hh3cUserlogAccessTotalPackets OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of ACCESS LOG UDP packet generated by the router."
+ ::= { hh3cUserlogAccessSlotRunInfoEntry 3 }
+
+
+ hh3cUserlogAccessFailedEntries OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of BAS ACCESS entries failed in outputting."
+ ::= { hh3cUserlogAccessSlotRunInfoEntry 4 }
+
+
+ hh3cUserlogAccessFailedPackets OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of BAS ACCESS LOG UDP packet failed in outputting."
+ ::= { hh3cUserlogAccessSlotRunInfoEntry 5 }
+
+
+ hh3cUserlogAccessClearRunStat OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "
+ Clear the running statistics for ACCESS LOG. Write-only.
+ If 1, the running statistics for ACCESS LOG is resetted.
+ Other value is invalid.
+ "
+ ::= { hh3cUserlogAccessSlotRunInfoEntry 6 }
+
+
+ hh3cUserlogNotifications OBJECT IDENTIFIER ::= { hh3cUserLogMIB 2 }
+
+
+ hh3cUserlogConformance OBJECT IDENTIFIER ::= { hh3cUserLogMIB 3 }
+
+
+ hh3cUserlogCompliances OBJECT IDENTIFIER ::= { hh3cUserlogConformance 1 }
+
+
+ hh3cUserlogCompliance MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION
+ "The compliance statement for entities which implement the
+ Userlog mib."
+ MODULE -- this module
+ MANDATORY-GROUPS { hh3cUserlogMandatoryGroup }
+ ::= { hh3cUserlogCompliances 1 }
+
+
+ hh3cUserlogGroups OBJECT IDENTIFIER ::= { hh3cUserlogConformance 2 }
+
+
+ hh3cUserlogMandatoryGroup OBJECT-GROUP
+ OBJECTS { hh3cUserlogNatEnable, hh3cUserlogNatHostAddress, hh3cUserlogNatUdpPort,
+ hh3cUserlogFlowEnable, hh3cUserlogFlowHostAddress, hh3cUserlogFlowUdpPort,
+ hh3cUserlogAccessEnable, hh3cUserlogAccessHostAddress, hh3cUserlogAccessUdpPort
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing mandatory Userlog information."
+ ::= { hh3cUserlogGroups 1 }
+
+
+ hh3cUserlogConfigGroup OBJECT-GROUP
+ OBJECTS { hh3cUserlogNatVersion, hh3cUserlogNatSyslog, hh3cUserlogNatSourceIP,
+ hh3cUserlogNatFlowBegin, hh3cUserlogNatActiveTime, hh3cUserlogNatCfgSlotNumber,
+ hh3cUserlogNatEnable, hh3cUserlogNatAclNumber, hh3cUserlogNatHostAddress,
+ hh3cUserlogNatUdpPort, hh3cUserlogFlowVersion, hh3cUserlogFlowSyslog,
+ hh3cUserlogFlowSourceIP, hh3cUserlogFlowFlowBegin, hh3cUserlogFlowActiveTime,
+ hh3cUserlogFlowCfgSlotNumber, hh3cUserlogFlowEnable, hh3cUserlogFlowAclNumber,
+ hh3cUserlogFlowHostAddress, hh3cUserlogFlowUdpPort, hh3cUserlogAccessVersion,
+ hh3cUserlogAccessSyslog, hh3cUserlogAccessSourceIP, hh3cUserlogAccessCfgSlotNumber,
+ hh3cUserlogAccessEnable, hh3cUserlogAccessHostAddress, hh3cUserlogAccessUdpPort
+ }
+ STATUS current
+ DESCRIPTION
+ "All configurable parameters of Userlog feature."
+ ::= { hh3cUserlogGroups 2 }
+
+
+ hh3cUserlogInfoGroup OBJECT-GROUP
+ OBJECTS { hh3cUserlogNatTotalEntries, hh3cUserlogNatTotalPackets,
+ hh3cUserlogNatFailedEntries, hh3cUserlogNatFailedPackets,
+ hh3cUserlogFlowTotalEntries, hh3cUserlogFlowTotalPackets,
+ hh3cUserlogFlowFailedEntries, hh3cUserlogFlowFailedPackets,
+ hh3cUserlogAccessTotalEntries, hh3cUserlogAccessTotalPackets,
+ hh3cUserlogAccessFailedEntries, hh3cUserlogAccessFailedPackets
+ }
+ STATUS current
+ DESCRIPTION
+ "All running information of Userlog feature."
+ ::= { hh3cUserlogGroups 3 }
+
+END