summaryrefslogtreecommitdiff
path: root/MIBS/cisco/OLD-CISCO-SYS-MIB
diff options
context:
space:
mode:
Diffstat (limited to 'MIBS/cisco/OLD-CISCO-SYS-MIB')
-rw-r--r--MIBS/cisco/OLD-CISCO-SYS-MIB1043
1 files changed, 1043 insertions, 0 deletions
diff --git a/MIBS/cisco/OLD-CISCO-SYS-MIB b/MIBS/cisco/OLD-CISCO-SYS-MIB
new file mode 100644
index 0000000..fcf85c0
--- /dev/null
+++ b/MIBS/cisco/OLD-CISCO-SYS-MIB
@@ -0,0 +1,1043 @@
+-- *****************************************************************
+-- OLD-CISCO-SYS-MIB.my: Cisco System MIB file
+--
+-- July 1994, Jeffrey T. Johnson
+--
+-- Copyright (c) 1994-1996 by cisco Systems, Inc.
+-- All rights reserved.
+--
+-- *****************************************************************
+--
+-- Prior to 10.2, Cisco's lsystem mib group contained a curious
+-- assortment of mib objects. For 10.2, in order to allow similar
+-- objects to be compiled separately with the mib compiler, the
+-- lsystem group was separated into an envmon group (lenv), a cpu
+-- group (lcpu), a memory group (lmem), and a system group (lsystem).
+-- In order to preserve the OBJECT IDENTIFIERS from release 10.1 to
+-- 10.2, however, all four groups are still based at { local 1 }.
+-- This is fine from the mib compiler point-of-view, but causes
+-- problems for some test tools which don't like the fact that
+-- lsystem, lenv, lmem, and lcpu all have the same OBJECT IDENTIFIER.
+-- In order to work around this problem, this file exists which
+-- is a combination of the four 10.2 "system" mibs, with everything
+-- falling under the lsystem group (as it did in 10.1).
+--
+-- This mib should only be used as a replacement for the four separate
+-- system mibs (OLD-CISCO-CPU.my, OLD-CISCO-ENVMON-MIB.my,
+-- OLD-CISCO-MEMORY-MIB.my, OLD-CISCO-SYSTEM-MIB.my) in test tool
+-- environments. The aforementioned mibs should always be used in
+-- code generation
+
+ OLD-CISCO-SYS-MIB DEFINITIONS ::= BEGIN
+
+ IMPORTS
+ IpAddress
+ FROM RFC1155-SMI
+ OBJECT-TYPE
+ FROM RFC-1212
+ DisplayString
+ FROM RFC1213-MIB
+ local
+ FROM CISCO-SMI;
+
+ lsystem OBJECT IDENTIFIER ::= { local 1 }
+
+ -- Local Variable Section
+
+ -- This section describes the local variables within the cisco
+ -- product line. Groups may or may not be present depending
+ -- on the software options present in the managed device.
+
+
+ -- Local System Group
+
+ -- This group is present in all products.
+
+ romId OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This variable contains a printable octet
+ string which contains the System Bootstrap
+ description and version identification."
+ ::= { lsystem 1 }
+
+ whyReload OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This variable contains a printable octet
+ string which contains the reason why the
+ system was last restarted."
+ ::= { lsystem 2 }
+
+ hostName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This variable represents the name of the
+ host in printable ascii characters."
+ ::= { lsystem 3 }
+
+ domainName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This variable is the domain portion of the
+ domain name of the host."
+ ::= { lsystem 4 }
+
+ authAddr OBJECT-TYPE
+ SYNTAX IpAddress
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This variable contains the last SNMP
+ authorization failure IP address."
+ ::= { lsystem 5 }
+
+ bootHost OBJECT-TYPE
+ SYNTAX IpAddress
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Contains the IP address of the host that
+ supplied the currently running software."
+ ::= { lsystem 6 }
+
+ ping OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS obsolete
+ DESCRIPTION
+ "The ping mib object is obsolete as of IOS 10.2
+ It has been superseded by the Cisco Ping MIB"
+ ::= { lsystem 7 }
+
+ freeMem OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS obsolete
+ DESCRIPTION
+ "The freeMem mib object is obsolete as of IOS 11.1
+ It has been replaced with the cisco memory pool mib"
+ ::= { lsystem 8 }
+
+ bufferElFree OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Contains the number of free buffer
+ elements."
+ ::= { lsystem 9 }
+
+ bufferElMax OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Contains the maximum number of buffer
+ elements."
+ ::= { lsystem 10 }
+
+ bufferElHit OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Contains the number of buffer element hits."
+ ::= { lsystem 11 }
+
+ bufferElMiss OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Contains the number of buffer element
+ misses."
+ ::= { lsystem 12 }
+
+ bufferElCreate OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Contains the number of buffer element
+ creates."
+ ::= { lsystem 13 }
+
+ bufferSmSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Contains the size of small buffers."
+ ::= { lsystem 14 }
+
+ bufferSmTotal OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Contains the total number of small buffers."
+ ::= { lsystem 15 }
+
+ bufferSmFree OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Contains the number of free small buffers."
+ ::= { lsystem 16 }
+
+ bufferSmMax OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Contains the maximum number of small
+ buffers."
+ ::= { lsystem 17 }
+
+ bufferSmHit OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Contains the number of small buffer hits."
+ ::= { lsystem 18 }
+
+ bufferSmMiss OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Contains the number of small buffer misses."
+ ::= { lsystem 19 }
+
+ bufferSmTrim OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Contains the number of small buffer trims."
+ ::= { lsystem 20 }
+
+ bufferSmCreate OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Contains the number of small buffer
+ creates."
+ ::= { lsystem 21 }
+
+ bufferMdSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Contains the size of medium buffers."
+ ::= { lsystem 22 }
+
+ bufferMdTotal OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Contains the total number of medium
+ buffers."
+ ::= { lsystem 23 }
+
+ bufferMdFree OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Contains the number of free medium buffers."
+ ::= { lsystem 24 }
+
+ bufferMdMax OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Contains the maximum number of medium
+ buffers."
+ ::= { lsystem 25 }
+
+ bufferMdHit OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Contains the number of medium buffer hits."
+ ::= { lsystem 26 }
+
+ bufferMdMiss OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Contains the number of medium buffer
+ misses."
+ ::= { lsystem 27 }
+
+ bufferMdTrim OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Contains the number of medium buffer trims."
+ ::= { lsystem 28 }
+
+ bufferMdCreate OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Contains the number of medium buffer
+ creates."
+ ::= { lsystem 29 }
+
+ bufferBgSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Contains the size of big buffers."
+ ::= { lsystem 30 }
+
+ bufferBgTotal OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Contains the total number of big buffers."
+ ::= { lsystem 31 }
+
+ bufferBgFree OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Contains the number of free big buffers."
+ ::= { lsystem 32 }
+
+ bufferBgMax OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Contains the maximum number of big buffers."
+ ::= { lsystem 33 }
+
+ bufferBgHit OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Contains the number of big buffer hits."
+ ::= { lsystem 34 }
+
+ bufferBgMiss OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Contains the number of big buffer misses."
+ ::= { lsystem 35 }
+
+ bufferBgTrim OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Contains the number of big buffer trims."
+ ::= { lsystem 36 }
+
+ bufferBgCreate OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Contains the number of big buffer creates."
+ ::= { lsystem 37 }
+
+ bufferLgSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Contains the size of large buffers."
+ ::= { lsystem 38 }
+
+ bufferLgTotal OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Contains the total number of large buffers."
+ ::= { lsystem 39 }
+
+ bufferLgFree OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Contains the number of free large buffers."
+ ::= { lsystem 40 }
+
+ bufferLgMax OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Contains the maximum number of large
+ buffers."
+ ::= { lsystem 41 }
+
+ bufferLgHit OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Contains the number of large buffer hits."
+ ::= { lsystem 42 }
+
+ bufferLgMiss OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Contains the number of large buffer misses."
+ ::= { lsystem 43 }
+
+ bufferLgTrim OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Contains the number of large buffer trims."
+ ::= { lsystem 44 }
+
+ bufferLgCreate OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Contains the number of large buffer
+ creates."
+ ::= { lsystem 45 }
+
+ bufferFail OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Count of the number of buffer allocation
+ failures."
+ ::= { lsystem 46 }
+
+ bufferNoMem OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Count of the number of buffer create
+ failures due to no free memory."
+ ::= { lsystem 47 }
+
+ netConfigAddr OBJECT-TYPE
+ SYNTAX IpAddress
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Holds the address of the host that supplied
+ the network-confg file."
+ ::= { lsystem 48 }
+
+ netConfigName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Holds the name of the network configuration
+ file."
+ ::= { lsystem 49 }
+
+ netConfigSet OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS write-only
+ STATUS mandatory
+ DESCRIPTION
+ "Cause the loading of a new network-confg
+ file using TFTP."
+ ::= { lsystem 50 }
+
+ hostConfigAddr OBJECT-TYPE
+ SYNTAX IpAddress
+ ACCESS read-only
+ STATUS obsolete
+ DESCRIPTION
+ "Contains the address of the host that
+ provided the host-config file."
+ ::= { lsystem 51 }
+
+ hostConfigName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS obsolete
+ DESCRIPTION
+ "Contains the name of the last configured
+ host-confg file."
+ ::= { lsystem 52 }
+
+ hostConfigSet OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS write-only
+ STATUS obsolete
+ DESCRIPTION
+ "Cause the loading of a new host-confg file
+ using TFTP."
+ ::= { lsystem 53 }
+
+ writeMem OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS write-only
+ STATUS mandatory
+ DESCRIPTION
+ "Write configuration into non-volatile memory
+ / erase config memory if 0."
+ ::= { lsystem 54 }
+
+ writeNet OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS write-only
+ STATUS mandatory
+ DESCRIPTION
+ "Write configuration to host using TFTP."
+ ::= { lsystem 55 }
+
+ busyPer OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "CPU busy percentage in the last 5 second
+ period. Not the last 5 realtime seconds but
+ the last 5 second period in the scheduler."
+ ::= { lsystem 56 }
+
+ avgBusy1 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "1 minute exponentially-decayed moving
+ average of the CPU busy percentage."
+ ::= { lsystem 57 }
+
+ avgBusy5 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "5 minute exponentially-decayed moving
+ average of the CPU busy percentage."
+ ::= { lsystem 58 }
+
+ idleCount OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "cisco internal variable. not to be used"
+ ::= { lsystem 59 }
+
+ idleWired OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "cisco internal variable. not to be used"
+ ::= { lsystem 60 }
+
+ ciscoContactInfo OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "cisco's name and address"
+ ::= { lsystem 61 }
+
+ bufferHgSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Contains the size of huge buffers."
+ ::= { lsystem 62 }
+
+ bufferHgTotal OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Contains the total number of huge buffers."
+ ::= { lsystem 63 }
+
+ bufferHgFree OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Contains the number of free huge buffers."
+ ::= { lsystem 64 }
+
+ bufferHgMax OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Contains the maximum number of huge
+ buffers."
+ ::= { lsystem 65 }
+
+ bufferHgHit OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Contains the number of huge buffer hits."
+ ::= { lsystem 66 }
+
+ bufferHgMiss OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Contains the number of huge buffer misses."
+ ::= { lsystem 67 }
+
+ bufferHgTrim OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Contains the number of huge buffer trims."
+ ::= { lsystem 68 }
+
+ bufferHgCreate OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Contains the number of huge buffer creates."
+ ::= { lsystem 69 }
+
+ netConfigProto OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Holds the protocol that supplied the
+ network-confg file."
+ ::= { lsystem 70 }
+
+ hostConfigProto OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Holds the protocol that supplied the host-
+ confg file."
+ ::= { lsystem 71 }
+
+ sysConfigAddr OBJECT-TYPE
+ SYNTAX IpAddress
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Holds the address of the host that supplied
+ the system boot image."
+ ::= { lsystem 72 }
+
+ sysConfigName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Holds the name of the system boot image."
+ ::= { lsystem 73 }
+
+ sysConfigProto OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Holds the protocol that supplied the system
+ boot image."
+ ::= { lsystem 74 }
+
+ sysClearARP OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS write-only
+ STATUS mandatory
+ DESCRIPTION
+ "Perform a clearing of the entire ARP cache
+ and invalidation of route caches."
+ ::= { lsystem 75 }
+
+ sysClearInt OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS write-only
+ STATUS mandatory
+ DESCRIPTION
+ "Clear interface given IfIndex as value."
+ ::= { lsystem 76 }
+
+ envPresent OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Is there an environmental monitor card in
+ this box?, 0 - No, 1-AGS card present, wrong
+ firmware, 2-AGS CARD present, firmware ok,
+ 3-7000 support"
+ ::= { lsystem 77 }
+
+ envTestPt1Descr OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Description of the test point 1. Typically
+ ambient air or the temperature of air
+ entering the router"
+ ::= { lsystem 78 }
+
+ envTestPt1Measure OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Current value of test point 1. Typically a
+ temperature in centigrade."
+ ::= { lsystem 79 }
+
+ envTestPt2Descr OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Description of the test point 2. Typically
+ airflow or the temperature of air leaving the
+ router"
+ ::= { lsystem 80 }
+
+ envTestPt2Measure OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Current value of test point 2. Typically a
+ temperature in centigrade."
+ ::= { lsystem 81 }
+
+ envTestPt3Descr OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Description of the test point 3. Typically
+ +5 volt"
+ ::= { lsystem 82 }
+
+ envTestPt3Measure OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Current value of test point 3. Typically the
+ value in millivolts of the +5v supply"
+ ::= { lsystem 83 }
+
+ envTestPt4Descr OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Description of the test point 4. Typically
+ +12 volt"
+ ::= { lsystem 84 }
+
+ envTestPt4Measure OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Current value of test point 4. Typically the
+ value in millivolts of the +12v supply"
+ ::= { lsystem 85 }
+
+ envTestPt5Descr OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Description of the test point 5. Typically
+ -12 volt"
+ ::= { lsystem 86 }
+
+ envTestPt5Measure OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Current value of test point 5. Typically the
+ value in millivolts of the -12v supply"
+ ::= { lsystem 87 }
+
+ envTestPt6Descr OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Description of the test point 6. Typically
+ -5 volt"
+ ::= { lsystem 88 }
+
+ envTestPt6Measure OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Current value of test point 6. Typically the
+ value in millivolts of the -5v supply"
+ ::= { lsystem 89 }
+
+ envTestPt1MarginVal OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Value at which the router will shutdown.
+ Typically the ambient air temperature that
+ will shut the router down. (e.g. 43)"
+ ::= { lsystem 90 }
+
+ envTestPt2MarginVal OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Value at which the router will shutdown.
+ Typically the airflow air temperature that
+ will shut the router down. (e.g. 58)"
+ ::= { lsystem 91 }
+
+ envTestPt3MarginPercent OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "+/- Percentage that will shut the router
+ down, (e.g. 10%) typically +5 volt"
+ ::= { lsystem 92 }
+
+ envTestPt4MarginPercent OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "+/- Percentage that will shut the router
+ down, (e.g. 15%) typically +12 volt"
+ ::= { lsystem 93 }
+
+ envTestPt5MarginPercent OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "+/- Percentage that will shut the router
+ down, (e.g. 15%) typically -12 volt"
+ ::= { lsystem 94 }
+
+ envTestPt6MarginPercent OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "+/- Percentage that will shut the router
+ down, (e.g. 10%) typically -5 volt"
+ ::= { lsystem 95 }
+
+ envTestPt1last OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Value of TestPt1 when last shutdown
+ occurred."
+ ::= { lsystem 96 }
+
+ envTestPt2last OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Value of TestPt2 when last shutdown
+ occurred."
+ ::= { lsystem 97 }
+
+ envTestPt3last OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Value of TestPt3 when last shutdown
+ occurred."
+ ::= { lsystem 98 }
+
+ envTestPt4last OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Value of TestPt4 when last shutdown
+ occurred."
+ ::= { lsystem 99 }
+
+ envTestPt5last OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Value of TestPt5 when last shutdown
+ occurred."
+ ::= { lsystem 100 }
+
+ envTestPt6last OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Value of TestPt6 when last shutdown
+ occurred."
+ ::= { lsystem 101 }
+
+ envTestPt1warn OBJECT-TYPE
+ SYNTAX INTEGER {
+ warning(1),
+ noWarning(2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Is this test point at a warning level?"
+ ::= { lsystem 102 }
+
+ envTestPt2warn OBJECT-TYPE
+ SYNTAX INTEGER {
+ warning(1),
+ noWarning(2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Is this test point at a warning level?"
+ ::= { lsystem 103 }
+
+ envTestPt3warn OBJECT-TYPE
+ SYNTAX INTEGER {
+ warning(1),
+ noWarning(2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Is this test point at a warning level?"
+ ::= { lsystem 104 }
+
+ envTestPt4warn OBJECT-TYPE
+ SYNTAX INTEGER {
+ warning(1),
+ noWarning(2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Is this test point at a warning level?"
+ ::= { lsystem 105 }
+
+ envTestPt5warn OBJECT-TYPE
+ SYNTAX INTEGER {
+ warning(1),
+ noWarning(2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Is this test point at a warning level?"
+ ::= { lsystem 106 }
+
+ envTestPt6warn OBJECT-TYPE
+ SYNTAX INTEGER {
+ warning(1),
+ noWarning(2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Is this test point at a warning level?"
+ ::= { lsystem 107 }
+
+ envFirmVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Description of Environmental Card firmware"
+ ::= { lsystem 108 }
+
+ envTechnicianID OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Technician ID"
+ ::= { lsystem 109 }
+
+ envType OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The type of environmental card"
+ ::= { lsystem 110 }
+
+ envBurnDate OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The calibration / burn in date"
+ ::= { lsystem 111 }
+
+ envSerialNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Serial Number of environmental monitor card"
+ ::= { lsystem 112 }
+
+
+ END