summaryrefslogtreecommitdiff
path: root/MIBS/cisco/CISCOSB-RLINVENTORYENT-MIB
diff options
context:
space:
mode:
Diffstat (limited to 'MIBS/cisco/CISCOSB-RLINVENTORYENT-MIB')
-rw-r--r--MIBS/cisco/CISCOSB-RLINVENTORYENT-MIB112
1 files changed, 112 insertions, 0 deletions
diff --git a/MIBS/cisco/CISCOSB-RLINVENTORYENT-MIB b/MIBS/cisco/CISCOSB-RLINVENTORYENT-MIB
new file mode 100644
index 0000000..a96d522
--- /dev/null
+++ b/MIBS/cisco/CISCOSB-RLINVENTORYENT-MIB
@@ -0,0 +1,112 @@
+CISCOSB-RLINVENTORYENT-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ switch001 FROM CISCOSB-MIB
+ Unsigned32, OBJECT-TYPE FROM SNMPv2-SMI
+ DisplayString FROM RFC1213-MIB;
+
+
+UnitIfindexType ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION "Unit or ifindex type."
+ SYNTAX INTEGER {
+ unit(0),
+ ifindex(1)
+}
+
+ rlInventoryEntTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RlInventoryEntEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "A table that contains INVENTORY entities in the system."
+ ::= { switch001 217 }
+
+
+ rlInventoryEntEntry OBJECT-TYPE
+ SYNTAX RlInventoryEntEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "An entry (conceptual row) in the rlInventoryEnvTable."
+ INDEX { rlInventoryEntUnitOrIfindex ,rlInventoryEntUnitIfindexID }
+ ::= { rlInventoryEntTable 1 }
+
+ RlInventoryEntEntry::= SEQUENCE {
+ rlInventoryEntUnitOrIfindex UnitIfindexType,
+ rlInventoryEntUnitIfindexID Unsigned32,
+ rlInventoryEntVendorID DisplayString,
+ rlInventoryEntPID DisplayString,
+ rlInventoryEntName DisplayString,
+ rlInventoryEntDescription DisplayString,
+ rlInventoryEntSerialNumber DisplayString,
+ rlInventoryEntUnitNum Unsigned32
+ }
+
+ rlInventoryEntUnitOrIfindex OBJECT-TYPE
+ SYNTAX UnitIfindexType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "this field will be equal to zero if this is a unit else 1 if this is a port."
+ ::= { rlInventoryEntEntry 1 }
+
+
+ rlInventoryEntUnitIfindexID OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "if rlInventoryEntUnitOrIfindex = 0 this field contain the unit number else if rlInventoryEntUnitOrIfindex = 1
+This field contain the if_index number."
+ ::= { rlInventoryEntEntry 2 }
+
+
+ rlInventoryEntVendorID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Vendor identification"
+ ::= { rlInventoryEntEntry 3 }
+
+ rlInventoryEntPID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Physical identification"
+ ::= { rlInventoryEntEntry 4}
+
+ rlInventoryEntName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Unit number of interface name"
+ ::= { rlInventoryEntEntry 5 }
+
+ rlInventoryEntDescription OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Description of the entity"
+ ::= { rlInventoryEntEntry 6}
+
+ rlInventoryEntSerialNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The serial number of the interface or unit."
+ ::= { rlInventoryEntEntry 7 }
+
+ rlInventoryEntUnitNum OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "if rlInventoryEntUnitOrIfindex = 1 this field contain the unit number that associated to this port"
+ ::= { rlInventoryEntEntry 8 }
+
+
+END
+
+
+
+
+
+
+
+