summaryrefslogtreecommitdiff
path: root/MIBS/cisco/CISCO-STACKWISE-MIB
diff options
context:
space:
mode:
Diffstat (limited to 'MIBS/cisco/CISCO-STACKWISE-MIB')
-rw-r--r--MIBS/cisco/CISCO-STACKWISE-MIB1842
1 files changed, 1842 insertions, 0 deletions
diff --git a/MIBS/cisco/CISCO-STACKWISE-MIB b/MIBS/cisco/CISCO-STACKWISE-MIB
new file mode 100644
index 0000000..3a69795
--- /dev/null
+++ b/MIBS/cisco/CISCO-STACKWISE-MIB
@@ -0,0 +1,1842 @@
+-- *******************************************************************
+-- CISCO-STACKWISE-MIB.my: Cisco StackWise MIB
+--
+-- Description of managed objects for the StackWise technology.
+--
+-- October 2005, Gunnar Lovblom
+--
+-- Copyright (c) 2005, 2008-2012,2016 by Cisco Systems, Inc.
+-- All rights reserved.
+-- ******************************************************************
+
+CISCO-STACKWISE-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ Unsigned32,
+ MODULE-IDENTITY,
+ NOTIFICATION-TYPE,
+ OBJECT-TYPE
+ FROM SNMPv2-SMI
+ NOTIFICATION-GROUP,
+ MODULE-COMPLIANCE,
+ OBJECT-GROUP
+ FROM SNMPv2-CONF
+ entPhysicalIndex
+ FROM ENTITY-MIB
+ ifIndex
+ FROM IF-MIB
+ TruthValue,
+ MacAddress,
+ TEXTUAL-CONVENTION
+ FROM SNMPv2-TC
+ SnmpAdminString
+ FROM SNMP-FRAMEWORK-MIB
+ EntPhysicalIndexOrZero
+ FROM CISCO-TC
+ ciscoMgmt
+ FROM CISCO-SMI;
+
+ciscoStackWiseMIB MODULE-IDENTITY
+ LAST-UPDATED "201604160000Z"
+ ORGANIZATION "Cisco Systems, Inc."
+ CONTACT-INFO
+ "Cisco Systems
+ Customer Service
+
+ Postal: 170 W Tasman Drive
+ San Jose, CA 95134
+
+ Tel: +1 800 553-NETS
+
+ E-mail: cs-dsbu@cisco.com"
+ DESCRIPTION
+ "This MIB module contain a collection of managed objects
+ that apply to network devices supporting the Cisco
+ StackWise(TM) technology.
+
+ The StackWise technology provides a method for collectively
+ utilizing a stack of switches to create a single switching
+ unit.
+
+ The data stack is used for switching data packets and, in
+ power stack, switches are connected by special stack power
+ cables to share power. Moreover, stackwise is the concept
+ for combining multiple systems to give an impression of a
+ single system so that is why both power stack and data stack
+ are supported by single MIB.
+
+ Terminology:
+ Stack - A collection of switches connected by the
+ Cisco StackWise technology.
+
+ Master - The switch that is managing the stack.
+
+ Member - A switch in the stack that is
+ NOT the stack master.
+
+ Ring - Components that makes up the connections
+ between the switches in order to create a
+ stack.
+
+ Stackport - A special physical connector used by the ring.
+ It is possible for a switch have more than
+ one stackport.
+
+ SDM - Switch Database Management.
+
+ Stack Power - A collection of switches connected by special
+ stack power cables to share the power of
+ inter-connected power supplies across all switches
+ requiring power. Stack Power is managed by a
+ single data stack.
+
+ Jack-Jack - It is a device that provides the Power Shelf
+ capabilities required for Stack Power on
+ the high-end.
+
+ POE - Power Over Ethernet
+
+ FEP - Front End Power Supply
+
+ SOC - Sustained Overload Condition
+
+ GLS - Graceful Load Shedding
+
+ ILS - Immediate Load Shedding
+
+ SRLS - System Ring Load Shedding
+
+ SSLS - System Star Load Shedding"
+ REVISION "201604160000Z"
+ DESCRIPTION
+ "Added following objects in cswGlobals
+ - cswStackDomainNum
+ - cswStackType
+ - cswStackBandWidth
+ Created following tables
+ - cswDistrStackLinkInfoTable
+ -cswDistrStackPhyPortInfoTable
+ Added cswStatusGroupRev2
+ Deprecated cswStatusGroupRev1
+ Added cswDistrStackLinkStatusGroup
+ Added cswDistrStackPhyPortStatusGroup
+ Added cswStackWiseMIBComplianceRev4 MIB COMPLIANCE
+ Deprecated cswStackWiseMIBComplianceRev3 MIB COMPLIANCE."
+ REVISION "201511240000Z"
+ DESCRIPTION
+ "Added following Objects in cswSwitchInfoTable
+ - cswSwitchPowerAllocated
+ Added following OBJECT-GROUP
+ - cswStackPowerAllocatedGroup
+ Deprecated cswStackWiseMIBComplianceRev2 MODULE-COMPLIANCE.
+ Added cswStackWiseMIBComplianceRev3 MODULE-COMPLIANCE."
+ REVISION "201112120000Z"
+ DESCRIPTION
+ "Modified 'cswSwitchRole' object."
+ REVISION "201002010000Z"
+ DESCRIPTION
+ "Added cswStackPowerStatusGroup, cswStackPowerSwitchStatusGroup,
+ cswStackPowerPortStatusGroup, cswStatusGroupRev1 and
+ cswStackPowerNotificationGroup.
+ Deprecated cswStackWiseMIBCompliance compliance statement.
+ Added cswStackWiseMIBComplianceRev1 compliance statement.
+ Deprecated cswStatusGroup because we deprecated
+ cswEnableStackNotifications"
+ REVISION "200806100000Z"
+ DESCRIPTION
+ "Modified 'cswSwitchState' object."
+ REVISION "200510120000Z"
+ DESCRIPTION
+ "Initial version of this MIB module."
+ ::= { ciscoMgmt 500 }
+
+CswPowerStackMode ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "This textual convention is used to describe the mode of the
+ power stack. Since the power stack could only run in either
+ power sharing or redundant mode so this TC will also have only
+ following valid values,
+ powerSharing(1) :When a power stack is running in power
+ sharing mode then all the power supplies
+ in the power stack contributes towards
+ the global power budget of the stack.
+
+ redundant(2) :If the user wants the power stack to run
+ in redundant mode then we will take the
+ capacity of the largest power supply in
+ the power stack out of power stack global
+ power budget pool.
+
+ powerSharingStrict(3):This mode is same as power sharing mode
+ but, in this mode, the available power
+ will always be more than the used power.
+
+ redundantStrict(4) :This mode is same as redundant mode but,
+ in this mode, the available power will
+ always be more than the used power."
+ SYNTAX INTEGER {
+ powerSharing(1),
+ redundant(2),
+ powerSharingStrict(3),
+ redundantStrict(4)
+ }
+
+CswPowerStackType ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "This textual conventions is used to describe the type of the
+ power stack. Since the power stack could only be configured in
+ a ring or star topology so this TC will have only following
+ valid values,
+ ring(1): The power stack has been formed by connecting
+ the switches in ring topology.
+ star(2): The power stack has been formed by connecting
+ the switches in star topology."
+ SYNTAX INTEGER {
+ ring(1),
+ star(2)
+ }
+ciscoStackWiseMIBNotifs OBJECT IDENTIFIER
+ ::= { ciscoStackWiseMIB 0 }
+
+ciscoStackWiseMIBObjects OBJECT IDENTIFIER
+ ::= { ciscoStackWiseMIB 1 }
+
+ciscoStackWiseMIBConform OBJECT IDENTIFIER
+ ::= { ciscoStackWiseMIB 2 }
+
+cswGlobals OBJECT IDENTIFIER
+ ::= { ciscoStackWiseMIBObjects 1 }
+
+cswStackInfo OBJECT IDENTIFIER
+ ::= { ciscoStackWiseMIBObjects 2 }
+
+cswStackPowerInfo OBJECT IDENTIFIER
+ ::= { ciscoStackWiseMIBObjects 3 }
+
+-- Textual Conventions
+
+CswSwitchNumber ::= TEXTUAL-CONVENTION
+ DISPLAY-HINT "d"
+ STATUS current
+ DESCRIPTION
+ "A unique value, greater than zero, for each switch in a group
+ of stackable switches."
+ SYNTAX Unsigned32 (1..4294967295)
+
+CswSwitchNumberOrZero ::= TEXTUAL-CONVENTION
+ DISPLAY-HINT "d"
+ STATUS current
+ DESCRIPTION
+ "A unique value, greater than or equal to zero, for each switch
+ in a group of stackable switches.
+
+ A value of zero means that the switch number can not be
+ determined. The value of zero is not unique."
+ SYNTAX Unsigned32 (0..4294967295)
+
+CswSwitchPriority ::= TEXTUAL-CONVENTION
+ DISPLAY-HINT "d"
+ STATUS current
+ DESCRIPTION
+ "A value, greater than or equal to zero, that defines the
+ priority of a switch in a group of stackable switches. The
+ higher the value, the higher the priority."
+ SYNTAX Unsigned32 (0..4294967295)
+
+-- Global objects pertinent to all switches
+
+cswMaxSwitchNum OBJECT-TYPE
+ SYNTAX CswSwitchNumber
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The maximum number of switches that can be configured on
+ this stack. This is also the maximum value that can be
+ set by the cswSwitchNumNextReload object."
+ ::= { cswGlobals 1 }
+
+cswMaxSwitchConfigPriority OBJECT-TYPE
+ SYNTAX CswSwitchPriority
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The maximum configurable priority for a switch in this stack.
+ Highest value equals highest priority. This is the highest
+ value that can be set by the cswSwitchSwPriority object."
+ ::= { cswGlobals 2 }
+
+cswRingRedundant OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A value of 'true' is returned when the stackports are
+ connected in such a way that it forms a redundant ring."
+ ::= { cswGlobals 3 }
+
+cswStackPowerInfoTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CswStackPowerInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table holds the information about all the power stacks in
+ a single data stack."
+ ::= { cswStackPowerInfo 1 }
+
+cswStackPowerInfoEntry OBJECT-TYPE
+ SYNTAX CswStackPowerInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in the cswStackPowerInfoTable for each of the power
+ stacks in a single data stack. This entry contains information
+ regarding the power stack."
+ INDEX { cswStackPowerStackNumber }
+ ::= { cswStackPowerInfoTable 1 }
+
+CswStackPowerInfoEntry ::= SEQUENCE {
+ cswStackPowerStackNumber Unsigned32,
+ cswStackPowerMode CswPowerStackMode,
+ cswStackPowerMasterMacAddress MacAddress,
+ cswStackPowerMasterSwitchNum Unsigned32,
+ cswStackPowerNumMembers Unsigned32,
+ cswStackPowerType CswPowerStackType,
+ cswStackPowerName SnmpAdminString
+}
+
+cswStackPowerStackNumber OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A unique value, greater than zero, to identify a power stack."
+ ::= { cswStackPowerInfoEntry 1 }
+
+cswStackPowerMode OBJECT-TYPE
+ SYNTAX CswPowerStackMode
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object specifies the information about the mode of the
+ power stack.
+ Power-sharing mode: All of the input power can be used for
+ loads, and the total available power appears as one huge power
+ supply. The power budget includes all power from all supplies.
+ No power is set aside for power supply failures, so if a power
+ supply fails, load shedding (shutting down of powered devices or
+ switches) might occur. This is the default.
+ Redundant mode: The largest power supply is removed from the
+ power pool to be used as backup power in case one of the other
+ power supplies fails. The available power budget is the total
+ power minus the largest power supply. This reduces the available
+ power in the pool for switches and powered devices to draw from,
+ but in case of a failure or an extreme power load, there is less
+ chance of having to shut down switches or powered devices. This
+ is the recommended operating mode if your system has enough
+ power.
+ In addition, you can configure each mode to run a strict power
+ budget or a non-strict (loose) power budget. If the mode is
+ strict, the stack power needs cannot exceed the available power.
+ When the power budgeted to devices reaches the maximum available
+ PoE power, power is denied to the next device seeking power. In
+ this mode the stack never goes into an over-budgeted power mode.
+ When the mode is non-strict, budgeted power is allowed to exceed
+ available power. This is normally not a problem because most
+ devices do not run at full power and the chances of all powered
+ devices in the stack requiring maximum power at the same time is
+ small."
+ ::= { cswStackPowerInfoEntry 2 }
+
+cswStackPowerMasterMacAddress OBJECT-TYPE
+ SYNTAX MacAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object indicates the Mac address of the power stack
+ master."
+ ::= { cswStackPowerInfoEntry 3 }
+
+cswStackPowerMasterSwitchNum OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object indicates the switch number of the power stack
+ master.
+ The value of this object would be zero if the power stack
+ master is not part of this data stack."
+ ::= { cswStackPowerInfoEntry 4 }
+
+cswStackPowerNumMembers OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object indicates the number of members in the power
+ stack."
+ ::= { cswStackPowerInfoEntry 5 }
+
+cswStackPowerType OBJECT-TYPE
+ SYNTAX CswPowerStackType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object indicates the topology of the power stack, that is,
+ whether the switch is running in RING or STAR topology."
+ ::= { cswStackPowerInfoEntry 6 }
+
+cswStackPowerName OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object specifies a unique name of this power stack. A
+ zero-length string indicates no name is assigned."
+ ::= { cswStackPowerInfoEntry 7 }
+
+
+cswStackPowerPortInfoTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CswStackPowerPortInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table contains information about the stack power ports.
+ There exists an entry in this table for each physical stack
+ power port."
+ ::= { cswStackPowerInfo 2 }
+
+cswStackPowerPortInfoEntry OBJECT-TYPE
+ SYNTAX CswStackPowerPortInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A conceptual row in the cswStackPowerPortInfoTable. This entry
+ contains information about a power stack port."
+ INDEX {
+ entPhysicalIndex,
+ cswStackPowerPortIndex
+ }
+ ::= { cswStackPowerPortInfoTable 1 }
+
+CswStackPowerPortInfoEntry ::= SEQUENCE {
+ cswStackPowerPortIndex Unsigned32,
+ cswStackPowerPortOperStatus INTEGER,
+ cswStackPowerPortNeighborMacAddress MacAddress,
+ cswStackPowerPortNeighborSwitchNum CswSwitchNumberOrZero,
+ cswStackPowerPortLinkStatus INTEGER,
+ cswStackPowerPortOverCurrentThreshold Unsigned32,
+ cswStackPowerPortName SnmpAdminString
+}
+
+cswStackPowerPortIndex OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A unique value, greater than zero, for each stack power port."
+ ::= { cswStackPowerPortInfoEntry 1 }
+
+cswStackPowerPortOperStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled(1),
+ disabled(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object is used to either set or unset the operational
+ status of the stack port. This object will have following valid
+ values,
+
+ enabled(1) : The port is enabled
+ disabled(2) : The port is forced down"
+ ::= { cswStackPowerPortInfoEntry 2 }
+
+cswStackPowerPortNeighborMacAddress OBJECT-TYPE
+ SYNTAX MacAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This objects indicates the port neighbor's Mac Address."
+ ::= { cswStackPowerPortInfoEntry 3 }
+
+cswStackPowerPortNeighborSwitchNum OBJECT-TYPE
+ SYNTAX CswSwitchNumberOrZero
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This objects indicates the port neighbor's switch number. If
+ either there is no switch connected or the neighbor is not
+ Jack-Jack then the value of this object is going to be 0."
+ ::= { cswStackPowerPortInfoEntry 4 }
+
+cswStackPowerPortLinkStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ up(1),
+ down(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object is used to describe the link status of the stack
+ port. This object will have following valid
+ values,
+
+ up(1) : The port is connected and operational
+ down(2): The port is either forced down or not connected"
+ ::= { cswStackPowerPortInfoEntry 5 }
+
+cswStackPowerPortOverCurrentThreshold OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "Amperes"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object is used to retrieve the over current threshold. The
+ stack power cables are limited to carry current up to the limit
+ retrieved by this object. The stack power cables would not be
+ able to function properly if either the input or output current
+ goes beyond the threshold retrieved by this object."
+ ::= { cswStackPowerPortInfoEntry 6 }
+
+cswStackPowerPortName OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object specifies a unique name of the stack power port as
+ shown on the face plate of the system. A zero-length string
+ indicates no name is assigned."
+ ::= { cswStackPowerPortInfoEntry 7 }
+
+
+cswEnableStackNotifications OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS deprecated
+ DESCRIPTION
+ "This object indicates whether the system generates the
+ notifications defined in this MIB or not. A value of
+ 'false' will prevent the notifications from being sent."
+ ::= { cswGlobals 4 }
+
+cswEnableIndividualStackNotifications OBJECT-TYPE
+ SYNTAX BITS {
+ stackPortChange(0),
+ stackNewMaster(1),
+ stackMismatch(2),
+ stackRingRedundant(3),
+ stackNewMember(4),
+ stackMemberRemoved(5),
+ stackPowerLinkStatusChanged(6),
+ stackPowerPortOperStatusChanged(7),
+ stackPowerVersionMismatch(8),
+ stackPowerInvalidTopology(9),
+ stackPowerBudgetWarning(10),
+ stackPowerInvalidInputCurrent(11),
+ stackPowerInvalidOutputCurrent(12),
+ stackPowerUnderBudget(13),
+ stackPowerUnbalancedPowerSupplies(14),
+ stackPowerInsufficientPower(15),
+ stackPowerPriorityConflict(16),
+ stackPowerUnderVoltage(17),
+ stackPowerGLS(18),
+ stackPowerILS(19),
+ stackPowerSRLS(20),
+ stackPowerSSLS(21),
+ stackMemberToBeReloadedForUpgrade(22)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object is used to enable/disable individual notifications
+ defined in this MIB module. Turning on a particular bit would
+ enable the corresponding trap and, similarly, turning off a
+ particular bit would disable the corresponding trap. The
+ following notifications are controlled by this object:
+
+ stackPortChange(0): enables/disables cswStackPortChange
+ notification.
+
+ stackNewMaster(1): enables/disables cswStackNewMember
+ notification.
+
+ stackMismatch(2): enables/disables cswStackMismatch
+ notification.
+
+ stackRingRedundant(3): enables/disables cswStackRingRedundant
+ notification.
+
+ stackNewMember(4): enables/disables cswStackNewMember
+ notification.
+
+ stackMemberRemoved(5): enables/disables cswStackMemberRemoved
+ notification.
+
+ stackPowerLinkStatusChanged(6): enables/disables
+ cswStackPowerPortLinkStatusChanged notification.
+
+ stackPowerPortOperStatusChanged(7): enables/disables
+ cswStackPowerPortOperStatusChanged notification.
+
+ stackPowerVersionMismatch(8): enables/disables
+ cswStackPowerVersionMismatch notification.
+
+ stackPowerInvalidTopology(9): enables/disables
+ cswStackPowerInvalidTopology notification
+
+ stackPowerBudgetWarning(10): enables/disables
+ cswStackPowerBudgetWarning notification.
+
+ stackPowerInvalidInputCurrent(11): enables/disables
+ cswStackPowerInvalidInputCurrent notification.
+
+ stackPowerInvalidOutputCurrent(12): enables/disables
+ cswStackPowerInvalidOutputCurrent notification.
+
+ stackPowerUnderBudget(13): enables/disables
+ cswStackPowerUnderBudget notification.
+
+ stackPowerUnbalancedPowerSupplies(14): enables/disables
+ cswStackPowerUnbalancedPowerSupplies notification.
+
+ stackPowerInsufficientPower(15): enables/disables
+ cswStackPowerInsufficientPower notification.
+
+ stackPowerPriorityConflict(16): enables/disables
+ cswStackPowerPriorityConflict notification.
+
+ stackPowerUnderVoltage(17): enables/disables
+ cswStackPowerUnderVoltage notification.
+
+ stackPowerGLS(18): enables/disables cswStackPowerGLS
+ notification.
+
+ stackPowerILS(19): enables/disabled cswStackPowerILS
+ notification.
+
+ stackPowerSRLS(20): enables/disables cswStackPowerSRLS
+ notification.
+
+ stackPowerSSLS(21): enables/disables cswStackPowerSSLS
+ notification.
+ stackMemberToBeReloadedForUpgrade(22): enables/disables
+ cswStackMemberToBeReloadedForUpgrade notification."
+ ::= { cswGlobals 5 }
+
+cswStackDomainNum OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object indicates distributed domain of the switch.Only
+ Switches with the same domain number can be in the same dist
+ ributed domain.0 means no switch domain configured."
+ ::= { cswGlobals 6 }
+
+cswStackType OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object indicates type of switch stack. value
+ of Switch virtual domain determines if switch is
+ distributed or conventional stack. 0 means stack
+ is conventional back side stack."
+ ::= { cswGlobals 7 }
+
+cswStackBandWidth OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object indicates stack bandwidth."
+ ::= { cswGlobals 8 }
+
+-- Switch Information Table
+
+cswSwitchInfoTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CswSwitchInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table contains information specific to switches in a
+ stack. Every switch with an entry in the entPhysicalTable
+ (ENTITY-MIB) whose entPhysicalClass is 'chassis' will have
+ an entry in this table."
+ ::= { cswStackInfo 1 }
+
+cswSwitchInfoEntry OBJECT-TYPE
+ SYNTAX CswSwitchInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A conceptual row in the cswSwitchInfoTable describing
+ a switch information."
+ INDEX { entPhysicalIndex }
+ ::= { cswSwitchInfoTable 1 }
+
+CswSwitchInfoEntry ::= SEQUENCE {
+ cswSwitchNumCurrent CswSwitchNumber,
+ cswSwitchNumNextReload CswSwitchNumberOrZero,
+ cswSwitchRole INTEGER,
+ cswSwitchSwPriority CswSwitchPriority,
+ cswSwitchHwPriority CswSwitchPriority,
+ cswSwitchState INTEGER,
+ cswSwitchMacAddress MacAddress,
+ cswSwitchSoftwareImage SnmpAdminString,
+ cswSwitchPowerBudget Unsigned32,
+ cswSwitchPowerCommited Unsigned32,
+ cswSwitchSystemPowerPriority Unsigned32,
+ cswSwitchPoeDevicesLowPriority Unsigned32,
+ cswSwitchPoeDevicesHighPriority Unsigned32,
+ cswSwitchPowerAllocated Unsigned32
+}
+
+cswSwitchNumCurrent OBJECT-TYPE
+ SYNTAX CswSwitchNumber
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object contains the current switch identification number.
+ This number should match any logical labeling on the switch.
+ For example, a switch whose interfaces are labeled
+ 'interface #3' this value should be 3."
+ ::= { cswSwitchInfoEntry 1 }
+
+cswSwitchNumNextReload OBJECT-TYPE
+ SYNTAX CswSwitchNumberOrZero
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object contains the cswSwitchNumCurrent to be
+ used at next reload. The maximum value for this object is
+ defined by the cswMaxSwitchNum object.
+
+ Note: This object will contain 0 and cannot be set if the
+ cswSwitchState value is other than 'ready'."
+ ::= { cswSwitchInfoEntry 2 }
+
+cswSwitchRole OBJECT-TYPE
+ SYNTAX INTEGER {
+ master(1),
+ member(2),
+ notMember(3),
+ standby(4)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object describes the function of the switch:
+
+ master - stack master.
+
+ member - active member of the stack.
+
+ notMember - none-active stack member, see
+ cswSwitchState for status.
+
+ standby - stack standby switch."
+ ::= { cswSwitchInfoEntry 3 }
+
+cswSwitchSwPriority OBJECT-TYPE
+ SYNTAX CswSwitchPriority
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A number containing the priority of a switch. The switch with
+ the highest priority will become the master. The maximum value
+ for this object is defined by the cswMaxSwitchConfigPriority
+ object.
+
+ If after a reload the value of cswMaxSwitchConfigPriority
+ changes to a smaller value, and the value of cswSwitchSwPriority
+ has been previously set to a value greater or equal to the
+ new cswMaxSwitchConfigPriority, then the SNMP agent must set
+ cswSwitchSwPriority to the new cswMaxSwitchConfigPriority.
+
+ Note: This object will contain the value of 0 if the
+ cswSwitchState value is other than 'ready'."
+ ::= { cswSwitchInfoEntry 4 }
+
+cswSwitchHwPriority OBJECT-TYPE
+ SYNTAX CswSwitchPriority
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object contains the hardware priority of a switch. If
+ two or more entries in this table have the same
+ cswSwitchSwPriority value during the master election time,
+ the switch with the highest cswSwitchHwPriority will become
+ the master.
+
+ Note: This object will contain the value of 0 if the
+ cswSwitchState value is other than 'ready'."
+ ::= { cswSwitchInfoEntry 5 }
+
+cswSwitchState OBJECT-TYPE
+ SYNTAX INTEGER {
+ waiting(1),
+ progressing(2),
+ added(3),
+ ready(4),
+ sdmMismatch(5),
+ verMismatch(6),
+ featureMismatch(7),
+ newMasterInit(8),
+ provisioned(9),
+ invalid(10),
+ removed(11)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current state of a switch:
+
+ waiting - Waiting for a limited time on other
+ switches in the stack to come online.
+
+ progressing - Master election or mismatch checks in
+ progress.
+
+ added - The switch is added to the stack.
+
+ ready - The switch is operational.
+
+ sdmMismatch - The SDM template configured on the master
+ is not supported by the new member.
+
+ verMismatch - The operating system version running on the
+ master is different from the operating
+ system version running on this member.
+
+ featureMismatch - Some of the features configured on the
+ master are not supported on this member.
+
+ newMasterInit - Waiting for the new master to finish
+ initialization after master switchover
+ (Master Re-Init).
+
+ provisioned - The switch is not an active member of the
+ stack.
+
+ invalid - The switch's state machine is in an
+ invalid state.
+
+ removed - The switch is removed from the stack."
+ ::= { cswSwitchInfoEntry 6 }
+
+cswSwitchMacAddress OBJECT-TYPE
+ SYNTAX MacAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The MAC address of the switch.
+
+ Note: This object will contain the value of 0000:0000:0000
+ if the cswSwitchState value is other than 'ready'."
+ ::= { cswSwitchInfoEntry 7 }
+
+cswSwitchSoftwareImage OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The software image type running on the switch.
+
+ Note: This object will contain an empty string if the
+ cswSwitchState value is other than 'ready'."
+ ::= { cswSwitchInfoEntry 8 }
+
+cswSwitchPowerBudget OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "Watts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object indicates the power budget of the switch."
+ ::= { cswSwitchInfoEntry 9 }
+
+cswSwitchPowerCommited OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "Watts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object indicates the power committed to the POE devices
+ connected to the switch."
+ ::= { cswSwitchInfoEntry 10 }
+
+cswSwitchSystemPowerPriority OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This specifies the system's power priority. In case of
+ a power failure then the system with the highest system
+ priority will be brought down last."
+ ::= { cswSwitchInfoEntry 11 }
+
+cswSwitchPoeDevicesLowPriority OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object specifies the priority of the system's low
+ priority POE devices."
+ ::= { cswSwitchInfoEntry 12 }
+
+cswSwitchPoeDevicesHighPriority OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object specifies the priority of the system's high
+ priority POE devices. In order to avoid losing the high
+ priority POE devices before the low priority POE devices,
+ this object's value must be greater than value of
+ cswSwitchPoeDevicesLowPriority."
+ ::= { cswSwitchInfoEntry 13 }
+
+cswSwitchPowerAllocated OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "Watts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object indicates the power committed to the POE devices
+ connected to the switch."
+ ::= { cswSwitchInfoEntry 14 }
+
+-- StackPort Information Table
+
+cswStackPortInfoTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CswStackPortInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table contains stackport specific information. There
+ exists an entry in this table for every physical stack
+ port that have an entry in the ifTable (IF-MIB)."
+ ::= { cswStackInfo 2 }
+
+cswStackPortInfoEntry OBJECT-TYPE
+ SYNTAX CswStackPortInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A conceptual row in the cswStackPortInfoTable. An entry
+ contains information about a stackport."
+ INDEX { ifIndex }
+ ::= { cswStackPortInfoTable 1 }
+
+CswStackPortInfoEntry ::= SEQUENCE {
+ cswStackPortOperStatus INTEGER,
+ cswStackPortNeighbor EntPhysicalIndexOrZero
+}
+
+cswStackPortOperStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ up(1),
+ down(2),
+ forcedDown(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The state of the stackport.
+
+ up - Connected and operational.
+
+ down - Not connected to a neighboring switch or
+ administrative down.
+
+ forcedDown - Shut down by stack manager due to mismatch or
+ stackport errors."
+ ::= { cswStackPortInfoEntry 1 }
+
+cswStackPortNeighbor OBJECT-TYPE
+ SYNTAX EntPhysicalIndexOrZero
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object contains the value of the entPhysicalIndex of the
+ switch's chassis to which this stackport is connected to. If
+ the stackport is not connected, the value 0 is returned."
+ ::= { cswStackPortInfoEntry 2 }
+
+-- Distributed Stack Link Information Table
+
+cswDistrStackLinkInfoTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CswDistrStackLinkInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Distributed Stack Link Information."
+ ::= { cswStackInfo 3 }
+
+cswDistrStackLinkInfoEntry OBJECT-TYPE
+ SYNTAX CswDistrStackLinkInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An Entry containing information about DSL link."
+ INDEX { entPhysicalIndex ,
+ cswDSLindex }
+ ::= { cswDistrStackLinkInfoTable 1 }
+
+CswDistrStackLinkInfoEntry ::= SEQUENCE {
+ cswDSLindex Unsigned32,
+ cswDistrStackLinkBundleOperStatus INTEGER
+
+}
+
+cswDSLindex OBJECT-TYPE
+ SYNTAX Unsigned32 (1..2)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This is index of the distributed stack link
+ with respect to each interface port"
+ ::= { cswDistrStackLinkInfoEntry 1 }
+
+cswDistrStackLinkBundleOperStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ up(1),
+ down(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The state of the stackLink.
+ up - Connected and operational.
+ down - Not connected or administrative down."
+ ::= { cswDistrStackLinkInfoEntry 2 }
+
+-- Distributed Stack Port Information Table
+
+cswDistrStackPhyPortInfoTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CswDistrStackPhyPortInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table contains objects for Distributed stack
+ Link information Table."
+ ::= { cswStackInfo 4 }
+
+cswDistrStackPhyPortInfoEntry OBJECT-TYPE
+ SYNTAX CswDistrStackPhyPortInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An Entry containing information about stack port that
+ is part of Distributed Stack Link."
+ INDEX { entPhysicalIndex,
+ cswDSLindex,
+ ifIndex
+ }
+ ::= { cswDistrStackPhyPortInfoTable 1 }
+
+CswDistrStackPhyPortInfoEntry ::= SEQUENCE {
+ cswDistrStackPhyPort SnmpAdminString,
+ cswDistrStackPhyPortOperStatus INTEGER,
+ cswDistrStackPhyPortNbr SnmpAdminString,
+ cswDistrStackPhyPortNbrsw EntPhysicalIndexOrZero
+
+}
+
+cswDistrStackPhyPort OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object indicates the name of distributed stack port."
+ ::= { cswDistrStackPhyPortInfoEntry 1 }
+
+cswDistrStackPhyPortOperStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ up(1),
+ down(2)
+
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The state of the distributed stackport.
+ up - Connected and operational.
+ down - Not connected to a neighboring switch or
+ administrative down."
+ ::= { cswDistrStackPhyPortInfoEntry 2 }
+
+cswDistrStackPhyPortNbr OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object indicates the name of
+ distributed stack port's neighbor."
+ ::= { cswDistrStackPhyPortInfoEntry 3 }
+
+cswDistrStackPhyPortNbrsw OBJECT-TYPE
+ SYNTAX EntPhysicalIndexOrZero
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object indicates the EntPhysicalIndex of
+ the distributed stack port's neigbor switch."
+ ::= { cswDistrStackPhyPortInfoEntry 4 }
+
+-- Notifications
+
+cswMIBNotifications OBJECT IDENTIFIER
+ ::= { ciscoStackWiseMIBNotifs 0 }
+
+cswStackPortChange NOTIFICATION-TYPE
+ OBJECTS {
+ ifIndex,
+ cswStackPortOperStatus,
+ cswSwitchNumCurrent
+ }
+ STATUS current
+ DESCRIPTION
+ "This notification is generated when the state
+ of a stack port has changed."
+ ::= { cswMIBNotifications 1 }
+
+cswStackNewMaster NOTIFICATION-TYPE
+ OBJECTS { cswSwitchNumCurrent }
+ STATUS current
+ DESCRIPTION
+ "This notification is generated when a new master has been
+ elected. The notification will contain the cswSwitchNumCurrent
+ object to indicate the new master ID."
+ ::= { cswMIBNotifications 2 }
+
+cswStackMismatch NOTIFICATION-TYPE
+ OBJECTS {
+ cswSwitchState,
+ cswSwitchNumCurrent
+ }
+ STATUS current
+ DESCRIPTION
+ "This notification is generated when a new member attempt
+ to join the stack but was denied due to a mismatch. The
+ cswSwitchState object will indicate the type of mismatch."
+ ::= { cswMIBNotifications 3 }
+
+cswStackRingRedundant NOTIFICATION-TYPE
+ OBJECTS { cswRingRedundant }
+ STATUS current
+ DESCRIPTION
+ "This notification is generated when the redundancy of the
+ ring has changed."
+ ::= { cswMIBNotifications 4 }
+
+cswStackNewMember NOTIFICATION-TYPE
+ OBJECTS { cswSwitchNumCurrent }
+ STATUS current
+ DESCRIPTION
+ "This notification is generated when a new member joins the
+ stack."
+ ::= { cswMIBNotifications 5 }
+
+cswStackMemberRemoved NOTIFICATION-TYPE
+ OBJECTS { cswSwitchNumCurrent }
+ STATUS current
+ DESCRIPTION
+ "This notification is generated when a member is removed
+ from the stack."
+ ::= { cswMIBNotifications 6 }
+
+cswStackPowerPortLinkStatusChanged NOTIFICATION-TYPE
+ OBJECTS {
+ cswStackPowerPortLinkStatus,
+ cswSwitchNumCurrent,
+ cswStackPowerPortName
+ }
+ STATUS current
+ DESCRIPTION
+ "This notification is generated when the link status of a stack
+ power port is changed from up to down or down to up. This
+ notification is for informational purposes only and no action
+ is required. cswStackPowerPortLinkStatus indicates link status
+ of the stack power ports. cswSwitchNumCurrent indicates the
+ switch number of the system. cswStackPowerPortName specifies a
+ unique name of the stack power port as shown on the face plate
+ of the system."
+ ::= { cswMIBNotifications 7 }
+
+cswStackPowerPortOperStatusChanged NOTIFICATION-TYPE
+ OBJECTS {
+ cswSwitchNumCurrent,
+ cswStackPowerPortOperStatus,
+ cswStackPowerPortName
+ }
+ STATUS current
+ DESCRIPTION
+ "This notification is generated when the operational status of a
+ stack power port is changed from enabled to disabled or from
+ disabled to enabled. This notification is for informational
+ purposes only and no action is required. cswSwitchNumCurrent
+ indicates the switch number of the system.
+ cswStackPowerPortOperStatus indicates operational status
+ of the stack power ports. cswStackPowerPortName specifies
+ a unique name of the stack power port as shown on the face
+ plate of the system."
+ ::= { cswMIBNotifications 8 }
+
+cswStackPowerVersionMismatch NOTIFICATION-TYPE
+ OBJECTS { cswSwitchNumCurrent }
+ STATUS current
+ DESCRIPTION
+ "This notification is generated when the major version of the
+ stack power protocol is different from the other members of the
+ power stack. Upon receiving this notification, the user should
+ make sure that he/she is using the same software version on all
+ the members of the same power stack. cswSwitchNumCurrent
+ indicates the switch number of the system seeing the power
+ stack version mismatch."
+ ::= { cswMIBNotifications 9 }
+
+cswStackPowerInvalidTopology NOTIFICATION-TYPE
+ OBJECTS { cswSwitchNumCurrent }
+ STATUS current
+ DESCRIPTION
+ "This notification is generated when an invalid stack power
+ topology is discovered by a switch. cswSwitchNumCurrent
+ indicates the switch number of the system where the invalid
+ topology is discovered."
+ ::= { cswMIBNotifications 10 }
+
+cscwStackPowerBudgetWarrning NOTIFICATION-TYPE
+ OBJECTS { cswSwitchNumCurrent }
+ STATUS current
+ DESCRIPTION
+ "This notification is generated when the switch power budget is
+ more than 1000W above its power supplies rated power output.
+ cswSwitchNumCurrent indicates the switch number of the system
+ where the invalid power budget has been detected."
+ ::= { cswMIBNotifications 11 }
+
+cswStackPowerInvalidInputCurrent NOTIFICATION-TYPE
+ OBJECTS {
+ cswSwitchNumCurrent,
+ cswStackPowerPortOverCurrentThreshold,
+ cswStackPowerPortName
+ }
+ STATUS current
+ DESCRIPTION
+ "This notification is generated when the input current in the
+ stack power cable is over the limit of the threshold retrieved
+ by the agent through cswStackPowerPortOverCurrentThreshold
+ object. Upon receiving this notification, the user should add a
+ power supply to the system whose switch number is generated
+ with this notification. cswSwitchNumCurrent
+ indicates the switch number of the system.
+ cswStackPowerPortOverCurrentThreshold indicates the over current
+ threshold of power stack cables. cswStackPowerPortName specifies
+ a unique name of the stack power port as shown on the face
+ plate of the system."
+ ::= { cswMIBNotifications 12 }
+
+cswStackPowerInvalidOutputCurrent NOTIFICATION-TYPE
+ OBJECTS {
+ cswSwitchNumCurrent,
+ cswStackPowerPortOverCurrentThreshold,
+ cswStackPowerPortName
+ }
+ STATUS current
+ DESCRIPTION
+ "This notification is generated when the output current in the
+ stack power cable is over the limit of the threshold retrieved
+ by the agent through cswStackPowerPortOverCurrentThreshold
+ object. Upon receiving this notification, the user should
+ remove a power supply from the system whose switch number is
+ generated with this notification. cswSwitchNumCurrent
+ indicates the switch number of the system.
+ cswStackPowerPortOverCurrentThreshold indicates the over current
+ threshold of power stack cables. cswStackPowerPortName specifies
+ a unique name of the stack power port as shown on the face
+ plate of the system."
+ ::= { cswMIBNotifications 13 }
+
+cswStackPowerUnderBudget NOTIFICATION-TYPE
+ OBJECTS { cswSwitchNumCurrent }
+ STATUS current
+ DESCRIPTION
+ "This notification is generated when the switch's budget is less
+ than maximum possible switch power consumption.
+ cswSwitchNumCurrent indicates the switch number of the system
+ that is running with the power budget less than the power
+ consumption."
+ ::= { cswMIBNotifications 14 }
+
+cswStackPowerUnbalancedPowerSupplies NOTIFICATION-TYPE
+ OBJECTS { cswStackPowerName }
+ STATUS current
+ DESCRIPTION
+ "This notification is generated when the switch has no power
+ supply but another switch in the same stack has more than one
+ power supplies. cswStackPowerName specifies a unique name of the
+ power stack where the unbalanced power supplies are detected."
+ ::= { cswMIBNotifications 15 }
+
+cswStackPowerInsufficientPower NOTIFICATION-TYPE
+ OBJECTS { cswStackPowerName }
+ STATUS current
+ DESCRIPTION
+ "This notification is generated when the switch's power stack
+ does not have enough power to bring up all the switches in the
+ power stack. cswStackPowerName specifies a unique name of the
+ power stack where insufficient power condition is detected."
+ ::= { cswMIBNotifications 16 }
+
+cswStackPowerPriorityConflict NOTIFICATION-TYPE
+ OBJECTS { cswStackPowerName }
+ STATUS current
+ DESCRIPTION
+ "This notification is generated when the switch's power
+ priorities are conflicting with power priorities of another
+ switch in the same power stack. cswStackPowerPortName specifies
+ the unique name of the power stack where the conflicting power
+ priorities are detected."
+ ::= { cswMIBNotifications 17 }
+
+cswStackPowerUnderVoltage NOTIFICATION-TYPE
+ OBJECTS { cswSwitchNumCurrent }
+ STATUS current
+ DESCRIPTION
+ "This notification is generated when the switch had an under
+ voltage condition on last boot up. cswSwitchNumCurrent
+ indicates the switch number of the system that was forced
+ down with the under voltage condition."
+ ::= { cswMIBNotifications 18 }
+
+cswStackPowerGLS NOTIFICATION-TYPE
+ OBJECTS { cswSwitchNumCurrent }
+ STATUS current
+ DESCRIPTION
+ "This notification is generated when the switch had to shed
+ loads based on a sustained over load (SOC) condition.
+ cswSwitchNumCurrent indicates the switch number of the system
+ that goes through graceful load shedding."
+ ::= { cswMIBNotifications 19 }
+
+cswStackPowerILS NOTIFICATION-TYPE
+ OBJECTS { cswSwitchNumCurrent }
+ STATUS current
+ DESCRIPTION
+ "This notification is generated when the switch had to shed
+ loads based on power supply fail condition. cswSwitchNumCurrent
+ indicates the switch number of the system that goes through
+ immediate load shedding."
+ ::= { cswMIBNotifications 20 }
+
+cswStackPowerSRLS NOTIFICATION-TYPE
+ OBJECTS { cswSwitchNumCurrent }
+ STATUS current
+ DESCRIPTION
+ "This notification is generated when the switch had to shed
+ loads based on loss of a system in ring topology.
+ cswSwitchNumCurrent indicates the switch number of the system
+ that detects the loss of system in ring topology."
+ ::= { cswMIBNotifications 21 }
+
+cswStackPowerSSLS NOTIFICATION-TYPE
+ OBJECTS { cswSwitchNumCurrent }
+ STATUS current
+ DESCRIPTION
+ "This notification is generated when the switch had to shed
+ loads based on loss of a system in star topology.
+ cswSwitchNumCurrent indicates the switch number of the system
+ that detects the loss of system in star topology."
+ ::= { cswMIBNotifications 22 }
+
+cswStackMemberToBeReloadedForUpgrade NOTIFICATION-TYPE
+ OBJECTS { cswSwitchNumCurrent }
+ STATUS current
+ DESCRIPTION
+ "This notification is generated when a member is to be reloaded
+ for upgrade."
+ ::= { cswMIBNotifications 23 }
+-- Conformance and Compliance statements
+
+cswStackWiseMIBCompliances OBJECT IDENTIFIER
+ ::= { ciscoStackWiseMIBConform 1 }
+
+cswStackWiseMIBGroups OBJECT IDENTIFIER
+ ::= { ciscoStackWiseMIBConform 2 }
+
+cswStackWiseMIBCompliance MODULE-COMPLIANCE
+ STATUS deprecated
+ DESCRIPTION
+ "The compliance statement for entities that implement the
+ CISCO-STACKWISE-MIB."
+ MODULE -- this module
+ MANDATORY-GROUPS {
+ cswStatusGroup,
+ cswNotificationGroup
+ }
+
+ OBJECT cswSwitchSwPriority
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT cswSwitchNumNextReload
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+ ::= { cswStackWiseMIBCompliances 1 }
+
+cswStackWiseMIBComplianceRev1 MODULE-COMPLIANCE
+ STATUS deprecated
+ DESCRIPTION
+ "The compliance statements for entities described in
+ CISCO-STACKWISE-MIB. Stack Power entities are added in this
+ revision."
+ MODULE -- this module
+ MANDATORY-GROUPS {
+ cswNotificationGroup,
+ cswStatusGroupRev1,
+ cswStackPowerEnableNotificationGroup
+ }
+
+ GROUP cswStackPowerStatusGroup
+ DESCRIPTION
+ "This group is only mandatory for systems which support stack
+ power."
+
+ GROUP cswStackPowerSwitchStatusGroup
+ DESCRIPTION
+ "This group is only mandatory for systems which support stack
+ power."
+
+ GROUP cswStackPowerPortStatusGroup
+ DESCRIPTION
+ "This group is only mandatory for systems which support stack
+ power."
+
+ GROUP cswStackPowerNotificationGroup
+ DESCRIPTION
+ "This group is only mandatory for systems which support stack
+ power."
+ ::= { cswStackWiseMIBCompliances 2 }
+
+cswStackWiseMIBComplianceRev2 MODULE-COMPLIANCE
+ STATUS deprecated
+ DESCRIPTION
+ "The compliance statements for entities described in
+ CISCO-STACKWISE-MIB. Stack Power entities are added in this
+ revision."
+ MODULE -- this module
+ MANDATORY-GROUPS {
+ cswNotificationGroup,
+ cswNotificationGroupSup1,
+ cswStatusGroupRev1,
+ cswStackPowerEnableNotificationGroup
+ }
+
+ GROUP cswStackPowerStatusGroup
+ DESCRIPTION
+ "This group is only mandatory for systems which support stack
+ power."
+
+ GROUP cswStackPowerSwitchStatusGroup
+ DESCRIPTION
+ "This group is only mandatory for systems which support stack
+ power."
+
+ GROUP cswStackPowerPortStatusGroup
+ DESCRIPTION
+ "This group is only mandatory for systems which support stack
+ power."
+
+ GROUP cswStackPowerNotificationGroup
+ DESCRIPTION
+ "This group is only mandatory for systems which support stack
+ power."
+ ::= { cswStackWiseMIBCompliances 3 }
+
+cswStackWiseMIBComplianceRev3 MODULE-COMPLIANCE
+ STATUS deprecated
+ DESCRIPTION
+ "The compliance statements for entities described in
+ CISCO-STACKWISE-MIB. Stack Power entities are added in this
+ revision."
+ MODULE -- this module
+ MANDATORY-GROUPS {
+ cswNotificationGroup,
+ cswNotificationGroupSup1,
+ cswStatusGroupRev1,
+ cswStackPowerEnableNotificationGroup
+ }
+
+ GROUP cswStackPowerStatusGroup
+ DESCRIPTION
+ "This group is only mandatory for systems which support stack
+ power."
+
+ GROUP cswStackPowerSwitchStatusGroup
+ DESCRIPTION
+ "This group is only mandatory for systems which support stack
+ power."
+
+ GROUP cswStackPowerPortStatusGroup
+ DESCRIPTION
+ "This group is only mandatory for systems which support stack
+ power."
+
+ GROUP cswStackPowerNotificationGroup
+ DESCRIPTION
+ "This group is only mandatory for systems which support stack
+ power."
+
+ GROUP cswStackPowerAllocatedGroup
+ DESCRIPTION
+ "This group is only mandatory for systems which support stack
+ power allocation information."
+ OBJECT cswStackPowerMode
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT cswStackPowerName
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT cswStackPowerPortOperStatus
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT cswStackPowerPortOverCurrentThreshold
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT cswEnableIndividualStackNotifications
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT cswSwitchNumNextReload
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT cswSwitchSwPriority
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT cswSwitchSystemPowerPriority
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT cswSwitchPoeDevicesLowPriority
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT cswSwitchPoeDevicesHighPriority
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+ ::= { cswStackWiseMIBCompliances 4 }
+
+cswStackWiseMIBComplianceRev4 MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION
+ "The compliance statements for entities described in
+ CISCO-STACKWISE-MIB. Stack Global entities are added in this
+ revision."
+ MODULE -- this module
+ MANDATORY-GROUPS {
+ cswNotificationGroup,
+ cswNotificationGroupSup1,
+ cswStatusGroupRev2,
+ cswStackPowerEnableNotificationGroup,
+ cswDistrStackLinkStatusGroup,
+ cswDistrStackPhyPortStatusGroup
+ }
+
+ GROUP cswStackPowerStatusGroup
+ DESCRIPTION
+ "This group is only mandatory for systems which support stack
+ power."
+
+ GROUP cswStackPowerSwitchStatusGroup
+ DESCRIPTION
+ "This group is only mandatory for systems which support stack
+ power."
+
+ GROUP cswStackPowerPortStatusGroup
+ DESCRIPTION
+ "This group is only mandatory for systems which support stack
+ power."
+
+ GROUP cswStackPowerNotificationGroup
+ DESCRIPTION
+ "This group is only mandatory for systems which support stack
+ power."
+
+ GROUP cswStackPowerAllocatedGroup
+ DESCRIPTION
+ "This group is only mandatory for systems which support stack
+ power allocation information."
+
+ OBJECT cswStackPowerMode
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT cswStackPowerName
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT cswStackPowerPortOperStatus
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT cswStackPowerPortOverCurrentThreshold
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT cswEnableIndividualStackNotifications
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT cswSwitchNumNextReload
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT cswSwitchSwPriority
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT cswSwitchSystemPowerPriority
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT cswSwitchPoeDevicesLowPriority
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT cswSwitchPoeDevicesHighPriority
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+ ::= { cswStackWiseMIBCompliances 5 }
+
+-- units of conformance
+
+cswStatusGroup OBJECT-GROUP
+ OBJECTS {
+ cswMaxSwitchNum,
+ cswMaxSwitchConfigPriority,
+ cswRingRedundant,
+ cswEnableStackNotifications,
+ cswSwitchNumCurrent,
+ cswSwitchNumNextReload,
+ cswSwitchRole,
+ cswSwitchSwPriority,
+ cswSwitchHwPriority,
+ cswSwitchState,
+ cswSwitchMacAddress,
+ cswSwitchSoftwareImage,
+ cswStackPortOperStatus,
+ cswStackPortNeighbor,
+ cswStackPowerType
+ }
+ STATUS deprecated
+ DESCRIPTION
+ "A collection of objects that are used for control and
+ status."
+ ::= { cswStackWiseMIBGroups 1 }
+
+cswNotificationGroup NOTIFICATION-GROUP
+ NOTIFICATIONS {
+ cswStackPortChange,
+ cswStackNewMaster,
+ cswStackMismatch,
+ cswStackRingRedundant,
+ cswStackNewMember,
+ cswStackMemberRemoved
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of notifications that are required."
+ ::= { cswStackWiseMIBGroups 2 }
+
+cswStatusGroupRev1 OBJECT-GROUP
+ OBJECTS {
+ cswMaxSwitchNum,
+ cswMaxSwitchConfigPriority,
+ cswRingRedundant,
+ cswSwitchNumCurrent,
+ cswSwitchNumNextReload,
+ cswSwitchRole,
+ cswSwitchSwPriority,
+ cswSwitchHwPriority,
+ cswSwitchState,
+ cswSwitchMacAddress,
+ cswSwitchSoftwareImage
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects that are used for control and
+ status."
+ ::= { cswStackWiseMIBGroups 3 }
+
+cswStackPowerStatusGroup OBJECT-GROUP
+ OBJECTS {
+ cswStackPowerMode,
+ cswStackPowerMasterMacAddress,
+ cswStackPowerMasterSwitchNum,
+ cswStackPowerNumMembers,
+ cswStackPowerType,
+ cswStackPowerName
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of stack power objects that are used for control
+ and status of power stack."
+ ::= { cswStackWiseMIBGroups 4 }
+
+cswStackPowerSwitchStatusGroup OBJECT-GROUP
+ OBJECTS {
+ cswSwitchPowerBudget,
+ cswSwitchPowerCommited,
+ cswSwitchSystemPowerPriority,
+ cswSwitchPoeDevicesLowPriority,
+ cswSwitchPoeDevicesHighPriority
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of stack power objects that are used to track the
+ stack power parameters of a switch."
+ ::= { cswStackWiseMIBGroups 5 }
+
+cswStackPowerPortStatusGroup OBJECT-GROUP
+ OBJECTS {
+ cswStackPowerPortOperStatus,
+ cswStackPowerPortNeighborMacAddress,
+ cswStackPowerPortNeighborSwitchNum,
+ cswStackPowerPortLinkStatus,
+ cswStackPowerPortOverCurrentThreshold,
+ cswStackPowerPortName
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects that are used for control and status of
+ stack power ports."
+ ::= { cswStackWiseMIBGroups 6 }
+
+cswStackPowerNotificationGroup NOTIFICATION-GROUP
+ NOTIFICATIONS {
+ cswStackPowerPortLinkStatusChanged,
+ cswStackPowerPortOperStatusChanged,
+ cswStackPowerVersionMismatch,
+ cswStackPowerInvalidTopology,
+ cscwStackPowerBudgetWarrning,
+ cswStackPowerInvalidInputCurrent,
+ cswStackPowerInvalidOutputCurrent,
+ cswStackPowerUnderBudget,
+ cswStackPowerUnbalancedPowerSupplies,
+ cswStackPowerInsufficientPower,
+ cswStackPowerPriorityConflict,
+ cswStackPowerUnderVoltage,
+ cswStackPowerGLS,
+ cswStackPowerILS,
+ cswStackPowerSRLS,
+ cswStackPowerSSLS
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of notifications that are triggered whenever there
+ is either a change in stack power object or an error is
+ encountered."
+ ::= { cswStackWiseMIBGroups 7 }
+
+cswStackPowerEnableNotificationGroup OBJECT-GROUP
+ OBJECTS { cswEnableIndividualStackNotifications }
+ STATUS current
+ DESCRIPTION
+ "This group contains the notification enable objects for this
+ MIB."
+ ::= { cswStackWiseMIBGroups 8 }
+
+cswNotificationGroupSup1 NOTIFICATION-GROUP
+ NOTIFICATIONS { cswStackMemberToBeReloadedForUpgrade }
+ STATUS current
+ DESCRIPTION
+ "Additional notification required for data stack."
+ ::= { cswStackWiseMIBGroups 9 }
+
+cswStackPowerAllocatedGroup OBJECT-GROUP
+ OBJECTS { cswSwitchPowerAllocated }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing the stack power allocation
+ information of a switch."
+ ::= { cswStackWiseMIBGroups 10 }
+
+cswStatusGroupRev2 OBJECT-GROUP
+ OBJECTS {
+ cswMaxSwitchNum,
+ cswMaxSwitchConfigPriority,
+ cswRingRedundant,
+ cswSwitchNumCurrent,
+ cswSwitchNumNextReload,
+ cswSwitchRole,
+ cswSwitchSwPriority,
+ cswSwitchHwPriority,
+ cswSwitchState,
+ cswSwitchMacAddress,
+ cswStackDomainNum,
+ cswStackType,
+ cswStackBandWidth
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects that are used for control and
+ status."
+ ::= { cswStackWiseMIBGroups 11 }
+
+cswDistrStackLinkStatusGroup OBJECT-GROUP
+ OBJECTS { cswDistrStackLinkBundleOperStatus }
+ STATUS current
+ DESCRIPTION
+ "A collection object(s) for control and status of the
+ distributed Stack Link."
+ ::= { cswStackWiseMIBGroups 12 }
+
+cswDistrStackPhyPortStatusGroup OBJECT-GROUP
+ OBJECTS {
+ cswDistrStackPhyPort,
+ cswDistrStackPhyPortOperStatus,
+ cswDistrStackPhyPortNbr,
+ cswDistrStackPhyPortNbrsw
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects for control and status of the
+ distributed stack port"
+ ::= { cswStackWiseMIBGroups 13 }
+
+END
+
+