summaryrefslogtreecommitdiff
path: root/MIBS/cisco/CISCO-CAT6K-CROSSBAR-MIB
diff options
context:
space:
mode:
Diffstat (limited to 'MIBS/cisco/CISCO-CAT6K-CROSSBAR-MIB')
-rw-r--r--MIBS/cisco/CISCO-CAT6K-CROSSBAR-MIB3028
1 files changed, 3028 insertions, 0 deletions
diff --git a/MIBS/cisco/CISCO-CAT6K-CROSSBAR-MIB b/MIBS/cisco/CISCO-CAT6K-CROSSBAR-MIB
new file mode 100644
index 0000000..4359a08
--- /dev/null
+++ b/MIBS/cisco/CISCO-CAT6K-CROSSBAR-MIB
@@ -0,0 +1,3028 @@
+-- *****************************************************************
+-- CISCO-CAT6K-CROSSBAR-MIB.my
+--
+-- Mar 2001, Padma Pullela
+-- Nov. 2002, Padma Pullela/Lilian Jiang
+-- March 2003, Padma Pullela
+-- June 2004, Padma Pullela
+--
+-- Copyright (c) 2001-2009, 2012-2013 by cisco Systems, Inc.
+-- All rights reserved.
+-- *****************************************************************
+
+CISCO-CAT6K-CROSSBAR-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ MODULE-IDENTITY,
+ OBJECT-TYPE,
+ Counter32,
+ Unsigned32,
+ Gauge32,
+ NOTIFICATION-TYPE
+ FROM SNMPv2-SMI
+ MODULE-COMPLIANCE,
+ OBJECT-GROUP,
+ NOTIFICATION-GROUP
+ FROM SNMPv2-CONF
+ TEXTUAL-CONVENTION,
+ TruthValue,
+ DisplayString,
+ DateAndTime,
+ TimeStamp
+ FROM SNMPv2-TC
+ entPhysicalName,
+ entPhysicalVendorType,
+ entPhysicalIndex,
+ entPhysicalDescr
+ FROM ENTITY-MIB
+ Percent
+ FROM CISCO-QOS-PIB-MIB
+ ciscoMgmt
+ FROM CISCO-SMI;
+
+
+ciscoCat6kCrossbarMIB MODULE-IDENTITY
+ LAST-UPDATED "201309160000Z"
+ ORGANIZATION "Cisco Systems, Inc."
+ CONTACT-INFO
+ "Cisco Systems
+ Customer Service
+ Postal: 170 W Tasman Drive
+ San Jose, CA 95134
+ USA
+ Tel: +1 800 553-NETS
+
+ E-mail: cs-cat6000@cisco.com"
+ DESCRIPTION
+ "The Catalyst 6000 Crossbar MIB provides instrumentation for
+ configuration and operation of the crossbar switching fabric
+ module, and additional functionalities for switching bus
+ and internal bus, etc."
+ REVISION "201309160000Z"
+ DESCRIPTION
+ "Added two new enumerations 'pfc4xxl' and 'pfc4lite'
+ in cc6kxbarSysCapPfcOperMode."
+ REVISION "201205310000Z"
+ DESCRIPTION
+ "Added following OBJECT-GROUP
+ - cc6kxbarStatisticsLbusDropGroup
+ Added new compliance
+ - cc6kxbarMIBComplianceVer8.
+ Updated the description for
+ - cc6kxbarStatisticsPeakTmInUtil
+ - cc6kxbarStatisticsPeakTmOutUtil."
+ REVISION "200902150000Z"
+ DESCRIPTION
+ "Added cc6kxbarErrRcvryPersLinkResGroup and
+ cc6kxbarErrRcvryChResyncGroup,
+ cc6kxbarTMSwBusUtilGroup,
+ cc6kxbarTMSwBusUtilNotifControlGroup,
+ cc6kxbarTMSwBusUtilNotifObjectGroup,
+ cc6kxbarTMSwBusUtilNotifGroup,
+ cc6kxbarTMChUtilGroup,
+ cc6kxbarTMChUtilNotifControlGroup,
+ cc6kxbarTMChUtilNotifObjectGroup,
+ cc6kxbarTMChUtilNotifGroup.
+
+ Added two new enumerations 'pfc4' and 'pfc4xl'
+ in cc6kxbarSysCapPfcOperMode.
+
+ Added DISPLAY-HINT in TEXTUAL-CONVENTION
+ of ModuleSlotNumber and FabricChannelNumber."
+ REVISION "200712180000Z"
+ DESCRIPTION
+ "Added cc6kxbarSysCapPfcOperModeGroup,
+ cc6kxbarSysCapSwitchResGroup, cc6kxbarChannelUtilGroup1,
+ cc6kxbarSwBusGroup1, cc6kxbarErrorGroup,
+ cc6kxbarErrRcvryThresholdGroup and
+ cc6kxbarErrRcvrySwitchoverGroup."
+ REVISION "200612190000Z"
+ DESCRIPTION
+ "Added cc6kxbarDcefOnlyModeAllowedGroup,
+ cc6kxbarForceBusModeGroup,
+ cc6kxbarFlowCtrlNotifCtrlGroup,
+ cc6kxbarFlowCtrlBusThreshGroup,
+ cc6kxbarFlowCtrlBusThrNotifGroup
+ and cc6kxbarBusOnlyModeOperGroup."
+ REVISION "200411190000Z"
+ DESCRIPTION
+ "Added cc6kxbarIntBusCRCErrGroup."
+ REVISION "200408110000Z"
+ DESCRIPTION
+ "Added cc6kxbarIntBusNotifControlGroup and
+ cc6kxbarIntBusCRCErrNotifGroup."
+ REVISION "200406110000Z"
+ DESCRIPTION
+ "Added cc6kxbarTruncatedModeOper Object and changed the
+ description of cc6kxbarTruncatedModeAllowed and
+ cc6kxbarMinFabricPresent."
+ REVISION "200309290000Z"
+ DESCRIPTION
+ "Changed the description of cc6kxbarTruncatedModeAllowed and
+ cc6kxbarMinFabricPresent. Removed default value for
+ cc6kxbarTruncatedModeAllowed."
+ REVISION "200304020000Z"
+ DESCRIPTION
+ "Changed the SYNTAX and description of cc6kxbarMinFabricPresent
+ and description of cc6kxbarTruncatedModeAllowed."
+ REVISION "200212050000Z"
+ DESCRIPTION
+ "Added cc6kxbarModuleChannelSpeed, cc6kxbarSwBusSwitchingStatus,
+ cc6kxbarSwBusFailureDuration, cc6kxbarSwBusNotifEnable
+ objects and cc6kxbarSwBusStallNotif notification."
+ REVISION "200106250000Z"
+ DESCRIPTION
+ "Initial version of this MIB module."
+ ::= { ciscoMgmt 217 }
+
+
+ciscoCat6kXbarMIBObjects OBJECT IDENTIFIER
+ ::= { ciscoCat6kCrossbarMIB 1 }
+
+cc6kxbarConfiguration OBJECT IDENTIFIER
+ ::= { ciscoCat6kXbarMIBObjects 1 }
+
+cc6kxbarStatus OBJECT IDENTIFIER
+ ::= { ciscoCat6kXbarMIBObjects 2 }
+
+cc6kxbarStatistics OBJECT IDENTIFIER
+ ::= { ciscoCat6kXbarMIBObjects 3 }
+
+cc6kxbarSwBusObjects OBJECT IDENTIFIER
+ ::= { ciscoCat6kXbarMIBObjects 4 }
+
+cc6kxbarIntBusObjects OBJECT IDENTIFIER
+ ::= { ciscoCat6kXbarMIBObjects 5 }
+
+cc6kxbarFlowCtrlObjects OBJECT IDENTIFIER
+ ::= { ciscoCat6kXbarMIBObjects 6 }
+
+cc6kxbarSystemCapacityObjects OBJECT IDENTIFIER
+ ::= { ciscoCat6kXbarMIBObjects 7 }
+
+cc6kxbarErrorRecoveryObjects OBJECT IDENTIFIER
+ ::= { ciscoCat6kXbarMIBObjects 8 }
+
+cc6kxbarTrafficMonitorObjects OBJECT IDENTIFIER
+ ::= { ciscoCat6kXbarMIBObjects 9 }
+
+cc6kxbarTrafficMonitorSwBusObjects OBJECT IDENTIFIER
+ ::= { cc6kxbarTrafficMonitorObjects 1 }
+
+cc6kxbarTrafficMonitorChObjects OBJECT IDENTIFIER
+ ::= { cc6kxbarTrafficMonitorObjects 2 }
+
+
+-- Textual Conventions
+
+ModuleSlotNumber ::= TEXTUAL-CONVENTION
+ DISPLAY-HINT "d"
+ STATUS current
+ DESCRIPTION
+ "Slot number of the module."
+ SYNTAX Unsigned32
+
+FabricChannelNumber ::= TEXTUAL-CONVENTION
+ DISPLAY-HINT "d"
+ STATUS current
+ DESCRIPTION
+ "Fabric channel number."
+ SYNTAX Unsigned32
+
+ChannelStatus ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "Status of the Channel."
+ SYNTAX INTEGER {
+ ok(1),
+ syncError(2),
+ heartbeatError(3),
+ crcError(4),
+ bufferError(5),
+ timeoutError(6),
+ unused(7)
+ }
+
+-- Configuration objects
+
+cc6kxbarFallbackMode OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "cc6kxbarFallbackMode controls system fallback to bus-mode
+ after loss of switching fabric module.
+ 'true' - When the last fabric card is removed
+ system will adjust the supervisor and
+ line cards switching mode automatically without
+ resetting the system. With this feature enabled,
+ the switch might lose traffic while it's
+ changing the switching mode.
+ 'false' - All the ports in the system will be
+ disabled when the last fabric card is removed."
+ DEFVAL { true }
+ ::= { cc6kxbarConfiguration 1 }
+
+cc6kxbarBusOnlyModeAllowed OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Indicates whether bus mode is administratively enabled on
+ the device or not."
+ ::= { cc6kxbarConfiguration 2 }
+
+cc6kxbarTruncatedModeAllowed OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Indicates whether truncated mode is
+ administratively enabled on the device or not."
+ ::= { cc6kxbarConfiguration 3 }
+
+cc6kxbarMinFabricPresent OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object indicates the minimum number
+ of switching fabric capable modules to be present in the
+ system, for any switching fabric capable module to be in
+ 'crossbarmode' indicated by cc6kxbarModuleModeSwitchingMode,
+ when cc6kxbarTruncatedModeOper is 'false'."
+ ::= { cc6kxbarConfiguration 4 }
+
+cc6kxbarLcdBannerTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Cc6kxbarLcdBannerEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "cc6kxbarLcdBannerTable configures the Lcd banner of the
+ fabric module."
+ ::= { cc6kxbarConfiguration 5 }
+
+cc6kxbarLcdBannerEntry OBJECT-TYPE
+ SYNTAX Cc6kxbarLcdBannerEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in cc6kxbarLcdBannerTable.
+ Entries are created by the agent based on the
+ size of the lcd banner."
+ INDEX { cc6kxbarLcdBannerIndex }
+ ::= { cc6kxbarLcdBannerTable 1 }
+
+Cc6kxbarLcdBannerEntry ::= SEQUENCE {
+ cc6kxbarLcdBannerIndex Unsigned32,
+ cc6kxbarLcdBannerBanner DisplayString,
+ cc6kxbarLcdBannerMaxSize Unsigned32
+}
+
+cc6kxbarLcdBannerIndex OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Object which specifies a unique entry in the
+ table."
+ ::= { cc6kxbarLcdBannerEntry 1 }
+
+cc6kxbarLcdBannerBanner OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Message that would be displayed on the fabric card LCD.
+ The size of cc6kxbarLcdBannerBanner should be less than
+ or equal to the cc6kxbarLcdBannerMaxSize value."
+ ::= { cc6kxbarLcdBannerEntry 2 }
+
+cc6kxbarLcdBannerMaxSize OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Maximum size of the associated cc6kxbarLcdBannerBanner
+ object."
+ ::= { cc6kxbarLcdBannerEntry 3 }
+
+
+
+cc6kxbarTruncatedModeOper OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates if the truncated mode is
+ operationally enabled on the device or not.
+ 'true' - With the fabric module present in the system,
+ cc6kxbarModuleModeSwitchingMode will be
+ 'crossbarmode' for all the fabric capable
+ modules.
+ 'false'- With the cc6kxbarMinFabricPresent fabric capable
+ modules and the fabric module present in the system,
+ cc6kxbarModuleModeSwitchingMode
+ will be 'crossbarmode' for fabric capable modules."
+ ::= { cc6kxbarConfiguration 6 }
+
+cc6kxbarDcefOnlyModeAllowed OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Indicates whether the dcef mode is enabled on the standby
+ supervisor or not.
+ 'true' - Setting cc6kxbarDcefOnlyModeAllowed to 'true'
+ makes the cc6kxbarModuleModeSwitchingMode of
+ all the active modules to 'dcefmode'.
+ With the active fabric module present in the system,
+ with the switch being in stateful switchover mode,
+ with all the cards that has no distributed Cisco
+ Express forwarding switching support being
+ powered down and on some platforms with standby
+ supervisor ports being shutdown, changing
+ cc6kxbarDcefOnlyModeAllowed to 'true' will make the
+ standby supervisor module reloaded and booted up
+ as distributed forwarding module.
+ 'false'- Setting cc6kxbarDcefOnlyModeAllowed to 'false'
+ makes the cc6kxbarModuleModeSwitchingMode of the
+ standby supervisor module to the default value.
+ Changing cc6kxbarDcefOnlyModeAllowed to 'false'
+ will make the standby supervisor reloaded and booted
+ up with the default cc6kxbarModuleModeSwitchingMode."
+ ::= { cc6kxbarConfiguration 7 }
+
+cc6kxbarForceBusMode OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Indicates whether some affected modules are forced to be in
+ 'busmode' or not.
+ 'true' - Setting cc6kxbarForceBusMode to 'true' makes the
+ cc6kxbarModuleModeSwitchingMode of all
+ the affected modules to 'busmode'. Changing the
+ cc6kxbarForceBusMode to 'true' will make all the
+ affected modules reloaded and booted up as
+ non fabric capable modules.
+ 'false'- Setting cc6kxbarForceBusMode to 'false' makes the
+ cc6kxbarModuleModeSwitchingMode of all the affected
+ modules to the default value. Changing
+ cc6kxbarForceBusMode to 'false' will make all the
+ affected modules reloaded and booted up with the
+ default cc6kxbarModuleModeSwitchingMode."
+ ::= { cc6kxbarConfiguration 8 }
+
+cc6kxbarBusOnlyModeOper OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates if the bus mode is operationally enabled on the
+ device or not.
+
+ 'true' - Modules are allowed to run in 'busmode'.
+ 'false' - None of the modules are allowed to run in 'busmode'
+ i.e., All the non-fabric capable modules will
+ be powered off. Absence of fabric module results
+ in all the fabric capable modules being powered
+ off."
+ ::= { cc6kxbarConfiguration 9 }
+
+-- Status objects
+
+cc6kxbarFabricActiveSlot OBJECT-TYPE
+ SYNTAX ModuleSlotNumber
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "cc6kxbarFabricActiveSlot indicates the slot number of the
+ active switching fabric module. A value of zero indicates
+ that the active switching fabric module is either powered
+ down or not present in the chassis."
+ ::= { cc6kxbarStatus 1 }
+
+cc6kxbarFabricBackupSlot OBJECT-TYPE
+ SYNTAX ModuleSlotNumber
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "cc6kxbarFabricBackupSlot indicates the slot number of the
+ backup switching fabric module. A value of zero indicates
+ that the backup switching fabric module is either powered
+ down or not present in the chassis."
+ ::= { cc6kxbarStatus 2 }
+
+cc6kxbarModuleModeTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Cc6kxbarModuleModeEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "cc6kxbarModuleModeTable indicates the switching mode of each
+ module in the system."
+ ::= { cc6kxbarStatus 3 }
+
+cc6kxbarModuleModeEntry OBJECT-TYPE
+ SYNTAX Cc6kxbarModuleModeEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in cc6kxbarModuleModeTable. The agent creates
+ an entry when a non switching fabric module
+ is inserted in the chassis.
+ The agent destroys an entry when a non switching fabric
+ module is power down or reset or removed from the chassis."
+ INDEX { cc6kxbarModuleModeModule }
+ ::= { cc6kxbarModuleModeTable 1 }
+
+Cc6kxbarModuleModeEntry ::= SEQUENCE {
+ cc6kxbarModuleModeModule ModuleSlotNumber,
+ cc6kxbarModuleModeSwitchingMode INTEGER
+}
+
+cc6kxbarModuleModeModule OBJECT-TYPE
+ SYNTAX ModuleSlotNumber
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The module slot number."
+ ::= { cc6kxbarModuleModeEntry 1 }
+
+cc6kxbarModuleModeSwitchingMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ busmode(1),
+ crossbarmode(2),
+ dcefmode(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "cc6kxbarModuleModeSwitchingMode indicates switching mode
+ of the cc6kxbarModuleModeModule.
+ 'busmode' - Modules in this mode don't use fabric.
+ Backplane is used for both lookup and data
+ forwarding.
+ 'crossbarmode' - Modules in this mode use backplane
+ for forwarding decision and fabric for data
+ forwarding
+ 'dcefmode' - Modules in this mode use fabric for data
+ forwarding and local forwarding is enabled."
+ ::= { cc6kxbarModuleModeEntry 2 }
+
+
+
+cc6kxbarModuleChannelTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Cc6kxbarModuleChannelEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "cc6kxbarModuleChannelTable shows the operational status
+ of fabric channels. This table will be instantiated only when
+ cc6kxbarFabricActiveSlot has a valid value other than zero."
+ ::= { cc6kxbarStatus 4 }
+
+cc6kxbarModuleChannelEntry OBJECT-TYPE
+ SYNTAX Cc6kxbarModuleChannelEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in cc6kxbarModuleChannelTable."
+ INDEX {
+ cc6kxbarModuleChannelModule,
+ cc6kxbarModuleChannelChannel
+ }
+ ::= { cc6kxbarModuleChannelTable 1 }
+
+Cc6kxbarModuleChannelEntry ::= SEQUENCE {
+ cc6kxbarModuleChannelModule ModuleSlotNumber,
+ cc6kxbarModuleChannelChannel FabricChannelNumber,
+ cc6kxbarModuleChannelModStatus ChannelStatus,
+ cc6kxbarModuleChannelFabStatus ChannelStatus,
+ cc6kxbarModuleChannelSpeed Gauge32
+}
+
+cc6kxbarModuleChannelModule OBJECT-TYPE
+ SYNTAX ModuleSlotNumber
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The module slot number."
+ ::= { cc6kxbarModuleChannelEntry 1 }
+
+cc6kxbarModuleChannelChannel OBJECT-TYPE
+ SYNTAX FabricChannelNumber
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Fabric channel number of the cc6kxbarModuleChannelModule."
+ ::= { cc6kxbarModuleChannelEntry 2 }
+
+cc6kxbarModuleChannelModStatus OBJECT-TYPE
+ SYNTAX ChannelStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The status of the fabric channel at the
+ cc6kxbarModuleChannelModule."
+ ::= { cc6kxbarModuleChannelEntry 3 }
+
+cc6kxbarModuleChannelFabStatus OBJECT-TYPE
+ SYNTAX ChannelStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The status of the fabric channel at the
+ cc6kxbarFabricActiveSlot."
+ ::= { cc6kxbarModuleChannelEntry 4 }
+
+cc6kxbarModuleChannelSpeed OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The speed in mega bits per second of the
+ cc6kxbarModuleChannelChannel for cc6kxbarModuleChannelModule."
+ ::= { cc6kxbarModuleChannelEntry 5 }
+
+
+-- Statistics Objects
+
+cc6kxbarStatisticsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Cc6kxbarStatisticsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "cc6kxbarStatisticsTable gives the
+ fabric channel counters and utilization
+ information. This table will be instantiated when
+ cc6kxbarFabricActiveSlot has a valid value other than
+ zero."
+ ::= { cc6kxbarStatistics 1 }
+
+cc6kxbarStatisticsEntry OBJECT-TYPE
+ SYNTAX Cc6kxbarStatisticsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in cc6kxbarStatisticsTable."
+ INDEX {
+ cc6kxbarStatisticsModule,
+ cc6kxbarStatisticsChannel
+ }
+ ::= { cc6kxbarStatisticsTable 1 }
+
+Cc6kxbarStatisticsEntry ::= SEQUENCE {
+ cc6kxbarStatisticsModule ModuleSlotNumber,
+ cc6kxbarStatisticsChannel FabricChannelNumber,
+ cc6kxbarStatisticsInErrors Counter32,
+ cc6kxbarStatisticsOutErrors Counter32,
+ cc6kxbarStatisticsOutDropped Counter32,
+ cc6kxbarStatisticsInUtil Percent,
+ cc6kxbarStatisticsOutUtil Percent,
+ cc6kxbarStatisticsPeakInUtil Percent,
+ cc6kxbarStatisticsPeakTmInUtil DateAndTime,
+ cc6kxbarStatisticsPeakOutUtil Percent,
+ cc6kxbarStatisticsPeakTmOutUtil DateAndTime,
+ cc6kxbarStatisticsLbusDrops Counter32
+}
+
+cc6kxbarStatisticsModule OBJECT-TYPE
+ SYNTAX ModuleSlotNumber
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The module slot number."
+ ::= { cc6kxbarStatisticsEntry 1 }
+
+cc6kxbarStatisticsChannel OBJECT-TYPE
+ SYNTAX FabricChannelNumber
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Fabric channel number associated with the
+ cc6kxbarStatisticsModule."
+ ::= { cc6kxbarStatisticsEntry 2 }
+
+cc6kxbarStatisticsInErrors OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of error packets received on
+ cc6kxbarStatisticsChannel for cc6kxbarStatisticsModule
+ since this entry was last initialized."
+ ::= { cc6kxbarStatisticsEntry 3 }
+
+cc6kxbarStatisticsOutErrors OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of error packets transmitted on
+ cc6kxbarStatisticsModule through the
+ cc6kxbarStatisticsChannel since this entry was
+ last initialized."
+ ::= { cc6kxbarStatisticsEntry 4 }
+
+cc6kxbarStatisticsOutDropped OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of dropped packets transmitted on the
+ cc6kxbarStatisticsChannel for cc6kxbarStatisticsModule
+ since this entry was last initialized."
+ ::= { cc6kxbarStatisticsEntry 5 }
+
+cc6kxbarStatisticsInUtil OBJECT-TYPE
+ SYNTAX Percent
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Input utilization of the cc6kxbarStatisticsChannel for
+ cc6kxbarStatisticsModule."
+ ::= { cc6kxbarStatisticsEntry 6 }
+
+cc6kxbarStatisticsOutUtil OBJECT-TYPE
+ SYNTAX Percent
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Output utilization of the cc6kxbarStatisticsChannel for
+ cc6kxbarStatisticsModule."
+ ::= { cc6kxbarStatisticsEntry 7 }
+
+cc6kxbarStatisticsPeakInUtil OBJECT-TYPE
+ SYNTAX Percent
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the peak value of cc6kxbarStatisticsInUtil of the
+ cc6kxbarStatisticsChannel for cc6kxbarStatisticsModule."
+ ::= { cc6kxbarStatisticsEntry 8 }
+
+cc6kxbarStatisticsPeakTmInUtil OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the time of most recent change in the corresponding
+ instance value of cc6kxbarStatisticsPeakInUtil.
+
+ This object contains value 0x0000010100000000 when the
+ corresponding instance value of cc6kxbarStatisticsPeakInUtil
+ is '0'."
+ ::= { cc6kxbarStatisticsEntry 9 }
+
+cc6kxbarStatisticsPeakOutUtil OBJECT-TYPE
+ SYNTAX Percent
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the peak value of cc6kxbarStatisticsOutUtil of the
+ cc6kxbarStatisticsChannel for cc6kxbarStatisticsModule."
+ ::= { cc6kxbarStatisticsEntry 10 }
+
+cc6kxbarStatisticsPeakTmOutUtil OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the time of most recent change in the corresponding
+ instance value of cc6kxbarStatisticsPeakOutUtil.
+
+ This object contains value 0x0000010100000000 when the
+ corresponding instance value of cc6kxbarStatisticsPeakOutUtil
+ is '0'."
+ ::= { cc6kxbarStatisticsEntry 11 }
+
+cc6kxbarStatisticsLbusDrops OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object indicates the number of packets that have been
+ deterministically dropped due to the threshold on the local
+ bus FIFO, errors and exception conditions."
+ ::= { cc6kxbarStatisticsEntry 12 }
+
+
+
+cc6kxbarErrorTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Cc6kxbarErrorEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "cc6kxbarErrorTable provides the fabric channel error
+ information. This table will be instantiated only when
+ cc6kxbarFabricActiveSlot has a valid value other than zero."
+ ::= { cc6kxbarStatistics 2 }
+
+cc6kxbarErrorEntry OBJECT-TYPE
+ SYNTAX Cc6kxbarErrorEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in cc6kxbarErrorTable for a specific fabric channel
+ on a specific module."
+ INDEX {
+ cc6kxbarErrorModule,
+ cc6kxbarErrorChannel
+ }
+ ::= { cc6kxbarErrorTable 1 }
+
+Cc6kxbarErrorEntry ::= SEQUENCE {
+ cc6kxbarErrorModule ModuleSlotNumber,
+ cc6kxbarErrorChannel FabricChannelNumber,
+ cc6kxbarErrorModuleCrc Gauge32,
+ cc6kxbarErrorModuleHbeat Gauge32,
+ cc6kxbarErrorModuleSync Gauge32,
+ cc6kxbarErrorModuleDDRSync Gauge32,
+ cc6kxbarErrorChannelSync Gauge32,
+ cc6kxbarErrorChannelBuffer Gauge32,
+ cc6kxbarErrorChannelTimeout Gauge32
+}
+
+cc6kxbarErrorModule OBJECT-TYPE
+ SYNTAX ModuleSlotNumber
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The module slot number."
+ ::= { cc6kxbarErrorEntry 1 }
+
+cc6kxbarErrorChannel OBJECT-TYPE
+ SYNTAX FabricChannelNumber
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Fabric channel number associated with the
+ cc6kxbarErrorModule."
+ ::= { cc6kxbarErrorEntry 2 }
+
+cc6kxbarErrorModuleCrc OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the total number of CRC error packets for the
+ cc6kxbarErrorChannel of the cc6kxbarErrorModule."
+ ::= { cc6kxbarErrorEntry 3 }
+
+cc6kxbarErrorModuleHbeat OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the total number of heartbeat misses detected
+ for the cc6kxbarErrorChannel of the cc6kxbarErrorModule."
+ ::= { cc6kxbarErrorEntry 4 }
+
+cc6kxbarErrorModuleSync OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the total number of times cc6kxbarErrorModule could
+ not sync to the active switching fabric module."
+ ::= { cc6kxbarErrorEntry 5 }
+
+cc6kxbarErrorModuleDDRSync OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the total number of DDR(Double Data Rate) channel
+ sync errors for the cc6kxbarErrorChannel of the
+ cc6kxbarErrorModule."
+ ::= { cc6kxbarErrorEntry 6 }
+
+cc6kxbarErrorChannelSync OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the total number of sync errors received at
+ cc6kxbarErrorChannel."
+ ::= { cc6kxbarErrorEntry 7 }
+
+cc6kxbarErrorChannelBuffer OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the total number of times the memory buffer for
+ cc6kxbarErrorChannel of the cc6kxbarErrorModule is full."
+ ::= { cc6kxbarErrorEntry 8 }
+
+cc6kxbarErrorChannelTimeout OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the total number of timeouts for input from
+ the cc6kxbarErrorChannel of the cc6kxbarErrorModule."
+ ::= { cc6kxbarErrorEntry 9 }
+
+
+
+-- Switching Bus Objects
+
+cc6kxbarSwBusSwitchingStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal(1),
+ stalled(2),
+ isolated(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the current switching status of the
+ switching bus on the system.
+
+ normal -- the switching bus is under normal
+ packet switching operation.
+
+ stalled -- the switching bus has stopped packet
+ switching but is still attached to
+ the system, i.e., the switching bus
+ is stalled.
+
+ isolated -- the switching bus has stopped packet
+ switching and is detached from
+ the system, i.e., the switching bus
+ is isolated.
+
+ The object is only instantiated on systems which
+ support switching bus switching detection feature."
+ ::= { cc6kxbarSwBusObjects 1 }
+
+cc6kxbarSwBusFailureDuration OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "seconds"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the failure duration of the switching
+ bus since the switching bus has transitioned
+ out of the normal(1) state as monitored by
+ cc6kxbarSwBusSwitchingStatus. If the object
+ value of cc6kxbarSwBusSwitchingStatus is
+ normal(1), then the object value of
+ cc6kxbarSwBusFailureDuration should be zero.
+
+ The object is only instantiated on systems which
+ support switching bus switching detection feature."
+ ::= { cc6kxbarSwBusObjects 2 }
+
+cc6kxbarSwBusNotifEnable OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Indicates whether or not the notification
+ cc6kxbarSwBusStatusChangeNotif should be generated
+ when there is change in the switching status of the
+ switching bus as monitored by
+ cc6kxbarSwBusSwitchingStatus.
+
+ The object is only instantiated on systems which
+ support switching bus switching detection feature."
+ ::= { cc6kxbarSwBusObjects 3 }
+
+cc6kxbarSwBusUtilization OBJECT-TYPE
+ SYNTAX Percent
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the percentage of bandwidth utilization
+ of the switching bus."
+ ::= { cc6kxbarSwBusObjects 4 }
+
+cc6kxbarSwBusPeakUtilization OBJECT-TYPE
+ SYNTAX Percent
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the peak percentage value of bandwidth
+ utilization of the switching bus since the system
+ started."
+ ::= { cc6kxbarSwBusObjects 5 }
+
+cc6kxbarSwBusPeakTimeUtil OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the time at which the peak percentage value
+ of bandwidth utilization of the switching bus value
+ occurred."
+ ::= { cc6kxbarSwBusObjects 6 }
+
+-- Internal Bus Objects
+
+cc6kxbarIntBusNotifEnable OBJECT-TYPE
+ SYNTAX BITS {
+ intBusCRCErrExcd(0),
+ intBusCRCErrRcvrd(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Indicates whether the generation of a specified
+ notification for internal bus is enabled or not.
+ If a bit corresponding to a notification is set to
+ 1, then that notification can be generated.
+
+ intBusCRCErrExcd -- the cc6kxbarIntBusCRCErrExcdNotif
+ notification.
+
+ intBusCRCErrRcvrd -- the cc6kxbarIntBusCRCErrRcvrdNotif
+ notification."
+ ::= { cc6kxbarIntBusObjects 1 }
+
+cc6kxbarIntBusCRCErrTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Cc6kxbarIntBusCRCErrEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table containing internal bus CRC error information
+ on a list of physical entities (such as modules)."
+ ::= { cc6kxbarIntBusObjects 2 }
+
+cc6kxbarIntBusCRCErrEntry OBJECT-TYPE
+ SYNTAX Cc6kxbarIntBusCRCErrEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing internal bus CRC error information
+ on a physical entity (such as a module)."
+ INDEX { entPhysicalIndex }
+ ::= { cc6kxbarIntBusCRCErrTable 1 }
+
+Cc6kxbarIntBusCRCErrEntry ::= SEQUENCE {
+ cc6kxbarIntBusCRCErrExcdStatus TruthValue,
+ cc6kxbarIntBusCRCErrExcdCount Unsigned32
+}
+
+cc6kxbarIntBusCRCErrExcdStatus OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates whether the internal bus CRC error
+ on a physical entity is currently exceeding the fatal
+ threshold or not."
+ ::= { cc6kxbarIntBusCRCErrEntry 1 }
+
+cc6kxbarIntBusCRCErrExcdCount OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the number of times the internal bus CRC
+ error on a physical entity has exceeded the fatal
+ threshold."
+ ::= { cc6kxbarIntBusCRCErrEntry 2 }
+
+
+
+-- Flow Control Objects
+
+cc6kxbarFlowCtrlNotifEnable OBJECT-TYPE
+ SYNTAX BITS {
+ busThreshExcd(0)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Specifies whether the generation of a specified
+ notification for flow control feature is enabled or
+ not. If a bit corresponding to a notification is set
+ to one, then that notification can be generated.
+
+ busThreshExcd -- the cc6kxbarFlowCtrlBusThrExcdNotif
+ notification."
+ ::= { cc6kxbarFlowCtrlObjects 1 }
+
+cc6kxbarFlowCtrlBusFIFOThrMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ off(1),
+ on(2),
+ auto(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Specifies the mode configuration of the system bus
+ flow control FIFO threshold.
+
+ off -- the flow control FIFO threshold is set to the
+ original value defined by the system.
+
+ on -- the flow control FIFO threshold is set to the
+ lower value defined by the system.
+
+ auto -- the system starts monitoring the system bus
+ flow control FIFO threshold and will change the
+ flow control FIFO threshold from the original
+ value to the lower value when the system detects
+ the first occurrence of the threshold exceeding
+ on a physical entity (such as a module) over
+ the system allowed limit."
+ ::= { cc6kxbarFlowCtrlObjects 2 }
+
+cc6kxbarFlowCtrlBusFIFOThrValue OBJECT-TYPE
+ SYNTAX INTEGER {
+ original(1),
+ lower(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the current value of the system bus flow
+ control FIFO threshold, whether it is the original
+ value or the lower value."
+ ::= { cc6kxbarFlowCtrlObjects 3 }
+
+cc6kxbarFlowCtrlBusFIFOTransTime OBJECT-TYPE
+ SYNTAX TimeStamp
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the value of sysUpTime at the time
+ that the system bus flow control FIFO threshold
+ is transitioned to lower value when the object value
+ of cc6kxbarFlowCtrlBusFIFOThrValue is 'lower'. This
+ object will take on the value of zero when the object
+ value of cc6kxbarFlowCtrlBusFIFOThrValue is
+ 'original'."
+ ::= { cc6kxbarFlowCtrlObjects 4 }
+
+-- System Capacity Objects
+
+cc6kxbarSysCapPfcOperMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(1),
+ pfc3a(2),
+ pfc3b(3),
+ pfc3bxl(4),
+ pfc3cst1(5),
+ pfc3cxlst1(6),
+ pfc3c(7),
+ pfc3cxl(8),
+ pfc4(9),
+ pfc4xl(10),
+ pfc4xxl(11),
+ pfc4lite(12)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the operating mode of the policy feature
+ card (PFC).
+
+ unknown -- unknown.
+
+ pfc3a -- Policy feature card 3A.
+
+ pfc3b -- Policy feature card 3B.
+
+ pfc3bxl -- Policy feature card 3B XL.
+
+ pfc3cst1 -- Policy feature card 3C ST1.
+
+ pfc3cxlst1 -- Policy feature card 3C XL ST1.
+
+ pfc3c -- Policy feature card 3C.
+
+ pfc3cxl -- Policy feature card 3C XL.
+
+ pfc4 -- Policy feature card 4.
+
+ pfc4xl -- Policy feature card 4 XL.
+
+ pfc4xxl -- Policy feature card 4 XXL.
+
+ pfc4lite -- Policy feature card 4 Lite."
+ ::= { cc6kxbarSystemCapacityObjects 1 }
+
+cc6kxbarSysCapSwitchResTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Cc6kxbarSysCapSwitchResEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A cc6kxbarSysCapSwitchResTable entry lists
+ the capacity information of the switching
+ resources for ENTITY-MIB entPhysicalTable entries
+ of manageable components with type entPhysicalClass
+ module(9)."
+ ::= { cc6kxbarSystemCapacityObjects 2 }
+
+cc6kxbarSysCapSwitchResEntry OBJECT-TYPE
+ SYNTAX Cc6kxbarSysCapSwitchResEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A cc6kxbarSysCapSwitchResEntry entry lists
+ the capacity information of the switching
+ resources for ENTITY-MIB entPhysicalTable entries
+ of manageable components with type entPhysicalClass
+ module(9).
+
+ Entries are created by the agent at the system power-up
+ or module insertion.
+
+ Entries are deleted by the agent upon module removal."
+ INDEX { entPhysicalIndex }
+ ::= { cc6kxbarSysCapSwitchResTable 1 }
+
+Cc6kxbarSysCapSwitchResEntry ::= SEQUENCE {
+ cc6kxbarSysCapSwitchResSeries INTEGER,
+ cc6kxbarSysCapSwitchResCefMode INTEGER
+}
+
+cc6kxbarSysCapSwitchResSeries OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(1),
+ supervisor(2),
+ classic(3),
+ fabric(4),
+ dcef720(5),
+ cef720(6),
+ dcef256(7),
+ cef256(8)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the module series for traffic forwarding options.
+
+ unknown -- unknown.
+
+ supervisor -- supervisor module.
+
+ classic -- classic module.
+
+ fabric -- fabric module.
+
+ dcef720 -- dCEF720 module.
+
+ cef720 -- CEF720 module.
+
+ dcef256 -- dCEF256 module.
+
+ cef256 -- CEF256 module."
+ ::= { cc6kxbarSysCapSwitchResEntry 1 }
+
+cc6kxbarSysCapSwitchResCefMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ notApplicable(1),
+ dcef(2),
+ cef(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the Cisco Express Forwarding (CEF) mode of
+ the module.
+
+ notApplicable -- not applicable for this module.
+
+ dcef -- distributed CEF.
+
+ cef -- CEF."
+ ::= { cc6kxbarSysCapSwitchResEntry 2 }
+
+
+
+-- Fabric Error Recovery Objects
+
+cc6kxbarErrRcvryThreshLink OBJECT-TYPE
+ SYNTAX Unsigned32 (1..4294967295)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Specifies the threshold on fabric link errors occurring
+ in a channel for the fabric error recovery feature."
+ ::= { cc6kxbarErrorRecoveryObjects 1 }
+
+cc6kxbarErrRcvryThreshPersLink OBJECT-TYPE
+ SYNTAX Unsigned32 (1..4294967295)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Specifies the threshold on persistent fabric link errors
+ occurring in a channel for the fabric error recovery feature."
+ ::= { cc6kxbarErrorRecoveryObjects 2 }
+
+cc6kxbarErrRcvrySwitchoverEnable OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Specifies whether the switchover to the standby fabric module
+ is enabled or not on the detection of excessive fabric link
+ errors occurring in a channel for the fabric error recovery
+ feature."
+ ::= { cc6kxbarErrorRecoveryObjects 3 }
+
+cc6kxbarErrRcvryPersLinkResync OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Specifies whether the system will resync the channel or not
+ on the detection of excessive persistent fabric link errors
+ in a channel for the fabric error recovery feature."
+ ::= { cc6kxbarErrorRecoveryObjects 4 }
+
+cc6kxbarErrRcvryChResyncCount OBJECT-TYPE
+ SYNTAX Unsigned32 (1..4294967295)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Specifies the consecutive number of times of
+ channel resync within the time interval as specified
+ by cc6kxbarErrRcvryChResyncInterval, over which
+ the channel resync is considered as failure
+ for the fabric error recovery feature."
+ ::= { cc6kxbarErrorRecoveryObjects 5 }
+
+cc6kxbarErrRcvryChResyncInterval OBJECT-TYPE
+ SYNTAX Unsigned32 (1..4294967295)
+ UNITS "milliseconds"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Specifies the time interval for the consecutive
+ counting of channel resync for the fabric error
+ recovery feature."
+ ::= { cc6kxbarErrorRecoveryObjects 6 }
+
+-- Traffic Monitor Objects
+
+cc6kxbarTMSwBusUtilEnable OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Specifies whether the traffic monitor feature is
+ enabled on the switching bus or not."
+ ::= { cc6kxbarTrafficMonitorSwBusObjects 1 }
+
+cc6kxbarTMSwBusUtilInterval OBJECT-TYPE
+ SYNTAX Unsigned32 (1..4294967295)
+ UNITS "seconds"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Specifies the interval at the end of which
+ the switching bus traffic utilization is compared
+ against cc6kxbarTMSwBusUtilThreshold."
+ ::= { cc6kxbarTrafficMonitorSwBusObjects 2 }
+
+cc6kxbarTMSwBusUtilThreshold OBJECT-TYPE
+ SYNTAX Percent
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Specifies the threshold of the switching bus
+ traffic utilization."
+ ::= { cc6kxbarTrafficMonitorSwBusObjects 3 }
+
+cc6kxbarTMSwBusUtilLogCount OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the number of times the following
+ events are logged for the switching bus:
+
+ 1. the switching bus traffic utilization has
+ risen above the configured threshold (as
+ specified by cc6kxbarTMSwBusUtilThreshold),
+ or has kept staying above the configured
+ threshold at a logging interval (as specified
+ by cc6kxbarTMSwBusUtilLogInterval).
+
+ 2. the switching bus traffic utilization
+ has fallen below the configured threshold."
+ ::= { cc6kxbarTrafficMonitorSwBusObjects 4 }
+
+cc6kxbarTMSwBusUtilLastLogTime OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the last logging time of the
+ events as counted in cc6kxbarTMSwBusUtilLogCount.
+
+ This object will contain 0-1-1,00:00:00.0 when
+ the value of cc6kxbarTMSwBusUtilLogCount is zero."
+ ::= { cc6kxbarTrafficMonitorSwBusObjects 5 }
+
+cc6kxbarTMSwBusUtilLogInterval OBJECT-TYPE
+ SYNTAX Unsigned32 (1..4294967295)
+ UNITS "seconds"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Specifies the logging interval if the switching
+ bus traffic utilization keeps staying above the
+ cc6kxbarTMSwBusUtilThreshold."
+ ::= { cc6kxbarTrafficMonitorSwBusObjects 6 }
+
+cc6kxbarTMSwBusUtilUtilization OBJECT-TYPE
+ SYNTAX Percent
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "The switching bus traffic utilization included
+ in the notification currently being sent."
+ ::= { cc6kxbarTrafficMonitorSwBusObjects 7 }
+
+cc6kxbarTMSwBusUtilNotifEnable OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Specifies whether the generation of
+ c6kxbarTMSwBusUtilAboveNotif and
+ c6kxbarTMSwBusUtilBelowNotif notifications
+ is enabled or not.
+
+ When this object is 'true', the generation of
+ cc6kxbarTMSwBusUtilAboveNotif and
+ c6kxbarTMSwBusUtilBelowNotif notifications is
+ enabled. When this object is 'false', the
+ generation of cc6kxbarTMSwBusUtilAboveNotif and
+ c6kxbarTMSwBusUtilBelowNotif notifications
+ is disabled."
+ ::= { cc6kxbarTrafficMonitorSwBusObjects 8 }
+
+cc6kxbarTMChUtilTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Cc6kxbarTMChUtilEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "cc6kxbarTrafficMntrChUtilTable provides the
+ information on the traffic utilization of each
+ fabric channel associated with each module slot
+ for a given traffic direction in the chassis."
+ ::= { cc6kxbarTrafficMonitorChObjects 1 }
+
+cc6kxbarTMChUtilEntry OBJECT-TYPE
+ SYNTAX Cc6kxbarTMChUtilEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in cc6kxbarTMChUtilTable. Each traffic
+ direction for each fabric channel associated with
+ each module slot in the chassis will have an
+ entry in this table."
+ INDEX {
+ cc6kxbarTMChUtilModule,
+ cc6kxbarTMChUtilChannel,
+ cc6kxbarTMChUtilDirection
+ }
+ ::= { cc6kxbarTMChUtilTable 1 }
+
+Cc6kxbarTMChUtilEntry ::= SEQUENCE {
+ cc6kxbarTMChUtilModule ModuleSlotNumber,
+ cc6kxbarTMChUtilChannel FabricChannelNumber,
+ cc6kxbarTMChUtilDirection INTEGER,
+ cc6kxbarTMChUtilEnable TruthValue,
+ cc6kxbarTMChUtilInterval Unsigned32,
+ cc6kxbarTMChUtilThreshold Percent,
+ cc6kxbarTMChUtilLogCount Counter32,
+ cc6kxbarTMChUtilLastLogTime DateAndTime
+}
+
+cc6kxbarTMChUtilModule OBJECT-TYPE
+ SYNTAX ModuleSlotNumber
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Indicates the module slot number in the chassis."
+ ::= { cc6kxbarTMChUtilEntry 1 }
+
+cc6kxbarTMChUtilChannel OBJECT-TYPE
+ SYNTAX FabricChannelNumber
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Indicates the fabric channel number associated with
+ the corresponding cc6kxbarTMChUtilModule."
+ ::= { cc6kxbarTMChUtilEntry 2 }
+
+cc6kxbarTMChUtilDirection OBJECT-TYPE
+ SYNTAX INTEGER {
+ ingress(1),
+ egress(2)
+ }
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Indicates the direction of traffic to be monitored."
+ ::= { cc6kxbarTMChUtilEntry 3 }
+
+cc6kxbarTMChUtilEnable OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Specifies whether the traffic monitor feature is
+ enabled on a fabric channel for a given traffic
+ direction or not."
+ ::= { cc6kxbarTMChUtilEntry 4 }
+
+cc6kxbarTMChUtilInterval OBJECT-TYPE
+ SYNTAX Unsigned32 (1..4294967295)
+ UNITS "seconds"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Specifies the interval at the end of which the
+ traffic utilization on a fabric channel for a
+ given traffic direction is compared against
+ its corresponding cc6kxbarTMChUtilThreshold."
+ ::= { cc6kxbarTMChUtilEntry 5 }
+
+cc6kxbarTMChUtilThreshold OBJECT-TYPE
+ SYNTAX Percent
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Specifies the threshold of the traffic utilization
+ on a fabric channel for a given traffic direction."
+ ::= { cc6kxbarTMChUtilEntry 6 }
+
+cc6kxbarTMChUtilLogCount OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the number of times the following
+ events are logged on a fabric channel
+ for a given direction.
+
+ 1. the traffic utilization on a fabric channel
+ for a given traffic direction has risen above its
+ corresponding configured threshold (as specified
+ by cc6kxbarTMChUtilThreshold), or has kept
+ staying above the configured threshold at a
+ logging interval (as specified by
+ cc6kxbarTMChUtilLogInterval).
+
+ 2. the traffic utilization on a fabric channel
+ for a given traffic direction has fallen below
+ its corresponding configured threshold."
+ ::= { cc6kxbarTMChUtilEntry 7 }
+
+cc6kxbarTMChUtilLastLogTime OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the last logging time of the
+ events as counted in the corresponding
+ cc6kxbarTMChUtilLogCount on a fabric channel
+ for a given traffic direction.
+
+ This object will contain 0-1-1,00:00:00.0 when
+ the corresponding cc6kxbarTMChUtilLogCount is zero."
+ ::= { cc6kxbarTMChUtilEntry 8 }
+
+
+
+cc6kxbarTMChUtilLogInterval OBJECT-TYPE
+ SYNTAX Unsigned32 (1..4294967295)
+ UNITS "seconds"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Specifies the logging interval if the traffic
+ utilization for a fabric channel on a given
+ traffic direction keeps staying above its
+ corresponding cc6kxbarTMChUtilThreshold."
+ ::= { cc6kxbarTrafficMonitorChObjects 2 }
+
+cc6kxbarTMChUtilUtilization OBJECT-TYPE
+ SYNTAX Percent
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "The traffic utilization on a fabric channel
+ for a given traffic direction included in the
+ notification currently being sent."
+ ::= { cc6kxbarTrafficMonitorChObjects 3 }
+
+cc6kxbarTMChUtilNotifEnable OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Specifies whether the generation of
+ cc6kxbarTMChUtilAboveNotif and cc6kxbarTMChUtilBelowNotif
+ notifications is enabled or not.
+
+ When this object is 'true', the generation of
+ cc6kxbarTMChUtilAboveNotif and cc6kxbarTMChUtilBelowNotif
+ notifications is enabled. When this object is 'false',
+ the generation of cc6kxbarTMChUtilAboveNotif and
+ cc6kxbarTMChUtilBelowNotif notifications is disabled."
+ ::= { cc6kxbarTrafficMonitorChObjects 4 }
+-- Notifications
+
+ciscoCat6kXbarMIBNotifs OBJECT IDENTIFIER
+ ::= { ciscoCat6kCrossbarMIB 0 }
+
+
+cc6kxbarSwBusStatusChangeNotif NOTIFICATION-TYPE
+ OBJECTS {
+ cc6kxbarSwBusSwitchingStatus,
+ cc6kxbarSwBusFailureDuration
+ }
+ STATUS current
+ DESCRIPTION
+ "A cc6kxbarSwBusStatusChangeNotif notification
+ is sent by the device when there is change
+ in switching status of the switching bus as
+ monitored by cc6kxbarSwBusSwitchingStatus."
+ ::= { ciscoCat6kXbarMIBNotifs 1 }
+
+cc6kxbarIntBusCRCErrExcdNotif NOTIFICATION-TYPE
+ OBJECTS {
+ entPhysicalName,
+ entPhysicalVendorType
+ }
+ STATUS current
+ DESCRIPTION
+ "A cc6kxbarIntBusCRCThreshExcdNotif notification
+ is sent by the system when the system has
+ detected that the internal bus CRC error on
+ a physical entity (such as a module) as specified
+ by entPhysicalName has exceeded the fatal threshold."
+ ::= { ciscoCat6kXbarMIBNotifs 2 }
+
+cc6kxbarIntBusCRCErrRcvrdNotif NOTIFICATION-TYPE
+ OBJECTS {
+ entPhysicalName,
+ entPhysicalVendorType
+ }
+ STATUS current
+ DESCRIPTION
+ "A cc6kxbarIntBusCRCErrRcvrdNotif notification
+ is sent by the system when the system has
+ recovered as the internal bus CRC error on
+ a physical entity (such as a module) as
+ specified by entPhysicalName has fallen below
+ the normal threshold."
+ ::= { ciscoCat6kXbarMIBNotifs 3 }
+
+cc6kxbarFlowCtrlBusThrExcdNotif NOTIFICATION-TYPE
+ OBJECTS {
+ entPhysicalName,
+ entPhysicalVendorType
+ }
+ STATUS current
+ DESCRIPTION
+ "A cc6kxbarFlowCtrlBusThrExcdNotif notification
+ is sent by the system when the system detects the
+ first occurrence of the system bus flow control FIFO
+ threshold exceeding on a physical entity
+ (such as a module) over the system allowed limit
+ when the object value of
+ cc6kxbarFlowCtrlBusFIFOThrMode is 'auto'."
+ ::= { ciscoCat6kXbarMIBNotifs 4 }
+
+cc6kxbarTMSwBusUtilAboveNotif NOTIFICATION-TYPE
+ OBJECTS {
+ cc6kxbarTMSwBusUtilUtilization,
+ cc6kxbarTMSwBusUtilThreshold,
+ cc6kxbarTMSwBusUtilInterval,
+ entPhysicalDescr
+ }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the switching bus
+ traffic utilization has risen above the configured
+ threshold (as specified by
+ cc6kxbarTMSwBusUtilThreshold), or has kept staying
+ above the configured threshold at a logging interval
+ (as specified by cc6kxbarTMSwBusUtilLogInterval).
+ The varbind entPhysicalDescr specifies the physical
+ entity (such as chassis) for which the
+ cc6kxbarTMSwBusUtilAboveNotif is sent."
+ ::= { ciscoCat6kXbarMIBNotifs 5 }
+
+cc6kxbarTMSwBusUtilBelowNotif NOTIFICATION-TYPE
+ OBJECTS {
+ cc6kxbarTMSwBusUtilUtilization,
+ cc6kxbarTMSwBusUtilThreshold,
+ cc6kxbarTMSwBusUtilInterval,
+ entPhysicalDescr
+ }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the switching bus
+ traffic utilization has fallen below the configured
+ threshold (as specified by
+ cc6kxbarTMSwBusUtilThreshold). The varbind
+ entPhysicalDescr specifies the physical entity
+ (such as chassis) for which the
+ cc6kxbarTMSwBusUtilBelowNotif is sent."
+ ::= { ciscoCat6kXbarMIBNotifs 6 }
+
+cc6kxbarTMChUtilAboveNotif NOTIFICATION-TYPE
+ OBJECTS {
+ cc6kxbarTMChUtilUtilization,
+ cc6kxbarTMChUtilThreshold,
+ cc6kxbarTMChUtilInterval,
+ entPhysicalDescr
+ }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the traffic
+ utilization on a fabric channel for a given
+ traffic direction has risen above its
+ corresponding configured threshold (as
+ specified by cc6kxbarTMChUtilThreshold), or has
+ kept staying above the configured threshold at a
+ logging interval (as specified by
+ cc6kxbarTMChUtilLogInterval). The varbind
+ entPhysicalDescr specifies the physical entity
+ (such as chassis) for which the
+ cc6kxbarTMChUtilAboveNotif is sent."
+ ::= { ciscoCat6kXbarMIBNotifs 7 }
+
+cc6kxbarTMChUtilBelowNotif NOTIFICATION-TYPE
+ OBJECTS {
+ cc6kxbarTMChUtilUtilization,
+ cc6kxbarTMChUtilThreshold,
+ cc6kxbarTMChUtilInterval,
+ entPhysicalDescr
+ }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent when the traffic
+ utilization on a fabric channel for a given
+ traffic direction has fallen below its
+ corresponding configured threshold (as
+ specified by cc6kxbarTMChUtilThreshold). The
+ varbind entPhysicalDescr specifies the
+ physical entity (such as chassis) for which
+ the cc6kxbarTMChUtilBelowNotif is sent."
+ ::= { ciscoCat6kXbarMIBNotifs 8 }
+-- Conformance and Compliance
+
+cc6kxbarMIBConformance OBJECT IDENTIFIER
+ ::= { ciscoCat6kCrossbarMIB 3 }
+
+cc6kxbarMIBCompliances OBJECT IDENTIFIER
+ ::= { cc6kxbarMIBConformance 1 }
+
+cc6kxbarMIBGroups OBJECT IDENTIFIER
+ ::= { cc6kxbarMIBConformance 2 }
+
+
+-- Conformance
+
+cc6kxbarMIBCompliance MODULE-COMPLIANCE
+ STATUS deprecated
+ DESCRIPTION
+ "The compliance statement for
+ the CISCO-CAT6K-CROSSBAR-MIB."
+ MODULE -- this module
+ MANDATORY-GROUPS {
+ cc6kxbarModuleStatusGroup,
+ cc6kxbarChannelStatusGroup,
+ cc6kxbarChannelStatisticsGroup
+ }
+
+ GROUP cc6kxbarFallbackGroup
+ DESCRIPTION
+ "This group is mandatory only for those platforms which
+ support fallback mode feature."
+
+ GROUP cc6kxbarBusOnlyAllowedGroup
+ DESCRIPTION
+ "This group is mandatory only for those platforms which
+ support busonly mode feature."
+ ::= { cc6kxbarMIBCompliances 2 }
+
+cc6kxbarMIBComplianceVer1 MODULE-COMPLIANCE
+ STATUS deprecated
+ DESCRIPTION
+ "The compliance statement for
+ the CISCO-CAT6K-CROSSBAR-MIB."
+ MODULE -- this module
+ MANDATORY-GROUPS {
+ cc6kxbarModuleStatusGroupVer1,
+ cc6kxbarChannelStatusGroup,
+ cc6kxbarChannelStatisticsGroupVer1
+ }
+
+ GROUP cc6kxbarFallbackGroup
+ DESCRIPTION
+ "This group is mandatory only for those platforms which
+ support fallback mode feature."
+
+ GROUP cc6kxbarBusOnlyAllowedGroup
+ DESCRIPTION
+ "This group is mandatory only for those platforms which
+ support bus only mode feature."
+
+ GROUP cc6kxbarLcdBannerGroup
+ DESCRIPTION
+ "This group is mandatory only for those platforms which
+ support lcd banner feature."
+
+ GROUP cc6kxbarChannelUtilGroup
+ DESCRIPTION
+ "This group is mandatory only for those platforms which
+ support Input and Output traffic utilization on the
+ fabric channel."
+
+ GROUP cc6kxbarChannelSpeedGroup
+ DESCRIPTION
+ "This group is mandatory only for those platforms which
+ support fabric channel speed feature."
+
+ GROUP cc6kxbarSwBusGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ switching bus switching detection feature."
+
+ GROUP cc6kxbarSwBusNotifGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ switching bus switching detection notification
+ feature."
+ ::= { cc6kxbarMIBCompliances 3 }
+
+cc6kxbarMIBComplianceVer2 MODULE-COMPLIANCE
+ STATUS deprecated
+ DESCRIPTION
+ "The compliance statement for
+ the CISCO-CAT6K-CROSSBAR-MIB."
+ MODULE -- this module
+ MANDATORY-GROUPS {
+ cc6kxbarModuleStatusGroupVer1,
+ cc6kxbarChannelStatusGroup,
+ cc6kxbarChannelStatisticsGroupVer1
+ }
+
+ GROUP cc6kxbarFallbackGroup
+ DESCRIPTION
+ "This group is mandatory only for those platforms which
+ support fallback mode feature."
+
+ GROUP cc6kxbarBusOnlyAllowedGroup
+ DESCRIPTION
+ "This group is mandatory only for those platforms which
+ support bus only mode feature."
+
+ GROUP cc6kxbarLcdBannerGroup
+ DESCRIPTION
+ "This group is mandatory only for those platforms which
+ support lcd banner feature."
+
+ GROUP cc6kxbarChannelUtilGroup
+ DESCRIPTION
+ "This group is mandatory only for those platforms which
+ support Input and Output traffic utilization on the
+ fabric channel."
+
+ GROUP cc6kxbarChannelSpeedGroup
+ DESCRIPTION
+ "This group is mandatory only for those platforms which
+ support fabric channel speed feature."
+
+ GROUP cc6kxbarSwBusGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ switching bus switching detection feature."
+
+ GROUP cc6kxbarSwBusNotifGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ switching bus switching detection notification
+ feature."
+
+ GROUP cc6kxbarTruncatedOperGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ operational truncated mode."
+ ::= { cc6kxbarMIBCompliances 4 }
+
+cc6kxbarMIBComplianceVer3 MODULE-COMPLIANCE
+ STATUS deprecated
+ DESCRIPTION
+ "The compliance statement for
+ the CISCO-CAT6K-CROSSBAR-MIB."
+ MODULE -- this module
+ MANDATORY-GROUPS {
+ cc6kxbarModuleStatusGroupVer1,
+ cc6kxbarChannelStatusGroup,
+ cc6kxbarChannelStatisticsGroupVer1
+ }
+
+ GROUP cc6kxbarFallbackGroup
+ DESCRIPTION
+ "This group is mandatory only for those platforms which
+ support fallback mode feature."
+
+ GROUP cc6kxbarBusOnlyAllowedGroup
+ DESCRIPTION
+ "This group is mandatory only for those platforms which
+ support bus only mode feature."
+
+ GROUP cc6kxbarLcdBannerGroup
+ DESCRIPTION
+ "This group is mandatory only for those platforms which
+ support lcd banner feature."
+
+ GROUP cc6kxbarChannelUtilGroup
+ DESCRIPTION
+ "This group is mandatory only for those platforms which
+ support Input and Output traffic utilization on the
+ fabric channel."
+
+ GROUP cc6kxbarChannelSpeedGroup
+ DESCRIPTION
+ "This group is mandatory only for those platforms which
+ support fabric channel speed feature."
+
+ GROUP cc6kxbarSwBusGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ switching bus switching detection feature."
+
+ GROUP cc6kxbarSwBusNotifGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ switching bus switching detection notification
+ feature."
+
+ GROUP cc6kxbarTruncatedOperGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ operational truncated mode."
+
+ GROUP cc6kxbarIntBusNotifControlGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ internal bus notifications."
+
+ GROUP cc6kxbarIntBusCRCErrNotifGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ internal bus CRC error notifications."
+ ::= { cc6kxbarMIBCompliances 5 }
+
+cc6kxbarMIBComplianceVer4 MODULE-COMPLIANCE
+ STATUS deprecated
+ DESCRIPTION
+ "The compliance statement for
+ the CISCO-CAT6K-CROSSBAR-MIB."
+ MODULE -- this module
+ MANDATORY-GROUPS {
+ cc6kxbarModuleStatusGroupVer1,
+ cc6kxbarChannelStatusGroup,
+ cc6kxbarChannelStatisticsGroupVer1
+ }
+
+ GROUP cc6kxbarFallbackGroup
+ DESCRIPTION
+ "This group is mandatory only for those platforms which
+ support fallback mode feature."
+
+ GROUP cc6kxbarBusOnlyAllowedGroup
+ DESCRIPTION
+ "This group is mandatory only for those platforms which
+ support bus only mode feature."
+
+ GROUP cc6kxbarLcdBannerGroup
+ DESCRIPTION
+ "This group is mandatory only for those platforms which
+ support lcd banner feature."
+
+ GROUP cc6kxbarChannelUtilGroup
+ DESCRIPTION
+ "This group is mandatory only for those platforms which
+ support Input and Output traffic utilization on the
+ fabric channel."
+
+ GROUP cc6kxbarChannelSpeedGroup
+ DESCRIPTION
+ "This group is mandatory only for those platforms which
+ support fabric channel speed feature."
+
+ GROUP cc6kxbarSwBusGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ switching bus switching detection feature."
+
+ GROUP cc6kxbarSwBusNotifGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ switching bus switching detection notification
+ feature."
+
+ GROUP cc6kxbarTruncatedOperGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ operational truncated mode."
+
+ GROUP cc6kxbarIntBusNotifControlGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ internal bus notifications."
+
+ GROUP cc6kxbarIntBusCRCErrNotifGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ internal bus CRC error notifications."
+
+ GROUP cc6kxbarIntBusCRCErrGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ internal bus CRC error status."
+ ::= { cc6kxbarMIBCompliances 6 }
+
+cc6kxbarMIBComplianceVer5 MODULE-COMPLIANCE
+ STATUS deprecated
+ DESCRIPTION
+ "The compliance statement for
+ the CISCO-CAT6K-CROSSBAR-MIB."
+ MODULE -- this module
+ MANDATORY-GROUPS {
+ cc6kxbarModuleStatusGroupVer1,
+ cc6kxbarChannelStatusGroup,
+ cc6kxbarChannelStatisticsGroupVer1
+ }
+
+ GROUP cc6kxbarFallbackGroup
+ DESCRIPTION
+ "This group is mandatory only for those platforms which
+ support fallback mode feature."
+
+ GROUP cc6kxbarBusOnlyAllowedGroup
+ DESCRIPTION
+ "This group is mandatory only for those platforms which
+ support bus only mode feature."
+
+ GROUP cc6kxbarLcdBannerGroup
+ DESCRIPTION
+ "This group is mandatory only for those platforms which
+ support lcd banner feature."
+
+ GROUP cc6kxbarChannelUtilGroup
+ DESCRIPTION
+ "This group is mandatory only for those platforms which
+ support Input and Output traffic utilization on the
+ fabric channel."
+
+ GROUP cc6kxbarChannelSpeedGroup
+ DESCRIPTION
+ "This group is mandatory only for those platforms which
+ support fabric channel speed feature."
+
+ GROUP cc6kxbarSwBusGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ switching bus switching detection feature."
+
+ GROUP cc6kxbarSwBusNotifGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ switching bus switching detection notification
+ feature."
+
+ GROUP cc6kxbarTruncatedOperGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ operational truncated mode."
+
+ GROUP cc6kxbarIntBusNotifControlGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ internal bus notifications."
+
+ GROUP cc6kxbarIntBusCRCErrNotifGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ internal bus CRC error notifications."
+
+ GROUP cc6kxbarIntBusCRCErrGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ internal bus CRC error status."
+
+ GROUP cc6kxbarDcefOnlyModeAllowedGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ dcef only mode feature."
+
+ GROUP cc6kxbarForceBusModeGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ force bus mode feature."
+
+ GROUP cc6kxbarFlowCtrlNotifCtrlGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ the system flow control notification control."
+
+ GROUP cc6kxbarFlowCtrlBusThreshGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ the system bus flow control FIFO threshold configuration."
+
+ GROUP cc6kxbarFlowCtrlBusThrNotifGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ the system bus flow control FIFO threshold exceeding
+ notification."
+
+ GROUP cc6kxbarBusOnlyModeOperGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ operational bus mode."
+ ::= { cc6kxbarMIBCompliances 7 }
+
+cc6kxbarMIBComplianceVer6 MODULE-COMPLIANCE
+ STATUS deprecated
+ DESCRIPTION
+ "The compliance statement for
+ the CISCO-CAT6K-CROSSBAR-MIB."
+ MODULE -- this module
+ MANDATORY-GROUPS {
+ cc6kxbarModuleStatusGroupVer1,
+ cc6kxbarChannelStatusGroup,
+ cc6kxbarChannelStatisticsGroupVer1
+ }
+
+ GROUP cc6kxbarFallbackGroup
+ DESCRIPTION
+ "This group is mandatory only for those platforms which
+ support fallback mode feature."
+
+ GROUP cc6kxbarBusOnlyAllowedGroup
+ DESCRIPTION
+ "This group is mandatory only for those platforms which
+ support bus only mode feature."
+
+ GROUP cc6kxbarLcdBannerGroup
+ DESCRIPTION
+ "This group is mandatory only for those platforms which
+ support lcd banner feature."
+
+ GROUP cc6kxbarChannelUtilGroup
+ DESCRIPTION
+ "This group is mandatory only for those platforms which
+ support Input and Output traffic utilization on the
+ fabric channel."
+
+ GROUP cc6kxbarChannelSpeedGroup
+ DESCRIPTION
+ "This group is mandatory only for those platforms which
+ support fabric channel speed feature."
+
+ GROUP cc6kxbarSwBusGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ switching bus switching detection feature."
+
+ GROUP cc6kxbarSwBusNotifGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ switching bus switching detection notification
+ feature."
+
+ GROUP cc6kxbarTruncatedOperGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ operational truncated mode."
+
+ GROUP cc6kxbarIntBusNotifControlGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ internal bus notifications."
+
+ GROUP cc6kxbarIntBusCRCErrNotifGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ internal bus CRC error notifications."
+
+ GROUP cc6kxbarIntBusCRCErrGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ internal bus CRC error status."
+
+ GROUP cc6kxbarDcefOnlyModeAllowedGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ dcef only mode feature."
+
+ GROUP cc6kxbarForceBusModeGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ force bus mode feature."
+
+ GROUP cc6kxbarFlowCtrlNotifCtrlGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ the system flow control notification control."
+
+ GROUP cc6kxbarFlowCtrlBusThreshGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ the system bus flow control FIFO threshold configuration."
+
+ GROUP cc6kxbarFlowCtrlBusThrNotifGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ the system bus flow control FIFO threshold exceeding
+ notification."
+
+ GROUP cc6kxbarBusOnlyModeOperGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ operational bus mode."
+
+ GROUP cc6kxbarSysCapPfcOperModeGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which
+ support the system information of PFC operational mode."
+
+ GROUP cc6kxbarSysCapSwitchResGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which
+ support the capacity information of switching
+ resources in the system."
+
+ GROUP cc6kxbarChannelUtilGroup1
+ DESCRIPTION
+ "This group is mandatory only for those platforms which
+ support peak input and output traffic utilization on the
+ fabric channel."
+
+ GROUP cc6kxbarSwBusGroup1
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ switching bus utilization."
+
+ GROUP cc6kxbarErrorGroup
+ DESCRIPTION
+ "This group is mandatory only for those platforms which
+ support error statistics on the fabric channel."
+
+ GROUP cc6kxbarErrRcvryThresholdGroup
+ DESCRIPTION
+ "This group is mandatory for platforms which provide
+ the configuration of thresholds on fabric link errors
+ for the fabric error recovery feature."
+
+ GROUP cc6kxbarErrRcvrySwitchoverGroup
+ DESCRIPTION
+ "This group is mandatory for platforms which provide
+ the configuration of fabric switchover on excessive fabric
+ link errors for the fabric error recovery feature."
+ ::= { cc6kxbarMIBCompliances 8 }
+
+cc6kxbarMIBComplianceVer7 MODULE-COMPLIANCE
+ STATUS deprecated
+ DESCRIPTION
+ "The compliance statement for
+ the CISCO-CAT6K-CROSSBAR-MIB."
+ MODULE -- this module
+ MANDATORY-GROUPS {
+ cc6kxbarModuleStatusGroupVer1,
+ cc6kxbarChannelStatusGroup,
+ cc6kxbarChannelStatisticsGroupVer1
+ }
+
+ GROUP cc6kxbarFallbackGroup
+ DESCRIPTION
+ "This group is mandatory only for those platforms which
+ support fallback mode feature."
+
+ GROUP cc6kxbarBusOnlyAllowedGroup
+ DESCRIPTION
+ "This group is mandatory only for those platforms which
+ support bus only mode feature."
+
+ GROUP cc6kxbarLcdBannerGroup
+ DESCRIPTION
+ "This group is mandatory only for those platforms which
+ support lcd banner feature."
+
+ GROUP cc6kxbarChannelUtilGroup
+ DESCRIPTION
+ "This group is mandatory only for those platforms which
+ support Input and Output traffic utilization on the
+ fabric channel."
+
+ GROUP cc6kxbarChannelSpeedGroup
+ DESCRIPTION
+ "This group is mandatory only for those platforms which
+ support fabric channel speed feature."
+
+ GROUP cc6kxbarSwBusGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ switching bus switching detection feature."
+
+ GROUP cc6kxbarSwBusNotifGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ switching bus switching detection notification
+ feature."
+
+ GROUP cc6kxbarTruncatedOperGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ operational truncated mode."
+
+ GROUP cc6kxbarIntBusNotifControlGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ internal bus notifications."
+
+ GROUP cc6kxbarIntBusCRCErrNotifGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ internal bus CRC error notifications."
+
+ GROUP cc6kxbarIntBusCRCErrGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ internal bus CRC error status."
+
+ GROUP cc6kxbarDcefOnlyModeAllowedGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ dcef only mode feature."
+
+ GROUP cc6kxbarForceBusModeGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ force bus mode feature."
+
+ GROUP cc6kxbarFlowCtrlNotifCtrlGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ the system flow control notification control."
+
+ GROUP cc6kxbarFlowCtrlBusThreshGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ the system bus flow control FIFO threshold configuration."
+
+ GROUP cc6kxbarFlowCtrlBusThrNotifGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ the system bus flow control FIFO threshold exceeding
+ notification."
+
+ GROUP cc6kxbarBusOnlyModeOperGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ operational bus mode."
+
+ GROUP cc6kxbarSysCapPfcOperModeGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which
+ support the system information of PFC operational mode."
+
+ GROUP cc6kxbarSysCapSwitchResGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which
+ support the capacity information of switching
+ resources in the system."
+
+ GROUP cc6kxbarChannelUtilGroup1
+ DESCRIPTION
+ "This group is mandatory only for those platforms which
+ support peak input and output traffic utilization on the
+ fabric channel."
+
+ GROUP cc6kxbarSwBusGroup1
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ switching bus utilization."
+
+ GROUP cc6kxbarErrorGroup
+ DESCRIPTION
+ "This group is mandatory only for those platforms which
+ support error statistics on the fabric channel."
+
+ GROUP cc6kxbarErrRcvryThresholdGroup
+ DESCRIPTION
+ "This group is mandatory for platforms which provide
+ the configuration of thresholds on fabric link errors
+ for the fabric error recovery feature."
+
+ GROUP cc6kxbarErrRcvrySwitchoverGroup
+ DESCRIPTION
+ "This group is mandatory for platforms which provide
+ the configuration of fabric switchover on excessive fabric
+ link errors for the fabric error recovery feature."
+
+ GROUP cc6kxbarErrRcvryPersLinkResGroup
+ DESCRIPTION
+ "This group is mandatory for platforms which provide
+ the configuration of channel resync on excessive
+ persistent fabric link errors for the fabric error
+ recovery feature."
+
+ GROUP cc6kxbarErrRcvryChResyncGroup
+ DESCRIPTION
+ "This group is mandatory for platforms which provide
+ the configuration of channel resync threshold for the
+ fabric error recovery feature."
+
+ GROUP cc6kxbarTMSwBusUtilGroup
+ DESCRIPTION
+ "This group is mandatory for platforms which provide
+ the configuration for traffic monitor feature on the
+ switching bus."
+
+ GROUP cc6kxbarTMSwBusUtilNotifControlGroup
+ DESCRIPTION
+ "This group is mandatory for platforms which provide
+ the notification control for traffic monitor
+ notifications on the switching bus."
+
+ GROUP cc6kxbarTMSwBusUtilNotifObjectGroup
+ DESCRIPTION
+ "This group is mandatory for platforms which support
+ traffic monitor notifications on the switching bus."
+
+ GROUP cc6kxbarTMSwBusUtilNotifGroup
+ DESCRIPTION
+ "This group is mandatory for platforms which support
+ traffic monitor notifications on the switching bus."
+
+ GROUP cc6kxbarTMChUtilGroup
+ DESCRIPTION
+ "This group is mandatory for platforms which provide
+ the configuration for traffic monitor feature on
+ fabric channels."
+
+ GROUP cc6kxbarTMChUtilNotifControlGroup
+ DESCRIPTION
+ "This group is mandatory for platforms which provide
+ the notification control for traffic monitor
+ notifications on fabric channels."
+
+ GROUP cc6kxbarTMChUtilNotifObjectGroup
+ DESCRIPTION
+ "This group is mandatory for platforms which support
+ traffic monitor notifications on fabric channels."
+
+ GROUP cc6kxbarTMChUtilNotifGroup
+ DESCRIPTION
+ "This group is mandatory for platforms which support
+ traffic monitor notifications on fabric channels."
+ ::= { cc6kxbarMIBCompliances 9 }
+
+cc6kxbarMIBComplianceVer8 MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION
+ "The compliance statement for
+ the CISCO-CAT6K-CROSSBAR-MIB."
+ MODULE -- this module
+ MANDATORY-GROUPS {
+ cc6kxbarModuleStatusGroupVer1,
+ cc6kxbarChannelStatusGroup,
+ cc6kxbarChannelStatisticsGroupVer1
+ }
+
+ GROUP cc6kxbarFallbackGroup
+ DESCRIPTION
+ "This group is mandatory only for those platforms which
+ support fallback mode feature."
+
+ GROUP cc6kxbarBusOnlyAllowedGroup
+ DESCRIPTION
+ "This group is mandatory only for those platforms which
+ support bus only mode feature."
+
+ GROUP cc6kxbarLcdBannerGroup
+ DESCRIPTION
+ "This group is mandatory only for those platforms which
+ support lcd banner feature."
+
+ GROUP cc6kxbarChannelUtilGroup
+ DESCRIPTION
+ "This group is mandatory only for those platforms which
+ support Input and Output traffic utilization on the
+ fabric channel."
+
+ GROUP cc6kxbarChannelSpeedGroup
+ DESCRIPTION
+ "This group is mandatory only for those platforms which
+ support fabric channel speed feature."
+
+ GROUP cc6kxbarSwBusGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ switching bus switching detection feature."
+
+ GROUP cc6kxbarSwBusNotifGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ switching bus switching detection notification
+ feature."
+
+ GROUP cc6kxbarTruncatedOperGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ operational truncated mode."
+
+ GROUP cc6kxbarIntBusNotifControlGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ internal bus notifications."
+
+ GROUP cc6kxbarIntBusCRCErrNotifGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ internal bus CRC error notifications."
+
+ GROUP cc6kxbarIntBusCRCErrGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ internal bus CRC error status."
+
+ GROUP cc6kxbarDcefOnlyModeAllowedGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ dcef only mode feature."
+
+ GROUP cc6kxbarForceBusModeGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ force bus mode feature."
+
+ GROUP cc6kxbarFlowCtrlNotifCtrlGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ the system flow control notification control."
+
+ GROUP cc6kxbarFlowCtrlBusThreshGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ the system bus flow control FIFO threshold configuration."
+
+ GROUP cc6kxbarFlowCtrlBusThrNotifGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ the system bus flow control FIFO threshold exceeding
+ notification."
+
+ GROUP cc6kxbarBusOnlyModeOperGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ operational bus mode."
+
+ GROUP cc6kxbarSysCapPfcOperModeGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which
+ support the system information of PFC operational mode."
+
+ GROUP cc6kxbarSysCapSwitchResGroup
+ DESCRIPTION
+ "This group is mandatory only for platforms which
+ support the capacity information of switching
+ resources in the system."
+
+ GROUP cc6kxbarChannelUtilGroup1
+ DESCRIPTION
+ "This group is mandatory only for those platforms which
+ support peak input and output traffic utilization on the
+ fabric channel."
+
+ GROUP cc6kxbarSwBusGroup1
+ DESCRIPTION
+ "This group is mandatory only for platforms which support
+ switching bus utilization."
+
+ GROUP cc6kxbarErrorGroup
+ DESCRIPTION
+ "This group is mandatory only for those platforms which
+ support error statistics on the fabric channel."
+
+ GROUP cc6kxbarErrRcvryThresholdGroup
+ DESCRIPTION
+ "This group is mandatory for platforms which provide
+ the configuration of thresholds on fabric link errors
+ for the fabric error recovery feature."
+
+ GROUP cc6kxbarErrRcvrySwitchoverGroup
+ DESCRIPTION
+ "This group is mandatory for platforms which provide
+ the configuration of fabric switchover on excessive fabric
+ link errors for the fabric error recovery feature."
+
+ GROUP cc6kxbarErrRcvryPersLinkResGroup
+ DESCRIPTION
+ "This group is mandatory for platforms which provide
+ the configuration of channel resync on excessive
+ persistent fabric link errors for the fabric error
+ recovery feature."
+
+ GROUP cc6kxbarErrRcvryChResyncGroup
+ DESCRIPTION
+ "This group is mandatory for platforms which provide
+ the configuration of channel resync threshold for the
+ fabric error recovery feature."
+
+ GROUP cc6kxbarTMSwBusUtilGroup
+ DESCRIPTION
+ "This group is mandatory for platforms which provide
+ the configuration for traffic monitor feature on the
+ switching bus."
+
+ GROUP cc6kxbarTMSwBusUtilNotifControlGroup
+ DESCRIPTION
+ "This group is mandatory for platforms which provide
+ the notification control for traffic monitor
+ notifications on the switching bus."
+
+ GROUP cc6kxbarTMSwBusUtilNotifObjectGroup
+ DESCRIPTION
+ "This group is mandatory for platforms which support
+ traffic monitor notifications on the switching bus."
+
+ GROUP cc6kxbarTMSwBusUtilNotifGroup
+ DESCRIPTION
+ "This group is mandatory for platforms which support
+ traffic monitor notifications on the switching bus."
+
+ GROUP cc6kxbarTMChUtilGroup
+ DESCRIPTION
+ "This group is mandatory for platforms which provide
+ the configuration for traffic monitor feature on
+ fabric channels."
+
+ GROUP cc6kxbarTMChUtilNotifControlGroup
+ DESCRIPTION
+ "This group is mandatory for platforms which provide
+ the notification control for traffic monitor
+ notifications on fabric channels."
+
+ GROUP cc6kxbarTMChUtilNotifObjectGroup
+ DESCRIPTION
+ "This group is mandatory for platforms which support
+ traffic monitor notifications on fabric channels."
+
+ GROUP cc6kxbarTMChUtilNotifGroup
+ DESCRIPTION
+ "This group is mandatory for platforms which support
+ traffic monitor notifications on fabric channels."
+
+ GROUP cc6kxbarStatisticsLbusDropGroup
+ DESCRIPTION
+ "This group is mandatory for platforms which support
+ local bus packet drop statistics on fabric channels."
+ ::= { cc6kxbarMIBCompliances 10 }
+
+-- Units of Conformance
+
+cc6kxbarModuleStatusGroup OBJECT-GROUP
+ OBJECTS {
+ cc6kxbarLcdBannerMaxSize,
+ cc6kxbarLcdBannerBanner,
+ cc6kxbarTruncatedModeAllowed,
+ cc6kxbarMinFabricPresent,
+ cc6kxbarFabricActiveSlot,
+ cc6kxbarFabricBackupSlot,
+ cc6kxbarModuleModeSwitchingMode
+ }
+ STATUS deprecated
+ DESCRIPTION
+ "A collection of objects providing
+ configuration and operation of the crossbar
+ switching fabric module and switching capable
+ module.
+ cc6kxbarModuleStatusGroup object is superseded by cc6kxbarModuleStatusGroupVer1."
+ ::= { cc6kxbarMIBGroups 1 }
+
+cc6kxbarChannelStatusGroup OBJECT-GROUP
+ OBJECTS {
+ cc6kxbarModuleChannelModStatus,
+ cc6kxbarModuleChannelFabStatus
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing
+ status and configuration of the fabric channel."
+ ::= { cc6kxbarMIBGroups 2 }
+
+cc6kxbarChannelStatisticsGroup OBJECT-GROUP
+ OBJECTS {
+ cc6kxbarStatisticsInErrors,
+ cc6kxbarStatisticsOutErrors,
+ cc6kxbarStatisticsOutDropped,
+ cc6kxbarStatisticsInUtil,
+ cc6kxbarStatisticsOutUtil
+ }
+ STATUS deprecated
+ DESCRIPTION
+ "A collection of objects providing statistics for
+ the fabric channel.
+ cc6kxbarChannelStatisticsGroup object is superseded by cc6kxbarChannelStatisticsGroupVer1."
+ ::= { cc6kxbarMIBGroups 3 }
+
+cc6kxbarFallbackGroup OBJECT-GROUP
+ OBJECTS { cc6kxbarFallbackMode }
+ STATUS current
+ DESCRIPTION
+ "This object controls system fallback to bus-mode
+ after loss of switching fabric module."
+ ::= { cc6kxbarMIBGroups 4 }
+
+cc6kxbarBusOnlyAllowedGroup OBJECT-GROUP
+ OBJECTS { cc6kxbarBusOnlyModeAllowed }
+ STATUS current
+ DESCRIPTION
+ "This object determines the value of
+ cc6kxbarModuleModeSwitchingMode of each module."
+ ::= { cc6kxbarMIBGroups 5 }
+
+cc6kxbarModuleStatusGroupVer1 OBJECT-GROUP
+ OBJECTS {
+ cc6kxbarTruncatedModeAllowed,
+ cc6kxbarMinFabricPresent,
+ cc6kxbarFabricActiveSlot,
+ cc6kxbarFabricBackupSlot,
+ cc6kxbarModuleModeSwitchingMode
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing
+ configuration and operation of the crossbar
+ switching fabric module and switching capable
+ module."
+ ::= { cc6kxbarMIBGroups 6 }
+
+cc6kxbarChannelStatisticsGroupVer1 OBJECT-GROUP
+ OBJECTS {
+ cc6kxbarStatisticsInErrors,
+ cc6kxbarStatisticsOutErrors,
+ cc6kxbarStatisticsOutDropped
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing statistics for
+ the fabric channel."
+ ::= { cc6kxbarMIBGroups 7 }
+
+cc6kxbarLcdBannerGroup OBJECT-GROUP
+ OBJECTS {
+ cc6kxbarLcdBannerMaxSize,
+ cc6kxbarLcdBannerBanner
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing configuration of
+ the lcd Banner of the fabric module."
+ ::= { cc6kxbarMIBGroups 8 }
+
+cc6kxbarChannelUtilGroup OBJECT-GROUP
+ OBJECTS {
+ cc6kxbarStatisticsInUtil,
+ cc6kxbarStatisticsOutUtil
+ }
+ STATUS current
+ DESCRIPTION
+ "These object determines Input and Output Utilization of the
+ fabric channel."
+ ::= { cc6kxbarMIBGroups 9 }
+
+cc6kxbarChannelSpeedGroup OBJECT-GROUP
+ OBJECTS { cc6kxbarModuleChannelSpeed }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing the
+ speed of the fabric channel."
+ ::= { cc6kxbarMIBGroups 10 }
+
+cc6kxbarSwBusGroup OBJECT-GROUP
+ OBJECTS {
+ cc6kxbarSwBusSwitchingStatus,
+ cc6kxbarSwBusFailureDuration,
+ cc6kxbarSwBusNotifEnable
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects for the switching bus switching
+ detection feature."
+ ::= { cc6kxbarMIBGroups 11 }
+
+cc6kxbarSwBusNotifGroup NOTIFICATION-GROUP
+ NOTIFICATIONS { cc6kxbarSwBusStatusChangeNotif }
+ STATUS current
+ DESCRIPTION
+ "A collection of notifications for the switching
+ bus switching detection feature."
+ ::= { cc6kxbarMIBGroups 12 }
+
+cc6kxbarTruncatedOperGroup OBJECT-GROUP
+ OBJECTS { cc6kxbarTruncatedModeOper }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing the
+ operational truncated mode."
+ ::= { cc6kxbarMIBGroups 13 }
+
+cc6kxbarIntBusNotifControlGroup OBJECT-GROUP
+ OBJECTS { cc6kxbarIntBusNotifEnable }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects to control the notification
+ generation for internal bus."
+ ::= { cc6kxbarMIBGroups 14 }
+
+cc6kxbarIntBusCRCErrNotifGroup NOTIFICATION-GROUP
+ NOTIFICATIONS {
+ cc6kxbarIntBusCRCErrExcdNotif,
+ cc6kxbarIntBusCRCErrRcvrdNotif
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of notifications for the
+ internal bus CRC error."
+ ::= { cc6kxbarMIBGroups 15 }
+
+cc6kxbarIntBusCRCErrGroup OBJECT-GROUP
+ OBJECTS {
+ cc6kxbarIntBusCRCErrExcdStatus,
+ cc6kxbarIntBusCRCErrExcdCount
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects to indicate the internal bus
+ CRC error information on a physical entity."
+ ::= { cc6kxbarMIBGroups 16 }
+
+cc6kxbarDcefOnlyModeAllowedGroup OBJECT-GROUP
+ OBJECTS { cc6kxbarDcefOnlyModeAllowed }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing the configuration
+ and information about the dcef only mode feature."
+ ::= { cc6kxbarMIBGroups 17 }
+
+cc6kxbarForceBusModeGroup OBJECT-GROUP
+ OBJECTS { cc6kxbarForceBusMode }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing the configuration
+ and information about the force bus mode feature."
+ ::= { cc6kxbarMIBGroups 18 }
+
+cc6kxbarFlowCtrlNotifCtrlGroup OBJECT-GROUP
+ OBJECTS { cc6kxbarFlowCtrlNotifEnable }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects to control the notification
+ generation for the system flow control feature."
+ ::= { cc6kxbarMIBGroups 19 }
+
+cc6kxbarFlowCtrlBusThreshGroup OBJECT-GROUP
+ OBJECTS {
+ cc6kxbarFlowCtrlBusFIFOThrMode,
+ cc6kxbarFlowCtrlBusFIFOThrValue,
+ cc6kxbarFlowCtrlBusFIFOTransTime
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing configuration
+ information about the system bus flow control FIFO
+ threshold."
+ ::= { cc6kxbarMIBGroups 20 }
+
+cc6kxbarFlowCtrlBusThrNotifGroup NOTIFICATION-GROUP
+ NOTIFICATIONS { cc6kxbarFlowCtrlBusThrExcdNotif }
+ STATUS current
+ DESCRIPTION
+ "A collection of notifications for the system bus
+ flow control FIFO threshold exceeding."
+ ::= { cc6kxbarMIBGroups 21 }
+
+cc6kxbarBusOnlyModeOperGroup OBJECT-GROUP
+ OBJECTS { cc6kxbarBusOnlyModeOper }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing the
+ operational bus mode."
+ ::= { cc6kxbarMIBGroups 22 }
+
+cc6kxbarSysCapPfcOperModeGroup OBJECT-GROUP
+ OBJECTS { cc6kxbarSysCapPfcOperMode }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing the system
+ information of PFC operational mode."
+ ::= { cc6kxbarMIBGroups 23 }
+
+cc6kxbarSysCapSwitchResGroup OBJECT-GROUP
+ OBJECTS {
+ cc6kxbarSysCapSwitchResSeries,
+ cc6kxbarSysCapSwitchResCefMode
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing the capacity
+ information of switching resources in the system."
+ ::= { cc6kxbarMIBGroups 24 }
+
+cc6kxbarChannelUtilGroup1 OBJECT-GROUP
+ OBJECTS {
+ cc6kxbarStatisticsPeakInUtil,
+ cc6kxbarStatisticsPeakTmInUtil,
+ cc6kxbarStatisticsPeakOutUtil,
+ cc6kxbarStatisticsPeakTmOutUtil
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing the information about peak
+ input and output utilization of a specific fabric channel on
+ a specific module."
+ ::= { cc6kxbarMIBGroups 25 }
+
+cc6kxbarSwBusGroup1 OBJECT-GROUP
+ OBJECTS {
+ cc6kxbarSwBusUtilization,
+ cc6kxbarSwBusPeakUtilization,
+ cc6kxbarSwBusPeakTimeUtil
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing the information about
+ switching bus utilization."
+ ::= { cc6kxbarMIBGroups 26 }
+
+cc6kxbarErrorGroup OBJECT-GROUP
+ OBJECTS {
+ cc6kxbarErrorModuleCrc,
+ cc6kxbarErrorModuleHbeat,
+ cc6kxbarErrorModuleSync,
+ cc6kxbarErrorModuleDDRSync,
+ cc6kxbarErrorChannelSync,
+ cc6kxbarErrorChannelBuffer,
+ cc6kxbarErrorChannelTimeout
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing error statistics for
+ a specific fabric channel on a specific module."
+ ::= { cc6kxbarMIBGroups 27 }
+
+cc6kxbarErrRcvryThresholdGroup OBJECT-GROUP
+ OBJECTS {
+ cc6kxbarErrRcvryThreshLink,
+ cc6kxbarErrRcvryThreshPersLink
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing the configuration
+ of thresholds on fabric link errors for the fabric
+ error recovery feature."
+ ::= { cc6kxbarMIBGroups 28 }
+
+cc6kxbarErrRcvrySwitchoverGroup OBJECT-GROUP
+ OBJECTS { cc6kxbarErrRcvrySwitchoverEnable }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing the configuration
+ of fabric switchover on excessive fabric link errors
+ for the fabric error recovery feature."
+ ::= { cc6kxbarMIBGroups 29 }
+
+cc6kxbarErrRcvryPersLinkResGroup OBJECT-GROUP
+ OBJECTS { cc6kxbarErrRcvryPersLinkResync }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing the configuration
+ of channel resync on excessive persistent fabric link
+ errors for the fabric error recovery feature."
+ ::= { cc6kxbarMIBGroups 30 }
+
+cc6kxbarErrRcvryChResyncGroup OBJECT-GROUP
+ OBJECTS {
+ cc6kxbarErrRcvryChResyncCount,
+ cc6kxbarErrRcvryChResyncInterval
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing the configuration
+ for channel resync threshold for the fabric error
+ recovery feature."
+ ::= { cc6kxbarMIBGroups 31 }
+
+cc6kxbarTMSwBusUtilGroup OBJECT-GROUP
+ OBJECTS {
+ cc6kxbarTMSwBusUtilEnable,
+ cc6kxbarTMSwBusUtilInterval,
+ cc6kxbarTMSwBusUtilThreshold,
+ cc6kxbarTMSwBusUtilLogCount,
+ cc6kxbarTMSwBusUtilLastLogTime,
+ cc6kxbarTMSwBusUtilLogInterval
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing configuration
+ information for traffic monitor feature on
+ the switching bus."
+ ::= { cc6kxbarMIBGroups 32 }
+
+cc6kxbarTMSwBusUtilNotifControlGroup OBJECT-GROUP
+ OBJECTS { cc6kxbarTMSwBusUtilNotifEnable }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects to control the traffic monitor
+ notification generation on the switching bus."
+ ::= { cc6kxbarMIBGroups 33 }
+
+cc6kxbarTMSwBusUtilNotifObjectGroup OBJECT-GROUP
+ OBJECTS { cc6kxbarTMSwBusUtilUtilization }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects included in the traffic monitor
+ notifications on the switching bus."
+ ::= { cc6kxbarMIBGroups 34 }
+
+cc6kxbarTMSwBusUtilNotifGroup NOTIFICATION-GROUP
+ NOTIFICATIONS {
+ cc6kxbarTMSwBusUtilAboveNotif,
+ cc6kxbarTMSwBusUtilBelowNotif
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of traffic monitor notifications on the
+ switching bus."
+ ::= { cc6kxbarMIBGroups 35 }
+
+cc6kxbarTMChUtilGroup OBJECT-GROUP
+ OBJECTS {
+ cc6kxbarTMChUtilEnable,
+ cc6kxbarTMChUtilInterval,
+ cc6kxbarTMChUtilThreshold,
+ cc6kxbarTMChUtilLogCount,
+ cc6kxbarTMChUtilLastLogTime,
+ cc6kxbarTMChUtilLogInterval
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing the configuration
+ information for traffic monitor feature on fabric
+ channels."
+ ::= { cc6kxbarMIBGroups 36 }
+
+cc6kxbarTMChUtilNotifControlGroup OBJECT-GROUP
+ OBJECTS { cc6kxbarTMChUtilNotifEnable }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects to control the traffic monitor
+ notification generation on fabric channels."
+ ::= { cc6kxbarMIBGroups 37 }
+
+cc6kxbarTMChUtilNotifObjectGroup OBJECT-GROUP
+ OBJECTS { cc6kxbarTMChUtilUtilization }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects included in the traffic monitor
+ notifications on fabric channels."
+ ::= { cc6kxbarMIBGroups 38 }
+
+cc6kxbarTMChUtilNotifGroup NOTIFICATION-GROUP
+ NOTIFICATIONS {
+ cc6kxbarTMChUtilAboveNotif,
+ cc6kxbarTMChUtilBelowNotif
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of traffic monitor notifications on
+ fabric channels."
+ ::= { cc6kxbarMIBGroups 39 }
+
+cc6kxbarStatisticsLbusDropGroup OBJECT-GROUP
+ OBJECTS { cc6kxbarStatisticsLbusDrops }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing information for
+ local bus drop packets statistics."
+ ::= { cc6kxbarMIBGroups 40 }
+
+END
+
+
+