diff --git a/MIBS/audiocodes/AC-SS7-MIB b/MIBS/audiocodes/AC-SS7-MIB new file mode 100644 index 0000000..3f580b4 --- /dev/null +++ b/MIBS/audiocodes/AC-SS7-MIB @@ -0,0 +1,4794 @@ +
+AC-SS7-MIB DEFINITIONS ::= BEGIN
+
+
+ IMPORTS
+
+
+ OBJECT-TYPE,
+ MODULE-IDENTITY FROM SNMPv2-SMI
+ TAddress,
+ DisplayString,
+ DateAndTime, TEXTUAL-CONVENTION FROM SNMPv2-TC
+ IpAddress FROM RFC1155-SMI
+ Unsigned32,
+ Integer32,
+ enterprises FROM SNMPv2-SMI
+ RowStatus FROM SNMPv2-TC
+ SnmpAdminString FROM SNMP-FRAMEWORK-MIB
+ InetAddressType, InetAddress FROM INET-ADDRESS-MIB
+ MODULE-COMPLIANCE, OBJECT-GROUP,
+ NOTIFICATION-GROUP FROM SNMPv2-CONF
+ audioCodes,
+ acRegistrations,
+ acGeneric,
+ acProducts,acBoardMibs FROM AUDIOCODES-TYPES-MIB;
+
+
+acSS7 MODULE-IDENTITY
+ LAST-UPDATED "201207260528Z" --Thursday, July 26 2012
+ ORGANIZATION "AudioCodes Ltd"
+ CONTACT-INFO
+ "Postal: Support
+ AudioCodes LTD
+ 1 Hayarden Street
+ Airport City
+ Lod, ISRAEL 70151
+ Tel: 972-3-9764000
+ Fax: 972-3-9764040
+ Email: support@audiocodes.com
+ Web: www.audiocodes.com"
+
+ DESCRIPTION
+ ""
+
+
+
+ ::= {acBoardMibs 12}
+
+
+
+
+
+
+
+
+ acSS7Configuration OBJECT IDENTIFIER ::= {acSS7 1}
+
+
+ acSS7MTP2 OBJECT IDENTIFIER ::= {acSS7Configuration 1}
+
+
+ acSS7MTP2M3bSlDiscardCongThreshold OBJECT-TYPE
+ SYNTAX Unsigned32 (0..255)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This parameter concerns feature that prevents uncontrolled increase
+of the MTP2 Transmit queue when the upper levels ignores
+the usual flow control mechanism.
+Any new SL_TX_MSU_RQ is discarded when the number of msu queued
+on the TB or RTB overtakes the threshold.
+Value 0, means that this feature is not activated.
+Access: Offline.
+AC INI-Param: SS7M3bSlDiscardCongThreshold"
+ ::= {acSS7MTP2 1}
+
+
+
+ -- ****************************************
+ -- acSS7MTP2Attrib table declaration
+ -- ****************************************
+ acSS7MTP2AttribTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcSS7MTP2AttribEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ ::= {acSS7MTP2 21}
+
+
+
+ -- ****************************************
+ -- acSS7MTP2Attrib table entry
+ -- ****************************************
+ acSS7MTP2AttribEntry OBJECT-TYPE
+ SYNTAX AcSS7MTP2AttribEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX {acSS7MTP2AttribIndex}
+ ::= {acSS7MTP2AttribTable 1}
+
+
+
+ -- ****************************************
+ -- acSS7MTP2Attrib TABLE
+ -- ****************************************
+ AcSS7MTP2AttribEntry ::= SEQUENCE {
+ acSS7MTP2AttribIndex Unsigned32,
+ acSS7MTP2AttribIsUsed INTEGER,
+ acSS7MTP2AttribLinkRate SnmpAdminString,
+ acSS7MTP2AttribErrorCorectionMethod SnmpAdminString,
+ acSS7MTP2AttribIacCp Unsigned32,
+ acSS7MTP2AttribSUERMThreshold Unsigned32,
+ acSS7MTP2AttribAERMNormalThreshold Unsigned32,
+ acSS7MTP2AttribAERMEmerglThreshold Unsigned32,
+ acSS7MTP2AttribSUERMSigUnitDThreshold Unsigned32,
+ acSS7MTP2AttribOctetCounting Unsigned32,
+ acSS7MTP2AttribTimerT1 Unsigned32,
+ acSS7MTP2AttribTimerT2 Unsigned32,
+ acSS7MTP2AttribTimerT3 Unsigned32,
+ acSS7MTP2AttribTimerT4Normal Unsigned32,
+ acSS7MTP2AttribTimerT4Emerg Unsigned32,
+ acSS7MTP2AttribTimerT5 Unsigned32,
+ acSS7MTP2AttribTimerT6 Unsigned32,
+ acSS7MTP2AttribTimerT7 Unsigned32,
+ acSS7MTP2AttribLSSULength Unsigned32,
+ acSS7MTP2AttribPcrN2 Unsigned32,
+ acSS7MTP2AttribRowStatus RowStatus
+ }
+
+
+
+ acSS7MTP2AttribIndex OBJECT-TYPE
+ SYNTAX Unsigned32 (0..3)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Index Field for line.
+AC INI-Param: SS7Mtp2Parms_Index"
+ ::= {acSS7MTP2AttribEntry 1}
+
+
+
+ acSS7MTP2AttribIsUsed OBJECT-TYPE
+ SYNTAX INTEGER {
+ no(0)
+,
+ yes(1)
+
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Is the row used by alink.
+If it is the entrow will be read.
+AC INI-Param: N/A"
+ ::= {acSS7MTP2AttribEntry 2}
+
+
+
+ acSS7MTP2AttribLinkRate OBJECT-TYPE
+ SYNTAX SnmpAdminString (SIZE (0..1))
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Defines the SS7 SLI Link Rate.
+Choose either:
+A = 64 kbps
+D = 56 kbps
+0 = 64 kbps.
+Access: Online.
+AC INI-Param: SS7Mtp2Parms_LinkRate"
+ ::= {acSS7MTP2AttribEntry 3}
+
+
+
+ acSS7MTP2AttribErrorCorectionMethod OBJECT-TYPE
+ SYNTAX SnmpAdminString (SIZE (0..1))
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Defines the SLI error correction method.
+B = Basic
+P = PCR (Preventive Cyclic Retransmission).
+Access: Online.
+AC INI-Param: SS7Mtp2Parms_ErrorCorrectionMethod"
+ ::= {acSS7MTP2AttribEntry 4}
+
+
+
+ acSS7MTP2AttribIacCp OBJECT-TYPE
+ SYNTAX Unsigned32 (0..10)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Defines the number of aborted proving attempts before sending
+an out-of-service to MTP-3.
+Access: Online.
+AC INI-Param: SS7Mtp2Parms_IacCp"
+ ::= {acSS7MTP2AttribEntry 5}
+
+
+
+ acSS7MTP2AttribSUERMThreshold OBJECT-TYPE
+ SYNTAX Unsigned32 (0..256)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Defines the SS7 SUERM (Signal Unit Error Rate Monitor) T threshold.
+Access: Online.
+AC INI-Param: SS7Mtp2Parms_SuermT"
+ ::= {acSS7MTP2AttribEntry 6}
+
+
+
+ acSS7MTP2AttribAERMNormalThreshold OBJECT-TYPE
+ SYNTAX Unsigned32 (0..20)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Normal AERM (alignment error rate monitor) threshold [0 to 20].
+Access: Online.
+AC INI-Param: SS7Mtp2Parms_AermTin"
+ ::= {acSS7MTP2AttribEntry 7}
+
+
+
+ acSS7MTP2AttribAERMEmerglThreshold OBJECT-TYPE
+ SYNTAX Unsigned32 (0..10)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Emergency AERM (alignment error rate monitor) threshold [0 to
+10].
+Access: Online.
+AC INI-Param: SS7Mtp2Parms_AermTie"
+ ::= {acSS7MTP2AttribEntry 8}
+
+
+
+ acSS7MTP2AttribSUERMSigUnitDThreshold OBJECT-TYPE
+ SYNTAX Unsigned32 (0..256)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Defines the SS7 Signal Unit error rate monitor D threshold.
+Access: Online.
+AC INI-Param: SS7Mtp2Parms_SuermSuD"
+ ::= {acSS7MTP2AttribEntry 9}
+
+
+
+ acSS7MTP2AttribOctetCounting OBJECT-TYPE
+ SYNTAX Unsigned32 (0..256)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Defines the SS7 MTP2 Octet received while the OCTET is in counting
+mode (# of Octets received - N Octets - while in Octet
+counting mode).
+Access: Online.
+AC INI-Param: SS7Mtp2Parms_OctetCounting"
+ ::= {acSS7MTP2AttribEntry 10}
+
+
+
+ acSS7MTP2AttribTimerT1 OBJECT-TYPE
+ SYNTAX Unsigned32 (0..100000)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Defines the SS7 MTP2 T1 alignment ready timer (in msecs).
+Access: Online.
+AC INI-Param: SS7Mtp2Parms_T1"
+ ::= {acSS7MTP2AttribEntry 11}
+
+
+
+ acSS7MTP2AttribTimerT2 OBJECT-TYPE
+ SYNTAX Unsigned32 (0..200000)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Defines the SS7 MTP2 T2 unaligned timer (in msecs).
+Access: Online.
+AC INI-Param: SS7Mtp2Parms_T2"
+ ::= {acSS7MTP2AttribEntry 12}
+
+
+
+ acSS7MTP2AttribTimerT3 OBJECT-TYPE
+ SYNTAX Unsigned32 (0..20000)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Defines the SS7 MTP2 T3 timer aligned.
+Access: Online.
+AC INI-Param: SS7Mtp2Parms_T3"
+ ::= {acSS7MTP2AttribEntry 13}
+
+
+
+ acSS7MTP2AttribTimerT4Normal OBJECT-TYPE
+ SYNTAX Unsigned32 (0..15000)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Defines the SS7 MTP2 T4n Normal proving period timer.
+Access: Online.
+AC INI-Param: SS7Mtp2Parms_T4n"
+ ::= {acSS7MTP2AttribEntry 14}
+
+
+
+ acSS7MTP2AttribTimerT4Emerg OBJECT-TYPE
+ SYNTAX Unsigned32 (0..5000)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Defines the SS7 MTP2 T4e Emergency proving period timer (msec).
+Access: Online.
+AC INI-Param: SS7Mtp2Parms_T4e"
+ ::= {acSS7MTP2AttribEntry 15}
+
+
+
+ acSS7MTP2AttribTimerT5 OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2400)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Defines the SS7 MTP2 Sending SIB timer.
+Access: Online.
+AC INI-Param: SS7Mtp2Parms_T5"
+ ::= {acSS7MTP2AttribEntry 16}
+
+
+
+ acSS7MTP2AttribTimerT6 OBJECT-TYPE
+ SYNTAX Unsigned32 (0..10000)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Defines the SS7 MTP2 Remote Congestion timer (in msec).
+Access: Online.
+AC INI-Param: SS7Mtp2Parms_T6"
+ ::= {acSS7MTP2AttribEntry 17}
+
+
+
+ acSS7MTP2AttribTimerT7 OBJECT-TYPE
+ SYNTAX Unsigned32 (0..5000)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Defines the SS7 MTP2 excessive delay of the ack timer (in msec).
+Access: Online.
+AC INI-Param: SS7Mtp2Parms_T7"
+ ::= {acSS7MTP2AttribEntry 18}
+
+
+
+ acSS7MTP2AttribLSSULength OBJECT-TYPE
+ SYNTAX Unsigned32 (1..2)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Defines the SS7 MTP2 LSSU length as 1 or 2 (bytes).
+Access: Online.
+AC INI-Param: SS7Mtp2Parms_LssuLength"
+ ::= {acSS7MTP2AttribEntry 19}
+
+
+
+ acSS7MTP2AttribPcrN2 OBJECT-TYPE
+ SYNTAX Unsigned32 (0..512)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This parameter is used to define Preventive Cyclic Retransmission
+- the number of message signal unit octets available for
+retransmission (ITU-T Q703 6.4 - Forced retransmission).
+Access: Online.
+AC INI-Param: SS7Mtp2Parms_PcrN2"
+ ::= {acSS7MTP2AttribEntry 20}
+
+
+
+ acSS7MTP2AttribRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS obsolete
+ DESCRIPTION
+ "ROWSTATUS Field for line.
+AC INI-Param: N/A"
+ ::= {acSS7MTP2AttribEntry 21}
+
+
+
+ acSS7Timers OBJECT IDENTIFIER ::= {acSS7Configuration 2}
+
+
+ -- ****************************************
+ -- acSS7SignalingNodeTimers table declaration
+ -- ****************************************
+ acSS7SignalingNodeTimersTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcSS7SignalingNodeTimersEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ ::= {acSS7Timers 21}
+
+
+
+ -- ****************************************
+ -- acSS7SignalingNodeTimers table entry
+ -- ****************************************
+ acSS7SignalingNodeTimersEntry OBJECT-TYPE
+ SYNTAX AcSS7SignalingNodeTimersEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX {acSS7SignalingNodeTimersIndex}
+ ::= {acSS7SignalingNodeTimersTable 1}
+
+
+
+ -- ****************************************
+ -- acSS7SignalingNodeTimers TABLE
+ -- ****************************************
+ AcSS7SignalingNodeTimersEntry ::= SEQUENCE {
+ acSS7SignalingNodeTimersIndex Unsigned32,
+ acSS7SignalingNodeTimersIsUsed INTEGER,
+ acSS7SignalingNodeTimersAction INTEGER,
+ acSS7SignalingNodeTimersActionResult INTEGER,
+ acSS7SignalingNodeTimersName SnmpAdminString,
+ acSS7SignalingNodeTimersT6 Unsigned32,
+ acSS7SignalingNodeTimersT8 Unsigned32,
+ acSS7SignalingNodeTimersT10 Unsigned32,
+ acSS7SignalingNodeTimersT11 Unsigned32,
+ acSS7SignalingNodeTimersT15 Unsigned32,
+ acSS7SignalingNodeTimersT16 Unsigned32,
+ acSS7SignalingNodeTimersT18ITU Unsigned32,
+ acSS7SignalingNodeTimersT19ITU Unsigned32,
+ acSS7SignalingNodeTimersT20ITU Unsigned32,
+ acSS7SignalingNodeTimersT21ITU Unsigned32,
+ acSS7SignalingNodeTimersT24ITU Unsigned32,
+ acSS7SignalingNodeTimersT22ANSI Unsigned32,
+ acSS7SignalingNodeTimersT23ANSI Unsigned32,
+ acSS7SignalingNodeTimersT24ANSI Unsigned32,
+ acSS7SignalingNodeTimersT25ANSI Unsigned32,
+ acSS7SignalingNodeTimersT26ANSI Unsigned32,
+ acSS7SignalingNodeTimersT27ANSI Unsigned32,
+ acSS7SignalingNodeTimersT28ANSI Unsigned32,
+ acSS7SignalingNodeTimersT29ANSI Unsigned32,
+ acSS7SignalingNodeTimersT30ANSI Unsigned32
+ }
+
+
+
+ acSS7SignalingNodeTimersIndex OBJECT-TYPE
+ SYNTAX Unsigned32 (0..4)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Index Field for line.
+AC INI-Param: SS7_SNTIMERS_INDEX"
+ ::= {acSS7SignalingNodeTimersEntry 1}
+
+
+
+ acSS7SignalingNodeTimersIsUsed OBJECT-TYPE
+ SYNTAX INTEGER {
+ no(0)
+,
+ yes(1)
+
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "
+AC INI-Param: N/A"
+ ::= {acSS7SignalingNodeTimersEntry 2}
+
+
+
+ acSS7SignalingNodeTimersAction OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(0)
+
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "management Field for ACTIONS.
+AC INI-Param: SS7_SNTIMERS_ACTION"
+ ::= {acSS7SignalingNodeTimersEntry 3}
+
+
+
+ acSS7SignalingNodeTimersActionResult OBJECT-TYPE
+ SYNTAX INTEGER {
+ succeeded(0)
+,
+ inProgress(1)
+,
+ failed(2)
+
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "management Field for ACTIONS RESULT.
+AC INI-Param: SS7_SNTIMERS_ACTION_RESULT"
+ ::= {acSS7SignalingNodeTimersEntry 4}
+
+
+
+ acSS7SignalingNodeTimersName OBJECT-TYPE
+ SYNTAX SnmpAdminString (SIZE (0..15))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "String name for SN timer-set.
+Access: Online.
+AC INI-Param: SS7_SNTIMERS_NAME"
+ ::= {acSS7SignalingNodeTimersEntry 5}
+
+
+
+ acSS7SignalingNodeTimersT6 OBJECT-TYPE
+ SYNTAX Unsigned32 (500..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Delay to avoid message mis-sequencing on controlled rerouting.
+Access: Online.
+AC INI-Param: SS7_SNTIMERS_T6"
+ ::= {acSS7SignalingNodeTimersEntry 6}
+
+
+
+ acSS7SignalingNodeTimersT8 OBJECT-TYPE
+ SYNTAX Unsigned32 (500..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Transfer prohibited inhibition timer (transient solution).
+Access: Online.
+AC INI-Param: SS7_SNTIMERS_T8"
+ ::= {acSS7SignalingNodeTimersEntry 7}
+
+
+
+ acSS7SignalingNodeTimersT10 OBJECT-TYPE
+ SYNTAX Unsigned32 (500..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Waiting to repeat signalling route set test message.
+Access: Online.
+AC INI-Param: SS7_SNTIMERS_T10"
+ ::= {acSS7SignalingNodeTimersEntry 8}
+
+
+
+ acSS7SignalingNodeTimersT11 OBJECT-TYPE
+ SYNTAX Unsigned32 (500..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Transfer restricted timer.
+Access: Online.
+AC INI-Param: SS7_SNTIMERS_T11"
+ ::= {acSS7SignalingNodeTimersEntry 9}
+
+
+
+ acSS7SignalingNodeTimersT15 OBJECT-TYPE
+ SYNTAX Unsigned32 (500..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Waiting to start signalling route set congestion test.
+Access: Online.
+AC INI-Param: SS7_SNTIMERS_T15"
+ ::= {acSS7SignalingNodeTimersEntry 10}
+
+
+
+ acSS7SignalingNodeTimersT16 OBJECT-TYPE
+ SYNTAX Unsigned32 (500..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Waiting for route set congestion status update.
+Access: Online.
+AC INI-Param: SS7_SNTIMERS_T16"
+ ::= {acSS7SignalingNodeTimersEntry 11}
+
+
+
+ acSS7SignalingNodeTimersT18ITU OBJECT-TYPE
+ SYNTAX Unsigned32 (500..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Timer within a signalling point whose MTP restarts for supervising
+link and link set activation as well as the receipt of
+routing information.
+Access: Online.
+AC INI-Param: SS7_SNTIMERS_T18_ITU"
+ ::= {acSS7SignalingNodeTimersEntry 12}
+
+
+
+ acSS7SignalingNodeTimersT19ITU OBJECT-TYPE
+ SYNTAX Unsigned32 (500..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Supervision timer during MTP restart to avoid possible ping-pong
+of TFP, TFR and TRA messages.
+Access: Online.
+AC INI-Param: SS7_SNTIMERS_T19_ITU"
+ ::= {acSS7SignalingNodeTimersEntry 13}
+
+
+
+ acSS7SignalingNodeTimersT20ITU OBJECT-TYPE
+ SYNTAX Unsigned32 (500..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Overall MTP restart timer at the signalling point whose MTP
+restarts.
+Access: Online.
+AC INI-Param: SS7_SNTIMERS_T20_ITU"
+ ::= {acSS7SignalingNodeTimersEntry 14}
+
+
+
+ acSS7SignalingNodeTimersT21ITU OBJECT-TYPE
+ SYNTAX Unsigned32 (500..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Overall MTP restart timer at a signalling point adjacent to
+one whose MTP restarts.
+Access: Online.
+AC INI-Param: SS7_SNTIMERS_T21_ITU"
+ ::= {acSS7SignalingNodeTimersEntry 15}
+
+
+
+ acSS7SignalingNodeTimersT24ITU OBJECT-TYPE
+ SYNTAX Unsigned32 (500..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Stabilising timer after removal of local processor outage, used
+in LPO latching to RPO (national option).
+Access: Online.
+AC INI-Param: SS7_SNTIMERS_T24_ITU"
+ ::= {acSS7SignalingNodeTimersEntry 16}
+
+
+
+ acSS7SignalingNodeTimersT22ANSI OBJECT-TYPE
+ SYNTAX Unsigned32 (500..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Timer at restarting SP waiting for signalling links to bacome
+available.
+Access: Online.
+AC INI-Param: SS7_SNTIMERS_T22_ANSI"
+ ::= {acSS7SignalingNodeTimersEntry 17}
+
+
+
+ acSS7SignalingNodeTimersT23ANSI OBJECT-TYPE
+ SYNTAX Unsigned32 (500..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Timer at restarting SP, started after T22, waiting to receive
+all traffic restart allowed messages.
+Access: Online.
+AC INI-Param: SS7_SNTIMERS_T23_ANSI"
+ ::= {acSS7SignalingNodeTimersEntry 18}
+
+
+
+ acSS7SignalingNodeTimersT24ANSI OBJECT-TYPE
+ SYNTAX Unsigned32 (500..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Timer at restarting SP with transfer function, started after
+T23, waiting to broadcast all traffic restart allowed messages.
+Access: Online.
+AC INI-Param: SS7_SNTIMERS_T24_ANSI"
+ ::= {acSS7SignalingNodeTimersEntry 19}
+
+
+
+ acSS7SignalingNodeTimersT25ANSI OBJECT-TYPE
+ SYNTAX Unsigned32 (500..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Timer at SP adjacent to restarting SP waiting for traffic restart
+allowed message.
+Access: Online.
+AC INI-Param: SS7_SNTIMERS_T25_ANSI"
+ ::= {acSS7SignalingNodeTimersEntry 20}
+
+
+
+ acSS7SignalingNodeTimersT26ANSI OBJECT-TYPE
+ SYNTAX Unsigned32 (500..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Timer at restarting SP waiting to repeat traffic restart waiting
+message.
+Access: Online.
+AC INI-Param: SS7_SNTIMERS_T26_ANSI"
+ ::= {acSS7SignalingNodeTimersEntry 21}
+
+
+
+ acSS7SignalingNodeTimersT27ANSI OBJECT-TYPE
+ SYNTAX Unsigned32 (500..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This parameter is used to define the minimum duration of unavailability
+for a full restart.
+Access: Online.
+AC INI-Param: SS7_SNTIMERS_T27_ANSI"
+ ::= {acSS7SignalingNodeTimersEntry 22}
+
+
+
+ acSS7SignalingNodeTimersT28ANSI OBJECT-TYPE
+ SYNTAX Unsigned32 (500..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Timer at SP adjacent to restarting SP waiting for traffic restart
+waiting message.
+Access: Online.
+AC INI-Param: SS7_SNTIMERS_T28_ANSI"
+ ::= {acSS7SignalingNodeTimersEntry 23}
+
+
+
+ acSS7SignalingNodeTimersT29ANSI OBJECT-TYPE
+ SYNTAX Unsigned32 (500..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Timer started when TRA sent in response to unexpected TRA or
+TRW.
+Access: Online.
+AC INI-Param: SS7_SNTIMERS_T29_ANSI"
+ ::= {acSS7SignalingNodeTimersEntry 24}
+
+
+
+ acSS7SignalingNodeTimersT30ANSI OBJECT-TYPE
+ SYNTAX Unsigned32 (500..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Timer to limit sending of TFPs and TFRs in response to unexpected
+TRA or TRW.
+Access: Online.
+AC INI-Param: SS7_SNTIMERS_T30_ANSI"
+ ::= {acSS7SignalingNodeTimersEntry 25}
+
+
+
+ -- ****************************************
+ -- acSS7LinkSetTimers table declaration
+ -- ****************************************
+ acSS7LinkSetTimersTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcSS7LinkSetTimersEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ ::= {acSS7Timers 22}
+
+
+
+ -- ****************************************
+ -- acSS7LinkSetTimers table entry
+ -- ****************************************
+ acSS7LinkSetTimersEntry OBJECT-TYPE
+ SYNTAX AcSS7LinkSetTimersEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX {acSS7LinkSetTimersIndex}
+ ::= {acSS7LinkSetTimersTable 1}
+
+
+
+ -- ****************************************
+ -- acSS7LinkSetTimers TABLE
+ -- ****************************************
+ AcSS7LinkSetTimersEntry ::= SEQUENCE {
+ acSS7LinkSetTimersIndex Unsigned32,
+ acSS7LinkSetTimersIsUsed INTEGER,
+ acSS7LinkSetTimersAction INTEGER,
+ acSS7LinkSetTimersActionResult INTEGER,
+ acSS7LinkSetTimersName SnmpAdminString,
+ acSS7LinkSetTimersT1SLT Unsigned32,
+ acSS7LinkSetTimersT2SLT Unsigned32,
+ acSS7LinkSetTimersT1 Unsigned32,
+ acSS7LinkSetTimersT2 Unsigned32,
+ acSS7LinkSetTimersT3 Unsigned32,
+ acSS7LinkSetTimersT4 Unsigned32,
+ acSS7LinkSetTimersT5 Unsigned32,
+ acSS7LinkSetTimersT7 Unsigned32,
+ acSS7LinkSetTimersT12 Unsigned32,
+ acSS7LinkSetTimersT13 Unsigned32,
+ acSS7LinkSetTimersT14 Unsigned32,
+ acSS7LinkSetTimersT17 Unsigned32,
+ acSS7LinkSetTimersT20ANSI Unsigned32,
+ acSS7LinkSetTimersT21ANSI Unsigned32,
+ acSS7LinkSetTimersT22ITU Unsigned32,
+ acSS7LinkSetTimersT23ITU Unsigned32
+ }
+
+
+
+ acSS7LinkSetTimersIndex OBJECT-TYPE
+ SYNTAX Unsigned32 (0..4)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Index Field for line.
+AC INI-Param: acSS7LKSETTIMERS_PS_PARAMETER_INDEX"
+ ::= {acSS7LinkSetTimersEntry 1}
+
+
+
+ acSS7LinkSetTimersIsUsed OBJECT-TYPE
+ SYNTAX INTEGER {
+ no(0)
+,
+ yes(1)
+
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "
+AC INI-Param: N/A"
+ ::= {acSS7LinkSetTimersEntry 2}
+
+
+
+ acSS7LinkSetTimersAction OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(0)
+
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "management Field for ACTIONS.
+AC INI-Param: SS7_LKSETTIMERS_ACTION"
+ ::= {acSS7LinkSetTimersEntry 3}
+
+
+
+ acSS7LinkSetTimersActionResult OBJECT-TYPE
+ SYNTAX INTEGER {
+ succeeded(0)
+,
+ inProgress(1)
+,
+ failed(2)
+
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "management Field for ACTIONS RESULT.
+AC INI-Param: SS7_LKSETTIMERS_ACTION_RESULT"
+ ::= {acSS7LinkSetTimersEntry 4}
+
+
+
+ acSS7LinkSetTimersName OBJECT-TYPE
+ SYNTAX SnmpAdminString (SIZE (0..15))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "String name for Linkset timer-set.
+Access: Online.
+AC INI-Param: SS7_LKSETTIMERS_NAME"
+ ::= {acSS7LinkSetTimersEntry 5}
+
+
+
+ acSS7LinkSetTimersT1SLT OBJECT-TYPE
+ SYNTAX Unsigned32 (500..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Supervision timer for signalling link test acknowledgement message.
+Access: Online.
+AC INI-Param: SS7_LKSETTIMERS_T1SLT"
+ ::= {acSS7LinkSetTimersEntry 6}
+
+
+
+ acSS7LinkSetTimersT2SLT OBJECT-TYPE
+ SYNTAX Unsigned32 (500..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Interval timer for sending signalling link test messages.
+Access: Online.
+AC INI-Param: SS7_LKSETTIMERS_T2SLT"
+ ::= {acSS7LinkSetTimersEntry 7}
+
+
+
+ acSS7LinkSetTimersT1 OBJECT-TYPE
+ SYNTAX Unsigned32 (500..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Delay to avoid message mis-sequencing on changeover.
+Access: Online.
+AC INI-Param: SS7_LKSETTIMERS_T1"
+ ::= {acSS7LinkSetTimersEntry 8}
+
+
+
+ acSS7LinkSetTimersT2 OBJECT-TYPE
+ SYNTAX Unsigned32 (500..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Waiting for changeover acknowledgement.
+Access: Online.
+AC INI-Param: SS7_LKSETTIMERS_T2"
+ ::= {acSS7LinkSetTimersEntry 9}
+
+
+
+ acSS7LinkSetTimersT3 OBJECT-TYPE
+ SYNTAX Unsigned32 (500..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Time controlled diversion-delay to avoid mis-sequencing on changeback.
+Access: Online.
+AC INI-Param: SS7_LKSETTIMERS_T3"
+ ::= {acSS7LinkSetTimersEntry 10}
+
+
+
+ acSS7LinkSetTimersT4 OBJECT-TYPE
+ SYNTAX Unsigned32 (500..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Waiting for changeback acknowledgement (first attempt).
+Access: Online.
+AC INI-Param: SS7_LKSETTIMERS_T4"
+ ::= {acSS7LinkSetTimersEntry 11}
+
+
+
+ acSS7LinkSetTimersT5 OBJECT-TYPE
+ SYNTAX Unsigned32 (500..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Waiting for changeback acknowledgement (second attempt).
+Access: Online.
+AC INI-Param: SS7_LKSETTIMERS_T5"
+ ::= {acSS7LinkSetTimersEntry 12}
+
+
+
+ acSS7LinkSetTimersT7 OBJECT-TYPE
+ SYNTAX Unsigned32 (500..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Waiting for signalling data link connection acknowledgement.
+Access: Online.
+AC INI-Param: SS7_LKSETTIMERS_T7"
+ ::= {acSS7LinkSetTimersEntry 13}
+
+
+
+ acSS7LinkSetTimersT12 OBJECT-TYPE
+ SYNTAX Unsigned32 (500..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Waiting for uninhibit acknowledgement.
+Access: Online.
+AC INI-Param: SS7_LKSETTIMERS_T12"
+ ::= {acSS7LinkSetTimersEntry 14}
+
+
+
+ acSS7LinkSetTimersT13 OBJECT-TYPE
+ SYNTAX Unsigned32 (500..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Waiting for force uninhibit.
+Access: Online.
+AC INI-Param: SS7_LKSETTIMERS_T13"
+ ::= {acSS7LinkSetTimersEntry 15}
+
+
+
+ acSS7LinkSetTimersT14 OBJECT-TYPE
+ SYNTAX Unsigned32 (500..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Waiting for inhibition acknowledgement.
+Access: Online.
+AC INI-Param: SS7_LKSETTIMERS_T14"
+ ::= {acSS7LinkSetTimersEntry 16}
+
+
+
+ acSS7LinkSetTimersT17 OBJECT-TYPE
+ SYNTAX Unsigned32 (500..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Delay to avoid oscillation of initial alignment failure and
+link restart.
+Access: Online.
+AC INI-Param: SS7_LKSETTIMERS_T17"
+ ::= {acSS7LinkSetTimersEntry 17}
+
+
+
+ acSS7LinkSetTimersT20ANSI OBJECT-TYPE
+ SYNTAX Unsigned32 (500..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Local inhibit test timer.
+Access: Online.
+AC INI-Param: SS7_LKSETTIMERS_T20_ANSI"
+ ::= {acSS7LinkSetTimersEntry 18}
+
+
+
+ acSS7LinkSetTimersT21ANSI OBJECT-TYPE
+ SYNTAX Unsigned32 (500..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Remote inhibit test timer.
+Access: Online.
+AC INI-Param: SS7_LKSETTIMERS_T21_ANSI"
+ ::= {acSS7LinkSetTimersEntry 19}
+
+
+
+ acSS7LinkSetTimersT22ITU OBJECT-TYPE
+ SYNTAX Unsigned32 (500..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Local inhibit test timer.
+Access: Online.
+AC INI-Param: SS7_LKSETTIMERS_T22_ITU"
+ ::= {acSS7LinkSetTimersEntry 20}
+
+
+
+ acSS7LinkSetTimersT23ITU OBJECT-TYPE
+ SYNTAX Unsigned32 (500..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Remote inhibit test timer.
+Access: Online.
+AC INI-Param: SS7_LKSETTIMERS_T23_ITU"
+ ::= {acSS7LinkSetTimersEntry 21}
+
+
+
+ acSS7Links OBJECT IDENTIFIER ::= {acSS7Configuration 3}
+
+
+ -- ****************************************
+ -- acSS7LinkCommon table declaration
+ -- ****************************************
+ acSS7LinkCommonTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcSS7LinkCommonEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ ::= {acSS7Links 21}
+
+
+
+ -- ****************************************
+ -- acSS7LinkCommon table entry
+ -- ****************************************
+ acSS7LinkCommonEntry OBJECT-TYPE
+ SYNTAX AcSS7LinkCommonEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX {acSS7LinkCommonIndex}
+ ::= {acSS7LinkCommonTable 1}
+
+
+
+ -- ****************************************
+ -- acSS7LinkCommon TABLE
+ -- ****************************************
+ AcSS7LinkCommonEntry ::= SEQUENCE {
+ acSS7LinkCommonIndex Unsigned32,
+ acSS7LinkCommonRowStatus RowStatus,
+ acSS7LinkCommonAction INTEGER,
+ acSS7LinkCommonActionResult INTEGER,
+ acSS7LinkCommonName SnmpAdminString,
+ acSS7LinkCommonAdminState INTEGER,
+ acSS7LinkCommonOperState INTEGER,
+ acSS7LinkCommonTraceLevel INTEGER,
+ acSS7LinkCommonL2TypeSelector INTEGER,
+ acSS7LinkCommonL3TypeSelector INTEGER,
+ acSS7LinkCommonVariant INTEGER,
+ acSS7LinkCommonMtcBusy INTEGER,
+ acSS7LinkCommonRdcyBoardNum INTEGER,
+ acSS7LinkCommonMonSuFilterRequest INTEGER
+ }
+
+
+
+ acSS7LinkCommonIndex OBJECT-TYPE
+ SYNTAX Unsigned32 (0..63)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Index Field for line.
+AC INI-Param: MAX_SIGNALING_LINKS_PER_CARD"
+ ::= {acSS7LinkCommonEntry 1}
+
+
+
+ acSS7LinkCommonRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "ROWSTATUS Field for line.
+AC INI-Param: SS7_LINK_ROWSTATUS"
+ ::= {acSS7LinkCommonEntry 2}
+
+
+
+ acSS7LinkCommonAction OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(0)
+,
+ offLine(1)
+,
+ inService(2)
+,
+ activate(3)
+,
+ deActivate(4)
+,
+ inhibit(5)
+,
+ unInhibit(6)
+,
+ lpo(7)
+,
+ lpr(8)
+
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "management Field for ACTIONS.
+AC INI-Param: SS7_LINK_ACTION"
+ ::= {acSS7LinkCommonEntry 3}
+
+
+
+ acSS7LinkCommonActionResult OBJECT-TYPE
+ SYNTAX INTEGER {
+ succeeded(0)
+,
+ inProgress(1)
+,
+ failed(2)
+
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "management Field for ACTIONS RESULT.
+AC INI-Param: SS7_LINK_ACTION_RESULT"
+ ::= {acSS7LinkCommonEntry 4}
+
+
+
+ acSS7LinkCommonName OBJECT-TYPE
+ SYNTAX SnmpAdminString (SIZE (0..15))
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "String name for Link paramaters.
+Access: Online.
+AC INI-Param: SS7_LINK_NAME"
+ ::= {acSS7LinkCommonEntry 5}
+
+
+
+ acSS7LinkCommonAdminState OBJECT-TYPE
+ SYNTAX INTEGER {
+ offLine(0)
+,
+ inService(2)
+
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Administrative state of singnalling link.
+AC INI-Param: SS7_LINK_ADMINISTRATIVE_STATE"
+ ::= {acSS7LinkCommonEntry 6}
+
+
+
+ acSS7LinkCommonOperState OBJECT-TYPE
+ SYNTAX INTEGER {
+ offLine(0)
+,
+ busy(1)
+,
+ inService(2)
+
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Operational state of singnalling link.
+AC INI-Param: SS7_LINK_OPERATIONAL_STATE"
+ ::= {acSS7LinkCommonEntry 7}
+
+
+
+ acSS7LinkCommonTraceLevel OBJECT-TYPE
+ SYNTAX INTEGER {
+ traceLevel0(0)
+,
+ traceLevel1(1)
+
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Trace level of singnalling link (level 2).
+Access: Online.
+AC INI-Param: SS7_LINK_TRACE_LEVEL"
+ ::= {acSS7LinkCommonEntry 8}
+
+
+
+ acSS7LinkCommonL2TypeSelector OBJECT-TYPE
+ SYNTAX INTEGER {
+ nonetype-L2(0)
+,
+ mtp2(1)
+,
+ m2ua-mgc(2)
+,
+ ss7monitoring(4)
+
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Link layer 2 type - defines level 2 media of signaling link.
+Access: Online.
+AC INI-Param: SS7_LINK_L2_TYPE"
+ ::= {acSS7LinkCommonEntry 9}
+
+
+
+ acSS7LinkCommonL3TypeSelector OBJECT-TYPE
+ SYNTAX INTEGER {
+ nonetype-L3(0)
+,
+ m2ua-sg(1)
+,
+ mtp3(2)
+,
+ mtp2-tunneling(3)
+,
+ mtp2OverIP(4)
+,
+ ss7monitoring(5)
+
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Link high layer type - defines level 3 or L2 high layer of signalling
+link.
+Access: Online.
+AC INI-Param: SS7_LINK_L3_TYPE"
+ ::= {acSS7LinkCommonEntry 10}
+
+
+
+ acSS7LinkCommonVariant OBJECT-TYPE
+ SYNTAX INTEGER {
+ itu(1)
+,
+ ansi(2)
+,
+ china(3)
+
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Variant (layer 2) of singnalling link (TDM).
+Access: Online.
+AC INI-Param: SS7_LINK_LAYER2_VARIANT"
+ ::= {acSS7LinkCommonEntry 11}
+
+
+
+ acSS7LinkCommonMtcBusy OBJECT-TYPE
+ SYNTAX INTEGER {
+ no(0)
+,
+ yes(1)
+
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Link local busy indicator - if set, indicates link is busy due
+to local mtc action.
+AC INI-Param: SS7_LINK_MTC_BUSY"
+ ::= {acSS7LinkCommonEntry 12}
+
+
+
+ acSS7LinkCommonRdcyBoardNum OBJECT-TYPE
+ SYNTAX INTEGER {
+ rdcyBoardNum0(0)
+,
+ rdcyBoardNum1(1)
+,
+ rdcyBoardNum2(2)
+
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Board number in which the link is physically connected.
+Access: Online.
+AC INI-Param: SS7_LINK_RDCY_BOARD"
+ ::= {acSS7LinkCommonEntry 13}
+
+
+
+ acSS7LinkCommonMonSuFilterRequest OBJECT-TYPE
+ SYNTAX INTEGER {
+ filterAll(0)
+,
+ filterLSSUandFISU(1)
+,
+ filterFISU(2)
+,
+ noFilter(3)
+
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "SS7 Monitoring link SU filter- Defines the type of SU message
+to filter. 0: Filter all types of SU messages
+1: Filter LSSU and FISU messages
+2: Filter only FISU messages
+3: Do not filter any message.
+Access: Online.
+AC INI-Param: SS7_LINK_MON_SU_FILTER"
+ ::= {acSS7LinkCommonEntry 14}
+
+
+
+ -- ****************************************
+ -- acSS7LinkTDM table declaration
+ -- ****************************************
+ acSS7LinkTDMTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcSS7LinkTDMEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ ::= {acSS7Links 22}
+
+
+
+ -- ****************************************
+ -- acSS7LinkTDM table entry
+ -- ****************************************
+ acSS7LinkTDMEntry OBJECT-TYPE
+ SYNTAX AcSS7LinkTDMEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX {acSS7LinkCommonIndex}
+ ::= {acSS7LinkTDMTable 1}
+
+
+
+ -- ****************************************
+ -- acSS7LinkTDM TABLE
+ -- ****************************************
+ AcSS7LinkTDMEntry ::= SEQUENCE {
+ acSS7LinkTDMTrunkNumber Integer32,
+ acSS7LinkTDMTimeSlotNumber Unsigned32,
+ acSS7LinkTDMInhibit INTEGER,
+ acSS7LinkTDMMtp2Atts INTEGER,
+ acSS7LinkTDMCongestionLowMark Unsigned32,
+ acSS7LinkTDMCongestionHighMark Unsigned32,
+ acSS7LinkTDMBlock INTEGER
+ }
+
+
+
+ acSS7LinkTDMTrunkNumber OBJECT-TYPE
+ SYNTAX Integer32 (-1..84)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Trunk number of singnalling link (TDM).
+Access: Online.
+AC INI-Param: SS7_LINK_TRUNK_NUMBER"
+ ::= {acSS7LinkTDMEntry 1}
+
+
+
+ acSS7LinkTDMTimeSlotNumber OBJECT-TYPE
+ SYNTAX Unsigned32 (1..31)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Time-Slot number of singnalling link (TDM).
+Access: Online.
+AC INI-Param: SS7_LINK_TIMESLOT_NUMBER"
+ ::= {acSS7LinkTDMEntry 2}
+
+
+
+ acSS7LinkTDMInhibit OBJECT-TYPE
+ SYNTAX INTEGER {
+ unInhibited(0)
+,
+ inhibited(1)
+
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Link inhibit indicator - if set, indicates link is inhibited..
+AC INI-Param: SS7_LINK_INHIBITION"
+ ::= {acSS7LinkTDMEntry 3}
+
+
+
+ acSS7LinkTDMMtp2Atts OBJECT-TYPE
+ SYNTAX INTEGER {
+ mtp2Atts0(0)
+,
+ mtp2Atts1(1)
+,
+ mtp2Atts2(2)
+,
+ mtp2Atts3(3)
+
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "MTP2 attributes of singnalling link (TDM).
+Access: Online.
+AC INI-Param: SS7_LINK_MTP2_ATTRIBUTES"
+ ::= {acSS7LinkTDMEntry 4}
+
+
+
+ acSS7LinkTDMCongestionLowMark OBJECT-TYPE
+ SYNTAX Unsigned32 (0..255)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Link congestion low mark of signalling link (TDM).
+Access: Online.
+AC INI-Param: SS7_CONGESTION_LOW_MARK"
+ ::= {acSS7LinkTDMEntry 5}
+
+
+
+ acSS7LinkTDMCongestionHighMark OBJECT-TYPE
+ SYNTAX Unsigned32 (0..255)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Link congestion high mark of signalling link (TDM).
+Access: Online.
+AC INI-Param: SS7_CONGESTION_HIGH_MARK"
+ ::= {acSS7LinkTDMEntry 6}
+
+
+
+ acSS7LinkTDMBlock OBJECT-TYPE
+ SYNTAX INTEGER {
+ l3linkunblocked(0)
+,
+ l3linklocalblocked(1)
+,
+ l3linkremoteblockde(2)
+,
+ l3linklocalandremotelocked(3)
+
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Link blocked indicator.
+AC INI-Param: SS7_LINK_BLOCKED"
+ ::= {acSS7LinkTDMEntry 7}
+
+
+
+ -- ****************************************
+ -- acSS7LinkSigTran table declaration
+ -- ****************************************
+ acSS7LinkSigTranTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcSS7LinkSigTranEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ ::= {acSS7Links 23}
+
+
+
+ -- ****************************************
+ -- acSS7LinkSigTran table entry
+ -- ****************************************
+ acSS7LinkSigTranEntry OBJECT-TYPE
+ SYNTAX AcSS7LinkSigTranEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX {acSS7LinkCommonIndex}
+ ::= {acSS7LinkSigTranTable 1}
+
+
+
+ -- ****************************************
+ -- acSS7LinkSigTran TABLE
+ -- ****************************************
+ AcSS7LinkSigTranEntry ::= SEQUENCE {
+ acSS7LinkSigTranGroupId Integer32,
+ acSS7LinkSigTranIfid Integer32
+ }
+
+
+
+ acSS7LinkSigTranGroupId OBJECT-TYPE
+ SYNTAX Integer32 (-1..65534)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Group ID (M2UA) of signaling link.
+Access: Online.
+AC INI-Param: SS7_LINK_GROUP_ID"
+ ::= {acSS7LinkSigTranEntry 1}
+
+
+
+ acSS7LinkSigTranIfid OBJECT-TYPE
+ SYNTAX Integer32 (-1..2147483647)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Interface ID (M2UA) of singnalling link.
+Access: Online.
+AC INI-Param: SS7_LINK_M2UA_IF_ID"
+ ::= {acSS7LinkSigTranEntry 2}
+
+
+
+ -- ****************************************
+ -- acSS7LinkATM table declaration
+ -- ****************************************
+ acSS7LinkATMTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcSS7LinkATMEntry
+ MAX-ACCESS not-accessible
+ STATUS obsolete
+ DESCRIPTION
+ ""
+ ::= {acSS7Links 24}
+
+
+
+ -- ****************************************
+ -- acSS7LinkATM table entry
+ -- ****************************************
+ acSS7LinkATMEntry OBJECT-TYPE
+ SYNTAX AcSS7LinkATMEntry
+ MAX-ACCESS not-accessible
+ STATUS obsolete
+ DESCRIPTION
+ ""
+ INDEX {acSS7LinkCommonIndex}
+ ::= {acSS7LinkATMTable 1}
+
+
+
+ -- ****************************************
+ -- acSS7LinkATM TABLE
+ -- ****************************************
+ AcSS7LinkATMEntry ::= SEQUENCE {
+ acSS7LinkATMSAALLinkProfileNum Unsigned32,
+ acSS7LinkATMSAALLinkType INTEGER,
+ acSS7LinkATMSAALLinkInterfaceNum Unsigned32,
+ acSS7LinkATMSAALLinkVPI Unsigned32,
+ acSS7LinkATMSAALLinkVCI Unsigned32
+ }
+
+
+
+ acSS7LinkATMSAALLinkProfileNum OBJECT-TYPE
+ SYNTAX Unsigned32 (0..128)
+ MAX-ACCESS read-create
+ STATUS obsolete
+ DESCRIPTION
+ "ATM SAAL Link profile number.
+Access: Online.
+AC INI-Param: ATM_SAAL_LINK_PROFILE_NUM"
+ ::= {acSS7LinkATMEntry 1}
+
+
+
+ acSS7LinkATMSAALLinkType OBJECT-TYPE
+ SYNTAX INTEGER {
+ aTM-VCC-Type-PVC(0)
+,
+ aTM-VCC-Type-SVC(1)
+
+ }
+ MAX-ACCESS read-create
+ STATUS obsolete
+ DESCRIPTION
+ "ATM SAAL link Type PVC/SVC.
+Access: Online.
+AC INI-Param: ATM_SAAL_LINK_TYPE"
+ ::= {acSS7LinkATMEntry 2}
+
+
+
+ acSS7LinkATMSAALLinkInterfaceNum OBJECT-TYPE
+ SYNTAX Unsigned32 (0..128)
+ MAX-ACCESS read-create
+ STATUS obsolete
+ DESCRIPTION
+ "ATM SAAL link port num.
+Access: Online.
+AC INI-Param: ATM_SAAL_LINK_PORT_NUM"
+ ::= {acSS7LinkATMEntry 3}
+
+
+
+ acSS7LinkATMSAALLinkVPI OBJECT-TYPE
+ SYNTAX Unsigned32 (0..255)
+ MAX-ACCESS read-create
+ STATUS obsolete
+ DESCRIPTION
+ "ATM SAAL link VPI.
+Access: Online.
+AC INI-Param: ATM_SAAL_LINK_VPI"
+ ::= {acSS7LinkATMEntry 4}
+
+
+
+ acSS7LinkATMSAALLinkVCI OBJECT-TYPE
+ SYNTAX Unsigned32 (0..65536)
+ MAX-ACCESS read-create
+ STATUS obsolete
+ DESCRIPTION
+ "ATM SAAL link VCI.
+Access: Online.
+AC INI-Param: ATM_SAAL_LINK_VCI"
+ ::= {acSS7LinkATMEntry 5}
+
+
+
+ -- ****************************************
+ -- acSS7LinkTNL table declaration
+ -- ****************************************
+ acSS7LinkTNLTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcSS7LinkTNLEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ ::= {acSS7Links 25}
+
+
+
+ -- ****************************************
+ -- acSS7LinkTNL table entry
+ -- ****************************************
+ acSS7LinkTNLEntry OBJECT-TYPE
+ SYNTAX AcSS7LinkTNLEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX {acSS7LinkCommonIndex}
+ ::= {acSS7LinkTNLTable 1}
+
+
+
+ -- ****************************************
+ -- acSS7LinkTNL TABLE
+ -- ****************************************
+ AcSS7LinkTNLEntry ::= SEQUENCE {
+ acSS7LinkTNLOtherSideLinkNum Unsigned32,
+ acSS7LinkTNLAlignmentMode INTEGER,
+ acSS7LinkTNLCongestionMode INTEGER,
+ acSS7LinkTNLWaitStartCompTimer Unsigned32,
+ acSS7LinkTNLOosStartDelayTimer Unsigned32,
+ acSS7LinkTNLWaitOtherSideInsvTimer Unsigned32
+ }
+
+
+
+ acSS7LinkTNLOtherSideLinkNum OBJECT-TYPE
+ SYNTAX Unsigned32 (0..128)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "MTP2 Tunneling: MGC link number (MTP2 'other side' of signaling
+link).
+Access: Online.
+AC INI-Param: SS7_LINK_TNL_MGC_LINK_NUMBER"
+ ::= {acSS7LinkTNLEntry 1}
+
+
+
+ acSS7LinkTNLAlignmentMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal(0)
+,
+ emergency(1)
+
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "MTP2 Tunneling: Alignment mode of signalling links in tunnel.
+Access: Online.
+AC INI-Param: SS7_LINK_TNL_ALIGNMENT_MODE"
+ ::= {acSS7LinkTNLEntry 2}
+
+
+
+ acSS7LinkTNLCongestionMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ accept(0)
+,
+ discard(1)
+
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "MTP2 Tunneling: Congestion mode of signalling links in tunnel.
+Access: Online.
+AC INI-Param: SS7_LINK_TNL_CONGESTION_MODE"
+ ::= {acSS7LinkTNLEntry 3}
+
+
+
+ acSS7LinkTNLWaitStartCompTimer OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2147483647)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "MTP2 Tunneling: wait start complete timer.
+Access: Online.
+AC INI-Param: SS7_LINK_TNL_WAIT_START_COMPLETE_TIMER"
+ ::= {acSS7LinkTNLEntry 4}
+
+
+
+ acSS7LinkTNLOosStartDelayTimer OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2147483647)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "MTP2 Tunneling: OOS start delay timer.
+Access: Online.
+AC INI-Param: SS7_LINK_TNL_OOS_START_DELAY_TIMER"
+ ::= {acSS7LinkTNLEntry 5}
+
+
+
+ acSS7LinkTNLWaitOtherSideInsvTimer OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2147483647)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "MTP2 Tunneling: wait for other side to be in service timer.
+Access: Online.
+AC INI-Param: SS7_LINK_TNL_WAIT_OTHER_SIDE_INSV_TIMER"
+ ::= {acSS7LinkTNLEntry 6}
+
+
+
+ acSS7Nodes OBJECT IDENTIFIER ::= {acSS7Configuration 4}
+
+
+ -- ****************************************
+ -- acSS7SignalingNode table declaration
+ -- ****************************************
+ acSS7SignalingNodeTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcSS7SignalingNodeEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ ::= {acSS7Nodes 21}
+
+
+
+ -- ****************************************
+ -- acSS7SignalingNode table entry
+ -- ****************************************
+ acSS7SignalingNodeEntry OBJECT-TYPE
+ SYNTAX AcSS7SignalingNodeEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX {acSS7SignalingNodeIndex}
+ ::= {acSS7SignalingNodeTable 1}
+
+
+
+ -- ****************************************
+ -- acSS7SignalingNode TABLE
+ -- ****************************************
+ AcSS7SignalingNodeEntry ::= SEQUENCE {
+ acSS7SignalingNodeIndex Unsigned32,
+ acSS7SignalingNodeRowStatus RowStatus,
+ acSS7SignalingNodeAction INTEGER,
+ acSS7SignalingNodeActionResult INTEGER,
+ acSS7SignalingNodeName SnmpAdminString,
+ acSS7SignalingNodeTraceLevel INTEGER,
+ acSS7SignalingNodeAdminState INTEGER,
+ acSS7SignalingNodeOperState INTEGER,
+ acSS7SignalingNodeMtcBusy INTEGER,
+ acSS7SignalingNodeVariant INTEGER,
+ acSS7SignalingNodeNwIndicator INTEGER,
+ acSS7SignalingNodeSpStp INTEGER,
+ acSS7SignalingNodeTfc INTEGER,
+ acSS7SignalingNodeOpc Unsigned32,
+ acSS7SignalingNodeRouteSetCongestionWindow Unsigned32,
+ acSS7SignalingNodeTimersIdx INTEGER,
+ acSS7SignalingNodeIsupApp INTEGER,
+ acSS7SignalingNodeSccpApp INTEGER,
+ acSS7SignalingNodeBisupApp INTEGER,
+ acSS7SignalingNodeAlcapApp INTEGER,
+ acSS7SignalingNodeRdcyOpc Unsigned32,
+ acSS7SignalingNodeTupApp INTEGER,
+ acSS7SignalingNodeBiccApp INTEGER
+ }
+
+
+
+ acSS7SignalingNodeIndex OBJECT-TYPE
+ SYNTAX Unsigned32 (0..1)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "
+AC INI-Param: SS7_SN_INDEX"
+ ::= {acSS7SignalingNodeEntry 1}
+
+
+
+ acSS7SignalingNodeRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "ROWSTATUS Field for line.
+AC INI-Param: SS7_SN_ROWSTATUS"
+ ::= {acSS7SignalingNodeEntry 2}
+
+
+
+ acSS7SignalingNodeAction OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(0)
+,
+ stop(1)
+,
+ start(2)
+,
+ inService(3)
+,
+ offLine(4)
+
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "management Field for ACTIONS.
+AC INI-Param: SS7_SN_ACTION"
+ ::= {acSS7SignalingNodeEntry 3}
+
+
+
+ acSS7SignalingNodeActionResult OBJECT-TYPE
+ SYNTAX INTEGER {
+ succeeded(0)
+,
+ inProgress(1)
+,
+ failed(2)
+
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "management Field for ACTIONS RESULT.
+AC INI-Param: SS7_SN_ACTION_RESULT"
+ ::= {acSS7SignalingNodeEntry 4}
+
+
+
+ acSS7SignalingNodeName OBJECT-TYPE
+ SYNTAX SnmpAdminString (SIZE (0..15))
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "String name for SN Params.
+Access: Online.
+AC INI-Param: SS7_SN_NAME"
+ ::= {acSS7SignalingNodeEntry 5}
+
+
+
+ acSS7SignalingNodeTraceLevel OBJECT-TYPE
+ SYNTAX INTEGER {
+ traceLevel0(0)
+,
+ traceLevel1(1)
+
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Trace level of singnalling node (level 3).
+Access: Online.
+AC INI-Param: SS7_SN_TRACE_LEVEL"
+ ::= {acSS7SignalingNodeEntry 6}
+
+
+
+ acSS7SignalingNodeAdminState OBJECT-TYPE
+ SYNTAX INTEGER {
+ offLine(0)
+,
+ inService(2)
+
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Administrative state of singnalling node.
+AC INI-Param: SS7_SN_ADMINISTRATIVE_STATE"
+ ::= {acSS7SignalingNodeEntry 7}
+
+
+
+ acSS7SignalingNodeOperState OBJECT-TYPE
+ SYNTAX INTEGER {
+ offLine(0)
+,
+ busy(1)
+,
+ inService(2)
+
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Operational state of singnalling node.
+AC INI-Param: SS7_SN_OPERATIONAL_STATE"
+ ::= {acSS7SignalingNodeEntry 8}
+
+
+
+ acSS7SignalingNodeMtcBusy OBJECT-TYPE
+ SYNTAX INTEGER {
+ no(0)
+,
+ yes(1)
+
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Manual busy status of singnalling node.
+AC INI-Param: SS7_SN_MTC_BUSY_STATUS"
+ ::= {acSS7SignalingNodeEntry 9}
+
+
+
+ acSS7SignalingNodeVariant OBJECT-TYPE
+ SYNTAX INTEGER {
+ itu(1)
+,
+ ansi(2)
+,
+ china(3)
+
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Variant of singnalling node.
+Access: Online.
+AC INI-Param: SS7_SN_VARIANT"
+ ::= {acSS7SignalingNodeEntry 10}
+
+
+
+ acSS7SignalingNodeNwIndicator OBJECT-TYPE
+ SYNTAX INTEGER {
+ international(0)
+,
+ internationalSpare(1)
+,
+ national(2)
+,
+ nationalSpare(3)
+
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Network Indicator of singnalling node.
+Access: Online.
+AC INI-Param: SS7_SN_NI"
+ ::= {acSS7SignalingNodeEntry 11}
+
+
+
+ acSS7SignalingNodeSpStp OBJECT-TYPE
+ SYNTAX INTEGER {
+ sp(0)
+,
+ stp(1)
+
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Routing function of singnalling node.
+Access: Online.
+AC INI-Param: SS7_SN_SP_STP"
+ ::= {acSS7SignalingNodeEntry 12}
+
+
+
+ acSS7SignalingNodeTfc OBJECT-TYPE
+ SYNTAX INTEGER {
+ no(0)
+,
+ yes(1)
+
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "TFC function of singnalling node.
+Access: Online.
+AC INI-Param: SS7_SN_TFC"
+ ::= {acSS7SignalingNodeEntry 13}
+
+
+
+ acSS7SignalingNodeOpc OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2147483647)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Origination (local) point-code of singnalling node.
+Access: Online.
+AC INI-Param: SS7_SN_OPC"
+ ::= {acSS7SignalingNodeEntry 14}
+
+
+
+ acSS7SignalingNodeRouteSetCongestionWindow OBJECT-TYPE
+ SYNTAX Unsigned32 (0..255)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Routeset Congestion Size (messages) of singnalling node.
+Access: Online.
+AC INI-Param: SS7_SN_ROUTESET_CONGESTION_WINSIZE"
+ ::= {acSS7SignalingNodeEntry 15}
+
+
+
+ acSS7SignalingNodeTimersIdx OBJECT-TYPE
+ SYNTAX INTEGER {
+ timersIdx0(0)
+,
+ timersIdx1(1)
+,
+ timersIdx2(2)
+,
+ timersIdx3(3)
+,
+ timersIdx4(4)
+
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Index of SNTimers table used for this signaling node.
+Access: Online.
+AC INI-Param: SS7_SN_TIMERS_INDEX"
+ ::= {acSS7SignalingNodeEntry 16}
+
+
+
+ acSS7SignalingNodeIsupApp OBJECT-TYPE
+ SYNTAX INTEGER {
+ nill(0)
+,
+ ual(4)
+,
+ l4Gen(7)
+
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Level 4 application that handles ISUP traffic for this singnalling
+node.
+Access: Online.
+AC INI-Param: SS7_SN_ISUP_APP"
+ ::= {acSS7SignalingNodeEntry 17}
+
+
+
+ acSS7SignalingNodeSccpApp OBJECT-TYPE
+ SYNTAX INTEGER {
+ nill(0)
+,
+ ual(4)
+,
+ l4Gen(7)
+
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Level 4 application that handles SCCP traffic for this singnalling
+node.
+Access: Online.
+AC INI-Param: SS7_SN_SCCP_APP"
+ ::= {acSS7SignalingNodeEntry 18}
+
+
+
+ acSS7SignalingNodeBisupApp OBJECT-TYPE
+ SYNTAX INTEGER {
+ nill(0)
+,
+ ual(4)
+,
+ l4Gen(7)
+
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Level 4 application that handles BISUP traffic for this singnalling
+node.
+Access: Online.
+AC INI-Param: SS7_SN_BISUP_APP"
+ ::= {acSS7SignalingNodeEntry 19}
+
+
+
+ acSS7SignalingNodeAlcapApp OBJECT-TYPE
+ SYNTAX INTEGER {
+ nill(0)
+,
+ ual(4)
+,
+ alcap(5)
+,
+ l4Gen(7)
+
+ }
+ MAX-ACCESS read-create
+ STATUS deprecated
+ DESCRIPTION
+ "Level 4 application that handles ALCAP traffic for this singnalling
+node.
+Access: Online.
+AC INI-Param: SS7_SN_ALCAP_APP"
+ ::= {acSS7SignalingNodeEntry 20}
+
+
+
+ acSS7SignalingNodeRdcyOpc OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Internal point-code of singnalling node - in case of SS7 shared
+point code.
+AC INI-Param: SS7_SN_RDCY_OPC"
+ ::= {acSS7SignalingNodeEntry 21}
+
+
+
+ acSS7SignalingNodeTupApp OBJECT-TYPE
+ SYNTAX INTEGER {
+ nill(0)
+,
+ ual(4)
+,
+ l4Gen(7)
+
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Level 4 application that handles TUP traffic for this signaling
+node.
+Access: Online.
+AC INI-Param: SS7_SN_TUP_APP"
+ ::= {acSS7SignalingNodeEntry 22}
+
+
+
+ acSS7SignalingNodeBiccApp OBJECT-TYPE
+ SYNTAX INTEGER {
+ nil(0)
+,
+ ual(4)
+
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Level 4 application that handles BICC traffic for this signaling
+node.
+Access: Online.
+AC INI-Param: SS7_SN_BICC_APP"
+ ::= {acSS7SignalingNodeEntry 23}
+
+
+
+ acSS7LinkSets OBJECT IDENTIFIER ::= {acSS7Nodes 31}
+
+
+ -- ****************************************
+ -- acSS7LinkSet table declaration
+ -- ****************************************
+ acSS7LinkSetTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcSS7LinkSetEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ ::= {acSS7LinkSets 21}
+
+
+
+ -- ****************************************
+ -- acSS7LinkSet table entry
+ -- ****************************************
+ acSS7LinkSetEntry OBJECT-TYPE
+ SYNTAX AcSS7LinkSetEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX {acSS7LinkSetSNIndex,acSS7LinkSetLksetIndex}
+ ::= {acSS7LinkSetTable 1}
+
+
+
+ -- ****************************************
+ -- acSS7LinkSet TABLE
+ -- ****************************************
+ AcSS7LinkSetEntry ::= SEQUENCE {
+ acSS7LinkSetSNIndex Unsigned32,
+ acSS7LinkSetLksetIndex Unsigned32,
+ acSS7LinkSetRowStatus RowStatus,
+ acSS7LinkSetAction INTEGER,
+ acSS7LinkSetActionResult INTEGER,
+ acSS7LinkSetName SnmpAdminString,
+ acSS7LinkSetAdminState INTEGER,
+ acSS7LinkSetOperState INTEGER,
+ acSS7LinkSetMtcBusyState INTEGER,
+ acSS7LinkSetDPC Unsigned32,
+ acSS7LinkSetLinksMask Unsigned32,
+ acSS7LinkSetLinksAltMask Unsigned32,
+ acSS7LinkSetTimersIdx INTEGER
+ }
+
+
+
+ acSS7LinkSetSNIndex OBJECT-TYPE
+ SYNTAX Unsigned32 (0..1)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "First Index Field for line.
+AC INI-Param: SS7_LINKSET_SN_INDEX"
+ ::= {acSS7LinkSetEntry 1}
+
+
+
+ acSS7LinkSetLksetIndex OBJECT-TYPE
+ SYNTAX Unsigned32 (0..31)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Second Index Field for line.
+AC INI-Param: SS7_LINKSET_LINKSET_INDEX"
+ ::= {acSS7LinkSetEntry 2}
+
+
+
+ acSS7LinkSetRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "ROWSTATUS Field for line.
+AC INI-Param: SS7_LINKSET_ROWSTATUS"
+ ::= {acSS7LinkSetEntry 3}
+
+
+
+ acSS7LinkSetAction OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(0)
+,
+ offLine(1)
+,
+ inService(2)
+,
+ activate(3)
+,
+ deActivate(4)
+
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "management Field for ACTIONS.
+AC INI-Param: SS7_LINKSET_ACTION"
+ ::= {acSS7LinkSetEntry 4}
+
+
+
+ acSS7LinkSetActionResult OBJECT-TYPE
+ SYNTAX INTEGER {
+ succeeded(0)
+,
+ inProgress(1)
+,
+ failed(2)
+
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "management Field for ACTIONS RESULT.
+AC INI-Param: SS7_SN_ACTION_RESULT"
+ ::= {acSS7LinkSetEntry 5}
+
+
+
+ acSS7LinkSetName OBJECT-TYPE
+ SYNTAX SnmpAdminString (SIZE (0..15))
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "String name for LINKSET Params.
+Access: Online.
+AC INI-Param: SS7_LINKSET_NAME"
+ ::= {acSS7LinkSetEntry 6}
+
+
+
+ acSS7LinkSetAdminState OBJECT-TYPE
+ SYNTAX INTEGER {
+ offLine(0)
+,
+ inService(2)
+
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Administrative state of singnalling linkset.
+AC INI-Param: SS7_LINKSET_ADMINISTRATIVE_STATE"
+ ::= {acSS7LinkSetEntry 7}
+
+
+
+ acSS7LinkSetOperState OBJECT-TYPE
+ SYNTAX INTEGER {
+ offLine(0)
+,
+ busy(1)
+,
+ inService(2)
+
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Operational state of singnalling linkset.
+AC INI-Param: SS7_LINKSET_OPERATIONAL_STATE"
+ ::= {acSS7LinkSetEntry 8}
+
+
+
+ acSS7LinkSetMtcBusyState OBJECT-TYPE
+ SYNTAX INTEGER {
+ no(0)
+,
+ yes(1)
+
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Manual busy status of singnalling linkset.
+AC INI-Param: SS7_LINKSET_MTC_BUSY_STATUS"
+ ::= {acSS7LinkSetEntry 9}
+
+
+
+ acSS7LinkSetDPC OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2147483647)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Destination Point-Code of singnalling linkset.
+Access: Online.
+AC INI-Param: SS7_LINKSET_DPC"
+ ::= {acSS7LinkSetEntry 10}
+
+
+
+ acSS7LinkSetLinksMask OBJECT-TYPE
+ SYNTAX Unsigned32 (0..255)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Mask for links within singnalling linkset.
+Access: Online.
+AC INI-Param: SS7_LINKSET_MASK"
+ ::= {acSS7LinkSetEntry 11}
+
+
+
+ acSS7LinkSetLinksAltMask OBJECT-TYPE
+ SYNTAX Unsigned32 (0..255)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Alternate mask for links within singnalling linkset.
+Access: Online.
+AC INI-Param: SS7_LINKSET_ALTERNATE_MASK"
+ ::= {acSS7LinkSetEntry 12}
+
+
+
+ acSS7LinkSetTimersIdx OBJECT-TYPE
+ SYNTAX INTEGER {
+ timersIdx0(0)
+,
+ timersIdx1(1)
+,
+ timersIdx2(2)
+,
+ timersIdx3(3)
+,
+ timersIdx4(4)
+
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Timers Index of singnalling linkset.
+Access: Online.
+AC INI-Param: SS7_LINKSET_TIMERS_INDEX"
+ ::= {acSS7LinkSetEntry 13}
+
+
+
+ -- ****************************************
+ -- acSS7LinkSetLink table declaration
+ -- ****************************************
+ acSS7LinkSetLinkTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcSS7LinkSetLinkEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ ::= {acSS7LinkSets 22}
+
+
+
+ -- ****************************************
+ -- acSS7LinkSetLink table entry
+ -- ****************************************
+ acSS7LinkSetLinkEntry OBJECT-TYPE
+ SYNTAX AcSS7LinkSetLinkEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX {acSS7LinkSetLinkSNIndex,acSS7LinkSetLinkLinksetIndex,acSS7LinkSetLinkInnerLinkIndex}
+ ::= {acSS7LinkSetLinkTable 1}
+
+
+
+ -- ****************************************
+ -- acSS7LinkSetLink TABLE
+ -- ****************************************
+ AcSS7LinkSetLinkEntry ::= SEQUENCE {
+ acSS7LinkSetLinkSNIndex Unsigned32,
+ acSS7LinkSetLinkLinksetIndex Unsigned32,
+ acSS7LinkSetLinkInnerLinkIndex Unsigned32,
+ acSS7LinkSetLinkRowStatus RowStatus,
+ acSS7LinkSetLinkAction INTEGER,
+ acSS7LinkSetLinkActionResult INTEGER,
+ acSS7LinkSetLinkLinkNo Unsigned32,
+ acSS7LinkSetLinkLinkSlc Unsigned32
+ }
+
+
+
+ acSS7LinkSetLinkSNIndex OBJECT-TYPE
+ SYNTAX Unsigned32 (0..1)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "First Index Field for line: Signalling Node Number.
+AC INI-Param: SS7_LINKSETLINK_SN_INDEX"
+ ::= {acSS7LinkSetLinkEntry 1}
+
+
+
+ acSS7LinkSetLinkLinksetIndex OBJECT-TYPE
+ SYNTAX Unsigned32 (0..31)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Second Index Field for line: Signalling Linkset Number.
+AC INI-Param: SS7_LINKSETLINK_LINKSET_INDEX"
+ ::= {acSS7LinkSetLinkEntry 2}
+
+
+
+ acSS7LinkSetLinkInnerLinkIndex OBJECT-TYPE
+ SYNTAX Unsigned32 (0..7)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Third Index Field for line: Inner Link Index in Signalling Linkset.
+AC INI-Param: SS7_LINKSETLINK_INNER_LINK_INDEX"
+ ::= {acSS7LinkSetLinkEntry 3}
+
+
+
+ acSS7LinkSetLinkRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "ROWSTATUS Field for line.
+AC INI-Param: SS7_LINKSETLINK_ROWSTATUS"
+ ::= {acSS7LinkSetLinkEntry 4}
+
+
+
+ acSS7LinkSetLinkAction OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(0)
+
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "management Field for ACTIONS.
+AC INI-Param: SS7_LINKSETLINK_ACTION"
+ ::= {acSS7LinkSetLinkEntry 5}
+
+
+
+ acSS7LinkSetLinkActionResult OBJECT-TYPE
+ SYNTAX INTEGER {
+ succeeded(0)
+,
+ inProgress(1)
+,
+ failed(2)
+
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Management field for ACTIONS RESULT.
+AC INI-Param: SS7_LINKSETLINK_ACTION_RESULT"
+ ::= {acSS7LinkSetLinkEntry 6}
+
+
+
+ acSS7LinkSetLinkLinkNo OBJECT-TYPE
+ SYNTAX Unsigned32 (0..128)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Physical number of signalling link which is part of the Linkset.
+Access: Online.
+AC INI-Param: SS7_LINKSETLINK_LINK_NUMBER"
+ ::= {acSS7LinkSetLinkEntry 7}
+
+
+
+ acSS7LinkSetLinkLinkSlc OBJECT-TYPE
+ SYNTAX Unsigned32 (0..15)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "SLC number of signaling link which is part of the Linkset.
+Access: Online.
+AC INI-Param: SS7_LINKSETLINK_LINK_SLC"
+ ::= {acSS7LinkSetLinkEntry 8}
+
+
+
+ acSS7RouteSets OBJECT IDENTIFIER ::= {acSS7Nodes 32}
+
+
+ -- ****************************************
+ -- acSS7RouteSet table declaration
+ -- ****************************************
+ acSS7RouteSetTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcSS7RouteSetEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ ::= {acSS7RouteSets 21}
+
+
+
+ -- ****************************************
+ -- acSS7RouteSet table entry
+ -- ****************************************
+ acSS7RouteSetEntry OBJECT-TYPE
+ SYNTAX AcSS7RouteSetEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX {acSS7RouteSetSNIndex,acSS7RouteSetIndex}
+ ::= {acSS7RouteSetTable 1}
+
+
+
+ -- ****************************************
+ -- acSS7RouteSet TABLE
+ -- ****************************************
+ AcSS7RouteSetEntry ::= SEQUENCE {
+ acSS7RouteSetSNIndex Unsigned32,
+ acSS7RouteSetIndex Unsigned32,
+ acSS7RouteSetRowStatus RowStatus,
+ acSS7RouteSetAction INTEGER,
+ acSS7RouteSetActionResult INTEGER,
+ acSS7RouteSetName SnmpAdminString,
+ acSS7RouteSetAdminState INTEGER,
+ acSS7RouteSetOperState INTEGER,
+ acSS7RouteSetDPC Unsigned32,
+ acSS7RouteSetRouteMask Unsigned32
+ }
+
+
+
+ acSS7RouteSetSNIndex OBJECT-TYPE
+ SYNTAX Unsigned32 (0..1)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "First Index Field for line: Signalling Node Number.
+AC INI-Param: SS7_ROUTESET_SN_INDEX"
+ ::= {acSS7RouteSetEntry 1}
+
+
+
+ acSS7RouteSetIndex OBJECT-TYPE
+ SYNTAX Unsigned32 (0..29)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Second Index Field for line: Signalling Routeset Number.
+AC INI-Param: SS7_ROUTESET_INDEX"
+ ::= {acSS7RouteSetEntry 2}
+
+
+
+ acSS7RouteSetRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "ROWSTATUS Field for line.
+AC INI-Param: SS7_ROUTESET_ROWSTATUS"
+ ::= {acSS7RouteSetEntry 3}
+
+
+
+ acSS7RouteSetAction OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(0)
+,
+ offLine(1)
+,
+ inService(2)
+
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "management Field for ACTIONS.
+AC INI-Param: SS7_ROUTESET_ACTION"
+ ::= {acSS7RouteSetEntry 4}
+
+
+
+ acSS7RouteSetActionResult OBJECT-TYPE
+ SYNTAX INTEGER {
+ succeeded(0)
+,
+ inProgress(1)
+,
+ failed(2)
+
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "management Field for ACTIONS RESULT.
+AC INI-Param: SS7_ROUTESET_ACTION_RESULT"
+ ::= {acSS7RouteSetEntry 5}
+
+
+
+ acSS7RouteSetName OBJECT-TYPE
+ SYNTAX SnmpAdminString (SIZE (0..15))
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "String name for ROUTESET Params.
+Access: Online.
+AC INI-Param: SS7_ROUTESET_NAME"
+ ::= {acSS7RouteSetEntry 6}
+
+
+
+ acSS7RouteSetAdminState OBJECT-TYPE
+ SYNTAX INTEGER {
+ offLine(0)
+,
+ inService(2)
+
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Administrative state of signalling route set.
+AC INI-Param: SS7_ROUTESET_ADMINISTRATIVE_STATE"
+ ::= {acSS7RouteSetEntry 7}
+
+
+
+ acSS7RouteSetOperState OBJECT-TYPE
+ SYNTAX INTEGER {
+ offLine(0)
+,
+ busy(1)
+,
+ inService(2)
+
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Operational state of signalling route set.
+AC INI-Param: SS7_ROUTESET_OPERATIONAL_STATE"
+ ::= {acSS7RouteSetEntry 8}
+
+
+
+ acSS7RouteSetDPC OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2147483647)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Destination Point-Code of singnalling routesetset.
+Access: Online.
+AC INI-Param: SS7_ROUTESET_DPC"
+ ::= {acSS7RouteSetEntry 9}
+
+
+
+ acSS7RouteSetRouteMask OBJECT-TYPE
+ SYNTAX Unsigned32 (0..255)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Mask for route within signaling routeset.
+Access: Online.
+AC INI-Param: SS7_ROUTESET_MASK"
+ ::= {acSS7RouteSetEntry 10}
+
+
+
+ -- ****************************************
+ -- acSS7RouteSetRoute table declaration
+ -- ****************************************
+ acSS7RouteSetRouteTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcSS7RouteSetRouteEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ ::= {acSS7RouteSets 22}
+
+
+
+ -- ****************************************
+ -- acSS7RouteSetRoute table entry
+ -- ****************************************
+ acSS7RouteSetRouteEntry OBJECT-TYPE
+ SYNTAX AcSS7RouteSetRouteEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX {acSS7RouteSetRouteSNIndex,acSS7RouteSetRouteRoutesetIndex,acSS7RouteSetRouteInnerRouteIndex}
+ ::= {acSS7RouteSetRouteTable 1}
+
+
+
+ -- ****************************************
+ -- acSS7RouteSetRoute TABLE
+ -- ****************************************
+ AcSS7RouteSetRouteEntry ::= SEQUENCE {
+ acSS7RouteSetRouteSNIndex Unsigned32,
+ acSS7RouteSetRouteRoutesetIndex Unsigned32,
+ acSS7RouteSetRouteInnerRouteIndex Unsigned32,
+ acSS7RouteSetRouteRowStatus RowStatus,
+ acSS7RouteSetRouteAction INTEGER,
+ acSS7RouteSetRouteActionResult INTEGER,
+ acSS7RouteSetRouteLinkSetNo Unsigned32,
+ acSS7RouteSetRoutePriority Unsigned32
+ }
+
+
+
+ acSS7RouteSetRouteSNIndex OBJECT-TYPE
+ SYNTAX Unsigned32 (0..1)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "First Index Field for line: Signalling Node Number.
+AC INI-Param: SS7_ROUTESETROUTE_SN_INDEX"
+ ::= {acSS7RouteSetRouteEntry 1}
+
+
+
+ acSS7RouteSetRouteRoutesetIndex OBJECT-TYPE
+ SYNTAX Unsigned32 (0..29)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Second Index Field for line: Signalling Routeset Number.
+AC INI-Param: SS7_ROUTESETROUTE_ROUTESET_INDEX"
+ ::= {acSS7RouteSetRouteEntry 2}
+
+
+
+ acSS7RouteSetRouteInnerRouteIndex OBJECT-TYPE
+ SYNTAX Unsigned32 (0..3)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Third Index Field for line: Inner Route Index in Signalling
+Routeset.
+AC INI-Param: SS7_ROUTESETROUTE_INNER_ROUTE_INDEX"
+ ::= {acSS7RouteSetRouteEntry 3}
+
+
+
+ acSS7RouteSetRouteRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "ROWSTATUS Field for line.
+AC INI-Param: SS7_ROUTESETROUTE_ROWSTATUS"
+ ::= {acSS7RouteSetRouteEntry 4}
+
+
+
+ acSS7RouteSetRouteAction OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(0)
+
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "management Field for ACTIONS.
+AC INI-Param: SS7_ROUTESETROUTE_ACTION"
+ ::= {acSS7RouteSetRouteEntry 5}
+
+
+
+ acSS7RouteSetRouteActionResult OBJECT-TYPE
+ SYNTAX INTEGER {
+ succeeded(0)
+,
+ inProgress(1)
+,
+ failed(2)
+
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "management Field for ACTIONS RESULT.
+AC INI-Param: SS7_ROUTESETROUTE_ACTION_RESULT"
+ ::= {acSS7RouteSetRouteEntry 6}
+
+
+
+ acSS7RouteSetRouteLinkSetNo OBJECT-TYPE
+ SYNTAX Unsigned32 (0..128)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Number of signalling linkset which is part of the Routeset.
+Access: Online.
+AC INI-Param: SS7_ROUTESETROUTE_LINKSET_NUMBER"
+ ::= {acSS7RouteSetRouteEntry 7}
+
+
+
+ acSS7RouteSetRoutePriority OBJECT-TYPE
+ SYNTAX Unsigned32 (0..254)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Priority of route within routeset.
+Access: Online.
+AC INI-Param: SS7_ROUTESETROUTE_PRIORITY"
+ ::= {acSS7RouteSetRouteEntry 8}
+
+
+
+ acSS7AliasPointCode OBJECT IDENTIFIER ::= {acSS7Nodes 33}
+
+
+ -- ****************************************
+ -- acSS7APC table declaration
+ -- ****************************************
+ acSS7APCTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcSS7APCEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ ::= {acSS7AliasPointCode 21}
+
+
+
+ -- ****************************************
+ -- acSS7APC table entry
+ -- ****************************************
+ acSS7APCEntry OBJECT-TYPE
+ SYNTAX AcSS7APCEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX {acSS7APCSNIndex,acSS7APCIndex}
+ ::= {acSS7APCTable 1}
+
+
+
+ -- ****************************************
+ -- acSS7APC TABLE
+ -- ****************************************
+ AcSS7APCEntry ::= SEQUENCE {
+ acSS7APCSNIndex Unsigned32,
+ acSS7APCIndex Unsigned32,
+ acSS7APCRowStatus RowStatus,
+ acSS7APCAction INTEGER,
+ acSS7APCActionResult INTEGER,
+ acSS7APCPC Unsigned32,
+ acSS7APCSNI Unsigned32,
+ acSS7APCName SnmpAdminString,
+ acSS7APCMtcBusy INTEGER,
+ acSS7APCAdminState INTEGER,
+ acSS7APCOperState INTEGER
+ }
+
+
+
+ acSS7APCSNIndex OBJECT-TYPE
+ SYNTAX Unsigned32 (0..1)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "First Index Field for line: Signaling Node Number.
+AC INI-Param: SS7_APC_SN_INDEX"
+ ::= {acSS7APCEntry 1}
+
+
+
+ acSS7APCIndex OBJECT-TYPE
+ SYNTAX Unsigned32 (0..1)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Second Index Field for line: Alias PC index.
+AC INI-Param: SS7_APC_INNER_INDEX"
+ ::= {acSS7APCEntry 2}
+
+
+
+ acSS7APCRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "ROWSTATUS Field for line.
+AC INI-Param: SS7_APC_ROWSTATUS"
+ ::= {acSS7APCEntry 3}
+
+
+
+ acSS7APCAction OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(0)
+,
+ offLine(1)
+,
+ inService(2)
+,
+ activate(3)
+,
+ deActivate(4)
+
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Management field for ACTIONS.
+AC INI-Param: SS7_APC_ACTION"
+ ::= {acSS7APCEntry 4}
+
+
+
+ acSS7APCActionResult OBJECT-TYPE
+ SYNTAX INTEGER {
+ succeeded(0)
+,
+ inProgress(1)
+,
+ failed(2)
+
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "management Field for ACTIONS RESULT.
+AC INI-Param: SS7_APC_ACTION_RESULT"
+ ::= {acSS7APCEntry 5}
+
+
+
+ acSS7APCPC OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2147483647)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Alias Point-Code of signaling node.
+Access: Online.
+AC INI-Param: SS7_APC_PC"
+ ::= {acSS7APCEntry 6}
+
+
+
+ acSS7APCSNI OBJECT-TYPE
+ SYNTAX Unsigned32 (2..5)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "SNI (Signaling Network Indicator) of Alias Point-Code.
+Access: Online.
+AC INI-Param: SS7_APC_SNI"
+ ::= {acSS7APCEntry 7}
+
+
+
+ acSS7APCName OBJECT-TYPE
+ SYNTAX SnmpAdminString (SIZE (0..15))
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "String name for Alias PC parameters.
+Access: Online.
+AC INI-Param: SS7_ALIAS_PC_NAME"
+ ::= {acSS7APCEntry 8}
+
+
+
+ acSS7APCMtcBusy OBJECT-TYPE
+ SYNTAX INTEGER {
+ no(0)
+,
+ yes(1)
+
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Manual busy status of Alias PC.
+AC INI-Param: SS7_ALIAS_PC_MTC_BUSY"
+ ::= {acSS7APCEntry 9}
+
+
+
+ acSS7APCAdminState OBJECT-TYPE
+ SYNTAX INTEGER {
+ offLine(0)
+,
+ busy(1)
+,
+ inService(2)
+
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Administrative state of Alias PC.
+AC INI-Param: SS7_ALIAS_PC_ADMINISTRATIVE_STATE"
+ ::= {acSS7APCEntry 10}
+
+
+
+ acSS7APCOperState OBJECT-TYPE
+ SYNTAX INTEGER {
+ offLine(0)
+,
+ busy(1)
+,
+ inService(2)
+
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Operational state of Alias PC.
+AC INI-Param: SS7_ALIAS_PC_OPERATIONAL_STATE"
+ ::= {acSS7APCEntry 11}
+
+
+
+ acSS7SigTran OBJECT IDENTIFIER ::= {acSS7Configuration 5}
+
+
+ acSS7SigTranM3UATrafficBehavior OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(0)
+,
+ deactivate(1)
+,
+ sIPO(2)
+
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Defines the M3UA behavior when the SS7 links are up, but there
+is no association to the soft switch.
+
+0 = NONE (no special behavior)
+1 = DEACTIVATE (busy links)
+2 = SIPO (LPO links).
+Access: Offline.
+AC INI-Param: SS7M3UATrafficBehavior"
+ ::= {acSS7SigTran 1}
+
+
+
+ -- ****************************************
+ -- acSS7SigTranIFGroup table declaration
+ -- ****************************************
+ acSS7SigTranIFGroupTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcSS7SigTranIFGroupEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ ::= {acSS7SigTran 21}
+
+
+
+ -- ****************************************
+ -- acSS7SigTranIFGroup table entry
+ -- ****************************************
+ acSS7SigTranIFGroupEntry OBJECT-TYPE
+ SYNTAX AcSS7SigTranIFGroupEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX {acSS7SigTranIFGroupIndex}
+ ::= {acSS7SigTranIFGroupTable 1}
+
+
+
+ -- ****************************************
+ -- acSS7SigTranIFGroup TABLE
+ -- ****************************************
+ AcSS7SigTranIFGroupEntry ::= SEQUENCE {
+ acSS7SigTranIFGroupIndex Unsigned32,
+ acSS7SigTranIFGroupRowStatus RowStatus,
+ acSS7SigTranIFGroupAction INTEGER,
+ acSS7SigTranIFGroupActionResult Unsigned32,
+ acSS7SigTranIFGroupId Unsigned32,
+ acSS7SigTranIFGroupSgMgc INTEGER,
+ acSS7SigTranIFGroupSignalingLayer INTEGER,
+ acSS7SigTranIFGroupTrafMode INTEGER,
+ acSS7SigTranIFGroupRecovTimer Unsigned32,
+ acSS7SigTranIFGroupAckTimer Unsigned32,
+ acSS7SigTranIFGroupHBTimer Unsigned32,
+ acSS7SigTranIFGroupMinAsp Unsigned32,
+ acSS7SigTranIFGroupBehavior Unsigned32,
+ acSS7SigTranIFGroupSCTPInst Unsigned32,
+ acSS7SigTranIFGroupSCTPLocalPort Unsigned32,
+ acSS7SigTranIFGroupNetwork INTEGER,
+ acSS7SigTranIFGroupSCTPDestPort Unsigned32,
+ acSS7SigTranIFGroupDestIp IpAddress,
+ acSS7SigTranIFGroupSCTPMaxInbStreams Unsigned32,
+ acSS7SigTranIFGroupSCTPMaxOutbStreams Unsigned32,
+ acSS7SigTranIFGroupRdcyBoardNum Unsigned32,
+ acSS7SigTranIFGroupRoutingContextIndex Integer32,
+ acSS7SigTranIFGroupRoutingContextValue Integer32,
+ acSS7SigTranIFGroupNetworkAppearance Integer32
+ }
+
+
+
+ acSS7SigTranIFGroupIndex OBJECT-TYPE
+ SYNTAX Unsigned32 (0..15)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Index field for line.
+AC INI-Param: SS7_SIG_IF_GR_INDEX"
+ ::= {acSS7SigTranIFGroupEntry 1}
+
+
+
+ acSS7SigTranIFGroupRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "ROWSTATUS field for line.
+AC INI-Param: SS7_SIG_IF_GR_ROWSTATUS"
+ ::= {acSS7SigTranIFGroupEntry 2}
+
+
+
+ acSS7SigTranIFGroupAction OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(0)
+,
+ activate(1)
+,
+ deActivate(2)
+
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Management field for ACTION.
+AC INI-Param: SS7_SIG_IF_GR_ACTION"
+ ::= {acSS7SigTranIFGroupEntry 3}
+
+
+
+ acSS7SigTranIFGroupActionResult OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Management field for ACTION RESULT.
+AC INI-Param: SS7_SIG_IF_GR_ACTION_RESULT"
+ ::= {acSS7SigTranIFGroupEntry 4}
+
+
+
+ acSS7SigTranIFGroupId OBJECT-TYPE
+ SYNTAX Unsigned32 (0..65534)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "SS7 (Signaling System 7) SIGTRAN (Signaling Transport) Interface
+Group Id.
+Access: Online.
+AC INI-Param: SS7_IF_GR_ID"
+ ::= {acSS7SigTranIFGroupEntry 5}
+
+
+
+ acSS7SigTranIFGroupSgMgc OBJECT-TYPE
+ SYNTAX INTEGER {
+ nat(1)
+,
+ mgc(77)
+,
+ sg(83)
+
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Interface Group function - Signaling Gateway (SG) or Media Gateway
+Controller (MGC).
+Access: Online.
+AC INI-Param: SS7_SIG_SG_MGC"
+ ::= {acSS7SigTranIFGroupEntry 6}
+
+
+
+ acSS7SigTranIFGroupSignalingLayer OBJECT-TYPE
+ SYNTAX INTEGER {
+ noLayer(0)
+,
+ iua(1)
+,
+ m2ua(2)
+,
+ m3ua(3)
+,
+ m2tunnel(4)
+,
+ dua(6)
+
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "UAL type of interface group:
+0 = none
+1 = iua
+2 = m2ua
+3 = m3ua
+4 = m2tunnel
+6 = dua.
+Access: Online.
+AC INI-Param: SS7_SIG_LAYER"
+ ::= {acSS7SigTranIFGroupEntry 7}
+
+
+
+ acSS7SigTranIFGroupTrafMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ override(1)
+,
+ loadShare(2)
+,
+ broadcast(3)
+
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Traffic mode of interface group.
+Access: Online.
+AC INI-Param: SS7_SIG_TRAF_MODE"
+ ::= {acSS7SigTranIFGroupEntry 8}
+
+
+
+ acSS7SigTranIFGroupRecovTimer OBJECT-TYPE
+ SYNTAX Unsigned32 (0..10000000)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "T(r) - recovery timer (in msecs) of interface group.
+Access: Online.
+AC INI-Param: SS7_SIG_T_REC"
+ ::= {acSS7SigTranIFGroupEntry 9}
+
+
+
+ acSS7SigTranIFGroupAckTimer OBJECT-TYPE
+ SYNTAX Unsigned32 (0..10000000)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "T(ack) - wait timer for ASP_UP_ACK (in msecs) of interface group.
+Access: Online.
+AC INI-Param: SS7_SIG_T_ACK"
+ ::= {acSS7SigTranIFGroupEntry 10}
+
+
+
+ acSS7SigTranIFGroupHBTimer OBJECT-TYPE
+ SYNTAX Unsigned32 (0..10000000)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "T(beat) - Heartbeat Timer (in msecs) of interface group.
+Access: Online.
+AC INI-Param: SS7_SIG_T_HB"
+ ::= {acSS7SigTranIFGroupEntry 11}
+
+
+
+ acSS7SigTranIFGroupMinAsp OBJECT-TYPE
+ SYNTAX Unsigned32 (1..10)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Minimal ASP (Application Server Process) number in interface
+group(minimum = 1).
+Access: Online.
+AC INI-Param: SS7_SIG_MIN_ASP"
+ ::= {acSS7SigTranIFGroupEntry 12}
+
+
+
+ acSS7SigTranIFGroupBehavior OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2147483647)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Behavior bit of interface group.
+Access: Online.
+AC INI-Param: SS7_SIG_BEHAVIOUR"
+ ::= {acSS7SigTranIFGroupEntry 13}
+
+
+
+ acSS7SigTranIFGroupSCTPInst OBJECT-TYPE
+ SYNTAX Unsigned32 (0..65534)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "SCTP (Stream Control Transmission Protocol) instance of interface
+group.
+AC INI-Param: SS7_SCTP_INSTANCE"
+ ::= {acSS7SigTranIFGroupEntry 14}
+
+
+
+ acSS7SigTranIFGroupSCTPLocalPort OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2147483647)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Local SCTP (Stream Control Transmission Protocol) port of interface
+group.
+Access: Online.
+AC INI-Param: SS7_LOCAL_SCTP_PORT"
+ ::= {acSS7SigTranIFGroupEntry 15}
+
+
+
+ acSS7SigTranIFGroupNetwork OBJECT-TYPE
+ SYNTAX INTEGER {
+ itu(1)
+,
+ ansi(2)
+,
+ china(3)
+
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Network variant of interface group.
+Access: Online.
+AC INI-Param: SS7_SIG_NETWORK"
+ ::= {acSS7SigTranIFGroupEntry 16}
+
+
+
+ acSS7SigTranIFGroupSCTPDestPort OBJECT-TYPE
+ SYNTAX Unsigned32 (0..65534)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Destination SCTP (Stream Control Transmission Protocol) port.
+Access: Online.
+AC INI-Param: SS7_DEST_SCTP_PORT"
+ ::= {acSS7SigTranIFGroupEntry 17}
+
+
+
+ acSS7SigTranIFGroupDestIp OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Destination SCTP (Stream Control Transmission Protocol) IP address.
+Access: Online.
+AC INI-Param: SS7_DEST_IP"
+ ::= {acSS7SigTranIFGroupEntry 18}
+
+
+
+ acSS7SigTranIFGroupSCTPMaxInbStreams OBJECT-TYPE
+ SYNTAX Unsigned32 (2..65534)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Maximum inbound streams in interface group.
+Access: Online.
+AC INI-Param: SS7_MGC_MX_IN_STREAM"
+ ::= {acSS7SigTranIFGroupEntry 19}
+
+
+
+ acSS7SigTranIFGroupSCTPMaxOutbStreams OBJECT-TYPE
+ SYNTAX Unsigned32 (2..65534)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Number of output streams required in interface group.
+Access: Online.
+AC INI-Param: SS7_MGC_NUM_OUT_STREAM"
+ ::= {acSS7SigTranIFGroupEntry 20}
+
+
+
+ acSS7SigTranIFGroupRdcyBoardNum OBJECT-TYPE
+ SYNTAX Unsigned32 (0..255)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This parameter is used to specify the SIGTRAN (Signaling Transport)
+group redundancy board number.
+Access: Online.
+AC INI-Param: RdcyBoardNum"
+ ::= {acSS7SigTranIFGroupEntry 21}
+
+
+
+ acSS7SigTranIFGroupRoutingContextIndex OBJECT-TYPE
+ SYNTAX Integer32 (-1..15)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Entry in Routing Context table, that contains the routing context
+rules for this interface group.
+Access: Online.
+AC INI-Param: SS7_SIG_RC_INDEX"
+ ::= {acSS7SigTranIFGroupEntry 22}
+
+
+
+ acSS7SigTranIFGroupRoutingContextValue OBJECT-TYPE
+ SYNTAX Integer32 (-1..2147483647)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Routing context value for this interface group (AS).
+Access: Online.
+AC INI-Param: SS7_SIG_RC_VALUE"
+ ::= {acSS7SigTranIFGroupEntry 23}
+
+
+
+ acSS7SigTranIFGroupNetworkAppearance OBJECT-TYPE
+ SYNTAX Integer32 (-1..2147483647)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Network Appearance value for this interface group (AS).
+Access: Online.
+AC INI-Param: SS7_SIG_NETWORK_APPEARANCE"
+ ::= {acSS7SigTranIFGroupEntry 24}
+
+
+
+ -- ****************************************
+ -- acSS7SigTranIFID table declaration
+ -- ****************************************
+ acSS7SigTranIFIDTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcSS7SigTranIFIDEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ ::= {acSS7SigTran 22}
+
+
+
+ -- ****************************************
+ -- acSS7SigTranIFID table entry
+ -- ****************************************
+ acSS7SigTranIFIDEntry OBJECT-TYPE
+ SYNTAX AcSS7SigTranIFIDEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX {acSS7SigTranIFIDIndex}
+ ::= {acSS7SigTranIFIDTable 1}
+
+
+
+ -- ****************************************
+ -- acSS7SigTranIFID TABLE
+ -- ****************************************
+ AcSS7SigTranIFIDEntry ::= SEQUENCE {
+ acSS7SigTranIFIDIndex Unsigned32,
+ acSS7SigTranIFIDRowStatus RowStatus,
+ acSS7SigTranIFIDAction INTEGER,
+ acSS7SigTranIFIDActionResult Unsigned32,
+ acSS7SigTranIFIDValue Unsigned32,
+ acSS7SigTranIFIDName SnmpAdminString,
+ acSS7SigTranIFIDOwnerGroup Integer32,
+ acSS7SigTranIFIDSignalingLayer INTEGER,
+ acSS7SigTranIFIDNai Integer32,
+ acSS7SigTranIFIDM3UASpc Unsigned32
+ }
+
+
+
+ acSS7SigTranIFIDIndex OBJECT-TYPE
+ SYNTAX Unsigned32 (0..83)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Index field for line.
+AC INI-Param: SS7_SIG_IF_ID_INDEX"
+ ::= {acSS7SigTranIFIDEntry 1}
+
+
+
+ acSS7SigTranIFIDRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "ROWSTATUS field for line.
+AC INI-Param: SS7_SIG_IF_ID_ROWSTATUS"
+ ::= {acSS7SigTranIFIDEntry 2}
+
+
+
+ acSS7SigTranIFIDAction OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(0)
+,
+ activate(1)
+,
+ deActivate(2)
+
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Management field for ACTION.
+AC INI-Param: SS7_SIG_IF_ID_ACTION"
+ ::= {acSS7SigTranIFIDEntry 3}
+
+
+
+ acSS7SigTranIFIDActionResult OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Management field for ACTION RESULT.
+AC INI-Param: SS7_SIG_IF_ID_ACTION_RESULT"
+ ::= {acSS7SigTranIFIDEntry 4}
+
+
+
+ acSS7SigTranIFIDValue OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2147483647)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "SS7 (Signaling System 7) SIGTRAN (Signaling Transport) interface
+ID value.
+Access: Online.
+AC INI-Param: SS7_SIG_IF_ID_VALUE"
+ ::= {acSS7SigTranIFIDEntry 5}
+
+
+
+ acSS7SigTranIFIDName OBJECT-TYPE
+ SYNTAX SnmpAdminString (SIZE (0..15))
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "SS7 (Signaling System 7) SIGTRAN (Signaling Transport) interface
+ID name (text string).
+Access: Online.
+AC INI-Param: SS7_SIG_IF_ID_NAME"
+ ::= {acSS7SigTranIFIDEntry 6}
+
+
+
+ acSS7SigTranIFIDOwnerGroup OBJECT-TYPE
+ SYNTAX Integer32 (-1..65534)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Owner group of interface id.
+Access: Online.
+AC INI-Param: SS7_SIG_IF_ID_OWNER_GROUP"
+ ::= {acSS7SigTranIFIDEntry 7}
+
+
+
+ acSS7SigTranIFIDSignalingLayer OBJECT-TYPE
+ SYNTAX INTEGER {
+ noLayer(0)
+,
+ iua(1)
+,
+ m2ua(2)
+,
+ m2tunnel(4)
+,
+ dua(6)
+
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "UAL Type of interface id:
+0 = none
+1 = iua
+2 = m2ua
+4 = m2tunnel
+6 = dua.
+Access: Online.
+AC INI-Param: SS7_SIG_IF_ID_LAYER"
+ ::= {acSS7SigTranIFIDEntry 8}
+
+
+
+ acSS7SigTranIFIDNai OBJECT-TYPE
+ SYNTAX Integer32 (-2..124)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "NAI of interface id.
+Access: Online.
+AC INI-Param: SS7_SIG_IF_ID_NAI"
+ ::= {acSS7SigTranIFIDEntry 9}
+
+
+
+ acSS7SigTranIFIDM3UASpc OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2147483647)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This parameter is used to specify the SIGTRAN (Signaling Transport)
+M3UA (M3UA - SS7 MTP3-User Adaptation Layer) SPC.
+Access: Online.
+AC INI-Param: SS7_SIG_M3UA_SPC"
+ ::= {acSS7SigTranIFIDEntry 10}
+
+
+
+ -- ****************************************
+ -- acSS7M3UAStaticRouting table declaration
+ -- ****************************************
+ acSS7M3UAStaticRoutingTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcSS7M3UAStaticRoutingEntry
+ MAX-ACCESS not-accessible
+ STATUS obsolete
+ DESCRIPTION
+ ""
+ ::= {acSS7SigTran 23}
+
+
+
+ -- ****************************************
+ -- acSS7M3UAStaticRouting table entry
+ -- ****************************************
+ acSS7M3UAStaticRoutingEntry OBJECT-TYPE
+ SYNTAX AcSS7M3UAStaticRoutingEntry
+ MAX-ACCESS not-accessible
+ STATUS obsolete
+ DESCRIPTION
+ ""
+ INDEX {acSS7M3UAStaticRoutingIndex}
+ ::= {acSS7M3UAStaticRoutingTable 1}
+
+
+
+ -- ****************************************
+ -- acSS7M3UAStaticRouting TABLE
+ -- ****************************************
+ AcSS7M3UAStaticRoutingEntry ::= SEQUENCE {
+ acSS7M3UAStaticRoutingIndex Unsigned32,
+ acSS7M3UAStaticRoutingRowStatus RowStatus,
+ acSS7M3UAStaticRoutingAction INTEGER,
+ acSS7M3UAStaticRoutingActionResult Unsigned32,
+ acSS7M3UAStaticRoutingOwnerInterfaceGroup Unsigned32,
+ acSS7M3UAStaticRoutingRC Unsigned32,
+ acSS7M3UAStaticRoutingDestinationPointCode Unsigned32,
+ acSS7M3UAStaticRoutingNetworkAppearence Unsigned32,
+ acSS7M3UAStaticRoutingSeriviceIndicatorList Unsigned32,
+ acSS7M3UAStaticRoutingOPC1 Unsigned32,
+ acSS7M3UAStaticRoutingOPC2 Unsigned32,
+ acSS7M3UAStaticRoutingOPC3 Unsigned32,
+ acSS7M3UAStaticRoutingOPC4 Unsigned32,
+ acSS7M3UAStaticRoutingLowerCICValue1 Unsigned32,
+ acSS7M3UAStaticRoutingUpperCICValue1 Unsigned32,
+ acSS7M3UAStaticRoutingLowerCICValue2 Unsigned32,
+ acSS7M3UAStaticRoutingUpperCICValue2 Unsigned32,
+ acSS7M3UAStaticRoutingLowerCICValue3 Unsigned32,
+ acSS7M3UAStaticRoutingUpperCICValue3 Unsigned32,
+ acSS7M3UAStaticRoutingLowerCICValue4 Unsigned32,
+ acSS7M3UAStaticRoutingUpperCICValue4 Unsigned32
+ }
+
+
+
+ acSS7M3UAStaticRoutingIndex OBJECT-TYPE
+ SYNTAX Unsigned32 (0..100)
+ MAX-ACCESS not-accessible
+ STATUS obsolete
+ DESCRIPTION
+ "This parameter is used for the Signaling System 7 (SS7) interface
+ID index, for a line.
+AC INI-Param: M3UAROUTINGCLIST_Index"
+ ::= {acSS7M3UAStaticRoutingEntry 1}
+
+
+
+ acSS7M3UAStaticRoutingRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS obsolete
+ DESCRIPTION
+ "This parameter is used for the Signaling System 7 (SS7) interface
+ID row status, for a line.
+AC INI-Param: SS7_SIG_IF_ID_ROWSTATUS"
+ ::= {acSS7M3UAStaticRoutingEntry 2}
+
+
+
+ acSS7M3UAStaticRoutingAction OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(0)
+,
+ activate(1)
+,
+ deActivate(2)
+
+ }
+ MAX-ACCESS read-create
+ STATUS obsolete
+ DESCRIPTION
+ "This parameter is used for Signaling System 7 (SS7) SIGTRAN
+(Signaling Transport) interface ID management, for actions.
+AC INI-Param: SS7_SIG_IF_ID_ACTION"
+ ::= {acSS7M3UAStaticRoutingEntry 3}
+
+
+
+ acSS7M3UAStaticRoutingActionResult OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2147483647)
+ MAX-ACCESS read-only
+ STATUS obsolete
+ DESCRIPTION
+ "This parameter is used for Signaling System 7 (SS7) SIGTRAN
+(Signaling Transport) interface ID management, for an action's
+results.
+AC INI-Param: SS7_SIG_IF_ID_ACTION_RESULT"
+ ::= {acSS7M3UAStaticRoutingEntry 4}
+
+
+
+ acSS7M3UAStaticRoutingOwnerInterfaceGroup OBJECT-TYPE
+ SYNTAX Unsigned32 (0..30)
+ MAX-ACCESS read-create
+ STATUS obsolete
+ DESCRIPTION
+ "Routing Context list - for M3UA use.
+Access: Online.
+AC INI-Param: M3UAROUTINGCLIST_OwnerInterfaceGroup"
+ ::= {acSS7M3UAStaticRoutingEntry 5}
+
+
+
+ acSS7M3UAStaticRoutingRC OBJECT-TYPE
+ SYNTAX Unsigned32 (0..16777215)
+ MAX-ACCESS read-create
+ STATUS obsolete
+ DESCRIPTION
+ "Routing Context list - for M3UA use.
+Access: Online.
+AC INI-Param: M3UAROUTINGCLIST_RoutingContext"
+ ::= {acSS7M3UAStaticRoutingEntry 6}
+
+
+
+ acSS7M3UAStaticRoutingDestinationPointCode OBJECT-TYPE
+ SYNTAX Unsigned32 (0..16777215)
+ MAX-ACCESS read-create
+ STATUS obsolete
+ DESCRIPTION
+ "Routing Context list - for M3UA use.
+Access: Online.
+AC INI-Param: M3UAROUTINGCLIST_DestinationPointCode"
+ ::= {acSS7M3UAStaticRoutingEntry 7}
+
+
+
+ acSS7M3UAStaticRoutingNetworkAppearence OBJECT-TYPE
+ SYNTAX Unsigned32 (0..16777215)
+ MAX-ACCESS read-create
+ STATUS obsolete
+ DESCRIPTION
+ "Routing Context list - for M3UA use.
+Access: Online.
+AC INI-Param: M3UAROUTINGCLIST_NetworkAppearence"
+ ::= {acSS7M3UAStaticRoutingEntry 8}
+
+
+
+ acSS7M3UAStaticRoutingSeriviceIndicatorList OBJECT-TYPE
+ SYNTAX Unsigned32 (0..65535)
+ MAX-ACCESS read-create
+ STATUS obsolete
+ DESCRIPTION
+ "Routing Context list - for M3UA use.
+Access: Online.
+AC INI-Param: M3UAROUTINGCLIST_SeriviceIndicatorList"
+ ::= {acSS7M3UAStaticRoutingEntry 9}
+
+
+
+ acSS7M3UAStaticRoutingOPC1 OBJECT-TYPE
+ SYNTAX Unsigned32 (0..16777215)
+ MAX-ACCESS read-create
+ STATUS obsolete
+ DESCRIPTION
+ "Routing Context list - for M3UA use.
+Access: Online.
+AC INI-Param: M3UAROUTINGCLIST_OPC1"
+ ::= {acSS7M3UAStaticRoutingEntry 10}
+
+
+
+ acSS7M3UAStaticRoutingOPC2 OBJECT-TYPE
+ SYNTAX Unsigned32 (0..16777215)
+ MAX-ACCESS read-create
+ STATUS obsolete
+ DESCRIPTION
+ "Routing Context list - for M3UA use.
+Access: Online.
+AC INI-Param: M3UAROUTINGCLIST_OPC2"
+ ::= {acSS7M3UAStaticRoutingEntry 11}
+
+
+
+ acSS7M3UAStaticRoutingOPC3 OBJECT-TYPE
+ SYNTAX Unsigned32 (0..16777215)
+ MAX-ACCESS read-create
+ STATUS obsolete
+ DESCRIPTION
+ "Routing Context list - for M3UA use.
+Access: Online.
+AC INI-Param: M3UAROUTINGCLIST_OPC3"
+ ::= {acSS7M3UAStaticRoutingEntry 12}
+
+
+
+ acSS7M3UAStaticRoutingOPC4 OBJECT-TYPE
+ SYNTAX Unsigned32 (0..16777215)
+ MAX-ACCESS read-create
+ STATUS obsolete
+ DESCRIPTION
+ "Routing Context list - for M3UA use.
+Access: Online.
+AC INI-Param: M3UAROUTINGCLIST_OPC4"
+ ::= {acSS7M3UAStaticRoutingEntry 13}
+
+
+
+ acSS7M3UAStaticRoutingLowerCICValue1 OBJECT-TYPE
+ SYNTAX Unsigned32 (0..65535)
+ MAX-ACCESS read-create
+ STATUS obsolete
+ DESCRIPTION
+ "Routing Context list - for M3UA use.
+Access: Online.
+AC INI-Param: M3UAROUTINGCLIST_LowerCICValue1"
+ ::= {acSS7M3UAStaticRoutingEntry 14}
+
+
+
+ acSS7M3UAStaticRoutingUpperCICValue1 OBJECT-TYPE
+ SYNTAX Unsigned32 (0..65535)
+ MAX-ACCESS read-create
+ STATUS obsolete
+ DESCRIPTION
+ "Routing Context list - for M3UA use.
+Access: Online.
+AC INI-Param: M3UAROUTINGCLIST_UpperCICValue1"
+ ::= {acSS7M3UAStaticRoutingEntry 15}
+
+
+
+ acSS7M3UAStaticRoutingLowerCICValue2 OBJECT-TYPE
+ SYNTAX Unsigned32 (0..65535)
+ MAX-ACCESS read-create
+ STATUS obsolete
+ DESCRIPTION
+ "Routing Context list - for M3UA use.
+Access: Online.
+AC INI-Param: M3UAROUTINGCLIST_LowerCICValue2"
+ ::= {acSS7M3UAStaticRoutingEntry 16}
+
+
+
+ acSS7M3UAStaticRoutingUpperCICValue2 OBJECT-TYPE
+ SYNTAX Unsigned32 (0..65535)
+ MAX-ACCESS read-create
+ STATUS obsolete
+ DESCRIPTION
+ "Routing Context list - for M3UA use.
+Access: Online.
+AC INI-Param: M3UAROUTINGCLIST_UpperCICValue2"
+ ::= {acSS7M3UAStaticRoutingEntry 17}
+
+
+
+ acSS7M3UAStaticRoutingLowerCICValue3 OBJECT-TYPE
+ SYNTAX Unsigned32 (0..65535)
+ MAX-ACCESS read-create
+ STATUS obsolete
+ DESCRIPTION
+ "Routing Context list - for M3UA use.
+Access: Online.
+AC INI-Param: M3UAROUTINGCLIST_LowerCICValue3"
+ ::= {acSS7M3UAStaticRoutingEntry 18}
+
+
+
+ acSS7M3UAStaticRoutingUpperCICValue3 OBJECT-TYPE
+ SYNTAX Unsigned32 (0..65535)
+ MAX-ACCESS read-create
+ STATUS obsolete
+ DESCRIPTION
+ "Routing Context list - for M3UA use.
+Access: Online.
+AC INI-Param: M3UAROUTINGCLIST_UpperCICValue3"
+ ::= {acSS7M3UAStaticRoutingEntry 19}
+
+
+
+ acSS7M3UAStaticRoutingLowerCICValue4 OBJECT-TYPE
+ SYNTAX Unsigned32 (0..65535)
+ MAX-ACCESS read-create
+ STATUS obsolete
+ DESCRIPTION
+ "Routing Context list - for M3UA use.
+Access: Online.
+AC INI-Param: M3UAROUTINGCLIST_LowerCICValue4"
+ ::= {acSS7M3UAStaticRoutingEntry 20}
+
+
+
+ acSS7M3UAStaticRoutingUpperCICValue4 OBJECT-TYPE
+ SYNTAX Unsigned32 (0..65535)
+ MAX-ACCESS read-create
+ STATUS obsolete
+ DESCRIPTION
+ "Routing Context list - for M3UA use.
+Access: Online.
+AC INI-Param: M3UAROUTINGCLIST_UpperCICValue4"
+ ::= {acSS7M3UAStaticRoutingEntry 21}
+
+
+
+ -- ****************************************
+ -- acSS7SigTranRoutingContext table declaration
+ -- ****************************************
+ acSS7SigTranRoutingContextTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcSS7SigTranRoutingContextEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ ::= {acSS7SigTran 24}
+
+
+
+ -- ****************************************
+ -- acSS7SigTranRoutingContext table entry
+ -- ****************************************
+ acSS7SigTranRoutingContextEntry OBJECT-TYPE
+ SYNTAX AcSS7SigTranRoutingContextEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX {acSS7SigTranRoutingContextIndex,acSS7SigTranRoutingContextInnerIndex}
+ ::= {acSS7SigTranRoutingContextTable 1}
+
+
+
+ -- ****************************************
+ -- acSS7SigTranRoutingContext TABLE
+ -- ****************************************
+ AcSS7SigTranRoutingContextEntry ::= SEQUENCE {
+ acSS7SigTranRoutingContextIndex Unsigned32,
+ acSS7SigTranRoutingContextInnerIndex Unsigned32,
+ acSS7SigTranRoutingContextRowStatus RowStatus,
+ acSS7SigTranRoutingContextAction INTEGER,
+ acSS7SigTranRoutingContextActionResult Unsigned32,
+ acSS7SigTranRoutingContextSnIdx Unsigned32,
+ acSS7SigTranRoutingContextSpc Integer32,
+ acSS7SigTranRoutingContextOpc1 Integer32,
+ acSS7SigTranRoutingContextOpc2 Integer32,
+ acSS7SigTranRoutingContextOpc3 Integer32,
+ acSS7SigTranRoutingContextOpc4 Integer32,
+ acSS7SigTranRoutingContextSi1 Integer32,
+ acSS7SigTranRoutingContextSi2 Integer32,
+ acSS7SigTranRoutingContextSi3 Integer32,
+ acSS7SigTranRoutingContextSi4 Integer32
+ }
+
+
+
+ acSS7SigTranRoutingContextIndex OBJECT-TYPE
+ SYNTAX Unsigned32 (0..31)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "First index field for line.
+AC INI-Param: SS7_RC_INDEX"
+ ::= {acSS7SigTranRoutingContextEntry 1}
+
+
+
+ acSS7SigTranRoutingContextInnerIndex OBJECT-TYPE
+ SYNTAX Unsigned32 (0..3)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Second index field for line.
+AC INI-Param: SS7_RC_INNER_INDEX"
+ ::= {acSS7SigTranRoutingContextEntry 2}
+
+
+
+ acSS7SigTranRoutingContextRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "ROWSTATUS field for line.
+AC INI-Param: SS7_RC_ROW_STATUS"
+ ::= {acSS7SigTranRoutingContextEntry 3}
+
+
+
+ acSS7SigTranRoutingContextAction OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(0)
+,
+ activate(1)
+,
+ deActivate(2)
+
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Management field for ACTIONS.
+AC INI-Param: RCAction"
+ ::= {acSS7SigTranRoutingContextEntry 4}
+
+
+
+ acSS7SigTranRoutingContextActionResult OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "RCActionRes.
+AC INI-Param: SS7_RC_ACTION_RES"
+ ::= {acSS7SigTranRoutingContextEntry 5}
+
+
+
+ acSS7SigTranRoutingContextSnIdx OBJECT-TYPE
+ SYNTAX Unsigned32 (0..5)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This parameter is used to specify the M3UA Routing Context DPC
+SN-Index.
+Access: Online.
+AC INI-Param: SS7_RC_SN_INDEX"
+ ::= {acSS7SigTranRoutingContextEntry 6}
+
+
+
+ acSS7SigTranRoutingContextSpc OBJECT-TYPE
+ SYNTAX Integer32 (-1..16777215)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This parameter is used to specify the M3UA Routing Context DPC
+parameter.
+AC INI-Param: SS7_RC_SPC"
+ ::= {acSS7SigTranRoutingContextEntry 7}
+
+
+
+ acSS7SigTranRoutingContextOpc1 OBJECT-TYPE
+ SYNTAX Integer32 (-1..16777215)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This parameter is used to specify the M3UA Routing Context,First
+element of OPC list.
+Access: Online.
+AC INI-Param: SS7_RC_OPC1"
+ ::= {acSS7SigTranRoutingContextEntry 8}
+
+
+
+ acSS7SigTranRoutingContextOpc2 OBJECT-TYPE
+ SYNTAX Integer32 (-1..16777215)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This parameter is used to specify the M3UA Routing Context,Second
+element of OPC list.
+Access: Online.
+AC INI-Param: SS7_RC_OPC2"
+ ::= {acSS7SigTranRoutingContextEntry 9}
+
+
+
+ acSS7SigTranRoutingContextOpc3 OBJECT-TYPE
+ SYNTAX Integer32 (-1..16777215)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This parameter is used to specify the M3UA Routing Context,
+Third element of OPC list.
+Access: Online.
+AC INI-Param: SS7_RC_OPC3"
+ ::= {acSS7SigTranRoutingContextEntry 10}
+
+
+
+ acSS7SigTranRoutingContextOpc4 OBJECT-TYPE
+ SYNTAX Integer32 (-1..16777215)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This parameter is used to specify the M3UA Routing Context,
+Fourth element of OPC list.
+Access: Online.
+AC INI-Param: SS7_RC_OPC4"
+ ::= {acSS7SigTranRoutingContextEntry 11}
+
+
+
+ acSS7SigTranRoutingContextSi1 OBJECT-TYPE
+ SYNTAX Integer32 (-1..15)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This parameter is used to specify the M3UA Routing Context,
+First element of SI list.
+Access: Online.
+AC INI-Param: SS7_RC_SI1"
+ ::= {acSS7SigTranRoutingContextEntry 12}
+
+
+
+ acSS7SigTranRoutingContextSi2 OBJECT-TYPE
+ SYNTAX Integer32 (-1..15)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This parameter is used to specify the M3UA Routing Context,
+ Second element of SI list.
+Access: Online.
+AC INI-Param: SS7_RC_SI2"
+ ::= {acSS7SigTranRoutingContextEntry 13}
+
+
+
+ acSS7SigTranRoutingContextSi3 OBJECT-TYPE
+ SYNTAX Integer32 (-1..15)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This parameter is used to specify the M3UA Routing Context,
+ Third element of SI list.
+Access: Online.
+AC INI-Param: SS7_RC_SI3"
+ ::= {acSS7SigTranRoutingContextEntry 14}
+
+
+
+ acSS7SigTranRoutingContextSi4 OBJECT-TYPE
+ SYNTAX Integer32 (-1..15)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This parameter is used to specify the M3UA Routing Context,
+Fourth element of SI list.
+Access: Online.
+AC INI-Param: SS7_RC_SI4"
+ ::= {acSS7SigTranRoutingContextEntry 15}
+
+
+
+ acSS7Redundancy OBJECT IDENTIFIER ::= {acSS7Configuration 6}
+
+
+ acSS7RedundancyCrossLinkTransferType OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(0)
+,
+ tcp(2)
+
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Defines the cross-board connection media type for the MTP3 redundancy
+feature:
+0 = M3BRDCY_CONN_TYPE_NONE
+2 = M3BRDCY_CONN_TYPE_TCP.
+Access: Offline.
+AC INI-Param: SS7MTP3RdcyTransferType"
+ ::= {acSS7Redundancy 1}
+
+
+
+ acSS7RedundancyMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ disable(0)
+,
+ enable(1)
+
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Defines the MTP3 Signaling redundancy mode:
+0 = Disabled
+1 = Enabled
+.
+Access: Offline.
+AC INI-Param: SS7MTP3RdcyMode"
+ ::= {acSS7Redundancy 2}
+
+
+
+ acSS7RedundancyBoardNum OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Defines the board number for the SS7 (Signaling System 7) MTP3
+redundancy mode. Each board is allocated a unique number.
+All boards share a single redundancy table.
+Access: Offline.
+AC INI-Param: SS7MTP3RdcyBoardNum"
+ ::= {acSS7Redundancy 3}
+
+
+
+ acSS7RedundancyCrossLinkTraceAll OBJECT-TYPE
+ SYNTAX INTEGER {
+ disable(0)
+,
+ enable(1)
+
+ }
+ MAX-ACCESS read-write
+ STATUS obsolete
+ DESCRIPTION
+ "When set via INI-file, activates trace output for all X-links
+(only when SS7 redundancy is configured).
+.
+Access: Instant.
+AC INI-Param: SS7M3BRdcyXlinkTraceAll"
+ ::= {acSS7Redundancy 4}
+
+
+
+ acSS7RedundancyMTP3RdcyTblSyncInterval OBJECT-TYPE
+ SYNTAX Unsigned32 (0..144000)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Defines the interval between SS7 tables automatic synchronizations,
+in minutes.
+
+0 = no automatic synchronization is activated.
+.
+Access: Instant.
+AC INI-Param: N/A"
+ ::= {acSS7Redundancy 5}
+
+
+
+ acSS7RedundancySyncAllBoards OBJECT-TYPE
+ SYNTAX INTEGER {
+ noAction(0)
+,
+ sync(1)
+
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Provide SYNC all boards command.
+Access: Instant.
+AC INI-Param: N/A"
+ ::= {acSS7Redundancy 6}
+
+
+
+ acSS7RedundancySyncBoard OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Provide SYNC between this board and another specific board (parameter
+is the remote board number).
+Access: Instant.
+AC INI-Param: N/A"
+ ::= {acSS7Redundancy 7}
+
+
+
+ acSS7RedundancyKeepAliveWindow OBJECT-TYPE
+ SYNTAX Unsigned32 (1..15)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Defines redundancy X-link keep-alive tolerance window.
+(x-link between boards in Signaling System 7 (SS7) MTP3-User
+Adaptation Layer redundancy mode).
+.
+Access: Offline.
+AC INI-Param: SS7MTP3RdcyKeepAliveWindow"
+ ::= {acSS7Redundancy 8}
+
+
+
+ acSS7RedundancyKeepAliveInterval OBJECT-TYPE
+ SYNTAX Unsigned32 (0..100)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Defines redundancy X-link keep-alive interval in secs.
+(x-link between boards in Signaling System 7 (SS7) MTP3-User
+Adaptation Layer redundancy mode).
+0 = no keep-alive mechanism is activated.
+.
+Access: Offline.
+AC INI-Param: SS7MTP3RdcyKeepAliveInterval"
+ ::= {acSS7Redundancy 9}
+
+
+
+ -- ****************************************
+ -- acSS7RedundantSN table declaration
+ -- ****************************************
+ acSS7RedundantSNTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AcSS7RedundantSNEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ ::= {acSS7Redundancy 21}
+
+
+
+ -- ****************************************
+ -- acSS7RedundantSN table entry
+ -- ****************************************
+ acSS7RedundantSNEntry OBJECT-TYPE
+ SYNTAX AcSS7RedundantSNEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX {acSS7RedundantSNBoardIndex,acSS7RedundantSNIndex}
+ ::= {acSS7RedundantSNTable 1}
+
+
+
+ -- ****************************************
+ -- acSS7RedundantSN TABLE
+ -- ****************************************
+ AcSS7RedundantSNEntry ::= SEQUENCE {
+ acSS7RedundantSNBoardIndex Unsigned32,
+ acSS7RedundantSNIndex Unsigned32,
+ acSS7RedundantSNRowStatus RowStatus,
+ acSS7RedundantSNAction Unsigned32,
+ acSS7RedundantSNActionRes Unsigned32,
+ acSS7RedundantSNBoardIp IpAddress,
+ acSS7RedundantSNOPC Unsigned32,
+ acSS7RedundantSNALCAPOPC Unsigned32
+ }
+
+
+
+ acSS7RedundantSNBoardIndex OBJECT-TYPE
+ SYNTAX Unsigned32 (1..4)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "First index for a line: board number.
+AC INI-Param: SS7_RDCYSN_BOARD_INDEX"
+ ::= {acSS7RedundantSNEntry 1}
+
+
+
+ acSS7RedundantSNIndex OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Second index for a line: SN number in the board.
+AC INI-Param: SS7_RDCYSN_SN_INDEX"
+ ::= {acSS7RedundantSNEntry 2}
+
+
+
+ acSS7RedundantSNRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "ROWSTATUS field for line.
+AC INI-Param: SS7_RDCYSN_ROWSTATUS"
+ ::= {acSS7RedundantSNEntry 3}
+
+
+
+ acSS7RedundantSNAction OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2147483647)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Management field for ACTION.
+AC INI-Param: SS7_RDCYSN_ACTION"
+ ::= {acSS7RedundantSNEntry 4}
+
+
+
+ acSS7RedundantSNActionRes OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Management field for ACTION RESULT.
+AC INI-Param: SS7_RDCYSN_ACTIONRES"
+ ::= {acSS7RedundantSNEntry 5}
+
+
+
+ acSS7RedundantSNBoardIp OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "IP address of the board.
+Access: Online.
+AC INI-Param: SS7_RDCYSN_BOARD_IP"
+ ::= {acSS7RedundantSNEntry 6}
+
+
+
+ acSS7RedundantSNOPC OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2147483647)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Internal point-code of the SN (Signaling Node).
+Access: Online.
+AC INI-Param: SS7_RDCYSN_OPC"
+ ::= {acSS7RedundantSNEntry 7}
+
+
+
+ acSS7RedundantSNALCAPOPC OBJECT-TYPE
+ SYNTAX Unsigned32 (0..2147483647)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Internal point-code of ALCAP instance on a given board.
+Access: Online.
+AC INI-Param: SS7_RDCYSN_ALCAP_OPC"
+ ::= {acSS7RedundantSNEntry 8}
+
+
+
+ acSS7Status OBJECT IDENTIFIER ::= {acSS7 2}
+
+
+ acSS7Constants OBJECT IDENTIFIER ::= {acSS7Status 1}
+
+
+ acSS7ConstantsNumberOfNodes OBJECT-TYPE
+ SYNTAX Unsigned32 (0..1000)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "
+AC INI-Param: N/A"
+ ::= {acSS7Constants 1}
+
+
+
+ acSS7ConstantsNumberOfLinks OBJECT-TYPE
+ SYNTAX Unsigned32 (0..1000)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "
+AC INI-Param: N/A"
+ ::= {acSS7Constants 2}
+
+
+
+ acSS7ConstantsNumberOfLinkSetsPerSN OBJECT-TYPE
+ SYNTAX Unsigned32 (0..1000)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "
+AC INI-Param: N/A"
+ ::= {acSS7Constants 3}
+
+
+
+ acSS7ConstantsNumberOfLinksPerLinkSet OBJECT-TYPE
+ SYNTAX Unsigned32 (0..1000)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "
+AC INI-Param: N/A"
+ ::= {acSS7Constants 4}
+
+
+
+ acSS7ConstantsNumberOfRouteSetsPerSN OBJECT-TYPE
+ SYNTAX Unsigned32 (0..1000)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "
+AC INI-Param: N/A"
+ ::= {acSS7Constants 5}
+
+
+
+ acSS7ConstantsNumberOfRoutesPerRouteSets OBJECT-TYPE
+ SYNTAX Unsigned32 (0..1000)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "
+AC INI-Param: N/A"
+ ::= {acSS7Constants 6}
+
+
+
+ acSS7ConstantsNumberOfNodeTimerSets OBJECT-TYPE
+ SYNTAX Unsigned32 (0..1000)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "
+AC INI-Param: N/A"
+ ::= {acSS7Constants 7}
+
+
+
+ acSS7ConstantsNumberOfLinkSetTimerSets OBJECT-TYPE
+ SYNTAX Unsigned32 (0..1000)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "
+AC INI-Param: N/A"
+ ::= {acSS7Constants 8}
+
+
+
+
+
+END
|