+-- Revison: 1.26
+----------------------------------------------------------------
+-- 03.08.2006 wtWebGraphThermHygroSensorNo korrigiert
+--
+----------------------------------------------------------------
+-- Revison: 1.25
+----------------------------------------------------------------
+-- 28.06.2006 New: Community String Trap
+--
+----------------------------------------------------------------
+-- Revison: 1.24
+----------------------------------------------------------------
+-- 26.07.2005 #57606, WebGraph Thermo-Hygrometer
+-- CRON Zeitfunktion
+----------------------------------------------------------------
+-- Revison: 1.23
+----------------------------------------------------------------
+-- 14.07.2005 #57606, WebGraph Thermo-Hygrometer
+-- FTP Funktionen
+----------------------------------------------------------------
+-- Revison: 1.22
+----------------------------------------------------------------
+-- 17.05.2005 #57606, WebGraph Thermo-Hygrometer
+-- Trap NMS annotations
+----------------------------------------------------------------
+-- Revison: 1.21
+----------------------------------------------------------------
+-- 19.04.2005 #57606, WebGraph Thermo-Hygrometer
+-- Mail Authentication
+----------------------------------------------------------------
+-- Revison: 1.20
+----------------------------------------------------------------
+-- 05.11.2004 #57606, WebGraph Themo-Hygrometer
+-- Neu: Syslog
+--
+----------------------------------------------------------------
+-- Revison: 1.19
+----------------------------------------------------------------
+-- 08.09.2004 #57606 WebGraph Thermo-Hygrometer
+-- Neu:
+-- wtWebGraphThermHygroAlarmRHMin
+-- wtWebGraphThermHygroAlarmRHMax
+-- wtWebGraphThermHygroAlarmRHHysteresis
+-- wtWebGraphThermHygroPortSensorSelect
+-- wtWebGraphThermHygroAlarmDeltaTemp
+-- wtWebGraphThermHygroAlarmAHMin
+-- wtWebGraphThermHygroAlarmAHMax
+----------------------------------------------------------------
+-- Revison: 1.18
+----------------------------------------------------------------
+-- 21.07.2004 #57601/3/4, Webio Digital
+-- Neu:
+-- Diagnosis
+----------------------------------------------------------------
+-- Revison: 1.17
+----------------------------------------------------------------
+-- 28.06.2004 #57630/1/2, Webio Digital
+-- Neu: Puls Mode
+----------------------------------------------------------------
+-- Revison: 1.16
+----------------------------------------------------------------
+-- 16.04.2004 neu: #57632, Webio Digital EA24x24
+--
+-- #57630/1, Webio Digital EA12x12
+-- Neu:
+-- wtWebioEA12x12InputCounterClear
+----------------------------------------------------------------
+-- Revison: 1.15
+----------------------------------------------------------------
+-- 27.02.2004 #57630/1, Webio Digital EA12x12
+-- Neu:
+-- Länge erweitert auf 32 Bit:
+-- wtWebioEA12x12InputValue
+-- wtWebioEA12x12OutputValue
+-- wtWebioEA12x12LoadControlView
+-- wtWebioEA12x12LCShutDownView
+-- wtWebioEA12x12SetOutput
+-- wtWebioEA12x12AlarmInputTrigger
+-- wtWebioEA12x12AlarmOutputTrigger
+-- wtWebioEA12x12PortOutputSafetyState
+----------------------------------------------------------------
+-- Revison: 1.14
+----------------------------------------------------------------
+-- 16.02.2004 #57630/1, Webio Digital EA12x12
+-- Neu:
+-- Texte: Location, Contact
+-- SNMP: ColdStart, WarmStart, ComunityString Read/RW
+-- Alarm: ColdStart / WarmStart trigger
+--
+-- #57601, 1xWebThermometer
+-- #57603, 2xWebThermometer
+-- #57604, 8xWebThermometer
+-- Neu:
+-- Alarm Hysterese
+-- Alarm Clear Traps und Mails
+----------------------------------------------------------------
+-- Revison: 1.13
+----------------------------------------------------------------
+-- 05.02.2004 #57601, 1xWebThermometer
+-- #57603, 2xWebThermometer
+-- #57604, 8xWebThermometer
+-- Neu:
+-- Texte: Location, Contact
+-- SNMP: ColdStart, WarmStart, ComunityString Read/RW
+-- Alarm: ColdStart / WarmStart trigger
+----------------------------------------------------------------
+-- Revison: 1.12
+----------------------------------------------------------------
+-- 05.11.2003 #57601, 1xWebThermometer
+-- #57603, 2xWebThermometer
+-- #57604, 8xWebThermometer
+-- Neu:
+-- Mail Option: CSV attachment
+-- Offsetkalibrierung
+-- Alarm: Tcp Client mode
+----------------------------------------------------------------
+-- Revison: 1.11
+----------------------------------------------------------------
+-- 28.10.2003 #57630/1, Webio Digital EA12x12
+-- Neue Feature:
+-- Alarm : TCP Client mode
+-- INPUTS: Pulsfilter
+----------------------------------------------------------------
+-- Revison: 1.10
+----------------------------------------------------------------
+-- 04.07.2003 #57630, Webio Digital EA12x12
+-- Neuer Menübaum, neue Binärmodi
+--
+----------------------------------------------------------------
+-- Revison: 1.09
+----------------------------------------------------------------
+-- 24.03.2003 Trap Enterprise (Type 1, 2) korrigiert
+--
+----------------------------------------------------------------
+-- Revison: 1.08
+----------------------------------------------------------------
+-- 04.03.2003 Abgleich der Sprachversionen DE/US
+--
+----------------------------------------------------------------
+-- Revison: 1.07
+----------------------------------------------------------------
+-- 25.02.2003 Korrektur US: wtWebioEA12x12LoadControl
+----------------------------------------------------------------
+-- Revison: 1.06
+----------------------------------------------------------------
+-- 24.02.2003 Neu:
+-- #57630, Webio EA12x12, LoadControl Group
+-- Korrektur: Trap variable Namen
+----------------------------------------------------------------
+-- Revison: 1.05
+----------------------------------------------------------------
+-- 21.01.2003 Neu:
+-- #57630, Webio EA12x12
+----------------------------------------------------------------
+-- Revison: 1.04
+----------------------------------------------------------------
+-- 02.01.2003 Neu:
+-- #57601, 1xWebThermometer
+-- #57603, 2xWebThermometer, 8 Alarme
+----------------------------------------------------------------
+-- Revison: 1.03
+----------------------------------------------------------------
+-- 21.11.2002 Neu:
+-- #57604, 2xWebThermometer, BOOTP, StartupSite
+-- #57603, 8xWebThermometer, BOOTP, StartupSite
+----------------------------------------------------------------
+-- Revison: 1.02
+----------------------------------------------------------------
+-- 26.07.2002 Neu:
+-- #57604, 2xWebThermometer
+-- #57603, 8xWebThermometer
+--
+
+ IMPORTS
+
+ OBJECT-TYPE FROM RFC-1212
+ TRAP-TYPE FROM RFC-1215
+ DisplayString, PhysAddress FROM RFC1213-MIB
+ enterprises, TimeTicks, IpAddress, NetworkAddress FROM RFC1155-SMI;
+
+
+-- IpAddress ::=
+-- [APPLICATION 0]
+-- IMPLICIT OCTET STRING (SIZE (4))
+-- Counter ::=
+-- [APPLICATION 1]
+-- IMPLICIT INTEGER (0..4294967295)
+-- Gauge ::=
+-- [APPLICATION 2]
+-- IMPLICIT INTEGER (0..4294967295)
+-- TimeTicks ::=
+-- [APPLICATION 3]
+-- IMPLICIT INTEGER (0..4294967295)
+
+
+-- DisplayString ::= OCTET STRING
+-- PhysAddress ::= OCTET STRING
+
+-- internet OBJECT IDENTIFIER ::= { iso org(3) dod(6) 1 }
+-- privat OBJECT IDENTIFIER ::= { internet 4 }
+-- enterprises OBJECT IDENTIFIER ::= { privat 1 }
+
+
+
+-- Wiesemann & Theis Com-Server MIB
+
+ wut OBJECT IDENTIFIER ::= { enterprises 5040 }
+ wtComServer OBJECT IDENTIFIER ::= { wut 1 }
+ wtWebio OBJECT IDENTIFIER ::= { wtComServer 2 }
+
+
+-- wtWebGraph Tree
+
+ wtWebGraphThermHygro OBJECT IDENTIFIER ::= { wtWebio 9 }
+
+-- wtWebGraphThermHygro Tree
+
+ wtWebGraphThermHygroTemp OBJECT IDENTIFIER ::= { wtWebGraphThermHygro 1 }
+ wtWebGraphThermHygroSessCntrl OBJECT IDENTIFIER ::= { wtWebGraphThermHygro 2 }
+ wtWebGraphThermHygroConfig OBJECT IDENTIFIER ::= { wtWebGraphThermHygro 3 }
+ wtWebGraphThermHygroDiag OBJECT IDENTIFIER ::= { wtWebGraphThermHygro 4 }
+
+-- wtWebGraphThermHygroConfig Tree
+
+ wtWebGraphThermHygroDevice OBJECT IDENTIFIER ::= { wtWebGraphThermHygroConfig 1 }
+ wtWebGraphThermHygroPorts OBJECT IDENTIFIER ::= { wtWebGraphThermHygroConfig 2 }
+ wtWebGraphThermHygroManufact OBJECT IDENTIFIER ::= { wtWebGraphThermHygroConfig 3 }
+
+-- wtWebGraphThermHygroDevice Tree
+
+ wtWebGraphThermHygroText OBJECT IDENTIFIER ::= { wtWebGraphThermHygroDevice 1 }
+ wtWebGraphThermHygroTimeDate OBJECT IDENTIFIER ::= { wtWebGraphThermHygroDevice 2 }
+ wtWebGraphThermHygroBasic OBJECT IDENTIFIER ::= { wtWebGraphThermHygroDevice 3 }
+ wtWebGraphThermHygroDatalogger OBJECT IDENTIFIER ::= { wtWebGraphThermHygroDevice 4 }
+ wtWebGraphThermHygroAlarm OBJECT IDENTIFIER ::= { wtWebGraphThermHygroDevice 5 }
+
+-- wtWebGraphThermHygroTimeDate Tree
+
+ wtWebGraphThermHygroTimeZone OBJECT IDENTIFIER ::= { wtWebGraphThermHygroTimeDate 1 }
+ wtWebGraphThermHygroTimeServer OBJECT IDENTIFIER ::= { wtWebGraphThermHygroTimeDate 2 }
+ wtWebGraphThermHygroDeviceClock OBJECT IDENTIFIER ::= { wtWebGraphThermHygroTimeDate 3 }
+
+-- wtWebGraphThermHygroBasic Tree
+
+ wtWebGraphThermHygroNetwork OBJECT IDENTIFIER ::= { wtWebGraphThermHygroBasic 1 }
+ wtWebGraphThermHygroHTTP OBJECT IDENTIFIER ::= { wtWebGraphThermHygroBasic 2 }
+ wtWebGraphThermHygroMail OBJECT IDENTIFIER ::= { wtWebGraphThermHygroBasic 3 }
+ wtWebGraphThermHygroSNMP OBJECT IDENTIFIER ::= { wtWebGraphThermHygroBasic 4 }
+ wtWebGraphThermHygroUDP OBJECT IDENTIFIER ::= { wtWebGraphThermHygroBasic 5 }
+ wtWebGraphThermHygroSyslog OBJECT IDENTIFIER ::= { wtWebGraphThermHygroBasic 6 }
+ wtWebGraphThermHygroFTP OBJECT IDENTIFIER ::= { wtWebGraphThermHygroBasic 7 }
+
+
+
+-- wtWebGraphThermHygroTemp Group
+------------------------
+
+wtWebGraphThermHygroSensors OBJECT-TYPE
+ SYNTAX INTEGER (1..2)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Anzahl der Sensoren"
+ ::= { wtWebGraphThermHygroTemp 1 }
+
+-- Interface Table
+
+wtWebGraphThermHygroSensorTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF WtWebGraphThermHygroSensorEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Liste der Sensoren."
+ ::= { wtWebGraphThermHygroTemp 2 }
+
+wtWebGraphThermHygroSensorEntry OBJECT-TYPE
+ SYNTAX WtWebGraphThermHygroSensorEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Nummern der Sensoren."
+ INDEX { wtWebGraphThermHygroSensorNo }
+ ::= { wtWebGraphThermHygroSensorTable 1 }
+
+WtWebGraphThermHygroSensorEntry ::= SEQUENCE {
+ wtWebGraphThermHygroSensorNo INTEGER
+}
+
+wtWebGraphThermHygroSensorNo OBJECT-TYPE
+ SYNTAX INTEGER (1..2)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Nummer des Sensors."
+ ::= { wtWebGraphThermHygroSensorEntry 1 }
+
+
+-- wtWebGraphThermHygroTempValue Table
+
+wtWebGraphThermHygroTempValueTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF WtWebGraphThermHygroTempValueEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Liste Sensormesswerte korrespondiernd zu den Kanalnummern."
+ ::= { wtWebGraphThermHygroTemp 3 }
+
+wtWebGraphThermHygroTempValueEntry OBJECT-TYPE
+ SYNTAX WtWebGraphThermHygroTempValueEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Messwerte der Sensoren."
+ INDEX { wtWebGraphThermHygroSensorNo }
+ ::= { wtWebGraphThermHygroTempValueTable 1 }
+
+WtWebGraphThermHygroTempValueEntry ::= SEQUENCE{
+ wtWebGraphThermHygroTempValue OCTET STRING
+}
+
+wtWebGraphThermHygroTempValue OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (5))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Messwert des Sensors, ASCII, 5 Zeichen lang."
+ ::= { wtWebGraphThermHygroTempValueEntry 1 }
+
+-- wtWebGraphThermHygroBinaryTempValue Table
+
+wtWebGraphThermHygroBinaryTempValueTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF WtWebGraphThermHygroBinaryTempValueEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Liste binärer Messwerte korrespondiernd zu den Kanalnummern."
+ ::= { wtWebGraphThermHygroTemp 4 }
+
+wtWebGraphThermHygroBinaryTempValueEntry OBJECT-TYPE
+ SYNTAX WtWebGraphThermHygroBinaryTempValueEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Binäre Messwerte der Sensoren."
+ INDEX { wtWebGraphThermHygroSensorNo }
+ ::= { wtWebGraphThermHygroBinaryTempValueTable 1 }
+
+WtWebGraphThermHygroBinaryTempValueEntry ::= SEQUENCE{
+ wtWebGraphThermHygroBinaryTempValue INTEGER
+}
+
+wtWebGraphThermHygroBinaryTempValue OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Binärer Messwert des Sensors in 1/10 Grad Celcius oder 1/10 Prozent,
+ vorzeichenbehaftete Zahl, der Wert 0x4FFF6 zeigt einen
+ ungültigen Messwert an."
+ ::= { wtWebGraphThermHygroBinaryTempValueEntry 1 }
+
+-- wtWebGraphThermHygroSessCntrl Group
+--------------------------------
+
+wtWebGraphThermHygroSessCntrlPassword OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Durch Eintrag diese Passworts wird eine Session eröffnet, die durch Schreiben einer 1
+ in wtWebGraphThermHygroSessCntrlLogout beendet wird. Gelesen liefert diese Variable einen String der
+ Länge Null."
+ ::= { wtWebGraphThermHygroSessCntrl 1 }
+
+wtWebGraphThermHygroSessCntrlConfigMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ wtWebGraphThermHygroSessCntrl-NoSession(0),
+ wtWebGraphThermHygroSessCntrl-Session(1)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Wenn sich das Gerät im SNMP-Konfigurationsmodus befindet, wird der Wert
+ 1 zurückgeliefert, ansonsten 0. Ist der ausgelesene Wert 0
+ obwohl das Passwort geschrieben wurde, befindet sich das Gerät bereits
+ im Configmodus und die Variablen können nur gelesen werden."
+ ::= { wtWebGraphThermHygroSessCntrl 2 }
+
+wtWebGraphThermHygroSessCntrlLogout OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Wenn sich das Gerät im Konfigurationsmodus befindet und die Session wurde
+ von diesem SNMP Manager eröffnet, kann durch Schreiben einer 1 in diese
+ Variable die Session beendet werden und alle Parameter werden gespeichert.
+ Durch Schreiben einer 2 werden alle Eingaben wieder verworfen.
+ Gelesen liefert diese Variable den Wert 0."
+ ::= { wtWebGraphThermHygroSessCntrl 3 }
+
+wtWebGraphThermHygroSessCntrlAdminPassword OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Dieses Passwort schützt den Zugang der Variablen mit Administratorrechten. Es kann nur vom
+ Administrator verändert werden. Wurde kein Passwort vergeben so ist public das gültige Passwort.
+ Gelesen liefert diese Variable einen Null-Pointer."
+ ::= { wtWebGraphThermHygroSessCntrl 4 }
+
+wtWebGraphThermHygroSessCntrlConfigPassword OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Dieses Passwort schützt den Zugang der Variablen mit Configuratorrechten. Es kann vom
+ Administrator und vom Configurator verändert werden. Wurde kein Passwort vergeben so ist
+ public das gültige Passwort.Gelesen liefert diese Variable einen Null-Pointer."
+ ::= { wtWebGraphThermHygroSessCntrl 5 }
+
+
+-- wtWebGraphThermHygroText Group
+------------------------
+
+wtWebGraphThermHygroDeviceName OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Name des Webio's, der userdefinierbar ist."
+ ::= { wtWebGraphThermHygroText 1 }
+
+wtWebGraphThermHygroDeviceText OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Beschreibung des Webio's, die userdefinierbar ist."
+ ::= { wtWebGraphThermHygroText 2 }
+
+wtWebGraphThermHygroDeviceLocation OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Aufstellort des Webio's, die userdefinierbar ist."
+ ::= { wtWebGraphThermHygroText 3 }
+
+wtWebGraphThermHygroDeviceContact OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Kontaktadresse im Servicefall des Webio's, die userdefinierbar ist."
+ ::= { wtWebGraphThermHygroText 4 }
+
+-- wtWebGraphThermHygroTimeZone Group
+----------------------------
+
+wtWebGraphThermHygroTzOffsetHrs OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Offset Stunden der Zeitzone (Winterzeit) in Bezug auf UTC."
+ ::= { wtWebGraphThermHygroTimeZone 1 }
+
+wtWebGraphThermHygroTzOffsetMin OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Offset Minuten der Zeitzone (Winterzeit) in Bezug auf UTC."
+ ::= { wtWebGraphThermHygroTimeZone 2 }
+
+wtWebGraphThermHygroTzEnable OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(4))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Binär kodierte Bedingung:
+ Octet 1: ungenutzt
+ Octet 2: ungenutzt
+ Octet 3: ungenutzt
+ Octet 4:
+ Bit 1-7: ungenutzt
+ Bit 0 : Apply Timezone"
+ ::= { wtWebGraphThermHygroTimeZone 3 }
+
+wtWebGraphThermHygroStTzOffsetHrs OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Offset Stunden der Zeitzone (Sommerzeit) in Bezug auf UTC."
+ ::= { wtWebGraphThermHygroTimeZone 4 }
+
+wtWebGraphThermHygroStTzOffsetMin OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Offset Minuten der Zeitzone (Sommerzeit) in Bezug auf UTC."
+ ::= { wtWebGraphThermHygroTimeZone 5 }
+
+wtWebGraphThermHygroStTzEnable OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(4))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Binär kodierte Bedingung:
+ Octet 1: ungenutzt
+ Octet 2: ungenutzt
+ Octet 3: ungenutzt
+ Octet 4:
+ Bit 1-7: ungenutzt
+ Bit 0 : Apply Summertime"
+ ::= { wtWebGraphThermHygroTimeZone 6 }
+
+wtWebGraphThermHygroStTzStartMonth OBJECT-TYPE
+ SYNTAX INTEGER {
+ wtWebGraphThermHygroStartMonth-January(1),
+ wtWebGraphThermHygroStartMonth-February(2),
+ wtWebGraphThermHygroStartMonth-March(3),
+ wtWebGraphThermHygroStartMonth-April(4),
+ wtWebGraphThermHygroStartMonth-May(5),
+ wtWebGraphThermHygroStartMonth-June(6),
+ wtWebGraphThermHygroStartMonth-July(7),
+ wtWebGraphThermHygroStartMonth-August(8),
+ wtWebGraphThermHygroStartMonth-September(9),
+ wtWebGraphThermHygroStartMonth-October(10),
+ wtWebGraphThermHygroStartMonth-November(11),
+ wtWebGraphThermHygroStartMonth-December(12)
+ }
+
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Monat, in dem von Winterzeit auf Sommerzeit umgestellt wird."
+ ::= { wtWebGraphThermHygroTimeZone 7 }
+
+wtWebGraphThermHygroStTzStartMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ wtWebGraphThermHygroStartMode-first(1),
+ wtWebGraphThermHygroStartMode-second(2),
+ wtWebGraphThermHygroStartMode-third(3),
+ wtWebGraphThermHygroStartMode-fourth(4),
+ wtWebGraphThermHygroStartMode-last(5)
+ }
+
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Modus des Wochentages, bei dem von Winterzeit auf Sommerzeit umgestellt wird."
+ ::= { wtWebGraphThermHygroTimeZone 8 }
+
+wtWebGraphThermHygroStTzStartWday OBJECT-TYPE
+ SYNTAX INTEGER {
+ wtWebGraphThermHygroStartWday-Sunday(1),
+ wtWebGraphThermHygroStartWday-Monday(2),
+ wtWebGraphThermHygroStartWday-Tuesday(3),
+ wtWebGraphThermHygroStartWday-Thursday(4),
+ wtWebGraphThermHygroStartWday-Wednesday(5),
+ wtWebGraphThermHygroStartWday-Friday(6),
+ wtWebGraphThermHygroStartWday-Saturday(7)
+ }
+
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Wochentag, bei dem von Winterzeit auf Sommerzeit umgestellt wird"
+ ::= { wtWebGraphThermHygroTimeZone 9 }
+
+wtWebGraphThermHygroStTzStartHrs OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Stunde, in der die Zeitzone von Winter auf Sommerzeit in Bezug auf UTC
+ umgestellt wird."
+ ::= { wtWebGraphThermHygroTimeZone 10 }
+
+wtWebGraphThermHygroStTzStartMin OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Minute, in der die Zeitzone von Winter auf Sommerzeit in Bezug auf UTC
+ umgestellt wird."
+ ::= { wtWebGraphThermHygroTimeZone 11 }
+
+wtWebGraphThermHygroStTzStopMonth OBJECT-TYPE
+ SYNTAX INTEGER {
+ wtWebGraphThermHygroStopMonth-January(1),
+ wtWebGraphThermHygroStopMonth-February(2),
+ wtWebGraphThermHygroStopMonth-March(3),
+ wtWebGraphThermHygroStopMonth-April(4),
+ wtWebGraphThermHygroStopMonth-May(5),
+ wtWebGraphThermHygroStopMonth-June(6),
+ wtWebGraphThermHygroStopMonth-July(7),
+ wtWebGraphThermHygroStopMonth-August(8),
+ wtWebGraphThermHygroStopMonth-September(9),
+ wtWebGraphThermHygroStopMonth-October(10),
+ wtWebGraphThermHygroStopMonth-November(11),
+ wtWebGraphThermHygroStopMonth-December(12)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Monat, bei dem von Sommerzeit auf Winterzeit umgestellt wird."
+ ::= { wtWebGraphThermHygroTimeZone 12 }
+
+wtWebGraphThermHygroStTzStopMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ wtWebGraphThermHygroStopMode-first(1),
+ wtWebGraphThermHygroStopMode-second(2),
+ wtWebGraphThermHygroStopMode-third(3),
+ wtWebGraphThermHygroStopMode-fourth(4),
+ wtWebGraphThermHygroStopMode-last(5)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Modus des Wochentages, bei dem von Sommerzeit auf Winterzeit umgestellt wird."
+ ::= { wtWebGraphThermHygroTimeZone 13 }
+
+wtWebGraphThermHygroStTzStopWday OBJECT-TYPE
+ SYNTAX INTEGER {
+ wtWebGraphThermHygroStopWday-Sunday(1),
+ wtWebGraphThermHygroStopWday-Monday(2),
+ wtWebGraphThermHygroStopWday-Tuesday(3),
+ wtWebGraphThermHygroStopWday-Thursday(4),
+ wtWebGraphThermHygroStopWday-Wednesday(5),
+ wtWebGraphThermHygroStopWday-Friday(6),
+ wtWebGraphThermHygroStopWday-Saturday(7)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Wochentage, bei dem von Sommerzeit auf Winterzeit umgestellt wird."
+ ::= { wtWebGraphThermHygroTimeZone 14 }
+
+wtWebGraphThermHygroStTzStopHrs OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Stunde, in der die Zeitzone von Sommer auf Winterzeit in Bezug auf UTC
+ umgestellt wird."
+ ::= { wtWebGraphThermHygroTimeZone 15 }
+
+wtWebGraphThermHygroStTzStopMin OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Minute, in der die Zeitzone von Sommer auf Winterzeit in Bezug auf UTC
+ umgestellt wird."
+ ::= { wtWebGraphThermHygroTimeZone 16 }
+
+-- wtWebGraphThermHygroTimeServer Group
+----------------------------
+
+wtWebGraphThermHygroTimeServer1 OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "IP-Adresse oder Name des 1. Time Servers in ASCII"
+ ::= { wtWebGraphThermHygroTimeServer 1 }
+
+wtWebGraphThermHygroTimeServer2 OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "IP-Adresse oder Name des 2. Time Servers in ASCII"
+ ::= { wtWebGraphThermHygroTimeServer 2 }
+
+wtWebGraphThermHygroTsEnable OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(4))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Binär kodierte Bedingung:
+ Octet 1: ungenutzt
+ Octet 2: ungenutzt
+ Octet 3: ungenutzt
+ Octet 4:
+ Bit 1-7: ungenutzt
+ Bit 0 : Apply Time Server"
+ ::= { wtWebGraphThermHygroTimeServer 3 }
+
+wtWebGraphThermHygroTsSyncTime OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Die Abfrage der Timeserver erfolgt zu dieser vollen Stunde (0-23)."
+ ::= { wtWebGraphThermHygroTimeServer 4 }
+
+-- wtWebGraphThermHygroDeviceClock Group
+----------------------------
+
+wtWebGraphThermHygroClockHrs OBJECT-TYPE
+ SYNTAX INTEGER (0..23)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Uhrzeit Stunde, unter Berücksichtigung der Zeitzoneneinstellungen."
+ ::= { wtWebGraphThermHygroDeviceClock 1 }
+
+wtWebGraphThermHygroClockMin OBJECT-TYPE
+ SYNTAX INTEGER (0..59)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Uhrzeit Minute, unter Berücksichtigung der Zeitzoneneinstellungen."
+ ::= { wtWebGraphThermHygroDeviceClock 2 }
+
+wtWebGraphThermHygroClockDay OBJECT-TYPE
+ SYNTAX INTEGER (1..31)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Datum: Tag des Monats, unter Berücksichtigung der Zeitzoneneinstellungen."
+ ::= { wtWebGraphThermHygroDeviceClock 3 }
+
+wtWebGraphThermHygroClockMonth OBJECT-TYPE
+ SYNTAX INTEGER {
+ wtWebGraphThermHygroClockMonth-January(1),
+ wtWebGraphThermHygroClockMonth-February(2),
+ wtWebGraphThermHygroClockMonth-March(3),
+ wtWebGraphThermHygroClockMonth-April(4),
+ wtWebGraphThermHygroClockMonth-May(5),
+ wtWebGraphThermHygroClockMonth-June(6),
+ wtWebGraphThermHygroClockMonth-July(7),
+ wtWebGraphThermHygroClockMonth-August(8),
+ wtWebGraphThermHygroClockMonth-September(9),
+ wtWebGraphThermHygroClockMonth-October(10),
+ wtWebGraphThermHygroClockMonth-November(11),
+ wtWebGraphThermHygroClockMonth-December(12)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Datum: Monat, unter Berücksichtigung der Zeitzoneneinstellungen."
+ ::= { wtWebGraphThermHygroDeviceClock 4 }
+
+wtWebGraphThermHygroClockYear OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Datum: Jahr, unter Berücksichtigung der Zeitzoneneinstellungen."
+ ::= { wtWebGraphThermHygroDeviceClock 5 }
+
+
+-- wtWebGraphThermHygroNetwork Group
+------------------------
+
+wtWebGraphThermHygroIpAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "IP-Adresse des Webio's"
+ ::= { wtWebGraphThermHygroNetwork 1 }
+
+wtWebGraphThermHygroSubnetMask OBJECT-TYPE
+ SYNTAX IpAddress
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Subnetmask des Webio's"
+ ::= { wtWebGraphThermHygroNetwork 2 }
+
+wtWebGraphThermHygroGateway OBJECT-TYPE
+ SYNTAX IpAddress
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Gateway des Webio's"
+ ::= { wtWebGraphThermHygroNetwork 3 }
+
+wtWebGraphThermHygroDnsServer1 OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "IP-Adresse des 1. DNS Servers in ASCII"
+ ::= { wtWebGraphThermHygroNetwork 4 }
+
+wtWebGraphThermHygroDnsServer2 OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "IP-Adresse des 2. DNS Servers in ASCII"
+ ::= { wtWebGraphThermHygroNetwork 5 }
+
+wtWebGraphThermHygroAddConfig OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Zusatzkonfiguration (1=EIN):
+ Octet 1: ungenutzt
+ Octet 2: ungenutzt
+ Octet 3: ungenutzt
+ Octet 4:
+ Bit 0: BOOTP disable
+ "
+ ::= { wtWebGraphThermHygroNetwork 6 }
+
+-- wtWebGraphThermHygroHTTP Group
+--------------------------------
+
+wtWebGraphThermHygroStartup OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Legt die Startseite fest, nur eine Auswahl zulässig:
+ Octet 1: ungenutzt
+ Octet 2: ungenutzt
+ Octet 3: ungenutzt
+ Octet 4:
+ Bit 2: user.htm
+ Bit 1: home.htm
+ Bit 0: index.htm"
+ ::= { wtWebGraphThermHygroHTTP 1 }
+
+wtWebGraphThermHygroGetHeaderEnable OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Wenn freigeschaltet, wird eine Erkennungssequenz nach
+ jeder GET-Anfrage der Antwort vorangestellt:
+ Octet 1: ungenutzt
+ Octet 2: ungenutzt
+ Octet 3: ungenutzt
+ Octet 4:
+ Bit 1-7: ungenutzt
+ Bit 0 : GET Header enable"
+ ::= { wtWebGraphThermHygroHTTP 2 }
+
+wtWebGraphThermHygroHttpPort OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "HTTP Port, an den die TCP-Anfragen gesendet werden können (Default: 80)."
+ ::= { wtWebGraphThermHygroHTTP 3 }
+
+-- wtWebGraphThermHygroMail Group
+--------------------------------
+
+wtWebGraphThermHygroMailAdName OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Gerätename für die Mail-Administration."
+ ::= { wtWebGraphThermHygroMail 1 }
+
+wtWebGraphThermHygroMailReply OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Reply-Adresse für den Mailserver."
+ ::= { wtWebGraphThermHygroMail 2 }
+
+wtWebGraphThermHygroMailServer OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Name oder Ip-Adresse des Mailservers."
+ ::= { wtWebGraphThermHygroMail 3 }
+
+wtWebGraphThermHygroMailEnable OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Erlaubt das versenden von Mails:
+ Octet 1: ungenutzt
+ Octet 2: ungenutzt
+ Octet 3: ungenutzt
+ Octet 4:
+ Bit 1-7: ungenutzt
+ Bit 0 : Mail enable"
+ ::= { wtWebGraphThermHygroMail 4 }
+
+wtWebGraphThermHygroMailAuthentication OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (4))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Auswahl des Authenticationmodi:
+ die OCTETS werden bitweise interpretiert, es darf nur ein Bit gesetzt sein.
+ Bit 0 entspricht dem LSB.
+ OCTET 1: ungenutzt
+ OCTET 2: ungenutzt
+ OCTET 3: ungenutzt
+ OCTET 4: Bit 3-7: ungenutzt
+ Bit 2 : POP3 vor SMTP
+ Bit 1 : ESMTP, Authentifizierung
+ Bit 0 : SMTP, keine Authentifizierung"
+ ::= { wtWebGraphThermHygroMail 5 }
+
+wtWebGraphThermHygroMailAuthUser OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Name des Postfaches / Postfachusers."
+ ::= { wtWebGraphThermHygroMail 6 }
+
+wtWebGraphThermHygroMailAuthPassword OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Passwort zur Identifizierung des Users."
+ ::= { wtWebGraphThermHygroMail 7 }
+
+wtWebGraphThermHygroMailPop3Server OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Name oder Ip-Adresse des POP3 Servers."
+ ::= { wtWebGraphThermHygroMail 8 }
+
+-- wtWebGraphThermHygroSNMP Group
+--------------------------------
+
+wtWebGraphThermHygroSnmpCommunityStringRead OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Community string read only"
+ ::= { wtWebGraphThermHygroSNMP 1 }
+
+wtWebGraphThermHygroSnmpCommunityStringReadWrite OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Community string read / write"
+ ::= { wtWebGraphThermHygroSNMP 2 }
+
+wtWebGraphThermHygroSystemTrapManagerIP OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Name oder IP-Adresse des SNMP-Managers, der den System Trap entgegen nimmt."
+ ::= { wtWebGraphThermHygroSNMP 3 }
+
+wtWebGraphThermHygroSystemTrapEnable OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(4))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Binär kodierte Triggerbedingungen:
+ Octet 1: ungenutzt
+ Octet 2: ungenutzt
+ Octet 3: ungenutzt
+ Octet 4:
+ Bit 0: ColdStart
+ Bit 1: WarmStart
+ Bit 2-7: ungenutzt"
+ ::= { wtWebGraphThermHygroSNMP 4 }
+
+wtWebGraphThermHygroSnmpEnable OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Bit 0 schaltet SNMP frei:
+ Octet 1: ungenutzt
+ Octet 2: ungenutzt
+ Octet 3: ungenutzt
+ Octet 4:
+ Bit 1-7: ungenutzt
+ Bit 0 : SNMP enable"
+ ::= { wtWebGraphThermHygroSNMP 5 }
+
+wtWebGraphThermHygroSnmpCommunityStringTrap OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Community string der Traps."
+ ::= { wtWebGraphThermHygroSNMP 6 }
+
+
+-- wtWebGraphThermHygroUDP Group
+--------------------------------
+
+wtWebGraphThermHygroUdpPort OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Udp Port, an den die Udp-Anfragen GET Single gesendet werden können"
+ ::= { wtWebGraphThermHygroUDP 1 }
+
+wtWebGraphThermHygroUdpEnable OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Schaltet UDP frei:
+ Octet 1: ungenutzt
+ Octet 2: ungenutzt
+ Octet 3: ungenutzt
+ Octet 4:
+ Bit 1-7: ungenutzt
+ Bit 0 : UDP enable"
+ ::= { wtWebGraphThermHygroUDP 2 }
+
+-- wtWebGraphThermHygroSyslog Group
+--------------------------------
+
+wtWebGraphThermHygroSyslogServerIP OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Name oder IP-Adresse des Syslog-Servers, der die Syslog-Nachricht entgegen nimmt."
+ ::= { wtWebGraphThermHygroSyslog 1 }
+
+wtWebGraphThermHygroSyslogServerPort OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Portnummer des Syslog-Servers, default ist 514."
+ ::= { wtWebGraphThermHygroSyslog 2 }
+
+wtWebGraphThermHygroSyslogSystemMessagesEnable OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(4))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Binär kodierte Triggerbedingungen:
+ Octet 1: ungenutzt
+ Octet 2: ungenutzt
+ Octet 3: ungenutzt
+ Octet 4:
+ Bit 0: ColdStart
+ Bit 1: WarmStart
+ Bit 2: Diag Messages
+ Bit 3-7: ungenutzt"
+ ::= { wtWebGraphThermHygroSyslog 3 }
+
+wtWebGraphThermHygroSyslogEnable OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Bit 0 schaltet Syslog frei:
+ Octet 1: ungenutzt
+ Octet 2: ungenutzt
+ Octet 3: ungenutzt
+ Octet 4:
+ Bit 1-7: ungenutzt
+ Bit 0 : Syslog enable"
+ ::= { wtWebGraphThermHygroSyslog 4 }
+
+-- wtWebGraphThermHygroFTP Group
+--------------------------------
+
+wtWebGraphThermHygroFTPServerIP OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Name oder IP-Adresse des FTP-Servers, der die FTP-Nachricht entgegen nimmt."
+ ::= { wtWebGraphThermHygroFTP 1 }
+
+wtWebGraphThermHygroFTPServerControlPort OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Portnummer des Kontrollports des FTP-Servers, default ist 21."
+ ::= { wtWebGraphThermHygroFTP 2 }
+
+wtWebGraphThermHygroFTPUserName OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "FTP Loggin: Name des Anwenders."
+ ::= { wtWebGraphThermHygroFTP 3 }
+
+wtWebGraphThermHygroFTPPassword OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "FTP Loggin: Passwort des Anwenders."
+ ::= { wtWebGraphThermHygroFTP 4 }
+
+wtWebGraphThermHygroFTPAccount OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "FTP Loggin: Account-Name des Anwenderkontos."
+ ::= { wtWebGraphThermHygroFTP 5 }
+
+wtWebGraphThermHygroFTPOption OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Bit 0 schaltet den FTP Server in den Passiv-Modus,
+ der Client kontrolliert die Datenverbindung allein:
+ Octet 1: ungenutzt
+ Octet 2: ungenutzt
+ Octet 3: ungenutzt
+ Octet 4:
+ Bit 1-7: ungenutzt
+ Bit 0 : PASV enable"
+ ::= { wtWebGraphThermHygroFTP 6 }
+
+wtWebGraphThermHygroFTPEnable OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Bit 0 schaltet FTP frei:
+ Octet 1: ungenutzt
+ Octet 2: ungenutzt
+ Octet 3: ungenutzt
+ Octet 4:
+ Bit 1-7: ungenutzt
+ Bit 0 : FTP enable"
+ ::= { wtWebGraphThermHygroFTP 7 }
+
+
+-- wtWebGraphThermHygroDatalogger Group
+--------------------------------
+
+wtWebGraphThermHygroLoggerTimebase OBJECT-TYPE
+ SYNTAX INTEGER {
+ wtWebGraphThermHygroDatalogger-1Min(1),
+ wtWebGraphThermHygroDatalogger-5Min(2),
+ wtWebGraphThermHygroDatalogger-15Min(3),
+ wtWebGraphThermHygroDatalogger-60Min(4)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Zeitbasis des Dataloggers"
+ ::= { wtWebGraphThermHygroDatalogger 1 }
+
+wtWebGraphThermHygroLoggerSensorSel OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(4))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Binär kodierte Triggerbedingungen:
+ Octet 1: ungenutzt
+ Octet 2: ungenutzt
+ Octet 3: ungenutzt
+ Octet 4:
+ Bit 0 : Sensor 1
+ Bit 1 : Sensor 2
+ Bit 2-7: ungenutzt"
+ ::= { wtWebGraphThermHygroDatalogger 2 }
+
+wtWebGraphThermHygroDisplaySensorSel OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(4))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Die hier ausgewählten Sensoren werden grafisch angezeigt:
+ Octet 1: ungenutzt
+ Octet 2: ungenutzt
+ Octet 3: ungenutzt
+ Octet 4:
+ Bit 0: Sensor 1
+ Bit 1: Sensor 2
+ Bit 2-7: ungenutzt"
+ ::= { wtWebGraphThermHygroDatalogger 3 }
+
+-- Graph Sensor Color Table
+
+wtWebGraphThermHygroSensorColorTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF WtWebGraphThermHygroSensorColorEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Liste der Sensorfarben in der grafischen Darstellung."
+ ::= { wtWebGraphThermHygroDatalogger 4 }
+
+wtWebGraphThermHygroSensorColorEntry OBJECT-TYPE
+ SYNTAX WtWebGraphThermHygroSensorColorEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Nummern der Sensoren."
+ INDEX { wtWebGraphThermHygroSensorNo }
+ ::= { wtWebGraphThermHygroSensorColorTable 1 }
+
+WtWebGraphThermHygroSensorColorEntry ::= SEQUENCE {
+ wtWebGraphThermHygroSensorColor OCTET STRING
+}
+
+wtWebGraphThermHygroSensorColor OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(3))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Farbe des Sensors in der grafischen Darstellung."
+ ::= { wtWebGraphThermHygroSensorColorEntry 1 }
+
+wtWebGraphThermHygroAutoScaleEnable OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Bit 0 schaltet Vertical Auto Scale frei:
+ Octet 1: ungenutzt
+ Octet 2: ungenutzt
+ Octet 3: ungenutzt
+ Octet 4:
+ Bit 1-7: ungenutzt
+ Bit 0 : Auto Scale enable"
+ ::= { wtWebGraphThermHygroDatalogger 5 }
+
+wtWebGraphThermHygroVerticalUpperLimit OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Definiert die maximal sichtbare Temperatur für die grafische Darstellung.
+ Temperatur in Grad mit maximal 2 Nachkommastellen."
+ ::= { wtWebGraphThermHygroDatalogger 6 }
+
+wtWebGraphThermHygroVerticalLowerLimit OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Definiert die Minal sichtbare Temperatur für die grafische Darstellung.
+ Temperatur in Grad mit maximal 2 Nachkommastellen."
+ ::= { wtWebGraphThermHygroDatalogger 7 }
+
+wtWebGraphThermHygroHorizontalZoom OBJECT-TYPE
+ SYNTAX INTEGER {
+ wtWebGraphThermHygroZoom-25Min(1),
+ wtWebGraphThermHygroZoom-75Min(2),
+ wtWebGraphThermHygroZoom-5Std(3),
+ wtWebGraphThermHygroZoom-30Std(4),
+ wtWebGraphThermHygroZoom-5Tage(5),
+ wtWebGraphThermHygroZoom-25Tage(6)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Definiert den default Zoom."
+ ::= { wtWebGraphThermHygroDatalogger 8 }
+
+-- wtWebGraphThermHygroAlarm Group
+----------------------------
+
+wtWebGraphThermHygroAlarmCount OBJECT-TYPE
+ SYNTAX INTEGER (1..8)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Anzahl der unabhängigen Alarme."
+ ::= { wtWebGraphThermHygroAlarm 1 }
+
+-- Alarm Interface Table
+
+wtWebGraphThermHygroAlarmIfTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF WtWebGraphThermHygroAlarmIfEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Liste der Alarmindizes."
+ ::= { wtWebGraphThermHygroAlarm 2 }
+
+wtWebGraphThermHygroAlarmIfEntry OBJECT-TYPE
+ SYNTAX WtWebGraphThermHygroAlarmIfEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Nummern der Alarme."
+ INDEX { wtWebGraphThermHygroAlarmNo }
+ ::= { wtWebGraphThermHygroAlarmIfTable 1 }
+
+WtWebGraphThermHygroAlarmIfEntry ::= SEQUENCE {
+ wtWebGraphThermHygroAlarmNo INTEGER
+}
+
+wtWebGraphThermHygroAlarmNo OBJECT-TYPE
+ SYNTAX INTEGER (1..8)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Nummer des Alarms."
+ ::= { wtWebGraphThermHygroAlarmIfEntry 1 }
+
+-- Alarm Table
+
+wtWebGraphThermHygroAlarmTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF WtWebGraphThermHygroAlarmEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Liste der Einstellungen abhängig von der Alarmnummer."
+ ::= { wtWebGraphThermHygroAlarm 3 }
+
+wtWebGraphThermHygroAlarmEntry OBJECT-TYPE
+ SYNTAX WtWebGraphThermHygroAlarmEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Alarm-Parameter der einzelnen Alarme."
+ INDEX { wtWebGraphThermHygroAlarmNo }
+ ::= { wtWebGraphThermHygroAlarmTable 1 }
+
+WtWebGraphThermHygroAlarmEntry ::= SEQUENCE {
+ wtWebGraphThermHygroAlarmTrigger OCTET STRING,
+ wtWebGraphThermHygroAlarmMin OCTET STRING,
+ wtWebGraphThermHygroAlarmMax OCTET STRING,
+ wtWebGraphThermHygroAlarmHysteresis OCTET STRING,
+ wtWebGraphThermHygroAlarmDelay OCTET STRING,
+ wtWebGraphThermHygroAlarmInterval OCTET STRING,
+ wtWebGraphThermHygroAlarmEnable OCTET STRING,
+ wtWebGraphThermHygroAlarmEMailAddr OCTET STRING,
+ wtWebGraphThermHygroAlarmMailSubject OCTET STRING,
+ wtWebGraphThermHygroAlarmMailText OCTET STRING,
+ wtWebGraphThermHygroAlarmManagerIP OCTET STRING,
+ wtWebGraphThermHygroAlarmTrapText OCTET STRING,
+ wtWebGraphThermHygroAlarmMailOptions OCTET STRING,
+ wtWebGraphThermHygroAlarmTcpIpAddr OCTET STRING,
+ wtWebGraphThermHygroAlarmTcpPort INTEGER,
+ wtWebGraphThermHygroAlarmTcpText OCTET STRING,
+ wtWebGraphThermHygroAlarmClearMailSubject OCTET STRING,
+ wtWebGraphThermHygroAlarmClearMailText OCTET STRING,
+ wtWebGraphThermHygroAlarmClearTrapText OCTET STRING,
+ wtWebGraphThermHygroAlarmClearTcpText OCTET STRING,
+ wtWebGraphThermHygroAlarmDeltaTemp OCTET STRING,
+ wtWebGraphThermHygroAlarmRHMin OCTET STRING,
+ wtWebGraphThermHygroAlarmRHMax OCTET STRING,
+ wtWebGraphThermHygroAlarmRHHysteresis OCTET STRING,
+ wtWebGraphThermHygroAlarmAHMin OCTET STRING,
+ wtWebGraphThermHygroAlarmAHMax OCTET STRING,
+ wtWebGraphThermHygroAlarmSyslogIpAddr OCTET STRING,
+ wtWebGraphThermHygroAlarmSyslogPort INTEGER,
+ wtWebGraphThermHygroAlarmSyslogText OCTET STRING,
+ wtWebGraphThermHygroAlarmSyslogClearText OCTET STRING,
+ wtWebGraphThermHygroAlarmFtpDataPort OCTET STRING,
+ wtWebGraphThermHygroAlarmFtpFileName OCTET STRING,
+ wtWebGraphThermHygroAlarmFtpText OCTET STRING,
+ wtWebGraphThermHygroAlarmFtpClearText OCTET STRING,
+ wtWebGraphThermHygroAlarmFtpOption OCTET STRING,
+ wtWebGraphThermHygroAlarmTimerCron OCTET STRING
+
+}
+
+wtWebGraphThermHygroAlarmTrigger OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(4))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Binär kodierte Triggerbedingungen:
+ Octet 1: ungenutzt
+ Octet 2: ungenutzt
+ Octet 3:
+ Bit 0: Timer
+ Bit 1: ColdStart
+ Bit 2: WarmStart
+ Bit 3: Sensor lost
+ Bit 4-7 ungenutzt
+ Octet 4:
+ Bit 0: Sensor 1
+ Bit 1: Sensor 2
+ Bit 2-7: ungenutzt"
+ ::= { wtWebGraphThermHygroAlarmEntry 1 }
+
+wtWebGraphThermHygroAlarmMin OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Minimum Temperatur in Grad mit maximal 2 Nachkommastellen."
+ ::= { wtWebGraphThermHygroAlarmEntry 2 }
+
+wtWebGraphThermHygroAlarmMax OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Maximum Temperatur in Grad mit maximal 2 Nachkommastellen."
+ ::= { wtWebGraphThermHygroAlarmEntry 3 }
+
+wtWebGraphThermHygroAlarmHysteresis OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Bei Überschreiten der Temperatur Min+Hyst. und Unterschreiten der Temperatur Max-Hyst.
+ wird der Alarm gelöscht: pos. Temperaturdifferenz in Grad mit maximal 2 Nachkommastellen."
+ ::= { wtWebGraphThermHygroAlarmEntry 4 }
+
+wtWebGraphThermHygroAlarmDelay OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Der Alarm wird erst ausgelöst, wenn für die Dauer dieser Zeit
+ die Alarmbedingungen erfüllt sind (Zeit in Minuten)."
+ ::= { wtWebGraphThermHygroAlarmEntry 5 }
+
+wtWebGraphThermHygroAlarmInterval OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Sendeintervall von Alarmmeldungen."
+ ::= { wtWebGraphThermHygroAlarmEntry 6 }
+
+wtWebGraphThermHygroAlarmEnable OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(4))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Binär kodierte Alarmfreischaltung:
+ Octet 1: ungenutzt
+ Octet 2: ungenutzt
+ Octet 3: ungenutzt
+ Octet 4:
+ Bit 0: Mail Enable
+ Bit 1: SNMP Trap enable
+ Bit 2: TCP Client enable"
+ ::= { wtWebGraphThermHygroAlarmEntry 7 }
+
+wtWebGraphThermHygroAlarmEMailAddr OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "E-Mail Adresse, an die die Alarmmail gesendet werden soll."
+ ::= { wtWebGraphThermHygroAlarmEntry 8 }
+
+wtWebGraphThermHygroAlarmMailSubject OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Betreffzeile der Alarmmail."
+ ::= { wtWebGraphThermHygroAlarmEntry 9 }
+
+wtWebGraphThermHygroAlarmMailText OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Text der Alarmmail: <Tn> liefert die aktuelle Temperatur; n = 1..8.
+ <Z> liefert die aktuelle Zeit."
+ ::= { wtWebGraphThermHygroAlarmEntry 10 }
+
+wtWebGraphThermHygroAlarmManagerIP OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Name oder IP-Adresse des SNMP-Managers, der den Trap entgegen nimmt."
+ ::= { wtWebGraphThermHygroAlarmEntry 11 }
+
+wtWebGraphThermHygroAlarmTrapText OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Dieser Text wird im Trapbody gesendet."
+ ::= { wtWebGraphThermHygroAlarmEntry 12 }
+
+wtWebGraphThermHygroAlarmMailOptions OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(4))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Binär kodierte Optionen:
+ Octet 1: ungenutzt
+ Octet 2: ungenutzt
+ Octet 3: ungenutzt
+ Octet 4:
+ Bit 0 : Attach Thermo.csv Enable
+ Bit 1 : CSV-Data_since_last_report
+ Bit 2-7: ungenutzt"
+ ::= { wtWebGraphThermHygroAlarmEntry 13 }
+
+wtWebGraphThermHygroAlarmTcpIpAddr OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "IP-Adresse des Gerätes, dass eine TCP-Nachricht empfangen soll."
+ ::= { wtWebGraphThermHygroAlarmEntry 14 }
+
+wtWebGraphThermHygroAlarmTcpPort OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Portnummer des Gerätes, dass eine TCP-Nachricht empfangen soll."
+ ::= { wtWebGraphThermHygroAlarmEntry 15 }
+
+wtWebGraphThermHygroAlarmTcpText OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Dieser Text wird im TCP Trapbody gesendet."
+ ::= { wtWebGraphThermHygroAlarmEntry 16 }
+
+wtWebGraphThermHygroAlarmClearMailSubject OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Betreffzeile der Alarm Clear Mail."
+ ::= { wtWebGraphThermHygroAlarmEntry 17 }
+
+wtWebGraphThermHygroAlarmClearMailText OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Text der Alarm Clear Mail: <Tn> liefert die aktuelle Temperatur; n = 1..8.
+ <Z> liefert die aktuelle Zeit."
+ ::= { wtWebGraphThermHygroAlarmEntry 18 }
+
+wtWebGraphThermHygroAlarmClearTrapText OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Dieser Text wird im Trapbody gesendet."
+ ::= { wtWebGraphThermHygroAlarmEntry 19 }
+
+wtWebGraphThermHygroAlarmClearTcpText OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Dieser Text wird im TCP Trapbody gesendet."
+ ::= { wtWebGraphThermHygroAlarmEntry 20 }
+
+wtWebGraphThermHygroAlarmDeltaTemp OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Maximale Temperaturänderung in Grad/min mit maximal 2 Nachkommastellen.
+ Es wird ein Mittelwert einer Periode von 5 Minuten verglichen."
+ ::= { wtWebGraphThermHygroAlarmEntry 21 }
+
+wtWebGraphThermHygroAlarmRHMin OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Minimum rel. Feuchte in Prozent mit maximal 2 Nachkommastellen."
+ ::= { wtWebGraphThermHygroAlarmEntry 22 }
+
+wtWebGraphThermHygroAlarmRHMax OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Maximum rel.Feuchte in Prozent mit maximal 2 Nachkommastellen."
+ ::= { wtWebGraphThermHygroAlarmEntry 23 }
+
+wtWebGraphThermHygroAlarmRHHysteresis OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Hysterese rel. Feuchte in Prozent mit maximal 2 Nachkommastellen."
+ ::= { wtWebGraphThermHygroAlarmEntry 24 }
+
+wtWebGraphThermHygroAlarmAHMin OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Minimum abs. Feuchte in g/(m*m*m) mit maximal 2 Nachkommastellen."
+ ::= { wtWebGraphThermHygroAlarmEntry 25 }
+
+wtWebGraphThermHygroAlarmAHMax OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Maximum abs. Feuchte in g/(m*m*m) mit maximal 2 Nachkommastellen."
+ ::= { wtWebGraphThermHygroAlarmEntry 26 }
+
+wtWebGraphThermHygroAlarmSyslogIpAddr OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "IP-Adresse des Gerätes, dass eine Syslog-Nachricht empfangen soll."
+ ::= { wtWebGraphThermHygroAlarmEntry 27 }
+
+wtWebGraphThermHygroAlarmSyslogPort OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Portnummer des Gerätes, dass eine Syslog-Nachricht empfangen soll, default Port ist 514."
+ ::= { wtWebGraphThermHygroAlarmEntry 28 }
+
+wtWebGraphThermHygroAlarmSyslogText OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Jede Syslog-Nachricht beginnt mit einem Prioritätsschlüssel, einem Zeitstempel und der Host Ip-Nummer gemäß RFC3164.
+ Dieser Text wird im darauf folgenden Syslog-Nachrichtenteil gesendet."
+ ::= { wtWebGraphThermHygroAlarmEntry 29 }
+
+wtWebGraphThermHygroAlarmSyslogClearText OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Jede Syslog-Nachricht beginnt mit einem Prioritätsschlüssel, einem Zeitstempel und der Host Ip-Nummer gemäß RFC3164.
+ Dieser Text wird im darauf folgenden Syslog-Nachrichtenteil gesendet."
+ ::= { wtWebGraphThermHygroAlarmEntry 30 }
+
+wtWebGraphThermHygroAlarmFtpDataPort OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Lokaler Datenport: 1..65535 oder AUTO: der nächste ungenutzte Port wird automatisch zugewiesen."
+ ::= { wtWebGraphThermHygroAlarmEntry 31 }
+
+wtWebGraphThermHygroAlarmFtpFileName OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Der File Name kann auch Pfadinformationen enthalten."
+ ::= { wtWebGraphThermHygroAlarmEntry 32 }
+
+wtWebGraphThermHygroAlarmFtpText OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Dieser Text wird in die angegebene Datei geschrieben."
+ ::= { wtWebGraphThermHygroAlarmEntry 33 }
+
+wtWebGraphThermHygroAlarmFtpClearText OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Dieser Text wird in die angegebene Datei geschrieben."
+ ::= { wtWebGraphThermHygroAlarmEntry 34 }
+
+wtWebGraphThermHygroAlarmFtpOptions OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(4))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Binär kodierte Optionen, nur eine Option darf eingeschaltet sein:
+ STORE = Datei ersetzen
+ APPEND = Nachrichten ans Dateiende anhängen
+
+ Octet 1: ungenutzt
+ Octet 2: ungenutzt
+ Octet 3: ungenutzt
+ Octet 4:
+ Bit 0 : STORE
+ Bit 1 : APPEND
+ Bit 2-7: ungenutzt"
+ ::= { wtWebGraphThermHygroAlarmEntry 35 }
+
+wtWebGraphThermHygroAlarmTimerCron OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Diser Eintrag enthält 5 Leerzeichen- oder Tab-getrente Felder zur Definition von zeitgesteuerten
+ Ausgabe von Alarmnachrichten. Jedes der 5 Felder muss mit der aktuelle Zeit übereinstimmen, um
+ das Senden einer Nachricht auszulösen, Wochentag und Monatstag werden getrennt ausgewertet.
+ Feld möglicher Zahlenbereich
+ 1: Minuten 0-59
+ 2. Stunden 0-23, 0 ist Mitternacht
+ 3: Monatstag 1-31
+ 4: Monat 1-12
+ 5: Wochentag 0-6, 0 ist Sonntag
+
+ Für jedes Feld kann nun angegeben werden:
+ - eine ganze Zahl aus dem angegebenen Zahlenbereich
+ - ein Teil-Zahlenbereich (wie z.B. 1-5) innerhalb des angegebenen Zahlenbereichs
+ - eine mit Komma getrennte Liste von ganzen Zahlen oder Tei-Zahlenbereichen (wie z.B. 2,4-6,8,10)
+ - ein Stern * (deckt den gesamten erlaubten Bereich ab)
+ - ein / gibt die Schrittweite bei Teil-Zahlenbereichen an (z.B. 0-59/2 jede zweite Minute)."
+ ::= { wtWebGraphThermHygroAlarmEntry 36 }
+
+-- wtWebGraphThermHygroPorts Group
+----------------------------
+
+-- Table
+
+wtWebGraphThermHygroPortTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF WtWebGraphThermHygroPortEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Liste der Einstellungen abhängig von der Sensornummer."
+ ::= { wtWebGraphThermHygroPorts 1 }
+
+wtWebGraphThermHygroPortEntry OBJECT-TYPE
+ SYNTAX WtWebGraphThermHygroPortEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Sensor-Parameter der einzelnen Sensoren."
+ INDEX { wtWebGraphThermHygroSensorNo }
+ ::= { wtWebGraphThermHygroPortTable 1 }
+
+WtWebGraphThermHygroPortEntry ::= SEQUENCE {
+ wtWebGraphThermHygroPortName OCTET STRING,
+ wtWebGraphThermHygroPortText OCTET STRING,
+ wtWebGraphThermHygroPortOffset1 OCTET STRING,
+ wtWebGraphThermHygroPortTemperature1 OCTET STRING,
+ wtWebGraphThermHygroPortOffset2 OCTET STRING,
+ wtWebGraphThermHygroPortTemperature2 OCTET STRING,
+ wtWebGraphThermHygroPortComment OCTET STRING,
+ wtWebGraphThermHygroPortSensorSelect OCTET STRING
+}
+
+wtWebGraphThermHygroPortName OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Name des Sensors."
+ ::= { wtWebGraphThermHygroPortEntry 1 }
+
+wtWebGraphThermHygroPortText OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Beschreibung des Sensors."
+ ::= { wtWebGraphThermHygroPortEntry 2 }
+
+wtWebGraphThermHygroPortOffset1 OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Offset-Kalibrierung: Offset in Grad mit max. 2 Nachkommastellen bei Temperatur 1."
+ ::= { wtWebGraphThermHygroPortEntry 3 }
+
+wtWebGraphThermHygroPortTemperature1 OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Offset-Kalibrierung: Referenztemperatur 1 in Grad mit max. 2 Nachkommastellen."
+ ::= { wtWebGraphThermHygroPortEntry 4 }
+
+wtWebGraphThermHygroPortOffset2 OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Offset-Kalibrierung: Offset in Grad mit max. 2 Nachkommastellen bei Temperatur 2."
+ ::= { wtWebGraphThermHygroPortEntry 5 }
+
+wtWebGraphThermHygroPortTemperature2 OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Offset-Kalibrierung: Referenztemperatur 2 in Grad mit max. 2 Nachkommastellen."
+ ::= { wtWebGraphThermHygroPortEntry 6 }
+
+wtWebGraphThermHygroPortComment OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Offset-Kalibrierung: Angaben zu Datum, Referenzgerät, Operator."
+ ::= { wtWebGraphThermHygroPortEntry 7 }
+
+wtWebGraphThermHygroPortSensorSelect OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(4))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Binär kodierte Optionen für Sensor 1:
+ Octet 1: ungenutzt
+ Octet 2: ungenutzt
+ Octet 3: ungenutzt
+ Octet 4:
+ Bit 0 : PT100
+ Bit 1 : PT1000 (default)
+ Bit 2-7: ungenutzt
+
+ Binär kodierte Optionen für Sensor 2:
+ Octet 1: ungenutzt
+ Octet 2: ungenutzt
+ Octet 3: ungenutzt
+ Octet 4:
+ Bit 0 : W&T Sensor rel. Feuchte (default)
+ Bit 1 : Skalar 0-2.5V
+ Bit 2 : Disconnect
+ Bit 3-7: ungenutzt"
+ ::= { wtWebGraphThermHygroPortEntry 8 }
+
+-- wtWebGraphThermHygroManufact Group
+----------------------------
+
+wtWebGraphThermHygroMfName OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Hersteller Firmenname"
+ ::= { wtWebGraphThermHygroManufact 1 }
+
+wtWebGraphThermHygroMfAddr OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Adresse des Herstellers."
+ ::= { wtWebGraphThermHygroManufact 2 }
+
+wtWebGraphThermHygroMfHotline OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Hotline des Herstellers."
+ ::= { wtWebGraphThermHygroManufact 3 }
+
+wtWebGraphThermHygroMfInternet OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Internet-Adresse des Herstellers."
+ ::= { wtWebGraphThermHygroManufact 4 }
+
+wtWebGraphThermHygroMfDeviceTyp OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Gerätebezeichnung (Typ) des Herstellers."
+ ::= { wtWebGraphThermHygroManufact 5 }
+
+wtWebGraphThermHygroMfOrderNo OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Bestellnummer des Gerätes des Herstellers."
+ ::= { wtWebGraphThermHygroManufact 6 }
+
+-- wtWebGraphThermHygroDiag Group
+----------------------------
+
+wtWebGraphThermHygroDiagErrorCount OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Anzahl der Einträge im Fehlerspeicher."
+ ::= { wtWebGraphThermHygroDiag 1 }
+
+wtWebGraphThermHygroDiagBinaryError OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Bitweise kodierte Fehlerursachen."
+ ::= { wtWebGraphThermHygroDiag 2 }
+
+wtWebGraphThermHygroDiagErrorIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Der Wert dieser Variable wird als Index für die Ausgabe
+ eines Fehlertextes (wtWebGraphThermHygroDiagErrorMessage) verwendet.
+ Die Fehler im Speicher sind von 1 bis wtWebGraphThermHygroDiagErrorCount durchnummeriert.
+ Nach dem Schreiben einens gültigen Wertes in diese Variable kann der dazugehörige Text
+ in wtWebGraphThermHygroDiagErrorMessage ausgelesen werden."
+ ::= { wtWebGraphThermHygroDiag 3 }
+
+wtWebGraphThermHygroDiagErrorMessage OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Abhängig vom Wert wtWebGraphThermHygroDiagErrorIndex wird ein Fehlertext angezeigt."
+ ::= { wtWebGraphThermHygroDiag 4 }
+
+wtWebGraphThermHygroDiagErrorClear OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS write-only
+ STATUS mandatory
+ DESCRIPTION
+ "Durch Schreiben eine 1 in diese Variable, wird der Fehlerspeicher gelöscht."
+ ::= { wtWebGraphThermHygroDiag 5 }
+
+-- TRAP DEFINITIONS
+
+-- Diese SNMP-Traps werden gesendet, wenn die Alarmtriggerbedingungen zutreffen
+
+wtWebGraphThermHygroAlert1 TRAP-TYPE
+ ENTERPRISE wtWebGraphThermHygro
+ VARIABLES { wtWebGraphThermHygroAlarmTrapText }
+ DESCRIPTION
+ "Dieser SNMP-Trap wird generiert, wenn der Alarm 1 ausgelöst wurde,
+ das SNMP-Trap-Enable gesetzt ist und
+ SNMP in Enable freigegeben ist."
+ -- NMS trap annotation
+ --#TYPE "Thermo-Hygrometer Alarm 1"
+ --#SUMMARY "Alarm 1: %s"
+ --#ARGUMENTS {0}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ ::= 31
+
+wtWebGraphThermHygroAlert2 TRAP-TYPE
+ ENTERPRISE wtWebGraphThermHygro
+ VARIABLES { wtWebGraphThermHygroAlarmTrapText }
+ DESCRIPTION
+ "Dieser SNMP-Trap wird generiert, wenn der Alarm 2 ausgelöst wurde,
+ das SNMP-Trap-Enable gesetzt ist und
+ SNMP in Enable freigegeben ist."
+ -- NMS trap annotation
+ --#TYPE "Thermo-Hygrometer Alarm 2"
+ --#SUMMARY "Alarm 2: %s"
+ --#ARGUMENTS {0}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ ::= 32
+
+wtWebGraphThermHygroAlert3 TRAP-TYPE
+ ENTERPRISE wtWebGraphThermHygro
+ VARIABLES { wtWebGraphThermHygroAlarmTrapText }
+ DESCRIPTION
+ "Dieser SNMP-Trap wird generiert, wenn der Alarm 3 ausgelöst wurde,
+ das SNMP-Trap-Enable gesetzt ist und
+ SNMP in Enable freigegeben ist."
+ -- NMS trap annotation
+ --#TYPE "Thermo-Hygrometer Alarm 3"
+ --#SUMMARY "Alarm 3: %s"
+ --#ARGUMENTS {0}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ ::= 33
+
+wtWebGraphThermHygroAlert4 TRAP-TYPE
+ ENTERPRISE wtWebGraphThermHygro
+ VARIABLES { wtWebGraphThermHygroAlarmTrapText }
+ DESCRIPTION
+ "Dieser SNMP-Trap wird generiert, wenn der Alarm 4 ausgelöst wurde,
+ das SNMP-Trap-Enable gesetzt ist und
+ SNMP in Enable freigegeben ist."
+ -- NMS trap annotation
+ --#TYPE "Thermo-Hygrometer Alarm 4"
+ --#SUMMARY "Alarm 4: %s"
+ --#ARGUMENTS {0}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ ::= 34
+
+wtWebGraphThermHygroAlert5 TRAP-TYPE
+ ENTERPRISE wtWebGraphThermHygro
+ VARIABLES { wtWebGraphThermHygroAlarmTrapText }
+ DESCRIPTION
+ "Dieser SNMP-Trap wird generiert, wenn der Alarm 5 ausgelöst wurde,
+ das SNMP-Trap-Enable gesetzt ist und
+ SNMP in Enable freigegeben ist."
+ -- NMS trap annotation
+ --#TYPE "Thermo-Hygrometer Alarm 5"
+ --#SUMMARY "Alarm 5: %s"
+ --#ARGUMENTS {0}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ ::= 35
+
+wtWebGraphThermHygroAlert6 TRAP-TYPE
+ ENTERPRISE wtWebGraphThermHygro
+ VARIABLES { wtWebGraphThermHygroAlarmTrapText }
+ DESCRIPTION
+ "Dieser SNMP-Trap wird generiert, wenn der Alarm 6 ausgelöst wurde,
+ das SNMP-Trap-Enable gesetzt ist und
+ SNMP in Enable freigegeben ist."
+ -- NMS trap annotation
+ --#TYPE "Thermo-Hygrometer Alarm 6"
+ --#SUMMARY "Alarm 6: %s"
+ --#ARGUMENTS {0}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ ::= 36
+
+wtWebGraphThermHygroAlert7 TRAP-TYPE
+ ENTERPRISE wtWebGraphThermHygro
+ VARIABLES { wtWebGraphThermHygroAlarmTrapText }
+ DESCRIPTION
+ "Dieser SNMP-Trap wird generiert, wenn der Alarm 7 ausgelöst wurde,
+ das SNMP-Trap-Enable gesetzt ist und
+ SNMP in Enable freigegeben ist."
+ -- NMS trap annotation
+ --#TYPE "Thermo-Hygrometer Alarm 7"
+ --#SUMMARY "Alarm 7: %s"
+ --#ARGUMENTS {0}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ ::= 37
+
+wtWebGraphThermHygroAlert8 TRAP-TYPE
+ ENTERPRISE wtWebGraphThermHygro
+ VARIABLES { wtWebGraphThermHygroAlarmTrapText }
+ DESCRIPTION
+ "Dieser SNMP-Trap wird generiert, wenn der Alarm 8 ausgelöst wurde,
+ das SNMP-Trap-Enable gesetzt ist und
+ SNMP in Enable freigegeben ist."
+ -- NMS trap annotation
+ --#TYPE "Thermo-Hygrometer Alarm 8"
+ --#SUMMARY "Alarm 8: %s"
+ --#ARGUMENTS {0}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ ::= 38
+
+wtWebGraphThermHygroAlert9 TRAP-TYPE
+ ENTERPRISE wtWebGraphThermHygro
+ VARIABLES { wtWebGraphThermHygroAlarmClearTrapText }
+ DESCRIPTION
+ "Dieser SNMP-Trap wird generiert, wenn der Alarm 1 gelöscht wurde,
+ das SNMP-Trap-Enable gesetzt ist und
+ SNMP in Enable freigegeben ist."
+ -- NMS trap annotation
+ --#TYPE "Thermo-Hygrometer Release Alarm 1"
+ --#SUMMARY "Release Alarm 1: %s"
+ --#ARGUMENTS {0}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ ::= 91
+
+wtWebGraphThermHygroAlert10 TRAP-TYPE
+ ENTERPRISE wtWebGraphThermHygro
+ VARIABLES { wtWebGraphThermHygroAlarmClearTrapText }
+ DESCRIPTION
+ "Dieser SNMP-Trap wird generiert, wenn der Alarm 2 gelöscht wurde,
+ das SNMP-Trap-Enable gesetzt ist und
+ SNMP in Enable freigegeben ist."
+ -- NMS trap annotation
+ --#TYPE "Thermo-Hygrometer Release Alarm 2"
+ --#SUMMARY "Release Alarm 2: %s"
+ --#ARGUMENTS {0}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ ::= 92
+
+wtWebGraphThermHygroAlert11 TRAP-TYPE
+ ENTERPRISE wtWebGraphThermHygro
+ VARIABLES { wtWebGraphThermHygroAlarmClearTrapText }
+ DESCRIPTION
+ "Dieser SNMP-Trap wird generiert, wenn der Alarm 3 gelöscht wurde,
+ das SNMP-Trap-Enable gesetzt ist und
+ SNMP in Enable freigegeben ist."
+ -- NMS trap annotation
+ --#TYPE "Thermo-Hygrometer Release Alarm 3"
+ --#SUMMARY "Release Alarm 3: %s"
+ --#ARGUMENTS {0}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ ::= 93
+
+wtWebGraphThermHygroAlert12 TRAP-TYPE
+ ENTERPRISE wtWebGraphThermHygro
+ VARIABLES { wtWebGraphThermHygroAlarmClearTrapText }
+ DESCRIPTION
+ "Dieser SNMP-Trap wird generiert, wenn der Alarm 4 gelöscht wurde,
+ das SNMP-Trap-Enable gesetzt ist und
+ SNMP in Enable freigegeben ist."
+ -- NMS trap annotation
+ --#TYPE "Thermo-Hygrometer Release Alarm 4"
+ --#SUMMARY "Release Alarm 4: %s"
+ --#ARGUMENTS {0}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ ::= 94
+
+wtWebGraphThermHygroAlert13 TRAP-TYPE
+ ENTERPRISE wtWebGraphThermHygro
+ VARIABLES { wtWebGraphThermHygroAlarmClearTrapText }
+ DESCRIPTION
+ "Dieser SNMP-Trap wird generiert, wenn der Alarm 5 gelöscht wurde,
+ das SNMP-Trap-Enable gesetzt ist und
+ SNMP in Enable freigegeben ist."
+ -- NMS trap annotation
+ --#TYPE "Thermo-Hygrometer Release Alarm 5"
+ --#SUMMARY "Release Alarm 5: %s"
+ --#ARGUMENTS {0}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ ::= 95
+
+wtWebGraphThermHygroAlert14 TRAP-TYPE
+ ENTERPRISE wtWebGraphThermHygro
+ VARIABLES { wtWebGraphThermHygroAlarmClearTrapText }
+ DESCRIPTION
+ "Dieser SNMP-Trap wird generiert, wenn der Alarm 6 gelöscht wurde,
+ das SNMP-Trap-Enable gesetzt ist und
+ SNMP in Enable freigegeben ist."
+ -- NMS trap annotation
+ --#TYPE "Thermo-Hygrometer Release Alarm 6"
+ --#SUMMARY "Release Alarm 6: %s"
+ --#ARGUMENTS {0}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ ::= 96
+
+wtWebGraphThermHygroAlert15 TRAP-TYPE
+ ENTERPRISE wtWebGraphThermHygro
+ VARIABLES { wtWebGraphThermHygroAlarmClearTrapText }
+ DESCRIPTION
+ "Dieser SNMP-Trap wird generiert, wenn der Alarm 7 gelöscht wurde,
+ das SNMP-Trap-Enable gesetzt ist und
+ SNMP in Enable freigegeben ist."
+ -- NMS trap annotation
+ --#TYPE "Thermo-Hygrometer Release Alarm 7"
+ --#SUMMARY "Release Alarm 7: %s"
+ --#ARGUMENTS {0}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ ::= 97
+
+wtWebGraphThermHygroAlert16 TRAP-TYPE
+ ENTERPRISE wtWebGraphThermHygro
+ VARIABLES { wtWebGraphThermHygroAlarmClearTrapText }
+ DESCRIPTION
+ "Dieser SNMP-Trap wird generiert, wenn der Alarm 8 gelöscht wurde,
+ das SNMP-Trap-Enable gesetzt ist und
+ SNMP in Enable freigegeben ist."
+ -- NMS trap annotation
+ --#TYPE "Thermo-Hygrometer Release Alarm 8"
+ --#SUMMARY "Release Alarm 8: %s"
+ --#ARGUMENTS {0}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ ::= 98
+
+wtWebGraphThermHygroAlertDiag TRAP-TYPE
+ ENTERPRISE wtWebGraphThermHygro
+ VARIABLES {
+ wtWebGraphThermHygroDiagErrorIndex,
+ wtWebGraphThermHygroDiagErrorMessage
+ }
+ DESCRIPTION
+ "Dieser SNMP-Trap wird generiert, wenn eine Diagnose/Error-Message ausgelöst wurde,
+ das SNMP-Trap-Enable gesetzt ist und
+ SNMP in Enable freigegeben ist."
+ -- NMS trap annotation
+ --#TYPE "Thermo-Hygrometer Diagnose Error"
+ --#SUMMARY "Diagnose error index: %d, Message: %s."
+ --#ARGUMENTS {0,1}
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 99
+ --#STATE DEGRADED
+ ::= 110
+
+END
|