commit98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch)
tree9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/ubiquoss/UBQS-AFSMGR-MIB
downloadmibs-main.tar.gz
mibs-main.zip
Initial commitHEADmain
Diffstat (limited to 'MIBS/ubiquoss/UBQS-AFSMGR-MIB')
-rw-r--r--MIBS/ubiquoss/UBQS-AFSMGR-MIB1024
1 files changed, 1024 insertions, 0 deletions
diff --git a/MIBS/ubiquoss/UBQS-AFSMGR-MIB b/MIBS/ubiquoss/UBQS-AFSMGR-MIB
new file mode 100644
index 0000000..4eeaa68
--- /dev/null
+++ b/MIBS/ubiquoss/UBQS-AFSMGR-MIB
@@ -0,0 +1,1024 @@
+--
+-- UBQS-AFSMGR-MIB.my
+-- MIB generated by MG-SOFT Visual MIB Builder Version 3.0 Build 271
+-- Monday, April 12, 2010
+--
+
+ UBQS-AFSMGR-MIB DEFINITIONS ::= BEGIN
+
+ IMPORTS
+ sysObjectID, sysContact, sysName, sysLocation, ifIndex
+ FROM RFC1213-MIB
+ IpAddress, Integer32, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE
+ FROM SNMPv2-SMI
+ DisplayString, RowStatus
+ FROM SNMPv2-TC
+ ubiMgmtv2
+ FROM UBQS-SMI;
+
+
+ ubiAFSMGREventMIB MODULE-IDENTITY
+ LAST-UPDATED "201004120000Z"
+ ORGANIZATION "Ubiquoss Corp."
+ CONTACT-INFO
+ " Ubiquoss
+ Customer Service
+
+ Postal: 24F Milennium B/D,
+ 467-12, Dogok-Dong,
+ GangNam-Gu, Seoul 135-270
+ Korea
+
+ Tel: 82-2-2190-3100"
+ DESCRIPTION
+ "AFSMGR Event Group"
+ ::= { ubiMgmtv2 7 }
+
+
+
+--
+-- Node definitions
+--
+
+ -- 1.3.6.1.4.1.236.4.1.7.2.1
+ currentAlarmTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CurrentAlarmEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { ubiAFSMGREventMIB 1 }
+
+ -- 1.3.6.1.4.1.236.4.1.7.2.1.1
+ currentAlarmEntry OBJECT-TYPE
+ SYNTAX CurrentAlarmEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Description."
+ INDEX { AlarmIndex }
+ ::= { currentAlarmTable 1 }
+
+ CurrentAlarmEntry ::=
+ SEQUENCE {
+ alarmIndex
+ Integer32,
+ alarmId
+ DisplayString,
+ alarmType
+ INTEGER,
+ alarmSeverity
+ INTEGER,
+ alarmPhysicalLoc
+ DisplayString,
+ alarmLogicalLoc
+ DisplayString,
+ alarmCurStatus
+ Integer32,
+ alarmAuxinfo
+ DisplayString,
+ alarmDateTime
+ DisplayString,
+ alarmStatus
+ Integer32
+ }
+
+ alarmIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "current Alarm index."
+ ::= { currentAlarmEntry 1 }
+
+ alarmId OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description"
+ ::= { currentAlarmEntry 2 }
+
+ alarmType OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ equipment(1),
+ communications(2),
+ qos(3),
+ processing(4),
+ environment(5)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description
+ 1 : equipment
+ 2 : communications
+ 3 : QoS
+ 4 : processing
+ 5 : environment
+ "
+ ::= { currentAlarmEntry 3 }
+
+ alarmSeverity OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ critical(1),
+ major(2),
+ minor(3),
+ warning(4),
+ indeterminate(5)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description
+ 1 : critical
+ 2 : major
+ 3 : minor
+ 4 : warning
+ 5 : indeterminate
+ "
+ ::= { currentAlarmEntry 4 }
+
+ alarmPhysicalLoc OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description"
+ ::= { currentAlarmEntry 5 }
+
+ alarmLogicalLoc OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description"
+ ::= { currentAlarmEntry 6 }
+
+ alarmCurStatus OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description"
+ ::= { currentAlarmEntry 7 }
+
+ alarmAuxinfo OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description"
+ ::= { currentAlarmEntry 8 }
+
+ alarmDateTime OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description"
+ ::= { currentAlarmEntry 9 }
+
+ alarmStatus OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description"
+ ::= { currentAlarmEntry 10 }
+
+--
+-- eventLogTable
+--
+ eventLogTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EventLogEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { ubiAFSMGREventMIB 2 }
+
+ eventLogEntry OBJECT-TYPE
+ SYNTAX EventLogEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Description."
+ INDEX { EventIndex }
+ ::= { eventLogTable 1 }
+
+ EventLogEntry ::=
+ SEQUENCE {
+ eventIndex
+ Integer32,
+ eventId
+ DisplayString,
+ eventType
+ INTEGER,
+ eventSeverity
+ INTEGER,
+ eventValue
+ DisplayString,
+ eventDateTime
+ DisplayString,
+ eventStatus
+ Integer32
+ }
+
+ eventIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description"
+ ::= { eventLogEntry 1 }
+
+ eventId OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description"
+ ::= { eventLogEntry 2 }
+
+ eventType OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ equipment(1),
+ communications(2),
+ qos(3),
+ processing(4),
+ environment(5)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description
+ 1 : equipment
+ 2 : communications
+ 3 : QoS
+ 4 : processing
+ 5 : environment
+ "
+ ::= { eventLogEntry 3 }
+
+ eventSeverity OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ critical(1),
+ major(2),
+ minor(3),
+ warning(4),
+ indeterminate(5)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description
+ 1 : critical
+ 2 : major
+ 3 : minor
+ 4 : warning
+ 5 : indeterminate
+ "
+ ::= { eventLogEntry 4 }
+
+ eventValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description"
+ ::= { eventLogEntry 5 }
+
+ eventDateTime OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description"
+ ::= { eventLogEntry 6 }
+
+ eventStatus OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description"
+ ::= { eventLogEntry 7 }
+
+
+--
+-- afsmgrEventManagerTrap
+--
+ afsmgrEventManagerTrap OBJECT IDENTIFIER ::= { ubiAFSMGREventMIB 3 }
+
+ sysWarmStartNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "System Warm-Start Notification."
+ ::= { afsmgrEventManagerTrap 1 }
+
+ sysColdStartNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "System Cold-Start Notification."
+ ::= { afsmgrEventManagerTrap 2 }
+
+ linkUpNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Link Up Notification."
+ ::= { afsmgrEventManagerTrap 3 }
+
+ linkDownNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Link Down Notification."
+ ::= { afsmgrEventManagerTrap 4 }
+
+ cpuOverloadFallingNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "CPU Overload Falling Notification."
+ ::= { afsmgrEventManagerTrap 5 }
+
+ cpuOverloadRisingNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "CPU Overload Rising Notification."
+ ::= { afsmgrEventManagerTrap 6 }
+
+ gbicOperNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Gbic Equip/Unequip Operation Notification."
+ ::= { afsmgrEventManagerTrap 7 }
+
+ memoryOverloadNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Memory Overload Notification."
+ ::= { afsmgrEventManagerTrap 8 }
+
+ slotOperNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Slot Equip/Unequip Operation Notification."
+ ::= { afsmgrEventManagerTrap 9 }
+
+ tempLowNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Temperature Low Alarm Notification."
+ ::= { afsmgrEventManagerTrap 10 }
+
+ tempHighNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Temperature High Alarm Notification."
+ ::= { afsmgrEventManagerTrap 11 }
+
+ fanAlarmNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Fan Alarm Notification."
+ ::= { afsmgrEventManagerTrap 12 }
+
+ fmuEquipStatusNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Fan Module Unit Equip/Unequip Status Notification."
+ ::= { afsmgrEventManagerTrap 13 }
+
+ psuAlarmNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Power Alarm Notification."
+ ::= { afsmgrEventManagerTrap 14 }
+
+ psuEquipStatusNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Power Supply Unit Equip/Unequip Status Notification."
+ ::= { afsmgrEventManagerTrap 15 }
+
+ portAdminNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Port Administration Status Notification."
+ ::= { afsmgrEventManagerTrap 16 }
+
+ fanOperStatusNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Fan Operational Status Notification."
+ ::= { afsmgrEventManagerTrap 17 }
+
+ rmonRisingNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Rmon Rising Notification."
+ ::= { afsmgrEventManagerTrap 18 }
+
+ rmonFallingNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Rmon Falling Notification."
+ ::= { afsmgrEventManagerTrap 19 }
+
+ portSLDNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Port Self-Loop Detection Notification."
+ ::= { afsmgrEventManagerTrap 20 }
+
+
+ remoteConnection NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Remote connection Notification."
+ ::= { afsmgrEventManagerTrap 30 }
+
+ ponDriftWindowNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Onu Drift Window Notification."
+ ::= { afsmgrEventManagerTrap 41 }
+
+ ponGemChannelLossNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Loss of GEM channel delineation Notification."
+ ::= { afsmgrEventManagerTrap 42 }
+
+ ponAckLossNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Loss of acknowledge with ONUi Notification."
+ ::= { afsmgrEventManagerTrap 43 }
+
+ ponSigDegradeNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Signal Degraded of ONUi Notification."
+ ::= { afsmgrEventManagerTrap 44 }
+
+ ponSigFailNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Signal Fail of ONUi Notification."
+ ::= { afsmgrEventManagerTrap 45 }
+
+ ponPhysEquipErrNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Physical Equipment Error of ONUi Notification."
+ ::= { afsmgrEventManagerTrap 46 }
+
+ ponKeySyncLossNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Loss of Key sync with ONUi Notification."
+ ::= { afsmgrEventManagerTrap 47 }
+
+ ponTransIfWarmNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Transmission Interference Warning Notification."
+ ::= { afsmgrEventManagerTrap 48 }
+
+ ponTransIfAlarmNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Transmission Interference Alarm Notification."
+ ::= { afsmgrEventManagerTrap 49 }
+
+ ponRemoDefectIndNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Remote Defect Indication of ONUi Notification."
+ ::= { afsmgrEventManagerTrap 50 }
+
+ onuOperStatusNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Onu Operation Status Notification."
+ ::= { afsmgrEventManagerTrap 51 }
+
+ oltAlarmNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Olt Alarm Notification."
+ ::= { afsmgrEventManagerTrap 52 }
+
+ oltLinkFaultNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Olt Link Fault Notification."
+ ::= { afsmgrEventManagerTrap 53 }
+
+ ontDyingGaspNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Ont Dying Gasp Notification."
+ ::= { afsmgrEventManagerTrap 54 }
+
+ ponLinkStatusNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Pon Link Status Notification."
+ ::= { afsmgrEventManagerTrap 55 }
+
+ linkLoopbackTestNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Link Loopback Test Notification."
+ ::= { afsmgrEventManagerTrap 57 }
+
+ ponOltOperStatusNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Pon Olt Oper Status Notification."
+ ::= { afsmgrEventManagerTrap 68 }
+
+ ponOltAdminStatusNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Pon Olt Administrator Status Notification."
+ ::= { afsmgrEventManagerTrap 69 }
+
+ ponOnuAdminStatusNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Onu Admin Status Notification."
+ ::= { afsmgrEventManagerTrap 70 }
+
+ ponOnuRegisterSubMacNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Onu Subscriber Mac Registration Notification."
+ ::= { afsmgrEventManagerTrap 71 }
+
+ linkLoopbackTestFailNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Link Loopback Test Fail Notification."
+ ::= { afsmgrEventManagerTrap 73 }
+
+ ponOnuRegOverloadNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Pon Onu Register Overload Notification. (onu too many registration)"
+ ::= { afsmgrEventManagerTrap 93 }
+
+ ponLinkRegNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Pon Link Register Notification."
+ ::= { afsmgrEventManagerTrap 96 }
+
+ ponOnuLoopDetectNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Onu Loop Detect Notification."
+ ::= { afsmgrEventManagerTrap 97 }
+
+
+ ponOltImageUpgrageNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Olt Image Upgrade Notification."
+ ::= { afsmgrEventManagerTrap 98 }
+
+ ponOltImageUpgrageFailNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Olt Image Upgrade Fail Notification."
+ ::= { afsmgrEventManagerTrap 99 }
+
+ onuImageUpgradeNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "ONU Image Upgrade Notification."
+ ::= { afsmgrEventManagerTrap 100 }
+
+ onuImageUpgradeFailNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "ONU Image Upgrade Fail Notification."
+ ::= { afsmgrEventManagerTrap 101 }
+
+ onuLdShutdownNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "ONU LD shutdown Notification."
+ ::= { afsmgrEventManagerTrap 102 }
+
+ ponUnadminMacRegNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Unadmin Mac-address Register Notification."
+ ::= { afsmgrEventManagerTrap 103 }
+
+ ponDupMacRegNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Duplicated Mac-address Register Notification."
+ ::= { afsmgrEventManagerTrap 104 }
+
+ ponOnuTypeMismatchNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Onu Type Mismatch Notification."
+ ::= { afsmgrEventManagerTrap 105 }
+
+ ponOltDyingGaspNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Pon Olt DyingGasp Notification."
+ ::= { afsmgrEventManagerTrap 106 }
+
+ ponOltCableDownNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Olt Cable Down Notification."
+ ::= { afsmgrEventManagerTrap 107 }
+
+ ponPMCcrc32MonitorNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "PMC CRC32 Monitor Notification."
+ ::= { afsmgrEventManagerTrap 108 }
+
+ imageUpDownloadStatusNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Image Up/Download Status Notification."
+ ::= { afsmgrEventManagerTrap 109 }
+
+ imageUpDownloadFailNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Image Up/Download Fail Notification."
+ ::= { afsmgrEventManagerTrap 110 }
+
+ configUpDownloadStatusNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Config Up/Download Status Notification."
+ ::= { afsmgrEventManagerTrap 111 }
+
+ sysRebootMaxTempNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "System Reboot by Max Temperature Notification."
+ ::= { afsmgrEventManagerTrap 112 }
+
+ ponRogueOnuLdShutdown NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Rogue Onu Ld Shutdown Notification."
+ ::= { afsmgrEventManagerTrap 113 }
+
+ scuOperStatusNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "SCU Operation Status Notification."
+ ::= { afsmgrEventManagerTrap 114 }
+
+ configUpDownloadFailNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Config Up/Download Fail Notification."
+ ::= { afsmgrEventManagerTrap 115 }
+
+ ponOntRxPowerStatusNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Pon Ont Rx-optical-alarm Notification."
+ ::= { afsmgrEventManagerTrap 116 }
+
+ ponOltRxPowerStatusNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Pon Olt Rx-optical-alarm Notification."
+ ::= { afsmgrEventManagerTrap 117 }
+
+ ponOntTxPowerStatusNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Pon Ont Tx-optical-alarm Notification."
+ ::= { afsmgrEventManagerTrap 118 }
+
+ ponOntTemperatureStatusNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Pon Ont Temperature-alarm Notification."
+ ::= { afsmgrEventManagerTrap 119 }
+
+
+ ponOntVoltageStatusNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Pon Ont Voltage-alarm Notification."
+ ::= { afsmgrEventManagerTrap 120 }
+
+ ponOntBiasStatusNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Pon Ont Bias-alarm Notification."
+ ::= { afsmgrEventManagerTrap 121 }
+
+ ponOltRedSlaveFaultNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Pon Olt Redundancy Slave Link Fault Notification."
+ ::= { afsmgrEventManagerTrap 122 }
+
+ ponOltRedSwitchoverNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Pon Olt Redundancy Switchover Notification."
+ ::= { afsmgrEventManagerTrap 123 }
+
+ ponOnuOpticRxPowerOnusNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Pon Onus Low Optic Rx Power Notification."
+ ::= { afsmgrEventManagerTrap 124 }
+
+ ponOnuDownThresholdNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Pon Onu Down Threshold Notification."
+ ::= { afsmgrEventManagerTrap 127 }
+
+ ponOnuFanStatusNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Pon Onu Fan Status Notification."
+ ::= { afsmgrEventManagerTrap 128 }
+
+ ExternalACAlarm NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "External AC alarm"
+ ::= { afsmgrEventManagerTrap 129 }
+
+ ExternalUnitAlarm NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "External unit alarm."
+ ::= { afsmgrEventManagerTrap 130 }
+
+ ponLoopCntThresholdNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Loop-Count-Threshold-alarm Notification."
+ ::= { afsmgrEventManagerTrap 131 }
+
+ scuUnequipNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "scu unequip alarm"
+ ::= { afsmgrEventManagerTrap 132 }
+
+ liuUnequipNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "liu unequip alarm"
+ ::= { afsmgrEventManagerTrap 133 }
+
+ fmuUnequipNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "fmu unequip alarm"
+ ::= { afsmgrEventManagerTrap 134 }
+
+ ponOltLineCodeErrorMonitorNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "OLT line code errors monitor Notification"
+ ::= { afsmgrEventManagerTrap 135 }
+
+ ponOltAlignmentErrorMonitorNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "OLT alignment errors monitor Notification"
+ ::= { afsmgrEventManagerTrap 136 }
+
+ scuEjectorAlarmNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "SCU ejector alarm Notification"
+ ::= { afsmgrEventManagerTrap 137 }
+
+ systemCheckAlarm NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "EMS System Check Monitor Notification"
+ ::= { afsmgrEventManagerTrap 138 }
+
+ ponOnuRegThreshOverNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Pon Onu Registration Threshold Over Notification"
+ ::= { afsmgrEventManagerTrap 139 }
+
+ dcTempHighNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Dc Board Temperature High Threshold Notification"
+ ::= { afsmgrEventManagerTrap 140 }
+
+ dcTempLowNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Dc Board Temperature Low Threshold Notification"
+ ::= { afsmgrEventManagerTrap 141 }
+
+ humidityHighNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Mainboard Humidity High Threshold Notification"
+ ::= { afsmgrEventManagerTrap 142 }
+
+ humidityLowNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Mainboard Humidity Low Threshold Notification"
+ ::= { afsmgrEventManagerTrap 143 }
+
+ dcHumidityHighNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Dc Board Humidity High Threshold Notification"
+ ::= { afsmgrEventManagerTrap 144 }
+
+ dcHumidityLowNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Dc Board Humidity Low Threshold Notification"
+ ::= { afsmgrEventManagerTrap 145 }
+
+ sysRebootMaxDcTempNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "System Reboot by Max Dc Board Temperature Notification."
+ ::= { afsmgrEventManagerTrap 146 }
+
+ sysRebootMaxHumidNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "System Reboot by Max Humidity Notification."
+ ::= { afsmgrEventManagerTrap 147 }
+
+ sysRebootMaxDcHumidNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "System Reboot by Max Dc Board Humidity Notification."
+ ::= { afsmgrEventManagerTrap 148 }
+
+ fanSpeedHighNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Fan Speed High Notification."
+ ::= { afsmgrEventManagerTrap 149 }
+
+ psuUnequipNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Psu Unequip Notification."
+ ::= { afsmgrEventManagerTrap 150 }
+
+ doorOpenAlarmNoti NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "Door Open Monitor Notification"
+ ::= { afsmgrEventManagerTrap 151 }
+
+ ExternalMajorAlarm NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "External Power Major Alarm."
+ ::= { afsmgrEventManagerTrap 152 }
+
+
+ Piu10gFanFailAlarm NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
+ STATUS current
+ DESCRIPTION
+ "10G PIU Fan Fail Alarm."
+ ::= { afsmgrEventManagerTrap 157 }
+
+
+