Initial commitHEADmain
Diffstat (limited to 'MIBS/transition/TN-Y1564-MIB')
-rw-r--r--MIBS/transition/TN-Y1564-MIB601
1 files changed, 601 insertions, 0 deletions
diff --git a/MIBS/transition/TN-Y1564-MIB b/MIBS/transition/TN-Y1564-MIB
new file mode 100644
index 0000000..f8c2440
--- /dev/null
+++ b/MIBS/transition/TN-Y1564-MIB
@@ -0,0 +1,601 @@
+-- *****************************************************************
+-- TN-Y1564-MIB.my : TN Y.1564 OAM MIB
+--
+-- Author : Krish
+--
+-- Copyright (c) 2014 by Transition Networks, Inc.
+-- All rights reserved.
+--
+-- *************************************************************************************************
+--
+
+TN-Y1564-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ MODULE-IDENTITY, OBJECT-TYPE, Integer32 FROM SNMPv2-SMI
+ DisplayString, RowStatus, TruthValue FROM SNMPv2-TC
+ SnmpAdminString FROM SNMP-FRAMEWORK-MIB
+ tnProducts FROM TRANSITION-SMI
+ InetAddressType,InetAddress FROM INET-ADDRESS-MIB
+ MacAddress FROM SNMPv2-TC
+ ;
+
+tnY1564MIB MODULE-IDENTITY
+ LAST-UPDATED "201408220000Z"
+ ORGANIZATION "Transition Networks, Inc."
+ CONTACT-INFO
+ " Transition Networks
+ Technical Support
+ 10900 Red Circle Drive
+ Minnetonka, MN 55343 USA
+ Tel: +1-800-526-9267
+
+ E-mail: techsupport@transition.com"
+ DESCRIPTION
+ "The MIB provides functionalities for system user management in TN modules."
+ REVISION "201408220000Z"
+ DESCRIPTION
+ "Initial Revision of this module"
+ ::= { tnProducts 154 }
+
+
+tnY1564MIBNotifications OBJECT IDENTIFIER ::= { tnY1564MIB 1 }
+tnY1564MIBObjects OBJECT IDENTIFIER ::= { tnY1564MIB 2 }
+tnY1564MIBConformance OBJECT IDENTIFIER ::= { tnY1564MIB 3 }
+
+
+--
+-- sub Objects list
+--
+tnY1564CfgMgmt OBJECT IDENTIFIER ::= { tnY1564MIBObjects 1 }
+tnY1564ReportMgmt OBJECT IDENTIFIER ::= { tnY1564MIBObjects 2 }
+
+tnY1564ProfileTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TnY1564ProfileEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table provides configuration of SOAM Maintenance Point.
+ "
+ ::= { tnY1564CfgMgmt 1 }
+
+tnY1564ProfileEntry OBJECT-TYPE
+ SYNTAX TnY1564ProfileEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A entry in the table represents a configuration for local SOAM."
+ INDEX { IMPLIED tnY1564ProfileName }
+ ::= { tnY1564ProfileTable 1 }
+
+TnY1564ProfileEntry ::=
+ SEQUENCE{
+ tnY1564ProfileName SnmpAdminString,
+ tnY1564ProfileDescription DisplayString,
+ tnY1564DuelEnded TruthValue,
+ tnY1564DstOamAware TruthValue,
+ tnY1564TrafficType INTEGER,
+ tnY1564MegLevel INTEGER,
+ tnY1564FrameSize INTEGER,
+ tnY1564UserFrameSize INTEGER,
+ tnY1564DwellTime INTEGER,
+ tnY1564SacFLR INTEGER,
+ tnY1564SacFTD INTEGER,
+ tnY1564SacFDV INTEGER,
+ tnY1564CirEnable TruthValue,
+ tnY1564CirStepDuration INTEGER,
+ tnY1564CirDmInterval INTEGER,
+ tnY1564CirStepCount INTEGER,
+ tnY1564EirEnable TruthValue,
+ tnY1564EirDuration INTEGER,
+ tnY1564EirDmInterval INTEGER,
+ tnY1564TrafficPolicingEnable TruthValue,
+ tnY1564TrafficPolicingDuration INTEGER,
+ tnY1564TrafficPolicingDmInterval INTEGER,
+ tnY1564PerfTestEnable TruthValue,
+ tnY1564PerfTestDuration INTEGER,
+ tnY1564PerfTestUserDuration INTEGER,
+ tnY1564PerfTestDmInterval INTEGER,
+ tnY1564ProfileStatus RowStatus
+ }
+
+tnY1564ProfileName OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The name, ASCII range 33-126, of this table."
+ ::= { tnY1564ProfileEntry 1 }
+
+tnY1564ProfileDescription OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..127))
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The description of this table."
+ ::= { tnY1564ProfileEntry 2 }
+
+tnY1564DuelEnded OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "For future use."
+ ::= { tnY1564ProfileEntry 3 }
+
+tnY1564DstOamAware OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "When set, switch transmits Y.1731 DMM frames for delay measurements
+ and Y.1731 1DM frames when this is cleared. When Traffic Type is 'Y.1731 OAM',
+ switch transmits Y.1731 LBM frames as background traffic when DST is
+ configured as OAM-aware, and Y.1731 TST frames when not."
+ ::= { tnY1564ProfileEntry 4 }
+
+tnY1564TrafficType OBJECT-TYPE
+ SYNTAX INTEGER {
+ y1731Oam(1),
+ simCustomer(2)
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION "
+ When set to 'Y.1731 OAM', this switch transmits Y.1731
+ OAM PDUs as background traffic, and DST is OAM-aware
+ determines the PDU type. In the current version of the
+ software, only one ECE can be tested at a time in this mode.
+ When set to 'Simulated Customer', the software will generate
+ a traffic-pattern per ECE that will hit the ECE, and use
+ the ECE's counters to determine PASS/FAIL criteria.Besides
+ supporting simultaneous test of multiple ECEs,
+ 'Simulated Customer' has the advantage that the tester can
+ see directly from the report if she has configured ECEs wrongly,
+ since the report will show per-ECE counters and fail if an ECE
+ under test is not hit as expected by the traffic pattern."
+ ::= { tnY1564ProfileEntry 5 }
+
+tnY1564MegLevel OBJECT-TYPE
+ SYNTAX INTEGER {
+ one(1),
+ two(2),
+ three(3),
+ four(4),
+ five(5),
+ six(6),
+ seven(7)
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION "
+ The MEG level used in generated Y.1731 OAM frames (both LBM/TST and DMM/1DM)."
+ ::= { tnY1564ProfileEntry 6 }
+
+tnY1564FrameSize OBJECT-TYPE
+ SYNTAX INTEGER {
+ bytes64(1),
+ bytes128(2),
+ bytes256(3),
+ bytes512(4),
+ bytes1024(5),
+ bytes1280(6),
+ bytes1518(7),
+ mtu(8),
+ userDefined(9)
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION "
+ Selects the frame size of the background traffic. The frame size
+ does not include possible C-tag(s) added to match the ECE. Besides
+ standard frame sizes there are two custom selections:
+
+ MTU - The UNI's MTU will be used for the background traffic.
+ User-defined - custom specification of a frame size of the background traffic.
+ Valid range is 64 to 10236 bytes.
+ "
+ ::= { tnY1564ProfileEntry 7 }
+
+tnY1564UserFrameSize OBJECT-TYPE
+ SYNTAX INTEGER(64..10236)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "
+ User defined frame size of the background traffic.
+ Valid range is 64 to 10236 bytes.
+ "
+ ::= { tnY1564ProfileEntry 8 }
+
+tnY1564DwellTime OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "
+ When a trial (a single step of a subtest) is executed, background
+ traffic is transmitted for a certain period of time. When that
+ period has elapsed, the Dwell Time determines how long to wait
+ before reading hardware counters and status in order to assess
+ the status of the trial. The required dwell time must be at least
+ the worst-case roundtrip time, and therefore a.o. depends on the
+ physical distance between the near and far ends.
+
+ Valid range is from 100 to 10000 in steps of 100 milliseconds
+ with a default of 500 milliseconds.
+ "
+ ::= { tnY1564ProfileEntry 9 }
+
+tnY1564SacFLR OBJECT-TYPE
+ SYNTAX INTEGER(0..1000)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "
+ Defines the acceptable Frame Loss Ratio.
+ The Acceptable FLR is measured in permille. Setting this to
+ 1000 effectively disables this check.The number is used in all
+ enabled subtests. Only delay measurement PDUs and green
+ background traffic undergoes FLR check. If the number of looped
+ green frames differs from the number of transmitted green frames
+ by more than the 'Acceptable FLR', the test is considered failing,
+ otherwise passing.If the EVC contains multiple ECEs that matches
+ on the same VLAN ID (UNI ingress) and the EVC uses 'Tx Lookup' equal
+ to 'VID-PCP', the NNI ingress rules count looped traffic per NNI
+ outer tag's PCP, and therefore provide more detailed information about
+ which ECE is failing, than if the EVC uses 'Tx Lookup' equal to 'VID',
+ where all looped traffic arriving on NNI is counted on the same ECE.
+ The disadvantage of the 'VID-PCP' method is that it uses more chip
+ resources than does the 'VID' method.
+
+ Valid range is from 0 to 1000 with a default of 0‰.
+ "
+ ::= { tnY1564ProfileEntry 10 }
+
+tnY1564SacFTD OBJECT-TYPE
+ SYNTAX INTEGER(0..10000)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "
+ Defines the acceptable Frame Transfer Delay, measured in
+ milliseconds. If the highest observed frame transfer delay
+ exceeds this, the test fails.
+
+ Valid range is from 0 to 10000 with a default of 0 milliseconds.
+ A value of 0 disables this check.
+ "
+ ::= { tnY1564ProfileEntry 11 }
+
+tnY1564SacFDV OBJECT-TYPE
+ SYNTAX INTEGER(0..10000)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "
+ Defines the acceptable Frame Delay Variation, measured in milliseconds.
+ If the highest observed frame delay variation exceeds this, the test fails.
+ Valid range is from 0 to 10000 with a default of 0 milliseconds.
+ A value of 0 disables this check.
+ "
+ ::= { tnY1564ProfileEntry 12 }
+
+tnY1564CirEnable OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "
+ Set, to enable the CIR test."
+ ::= { tnY1564ProfileEntry 13 }
+
+tnY1564CirStepDuration OBJECT-TYPE
+ SYNTAX INTEGER(1..3600)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "
+ Each step in the CIR configuration test applies background
+ traffic for this number of seconds.
+ Valid range is from 1 to 3600 with a default of 10 seconds.
+ "
+ ::= { tnY1564ProfileEntry 14 }
+
+tnY1564CirDmInterval OBJECT-TYPE
+ SYNTAX INTEGER(100..10000)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "
+ A Y.1731 1DM or DMM frame (depending on type of test) is
+ transmitted every so many milliseconds, in order to perform
+ delay measurements (DM). The number should be selected so
+ that at least three DM frames are transmitted during a trial
+ in order to obtain delay variation results. After each trial
+ the measured FTD and FDV is compared against the SAC's Acceptable FLR, FTD, and FDV.
+
+ Valid range is from 100 to 10000 in steps of 100 milliseconds
+ with a default of 500 milliseconds.
+ A value of 0 effectively disables transmission of DM frames,
+ which thereby indirectly disables the check against the SAC.
+ "
+ ::= { tnY1564ProfileEntry 15 }
+
+tnY1564CirStepCount OBJECT-TYPE
+ SYNTAX INTEGER(1..1000)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "
+ The number of steps (trials) used to reach CIR. If, for example,
+ Step Count is set to 4, four trials are executed. The first runs
+ at 25% of this ECEs share of CIR, the second at 50%, then 75%,
+ and finally 100%. A step count of 1 corresponds to executing
+ Y.1564's A.1 test (Simple CIR Validation Test). A step count
+ greater than 1 corresponds to executing Y.1564's A.2 test (Step Load CIR Test).
+
+ Valid range is from 1 to 1000 with a default of 4 steps.
+ "
+ ::= { tnY1564ProfileEntry 16 }
+
+tnY1564EirEnable OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "
+ Set, to enable the EIR test."
+ ::= { tnY1564ProfileEntry 17 }
+
+tnY1564EirDuration OBJECT-TYPE
+ SYNTAX INTEGER(1..3600)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "
+ The EIR configuration test is executed in one single trial,
+ whose duration is configured with this parameter.
+ Valid range is from 1 to 3600 with a default of 10 seconds.
+ "
+ ::= { tnY1564ProfileEntry 18 }
+
+tnY1564EirDmInterval OBJECT-TYPE
+ SYNTAX INTEGER(100..10000)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "
+ A Y.1731 1DM or DMM frame (depending on type of test) is
+ transmitted every so many milliseconds, in order to perform
+ delay measurements (DM). The number should be selected so
+ that at least three DM frames are transmitted during a trial
+ in order to obtain delay variation results. After each trial
+ the measured FTD and FDV is compared against the SAC's Acceptable FLR, FTD, and FDV.
+
+ Valid range is from 100 to 10000 in steps of 100 milliseconds
+ with a default of 500 milliseconds.
+ A value of 0 effectively disables transmission of DM frames,
+ which thereby indirectly disables the check against the SAC.
+ "
+ ::= { tnY1564ProfileEntry 19 }
+
+tnY1564TrafficPolicingEnable OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "
+ Set, to enable the Traffic Policing test."
+ ::= { tnY1564ProfileEntry 20 }
+
+tnY1564TrafficPolicingDuration OBJECT-TYPE
+ SYNTAX INTEGER(1..3600)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "
+ The Traffic Policing test is executed in one single trial,
+ whose duration is configured with this parameter.
+ Valid range is from 1 to 3600 with a default of 10 seconds.
+ "
+ ::= { tnY1564ProfileEntry 21 }
+
+tnY1564TrafficPolicingDmInterval OBJECT-TYPE
+ SYNTAX INTEGER(100..10000)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "
+ A Y.1731 1DM or DMM frame (depending on type of test) is
+ transmitted every so many milliseconds, in order to perform
+ delay measurements (DM). The number should be selected so
+ that at least three DM frames are transmitted during a trial
+ in order to obtain delay variation results. After each trial
+ the measured FTD and FDV is compared against the SAC's Acceptable FLR, FTD, and FDV.
+
+ Valid range is from 100 to 10000 in steps of 100 milliseconds
+ with a default of 500 milliseconds.
+ A value of 0 effectively disables transmission of DM frames,
+ which thereby indirectly disables the check against the SAC.
+ "
+ ::= { tnY1564ProfileEntry 22 }
+
+tnY1564PerfTestEnable OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "
+ Set, to enable the Performance test."
+ ::= { tnY1564ProfileEntry 23 }
+
+tnY1564PerfTestDuration OBJECT-TYPE
+ SYNTAX INTEGER {
+ mins15(1),
+ hours2(2),
+ hours24(3),
+ userDefined(4)
+ }
+
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "
+ The performance test is executed in one single trial, whose
+ duration is configured with this parameter. There are
+ Y.1564-specified standard durations and a custom duration can be
+ specified by selecting User-defined Duration option.
+ "
+ ::= { tnY1564ProfileEntry 24 }
+
+tnY1564PerfTestUserDuration OBJECT-TYPE
+ SYNTAX INTEGER(1..86400)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "
+ User defined duration. Valid range is from 1 to 86400 with a default of 900 seconds
+ "
+ ::= { tnY1564ProfileEntry 25 }
+
+tnY1564PerfTestDmInterval OBJECT-TYPE
+ SYNTAX INTEGER(100..10000)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "
+ A Y.1731 1DM or DMM frame (depending on type of test) is
+ transmitted every so many milliseconds, in order to perform
+ delay measurements (DM). The number should be selected so
+ that at least three DM frames are transmitted during a trial
+ in order to obtain delay variation results. After each trial
+ the measured FTD and FDV is compared against the SAC's Acceptable FLR, FTD, and FDV.
+
+ Valid range is from 100 to 10000 in steps of 100 milliseconds
+ with a default of 500 milliseconds.
+ A value of 0 effectively disables transmission of DM frames,
+ which thereby indirectly disables the check against the SAC.
+ "
+ ::= { tnY1564ProfileEntry 26 }
+
+tnY1564ProfileStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The status of the row.
+ The writable columns in a row can not be changed if the row
+ is active. All columns must have a valid value before a row
+ can be activated.
+ "
+ ::= { tnY1564ProfileEntry 27 }
+
+
+
+-- ------------------------------------------------------
+-- ------------------------------------------------------
+-- ------------------------------------------------------
+-- ------------------------------------------------------
+
+tnY1564ReportTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TnY1564ReportEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table provides configuration of SOAM Maintenance Point.
+ "
+ ::= { tnY1564ReportMgmt 1 }
+
+tnY1564ReportEntry OBJECT-TYPE
+ SYNTAX TnY1564ReportEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A entry in the table represents a configuration for local SOAM."
+ INDEX { IMPLIED tnY1564ReportName }
+ ::= { tnY1564ReportTable 1 }
+
+TnY1564ReportEntry ::=
+ SEQUENCE{
+ tnY1564ReportName SnmpAdminString,
+ tnY1564ReportDscr DisplayString,
+ tnY1564ReportTime DisplayString,
+ tnY1564ReportTftpAddrType InetAddressType,
+ tnY1564ReportTftpAddr InetAddress,
+ tnY1564ReportTestStatus INTEGER,
+ tnY1564ReportAction INTEGER
+ }
+
+tnY1564ReportName OBJECT-TYPE
+ SYNTAX SnmpAdminString
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The name, ASCII range 33-126, of this table."
+ ::= { tnY1564ReportEntry 1 }
+
+tnY1564ReportDscr OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..127))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The description of this table."
+ ::= { tnY1564ReportEntry 2 }
+
+tnY1564ReportTime OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (26))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The description of this table."
+ ::= { tnY1564ReportEntry 3 }
+
+tnY1564ReportTftpAddrType OBJECT-TYPE
+ SYNTAX InetAddressType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The tftp server IP address type. "
+ ::= { tnY1564ReportEntry 4 }
+
+tnY1564ReportTftpAddr OBJECT-TYPE
+ SYNTAX InetAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The tftp server IP address. "
+ ::= { tnY1564ReportEntry 5 }
+
+tnY1564ReportTestStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ inactive(1),
+ executing(2),
+ cancelling(3),
+ cancelled(4),
+ passed(5),
+ failed(6)
+ }
+
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "
+ "
+ ::= { tnY1564ReportEntry 6 }
+
+tnY1564ReportAction OBJECT-TYPE
+ SYNTAX INTEGER {
+ noAction(1),
+ cancelTest(2),
+ saveReport(3),
+ deleteReport(4)
+ }
+
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "
+ "
+ ::= { tnY1564ReportEntry 7 }
+END