summaryrefslogtreecommitdiff
path: root/MIBS/transition/TN-PTP-MIB
diff options
context:
space:
mode:
authorDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
committerDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
commit98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch)
tree9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/transition/TN-PTP-MIB
downloadmibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.tar.gz
mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.zip
Initial commitHEADmain
Diffstat (limited to 'MIBS/transition/TN-PTP-MIB')
-rw-r--r--MIBS/transition/TN-PTP-MIB973
1 files changed, 973 insertions, 0 deletions
diff --git a/MIBS/transition/TN-PTP-MIB b/MIBS/transition/TN-PTP-MIB
new file mode 100644
index 0000000..c204425
--- /dev/null
+++ b/MIBS/transition/TN-PTP-MIB
@@ -0,0 +1,973 @@
+-- ***********************************************************************************************
+-- TN-PTP-MIB.smi: Transition Networks Enterprise MIB for TN device SyncE feature
+--
+-- Copyright (c) 2013 by Transition Networks, Inc.
+-- All rights reserved.
+--
+-- ***********************************************************************************************
+--
+
+TN-PTP-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ TruthValue, RowStatus
+ FROM SNMPv2-TC
+ MODULE-IDENTITY,
+ OBJECT-IDENTITY,
+ InetAddressType, InetAddress
+ FROM INET-ADDRESS-MIB
+ entPhysicalIndex FROM ENTITY-MIB
+ tnProducts FROM TRANSITION-SMI;
+
+tnPtpMIB MODULE-IDENTITY
+ LAST-UPDATED "201311110000Z"
+ ORGANIZATION "Transition Networks, Inc."
+ CONTACT-INFO
+ " Transition Networks
+ Technical Support
+ 10900 Red Circle Drive
+ Minnetonka, MN 55343 USA
+ Tel: +1-800-526-9267
+
+ E-mail: techsupport@transition.com"
+
+ DESCRIPTION
+ "The mib provides functionalities for managing PTP."
+
+ REVISION "201311110000Z"
+ DESCRIPTION
+ "Initial Revision of this module"
+ ::= { tnProducts 123 }
+
+tnPtp OBJECT IDENTIFIER ::= { tnPtpMIB 1 }
+--
+-- PTP Clock Modes
+--
+tnPtpClkModesTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TnPtpClkModesEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Table of SyncE External I/O"
+ ::= { tnPtp 1 }
+
+tnPtpClkModesEntry OBJECT-TYPE
+ SYNTAX TnPtpClkModesEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "An entry in the table,tnPtpClkModesTable"
+ INDEX { entPhysicalIndex }
+ ::= { tnPtpClkModesTable 1 }
+
+TnPtpClkModesEntry ::= SEQUENCE
+{
+ tnPtpInState INTEGER,
+ tnPtpOutState INTEGER,
+ tnPtpInFreq INTEGER,
+ tnPtpOutFreq INTEGER,
+ tnPtpImpedance INTEGER,
+ tnPtpActualInFreq INTEGER,
+ tnPtpActualOutFreq INTEGER
+}
+
+tnPtpInState OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ enable(1),
+ disable(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "IEEE 1588 Input State."
+ ::= { tnPtpClkModesEntry 1 }
+
+tnPtpOutState OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ enable(1),
+ disable(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "IEEE 1588 Output State."
+ ::= { tnPtpClkModesEntry 2 }
+
+tnPtpInFreq OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ onePps(0),
+ f8kHz(1),
+ f64kHz(2),
+ f1544kHz(3),
+ f2048kHz(4),
+ f10000kHz(5),
+ f19440kHz(6),
+ f25Mhz(7)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Clock frequency 1 PPS or
+ 8k-25Mhz table of values."
+ ::= { tnPtpClkModesEntry 3 }
+
+tnPtpOutFreq OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The following values are possible:
+ Editable value with the possible range of values are 1 - 25000000 (1 - 25MHz)."
+ ::= { tnPtpClkModesEntry 4 }
+
+tnPtpImpedance OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ imp50(1),
+ imp75(2),
+ hi-Z(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Select the impedance termination of the input clock.
+ The following values are possible:
+ 1. 50 : 50 ohm impedance.
+ 2. 75 : 75 ohm impedance.
+ 3. Hi-Z : no impedance termination driven, tri-stated or floating."
+ ::= { tnPtpClkModesEntry 5 }
+
+tnPtpActualInFreq OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The actual input frequency in Hz."
+ ::= { tnPtpClkModesEntry 6 }
+
+tnPtpActualOutFreq OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The actual output frequency in Hz. If output state is disabled set to 0"
+ ::= { tnPtpClkModesEntry 7 }
+
+--
+-- PTP Add New Clk Configuration
+--
+tnPtpCreateClkConfTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TnPtpCreateClkConfEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Table of PTP ClkInstance"
+ ::= { tnPtp 2 }
+
+tnPtpCreateClkConfEntry OBJECT-TYPE
+ SYNTAX TnPtpCreateClkConfEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "An entry in the table,tnPtpCreateClkConfTable"
+ INDEX { tnPtpCreateClkConfIndex }
+ ::= { tnPtpCreateClkConfTable 1 }
+
+
+TnPtpCreateClkConfEntry ::= SEQUENCE
+{
+ tnPtpCreateClkConfIndex INTEGER,
+ tnPtpDeviceType INTEGER,
+ tnPtpTwoStepFlag TruthValue,
+ tnPtpClockId OCTET STRING,
+ tnPtpOneWay TruthValue,
+ tnPtpProtocol INTEGER,
+ tnPtpVLANTag TruthValue,
+ tnPtpVID INTEGER,
+ tnPtpPCP INTEGER,
+ tnPtpClkConfRowStatus RowStatus
+}
+
+tnPtpCreateClkConfIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Index of ptp clocks."
+ ::= { tnPtpCreateClkConfEntry 1 }
+
+tnPtpDeviceType OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ inactive(0),
+ ordBound(1),
+ p2pTransp(2),
+ e2eTransp(3),
+ masterOnly(4),
+ slaveOnly(5)
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION "Indicates the Type of the Clock Instance. There are five Device Types.
+ 1. Ord-Bound - clock's Device Type is Ordinary-Boundary Clock.
+ 2. P2p Transp - clock's Device Type is Peer to Peer Transparent Clock.
+ 3. E2e Transp - clock's Device Type is End to End Transparent Clock.
+ 4. Master Only - clock's Device Type is Master Only.
+ 5. Slave Only - clock's Device Type is Slave Only."
+ ::= { tnPtpCreateClkConfEntry 2 }
+
+tnPtpTwoStepFlag OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION "Static member: defined by the system, true if two-step Sync events and Pdelay_Resp events are used."
+ ::= { tnPtpCreateClkConfEntry 3 }
+
+tnPtpClockId OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(0..256))
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "A unique clock identifier."
+ ::= { tnPtpCreateClkConfEntry 4 }
+
+tnPtpOneWay OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION "If true, one-way measurements are used. This parameter applies only to a slave. In one-way mode no delay
+ measurements are performed, i.e. this is applicable only if frequency synchronization is needed. The master always responds to delay requests.."
+ ::= { tnPtpCreateClkConfEntry 5 }
+
+tnPtpProtocol OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ ethernet(0),
+ ipv4multi(1),
+ ipv4uni(2)
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION "Transport protocol used by the PTP protocol engine
+ ethernet PTP over Ethernet multicast
+ ip4multi PTP over IPv4 multicast
+ ip4uni PTP over IPv4 unicast
+ Note : IPv4 unicast protocol only works in Master only and Slave only clocks
+ See parameter Device Type
+ In a unicast Slave only clock you also need configure which master clocks
+ to request Announce and Sync messages from. See: Unicast Slave Configuration."
+ ::= { tnPtpCreateClkConfEntry 6 }
+
+tnPtpVLANTag OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION "Enables the VLAN tagging for the PTP frames.
+ Note: Packets are only tagged if the port is configured for vlan tagging. i.e:
+ Port Type != Unaware and PortVLAN mode == None, and the port is member of the VLAN."
+ ::= { tnPtpCreateClkConfEntry 7 }
+
+tnPtpVID OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION "VLAN Identifier used for tagging the PTP frames."
+ ::= { tnPtpCreateClkConfEntry 8 }
+
+tnPtpPCP OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION "Priority Code Point value used for PTP frames."
+ ::= { tnPtpCreateClkConfEntry 9 }
+
+tnPtpClkConfRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The status of the row.
+
+ The writable columns in a row cannot be changed if the row
+ is active. All columns must have a valid value before a row
+ can be activated."
+ ::= { tnPtpCreateClkConfEntry 10 }
+
+--
+-- PTP Clk Configuration 0
+--
+tnPtpClkConf0Table OBJECT-TYPE
+ SYNTAX SEQUENCE OF TnPtpClkConf0Entry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Table of PTP ClkInstance"
+ ::= { tnPtp 3 }
+
+tnPtpClkConf0Entry OBJECT-TYPE
+ SYNTAX TnPtpClkConf0Entry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "An entry in the table,tnPtpClkConf0Table"
+ INDEX { tnPtpClkConf0Index }
+ ::= { tnPtpClkConf0Table 1 }
+
+
+TnPtpClkConf0Entry ::= SEQUENCE
+{
+ tnPtpClkConf0Index INTEGER,
+
+ tnPtpDefaultDom INTEGER,
+ tnPtpDefaultClockQuality OCTET STRING,
+ tnPtpDefaultPri1 INTEGER,
+ tnPtpDefaultPri2 INTEGER,
+
+ tnPtpTime OCTET STRING,
+ tnPtpAdjustMethod INTEGER,
+ tnPtpSynce INTEGER,
+}
+
+tnPtpClkConf0Index OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Indicates the Instance of a particular Clock Instance [0..CLOCK_INST_MAX]."
+ ::= { tnPtpClkConf0Entry 1 }
+
+tnPtpDefaultDom OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Clock domain [0..127]."
+ ::= { tnPtpClkConf0Entry 2 }
+
+tnPtpDefaultClockQuality OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(0..256))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The clock quality is determined by the system, and holds 3 parts: Clock Class, Clock Accuracy and OffsetScaledLog Variance as defined in IEEE1588.
+ The Clock Accuracy values are defined in IEEE1588 table 6 (Currently the clock Accuracy is set to 'Unknown' as default)."
+ ::= { tnPtpClkConf0Entry 3 }
+
+tnPtpDefaultPri1 OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Clock priority 1 [0..255] used by the BMC master select algorithm."
+ ::= { tnPtpClkConf0Entry 4 }
+
+tnPtpDefaultPri2 OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Clock priority 2 [0..255] used by the BMC master select algorithm."
+ ::= { tnPtpClkConf0Entry 5 }
+
+tnPtpTime OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(0..256))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Shows the actual PTP time with nanosecond resolution."
+ ::= { tnPtpClkConf0Entry 6 }
+
+tnPtpAdjustMethod OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ internal(1),
+ vcxo(2),
+ software(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Shows the actual clock adjustment method. The method depends on the available hardware."
+ ::= { tnPtpClkConf0Entry 7 }
+
+tnPtpSynce OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ doNothing(1),
+ sync(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Activate to synchronize the System Clock to PTP Time."
+ ::= { tnPtpClkConf0Entry 8 }
+
+--
+-- PTP Clk Configuration 1
+--
+tnPtpClkConfTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TnPtpClkConfEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Table of PTP ClkInstance"
+ ::= { tnPtp 4 }
+
+tnPtpClkConfEntry OBJECT-TYPE
+ SYNTAX TnPtpClkConfEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "An entry in the table,tnPtpClkConfTable"
+ INDEX { tnPtpClkConfIndex }
+ ::= { tnPtpClkConfTable 1 }
+
+
+TnPtpClkConfEntry ::= SEQUENCE
+{
+ tnPtpClkConfIndex INTEGER,
+
+ tnPtpStpRm INTEGER,
+ tnPtpOffset OCTET STRING,
+ tnPtpPathDelay OCTET STRING,
+ tnPtpDelayFilter INTEGER,
+ tnPtpFilterPeriod INTEGER,
+ tnPtpFilterDist INTEGER,
+
+ tnPtpParentPortId OCTET STRING,
+ tnPtpParentPort INTEGER,
+ tnPtpParentPStat TruthValue,
+ tnPtpParentVar INTEGER,
+ tnPtpParentChgRate INTEGER,
+ tnPtpParentGMId OCTET STRING,
+ tnPtpParentGMQual OCTET STRING,
+ tnPtpParentPri1 INTEGER,
+ tnPtpParentPri2 INTEGER
+}
+
+tnPtpClkConfIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Indicates the Instance of a particular Clock Instance [0..CLOCK_INST_MAX]."
+ ::= { tnPtpClkConfEntry 1 }
+
+tnPtpStpRm OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Steps Removed : It is the number of PTP clocks traversed from the grandmaster to the local slave clock."
+ ::= { tnPtpClkConfEntry 2 }
+
+tnPtpOffset OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(0..256))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Time difference between the master clock and the local slave clock, measured in ns."
+ ::= { tnPtpClkConfEntry 3 }
+
+tnPtpPathDelay OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(0..256))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The mean propagation time for the link between the master and the local slave."
+ ::= { tnPtpClkConfEntry 4 }
+
+tnPtpDelayFilter OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The default delay filter is a low pass filter, with a time constant of 2**DelayFilter*DelayRequestRate.
+ The value must be in the range of 1..6."
+ ::= { tnPtpClkConfEntry 5 }
+
+tnPtpFilterPeriod OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The default offset filter uses a minimum delay filter method
+ i.e. The minimum measured offset during Period samples is used in the calculation.
+ The value must be in the range of 1..1000."
+ ::= { tnPtpClkConfEntry 6 }
+
+tnPtpFilterDist OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The distance between two calculations is Dist periods.
+ Note: In configurations with Timestamp enabled PHYs, the period is automatically increased, if (period*dist < SyncPackets pr sec/4),
+ i.e. max 4 adjustments are made pr sec.
+ If Dist is 1 the offset is averaged over the Period,
+ If Dist is >1 the offset is calculated using 'min' offset.
+ The value must be in the range of 1..10"
+ ::= { tnPtpClkConfEntry 7 }
+
+tnPtpParentPortId OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(0..256))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Clock identity for the parent clock, if the local clock is not a slave, the value is the clocks own id."
+ ::= { tnPtpClkConfEntry 8 }
+
+tnPtpParentPort OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Port Id for the parent master port."
+ ::= { tnPtpClkConfEntry 9 }
+
+tnPtpParentPStat OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Parents Stats (always false)."
+ ::= { tnPtpClkConfEntry 10 }
+
+tnPtpParentVar OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "It is observed parent offset scaled log variance."
+ ::= { tnPtpClkConfEntry 11 }
+
+tnPtpParentChgRate OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Observed Parent Clock Phase Change Rate. i.e. the slave clocks rate offset compared to the master. (unit = ns per s)."
+ ::= { tnPtpClkConfEntry 12 }
+
+tnPtpParentGMId OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(0..256))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Clock identity for the grand master clock, if the local clock is not a slave, the value is the clocks own id."
+ ::= { tnPtpClkConfEntry 13 }
+
+tnPtpParentGMQual OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(0..256))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The clock quality announced by the grand master."
+ ::= { tnPtpClkConfEntry 14 }
+
+tnPtpParentPri1 OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Clock priority 1 announced by the grand master."
+ ::= { tnPtpClkConfEntry 15 }
+
+tnPtpParentPri2 OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Clock priority 2 announced by the grand master."
+ ::= { tnPtpClkConfEntry 16 }
+
+--
+-- PTP Clk Configuration 2
+--
+tnPtpClkConf2Table OBJECT-TYPE
+ SYNTAX SEQUENCE OF TnPtpClkConf2Entry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Table 2 of PTP ClkInstance"
+ ::= { tnPtp 5 }
+
+tnPtpClkConf2Entry OBJECT-TYPE
+ SYNTAX TnPtpClkConf2Entry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "An entry in the table,tnPtpClkConf2Table"
+ INDEX { tnPtpClkConfIndex2 }
+ ::= { tnPtpClkConf2Table 1 }
+
+
+TnPtpClkConf2Entry ::= SEQUENCE
+{
+ tnPtpClkConfIndex2 INTEGER,
+
+ tnPtpUtcOffset INTEGER,
+ tnPtpValid TruthValue,
+ tnPtpLeap59 TruthValue,
+ tnPtpLeap61 TruthValue,
+ tnPtpTimeTrac TruthValue,
+ tnPtpFreqTrac TruthValue,
+ tnPtpTimeScale TruthValue,
+ tnPtpTimeSource INTEGER,
+
+ tnPtpDisplay TruthValue,
+ tnPtpPEnable TruthValue,
+ tnPtpIEnable TruthValue,
+ tnPtpDEnable TruthValue,
+ tnPtpPConstant INTEGER,
+ tnPtpIConstant INTEGER,
+ tnPtpDConstant INTEGER,
+ tnPtpServoDelayFilter INTEGER
+}
+
+tnPtpClkConfIndex2 OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Indicates the Instance of a particular Clock Instance [0..CLOCK_INST_MAX]."
+ ::= { tnPtpClkConf2Entry 1 }
+
+tnPtpUtcOffset OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Unicast Offset must be an integer value between 0 and 10000."
+ ::= { tnPtpClkConf2Entry 2 }
+
+tnPtpValid OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Valid."
+ ::= { tnPtpClkConf2Entry 3 }
+
+tnPtpLeap59 OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Leap 59."
+ ::= { tnPtpClkConf2Entry 4 }
+
+tnPtpLeap61 OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Leap 61."
+ ::= { tnPtpClkConf2Entry 5 }
+
+tnPtpTimeTrac OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Time Trac."
+ ::= { tnPtpClkConf2Entry 6 }
+
+tnPtpFreqTrac OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Freq Trac."
+ ::= { tnPtpClkConf2Entry 7 }
+
+tnPtpTimeScale OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Time Scale."
+ ::= { tnPtpClkConf2Entry 8 }
+
+tnPtpTimeSource OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Time Source. Value of 0-255"
+ ::= { tnPtpClkConf2Entry 9 }
+
+tnPtpDisplay OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "If true then Offset From Master, MeanPathDelay and clockAdjustment are logged on the debug terminal."
+ ::= { tnPtpClkConf2Entry 10 }
+
+tnPtpPEnable OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "If true the P part of the algorithm is included."
+ ::= { tnPtpClkConf2Entry 11 }
+
+tnPtpIEnable OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "If true the I part of the algorithm is included."
+ ::= { tnPtpClkConf2Entry 12 }
+
+tnPtpDEnable OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "If true the D part of the algorithm is included."
+ ::= { tnPtpClkConf2Entry 13 }
+
+tnPtpPConstant OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The default clock servo uses a PID regulator to calculate the current clock rate. i.e.
+ clockAdjustment = OffsetFromMaster/ P constant + Integral(OffsetFromMaster)/ I constant +
+ Differential OffsetFromMaster)/ D constant [1..1000]."
+ ::= { tnPtpClkConf2Entry 14 }
+
+tnPtpIConstant OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The default clock servo uses a PID regulator to calculate the current clock rate. i.e.
+ clockAdjustment = OffsetFromMaster/ P constant + Integral(OffsetFromMaster)/ I constant +
+ Differential OffsetFromMaster)/ D constant [1..10000]."
+ ::= { tnPtpClkConf2Entry 15 }
+
+tnPtpDConstant OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The default clock servo uses a PID regulator to calculate the current clock rate. i.e.
+ clockAdjustment = OffsetFromMaster/ P constant + Integral(OffsetFromMaster)/ I constant +
+ Differential OffsetFromMaster)/ D constant [1..10000]."
+ ::= { tnPtpClkConf2Entry 16 }
+
+tnPtpServoDelayFilter OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The default delay filter is a low pass filter, with a time constant of 2**DelayFilter*DelayRequestRate.
+ This is for the custom filter."
+ ::= { tnPtpClkConf2Entry 17 }
+
+--
+-- PTP Unicast Slave Config
+--
+tnPtpUnicastSlaveTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TnPtpUnicastSlaveEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Table of PTP Unicast Slave"
+ ::= { tnPtp 6 }
+
+tnPtpUnicastSlaveEntry OBJECT-TYPE
+ SYNTAX TnPtpUnicastSlaveEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "An entry in the table,tnPtpUnicastSlaveTable"
+ INDEX { tnPtpUnicastInstIndex, tnPtpUnicastSlaveIndex }
+ ::= { tnPtpUnicastSlaveTable 1 }
+
+
+TnPtpUnicastSlaveEntry ::= SEQUENCE
+{
+ tnPtpUnicastInstIndex INTEGER,
+ tnPtpUnicastSlaveIndex INTEGER,
+ tnPtpUnicastDuration INTEGER,
+ tnPtpIPAddress InetAddress,
+ tnPtpGrant INTEGER,
+ tnPtpCommState INTEGER
+}
+
+tnPtpUnicastInstIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Indicates the Instance of a particular Clock Instance [0..3]."
+ ::= { tnPtpUnicastSlaveEntry 1 }
+
+tnPtpUnicastSlaveIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Indicates the Instance of a particular Unicast Slave [0..4]."
+ ::= { tnPtpUnicastSlaveEntry 2 }
+
+tnPtpUnicastDuration OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The number of seconds a master is requested to send Announce/Sync messages.
+ The request is repeated from the slave each Duration/4 seconds. [10..1000]."
+ ::= { tnPtpUnicastSlaveEntry 3 }
+
+tnPtpIPAddress OBJECT-TYPE
+ SYNTAX InetAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "IPv4 Address of the Master clock."
+ ::= { tnPtpUnicastSlaveEntry 4 }
+
+tnPtpGrant OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The granted repetition period for the sync message."
+ ::= { tnPtpUnicastSlaveEntry 5 }
+
+tnPtpCommState OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ idle(1),
+ init(2),
+ conn(3),
+ sell(4),
+ sync(5)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION " The state of the communication with the master, possible values are:
+ IDLE : The entry is not in use.
+ INIT : Announce is sent to the master (Waiting for a response).
+ CONN : The master has responded.
+ SELL : The assigned master is selected as current master.
+ SYNC : The master is sending Sync messages."
+ ::= { tnPtpUnicastSlaveEntry 6 }
+
+--
+-- PTP Clock Port Data Set Configuration
+--
+tnPtpPortConfTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TnPtpPortConfEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Table of PTP Clock Port Data Set Configuration"
+ ::= { tnPtp 7 }
+
+tnPtpPortConfEntry OBJECT-TYPE
+ SYNTAX TnPtpPortConfEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "An entry in the table,tnPtpPortConfTable"
+ INDEX { tnPtpPortConfInstIndex, tnPtpPortConfIndex }
+ ::= { tnPtpPortConfTable 1 }
+
+
+TnPtpPortConfEntry ::= SEQUENCE
+{
+ tnPtpPortConfInstIndex INTEGER,
+ tnPtpPortConfIndex INTEGER,
+ tnPtpStat OCTET STRING,
+ tnPtpMDR INTEGER,
+ tnPtpMeanPath OCTET STRING,
+ tnPtpAnv INTEGER,
+ tnPtpATO INTEGER,
+ tnPtpSyv INTEGER,
+ tnPtpSyncIntErr TruthValue,
+ tnPtpDim INTEGER,
+ tnPtpMPR INTEGER,
+ tnPtpDelayAsym INTEGER,
+ tnPtpIngerssLat INTEGER,
+ tnPtpEgressLat INTEGER,
+ tnPtpVersion INTEGER,
+ tnPtpPortConfRowStatus RowStatus
+}
+
+tnPtpPortConfInstIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Indicates the Instance of a particular Clock Instance [0..3]."
+ ::= { tnPtpPortConfEntry 1 }
+
+tnPtpPortConfIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Static member port Identity : Port number [1..max port no]."
+ ::= { tnPtpPortConfEntry 2 }
+
+tnPtpStat OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Dynamic member portState: Current state of the port."
+ ::= { tnPtpPortConfEntry 3 }
+
+tnPtpMDR OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Dynamic member log Min Delay Req Interval: The delay request interval announced by the master."
+ ::= { tnPtpPortConfEntry 4 }
+
+tnPtpMeanPath OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "The path delay measured by the port in P2P mode. In E2E mode this value is 0."
+ ::= { tnPtpPortConfEntry 5 }
+
+tnPtpAnv OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION "The interval for issuing announce messages in master state. [-3..4]"
+ ::= { tnPtpPortConfEntry 6 }
+
+tnPtpATO OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION "The timeout for receiving announce messages on the port. [-1..10]"
+ ::= { tnPtpPortConfEntry 7 }
+
+tnPtpSyv OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION "The interval for issuing sync messages in master. [-7..4]"
+ ::= { tnPtpPortConfEntry 8 }
+
+tnPtpSyncIntErr OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Synce Interval Error truth value"
+ ::= { tnPtpPortConfEntry 9 }
+
+tnPtpDim OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ e2e(1),
+ p2p(2)
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION "Configurable member delayMechanism: The delay mechanism used for the port:
+ e2e End to end delay measurement
+ p2p Peer to peer delay measurement.
+ Can be defined per port in an Ordinary/Boundary clock.
+ In a transparent clock all ports use the same delay mechanism, determined by the clock type."
+ ::= { tnPtpPortConfEntry 10 }
+
+tnPtpMPR OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION "The interval for issuing Delay_Req messages for the port in E2e mode.
+ This value is announced from the master to the slave in an announce message. The value is reflected in the MDR field in the Slave
+ The interval for issuing Pdelay_Req messages for the port in P2P mode
+ Note: The interpretation of this parameter has changed from release 2.40.
+ In earlier versions the value was interpreted relative to the Sync interval, this was a violation of the standard, so now the value is interpreted as an interval.
+ I.e. MPR = 0 =>1 Delay_Req pr sec, independent of the Sync rate. [-7..5]"
+ ::= { tnPtpPortConfEntry 11 }
+
+tnPtpDelayAsym OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION "If the transmission delay for a link in not symmetric, the asymmetry can be configured here,
+ see IEEE 1588 Section 7.4.2 Communication path asymmetry. [-100000..100000]"
+ ::= { tnPtpPortConfEntry 12 }
+
+tnPtpIngerssLat OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION "Ingress latency measured in ns, as defined in IEEE 1588 Section 7.3.4.2. [-100000..100000]"
+ ::= { tnPtpPortConfEntry 13 }
+
+tnPtpEgressLat OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION "Egress latency measured in ns, as defined in IEEE 1588 Section 7.3.4.2. [-100000..100000]"
+ ::= { tnPtpPortConfEntry 14 }
+
+tnPtpVersion OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "The current implementation only supports PTP version 2."
+ ::= { tnPtpPortConfEntry 15 }
+
+tnPtpPortConfRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The status of the row.
+
+ The writable columns in a row cannot be changed if the row
+ is active. All columns must have a valid value before a row
+ can be activated.
+ "
+ ::= { tnPtpPortConfEntry 16 }
+END \ No newline at end of file