diff options
| author | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
|---|---|---|
| committer | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
| commit | 98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch) | |
| tree | 9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/transition/TN-LINK-OAM-MIB | |
| download | mibs-main.tar.gz mibs-main.zip | |
Diffstat (limited to 'MIBS/transition/TN-LINK-OAM-MIB')
| -rw-r--r-- | MIBS/transition/TN-LINK-OAM-MIB | 715 |
1 files changed, 715 insertions, 0 deletions
diff --git a/MIBS/transition/TN-LINK-OAM-MIB b/MIBS/transition/TN-LINK-OAM-MIB new file mode 100644 index 0000000..81c0021 --- /dev/null +++ b/MIBS/transition/TN-LINK-OAM-MIB @@ -0,0 +1,715 @@ +-- ***************************************************************** +-- TN-LINK-OAM-MIB +-- +-- Copyright (c) 2013, Transition Networks Inc. +-- All rights reserved. +-- ***************************************************************** +TN-LINK-OAM-MIB DEFINITIONS ::= BEGIN +IMPORTS + OBJECT-TYPE, Counter32, Unsigned32, + Integer32, Counter64 + FROM SNMPv2-SMI + -- from [RFC2578] + TimeStamp, TruthValue, DisplayString + FROM SNMPv2-TC + -- from [RFC2579] + ifIndex + FROM IF-MIB + -- from [RFC2863] + dot3OamEntry, dot3OamStatsEntry, dot3OamPeerEntry, + dot3OamEventConfigEntry + FROM DOT3-OAM-MIB + tnProducts + FROM TRANSITION-SMI; + + tnLinkOamMIB MODULE-IDENTITY + LAST-UPDATED "201305280000Z" + ORGANIZATION "Transition Networks, Inc." + CONTACT-INFO + "Transition Networks + Technical Support + + 10900 Red Circle Drive + Minnetonka, MN 55343 USA + Tel: +1-800-526-9267 + + E-mail: techsupport@transition.com + " + DESCRIPTION + "The mib module for managing Link OAM." +::= { tnProducts 140 } + +-- +-- Sections of the Ethernet OAM MIB + + tnLinkOamNotifications OBJECT IDENTIFIER ::= { tnLinkOamMIB 0 } + tnLinkOamObjects OBJECT IDENTIFIER ::= { tnLinkOamMIB 1 } + tnLinkOamConformance OBJECT IDENTIFIER ::= { tnLinkOamMIB 2 } + +-- *************************************************************** +-- +-- Link OAM Port Configuration Group +-- + +tnLinkOamPortConfigTable OBJECT-TYPE + SYNTAX SEQUENCE OF TnLinkOamPortConfigEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table allows the user to inspect the current Link + OAM port configurations, and change them as well. + " + ::= { tnLinkOamObjects 1 } + +tnLinkOamPortConfigEntry OBJECT-TYPE + SYNTAX TnLinkOamPortConfigEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry in the table that contains information of + OAM port configurations. + " + AUGMENTS { dot3OamEntry } + ::= { tnLinkOamPortConfigTable 1 } + +TnLinkOamPortConfigEntry ::= + SEQUENCE { + tnLinkOamLoopbackSupport INTEGER, + tnLinkOamLinkMonitorSupport INTEGER, + tnLinkMIBRetrievalSupport INTEGER, + tnLinkOamLoopbackOperation INTEGER + } + +tnLinkOamLoopbackSupport OBJECT-TYPE + SYNTAX INTEGER { + enable(1), + disable(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Controls whether the loopback support is enabled for the + switch port. Link OAM remote loopback can be used for fault + localization and link performance testing. Enabling the + loopback support will allow the DTE to execute the remote + loopback command that helps in the fault detection. + " + ::= { tnLinkOamPortConfigEntry 1 } + +tnLinkOamLinkMonitorSupport OBJECT-TYPE + SYNTAX INTEGER { + enable(1), + disable(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Controls whether the Link Monitor support is enabled for the + switch port. On enabling the Link Monitor support, the DTE + supports event notification that permits the inclusion of + diagnostic information. + " + ::= { tnLinkOamPortConfigEntry 2 } + +tnLinkMIBRetrievalSupport OBJECT-TYPE + SYNTAX INTEGER { + enable(1), + disable(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Controls whether the MIB Retrieval Support is enabled for + the switch port. On enabling the MIB retrieval support, + the DTE supports polling of various Link OAM based MIB + variables' contents. + " + ::= { tnLinkOamPortConfigEntry 3 } + +tnLinkOamLoopbackOperation OBJECT-TYPE + SYNTAX INTEGER { + enable(1), + disable(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "If the Loopback support is enabled, enabling this field + will start a loopback operation for the port. + " + ::= { tnLinkOamPortConfigEntry 4 } + +-- ************************************************************** +-- +-- Ethernet OAM Monitor Groups +-- + +-- ************************************************************** +-- +-- Ethernet OAM Port Statistics Table +-- + +tnLinkOamStatisticsTable OBJECT-TYPE + SYNTAX SEQUENCE OF TnLinkOamStatisticsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains statistics for the OAM function on a + particular Ethernet-like interface. There is an entry in the + table for every entry in the tnLinkOamTable. + + The displayed counters represent the total number of OAM + frames received and transmitted for the selected port. + Discontinuities of these counter can occur at re-initialization + of the management system. + " + ::= { tnLinkOamObjects 2 } + +tnLinkOamStatisticsEntry OBJECT-TYPE + SYNTAX TnLinkOamStatisticsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry in the table containing statistics information on + the Ethernet OAM function for a single Ethernet-like + interface. + " + AUGMENTS { dot3OamStatsEntry } + ::= { tnLinkOamStatisticsTable 1 } + +TnLinkOamStatisticsEntry ::= + SEQUENCE { + tnLinkOamLinkfaultPDUsRx Counter32, + tnLinkOamLinkfaultPDUsTx Counter32, + tnLinkOamDyingGaspRx Counter32, + tnLinkOamDyingGaspTx Counter32, + tnLinkOamCriticalEventPDUsRx Counter32, + tnLinkOamCriticalEventPDUsTx Counter32 + } + +tnLinkOamLinkfaultPDUsRx OBJECT-TYPE + SYNTAX Counter32 + UNITS "frames" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A count of the number of Link fault PDU's received." + ::= { tnLinkOamStatisticsEntry 1 } + +tnLinkOamLinkfaultPDUsTx OBJECT-TYPE + SYNTAX Counter32 + UNITS "frames" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A count of the number of Link fault PDU's transmitted." + ::= { tnLinkOamStatisticsEntry 2 } + +tnLinkOamDyingGaspRx OBJECT-TYPE + SYNTAX Counter32 + UNITS "frames" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A count of the number of Dying Gasp events received." + ::= { tnLinkOamStatisticsEntry 3 } + +tnLinkOamDyingGaspTx OBJECT-TYPE + SYNTAX Counter32 + UNITS "frames" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A count of the number of Dying Gasp events transmitted." + ::= { tnLinkOamStatisticsEntry 4 } + +tnLinkOamCriticalEventPDUsRx OBJECT-TYPE + SYNTAX Counter32 + UNITS "frames" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A count of the number of Critical event PDU's received." + ::= { tnLinkOamStatisticsEntry 5 } + +tnLinkOamCriticalEventPDUsTx OBJECT-TYPE + SYNTAX Counter32 + UNITS "frames" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A count of the number of Critical event PDU's transmitted." + ::= { tnLinkOamStatisticsEntry 6 } + +-- ************************************************************** +-- +-- Ethernet OAM Port Configuration Status Group +-- + +-- Ethernet OAM Local Port Configuration Status Table +-- Included PDU Permission +tnLinkOamLocalPortConfigStatusTable OBJECT-TYPE + SYNTAX SEQUENCE OF TnLinkOamLocalPortConfigStatusEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table provides Local Link OAM configuration operational + status." + ::= { tnLinkOamObjects 3 } + +tnLinkOamLocalPortConfigStatusEntry OBJECT-TYPE + SYNTAX TnLinkOamLocalPortConfigStatusEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry in the table containing information of Peer Link + OAM configuration operational status." + AUGMENTS { dot3OamEntry } + ::= { tnLinkOamLocalPortConfigStatusTable 1 } + +TnLinkOamLocalPortConfigStatusEntry ::= + SEQUENCE { + tnLinkOamPDUPermission INTEGER, + tnLinkOamLocalMultiplexerState INTEGER, + tnLinkOamLocalParserState INTEGER, + tnLinkOamLocalOrganizationalUniqueIdentifi DisplayString + } + +tnLinkOamPDUPermission OBJECT-TYPE + SYNTAX INTEGER { + linkfault(1), + receiveonly(2), + informationexchangeonly(3), + any(4) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This field is available only for the Local DTE. It + displays the current permission rules set for the + local DTE. Possible values are 'Link fault', 'Receive + only', 'Information exchange only', 'ANY'." + ::= { tnLinkOamLocalPortConfigStatusEntry 1 } + +tnLinkOamLocalMultiplexerState OBJECT-TYPE + SYNTAX INTEGER { + forwarding(1), + discarding(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "When in forwarding state, the Device is forwarding + non-OAMPDUs to the lower sublayer. Incase of + discarding, the device discards all the non-OAMPDU's." + ::= { tnLinkOamLocalPortConfigStatusEntry 2 } + +tnLinkOamLocalParserState OBJECT-TYPE + SYNTAX INTEGER { + forwarding(1), + loopback(2), + discarding(3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "When in forwarding state, Device is forwarding + non-OAMPDUs to higher sublayer. When in loopback, + Device is looping back non-OAMPDUs to the lower + sublayer. When in discarding state, Device is + discarding non-OAMPDUs." + ::= { tnLinkOamLocalPortConfigStatusEntry 3 } + +tnLinkOamLocalOrganizationalUniqueIdentifi OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "24-bit Organizationally Unique Identifier of the + vendor." + ::= { tnLinkOamLocalPortConfigStatusEntry 4 } + +-- Ethernet OAM Peer Port Configuration Status Table + +tnLinkOamPeerPortConfigStatusTable OBJECT-TYPE + SYNTAX SEQUENCE OF TnLinkOamPeerPortConfigStatusEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table provides Peer Link OAM configuration operational + status." + ::= { tnLinkOamObjects 4 } + +tnLinkOamPeerPortConfigStatusEntry OBJECT-TYPE + SYNTAX TnLinkOamPeerPortConfigStatusEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry in the table containing information of Peer Link + OAM configuration operational status." + AUGMENTS { dot3OamPeerEntry } + ::= { tnLinkOamPeerPortConfigStatusTable 1 } + +TnLinkOamPeerPortConfigStatusEntry ::= + SEQUENCE { + tnLinkOamPeerMultiplexerState INTEGER, + tnLinkOamPeerParserState INTEGER, + tnLinkOamPeerOrganizationalUniqueIdentifi DisplayString +} + +tnLinkOamPeerMultiplexerState OBJECT-TYPE + SYNTAX INTEGER { + forwarding(1), + discarding(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "When in forwarding state, the Device is forwarding + non-OAMPDUs to the lower sublayer. Incase of + discarding, the device discards all the non-OAMPDU's." + ::= { tnLinkOamPeerPortConfigStatusEntry 1 } + +tnLinkOamPeerParserState OBJECT-TYPE + SYNTAX INTEGER { + forwarding(1), + loopback(2), + discarding(3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "When in forwarding state, Device is forwarding + non-OAMPDUs to higher sublayer. When in loopback, + Device is looping back non-OAMPDUs to the lower + sublayer. When in discarding state, Device is + discarding non-OAMPDUs." + ::= { tnLinkOamPeerPortConfigStatusEntry 2 } + +tnLinkOamPeerOrganizationalUniqueIdentifi OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "24-bit Organizationally Unique Identifier of the + vendor." + ::= { tnLinkOamPeerPortConfigStatusEntry 3 } + +-- ************************************************************** +-- +-- Ethernet OAM Link Event Status Objects +-- + +--*************************************************************** +-- Frame Error Status Table + +tnLinkOamLinkEventStatusTable OBJECT-TYPE + SYNTAX SEQUENCE OF TnLinkOamLinkEventStatusEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table shows frame error status." + ::= { tnLinkOamObjects 5 } + +tnLinkOamLinkEventStatusEntry OBJECT-TYPE + SYNTAX TnLinkOamLinkEventStatusEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry in the table containing information of + frame error status." + INDEX { ifIndex, tnLinkOamLocationIndex } + ::= { tnLinkOamLinkEventStatusTable 1 } + +TnLinkOamLinkEventStatusEntry ::= + SEQUENCE { + tnLinkOamLocationIndex Unsigned32, + tnLinkOamSequenceNumber Counter32, + tnLinkOamFrameErrorEventTimestamp TimeStamp, + tnLinkOamFrameErrorEventWindow Counter32, + tnLinkOamFrameErrorEventThreshold Counter32, + tnLinkOamFrameErrors Counter32, + tnLinkOamTotalFrameErrors Counter64, + tnLinkOamTotalFrameErrorEvents Counter32, + tnLinkOamFramePeriodErrorEventTimestamp TimeStamp, + tnLinkOamFramePeriodErrorEventWindow Counter32, + tnLinkOamFramePeriodErrorEventThreshold Counter32, + tnLinkOamFramePeriodsErrors Counter32, + tnLinkOamTotalFramePeriodsErrors Counter64, + tnLinkOamTotalFramePerioderrorEvents Counter32, + tnLinkOamSymbolPeriodErrorEventTimestamp TimeStamp, + tnLinkOamSymbolPeriodErrorEventWindow Counter64, + tnLinkOamSymbolPeriodErrorEventThreshold Counter64, + tnLinkOamSymbolPeriodsErrors Counter64, + tnLinkOamSymbolFramePeriodErrors Counter64, + tnLinkOamTotalSymbolFramePerioderrorEvents Counter32, + tnLinkOamEventSecondsSummaryTimestamp TimeStamp, + tnLinkOamEventSecondsSummaryWindow Counter32, + tnLinkOamEventSecondsSummaryThreshold Counter32, + tnLinkOamEventSecondsSummarysEvents Counter32, + tnLinkOamEventSecondsSummaryErrorTotal Counter32, + tnLinkOamTotalEventSecondsSummaryEventTotal Counter32 + } + +tnLinkOamLocationIndex OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The index of the loacation of the OAM unit event status + accessed. + When the value of index is '1', the table will display + the Event status for the Local OAM unit. While the value + is '2', the table will display the status for the Peer + for the respective port." + ::= { tnLinkOamLinkEventStatusEntry 1 } + +tnLinkOamSequenceNumber OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This two-octet field indicates the total number of + events occurred at the remote end." + ::= { tnLinkOamLinkEventStatusEntry 2 } + +tnLinkOamFrameErrorEventTimestamp OBJECT-TYPE + SYNTAX TimeStamp + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This two-octet field indicates the time reference + when the event was generated, in terms of 100 ms + intervals." + ::= { tnLinkOamLinkEventStatusEntry 3 } + +tnLinkOamFrameErrorEventWindow OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This two-octet field indicates the duration of the + period in terms of 100 ms intervals. + 1) The default value is one second. + 2) The lower bound is one second. + 3) The upper bound is one minute." + ::= { tnLinkOamLinkEventStatusEntry 4 } + +tnLinkOamFrameErrorEventThreshold OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This four-octet field indicates the number of detected + errored frames in the period is required to be equal to + or greater than in order for the event to be generated. + 1) The default value is one frame error. + 2) The lower bound is zero frame errors. + 3) The upper bound is unspecified." + ::= { tnLinkOamLinkEventStatusEntry 5 } + +tnLinkOamFrameErrors OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This four-octet field indicates the number of detected + errored frames in the period." + ::= { tnLinkOamLinkEventStatusEntry 6 } + +tnLinkOamTotalFrameErrors OBJECT-TYPE + SYNTAX Counter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This eight-octet field indicates the sum of errored + frames that have been detected since the OAM sublayer + was reset." + ::= { tnLinkOamLinkEventStatusEntry 7 } + +tnLinkOamTotalFrameErrorEvents OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This four-octet field indicates the number of Errored + Frame Event TLVs that have been generated since the + OAM sublayer was reset." + ::= { tnLinkOamLinkEventStatusEntry 8 } + +tnLinkOamFramePeriodErrorEventTimestamp OBJECT-TYPE + SYNTAX TimeStamp + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This two-octet field indicates the time reference + when the event was generated, in terms of 100 ms + intervals." + ::= { tnLinkOamLinkEventStatusEntry 9 } + +tnLinkOamFramePeriodErrorEventWindow OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This four-octet field indicates the duration of period + in terms of frames." + ::= { tnLinkOamLinkEventStatusEntry 10 } + +tnLinkOamFramePeriodErrorEventThreshold OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This four-octet field indicates the number of errored + frames in the period is required to be equal to or + greater than in order for the event to be generated." + ::= { tnLinkOamLinkEventStatusEntry 11 } + +tnLinkOamFramePeriodsErrors OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This four-octet field indicates the number of frame + errors in the period." + ::= { tnLinkOamLinkEventStatusEntry 12 } + +tnLinkOamTotalFramePeriodsErrors OBJECT-TYPE + SYNTAX Counter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This eight-octet field indicates the sum of frame + errors that have been detected since the OAM sublayer + was reset." + ::= { tnLinkOamLinkEventStatusEntry 13 } + +tnLinkOamTotalFramePerioderrorEvents OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This four-octet field indicates the number of Errored + Frame Period Event TLVs that have been generated since + the OAM sublayer was reset." + ::= { tnLinkOamLinkEventStatusEntry 14 } + +tnLinkOamSymbolPeriodErrorEventTimestamp OBJECT-TYPE + SYNTAX TimeStamp + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This two-octet field indicates the time reference when + the event was generated, in terms of 100 ms intervals." + ::= { tnLinkOamLinkEventStatusEntry 15 } + +tnLinkOamSymbolPeriodErrorEventWindow OBJECT-TYPE + SYNTAX Counter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This eight-octet field indicates the number of symbols + in the period." + ::= { tnLinkOamLinkEventStatusEntry 16 } + +tnLinkOamSymbolPeriodErrorEventThreshold OBJECT-TYPE + SYNTAX Counter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This eight-octet field indicates the number of errored + symbols in the period is required to be equal to or + greater than in order for the event to be generated." + ::= { tnLinkOamLinkEventStatusEntry 17 } + +tnLinkOamSymbolPeriodsErrors OBJECT-TYPE + SYNTAX Counter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This eight-octet field indicates the number of symbol + errors in the period." + ::= { tnLinkOamLinkEventStatusEntry 18 } + +tnLinkOamSymbolFramePeriodErrors OBJECT-TYPE + SYNTAX Counter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This eight-octet field indicates the sum of symbol + errors since the OAM sublayer was reset." + ::= { tnLinkOamLinkEventStatusEntry 19 } + +tnLinkOamTotalSymbolFramePerioderrorEvents OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This four-octet field indicates the number of Errored + Symbol Period Event TLVs that have been generated since + the OAM sublayer was reset." + ::= { tnLinkOamLinkEventStatusEntry 20 } + +tnLinkOamEventSecondsSummaryTimestamp OBJECT-TYPE + SYNTAX TimeStamp + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This two-octet field indicates the time reference when + the event was generated, in terms of 100 ms intervals, + encoded as a 16-bit unsigned integer." + ::= { tnLinkOamLinkEventStatusEntry 21 } + +tnLinkOamEventSecondsSummaryWindow OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This two-octet field indicates the duration of the + period in terms of 100 ms intervals, encoded as a + 16-bit unsigned integer." + ::= { tnLinkOamLinkEventStatusEntry 22 } + +tnLinkOamEventSecondsSummaryThreshold OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This two-octet field indicates the number of errored + frame seconds in the period is required to be equal + to or greater than in order for the event to be + generated, encoded as a 16-bit unsigned integer." + ::= { tnLinkOamLinkEventStatusEntry 23 } + +tnLinkOamEventSecondsSummarysEvents OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This two-octet field indicates the number of errored + frame seconds in the period, encoded as a 16-bit + unsigned integer." + ::= { tnLinkOamLinkEventStatusEntry 24 } + +tnLinkOamEventSecondsSummaryErrorTotal OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This four-octet field indicates the sum of errored + frame seconds that have been detected since the OAM + sublayer was reset." + ::= { tnLinkOamLinkEventStatusEntry 25 } + +tnLinkOamTotalEventSecondsSummaryEventTotal OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This four-octet field indicates the number of Errored + Frame Seconds Summary Event TLVs that have been generated + since the OAM sublayer was reset, encoded as a 32bit + unsigned integer." + ::= { tnLinkOamLinkEventStatusEntry 26 } +END |