diff options
| author | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
|---|---|---|
| committer | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
| commit | 98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch) | |
| tree | 9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/teleste | |
| download | mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.tar.gz mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.zip | |
Diffstat (limited to 'MIBS/teleste')
| -rw-r--r-- | MIBS/teleste/TELESTE-COMMON-MIB | 1888 | ||||
| -rw-r--r-- | MIBS/teleste/TELESTE-LUMINATO-MIB | 4030 | ||||
| -rw-r--r-- | MIBS/teleste/TELESTE-LUMINATO-MIB2 | 2817 | ||||
| -rw-r--r-- | MIBS/teleste/TELESTE-ROOT-MIB | 206 |
4 files changed, 8941 insertions, 0 deletions
diff --git a/MIBS/teleste/TELESTE-COMMON-MIB b/MIBS/teleste/TELESTE-COMMON-MIB new file mode 100644 index 0000000..f559122 --- /dev/null +++ b/MIBS/teleste/TELESTE-COMMON-MIB @@ -0,0 +1,1888 @@ +-- +-- TELESTE-COMMON-MIB.mib +-- MIB generated by MG-SOFT Visual MIB Builder Version 4.0 Build 349 +-- Friday, May 02, 2008 at 09:31:32 +-- + +-- ***************************************************************************** +-- Copyright (c) 2000-2008 by: +-- +-- Teleste Corporation +-- Seponkatu 1 +-- FIN-20660 Littoinen, Finland +-- tel. +358 2 2605 611 +-- url: http://www.teleste.com +-- +-- Description: Common objects for all Teleste products +-- +-- Revision History: +-- ----------------- +-- 1.47 26.3.2008 Matti Susi +-- - added product key control objects +-- - added geographical coordinate objects +-- +-- 1.46 22.2.2008 Matti Susi +-- - added new enumeration values to statusSw and statusSettings +-- +-- 1.45 28.5.2007 Matti Susi +-- - added object statusSettings +-- +-- 1.44 30.11.2006 Matti Susi +-- - added moduleSWUpdate Table +-- - added totalUptime and resetCount objects +-- +-- 1.43 13.6.2006 Matti Susi +-- - added statusHw and statusSw objects +-- +-- 1.42 12.4.2006 Matti Susi +-- - added statusTemperature and statusFan objects +-- +-- 1.41 1.4.2003 Matti Susi +-- - added object controlInternalAppAccess for BXX function +-- control +-- +-- 1.40 13.9.2002 Matti Susi +-- - moduleId SYNTAX changed to INTEGER +-- +-- 1.32 7.8.2002 Matti Susi +-- - Some editorial changes +-- - Note: SNMPc network manager requires an index object +-- with size definitions in every SEQUENCE definition. +-- This must be done manually after creating the MIB with +-- MIB builder! +-- +-- 1.31 13.5.2002 Matti Susi +-- - trap delay object inserted +-- +-- 1.3 9.1.2002 Matti Susi +-- - module temperature limits inserted to moduleControlTable +-- - trap and alarm control objects inserted +-- - several objects changed to optional +-- +-- 1.21 18.12.2001 Matti Susi +-- - editorial changes +-- +-- 1.2 05.11.2001 Rainer Salminen +-- - added repairIndex and changed indexing of repairLogTable. +-- +-- 1.1 2.11.2001 Pasi Pöri +-- - trapEnryId added to elementTrapReceiverTable as index +-- in order to enable multiple null IP addresses (0.0.0.0). +-- Thus no table row manipulation is needed. +-- - Specified LMT status info more accurately . +-- +-- 1.0 11.10.2001 Rainer Salminen +-- - Initial release (revised version of TELESTE-GENDATA-MIB) +-- +-- **************************************************************************** +-- + + TELESTE-COMMON-MIB DEFINITIONS ::= BEGIN + + IMPORTS + OBJECT-TYPE + FROM RFC-1212 + IpAddress, Counter + FROM RFC1155-SMI + DisplayString + FROM RFC1213-MIB + common, TPhysAddress, Uint16, DateAndTime + FROM TELESTE-ROOT-MIB; + + + +-- +-- Node definitions +-- + +-- Common element definition +-- +-- An element is a common name for the managed device or system. +-- It is a concept that corresponds to a network node or a network +-- element in general. +-- +-- An element can be a single device system or it can be a modular +-- system in which case it consists of several modules. The module +-- in the system that instruments this MIB is called the main module +-- or the main controller. +-- +-- The word element has this general meaning everywhere in this +-- document. +-- + -- 1.3.6.1.4.1.3715.99.1 + element OBJECT IDENTIFIER ::= { common 1 } + + +-- This section contains element's common identification, classification +-- and configuration information. +-- + -- 1.3.6.1.4.1.3715.99.1.1 + elementInformation OBJECT IDENTIFIER ::= { element 1 } + + + -- 1.3.6.1.4.1.3715.99.1.1.1 + elementName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "This is the logical name of the controlling module of + the network element. The name may or may not be the same + as the module's name in the moduleTable." + ::= { elementInformation 1 } + + + -- 1.3.6.1.4.1.3715.99.1.1.2 + elementStructure OBJECT-TYPE + SYNTAX INTEGER + { + unknown(1), + compact(2), + modular(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This object tells whether the device is a single compact + device or a modular device." + ::= { elementInformation 2 } + + + -- 1.3.6.1.4.1.3715.99.1.1.3 + elementConfigChangeCode OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS optional + DESCRIPTION + "This object is an indicator about changes in the network + element configuration. How the value is formed is device + dependent. It can be a counter, a checksum of the device + configuration parameters, a DateAndTime type variable or + even SysUptime, if no other information is available. + DateAndTime is the recommended value. + + This object is intended to permit a management application + to maintain configuration (including moduleTable) + syncronization with the agent." + ::= { elementInformation 3 } + + + -- 1.3.6.1.4.1.3715.99.1.1.4 + elementResetCount OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS optional + DESCRIPTION + "Total number of software resets during the device's life time." + ::= { elementInformation 4 } + + + -- 1.3.6.1.4.1.3715.99.1.1.5 + elementTotalUpTime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The total uptime the device (software) has been running. Unit 1 day." + ::= { elementInformation 5 } + + + -- 1.3.6.1.4.1.3715.99.1.1.6 + elementLatitude OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS optional + DESCRIPTION + "Device latitude coordinate. Unit 0.00001 degrees." + ::= { elementInformation 6 } + + + -- 1.3.6.1.4.1.3715.99.1.1.7 + elementLongitude OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS optional + DESCRIPTION + "Device longitude coordinate. Unit 0.00001 degrees." + ::= { elementInformation 7 } + + + -- 1.3.6.1.4.1.3715.99.1.1.8 + elementAltitude OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS optional + DESCRIPTION + "Device altitude coordinate. Unit 1 metre." + ::= { elementInformation 8 } + + +-- This section contains element's general status objects. +-- + -- 1.3.6.1.4.1.3715.99.1.2 + elementStatus OBJECT IDENTIFIER ::= { element 2 } + + + -- 1.3.6.1.4.1.3715.99.1.2.1 + statusGeneral OBJECT-TYPE + SYNTAX INTEGER + { + normal(1), + notification(2), + warning(3), + alarm(4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A number stating the general status of the element. + + Values: + 1 = Normal + 2 = At least one Notification is active + 3 = At least one Warning is active + 4 = At least one Alarm is active + + If the element has more than one state active, then + the state with the highest value is returned." + ::= { elementStatus 1 } + + + -- 1.3.6.1.4.1.3715.99.1.2.2 + statusBusMaster OBJECT-TYPE + SYNTAX INTEGER + { + slaveOnly(1), + configuredSlave(2), + currentlySlave(3), + currentlyMaster(4) + } + ACCESS read-only + STATUS optional + DESCRIPTION + "A number stating the Bus Master status of the NE. + + Values: + 1 = The NE is a slave-only device + 2 = The NE is configured as slave + 3 = The NE is configured as master but is currently + slave because a stronger master is on the bus + 4 = The NE is currently the bus master" + ::= { elementStatus 2 } + + + -- 1.3.6.1.4.1.3715.99.1.2.3 + statusLmt OBJECT-TYPE + SYNTAX INTEGER + { + noLmtInterface(1), + stateUnknown(2), + notConnected(3), + connected(4) + } + ACCESS read-only + STATUS optional + DESCRIPTION + "A number telling if the Local Management Terminal (LMT) + is connected to the element. + + Values: + 1 = The element does not have an LMT interface + 2 = The element can not detect if an LMT is connected + 3 = The element has not detected a connected LMT + 4 = The element has detected a connected LMT + + Note! Applies only to fysically point-to-point + connected LMT's to device, not via bus ot other + shared medias." + ::= { elementStatus 3 } + + + -- 1.3.6.1.4.1.3715.99.1.2.4 + statusLid OBJECT-TYPE + SYNTAX INTEGER + { + noLid(1), + closed(2), + open(3) + } + ACCESS read-only + STATUS optional + DESCRIPTION + "Element lid status: + 1 = no lid (no lid sensor is available) + 2 = lid is closed + 3 = lid is open" + ::= { elementStatus 4 } + + + -- 1.3.6.1.4.1.3715.99.1.2.5 + statusTemperature OBJECT-TYPE + SYNTAX INTEGER + { + tempNormal(1), + tempHIHI(2), + tempHi(3), + tempLo(4), + tempLOLO(5) + } + ACCESS read-only + STATUS optional + DESCRIPTION + "Element temperature status: + 1 = normal + 2 = HIHI + 3 = Hi + 4 = Lo + 5 = LOLO + " + ::= { elementStatus 5 } + + + -- 1.3.6.1.4.1.3715.99.1.2.6 + statusFan OBJECT-TYPE + SYNTAX INTEGER + { + fanNormal(1), + fanFailure(2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A common status object for all fans in the device. + fanNormal(1) = all fans operate normally + fanFailure(2) = at least one fan has a failure" + ::= { elementStatus 6 } + + + -- 1.3.6.1.4.1.3715.99.1.2.7 + statusHardware OBJECT-TYPE + SYNTAX INTEGER + { + hwNormal(1), + hwFailure(2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Device hardware status: + hwNormal(1) = the hardware operates normally + hwFailure(2) = a hardware failure is detected" + ::= { elementStatus 7 } + + + -- 1.3.6.1.4.1.3715.99.1.2.8 + statusSoftware OBJECT-TYPE + SYNTAX INTEGER + { + swNormal(1), + swFailure(2), + swMissing(3), + swInitialising(4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Device software status: + swNormal(1) = the software operates normally + swFailure(2) = a software failure is detected + swMissing(3) = the software or firmware is missing + sw(Initialising(4) = the software is initialising" + ::= { elementStatus 8 } + + + -- 1.3.6.1.4.1.3715.99.1.2.9 + statusSettings OBJECT-TYPE + SYNTAX INTEGER + { + settingsStable(1), + settingsChanged(2), + settingsNotAvailable(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Status of device settings: + settingsStable(1) = settings are stable + settingsChanged(2) = settings have been (recently) changed + settingsNotAvailable(3) = settings status is not available + The value should stay in value 2 only a predefined time, e.g. 60 seconds or + the time it takes until the settings are written into non-volatile memory. + " + ::= { elementStatus 9 } + + +-- This section contains element's common control parameters. +-- + -- 1.3.6.1.4.1.3715.99.1.3 + elementControl OBJECT IDENTIFIER ::= { element 3 } + + + -- 1.3.6.1.4.1.3715.99.1.3.1 + controlResetElement OBJECT-TYPE + SYNTAX INTEGER + { + noReset(1), + hardReset(2), + softReset(3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "On write requests this object commands the module to + reset itself. + + If softReset(3) or hardReset(2) can not be performed, + then BAD VALUE error is returned. + + On read requests value noReset(1) is returned." + ::= { elementControl 1 } + + + -- 1.3.6.1.4.1.3715.99.1.3.2 + controlBusMasterAdminState OBJECT-TYPE + SYNTAX INTEGER + { + master(1), + slave(2) + } + ACCESS read-write + STATUS optional + DESCRIPTION + "This object tells whether the element is configured as + a bus master or not. Only relevant for bus master type + of elements. Others return no(2)." + ::= { elementControl 2 } + + + -- 1.3.6.1.4.1.3715.99.1.3.3 + controlAlarmDetection OBJECT-TYPE + SYNTAX INTEGER + { + disabled(1), + enabled(2), + restart(3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "This variable is used to disable or enable the element + alarm checking. When disabled(1), the element + will not check any alarms (or send traps). + Default value is enabled(2). + + Note: This variable must be consistent with + commonAlarmDetectionControl in SCTE-HMS-COMMON-MIB, if + that is implemented." + ::= { elementControl 3 } + + + -- 1.3.6.1.4.1.3715.99.1.3.4 + controlMaxNumberTrapReceivers OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Number of entries in the elementTrapReceiverTable. + At least one trap entry must be supported." + ::= { elementControl 4 } + + + -- 1.3.6.1.4.1.3715.99.1.3.5 + controlTrapReceiverTable OBJECT-TYPE + SYNTAX SEQUENCE OF ControlTrapReceiverEntry + ACCESS not-accessible + STATUS optional + DESCRIPTION + "A table of manager trap receiver addresses, ports and + communities. Total number of entries can not exceed + elementNumberTrapReceivers. An entry is deleted from this + table by setting its IP address to '0.0.0.0'. + + Note: one of the community strings must match to + commonTrapCommunityString in SCTE-HMS-COMMON-MIB, if + that is implemented." + ::= { elementControl 5 } + + + -- 1.3.6.1.4.1.3715.99.1.3.5.1 + controlTrapReceiverEntry OBJECT-TYPE + SYNTAX ControlTrapReceiverEntry + ACCESS not-accessible + STATUS optional + INDEX { receiverEntryId } + ::= { controlTrapReceiverTable 1 } + + + ControlTrapReceiverEntry ::= + SEQUENCE { + receiverEntryId + INTEGER, + receiverAddress + IpAddress, + receiverPort + INTEGER, + receiverCommunity + DisplayString + } + + -- 1.3.6.1.4.1.3715.99.1.3.5.1.1 + receiverEntryId OBJECT-TYPE + SYNTAX INTEGER (1..255) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Unique table index. Makes possible to have several + ip-address of 0.0.0.0 entries so that no mechanism + for row manipulation of table is needed." + ::= { controlTrapReceiverEntry 1 } + + + -- 1.3.6.1.4.1.3715.99.1.3.5.1.2 + receiverAddress OBJECT-TYPE + SYNTAX IpAddress + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Ip address of the manager receiving Traps." + ::= { controlTrapReceiverEntry 2 } + + + -- 1.3.6.1.4.1.3715.99.1.3.5.1.3 + receiverPort OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Trap UDP port number. Default port is the standard trap + port 162." + ::= { controlTrapReceiverEntry 3 } + + + -- 1.3.6.1.4.1.3715.99.1.3.5.1.4 + receiverCommunity OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Community string for the trap receiver. + + The agent is allowed to limit the length of the string. + Minimum length of eight characters must be supported. + + Note: one of the community strings must match to + commonTrapCommunityString in SCTE-HMS-COMMON-MIB, if + that is implemented." + ::= { controlTrapReceiverEntry 4 } + + + -- 1.3.6.1.4.1.3715.99.1.3.6 + controlTrapSending OBJECT-TYPE + SYNTAX INTEGER + { + enabled(1), + disabled(2) + } + ACCESS read-write + STATUS optional + DESCRIPTION + "Enables/disables trap sending. + + 1 = traps enabled + 2 = traps disabled" + ::= { elementControl 6 } + + + -- 1.3.6.1.4.1.3715.99.1.3.7 + controlTrapInterval OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS optional + DESCRIPTION + "The minimum interval between traps. + - Unit 10 milliseconds + - Minimum value 0 (send as fast as possible) + - Maximum value 1000 (10 seconds) + - Default value is 100 (1 second)" + ::= { elementControl 7 } + + + -- 1.3.6.1.4.1.3715.99.1.3.8 + controlTrapLifeTime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS optional + DESCRIPTION + "The maximum time a trap stays in the trap queue waiting + for sending. + - Unit 1 second. + - Minimum value 10 + - Maximum value 300 + - Default value 60" + ::= { elementControl 8 } + + + -- 1.3.6.1.4.1.3715.99.1.3.9 + controlAlarmOnDelay OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS optional + DESCRIPTION + "The minimum time an object's alarm/warning condition must + exist before it is recorded as an alarm/warning. Common + to all alarms/warnings + - Unit 10 ms + - Minimum value 10 (100 ms) + - Maximum value 6000 (60 seconds) + - Default value 100 (1 second)" + ::= { elementControl 9 } + + + -- 1.3.6.1.4.1.3715.99.1.3.10 + controlAlarmOffDelay OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS optional + DESCRIPTION + "The minimum time an alarm/warning entry stays active after + the object has reached it's normal condition. Common to all + alarms/warnings. + - Unit 10 ms + - Minimum value 10 (100 ms) + - Maximum value 6000 (60 seconds) + - default value 100 (1 second)" + ::= { elementControl 10 } + + + -- 1.3.6.1.4.1.3715.99.1.3.11 + controlTrapDelay OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS optional + DESCRIPTION + "The time before a trap is sent after an alarm + is detected. + + - Unit 10 ms + - Minimum value 10 (100 ms) + - Maximum value 6000 (60 seconds) + - Default value 500 (5 seconds) + + This parameter can be used to control alarm storms e.g. + in an amplifier cascade by using a different value in + each amplifier." + ::= { elementControl 11 } + + +-- This section contains element's product key parameters + -- 1.3.6.1.4.1.3715.99.1.4 + elementProductKey OBJECT IDENTIFIER ::= { element 4 } + + + -- 1.3.6.1.4.1.3715.99.1.4.4 + productKeyNumberOfKeys OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS optional + DESCRIPTION + "Number of product keys supported by the device." + ::= { elementProductKey 4 } + + + -- 1.3.6.1.4.1.3715.99.1.4.5 + productKeyTable OBJECT-TYPE + SYNTAX SEQUENCE OF ProductKeyEntry + ACCESS not-accessible + STATUS mandatory + ::= { elementProductKey 5 } + + + -- 1.3.6.1.4.1.3715.99.1.4.5.1 + productKeyEntry OBJECT-TYPE + SYNTAX ProductKeyEntry + ACCESS not-accessible + STATUS mandatory + INDEX { productKeyIndex } + ::= { productKeyTable 1 } + + + ProductKeyEntry ::= + SEQUENCE { + productKeyIndex + INTEGER, + productKeyValue + OCTET STRING, + productKeyMask + OCTET STRING, + productKeyStatus + INTEGER, + productKeyCipher + INTEGER, + productKeyNumberOfFeatures + INTEGER + } + + -- 1.3.6.1.4.1.3715.99.1.4.5.1.1 + productKeyIndex OBJECT-TYPE + SYNTAX INTEGER (1..16) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Product key index." + ::= { productKeyEntry 1 } + + + -- 1.3.6.1.4.1.3715.99.1.4.5.1.2 + productKeyValue OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Product key value." + ::= { productKeyEntry 2 } + + + -- 1.3.6.1.4.1.3715.99.1.4.5.1.3 + productKeyMask OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Product key mask." + ::= { productKeyEntry 3 } + + + -- 1.3.6.1.4.1.3715.99.1.4.5.1.4 + productKeyStatus OBJECT-TYPE + SYNTAX INTEGER + { + keyInvalid(1), + keyValid(2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Product key status: + 1(keyInvalid) = the key is invalid or missing + 2(keyValid) = the key is valid" + ::= { productKeyEntry 4 } + + + -- 1.3.6.1.4.1.3715.99.1.4.5.1.5 + productKeyCipher OBJECT-TYPE + SYNTAX INTEGER + { + cipherOther(1), + cipherBlowFish(2), + cipherXXTEA(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Cipher method supported by this key: + 1(cipherOther) = other ciphering is used + 2(cipherBlowFish) = BlowFish ciphering is used + 3(cipherXXTEA) = XXTEA ciphering is used" + ::= { productKeyEntry 5 } + + + -- 1.3.6.1.4.1.3715.99.1.4.5.1.6 + productKeyNumberOfFeatures OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Number of features available with this key." + ::= { productKeyEntry 6 } + + + -- 1.3.6.1.4.1.3715.99.1.4.6 + productKeyFeatureTable OBJECT-TYPE + SYNTAX SEQUENCE OF ProductKeyFeatureEntry + ACCESS not-accessible + STATUS mandatory + ::= { elementProductKey 6 } + + + -- 1.3.6.1.4.1.3715.99.1.4.6.1 + productKeyFeatureEntry OBJECT-TYPE + SYNTAX ProductKeyFeatureEntry + ACCESS not-accessible + STATUS mandatory + INDEX { productKeyIndex, productKeyFeatureIndex } + ::= { productKeyFeatureTable 1 } + + + ProductKeyFeatureEntry ::= + SEQUENCE { + productKeyFeatureIndex + INTEGER, + productKeyFeatureName + OCTET STRING, + productKeyFeatureEnable + INTEGER, + productKeyFeatureExpirationTime + INTEGER + } + + -- 1.3.6.1.4.1.3715.99.1.4.6.1.1 + productKeyFeatureIndex OBJECT-TYPE + SYNTAX INTEGER (1..32) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Feature index (second index)." + ::= { productKeyFeatureEntry 1 } + + + -- 1.3.6.1.4.1.3715.99.1.4.6.1.2 + productKeyFeatureName OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A human-readable description of the feature." + ::= { productKeyFeatureEntry 2 } + + + -- 1.3.6.1.4.1.3715.99.1.4.6.1.3 + productKeyFeatureEnable OBJECT-TYPE + SYNTAX INTEGER + { + featureDisable(1), + featureEnable(2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Status of the feature: + 1(featureDisable) = the feature si disabled in this device + 2(featureEnable) = the feature is enabled in this devices" + ::= { productKeyFeatureEntry 3 } + + + -- 1.3.6.1.4.1.3715.99.1.4.6.1.4 + productKeyFeatureExpirationTime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Number of days left before the feature expires. A zero value means + infinite validity time. This object has a meaning only if the + feature is enabled (productKeyFeatureEnable = 2(featureEnable))." + ::= { productKeyFeatureEntry 4 } + + +-- Common module definition +-- +-- The element consists of one or more modules. Module parameters are +-- collected into several module tables. Each module has one entry +-- in these tables. If the element is a single device, then the tables +-- have only one entry, which is the element itself. +-- +-- Modules are identified within the element with a unique moduleId. +-- See the moduleId description for more information. +-- + -- 1.3.6.1.4.1.3715.99.2 + module OBJECT IDENTIFIER ::= { common 2 } + + +-- This section contains the element's identification objects +-- and other common element information. +-- + -- 1.3.6.1.4.1.3715.99.2.1 + moduleInformation OBJECT IDENTIFIER ::= { module 1 } + + +-- +-- The moduleTable table shows basic module data of the element. +-- Every plug-in module is represented as an entry in the Table. +-- If the element is not modular, only the first row is present. +-- + -- 1.3.6.1.4.1.3715.99.2.1.1 + moduleTable OBJECT-TYPE + SYNTAX SEQUENCE OF ModuleEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "This table lists basic module identification and + configuration data of modules installed inside + the managed element. + + The first row in the table list information about the + element itself. If the element is not modular, only the + first row exists in the table. + + Object moduleId is used for indexing the modules + in all module section tables." + ::= { moduleInformation 1 } + + + -- 1.3.6.1.4.1.3715.99.2.1.1.1 + moduleEntry OBJECT-TYPE + SYNTAX ModuleEntry + ACCESS not-accessible + STATUS mandatory + INDEX { moduleId } + ::= { moduleTable 1 } + + + ModuleEntry ::= + SEQUENCE { + moduleId + INTEGER, + moduleName + DisplayString, + moduleHwType + DisplayString, + moduleRackNo + INTEGER, + moduleSlotNo + INTEGER + } + + -- 1.3.6.1.4.1.3715.99.2.1.1.1.1 + moduleId OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "An unique module index identifying the (physical) modules + inside the network element. The exact conjunction between + the index and the physical modules depends on the element + structural principle. + + For network elements containing plug-in modules the index + should follow module slot numbering. + + This index should be used in all subsequent module tables." + ::= { moduleEntry 1 } + + + -- 1.3.6.1.4.1.3715.99.2.1.1.1.2 + moduleName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS optional + DESCRIPTION + "The identification name ('aliasname') of the module." + ::= { moduleEntry 2 } + + + -- 1.3.6.1.4.1.3715.99.2.1.1.1.3 + moduleHwType OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The hardware type name of the module." + ::= { moduleEntry 3 } + + + -- 1.3.6.1.4.1.3715.99.2.1.1.1.4 + moduleRackNo OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS optional + DESCRIPTION + "Rack number of the module. + + This can be used to identify the physical position of + the module in the case where the agent manages modules + that are in several racks." + ::= { moduleEntry 4 } + + + -- 1.3.6.1.4.1.3715.99.2.1.1.1.5 + moduleSlotNo OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS optional + DESCRIPTION + "Slot number of the module (within rack)." + ::= { moduleEntry 5 } + + +-- +-- This table shows detailed module data of the element. +-- Every plug-in module is represented as a row in the Table. +-- If the element is not modular, only one row is present. +-- + -- 1.3.6.1.4.1.3715.99.2.1.2 + moduleDetailTable OBJECT-TYPE + SYNTAX SEQUENCE OF ModuleDetailEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "This table lists detailed module data of modules installed + inside the element. + + The first row in the table list information about the + element itself. If the element is not modular, only the + first row exists in the table." + ::= { moduleInformation 2 } + + + -- 1.3.6.1.4.1.3715.99.2.1.2.1 + moduleDetailEntry OBJECT-TYPE + SYNTAX ModuleDetailEntry + ACCESS not-accessible + STATUS mandatory + INDEX { moduleId } + ::= { moduleDetailTable 1 } + + + ModuleDetailEntry ::= + SEQUENCE { + moduleMacAddress + TPhysAddress, + moduleBusAddress + INTEGER, + moduleAppDate + DateAndTime, + moduleAppVersion + DisplayString, + moduleBiosDate + DateAndTime, + moduleBiosVersion + DisplayString, + moduleHwSerialNumber + DisplayString, + moduleHwVersion + DisplayString + } + + -- 1.3.6.1.4.1.3715.99.2.1.2.1.1 + moduleMacAddress OBJECT-TYPE + SYNTAX TPhysAddress + ACCESS read-only + STATUS optional + DESCRIPTION + "Module MAC address. If the MAC address is unknown + '00.00.00.00.00.00' is returned." + ::= { moduleDetailEntry 1 } + + + -- 1.3.6.1.4.1.3715.99.2.1.2.1.2 + moduleBusAddress OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS optional + DESCRIPTION + "Module bus address." + ::= { moduleDetailEntry 2 } + + + -- 1.3.6.1.4.1.3715.99.2.1.2.1.3 + moduleAppDate OBJECT-TYPE + SYNTAX DateAndTime + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Module application software date." + ::= { moduleDetailEntry 3 } + + + -- 1.3.6.1.4.1.3715.99.2.1.2.1.4 + moduleAppVersion OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Module application software version. If software version + is undefined, then zero length string is returned." + ::= { moduleDetailEntry 4 } + + + -- 1.3.6.1.4.1.3715.99.2.1.2.1.5 + moduleBiosDate OBJECT-TYPE + SYNTAX DateAndTime + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Module BIOS date." + ::= { moduleDetailEntry 5 } + + + -- 1.3.6.1.4.1.3715.99.2.1.2.1.6 + moduleBiosVersion OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Module BIOS version. If bios version is undefined, + a zero length string is returned." + ::= { moduleDetailEntry 6 } + + + -- 1.3.6.1.4.1.3715.99.2.1.2.1.7 + moduleHwSerialNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Module serial number." + ::= { moduleDetailEntry 7 } + + + -- 1.3.6.1.4.1.3715.99.2.1.2.1.8 + moduleHwVersion OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Module hardware version." + ::= { moduleDetailEntry 8 } + + +-- This section contains status information of the modules +-- of the element. +-- + -- 1.3.6.1.4.1.3715.99.2.2 + moduleStatus OBJECT IDENTIFIER ::= { module 2 } + + +-- +-- This table contains common status objects for all +-- modules inside the element. +-- + -- 1.3.6.1.4.1.3715.99.2.2.1 + moduleStatusTable OBJECT-TYPE + SYNTAX SEQUENCE OF ModuleStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "This table contains status objects for modules inside + the network element.The first row in the table lists + information about the host module. If the element is + not modular, only the first row exists in the table." + ::= { moduleStatus 1 } +-- +-- A table of common status objects for all modules. +-- + + -- 1.3.6.1.4.1.3715.99.2.2.1.1 + moduleStatusEntry OBJECT-TYPE + SYNTAX ModuleStatusEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Row in moduleStatusTable. The index is moduleId from + the moduleTable. Row in this table exist only if + there is a row with the same moduleId in the moduleTable." + INDEX { moduleId } + ::= { moduleStatusTable 1 } + + + ModuleStatusEntry ::= + SEQUENCE { + statusResetCause + INTEGER, + statusRunningSwImage + INTEGER, + statusInternalTemperature + INTEGER, + statusLidStatus + INTEGER, + statusRestartCounter + Counter + } + + -- 1.3.6.1.4.1.3715.99.2.2.1.1.1 + statusResetCause OBJECT-TYPE + SYNTAX INTEGER + { + unknown(1), + selfReset(2), + powerReset(3), + commandedReset(4), + softdownloadReset(5) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Reason for the last reset. + + If the reason is unknown, the value is reasonUnknown(1). + If the device makes self reset and it can detect it, then + value is reasonSelfReset(2). If the reset was made by the + user from the power switch and it can be sensed, then the + value is reasonPowerReset(3). If the reason is an external + command from the user interface or from the network + message (e.g. commonReset), then the reason is + reasonCommandedReset(4)." + ::= { moduleStatusEntry 1 } + + + -- 1.3.6.1.4.1.3715.99.2.2.1.1.2 + statusRunningSwImage OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Currently running software image number. + Bios is 0, applications are numbered from 1..n, + where n is the maximum image number." + ::= { moduleStatusEntry 2 } + + + -- 1.3.6.1.4.1.3715.99.2.2.1.1.3 + statusInternalTemperature OBJECT-TYPE + SYNTAX INTEGER (-600..1300) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Device temperature, unit 0.1 deg C. Value is zero (0), + if temperature is not available." + ::= { moduleStatusEntry 3 } + + + -- 1.3.6.1.4.1.3715.99.2.2.1.1.4 + statusLidStatus OBJECT-TYPE + SYNTAX INTEGER + { + noLid(1), + closed(2), + open(3) + } + ACCESS read-only + STATUS optional + DESCRIPTION + "Current lid status detected by the device. May or may not be + the same variable as the elementLidStatus." + ::= { moduleStatusEntry 4 } + + + -- 1.3.6.1.4.1.3715.99.2.2.1.1.5 + statusRestartCounter OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS optional + DESCRIPTION + "This objects counts the number of restarts of the module. + A start can be a cold start or a warm start." + ::= { moduleStatusEntry 5 } +-- +-- + +-- This section contains control entities of the modules +-- of the element. +-- + -- 1.3.6.1.4.1.3715.99.2.3 + moduleControl OBJECT IDENTIFIER ::= { module 3 } + + +-- +-- + -- 1.3.6.1.4.1.3715.99.2.3.1 + moduleControlTable OBJECT-TYPE + SYNTAX SEQUENCE OF ModuleControlEntry + ACCESS not-accessible + STATUS optional + DESCRIPTION + "This table contains common control commands for all the + modules inside the element." + ::= { moduleControl 1 } + + + -- 1.3.6.1.4.1.3715.99.2.3.1.1 + moduleControlEntry OBJECT-TYPE + SYNTAX ModuleControlEntry + ACCESS not-accessible + STATUS optional + INDEX { moduleId } + ::= { moduleControlTable 1 } + + + ModuleControlEntry ::= + SEQUENCE { + controlLedUsage + INTEGER, + controlMarkState + INTEGER, + controlReset + INTEGER, + controlTempLimitHiHi + INTEGER, + controlTempLimitHi + INTEGER, + controlTempLimitLo + INTEGER, + controlTempLimitLoLo + INTEGER, + controlTempDeadBand + INTEGER, + controlInternalAppAccess + INTEGER, + controlLocalAccess + INTEGER + } + + -- 1.3.6.1.4.1.3715.99.2.3.1.1.1 + controlLedUsage OBJECT-TYPE + SYNTAX INTEGER + { + notSupported(1), + alwaysOn(2), + offWhenLidClosed(3) + } + ACCESS read-write + STATUS optional + DESCRIPTION + "A variable to instruct how device LED's behave when + the lid is closed." + ::= { moduleControlEntry 1 } + + + -- 1.3.6.1.4.1.3715.99.2.3.1.1.2 + controlMarkState OBJECT-TYPE + SYNTAX INTEGER + { + notSupported(1), + on(2), + off(3) + } + ACCESS read-write + STATUS optional + DESCRIPTION + "A variable to instruct the device to start and stop + showing mark (blinking module LED). + + On read requests returns the current mark state." + ::= { moduleControlEntry 2 } + + + -- 1.3.6.1.4.1.3715.99.2.3.1.1.3 + controlReset OBJECT-TYPE + SYNTAX INTEGER + { + noReset(1), + hardReset(2), + softReset(3) + } + ACCESS read-write + STATUS optional + DESCRIPTION + "On write requests this object commands the module to + reset itself. + + If softReset(3) or hardReset(2) can not be performed, + then BAD VALUE error is returned. + + On read requests value noReset(1) is returned." + ::= { moduleControlEntry 3 } + + + -- 1.3.6.1.4.1.3715.99.2.3.1.1.4 + controlTempLimitHiHi OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS optional + DESCRIPTION + "Module temperature HiHi (high alarm) limit in 0.1 degC." + ::= { moduleControlEntry 4 } + + + -- 1.3.6.1.4.1.3715.99.2.3.1.1.5 + controlTempLimitHi OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS optional + DESCRIPTION + "Module temperature Hi (high warning) limit in 0.1 degC." + ::= { moduleControlEntry 5 } + + + -- 1.3.6.1.4.1.3715.99.2.3.1.1.7 + controlTempLimitLo OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS optional + DESCRIPTION + "Module temperature Lo (low warning) limit in 0.1 degC." + ::= { moduleControlEntry 7 } + + + -- 1.3.6.1.4.1.3715.99.2.3.1.1.8 + controlTempLimitLoLo OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS optional + DESCRIPTION + "Module temperature LoLo (low alarm) limit in 0.1 degC." + ::= { moduleControlEntry 8 } + + + -- 1.3.6.1.4.1.3715.99.2.3.1.1.9 + controlTempDeadBand OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS optional + DESCRIPTION + "Module temperature alarm/warning deadband in 0.1 degC. Common + to all limit values (LoLo, Lo, Hi, HiHi). The deadband defines + the difference between the 'ON' limit and the 'OFF' limit of + the corresponding alarm. + + Example: The Hi limit is 65 degC and the deadband is 5 degC. + The high warning is activated when the temperature exceeds + 65 degC and deactivated only after it falls below 60 degC." + ::= { moduleControlEntry 9 } + + + -- 1.3.6.1.4.1.3715.99.2.3.1.1.10 + controlInternalAppAccess OBJECT-TYPE + SYNTAX INTEGER + { + allowIntControl(1), + denyIntControl(2) + } + ACCESS read-write + STATUS optional + DESCRIPTION + "This object defines whether the internal controller application + is able to access the module parameters. This corresponds + to the BXX module setting 'Allow Functions'. + 1 = allow internal control + 2 = deny internal control (remote control is possible)" + ::= { moduleControlEntry 10 } + + + -- 1.3.6.1.4.1.3715.99.2.3.1.1.11 + controlLocalAccess OBJECT-TYPE + SYNTAX INTEGER + { + disabled(1), + enabled(2) + } + ACCESS read-write + STATUS optional + DESCRIPTION + "This object defines whether the local user interface + (buttons, knobs etc.) is enabled or disabled. Values: + 1 = disabled, local UI is locked + 2 = enabled, local UI is active + For modules/devices with no local UI this objects should + return value 'disabled (1)." + ::= { moduleControlEntry 11 } + + + -- 1.3.6.1.4.1.3715.99.2.3.2 + moduleSWUpdateTable OBJECT-TYPE + SYNTAX SEQUENCE OF ModuleSWUpdateEntry + ACCESS not-accessible + STATUS optional + DESCRIPTION + "A table of software update control objects." + ::= { moduleControl 2 } + + + -- 1.3.6.1.4.1.3715.99.2.3.2.1 + moduleSWUpdateEntry OBJECT-TYPE + SYNTAX ModuleSWUpdateEntry + ACCESS not-accessible + STATUS optional + INDEX { moduleId } + ::= { moduleSWUpdateTable 1 } + + + ModuleSWUpdateEntry ::= + SEQUENCE { + sWUpdateControl + INTEGER, + swUpdateURL + DisplayString, + sWUpdateFileName + DisplayString, + sWUpdateStatus + DisplayString + } + + -- 1.3.6.1.4.1.3715.99.2.3.2.1.1 + sWUpdateControl OBJECT-TYPE + SYNTAX INTEGER + { + updateIdle(1), + updateRunning(2), + updateFailed(3), + updateStart(4) + } + ACCESS read-write + STATUS optional + DESCRIPTION + "Writing value updateStart(4) commands the module to run a software + update. The software image location and file name are specified in + sWUpdateURL and sWUpdateFilename. + + Writing a updateIdle(1) when the update is running will terminate the + update process immediately. Writing any value when no update is + runnign has no effect. + + Reading this object returns either updateIdle(1), updateRunning(2) or + updateFailed(3) depending on the status of the (last) software update. + " + ::= { moduleSWUpdateEntry 1 } + + + -- 1.3.6.1.4.1.3715.99.2.3.2.1.2 + swUpdateURL OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS optional + DESCRIPTION + "The URL where the software image can be downloaded. + + Format e.g. TFTP:\\downloads\swupdate\." + ::= { moduleSWUpdateEntry 2 } + + + -- 1.3.6.1.4.1.3715.99.2.3.2.1.3 + sWUpdateFileName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS optional + DESCRIPTION + "File name of the software image file to be downloaded." + ::= { moduleSWUpdateEntry 3 } + + + -- 1.3.6.1.4.1.3715.99.2.3.2.1.4 + sWUpdateStatus OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS optional + DESCRIPTION + "Description of the software update result. + + After successful update this object should return a string + 'Software updated successfully on <date and time>'. If the update failed + the returned value should be 'Software update failed'. + " + ::= { moduleSWUpdateEntry 4 } + + +-- Module registry consists of one or more tables to store +-- different kind of maintenance or management information. +-- +-- The tables do not affect on the operation of the module. +-- They are used only to support management and they are +-- totally controlled by the manager. +-- + -- 1.3.6.1.4.1.3715.99.2.4 + moduleRegistry OBJECT IDENTIFIER ::= { module 4 } + + + -- 1.3.6.1.4.1.3715.99.2.4.1 + moduleSizeOfTable OBJECT-TYPE + SYNTAX SEQUENCE OF ModuleSizeOfEntry + ACCESS not-accessible + STATUS optional + DESCRIPTION + "This table defines maximum number of entries + in the registry tables. All the registry tables have + fixed size defined in this table." + ::= { moduleRegistry 1 } + + + -- 1.3.6.1.4.1.3715.99.2.4.1.1 + moduleSizeOfEntry OBJECT-TYPE + SYNTAX ModuleSizeOfEntry + ACCESS not-accessible + STATUS optional + INDEX { moduleId } + ::= { moduleSizeOfTable 1 } + + + ModuleSizeOfEntry ::= + SEQUENCE { + sizeOfRegistry + INTEGER, + sizeOfRepairlog + INTEGER, + sizeOfNotebook + INTEGER + } + + -- 1.3.6.1.4.1.3715.99.2.4.1.1.1 + sizeOfRegistry OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Max number of entries in the registryTable. + The entries in the registryTable are numbered + from 1..sizeofRegistry." + ::= { moduleSizeOfEntry 1 } + + + -- 1.3.6.1.4.1.3715.99.2.4.1.1.2 + sizeOfRepairlog OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS optional + DESCRIPTION + "Max number of entries in the repairlogTable. + + First entry (oldest entry) is deleted, when a new + entry is added and the table is full." + ::= { moduleSizeOfEntry 2 } + + + -- 1.3.6.1.4.1.3715.99.2.4.1.1.3 + sizeOfNotebook OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS optional + DESCRIPTION + "Max number of entries in the notebookTable. + The lines in the notebookTable are numbered from + 1..sizeofNotebook." + ::= { moduleSizeOfEntry 3 } + + +-- +-- The moduleRegistryTable contains an indexed data storage +-- for each module. The Manager may use registry data for +-- various purposes. +-- + -- 1.3.6.1.4.1.3715.99.2.4.2 + moduleRegistryTable OBJECT-TYPE + SYNTAX SEQUENCE OF ModuleRegistryEntry + ACCESS not-accessible + STATUS optional + DESCRIPTION + "This table lists user data for all modules + installed inside the element. + + Table is indexed by the moduleId and regIndex. + regIndex can have values 1..sizeofRegistry. + + A registryEntry is 'deleted' by setting its name + to an empty string." + ::= { moduleRegistry 2 } + + + -- 1.3.6.1.4.1.3715.99.2.4.2.1 + moduleRegistryEntry OBJECT-TYPE + SYNTAX ModuleRegistryEntry + ACCESS not-accessible + STATUS optional + INDEX { moduleId, regIndex } + ::= { moduleRegistryTable 1 } + + + ModuleRegistryEntry ::= + SEQUENCE { + regIndex + INTEGER, + regName + DisplayString, + regValue + DisplayString + } + + -- 1.3.6.1.4.1.3715.99.2.4.2.1.1 + regIndex OBJECT-TYPE + SYNTAX INTEGER (1..255) + ACCESS read-only + STATUS optional + DESCRIPTION + "A second index to registryTable. + Can have values 1..sizeofRegistryTable." + ::= { moduleRegistryEntry 1 } + + + -- 1.3.6.1.4.1.3715.99.2.4.2.1.2 + regName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS optional + DESCRIPTION + "Descriptive name for the parameter. + + The agent is allowed to limit the length of the name. + Minimum length of eight characters must be supported. + + Writing empty string to this object removes it from the + registryTable." + ::= { moduleRegistryEntry 2 } + + + -- 1.3.6.1.4.1.3715.99.2.4.2.1.3 + regValue OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS optional + DESCRIPTION + "Textual information describing the parameter information. + + The agent is allowed to limit the length of the name. + Minimum length of eight characters must be supported." + ::= { moduleRegistryEntry 3 } + + + -- 1.3.6.1.4.1.3715.99.2.4.3 + moduleRepairLogTable OBJECT-TYPE + SYNTAX SEQUENCE OF ModuleRepairLogEntry + ACCESS not-accessible + STATUS optional + DESCRIPTION + "This table contains repair history entries for modules + in the element. The table is indexed with moduleId and + repairLogDate. + + The table can have sizeofRepairlog number of entries. + If this number is exceeded when writing a new entry, + the oldest entry is deleted and and a new entry is added." + ::= { moduleRegistry 3 } + + + -- 1.3.6.1.4.1.3715.99.2.4.3.1 + moduleRepairLogEntry OBJECT-TYPE + SYNTAX ModuleRepairLogEntry + ACCESS not-accessible + STATUS optional + DESCRIPTION + "Row entry in RepairLogTable. + + Note that it uses double index: moduleId repairIndex. + that uniquely identify each log entry. Rows for particular + module exist only if there is row, that represents this + module in the moduleTable. + + A row is 'deleted' by giving a date 0000-00-00." + INDEX { moduleId, repairIndex } + ::= { moduleRepairLogTable 1 } + + + ModuleRepairLogEntry ::= + SEQUENCE { + repairIndex + INTEGER, + repairDate + DisplayString, + repairReasonCode + OCTET STRING, + repairNameCode + OCTET STRING, + repairComment + DisplayString + } + + -- 1.3.6.1.4.1.3715.99.2.4.3.1.1 + repairIndex OBJECT-TYPE + SYNTAX INTEGER (1..32767) + ACCESS read-only + STATUS optional + DESCRIPTION + "Row number of the Repairlog entry. Can have values + between 1..sizeOfRepairlog. This field is a second index + to moduleRepairLogTable." + ::= { moduleRepairLogEntry 1 } + + + -- 1.3.6.1.4.1.3715.99.2.4.3.1.2 + repairDate OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS optional + DESCRIPTION + "Date of this repair entry formatted as CCYY-MM-DD." + ::= { moduleRepairLogEntry 2 } + + + -- 1.3.6.1.4.1.3715.99.2.4.3.1.3 + repairReasonCode OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (4)) + ACCESS read-write + STATUS optional + DESCRIPTION + "Repair code for this entry." + ::= { moduleRepairLogEntry 3 } + + + -- 1.3.6.1.4.1.3715.99.2.4.3.1.4 + repairNameCode OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (4)) + ACCESS read-write + STATUS optional + DESCRIPTION + "Repairer name code (initials) for this entry." + ::= { moduleRepairLogEntry 4 } + + + -- 1.3.6.1.4.1.3715.99.2.4.3.1.5 + repairComment OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-write + STATUS optional + DESCRIPTION + "Comment of the repair event. + The agent is allowed to truncate the length of the + comment, if it is too long to internal storage." + ::= { moduleRepairLogEntry 5 } + + + -- 1.3.6.1.4.1.3715.99.2.4.4 + moduleNotebookTable OBJECT-TYPE + SYNTAX SEQUENCE OF ModuleNotebookEntry + ACCESS not-accessible + STATUS optional + DESCRIPTION + "Notebook is a free text area for manager or serviceman + notes. It is divided into 50 character long character + blocks or lines. Each line is an entry in the + notebookTable. + + Indices are moduleName and lineNumber. + + A new line with the same lineNumber overwrites + the old line." + ::= { moduleRegistry 4 } + + + -- 1.3.6.1.4.1.3715.99.2.4.4.1 + moduleNotebookEntry OBJECT-TYPE + SYNTAX ModuleNotebookEntry + ACCESS not-accessible + STATUS optional + INDEX { moduleId, notebookLineNumber } + ::= { moduleNotebookTable 1 } + + + ModuleNotebookEntry ::= + SEQUENCE { + notebookLineNumber + INTEGER, + notebookLineText + OCTET STRING + } + + -- 1.3.6.1.4.1.3715.99.2.4.4.1.1 + notebookLineNumber OBJECT-TYPE + SYNTAX INTEGER (1..255) + ACCESS read-only + STATUS optional + DESCRIPTION + "The line number of the notebookTextLine. + The number must be in between 1..sizeofNotebook. + inclusive. Numbers should be used consecutively." + ::= { moduleNotebookEntry 1 } + + + -- 1.3.6.1.4.1.3715.99.2.4.4.1.2 + notebookLineText OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (0..50)) + ACCESS read-write + STATUS optional + DESCRIPTION + "Text field for storing notes about the module." + ::= { moduleNotebookEntry 2 } + + + + END + +-- +-- TELESTE-COMMON-MIB.mib +-- diff --git a/MIBS/teleste/TELESTE-LUMINATO-MIB b/MIBS/teleste/TELESTE-LUMINATO-MIB new file mode 100644 index 0000000..0482552 --- /dev/null +++ b/MIBS/teleste/TELESTE-LUMINATO-MIB @@ -0,0 +1,4030 @@ +-- +-- TELESTE-LUMINATO-MIB.mib +-- MIB generated by MG-SOFT Visual MIB Builder Version 4.0 Build 349 +-- Wednesday, September 30, 2009 at 14:12:58 +-- +-- TELESTE-LUMINATO-MIB.mib +-- +-- ***************************************************************************** +-- Copyright (c) 2000-2010 by: +-- +-- Teleste Corporation +-- Seponkatu 1 +-- FIN-20660 Littoinen, Finland +-- tel. +358 2 2605 611 +-- url: http://www.teleste.com +-- +-- Description: Objects for Luminato +-- +-- Revision History: +-- ----------------- +-- 1.2 16.02.2010 Sami Salo and Sergey Egorov +-- - Changed OID 1.3.6.1.4.1.3715.17.2 from 'monitor' to 'statusCode' +-- - Corrected types and ranges for PID, SID and TS IDs +-- - Minor cosmetic corrections +-- 1.1 30.09.2009 Rainer Salminen and Sami Salo +-- - Added monitor and alarm object tables +-- 1.0 19.02.2009 Sergey Egorov +-- - Initial release +-- **************************************************************************** +-- + + TELESTE-LUMINATO-MIB DEFINITIONS ::= BEGIN + + IMPORTS + OBJECT-TYPE + FROM RFC-1212 + TimeTicks + FROM RFC1155-SMI + DisplayString + FROM RFC1213-MIB + Unsigned32 + FROM SNMPv2-SMI + luminato + FROM TELESTE-ROOT-MIB + Float + FROM UCD-SNMP-MIB; + + + +-- +-- Node definitions +-- +-- General information of device + -- 1.3.6.1.4.1.3715.17.1 + general OBJECT IDENTIFIER ::= { luminato 1 } + + -- 1.3.6.1.4.1.3715.17.1.1 + deviceName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The identification name ('aliasname') of the device" + ::= { general 1 } + + + -- 1.3.6.1.4.1.3715.17.1.2 + generalStatus OBJECT-TYPE + SYNTAX INTEGER + { + statusAlert(1), + statusCritical(2), + statusError(3), + statusWarning(4), + statusNotice(5), + statusInformational(6), + statusDebug(7) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "General status of device" + ::= { general 2 } + + -- 1.3.6.1.4.1.3715.17.1.3 + redundancyStatus OBJECT-TYPE + SYNTAX INTEGER + { + redundancyStandalone(1), + redundancyMaster(16), + redundancyMasterHandover(24), + redundancyBackup(32), + redundancyBackupHandover(40), + redundancyError(64) + } + MAX-ACCESS read-only + STATUS optional + DESCRIPTION + "Status of device in 1+1 backup operation mode" + ::= { general 3 } + + -- 1.3.6.1.4.1.3715.17.1.10 + hwSerialNumber OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Device serial number" + ::= { general 10 } + + -- 1.3.6.1.4.1.3715.17.1.11 + hwType OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The hardware type name of the device" + ::= { general 11 } + + -- 1.3.6.1.4.1.3715.17.1.12 + hwVersion OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Device hardware version" + ::= { general 12 } + + -- 1.3.6.1.4.1.3715.17.1.13 + swVersion OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Device running software version" + ::= { general 13 } + + -- 1.3.6.1.4.1.3715.17.1.14 + upTime OBJECT-TYPE + SYNTAX TimeTicks + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Device uptime" + ::= { general 14 } + + + -- 1.3.6.1.4.1.3715.17.1.15 + cumulativeUptime OBJECT-TYPE + SYNTAX TimeTicks + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Device cummulative uptime" + ::= { general 15 } + + + -- 1.3.6.1.4.1.3715.17.2 + statusCode OBJECT IDENTIFIER ::= { luminato 2 } + + -- 1.3.6.1.4.1.3715.17.2.1 + interfaceTypeTable OBJECT-TYPE + SYNTAX SEQUENCE OF InterfaceTypeEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "InterfaceTypeTable lists possible interface types in the system." + ::= { statusCode 1 } + + -- 1.3.6.1.4.1.3715.17.2.1.1 + interfaceTypeEntry OBJECT-TYPE + SYNTAX InterfaceTypeEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Each InterfaceTypeEntry describes type of the interface." + INDEX { interfaceTypeId } + ::= { interfaceTypeTable 1 } + + + InterfaceTypeEntry ::= + SEQUENCE { + interfaceTypeId + INTEGER + } + + -- 1.3.6.1.4.1.3715.17.2.1.1.1 + interfaceTypeId OBJECT-TYPE + SYNTAX INTEGER + { + input(1), + output(2) + } + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Interfacetype Id has two values input(1) and output(2). Values are used in other tables as index." + ::= { interfaceTypeEntry 1 } + + -- 1.3.6.1.4.1.3715.17.2.2 + statusCodeDeviceTable OBJECT-TYPE + SYNTAX SEQUENCE OF StatusCodeDeviceEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table describes monitorable objects of the device. + The objects may represents real objects or classes. + The monitoring system or user shall not poll this table to detect device state. + + Instead - user shall wait for traps or poll currentAlarmTable(1.3.6.1.4.1.5591.1.1.2) from SCTE-HMS-PROPERTY-MIB. + In this case statusCodeDeviceTable shall be used to obtains text definition of alarm." + ::= { statusCode 2 } + + -- 1.3.6.1.4.1.3715.17.2.2.1 + statusCodeDeviceEntry OBJECT-TYPE + SYNTAX StatusCodeDeviceEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " " + INDEX { scdObjectId } + ::= { statusCodeDeviceTable 1 } + + + StatusCodeDeviceEntry ::= + SEQUENCE { + scdObjectId + Unsigned32, + scdObjectValue + INTEGER, + scdObjectDescriptor + DisplayString, + scdObjectAlarmValue + INTEGER + } + + -- 1.3.6.1.4.1.3715.17.2.2.1.1 + scdObjectId OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Unique identifier of the monitorable object. + " + ::= { statusCodeDeviceEntry 1 } + + -- 1.3.6.1.4.1.3715.17.2.2.1.2 + scdObjectValue OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Value of the monitorable object. + The scdObjectDescriptor tells name, scale and unit of the object." + ::= { statusCodeDeviceEntry 2 } + + + -- 1.3.6.1.4.1.3715.17.2.2.1.3 + scdObjectDescriptor OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Description of the monitorable object. + + Free text if object has two states + + or + + Format: + Name, Scale, Unit, [optional text] + + ------------------------------------ + + Example 1 (Analogue object): + + 'MainVoltage, 0.01, V' + + Usage: + scdObjectId:7 (example) + scdObjectValue:2399 + scdObjectDescriptor:'MainVoltage, 0.01, V' + + means + + Main voltage is 23.99 V + + ------------------------------------ + + Example 2 (Discrete object): + + 'TemperatureHigh, 1, high(2)/nominal(1), Alarm state of the temperature' + + Usage: + scdObjectId:12 (example) + scdObjectValue:2 + + means + + Temperature is in high alarm state. + + ------------------------------------ + " + ::= { statusCodeDeviceEntry 3 } + + + -- 1.3.6.1.4.1.3715.17.2.2.1.4 + scdObjectAlarmValue OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "When the object has this value it is in the alarm state. + One object id can have only one alarm state. + If more alarm states exist then new associated object needs to be created. + Note that alarm state value can have only discrete values. + If the value is zero then there is no alarm for this object. + + Example: + + TemperatureHigh object can have values high(2) or nominal(1). + Alarm monitoring for this object is triggered by setting dmObjectAlarmValue + to value 2 meaning high(2). + + How the alarm processing is done is out of scope of this MIB. + " + ::= { statusCodeDeviceEntry 4 } + + -- 1.3.6.1.4.1.3715.17.2.3 + statusCodeModuleTable OBJECT-TYPE + SYNTAX SEQUENCE OF StatusCodeModuleEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table describes monitorable objects per module inside the device. + The objects may represents real objects or classes. + The monitoring system or user shall not poll this table to detect device state. + + Instead - user shall wait for traps or poll currentAlarmTable(1.3.6.1.4.1.5591.1.1.2) from SCTE-HMS-PROPERTY-MIB. + In this case statusCodeModuleTable shall be used to obtains text definition of alarm." + ::= { statusCode 3 } + + -- 1.3.6.1.4.1.3715.17.2.3.1 + statusCodeModuleEntry OBJECT-TYPE + SYNTAX StatusCodeModuleEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " " + INDEX { scmModuleId, scmObjectId } + ::= { statusCodeModuleTable 1 } + + + StatusCodeModuleEntry ::= + SEQUENCE { + scmModuleId + INTEGER, + scmObjectId + Unsigned32, + scmObjectValue + INTEGER, + scmObjectDescriptor + DisplayString, + scmObjectAlarmValue + INTEGER + } + + -- 1.3.6.1.4.1.3715.17.2.3.1.1 + scmModuleId OBJECT-TYPE + SYNTAX INTEGER (1..7) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Module Id within the device (usually slot number)." + ::= { statusCodeModuleEntry 1 } + + -- 1.3.6.1.4.1.3715.17.2.3.1.2 + scmObjectId OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Unique identifier of the monitorable object within the module." + ::= { statusCodeModuleEntry 2 } + + + -- 1.3.6.1.4.1.3715.17.2.3.1.3 + scmObjectValue OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Value of the monitorable object. + The scmObjectDescriptor tells name, scale and unit of the object." + ::= { statusCodeModuleEntry 3 } + + + -- 1.3.6.1.4.1.3715.17.2.3.1.4 + scmObjectDescriptor OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Description of the monitorable object. + See scdObjectDescriptor for format, example and usage. + + " + ::= { statusCodeModuleEntry 4 } + + + -- 1.3.6.1.4.1.3715.17.2.3.1.5 + scmObjectAlarmValue OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "See scdObjectAlarmValue for format, example and usage. + + " + ::= { statusCodeModuleEntry 5 } + + + -- 1.3.6.1.4.1.3715.17.2.4 + statusCodeInterfaceTable OBJECT-TYPE + SYNTAX SEQUENCE OF StatusCodeInterfaceEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table describes monitorable objects per interface per module. + The objects may represents real objects or classes. + The monitoring system or user shall not poll this table to detect device state. + + Instead - user shall wait for traps or poll currentAlarmTable(1.3.6.1.4.1.5591.1.1.2) from SCTE-HMS-PROPERTY-MIB. + In this case statusCodeInterfaceTable shall be used to obtains text definition of alarm." + + ::= { statusCode 4 } + + -- 1.3.6.1.4.1.3715.17.2.4.1 + statusCodeInterfaceEntry OBJECT-TYPE + SYNTAX StatusCodeInterfaceEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " " + INDEX { interfaceTypeId, scmModuleId, sciInterfaceId, sciObjectId } + ::= { statusCodeInterfaceTable 1 } + + + StatusCodeInterfaceEntry ::= + SEQUENCE { + sciInterfaceId + INTEGER, + sciObjectId + Unsigned32, + sciObjectValue + INTEGER, + sciObjectDescriptor + DisplayString, + sciObjectAlarmValue + INTEGER + } + + -- 1.3.6.1.4.1.3715.17.2.4.1.1 + sciInterfaceId OBJECT-TYPE + SYNTAX INTEGER (1..4) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Unique interface Id within the module (e.g. RF connector number)." + ::= { statusCodeInterfaceEntry 1 } + + + -- 1.3.6.1.4.1.3715.17.2.4.1.2 + sciObjectId OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Unique identifier of the monitorable object within the interface." + ::= { statusCodeInterfaceEntry 2 } + + -- 1.3.6.1.4.1.3715.17.2.4.1.3 + sciObjectValue OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Value of the monitorable object. + The sciObjectDescriptor tells name, scale and unit of the object." + ::= { statusCodeInterfaceEntry 3 } + + + -- 1.3.6.1.4.1.3715.17.2.4.1.4 + sciObjectDescriptor OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Description of the monitorable object. + See scdObjectDescriptor for format, example and usage. + + " + ::= { statusCodeInterfaceEntry 4 } + + + -- 1.3.6.1.4.1.3715.17.2.4.1.5 + sciObjectAlarmValue OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "See dmObjectAlarmValue for format, example and usage. + + " + ::= { statusCodeInterfaceEntry 5 } + + + -- 1.3.6.1.4.1.3715.17.2.5 + statusCodeTransportStreamTable OBJECT-TYPE + SYNTAX SEQUENCE OF StatusCodeTransportStreamEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table describes monitorable objects of each transport stream. + The objects may represents real objects or classes. + The monitoring system or user shall not poll this table to detect device state. + + Instead - user shall wait for traps or poll currentAlarmTable(1.3.6.1.4.1.5591.1.1.2) from SCTE-HMS-PROPERTY-MIB. + In this case statusCodeTransportStreamTable shall be used to obtains text definition of alarm." + ::= { statusCode 5 } + + -- 1.3.6.1.4.1.3715.17.2.5.1 + statusCodeTransportStreamEntry OBJECT-TYPE + SYNTAX StatusCodeTransportStreamEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " " + INDEX { interfaceTypeId, scmModuleId, sciInterfaceId, sctsTransportStreamId, sctsObjectId + } + ::= { statusCodeTransportStreamTable 1 } + + + StatusCodeTransportStreamEntry ::= + SEQUENCE { + sctsTransportStreamId + INTEGER, + sctsObjectId + Unsigned32, + sctsObjectValue + INTEGER, + sctsObjectDescriptor + DisplayString, + sctsObjectAlarmValue + INTEGER + } + + -- 1.3.6.1.4.1.3715.17.2.5.1.1 + sctsTransportStreamId OBJECT-TYPE + SYNTAX INTEGER (1..8192) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Unique transport stream id inside the interface." + ::= { statusCodeTransportStreamEntry 1 } + + + -- 1.3.6.1.4.1.3715.17.2.5.1.2 + sctsObjectId OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Unique identifier of the monitorable object." + ::= { statusCodeTransportStreamEntry 2 } + + + -- 1.3.6.1.4.1.3715.17.2.5.1.3 + sctsObjectValue OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Value of the monitorable object. + The sctsObjectDescriptor tells name, scale and unit of the object." + ::= { statusCodeTransportStreamEntry 3 } + + -- 1.3.6.1.4.1.3715.17.2.5.1.4 + sctsObjectDescriptor OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Description of the monitorable object. + See dmObjectDescriptor for format, example and usage. + + " + ::= { statusCodeTransportStreamEntry 4 } + + + -- 1.3.6.1.4.1.3715.17.2.5.1.5 + sctsObjectAlarmValue OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "See scdObjectAlarmValue for format, example and usage. + + " + ::= { statusCodeTransportStreamEntry 5 } + + -- 1.3.6.1.4.1.3715.17.2.6 + statusCodeServiceTable OBJECT-TYPE + SYNTAX SEQUENCE OF StatusCodeServiceEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table describes monitorable objects of each service. + The objects may represents real objects or classes. + The monitoring system or user shall not poll this table to detect device state. + + Instead - user shall wait for traps or poll currentAlarmTable(1.3.6.1.4.1.5591.1.1.2) from SCTE-HMS-PROPERTY-MIB. + In this case statusCodeServiceTable shall be used to obtains text definition of alarm." + ::= { statusCode 6 } + + -- 1.3.6.1.4.1.3715.17.2.6.1 + statusCodeServiceEntry OBJECT-TYPE + SYNTAX StatusCodeServiceEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " " + INDEX { interfaceTypeId, scmModuleId, sciInterfaceId, sctsTransportStreamId, scsSID, + scsObjectId } + ::= { statusCodeServiceTable 1 } + + + StatusCodeServiceEntry ::= + SEQUENCE { + scsSID + INTEGER, + scsObjectId + Unsigned32, + scsObjectValue + INTEGER, + scsObjectDescriptor + DisplayString, + scsServiceName + DisplayString, + scsObjectAlarmValue + INTEGER + } + + -- 1.3.6.1.4.1.3715.17.2.6.1.1 + scsSID OBJECT-TYPE + SYNTAX INTEGER (0..65535) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Unique service id number inside the transport stream." + ::= { statusCodeServiceEntry 1 } + + -- 1.3.6.1.4.1.3715.17.2.6.1.2 + scsObjectId OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Unique identifier of the monitorable object." + ::= { statusCodeServiceEntry 2 } + + + -- 1.3.6.1.4.1.3715.17.2.6.1.3 + scsObjectValue OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Value of the monitorable object. + The scsObjectDescriptor tells name, scale and unit of the object." + ::= { statusCodeServiceEntry 3 } + + -- 1.3.6.1.4.1.3715.17.2.6.1.4 + scsObjectDescriptor OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Description of the monitorable object. + See scdObjectDescriptor for format, example and usage. + + " + ::= { statusCodeServiceEntry 4 } + + + -- 1.3.6.1.4.1.3715.17.2.6.1.5 + scsServiceName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The name of the service." + ::= { statusCodeServiceEntry 5 } + + + -- 1.3.6.1.4.1.3715.17.2.6.1.6 + scsObjectAlarmValue OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "See scdObjectAlarmValue for format, example and usage. + + " + ::= { statusCodeServiceEntry 6 } + + + -- 1.3.6.1.4.1.3715.17.2.7 + statusCodePidTable OBJECT-TYPE + SYNTAX SEQUENCE OF StatusCodePidEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table lists monitorable objects of each PID. + The objects may represents real objects or classes. + The monitoring system or user shall not poll this table to detect device state. + + Instead - user shall wait for traps or poll currentAlarmTable(1.3.6.1.4.1.5591.1.1.2) from SCTE-HMS-PROPERTY-MIB. + In this case statusCodePidTable shall be used to obtains text definition of alarm." + ::= { statusCode 7 } + + -- 1.3.6.1.4.1.3715.17.2.7.1 + statusCodePidEntry OBJECT-TYPE + SYNTAX StatusCodePidEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " " + INDEX { interfaceTypeId, scmModuleId, sciInterfaceId, sctsTransportStreamId, scpPID, + scpObjectId } + ::= { statusCodePidTable 1 } + + + StatusCodePidEntry ::= + SEQUENCE { + scpPID + INTEGER, + scpObjectId + Unsigned32, + scpObjectValue + INTEGER, + scpObjectDescriptor + DisplayString, + scpObjectAlarmValue + INTEGER + } + + + -- 1.3.6.1.4.1.3715.17.2.7.1.1 + scpPID OBJECT-TYPE + SYNTAX INTEGER (0..8191) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Unique PID value inside the transport stream." + ::= { statusCodePidEntry 1 } + + + -- 1.3.6.1.4.1.3715.17.2.7.1.2 + scpObjectId OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Unique identifier of the monitorable object." + ::= { statusCodePidEntry 2 } + + + -- 1.3.6.1.4.1.3715.17.2.7.1.3 + scpObjectValue OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Value of the monitorable object. + The scpObjectDescriptor tells name, scale and unit of the object." + ::= { statusCodePidEntry 3 } + + -- 1.3.6.1.4.1.3715.17.2.7.1.4 + scpObjectDescriptor OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Description of the monitorable object. + See scdObjectDescriptor for format, example and usage. + + " + ::= { statusCodePidEntry 4 } + + + -- 1.3.6.1.4.1.3715.17.2.7.1.5 + scpObjectAlarmValue OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "See scdObjectAlarmValue for format, example and usage. + + " + ::= { statusCodePidEntry 5 } + + + -- 1.3.6.1.4.1.3715.17.3 + interface OBJECT IDENTIFIER ::= { luminato 3 } + + -- 1.3.6.1.4.1.3715.17.3.1 + ifExtTable OBJECT-TYPE + SYNTAX SEQUENCE OF IfExtEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "" + ::= { interface 1 } + + + -- 1.3.6.1.4.1.3715.17.3.1.1 + ifExtEntry OBJECT-TYPE + SYNTAX IfExtEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "" + INDEX { INTEGER } + ::= { ifExtTable 1 } + + + IfExtEntry ::= + SEQUENCE { + ifExtIndex + INTEGER, + ifExtName + DisplayString, + ifExtModule + INTEGER, + ifExtPhysInterface + INTEGER, + ifExtLogiInterface + INTEGER, + ifExtDirection + INTEGER + } + + -- 1.3.6.1.4.1.3715.17.3.1.1.1 + ifExtIndex OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A unique index for an interface. + The index is of following format: SDPPVVVV, where: + - S = Slot number + - D = input(1) / output(2) + - PP = Physical interface number + - VVVV = Virtual interface number" + ::= { ifExtEntry 1 } + + + -- 1.3.6.1.4.1.3715.17.3.1.1.2 + ifExtName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Description for the interface." + ::= { ifExtEntry 2 } + + + -- 1.3.6.1.4.1.3715.17.3.1.1.3 + ifExtModule OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of the physical module or slot housing the interface." + ::= { ifExtEntry 3 } + + + -- 1.3.6.1.4.1.3715.17.3.1.1.4 + ifExtPhysInterface OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Physical interface number." + ::= { ifExtEntry 4 } + + + -- 1.3.6.1.4.1.3715.17.3.1.1.5 + ifExtLogiInterface OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Logical interface number." + ::= { ifExtEntry 5 } + + + -- 1.3.6.1.4.1.3715.17.3.1.1.6 + ifExtDirection OBJECT-TYPE + SYNTAX INTEGER + { + input(1), + output(2), + both(3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Direction for the data going through the interface." + ::= { ifExtEntry 6 } + + +-- Signal physical level + + -- 1.3.6.1.4.1.3715.17.3.2 + signalPhysTable OBJECT-TYPE + SYNTAX SEQUENCE OF SignalPhysEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "" + ::= { interface 2 } + + + -- 1.3.6.1.4.1.3715.17.3.2.1 + signalPhysEntry OBJECT-TYPE + SYNTAX SignalPhysEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "" + INDEX { ifExtIndex } + ::= { signalPhysTable 1 } + + + SignalPhysEntry ::= + SEQUENCE { + signalSnr + INTEGER, + signalSnrMin + INTEGER, + signalSnrMax + INTEGER, + signalCcErrors + INTEGER, + signalBer + Float, + signalVber + Float + } + + -- 1.3.6.1.4.1.3715.17.3.2.1.2 + signalSnr OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Recent signal to noise ratio in 1/10th of dB." + ::= { signalPhysEntry 2 } + + + -- 1.3.6.1.4.1.3715.17.3.2.1.3 + signalSnrMin OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Lowest measured SNR value since last device startup or last counter reset." + ::= { signalPhysEntry 3 } + + + -- 1.3.6.1.4.1.3715.17.3.2.1.4 + signalSnrMax OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Highest measured SNR value since last device startup or last counter reset." + ::= { signalPhysEntry 4 } + + + -- 1.3.6.1.4.1.3715.17.3.2.1.5 + signalCcErrors OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The number of continuity errors since last device startup or last counter reset." + ::= { signalPhysEntry 5 } + + + -- 1.3.6.1.4.1.3715.17.3.2.1.6 + signalBer OBJECT-TYPE + SYNTAX Float + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Calculated bit error ratio of the signal." + ::= { signalPhysEntry 6 } + + + -- 1.3.6.1.4.1.3715.17.3.2.1.7 + signalVber OBJECT-TYPE + SYNTAX Float + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Calculated Viterbi bit error ratio of the signal." + ::= { signalPhysEntry 7 } + + + +-- transfer statistics + + -- 1.3.6.1.4.1.3715.17.3.3 + transferTable OBJECT-TYPE + SYNTAX SEQUENCE OF TransferEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "" + ::= { interface 3 } + + + -- 1.3.6.1.4.1.3715.17.3.3.1 + transferEntry OBJECT-TYPE + SYNTAX TransferEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "" + INDEX { ifExtIndex } + ::= { transferTable 1 } + + + TransferEntry ::= + SEQUENCE { + transBitrate + INTEGER, + transBitrateMin + INTEGER, + transBitrateMax + INTEGER + } + + -- 1.3.6.1.4.1.3715.17.3.3.1.2 + transBitrate OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Recent measured bitrate of the interface in kilobits per second." + ::= { transferEntry 2 } + + + -- 1.3.6.1.4.1.3715.17.3.3.1.3 + transBitrateMin OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Lowest measured bitrate since last device startup or last counter reset. + Writing clears the counter." + ::= { transferEntry 3 } + + + -- 1.3.6.1.4.1.3715.17.3.3.1.4 + transBitrateMax OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Highest measured bitrate since last device startup or last counter reset. + Writing clears the counter." + ::= { transferEntry 4 } + + +-- ProMpegFec interface related data + + -- 1.3.6.1.4.1.3715.17.3.20 + proMpegFecTable OBJECT-TYPE + SYNTAX SEQUENCE OF ProMpegFecEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "" + ::= { interface 20 } + + + -- 1.3.6.1.4.1.3715.17.3.20.1 + proMpegFecEntry OBJECT-TYPE + SYNTAX ProMpegFecEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "" + INDEX { ifExtIndex } + ::= { proMpegFecTable 1 } + + + ProMpegFecEntry ::= + SEQUENCE { + fecValidPkts + Counter32, + fecUncorrectedPkts + Counter32, + fecCorrectedPkts + Counter32, + fecDuplicatePkts + Counter32, + fecReorderedPkts + Counter32, + fecIncorrectSeqNumbers + Counter32, + fecDiscontinuities + Counter32 + } + + -- 1.3.6.1.4.1.3715.17.3.20.1.1 + fecValidPkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Number of media stream packets received. + Writing any value in this oid will clear all ProMpegFec related counters on + the current interface." + ::= { proMpegFecEntry 1 } + + + -- 1.3.6.1.4.1.3715.17.3.20.1.2 + fecUncorrectedPkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Number of missing media stream packets after FEC decoding. + Writing any value in this oid will clear all ProMpegFec related counters on + the current interface." + ::= { proMpegFecEntry 2 } + + + -- 1.3.6.1.4.1.3715.17.3.20.1.3 + fecCorrectedPkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Number of corrected packets after FEC decoding. + Writing any value in this oid will clear all ProMpegFec related counters on + the current interface." + ::= { proMpegFecEntry 3 } + + + -- 1.3.6.1.4.1.3715.17.3.20.1.4 + fecDuplicatePkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Number of duplicate packets received. Defined as a received packet with + the same RTP sequence number as any of the packets already in the decoding + buffer. All duplicate packets are automatically discarded and do not cause + missing packets or duplicates to the output stream. + Writing any value in this oid will clear all ProMpegFec related counters on + the current interface." + ::= { proMpegFecEntry 4 } + + + -- 1.3.6.1.4.1.3715.17.3.20.1.5 + fecReorderedPkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Number of reordered packets received. Defined as a received packet which + RTP sequence number is smaller than the highest RTP sequence number already + received, excluding duplicate packets and packets which are out of the + decoding buffer range. These packets will be re-ordered and do not cause + missing packets to the output stream. + Writing any value in this oid will clear all ProMpegFec related counters on + the current interface." + ::= { proMpegFecEntry 5 } + + + -- 1.3.6.1.4.1.3715.17.3.20.1.6 + fecIncorrectSeqNumbers OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Number of received media packets that have RTP sequence number out of + decoding buffer range. All these packet are discarded. If 10 consecutive + packets are out of range then decoding buffer is flushed and re-initialised + i.e. all packets in the buffer are discarded. Incorrect sequence numbers + counter will not be incremented if decoding buffer has been flushed. + Writing any value in this oid will clear all ProMpegFec related counters on + the current interface." + ::= { proMpegFecEntry 6 } + + + -- 1.3.6.1.4.1.3715.17.3.20.1.7 + fecDiscontinuities OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Number of RTP sequence number discontinuities after FEC decoding. Discontinuity + is detected when the sequence number of received RTP packet (after decoding) is + not equal to sequence number of previous packet. Discontinuities are typically + detected when there are uncorrected packets in the stream, or when there are + brief interruptions in the stream (in range of about 1-20 seconds). Also abrupt + change of stream source will be counted as discontinuity because of jump in RTP + sequence numbers. + Writing any value in this oid will clear all ProMpegFec related counters on + the current interface." + ::= { proMpegFecEntry 7 } + + +-- Input service information + -- 1.3.6.1.4.1.3715.17.3.4 + inputServiceTable OBJECT-TYPE + SYNTAX SEQUENCE OF InputServiceEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "" + ::= { interface 4 } + + + -- 1.3.6.1.4.1.3715.17.3.4.1 + inputServiceEntry OBJECT-TYPE + SYNTAX InputServiceEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "" + INDEX { ifExtIndex } + ::= { inputServiceTable 1 } + + + InputServiceEntry ::= + SEQUENCE { + iSID + INTEGER, + iServiceName + DisplayString, + iServiceBitrate + INTEGER + } + + -- 1.3.6.1.4.1.3715.17.3.4.1.2 + iSID OBJECT-TYPE + SYNTAX INTEGER (0..65535) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Unique service id number inside the transport stream." + ::= { inputServiceEntry 2 } + + -- 1.3.6.1.4.1.3715.17.3.4.1.3 + iServiceName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The name of the service." + ::= { inputServiceEntry 3 } + + + -- 1.3.6.1.4.1.3715.17.3.4.1.4 + iServiceBitrate OBJECT-TYPE + SYNTAX INTEGER (0..65535) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The bitrate of service" + ::= { inputServiceEntry 4 } + + -- Output service information + + -- 1.3.6.1.4.1.3715.17.3.5 + outputServiceTable OBJECT-TYPE + SYNTAX SEQUENCE OF OutputServiceEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "" + ::= { interface 5 } + + + -- 1.3.6.1.4.1.3715.17.3.5.1 + outputServiceEntry OBJECT-TYPE + SYNTAX OutputServiceEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "" + INDEX { ifExtIndex } + ::= { outputServiceTable 1 } + + + OutputServiceEntry ::= + SEQUENCE { + oSID + INTEGER, + oServiceName + DisplayString, + oServiceBitrate + INTEGER + } + + -- 1.3.6.1.4.1.3715.17.3.5.1.2 + oSID OBJECT-TYPE + SYNTAX INTEGER (0..65535) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Unique service id number inside the transport stream." + ::= { outputServiceEntry 2 } + + -- 1.3.6.1.4.1.3715.17.3.5.1.2 + oServiceName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The name of the service." + ::= { outputServiceEntry 3 } + + + -- 1.3.6.1.4.1.3715.17.3.5.1.3 + oServiceBitrate OBJECT-TYPE + SYNTAX INTEGER (0..65535) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The bitrate of service" + ::= { outputServiceEntry 4 } +---------------------------------------------------------------------- + + -- 1.3.6.1.4.1.3715.17.4 + notifications OBJECT IDENTIFIER ::= { luminato 4 } + + + -- 1.3.6.1.4.1.3715.17.5 + statusFlags OBJECT IDENTIFIER ::= { luminato 5 } + + + -- 1.3.6.1.4.1.3715.17.5.2 + moduleStatusTable OBJECT-TYPE + SYNTAX SEQUENCE OF ModuleStatusEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION " " + ::= { statusFlags 2 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1 + moduleStatusEntry OBJECT-TYPE + SYNTAX ModuleStatusEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION " " + INDEX { moduleId } + ::= { moduleStatusTable 1 } + + + ModuleStatusEntry ::= + SEQUENCE { + moduleId + INTEGER, + modulePidConflictStatus + INTEGER, + moduleTemperatureHigh + INTEGER, + moduleTemperatureLow + INTEGER, + modulePidCapaStatus + INTEGER, + modulePsisiCaptureCapaStatus + INTEGER, + moduleSidAllocStatus + INTEGER, + moduleCaDetectStatus + INTEGER, + moduleDetectStatus + INTEGER, + moduleVoltageHigh + INTEGER, + moduleVoltageLow + INTEGER, + moduleCurrentHigh + INTEGER, + moduleCurrentLow + INTEGER, + moduleDaemonInitStatus + INTEGER, + moduleDriverStatus + INTEGER, + moduleHwStatus + INTEGER, + moduleFanStatus + INTEGER, + modulePowerSourceStatus + INTEGER, + modulePsuOverloadStatus + INTEGER, + moduleBootupProgressStatus + INTEGER, + moduleBootupRetryStatus + INTEGER, + moduleBootupStatus + INTEGER, + moduleShutdownProgressStatus + INTEGER, + moduleConnStatus + INTEGER, + moduleCompatStatus + INTEGER, + moduleUpcPowerLow + INTEGER, + moduleUpcPowerHigh + INTEGER, + moduleCalibrDataStatus + INTEGER, + moduleCalibrDataCheckStatus + INTEGER, + moduleDescrStatus + INTEGER, + moduleBackupStatus + INTEGER, + moduleNitOutputsStatus + INTEGER, + moduleNitSelectionStatus + INTEGER, + moduleNitConfChangeStatus + INTEGER, + moduleNitDataQueryStatus + INTEGER, + moduleNitWizardStatus + INTEGER, + moduleQamFreqStatus + INTEGER, + moduleOutputSidStatus + INTEGER, + moduleConfStatus + INTEGER, + moduleFreqStatus + INTEGER, + moduleOutputPowerStatus + INTEGER, + moduleSymrateStatus + INTEGER, + moduleChanDistStatus + INTEGER, + moduleLnbVoltStatus + INTEGER, + moduleFecRateStatus + INTEGER, + moduleLnbCurrStatus + INTEGER, + moduleFreqOffsetStatus + INTEGER, + moduleDescrRestartStatus + INTEGER, + moduleCamRestartStatus + INTEGER, + moduleEcmgStatus + INTEGER, + moduleEcmStreamStatus + INTEGER, + moduleEmmStatus + INTEGER, + moduleEmmStreamStatus + INTEGER, + moduleEcmgConnStatus + INTEGER, + moduleEmmConnStatus + INTEGER, + moduleEcmgSpareStatus + INTEGER, + moduleBootloaderAvailStatus + INTEGER, + moduleBl1UpdateProgStatus + INTEGER, + moduleBl2UpdateProgStatus + INTEGER, + moduleBl1UpdateStatus + INTEGER, + moduleBl2UpdateStatus + INTEGER, + moduleActiveBackupStatus + INTEGER, + moduleConfProgressStatus + INTEGER, + modulePresenceStatus + INTEGER, + moduleProcessRestartStatus + INTEGER, + moduleBackupLicenseStatus + INTEGER, + modulePsisiEditorLicenseStatus + INTEGER, + moduleMuxLicenseStatus + INTEGER, + moduleDemuxLicenseStatus + INTEGER, + moduleDvbLicenseStatus + INTEGER, + moduleMsdLicenseStatus + INTEGER, + moduleDvbs2LicenseStatus + INTEGER, + moduleDvbt2LicenseStatus + INTEGER, + moduleScsLicenseStatus + INTEGER, + moduleCliLoginStatus + INTEGER, + moduleRedunActivationStatus + INTEGER, + moduleExtioPinSignalingStatus + INTEGER, + moduleBackupPsuStatus + INTEGER, + moduleIntrusionStatus + INTEGER, + moduleRedunStatus + INTEGER, + moduleBackupHwStatus + INTEGER, + moduleSwUpdateProgress + INTEGER, + moduleSwUpdateStatus + INTEGER, + moduleEitLicenseStatus + INTEGER, + moduleDescramblingStatus + INTEGER, + moduleDvbTimeStatus + INTEGER, + moduleTunerDcFeedStatus + INTEGER, + moduleTunerPlpSelectionReqStatus + INTEGER, + moduleTunerPlpStatus + INTEGER, + moduleTunerHierarchyStatus + INTEGER, + moduleEcmStatus + INTEGER, + moduleScramConflictStatus + INTEGER, + moduleScramSharedStatus + INTEGER, + moduleBackupVoltageHigh + INTEGER, + moduleBackupVoltageLow + INTEGER, + moduleSdtTableStatus + INTEGER, + moduleDescramblingRestart + INTEGER, + moduleCaModuleRestart + INTEGER, + moduleCaMenuStatus + INTEGER, + moduleInvalidCamRouting + INTEGER, + moduleNitSidConflict + INTEGER, + moduleLicenseMissingFEC + INTEGER, + moduleFecCorrectionStatus + INTEGER, + moduleFecPacketDropStatus + INTEGER, + moduleFecMediaPktsStatus + INTEGER, + moduleSfpLinkStatus + INTEGER, + moduleBackupSyncModeOff + INTEGER, + moduleBackupSyncModeManual + INTEGER, + moduleBackupSyncModeAuto + INTEGER, + moduleBackupSyncConfStatus + INTEGER, + moduleBackupSyncStatus + INTEGER, + moduleBackupSyncSwCompatibility + INTEGER, + moduleBackupSyncHwCompatibility + INTEGER, + moduleBackupSyncConfFaultStatus + INTEGER, + moduleBackupSyncConnectionStatus + INTEGER, + moduleBackupSyncFromBackupStatus + INTEGER, + moduleBackupSyncRebootStatus + INTEGER, + moduleBackupSyncLicenseCompatStatus + INTEGER, + moduleBackupSyncLicenseCompareStatus + INTEGER, + moduleDeviceFirstBootStatus + INTEGER, + modulePartitionConfigurationBackup + INTEGER, + modulePartitionConfigurationRestore + INTEGER, + moduleSwRevertStatus + INTEGER, + moduleMaxOutputPidsStatus + INTEGER, + moduleUserRebootStatus + INTEGER, + moduleRemovalStatus + INTEGER, + moduleInsertionStatus + INTEGER, + moduleSptsInputConfStatus + INTEGER + } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.1 + moduleId OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Module identifier" + ::= { moduleStatusEntry 1 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4 + modulePidConflictStatus OBJECT-TYPE + SYNTAX INTEGER + { + pidOk(1), + pidConflict(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "PID conflict status" + ::= { moduleStatusEntry 4 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.6 + moduleTemperatureHigh OBJECT-TYPE + SYNTAX INTEGER + { + temperatureNominal(1), + temperatureHigh(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "High temperature status" + ::= { moduleStatusEntry 6 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.7 + moduleTemperatureLow OBJECT-TYPE + SYNTAX INTEGER + { + temperatureNominal(1), + temperatureLow(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Low temperature status" + ::= { moduleStatusEntry 7 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4104 + modulePidCapaStatus OBJECT-TYPE + SYNTAX INTEGER + { + capacityNominal(1), + capacityExceeded(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Module PID capacity status" + ::= { moduleStatusEntry 4104 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4105 + modulePsisiCaptureCapaStatus OBJECT-TYPE + SYNTAX INTEGER + { + capacityNominal(1), + capacityExceeded(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Module PSI/SI table capture capacity status" + ::= { moduleStatusEntry 4105 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4106 + moduleSidAllocStatus OBJECT-TYPE + SYNTAX INTEGER + { + sidAllocOk(1), + sidAllocCapaExceeded(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Module service ID allocation capacity status" + ::= { moduleStatusEntry 4106 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4108 + moduleCaDetectStatus OBJECT-TYPE + SYNTAX INTEGER + { + moduleOk(1), + moduleMissing(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "CA module detection status" + ::= { moduleStatusEntry 4108 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4111 + moduleDetectStatus OBJECT-TYPE + SYNTAX INTEGER + { + moduleOk(1), + moduleUnknown(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Module detection status" + ::= { moduleStatusEntry 4111 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4112 + moduleVoltageHigh OBJECT-TYPE + SYNTAX INTEGER + { + voltageNominal(1), + voltageHigh(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "High voltage status" + ::= { moduleStatusEntry 4112 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4113 + moduleVoltageLow OBJECT-TYPE + SYNTAX INTEGER + { + voltageNominal(1), + voltageLow(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Low voltage status" + ::= { moduleStatusEntry 4113 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4114 + moduleCurrentHigh OBJECT-TYPE + SYNTAX INTEGER + { + currentNominal(1), + currentHigh(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "High current status" + ::= { moduleStatusEntry 4114 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4115 + moduleCurrentLow OBJECT-TYPE + SYNTAX INTEGER + { + currentNominal(1), + currentLow(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Low current status" + ::= { moduleStatusEntry 4115 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4127 + moduleDaemonInitStatus OBJECT-TYPE + SYNTAX INTEGER + { + daemonNominal(1), + daemonInitFailed(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Module daemon initialization status" + ::= { moduleStatusEntry 4127 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4129 + moduleDriverStatus OBJECT-TYPE + SYNTAX INTEGER + { + driverNominal(1), + driverFailure(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Module device driver status" + ::= { moduleStatusEntry 4129 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4130 + moduleHwStatus OBJECT-TYPE + SYNTAX INTEGER + { + hwNominal(1), + hwFailure(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Module hardware status" + ::= { moduleStatusEntry 4130 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4131 + moduleFanStatus OBJECT-TYPE + SYNTAX INTEGER + { + fanNominal(1), + fanFailure(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Fan status" + ::= { moduleStatusEntry 4131 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4132 + modulePowerSourceStatus OBJECT-TYPE + SYNTAX INTEGER + { + runningOnMainPower(1), + runningOnBackupPower(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Power source status" + ::= { moduleStatusEntry 4132 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4133 + modulePsuOverloadStatus OBJECT-TYPE + SYNTAX INTEGER + { + psuNominal(1), + psuOverloaded(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Power supply overload status" + ::= { moduleStatusEntry 4133 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4134 + moduleBootupProgressStatus OBJECT-TYPE + SYNTAX INTEGER + { + moduleNominal(1), + moduleBootingUp(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Module bootup progress" + ::= { moduleStatusEntry 4134 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4135 + moduleBootupRetryStatus OBJECT-TYPE + SYNTAX INTEGER + { + moduleNominal(1), + moduleBootingRetrying(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Module bootup retry status" + ::= { moduleStatusEntry 4135 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4136 + moduleBootupStatus OBJECT-TYPE + SYNTAX INTEGER + { + moduleNominal(1), + moduleBootFailure(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Module bootup status" + ::= { moduleStatusEntry 4136 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4137 + moduleShutdownProgressStatus OBJECT-TYPE + SYNTAX INTEGER + { + moduleNominal(1), + moduleShuttingDown(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Module shutdown progress" + ::= { moduleStatusEntry 4137 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4138 + moduleConnStatus OBJECT-TYPE + SYNTAX INTEGER + { + connectionNominal(1), + connectionLost(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Module connection status" + ::= { moduleStatusEntry 4138 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4139 + moduleCompatStatus OBJECT-TYPE + SYNTAX INTEGER + { + moduleNominal(1), + moduleIncompatible(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Module compatibility status" + ::= { moduleStatusEntry 4139 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4147 + moduleUpcPowerLow OBJECT-TYPE + SYNTAX INTEGER + { + ucpPowerNominal(1), + ucpPowerLow(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Module UPC input power low status" + ::= { moduleStatusEntry 4147 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4148 + moduleUpcPowerHigh OBJECT-TYPE + SYNTAX INTEGER + { + ucpPowerNominal(1), + ucpPowerHigh(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Module UPC input power high status" + ::= { moduleStatusEntry 4148 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4149 + moduleCalibrDataStatus OBJECT-TYPE + SYNTAX INTEGER + { + calibrationDataNominal(1), + calibrationDataMissing(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Module calibration data status" + ::= { moduleStatusEntry 4149 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4150 + moduleCalibrDataCheckStatus OBJECT-TYPE + SYNTAX INTEGER + { + checkOk(1), + checkSkipped(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Module calibration data check status" + ::= { moduleStatusEntry 4150 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4151 + moduleDescrStatus OBJECT-TYPE + SYNTAX INTEGER + { + descramblingOk(1), + descramblingFailure(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Module descrambling status" + ::= { moduleStatusEntry 4151 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4153 + moduleBackupStatus OBJECT-TYPE + SYNTAX INTEGER + { + moduleNominal(1), + moduleSwitchedToBackup(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Module backup status" + ::= { moduleStatusEntry 4153 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4154 + moduleNitOutputsStatus OBJECT-TYPE + SYNTAX INTEGER + { + nitOutputsNominal(1), + noSupportedNitOutputs(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Supported Nit output module status" + ::= { moduleStatusEntry 4154 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4155 + moduleNitSelectionStatus OBJECT-TYPE + SYNTAX INTEGER + { + nitSelectionNominal(1), + noSelectedNitOutputs(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Nit output selection status" + ::= { moduleStatusEntry 4155 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4156 + moduleNitConfChangeStatus OBJECT-TYPE + SYNTAX INTEGER + { + nitConfNominal(1), + nitConfChanged(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Nit configuration change status" + ::= { moduleStatusEntry 4156 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4157 + moduleNitDataQueryStatus OBJECT-TYPE + SYNTAX INTEGER + { + nitDataQueryNominal(1), + nitDataQueryFailure(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Nit data query status" + ::= { moduleStatusEntry 4157 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4158 + moduleNitWizardStatus OBJECT-TYPE + SYNTAX INTEGER + { + nitWizardNominal(1), + nitWizardFailure(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Nit wizard status" + ::= { moduleStatusEntry 4158 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4159 + moduleQamFreqStatus OBJECT-TYPE + SYNTAX INTEGER + { + qamFreqUnique(1), + qamFreqDuplicate(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "QAM output unique frequency status" + ::= { moduleStatusEntry 4159 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4173 + moduleOutputSidStatus OBJECT-TYPE + SYNTAX INTEGER + { + sidOk(1), + sidConflict(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Module output SID status" + ::= { moduleStatusEntry 4173 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4175 + moduleConfStatus OBJECT-TYPE + SYNTAX INTEGER + { + configurationOk(1), + configurationUnsupported(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Module configuration status" + ::= { moduleStatusEntry 4175 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4176 + moduleFreqStatus OBJECT-TYPE + SYNTAX INTEGER + { + freqOk(1), + freqOutOfRange(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Module frequency configuration range status" + ::= { moduleStatusEntry 4176 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4177 + moduleOutputPowerStatus OBJECT-TYPE + SYNTAX INTEGER + { + powerOk(1), + powerOutOfRange(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Module output power status" + ::= { moduleStatusEntry 4177 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4178 + moduleSymrateStatus OBJECT-TYPE + SYNTAX INTEGER + { + symbolRateOk(1), + symbolRateOutOfRange(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Module symbol rate configuration status" + ::= { moduleStatusEntry 4178 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4179 + moduleChanDistStatus OBJECT-TYPE + SYNTAX INTEGER + { + chanDistOk(1), + chanDistTooNarrow(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Module channel distance configuration status" + ::= { moduleStatusEntry 4179 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4180 + moduleLnbVoltStatus OBJECT-TYPE + SYNTAX INTEGER + { + lnbVoltageOk(1), + lnbVoltageInvalid(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Module LNB voltage configuration status" + ::= { moduleStatusEntry 4180 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4181 + moduleFecRateStatus OBJECT-TYPE + SYNTAX INTEGER + { + fecRateOk(1), + fecRateInvalid(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Module FEC rate configuration vs modulation status" + ::= { moduleStatusEntry 4181 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4182 + moduleLnbCurrStatus OBJECT-TYPE + SYNTAX INTEGER + { + lnbCurrentOk(1), + lnbCurrentInvalid(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Module LNB current status" + ::= { moduleStatusEntry 4182 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4183 + moduleFreqOffsetStatus OBJECT-TYPE + SYNTAX INTEGER + { + freqOffsetOk(1), + freqOffsetInvalid(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Module frequency offset configuration status" + ::= { moduleStatusEntry 4183 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4185 + moduleDescrRestartStatus OBJECT-TYPE + SYNTAX INTEGER + { + descramblingNominal(1), + descramblingRestarting(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Module descrambling restart status" + ::= { moduleStatusEntry 4185 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4186 + moduleCamRestartStatus OBJECT-TYPE + SYNTAX INTEGER + { + camNominal(1), + camRestarting(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Module CAM restart status" + ::= { moduleStatusEntry 4186 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4187 + moduleEcmgStatus OBJECT-TYPE + SYNTAX INTEGER + { + ecmgNominal(1), + ecmgFailure(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Ecmg status" + ::= { moduleStatusEntry 4187 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4188 + moduleEcmStreamStatus OBJECT-TYPE + SYNTAX INTEGER + { + ecmStreamNominal(1), + ecmStreamFailure(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Ecm stream status" + ::= { moduleStatusEntry 4188 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4189 + moduleEmmStatus OBJECT-TYPE + SYNTAX INTEGER + { + emmNominal(1), + emmFailure(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Emm status" + ::= { moduleStatusEntry 4189 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4190 + moduleEmmStreamStatus OBJECT-TYPE + SYNTAX INTEGER + { + emmStreamNominal(1), + emmStreamFailure(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Emm stream status" + ::= { moduleStatusEntry 4190 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4191 + moduleEcmgConnStatus OBJECT-TYPE + SYNTAX INTEGER + { + ecmgConnNominal(1), + ecmgNotConnected(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Ecmg connection status" + ::= { moduleStatusEntry 4191 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4192 + moduleEmmConnStatus OBJECT-TYPE + SYNTAX INTEGER + { + emmConnNominal(1), + emmNotConnected(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Emm connection status" + ::= { moduleStatusEntry 4192 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4194 + moduleEcmgSpareStatus OBJECT-TYPE + SYNTAX INTEGER + { + ecmgNominal(1), + ecmgSwitchedToSpare(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Ecmg spare connection status" + ::= { moduleStatusEntry 4194 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4195 + moduleBootloaderAvailStatus OBJECT-TYPE + SYNTAX INTEGER + { + bootloaderOk(1), + bootloaderObsolete(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Module bootloader availability status" + ::= { moduleStatusEntry 4195 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4196 + moduleBl1UpdateProgStatus OBJECT-TYPE + SYNTAX INTEGER + { + bootloaderNominal(1), + bootloaderUpdating(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Module bootloader update progress" + ::= { moduleStatusEntry 4196 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4197 + moduleBl2UpdateProgStatus OBJECT-TYPE + SYNTAX INTEGER + { + bootloaderNominal(1), + bootloaderUpdating(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Module bootloader update progress" + ::= { moduleStatusEntry 4197 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4198 + moduleBl1UpdateStatus OBJECT-TYPE + SYNTAX INTEGER + { + bootloaderNominal(1), + bootloaderUpdateFailure(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Module bootloader update status" + ::= { moduleStatusEntry 4198 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4199 + moduleBl2UpdateStatus OBJECT-TYPE + SYNTAX INTEGER + { + bootloaderNominal(1), + bootloaderUpdateFailure(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Module bootloader update status" + ::= { moduleStatusEntry 4199 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4203 + moduleActiveBackupStatus OBJECT-TYPE + SYNTAX INTEGER + { + backupPassive(1), + backupActive(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Backup module status" + ::= { moduleStatusEntry 4203 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4205 + moduleConfProgressStatus OBJECT-TYPE + SYNTAX INTEGER + { + moduleNominal(1), + moduleConfiguring(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Module configuration progress" + ::= { moduleStatusEntry 4205 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4206 + modulePresenceStatus OBJECT-TYPE + SYNTAX INTEGER + { + moduleNominal(1), + noModule(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Module presence progress" + ::= { moduleStatusEntry 4206 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4208 + moduleProcessRestartStatus OBJECT-TYPE + SYNTAX INTEGER + { + processesNominal(1), + processRestarted(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Process restart status" + ::= { moduleStatusEntry 4208 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4209 + moduleBackupLicenseStatus OBJECT-TYPE + SYNTAX INTEGER + { + licenseOk(1), + notLicensed(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Backup license status" + ::= { moduleStatusEntry 4209 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4210 + modulePsisiEditorLicenseStatus OBJECT-TYPE + SYNTAX INTEGER + { + licenseOk(1), + notLicensed(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "PSI/SI editor license status" + ::= { moduleStatusEntry 4210 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4211 + moduleMuxLicenseStatus OBJECT-TYPE + SYNTAX INTEGER + { + licenseOk(1), + notLicensed(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Multiplexing license status" + ::= { moduleStatusEntry 4211 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4212 + moduleDemuxLicenseStatus OBJECT-TYPE + SYNTAX INTEGER + { + licenseOk(1), + notLicensed(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Demultiplexing license status" + ::= { moduleStatusEntry 4212 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4213 + moduleDvbLicenseStatus OBJECT-TYPE + SYNTAX INTEGER + { + licenseOk(1), + notLicensed(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "DVB processing license status" + ::= { moduleStatusEntry 4213 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4214 + moduleMsdLicenseStatus OBJECT-TYPE + SYNTAX INTEGER + { + licenseOk(1), + notLicensed(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "MSD license status" + ::= { moduleStatusEntry 4214 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4215 + moduleDvbs2LicenseStatus OBJECT-TYPE + SYNTAX INTEGER + { + licenseOk(1), + notLicensed(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "DVB-S2 processing license status" + ::= { moduleStatusEntry 4215 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4216 + moduleDvbt2LicenseStatus OBJECT-TYPE + SYNTAX INTEGER + { + licenseOk(1), + notLicensed(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "DVB-T2 processing license status" + ::= { moduleStatusEntry 4216 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4217 + moduleScsLicenseStatus OBJECT-TYPE + SYNTAX INTEGER + { + licenseValid(1), + notLicensed(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Scs license status" + ::= { moduleStatusEntry 4217 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4218 + moduleCliLoginStatus OBJECT-TYPE + SYNTAX INTEGER + { + cliNotLoggedIn(1), + cliLoggedIn(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "CLI login status" + ::= { moduleStatusEntry 4218 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4222 + moduleRedunActivationStatus OBJECT-TYPE + SYNTAX INTEGER + { + redundancyPassive(1), + redundancyActivated(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Redundancy activation status" + ::= { moduleStatusEntry 4222 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4223 + moduleExtioPinSignalingStatus OBJECT-TYPE + SYNTAX INTEGER + { + extioPinNominal(1), + extioPinSignaled(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "EXT-IO pin status" + ::= { moduleStatusEntry 4223 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4224 + moduleBackupPsuStatus OBJECT-TYPE + SYNTAX INTEGER + { + backupPsuNominal(1), + backupPsuFailure(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Backup power supply status" + ::= { moduleStatusEntry 4224 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4225 + moduleIntrusionStatus OBJECT-TYPE + SYNTAX INTEGER + { + intrusionNominal(1), + intrusionDetected(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Intrusion detection status" + ::= { moduleStatusEntry 4225 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4227 + moduleRedunStatus OBJECT-TYPE + SYNTAX INTEGER + { + redundancyOk(1), + redundancyFailure(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Redundancy status" + ::= { moduleStatusEntry 4227 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4230 + moduleBackupHwStatus OBJECT-TYPE + SYNTAX INTEGER + { + backupHwOk(1), + backupHwNotSupported(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Hardware backup support status" + ::= { moduleStatusEntry 4230 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4231 + moduleSwUpdateProgress OBJECT-TYPE + SYNTAX INTEGER + { + swUpdateInactive(1), + swUpdateInProgress(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Software update progress" + ::= { moduleStatusEntry 4231 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4233 + moduleSwUpdateStatus OBJECT-TYPE + SYNTAX INTEGER + { + swNominal(1), + swUpdateFailure(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Software update status" + ::= { moduleStatusEntry 4233 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4235 + moduleEitLicenseStatus OBJECT-TYPE + SYNTAX INTEGER + { + licenseValid(1), + notLicensed(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "EIT license status" + ::= { moduleStatusEntry 4235 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4237 + moduleDescramblingStatus OBJECT-TYPE + SYNTAX INTEGER + { + descramblingNominal(1), + descramblingFailure(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Descrambling status" + ::= { moduleStatusEntry 4237 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4243 + moduleDvbTimeStatus OBJECT-TYPE + SYNTAX INTEGER + { + dvbTimeNominal(1), + dvbTimeMissing(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "DVB time detection status" + ::= { moduleStatusEntry 4243 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4245 + moduleTunerDcFeedStatus OBJECT-TYPE + SYNTAX INTEGER + { + currentNominal(1), + currentOutOfRange(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Tuner DC feed current status" + ::= { moduleStatusEntry 4245 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4247 + moduleTunerPlpSelectionReqStatus OBJECT-TYPE + SYNTAX INTEGER + { + plpSelectionOk(1), + plpSelectionRequired(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Tuner data PLP ID requirement status" + ::= { moduleStatusEntry 4247 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4248 + moduleTunerPlpStatus OBJECT-TYPE + SYNTAX INTEGER + { + plpSelectionValid(1), + plpSelectionNotValid(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Tuner data PLP ID validity status" + ::= { moduleStatusEntry 4248 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4249 + moduleTunerHierarchyStatus OBJECT-TYPE + SYNTAX INTEGER + { + hierarchyOk(1), + hierarchyInvalid(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Status of transmission hierarchy" + ::= { moduleStatusEntry 4249 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4250 + moduleEcmStatus OBJECT-TYPE + SYNTAX INTEGER + { + ecmNominal(1), + ecmMissing(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "ECM stream connection status" + ::= { moduleStatusEntry 4250 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4251 + moduleScramConflictStatus OBJECT-TYPE + SYNTAX INTEGER + { + scramblingNominal(1), + scramblingConflict(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Module scrambling shared component conflict status" + ::= { moduleStatusEntry 4251 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4252 + moduleScramSharedStatus OBJECT-TYPE + SYNTAX INTEGER + { + scramblingNominal(1), + scramblingSharedComponent(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Module scrambling shared component status" + ::= { moduleStatusEntry 4252 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4253 + moduleBackupVoltageHigh OBJECT-TYPE + SYNTAX INTEGER + { + voltageNominal(1), + voltageHigh(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Backup high voltage status" + ::= { moduleStatusEntry 4253 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4254 + moduleBackupVoltageLow OBJECT-TYPE + SYNTAX INTEGER + { + voltageNominal(1), + voltageLow(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Backup low voltage status" + ::= { moduleStatusEntry 4254 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4255 + moduleSdtTableStatus OBJECT-TYPE + SYNTAX INTEGER + { + sdtTableOk(1), + invalidSdtTableTemplate(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Sdt table template status" + ::= { moduleStatusEntry 4255 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4256 + moduleDescramblingRestart OBJECT-TYPE + SYNTAX INTEGER + { + descramblingNominal(1), + descramblingRestarting(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Descrambling restart status" + ::= { moduleStatusEntry 4256 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4257 + moduleCaModuleRestart OBJECT-TYPE + SYNTAX INTEGER + { + caModuleNominal(1), + caModuleRestarting(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "CA module restart status" + ::= { moduleStatusEntry 4257 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4258 + moduleCaMenuStatus OBJECT-TYPE + SYNTAX INTEGER + { + caMenuNominal(1), + caMenuOpen(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "CA menu access status" + ::= { moduleStatusEntry 4258 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4259 + moduleInvalidCamRouting OBJECT-TYPE + SYNTAX INTEGER + { + camRoutingNominal(1), + camRoutingInvalid(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "CAM routing status" + ::= { moduleStatusEntry 4259 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4260 + moduleNitSidConflict OBJECT-TYPE + SYNTAX INTEGER + { + nitSidNominal(1), + nitSidConflict(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Nit / Sid conflict status" + ::= { moduleStatusEntry 4260 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4262 + moduleLicenseMissingFEC OBJECT-TYPE + SYNTAX INTEGER + { + licenseOk(1), + licenseMissing(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "FEC license status" + ::= { moduleStatusEntry 4262 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4263 + moduleFecCorrectionStatus OBJECT-TYPE + SYNTAX INTEGER + { + correctionNominal(1), + correctionOverload(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Fec packet correction status. Correction overload (2) is result of too many simultaneous missing packets." + ::= { moduleStatusEntry 4263 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4264 + moduleFecPacketDropStatus OBJECT-TYPE + SYNTAX INTEGER + { + packetsNominal(1), + packetsDropped(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "FEC packet discarding status. Packet discarding (2) is resulted by too high bitrate." + ::= { moduleStatusEntry 4264 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4265 + moduleFecMediaPktsStatus OBJECT-TYPE + SYNTAX INTEGER + { + packetsNominal(1), + packetsDiscarded(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Fec media packet discarding status. Packet discarding (2) is resulted by too high bitrate." + ::= { moduleStatusEntry 4265 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4269 + moduleSfpLinkStatus OBJECT-TYPE + SYNTAX INTEGER + { + sfpLinkNominal(1), + sfpLinkDown(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "SFP link status" + ::= { moduleStatusEntry 4269 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4272 + moduleBackupSyncModeOff OBJECT-TYPE + SYNTAX INTEGER + { + modeNominal(1), + modeOff(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Backup sync mode off status flag" + ::= { moduleStatusEntry 4272 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4273 + moduleBackupSyncModeManual OBJECT-TYPE + SYNTAX INTEGER + { + modeNominal(1), + modeManual(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Backup sync mode manual status flag" + ::= { moduleStatusEntry 4273 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4274 + moduleBackupSyncModeAuto OBJECT-TYPE + SYNTAX INTEGER + { + modeNominal(1), + modeAuto(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Backup sync mode automatic status flag" + ::= { moduleStatusEntry 4274 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4275 + moduleBackupSyncConfStatus OBJECT-TYPE + SYNTAX INTEGER + { + configurationNominal(1), + configurationChanged(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Backup sync configuration change status" + ::= { moduleStatusEntry 4275 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4276 + moduleBackupSyncStatus OBJECT-TYPE + SYNTAX INTEGER + { + syncNominal(1), + synchronizing(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Backup configuration synchronization status" + ::= { moduleStatusEntry 4276 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4278 + moduleBackupSyncSwCompatibility OBJECT-TYPE + SYNTAX INTEGER + { + swCompatible(1), + swIncompatible(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Software version compatibility for backup sync" + ::= { moduleStatusEntry 4278 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4279 + moduleBackupSyncHwCompatibility OBJECT-TYPE + SYNTAX INTEGER + { + hwCompatible(1), + hwIncompatible(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Hardware version compatibility for backup sync" + ::= { moduleStatusEntry 4279 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4280 + moduleBackupSyncConfFaultStatus OBJECT-TYPE + SYNTAX INTEGER + { + configurationNominal(1), + configurationFault(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Backup sync configuration fault status" + ::= { moduleStatusEntry 4280 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4281 + moduleBackupSyncConnectionStatus OBJECT-TYPE + SYNTAX INTEGER + { + connectionNominal(1), + connectionLost(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Backup sync connection status" + ::= { moduleStatusEntry 4281 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4283 + moduleBackupSyncFromBackupStatus OBJECT-TYPE + SYNTAX INTEGER + { + syncNominal(1), + syncNotPossible(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Status flag for backup autosync from backup to main" + ::= { moduleStatusEntry 4283 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4284 + moduleBackupSyncRebootStatus OBJECT-TYPE + SYNTAX INTEGER + { + pairDevNominal(1), + pairDevRebooting(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Status flag for rebooting pair device to new configuration" + ::= { moduleStatusEntry 4284 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4285 + moduleBackupSyncLicenseCompatStatus OBJECT-TYPE + SYNTAX INTEGER + { + licensesCompatible(1), + licensesIncompatible(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "License compatibility status flag for backup sync" + ::= { moduleStatusEntry 4285 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4286 + moduleBackupSyncLicenseCompareStatus OBJECT-TYPE + SYNTAX INTEGER + { + licenseNominal(1), + licenseComparing(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Backup sync license comparing status" + ::= { moduleStatusEntry 4286 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4288 + moduleDeviceFirstBootStatus OBJECT-TYPE + SYNTAX INTEGER + { + firstBootNominal(1), + firstBootInProgress(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Status flag for device first boot operations" + ::= { moduleStatusEntry 4288 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4289 + modulePartitionConfigurationBackup OBJECT-TYPE + SYNTAX INTEGER + { + configurationNominal(1), + configurationBackupInProgress(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Status flag for partition configuration backup operation" + ::= { moduleStatusEntry 4289 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4290 + modulePartitionConfigurationRestore OBJECT-TYPE + SYNTAX INTEGER + { + configurationNominal(1), + configurationRestoreInProgress(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Status flag for partition configuration restore operation" + ::= { moduleStatusEntry 4290 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4291 + moduleSwRevertStatus OBJECT-TYPE + SYNTAX INTEGER + { + swNominal(1), + swRevertInProgress(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Software revertion status" + ::= { moduleStatusEntry 4291 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4292 + moduleMaxOutputPidsStatus OBJECT-TYPE + SYNTAX INTEGER + { + pidsNominal(1), + maxPidsUsed(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Status flag for maximum number of Pid allocations" + ::= { moduleStatusEntry 4292 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4293 + moduleUserRebootStatus OBJECT-TYPE + SYNTAX INTEGER + { + moduleNominal(1), + moduleRebootedByUser(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Status flag for user initiated reboot" + ::= { moduleStatusEntry 4293 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4294 + moduleRemovalStatus OBJECT-TYPE + SYNTAX INTEGER + { + moduleNominal(1), + moduleRemoved(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Status flag for module removal" + ::= { moduleStatusEntry 4294 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4295 + moduleInsertionStatus OBJECT-TYPE + SYNTAX INTEGER + { + moduleNominal(1), + moduleInserted(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Status flag for module insertion" + ::= { moduleStatusEntry 4295 } + + + -- 1.3.6.1.4.1.3715.17.5.2.1.4296 + moduleSptsInputConfStatus OBJECT-TYPE + SYNTAX INTEGER + { + sptsInputNominal(1), + inputNotSpts(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Status flag for input spts misconfiguration" + ::= { moduleStatusEntry 4296 } + + + + -- 1.3.6.1.4.1.3715.17.5.3 + ifStatusTable OBJECT-TYPE + SYNTAX SEQUENCE OF IfStatusEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION " " + ::= { statusFlags 3 } + + + -- 1.3.6.1.4.1.3715.17.5.3.1 + ifStatusEntry OBJECT-TYPE + SYNTAX IfStatusEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION " " + INDEX { moduleId, ifDirection, ifId } + ::= { ifStatusTable 1 } + + + IfStatusEntry ::= + SEQUENCE { + ifId + INTEGER, + ifDirection + INTEGER, + ifSignalStatus + INTEGER, + ifAsiLinkStatus + INTEGER, + ifLinkStatus + INTEGER + } + + -- 1.3.6.1.4.1.3715.17.5.3.1.1 + ifId OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Interface identifier" + ::= { ifStatusEntry 1 } + + + -- 1.3.6.1.4.1.3715.17.5.3.1.2 + ifDirection OBJECT-TYPE + SYNTAX INTEGER + { + input(1), + output(2), + both(3) + } + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Interface data direction" + ::= { ifStatusEntry 2 } + + + -- 1.3.6.1.4.1.3715.17.5.3.1.4097 + ifSignalStatus OBJECT-TYPE + SYNTAX INTEGER + { + signalOk(1), + signalMissing(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Interface signal status" + ::= { ifStatusEntry 4097 } + + + -- 1.3.6.1.4.1.3715.17.5.3.1.4102 + ifAsiLinkStatus OBJECT-TYPE + SYNTAX INTEGER + { + linkOk(1), + linkDown(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "ASI link status" + ::= { ifStatusEntry 4102 } + + + -- 1.3.6.1.4.1.3715.17.5.3.1.4226 + ifLinkStatus OBJECT-TYPE + SYNTAX INTEGER + { + linkOk(1), + linkDown(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Interface link status" + ::= { ifStatusEntry 4226 } + + + + + -- 1.3.6.1.4.1.3715.17.5.4 + tsStatusTable OBJECT-TYPE + SYNTAX SEQUENCE OF TsStatusEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION " " + ::= { statusFlags 4 } + + + -- 1.3.6.1.4.1.3715.17.5.4.1 + tsStatusEntry OBJECT-TYPE + SYNTAX TsStatusEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION " " + INDEX { moduleId, ifDirection, ifId } + ::= { tsStatusTable 1 } + + + TsStatusEntry ::= + SEQUENCE { + tsPidRemappingStatus + INTEGER, + tsManualTableInsertStatus + INTEGER, + tsPassthruDupStatus + INTEGER, + tsSyncStatus + INTEGER, + tsRxStatus + INTEGER, + tsInputBufferStatus + INTEGER, + tsNetworkStatus + INTEGER, + tsPsisiCapaStatus + INTEGER, + tsMultiplexDiscardStatus + INTEGER, + tsMultiplexDelayStatus + INTEGER, + tsCbrOversubscriptionStatus + INTEGER, + tsCbrDiscardStatus + INTEGER, + tsIpInputCapaStatus + INTEGER, + tsEitReinsertCapaStatus + INTEGER, + tsSectionCapaStatus + INTEGER, + tsRtpInputStatus + INTEGER, + tsRtpSeqStatus + INTEGER, + tsTdtTotGenStatus + INTEGER, + tsSttGenStatus + INTEGER, + tsFecPacketCorrectionStatus + INTEGER, + tsFecInputAnomalyStatus + INTEGER, + tsFecCorrectionCapacityStatus + INTEGER, + tsIpMirrorOutputPacketLossStatus + INTEGER + } + + -- 1.3.6.1.4.1.3715.17.5.4.1.5 + tsPidRemappingStatus OBJECT-TYPE + SYNTAX INTEGER + { + pidNominal(1), + pidRemapped(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "TS PID remapping status" + ::= { tsStatusEntry 5 } + + + -- 1.3.6.1.4.1.3715.17.5.4.1.8 + tsManualTableInsertStatus OBJECT-TYPE + SYNTAX INTEGER + { + insertOk(1), + insertFailure(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "TS manual table insertion status" + ::= { tsStatusEntry 8 } + + + -- 1.3.6.1.4.1.3715.17.5.4.1.11 + tsPassthruDupStatus OBJECT-TYPE + SYNTAX INTEGER + { + servicesNominal(1), + servicesBlocked(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "TS output service passthrough duplication status" + ::= { tsStatusEntry 11 } + + + -- 1.3.6.1.4.1.3715.17.5.4.1.4098 + tsSyncStatus OBJECT-TYPE + SYNTAX INTEGER + { + syncOk(1), + noSync(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "TS sync status" + ::= { tsStatusEntry 4098 } + + + -- 1.3.6.1.4.1.3715.17.5.4.1.4099 + tsRxStatus OBJECT-TYPE + SYNTAX INTEGER + { + rxNominal(1), + rxErrors(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "TS Rx error status" + ::= { tsStatusEntry 4099 } + + + -- 1.3.6.1.4.1.3715.17.5.4.1.4100 + tsInputBufferStatus OBJECT-TYPE + SYNTAX INTEGER + { + bufferNominal(1), + bufferOverflow(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "TS input buffer status" + ::= { tsStatusEntry 4100 } + + + -- 1.3.6.1.4.1.3715.17.5.4.1.4103 + tsNetworkStatus OBJECT-TYPE + SYNTAX INTEGER + { + netOk(1), + netForbidden(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "TS network ID status" + ::= { tsStatusEntry 4103 } + + + -- 1.3.6.1.4.1.3715.17.5.4.1.4109 + tsPsisiCapaStatus OBJECT-TYPE + SYNTAX INTEGER + { + capacityNominal(1), + capacityExceeded(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "TS PSI/SI insertion capacity status" + ::= { tsStatusEntry 4109 } + + + -- 1.3.6.1.4.1.3715.17.5.4.1.4110 + tsMultiplexDiscardStatus OBJECT-TYPE + SYNTAX INTEGER + { + muxNominal(1), + muxPacketsDiscarded(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "TS multiplex packet discard status" + ::= { tsStatusEntry 4110 } + + + -- 1.3.6.1.4.1.3715.17.5.4.1.4228 + tsMultiplexDelayStatus OBJECT-TYPE + SYNTAX INTEGER + { + muxNominal(1), + muxPacketsDelayed(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "TS multiplex packet delay status" + ::= { tsStatusEntry 4228 } + + + -- 1.3.6.1.4.1.3715.17.5.4.1.4229 + tsCbrOversubscriptionStatus OBJECT-TYPE + SYNTAX INTEGER + { + cbrNominal(1), + cbrOversubscription(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "TS CBR oversubscription status" + ::= { tsStatusEntry 4229 } + + + -- 1.3.6.1.4.1.3715.17.5.4.1.4236 + tsCbrDiscardStatus OBJECT-TYPE + SYNTAX INTEGER + { + cbrNominal(1), + cbrPacketsDiscarded(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "TS CBR packet discard due to oversubscription status" + ::= { tsStatusEntry 4236 } + + + -- 1.3.6.1.4.1.3715.17.5.4.1.4238 + tsIpInputCapaStatus OBJECT-TYPE + SYNTAX INTEGER + { + capacityNominal(1), + capacityExceeded(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "TS IP input capacity status" + ::= { tsStatusEntry 4238 } + + + -- 1.3.6.1.4.1.3715.17.5.4.1.4239 + tsEitReinsertCapaStatus OBJECT-TYPE + SYNTAX INTEGER + { + capacityNominal(1), + capacityExceeded(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "TS EIT reinsert capacity status" + ::= { tsStatusEntry 4239 } + + + -- 1.3.6.1.4.1.3715.17.5.4.1.4240 + tsSectionCapaStatus OBJECT-TYPE + SYNTAX INTEGER + { + capacityNominal(1), + capacityExceeded(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "TS section processing capacity status" + ::= { tsStatusEntry 4240 } + + + -- 1.3.6.1.4.1.3715.17.5.4.1.4241 + tsRtpInputStatus OBJECT-TYPE + SYNTAX INTEGER + { + inputOk(1), + inputPacketsDropped(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "TS RTP input packet droip status" + ::= { tsStatusEntry 4241 } + + + -- 1.3.6.1.4.1.3715.17.5.4.1.4242 + tsRtpSeqStatus OBJECT-TYPE + SYNTAX INTEGER + { + seqOk(1), + seqAnomalies(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "TS RTP input packet sequence anomaly status" + ::= { tsStatusEntry 4242 } + + + -- 1.3.6.1.4.1.3715.17.5.4.1.4246 + tsTdtTotGenStatus OBJECT-TYPE + SYNTAX INTEGER + { + tdtTotOk(1), + tdtTotNotGenerated(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "TS output TDT/TOT table generation status" + ::= { tsStatusEntry 4246 } + + + -- 1.3.6.1.4.1.3715.17.5.4.1.4261 + tsSttGenStatus OBJECT-TYPE + SYNTAX INTEGER + { + sttOk(1), + sttNotGenerated(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "TS output STT table generation status" + ::= { tsStatusEntry 4261 } + + + -- 1.3.6.1.4.1.3715.17.5.4.1.4266 + tsFecPacketCorrectionStatus OBJECT-TYPE + SYNTAX INTEGER + { + packetsNominal(1), + fecCorrectedPackets(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Status flag for FEC correcting packets" + ::= { tsStatusEntry 4266 } + + + -- 1.3.6.1.4.1.3715.17.5.4.1.4267 + tsFecInputAnomalyStatus OBJECT-TYPE + SYNTAX INTEGER + { + fecInputNominal(1), + fecInputAnomalies(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Status flag for FEC input anomaly detection" + ::= { tsStatusEntry 4267 } + + + -- 1.3.6.1.4.1.3715.17.5.4.1.4268 + tsFecCorrectionCapacityStatus OBJECT-TYPE + SYNTAX INTEGER + { + correctionCapacityNominal(1), + correctionCapacityExceeded(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Fec input packets correction capacity status" + ::= { tsStatusEntry 4268 } + + + -- 1.3.6.1.4.1.3715.17.5.4.1.4297 + tsIpMirrorOutputPacketLossStatus OBJECT-TYPE + SYNTAX INTEGER + { + ipOutputNominal(1), + ipOutputPacketsDiscarded(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Status flag for IP mirror output packet discarding" + ::= { tsStatusEntry 4297 } + + + + -- 1.3.6.1.4.1.3715.17.5.5 + serviceStatusTable OBJECT-TYPE + SYNTAX SEQUENCE OF ServiceStatusEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION " " + ::= { statusFlags 5 } + + + -- 1.3.6.1.4.1.3715.17.5.5.1 + serviceStatusEntry OBJECT-TYPE + SYNTAX ServiceStatusEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION " " + INDEX { moduleId, ifDirection, ifId, serviceId } + ::= { serviceStatusTable 1 } + + + ServiceStatusEntry ::= + SEQUENCE { + serviceId + INTEGER, + serviceStatus + INTEGER + } + + -- 1.3.6.1.4.1.3715.17.5.5.1.1 + serviceId OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Service identifier" + ::= { serviceStatusEntry 1 } + + + -- 1.3.6.1.4.1.3715.17.5.5.1.3 + serviceStatus OBJECT-TYPE + SYNTAX INTEGER + { + servicePresent(1), + serviceMissing(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Service status" + ::= { serviceStatusEntry 3 } + + + + -- 1.3.6.1.4.1.3715.17.5.6 + pidStatusTable OBJECT-TYPE + SYNTAX SEQUENCE OF PidStatusEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION " " + ::= { statusFlags 6 } + + + -- 1.3.6.1.4.1.3715.17.5.6.1 + pidStatusEntry OBJECT-TYPE + SYNTAX PidStatusEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION " " + INDEX { moduleId, ifDirection, ifId, pId } + ::= { pidStatusTable 1 } + + + PidStatusEntry ::= + SEQUENCE { + pId + INTEGER, + pidStatus + INTEGER + } + + -- 1.3.6.1.4.1.3715.17.5.6.1.1 + pId OBJECT-TYPE + SYNTAX INTEGER (1..65535) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Program Identifier" + ::= { pidStatusEntry 1 } + + + -- 1.3.6.1.4.1.3715.17.5.6.1.2 + pidStatus OBJECT-TYPE + SYNTAX INTEGER + { + pidPresent(1), + pidMissing(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "PID status" + ::= { pidStatusEntry 2 } + + END + +-- +-- TELESTE-LUMINATO-MIB.mib +-- diff --git a/MIBS/teleste/TELESTE-LUMINATO-MIB2 b/MIBS/teleste/TELESTE-LUMINATO-MIB2 new file mode 100644 index 0000000..b9a14c2 --- /dev/null +++ b/MIBS/teleste/TELESTE-LUMINATO-MIB2 @@ -0,0 +1,2817 @@ +--
+-- TELESTE-LUMINATO-MIB2.mib
+--
+-- *****************************************************************************
+-- Copyright (c) 2000-2012 by:
+--
+-- Teleste Corporation
+-- Seponkatu 1
+-- FIN-20660 Littoinen, Finland
+-- tel. +358 2 2605 611
+-- url: http://www.teleste.com
+--
+-- Description: Objects for Luminato
+--
+-- Revision History:
+-- -----------------
+-- 1.0 27.03.2012 Sergey Egorov
+-- - Initial release
+-- ****************************************************************************
+--
+
+ TELESTE-LUMINATO-MIB2 DEFINITIONS ::= BEGIN
+
+ IMPORTS
+ OBJECT-TYPE
+ FROM RFC-1212
+ NOTIFICATION-TYPE
+ FROM SNMPv2-SMI
+ TimeTicks
+ FROM RFC1155-SMI
+ DisplayString
+ FROM RFC1213-MIB
+ Unsigned32
+ FROM SNMPv2-SMI
+ luminato
+ FROM TELESTE-ROOT-MIB;
+
+
+
+--
+-- Node definitions
+--
+ -- Traps node
+ -- 1.3.6.1.4.1.3715.17.4
+ notifications OBJECT IDENTIFIER ::= { luminato 4 }
+
+ -- Params node
+ -- 1.3.6.1.4.1.3715.17.4.1
+ params OBJECT IDENTIFIER ::= { notifications 1 }
+
+ -- Severity
+ -- 1.3.6.1.4.1.3715.17.4.1.1
+ severity OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ severityEmergency(0),
+ severityAlert(1),
+ severityCritical(2),
+ severityError(3),
+ severityWarning(4),
+ severityNotice(5),
+ severityInformational(6),
+ severityDebug(7),
+ severityNominal(8)
+ }
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "Severity level of alarm. severityNominal(8) means that alarm condition is removed."
+ ::= { params 1 }
+
+ -- Module
+ -- 1.3.6.1.4.1.3715.17.4.1.2
+ module OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ moduleChassis(0),
+ moduleSlot1(1),
+ moduleSlot2(2),
+ moduleSlot3(3),
+ moduleSlot4(4),
+ moduleSlot5(5),
+ moduleSlot6(6),
+ modulePsu(7)
+ }
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "Module which cause the alarm."
+ ::= { params 2 }
+
+ -- description
+ -- 1.3.6.1.4.1.3715.17.4.1.8
+ description OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { params 8 }
+ -- reason
+ -- 1.3.6.1.4.1.3715.17.4.1.10
+ reason OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "Reason code."
+ ::= { params 10 }
+
+ paramTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ParamEntry
+ ACCESS not-accessible
+ STATUS optional
+ ::= { params 11 }
+
+ paramEntry OBJECT-TYPE
+ SYNTAX ParamEntry
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ INDEX { paramIdx }
+ ::= { paramTable 1 }
+
+ ParamEntry ::=
+ SEQUENCE {
+ paramIdx
+ INTEGER,
+ paramValue
+ Unsigned32
+ }
+
+ paramIdx OBJECT-TYPE
+ SYNTAX INTEGER (1..4)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Index of the table."
+ ::= { paramEntry 1 }
+
+ paramValue OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "Value of param."
+ ::= { paramEntry 2 }
+
+ -- Traps node
+ -- 1.3.6.1.4.1.3715.17.4.2
+ traps OBJECT IDENTIFIER ::= { notifications 2 }
+ generic OBJECT IDENTIFIER ::= { traps 1 }
+
+ -- 1.3.6.1.4.1.3715.17.4.2.1.1
+ extendedAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The generic SNMP trap that is generated when an alarm event is found."
+ ::= { generic 1 }
+
+ specific OBJECT IDENTIFIER ::= { traps 2 }
+
+-- %FORMAT_TRAP_BEGIN%
+
+-- extended%NAME%AlarmEvent NOTIFICATION-TYPE
+-- OBJECTS {
+-- severity,
+-- module,
+-- reason,
+-- description,
+-- paramTable
+-- }
+-- STATUS current
+-- DESCRIPTION
+-- "The SNMP trap that is generated when an alarm event with id %ID% - '%ID_TEXT%' is found."
+-- ::= { specific %ID% }
+-- %FORMAT_TRAP_END%
+-- %BEGIN_DEFINE_TRAPS%
+
+ extendedPidMissingAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 2 - 'PID missing' is found."
+ ::= { specific 2 }
+
+ extendedServiceMissingAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 3 - 'Service missing' is found."
+ ::= { specific 3 }
+
+ extendedPidConflictAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4 - 'PID conflict' is found."
+ ::= { specific 4 }
+
+ extendedTemperatureTooHighAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 6 - 'Temperature too high' is found."
+ ::= { specific 6 }
+
+ extendedTemperatureTooLowAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 7 - 'Temperature too low' is found."
+ ::= { specific 7 }
+
+ extendedManualTableInsertionFailedAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 8 - 'Manual table insertion failed' is found."
+ ::= { specific 8 }
+
+ extendedAlertMessageAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 10 - 'Alert message' is found."
+ ::= { specific 10 }
+
+ extendedServicesPassthroughAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 11 - 'Services passthrough - duplicated SID from input stream not passed through' is found."
+ ::= { specific 11 }
+
+ extendedEcmStreamCannotBeAttachedToIncompatibleCwgAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 13 - 'ECM stream cannot be attached to incompatible CWG' is found."
+ ::= { specific 13 }
+
+ extendedPsigTableInsertionFailedAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 15 - 'Psig table insertion failed' is found."
+ ::= { specific 15 }
+
+ extendedPsiTableCaptureFailureAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 17 - 'PSI table capture failure' is found."
+ ::= { specific 17 }
+
+ extendedSignalMissingAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 18 - 'Signal missing' is found."
+ ::= { specific 18 }
+
+ extendedNoTsSyncAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 19 - 'No TS sync' is found."
+ ::= { specific 19 }
+
+ extendedTsRxErrorsAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 20 - 'TS RX errors' is found."
+ ::= { specific 20 }
+
+ extendedTsInputBufferOverflowAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 21 - 'TS input buffer overflow' is found."
+ ::= { specific 21 }
+
+ extendedAsiLinkDownAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 22 - 'ASI link down' is found."
+ ::= { specific 22 }
+
+ extendedForbiddenNetworkAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 23 - 'Forbidden network' is found."
+ ::= { specific 23 }
+
+ extendedSidConflictAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 24 - 'SID conflict' is found."
+ ::= { specific 24 }
+
+ extendedLinkMissingAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 25 - 'Link missing' is found."
+ ::= { specific 25 }
+
+ extendedEcmMissingAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 26 - 'ECM missing' is found."
+ ::= { specific 26 }
+
+ extendedScramblingConflictInSharedComponentAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 27 - 'Scrambling conflict in shared component' is found."
+ ::= { specific 27 }
+
+ extendedScrambledSharedComponentAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 28 - 'Scrambled shared component' is found."
+ ::= { specific 28 }
+
+ extendedUsedInputIsNotSptsAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 29 - 'Used input is not SPTS' is found."
+ ::= { specific 29 }
+
+ extendedConfigurationErrorAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 30 - 'Configuration error' is found."
+ ::= { specific 30 }
+
+ extendedDescramblingFailedAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 31 - 'Descrambling failed' is found."
+ ::= { specific 31 }
+
+ extendedCwGroupConflictAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 32 - 'CW group conflict' is found."
+ ::= { specific 32 }
+
+ extendedInvalidSdtTemplateAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 33 - 'Invalid SDT template' is found."
+ ::= { specific 33 }
+
+ extendedCannotDescrambleDueToCamRoutingAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 34 - 'Cannot descramble due to CAM routing' is found."
+ ::= { specific 34 }
+
+ extendedRedundancyActivatedAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 35 - 'Redundancy activated' is found."
+ ::= { specific 35 }
+
+ extendedRtpInputPacketSequenceAnomaliesDetectedAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 36 - 'RTP input packet sequence anomalies detected' is found."
+ ::= { specific 36 }
+
+ extendedRtpInputErrorsDroppedPacketsAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 37 - 'RTP input errors, dropped packets' is found."
+ ::= { specific 37 }
+
+ extendedFecHasCorrectedPacketsAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 38 - 'FEC has corrected packets' is found."
+ ::= { specific 38 }
+
+ extendedFecInputAnomaliesDetectedAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 39 - 'FEC input anomalies detected' is found."
+ ::= { specific 39 }
+
+ extendedFecErrorCorrectionCapacityExceededAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 40 - 'FEC error correction capacity exceeded' is found."
+ ::= { specific 40 }
+
+ extendedTooManyServicesAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 42 - 'Too many services' is found."
+ ::= { specific 42 }
+
+ extendedLowSignalLevelAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 43 - 'Low signal level' is found."
+ ::= { specific 43 }
+
+ extendedSignalMutedAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 44 - 'Signal muted' is found."
+ ::= { specific 44 }
+
+ extendedProidiomScramblingDisabledAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 45 - 'Pro:Idiom scrambling disabled' is found."
+ ::= { specific 45 }
+
+ extendedVmxConnectionLostAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 46 - 'VMX connection lost' is found."
+ ::= { specific 46 }
+
+ extendedControlWordErrorAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 47 - 'Control word error' is found."
+ ::= { specific 47 }
+
+ extendedOutputServiceCapacityExceededAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 48 - 'Output service capacity exceeded' is found."
+ ::= { specific 48 }
+
+ extendedLowSignalQualityAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 49 - 'Low signal quality' is found."
+ ::= { specific 49 }
+
+ extendedModuleOffAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4096 - 'Off' is found."
+ ::= { specific 4096 }
+
+ extendedPidCapacityExceededAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4104 - 'PID capacity exceeded' is found."
+ ::= { specific 4104 }
+
+ extendedPsiSiCaptureCapacityExceededAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4105 - 'PSI/SI capture capacity exceeded' is found."
+ ::= { specific 4105 }
+
+ extendedOutOfServiceIdsAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4106 - 'Out of service ID's' is found."
+ ::= { specific 4106 }
+
+ extendedCaModuleMissingAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4108 - 'CA module missing' is found."
+ ::= { specific 4108 }
+
+ extendedPsiSiInsertCapacityExceededAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4109 - 'PSI/SI insert capacity exceeded' is found."
+ ::= { specific 4109 }
+
+ extendedMultiplexOversubscriptionPacketsDiscardedAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4110 - 'Multiplex oversubscription, packets discarded' is found."
+ ::= { specific 4110 }
+
+ extendedUnknownModuleAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4111 - 'Unknown module' is found."
+ ::= { specific 4111 }
+
+ extendedMainVoltageTooHighAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4112 - 'Main voltage too high' is found."
+ ::= { specific 4112 }
+
+ extendedMainVoltageTooLowAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4113 - 'Main voltage too low' is found."
+ ::= { specific 4113 }
+
+ extendedCurrentTooHighAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4114 - 'Current too high' is found."
+ ::= { specific 4114 }
+
+ extendedCurrentTooLowAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4115 - 'Current too low' is found."
+ ::= { specific 4115 }
+
+ extendedDaemonInitializationFailedAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4127 - 'Daemon initialization failed' is found."
+ ::= { specific 4127 }
+
+ extendedDeviceDriverFailureAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4129 - 'Device driver failure' is found."
+ ::= { specific 4129 }
+
+ extendedHardwareFailureAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4130 - 'Hardware failure' is found."
+ ::= { specific 4130 }
+
+ extendedFanFailureAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4131 - 'Fan failure' is found."
+ ::= { specific 4131 }
+
+ extendedRunningOnBackupPowerAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4132 - 'Running on backup power' is found."
+ ::= { specific 4132 }
+
+ extendedPowerSupplyOverloadedAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4133 - 'Power supply overloaded' is found."
+ ::= { specific 4133 }
+
+ extendedBootingUpAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4134 - 'Booting up' is found."
+ ::= { specific 4134 }
+
+ extendedBootFailedRetryingAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4135 - 'Boot failed: retrying' is found."
+ ::= { specific 4135 }
+
+ extendedBootFailedAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4136 - 'Boot failed' is found."
+ ::= { specific 4136 }
+
+ extendedShuttingDownAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4137 - 'Shutting down' is found."
+ ::= { specific 4137 }
+
+ extendedConnectionLostAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4138 - 'Connection lost' is found."
+ ::= { specific 4138 }
+
+ extendedIncompatibleModuleDisabledAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4139 - 'Incompatible module disabled' is found."
+ ::= { specific 4139 }
+
+ extendedFailedToBootAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4141 - 'Failed to boot' is found."
+ ::= { specific 4141 }
+
+ extendedUpcTooLowInputPowerAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4147 - 'UPC too low input power' is found."
+ ::= { specific 4147 }
+
+ extendedUpcTooHighInputPowerAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4148 - 'UPC too high input power' is found."
+ ::= { specific 4148 }
+
+ extendedCalibrationDataMissingAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4149 - 'Calibration data missing' is found."
+ ::= { specific 4149 }
+
+ extendedCalibrationCheckSkippedAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4150 - 'Calibration check skipped' is found."
+ ::= { specific 4150 }
+
+ extendedDescramblingFailureAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4151 - 'Descrambling failure' is found."
+ ::= { specific 4151 }
+
+ extendedBackupSwitchedOverToBackupDeviceAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4153 - 'Backup: Switched over to backup device' is found."
+ ::= { specific 4153 }
+
+ extendedFailedToQuerySomeOfTheNitDataAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4157 - 'Failed to query some of the NIT data' is found."
+ ::= { specific 4157 }
+
+ extendedNitWizardFailureAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4158 - 'NIT wizard failure' is found."
+ ::= { specific 4158 }
+
+ extendedDuplicateFrequencyInTwoOrMoreSelectedQamOutputsAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4159 - 'Duplicate frequency in two or more selected QAM outputs' is found."
+ ::= { specific 4159 }
+
+ extendedCannotResolveTableVersionUsingDefaultAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4160 - 'Cannot resolve table version: using default' is found."
+ ::= { specific 4160 }
+
+ extendedUnsupportedConfigurationAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4175 - 'Unsupported configuration' is found."
+ ::= { specific 4175 }
+
+ extendedFrequencyOutOfRangeAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4176 - 'Frequency out of range' is found."
+ ::= { specific 4176 }
+
+ extendedOutputPowerOutOfRangeAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4177 - 'Output power out of range' is found."
+ ::= { specific 4177 }
+
+ extendedSymbolrateOutOfRangeAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4178 - 'Symbolrate out of range' is found."
+ ::= { specific 4178 }
+
+ extendedChannelDistanceTooNarrowAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4179 - 'Channel distance too narrow' is found."
+ ::= { specific 4179 }
+
+ extendedInvalidLnbVoltageConfigurationAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4180 - 'Invalid LNB voltage configuration' is found."
+ ::= { specific 4180 }
+
+ extendedInvalidFecRateForSelectedModulationAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4181 - 'Invalid FEC rate for selected modulation' is found."
+ ::= { specific 4181 }
+
+ extendedLnbCurrentAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4182 - 'LNB current' is found."
+ ::= { specific 4182 }
+
+ extendedFrequencyOffsetAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4183 - 'Frequency offset' is found."
+ ::= { specific 4183 }
+
+ extendedRestartingDescramblingAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4185 - 'Restarting descrambling' is found."
+ ::= { specific 4185 }
+
+ extendedRebootingCamAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4186 - 'Rebooting CAM' is found."
+ ::= { specific 4186 }
+
+ extendedEcmgFailureAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4187 - 'ECMG failure' is found."
+ ::= { specific 4187 }
+
+ extendedEcmStreamFailureAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4188 - 'ECM stream failure' is found."
+ ::= { specific 4188 }
+
+ extendedEmmFailureAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4189 - 'EMM failure' is found."
+ ::= { specific 4189 }
+
+ extendedEmmStreamFailureAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4190 - 'EMM stream failure' is found."
+ ::= { specific 4190 }
+
+ extendedEcmgNotConnectedAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4191 - 'ECMG not connected' is found."
+ ::= { specific 4191 }
+
+ extendedEmmNotConnectedAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4192 - 'EMM not connected' is found."
+ ::= { specific 4192 }
+
+ extendedScsNotLicensedAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4193 - 'SCS not licensed' is found."
+ ::= { specific 4193 }
+
+ extendedEcmgSwitchedToSpareServerAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4194 - 'ECMG switched to spare server' is found."
+ ::= { specific 4194 }
+
+ extendedUpdatedBootLoaderAvailableAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4195 - 'Updated boot loader available' is found."
+ ::= { specific 4195 }
+
+ extendedUpdatingStage1BootLoaderAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4196 - 'Updating stage 1 boot loader' is found."
+ ::= { specific 4196 }
+
+ extendedUpdatingStage2BootLoaderAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4197 - 'Updating stage 2 boot loader' is found."
+ ::= { specific 4197 }
+
+ extendedFailedToUpdateStage1BootLoaderAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4198 - 'Failed to update stage 1 boot loader' is found."
+ ::= { specific 4198 }
+
+ extendedFailedToUpdateStage2BootLoaderAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4199 - 'Failed to update stage 2 boot loader' is found."
+ ::= { specific 4199 }
+
+ extendedBackupActiveBackupAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4203 - 'Backup: Active Backup' is found."
+ ::= { specific 4203 }
+
+ extendedConfiguringModuleAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4205 - 'Configuring module' is found."
+ ::= { specific 4205 }
+
+ extendedNoModuleAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4206 - 'No module' is found."
+ ::= { specific 4206 }
+
+ extendedProcessStartedAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4208 - 'Process started' is found."
+ ::= { specific 4208 }
+
+ extendedBackupLicenseMissingAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4209 - 'Backup license missing' is found."
+ ::= { specific 4209 }
+
+ extendedMultiplexingLicenseMissingAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4211 - 'Multiplexing license missing' is found."
+ ::= { specific 4211 }
+
+ extendedDemultiplexingLicenseMissingAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4212 - 'Demultiplexing license missing' is found."
+ ::= { specific 4212 }
+
+ extendedDvbProcessingLicenseMissingAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4213 - 'DVB processing license missing' is found."
+ ::= { specific 4213 }
+
+ extendedMsdLicenseMissingAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4214 - 'MSD license missing' is found."
+ ::= { specific 4214 }
+
+ extendedDvbS2LicenseMissingAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4215 - 'DVB-S2 license missing' is found."
+ ::= { specific 4215 }
+
+ extendedScramblingLicenseMissingAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4216 - 'Scrambling license missing' is found."
+ ::= { specific 4216 }
+
+ extendedScsLicenseMissingAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4217 - 'SCS license missing' is found."
+ ::= { specific 4217 }
+
+ extendedUserFromGroupAdminIsUsingCliAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4218 - 'User from group admin is using CLI' is found."
+ ::= { specific 4218 }
+
+ extendedUserFromGroupInstallIsUsingCliAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4219 - 'User from group install is using CLI' is found."
+ ::= { specific 4219 }
+
+ extendedUserFromGroupOperIsUsingCliAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4220 - 'User from group oper is using CLI' is found."
+ ::= { specific 4220 }
+
+ extendedUserFromGroupMonitorIsUsingCliAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4221 - 'User from group monitor is using CLI' is found."
+ ::= { specific 4221 }
+
+ extendedExtIoSignaledAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4223 - 'EXT IO Signaled' is found."
+ ::= { specific 4223 }
+
+ extendedExtIoBackupPowerSupplyFailureAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4224 - 'EXT IO Backup power supply failure' is found."
+ ::= { specific 4224 }
+
+ extendedExtIoIntrusionDetectedAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4225 - 'EXT IO Intrusion detected' is found."
+ ::= { specific 4225 }
+
+ extendedRedundancyFailedAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4227 - 'Redundancy failed' is found."
+ ::= { specific 4227 }
+
+ extendedMultiplexOversubscriptionPacketsDelayedAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4228 - 'Multiplex oversubscription, packets delayed' is found."
+ ::= { specific 4228 }
+
+ extendedCbrOutputOversubscriptionAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4229 - 'CBR output oversubscription' is found."
+ ::= { specific 4229 }
+
+ extendedBackupHwDoesNotSupportSelectedDeviceRoleAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4230 - 'Backup: HW does not support selected device role, fallback to Standalone role' is found."
+ ::= { specific 4230 }
+
+ extendedSoftwareUpdateInProgressAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4231 - 'Software update in progress' is found."
+ ::= { specific 4231 }
+
+ extendedSoftwareUpdateReadyWaitingForRebootToCompleteAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4232 - 'Software update ready. Waiting for reboot to complete' is found."
+ ::= { specific 4232 }
+
+ extendedSoftwareUpdateFailedAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4233 - 'Software update failed' is found."
+ ::= { specific 4233 }
+
+ extendedBackupModuleHwDoesNotSupportSelectedOnePlusOneBackupRoleAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4234 - 'Backup: Module HW does not support selected 1+1 backup role' is found."
+ ::= { specific 4234 }
+
+ extendedEitProcessingLicenseMissingAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4235 - 'EIT processing license missing' is found."
+ ::= { specific 4235 }
+
+ extendedCbrOutputOversubscriptionPacketsDiscardedAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4236 - 'CBR output oversubscription, packets discarded' is found."
+ ::= { specific 4236 }
+
+ extendedIpInputCapacityExceededAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4238 - 'IP input capacity exceeded' is found."
+ ::= { specific 4238 }
+
+ extendedEitReinsertCapacityExceededAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4239 - 'EIT reinsert capacity exceeded' is found."
+ ::= { specific 4239 }
+
+ extendedDvbTimeMissingAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4243 - 'DVB time missing' is found."
+ ::= { specific 4243 }
+
+ extendedDvbT2LicenseMissingAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4244 - 'DVB-T2 license missing' is found."
+ ::= { specific 4244 }
+
+ extendedDcFeedCurrentAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4245 - 'DC feed current' is found."
+ ::= { specific 4245 }
+
+ extendedNotGeneratingTdtTotTableWaitingForCorrectSystemTimeAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4246 - 'Not generating TDT/TOT table. Waiting for correct system time' is found."
+ ::= { specific 4246 }
+
+ extendedDataPlpIdSelectionRequiredAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4247 - 'Data PLP ID selection required' is found."
+ ::= { specific 4247 }
+
+ extendedDataPlpIdSelectionNotValidAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4248 - 'Data PLP ID selection not valid' is found."
+ ::= { specific 4248 }
+
+ extendedHierarchyHpSelectedForNonAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4249 - 'Hierarchy HP selected for non-hierarchical transmission' is found."
+ ::= { specific 4249 }
+
+ extendedBackupVoltageTooHighAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4253 - 'Backup voltage too high' is found."
+ ::= { specific 4253 }
+
+ extendedBackupVoltageTooLowAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4254 - 'Backup voltage too low' is found."
+ ::= { specific 4254 }
+
+ extendedCamFailureActionTakenRestartingDescramblingAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4256 - 'CAM Failure action taken: restarting descrambling' is found."
+ ::= { specific 4256 }
+
+ extendedCamFailureActionTakenRebootingCaModuleAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4257 - 'CAM Failure action taken: rebooting CA module' is found."
+ ::= { specific 4257 }
+
+ extendedCaMenuIsOpenAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4258 - 'CA menu is open' is found."
+ ::= { specific 4258 }
+
+ extendedNitSidConflictAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4260 - 'SID conflict in output' is found."
+ ::= { specific 4260 }
+
+ extendedNotGeneratingSttTableWaitingForCorrectSystemTimeAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4261 - 'Not generating STT table. Waiting for correct system time' is found."
+ ::= { specific 4261 }
+
+ extendedNumberOfFecLicensesExceededAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4262 - 'Number of FEC licenses exceeded' is found."
+ ::= { specific 4262 }
+
+ extendedErrorCorrectionOverloadTooManySimultaneousMissingPacketsAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4263 - 'Error correction overload. Too many simultaneous missing packets.' is found."
+ ::= { specific 4263 }
+
+ extendedFecPacketsDiscardedModuleBitrateTooHighAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4264 - 'FEC packets discarded. Module bitrate too high.' is found."
+ ::= { specific 4264 }
+
+ extendedMediaPacketsDiscardedModuleBitrateTooHighAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4265 - 'Media packets discarded. Module bitrate too high.' is found."
+ ::= { specific 4265 }
+
+ extendedSfpLinkDownAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4269 - 'SFP link down' is found."
+ ::= { specific 4269 }
+
+ extendedBackupsyncTurnedOffAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4272 - 'BackupSync: Turned off' is found."
+ ::= { specific 4272 }
+
+ extendedBackupsyncManualModeAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4273 - 'BackupSync: Manual mode' is found."
+ ::= { specific 4273 }
+
+ extendedBackupsyncAutomaticModeAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4274 - 'BackupSync: Automatic mode' is found."
+ ::= { specific 4274 }
+
+ extendedBackupsyncConfigurationWillBeSynchronizedAutomaticallyAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4275 - 'BackupSync: Configuration will be synchronized automatically' is found."
+ ::= { specific 4275 }
+
+ extendedBackupsyncSynchronizingAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4276 - 'BackupSync: Synchronizing' is found."
+ ::= { specific 4276 }
+
+ extendedBackupsyncSwCompatibilityCheckAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4278 - 'BackupSync: SW compatibility check' is found."
+ ::= { specific 4278 }
+
+ extendedBackupsyncHwCompatibilityCheckAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4279 - 'BackupSync: HW compatibility check' is found."
+ ::= { specific 4279 }
+
+ extendedBackupsyncConfigurationFaultAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4280 - 'BackupSync: Configuration fault' is found."
+ ::= { specific 4280 }
+
+ extendedBackupsyncConnectionLostAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4281 - 'BackupSync: Connection lost' is found."
+ ::= { specific 4281 }
+
+ extendedBackupsyncAutosyncNotPossibleFromBackupToMainAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4283 - 'BackupSync: Autosync not possible from backup to main' is found."
+ ::= { specific 4283 }
+
+ extendedBackupsyncRebootingPairDeviceToNewConfigurationAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4284 - 'BackupSync: Rebooting pair device to new configuration' is found."
+ ::= { specific 4284 }
+
+ extendedBackupsyncCheckLicenseCompatibilityAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4285 - 'BackupSync: Check license compatibility!' is found."
+ ::= { specific 4285 }
+
+ extendedBackupsyncLicenseCompatibilityCheckAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4286 - 'BackupSync: License compatibility check' is found."
+ ::= { specific 4286 }
+
+ extendedDeviceFirstBootActionsAreInProgressAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4288 - 'Device first boot actions are in progress' is found."
+ ::= { specific 4288 }
+
+ extendedDeviceConfigurationBackupInProgressAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4289 - 'Device configuration backup in progress' is found."
+ ::= { specific 4289 }
+
+ extendedDeviceConfigurationRestoreInProgressAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4290 - 'Device configuration restore in progress' is found."
+ ::= { specific 4290 }
+
+ extendedDeviceOtherSoftwareActivationAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4291 - 'Device other software activation' is found."
+ ::= { specific 4291 }
+
+ extendedTooManyOutputPidsConfiguredAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4292 - 'Too many output PIDs configured! Some PIDs are dropped.' is found."
+ ::= { specific 4292 }
+
+ extendedRebootRequestByUserAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4293 - 'Reboot request by user' is found."
+ ::= { specific 4293 }
+
+ extendedRemovedFromTheChassisAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4294 - 'Removed from the chassis' is found."
+ ::= { specific 4294 }
+
+ extendedInsertedIntoTheChassisAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4295 - 'Inserted into the chassis' is found."
+ ::= { specific 4295 }
+
+ extendedPacketsDiscardedInIpMirrorOutputsAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4297 - 'Packets discarded in IP mirror outputs' is found."
+ ::= { specific 4297 }
+
+ extendedAesLicenseMissingAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4298 - 'AES license missing' is found."
+ ::= { specific 4298 }
+
+ extendedSymbolRateTooHighForSelectedModulationSelectHighSpeedModulationModeToAvoidErrorsAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4299 - 'Symbol rate too high for selected modulation (tuner %6%). Select high speed modulation mode to avoid errors.' is found."
+ ::= { specific 4299 }
+
+ extendedEcmResponsesDelayedAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4300 - 'ECM responses delayed' is found."
+ ::= { specific 4300 }
+
+ extendedDisconnectedHostInMultichassisGroupAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4302 - 'Disconnected host(s) in multichassis group' is found."
+ ::= { specific 4302 }
+
+ extendedMultichassisConfigurationFailureAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4303 - 'Multichassis configuration failure' is found."
+ ::= { specific 4303 }
+
+ extendedSwVersionDifferenceWithinMultichassisGroupAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4304 - 'SW version difference within multichassis group' is found."
+ ::= { specific 4304 }
+
+ extendedSwVersionMismatchAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4305 - 'SW version mismatch (module %6%)' is found."
+ ::= { specific 4305 }
+
+ extendedEmergencySignalActivatedAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4307 - 'Emergency signal activated' is found."
+ ::= { specific 4307 }
+
+ extendedEmergencySignalMissingAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4308 - 'Emergency signal missing' is found."
+ ::= { specific 4308 }
+
+ extendedUnableToAddEmergencySignalAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4309 - 'Unable to add emergency signal' is found."
+ ::= { specific 4309 }
+
+ extendedNetworkInformationTableNeedsToBeUpdatedAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4310 - 'Network information table needs to be updated' is found."
+ ::= { specific 4310 }
+
+ extendedNfsMountFailureAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4311 - 'NFS mount failure' is found."
+ ::= { specific 4311 }
+
+ extendedEthernetInputBufferOverflowAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4312 - 'Ethernet input buffer overflow' is found."
+ ::= { specific 4312 }
+
+ extendedDvbAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4313 - 'DVB-Multi license missing' is found."
+ ::= { specific 4313 }
+
+ extendedPoweredOffAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4315 - 'Powered off' is found."
+ ::= { specific 4315 }
+
+ extendedPsu1NoModuleAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4316 - 'PSU 1: No module' is found."
+ ::= { specific 4316 }
+
+ extendedPsu2NoModuleAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4317 - 'PSU 2: No module' is found."
+ ::= { specific 4317 }
+
+ extendedPsu1VoltageMissingAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4318 - 'PSU 1: Voltage missing' is found."
+ ::= { specific 4318 }
+
+ extendedPsu2VoltageMissingAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4319 - 'PSU 2: Voltage missing' is found."
+ ::= { specific 4319 }
+
+ extendedPsu1VoltageLowAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4320 - 'PSU 1: Voltage low' is found."
+ ::= { specific 4320 }
+
+ extendedPsu2VoltageLowAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4321 - 'PSU 2: Voltage low' is found."
+ ::= { specific 4321 }
+
+ extendedPsu1FanFailureAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4322 - 'PSU 1: Fan failure (fan %6%)' is found."
+ ::= { specific 4322 }
+
+ extendedPsu2FanFailureAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4323 - 'PSU 2: Fan failure (fan %6%)' is found."
+ ::= { specific 4323 }
+
+ extendedBackupCableIsNotConnectedAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4324 - 'Backup: Cable is not connected' is found."
+ ::= { specific 4324 }
+
+ extendedUnableToAddMacAddressMappingAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4325 - 'Unable to add MAC address mapping' is found."
+ ::= { specific 4325 }
+
+ extendedFpgaPllNotLockedAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4327 - 'FPGA PLL not locked' is found."
+ ::= { specific 4327 }
+
+ extendedFpgaRegisterMissmatchAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4328 - 'FPGA register missmatch' is found."
+ ::= { specific 4328 }
+
+ extendedDepiLicenseMissingAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4329 - 'DEPI license missing' is found."
+ ::= { specific 4329 }
+
+ extendedXfiPortOverflowAlarmEvent NOTIFICATION-TYPE
+ OBJECTS {
+ severity,
+ module,
+ reason,
+ description,
+ paramTable
+ }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm event with id 4330 - 'XFI port overflow' is found."
+ ::= { specific 4330 }
+-- %END_DEFINE_TRAPS%
+
+ END
+
+--
+-- TELESTE-LUMINATO-MIB2.mib
+--
diff --git a/MIBS/teleste/TELESTE-ROOT-MIB b/MIBS/teleste/TELESTE-ROOT-MIB new file mode 100644 index 0000000..a002b3d --- /dev/null +++ b/MIBS/teleste/TELESTE-ROOT-MIB @@ -0,0 +1,206 @@ + TELESTE-ROOT-MIB DEFINITIONS ::= BEGIN + + IMPORTS + enterprises + FROM RFC1155-SMI + DisplayString + FROM RFC1213-MIB; + + + TDisplayString ::= OCTET STRING (SIZE (0..255)) + + TPhysAddress ::= OCTET STRING (SIZE (6)) + + Int8 ::= INTEGER (-128..127) + + Int16 ::= INTEGER (-32768..32768) + + Uint8 ::= INTEGER (0..255) + + Uint16 ::= INTEGER (0..65536) + + Uint32 ::= INTEGER (0..2147483647) + + DateAndTime ::= DisplayString (SIZE (16..28)) + +-- 'HMS style' value definition for status objects. + ValueStatus ::= INTEGER + { + valueNormal(1), + valueHIHI(2), + valueHi(3), + valueLo(4), + valueLOLO(5) + } + + +-- +-- Node definitions +-- + +-- +-- TELESTE root object identifier +-- + -- 1.3.6.1.4.1.3715 + teleste OBJECT IDENTIFIER ::= { enterprises 3715 } + + +-- +-- EMS server objects (SNMP Wizard) +-- + -- 1.3.6.1.4.1.3715.1 + ems OBJECT IDENTIFIER ::= { teleste 1 } + + +-- +-- Objects common to all teleste products/agents. +-- Deprecated 11.10.2001 and replaced with section Common. +-- + -- 1.3.6.1.4.1.3715.2 + gendata OBJECT IDENTIFIER ::= { teleste 2 } + + +-- +-- BK product family specific objects +-- + -- 1.3.6.1.4.1.3715.3 + bk OBJECT IDENTIFIER ::= { teleste 3 } + + +-- +-- BXX product family specific objects +-- + -- 1.3.6.1.4.1.3715.4 + bxx OBJECT IDENTIFIER ::= { teleste 4 } + + +-- +-- DVO product family specific objects +-- + -- 1.3.6.1.4.1.3715.5 + dvo OBJECT IDENTIFIER ::= { teleste 5 } + + +-- +-- DVX product family specific objects +-- + -- 1.3.6.1.4.1.3715.6 + dvx OBJECT IDENTIFIER ::= { teleste 6 } + + +-- +-- INF product family specific objects +-- + -- 1.3.6.1.4.1.3715.7 + inf OBJECT IDENTIFIER ::= { teleste 7 } + + +-- +-- ATMux product family specific objects +-- + -- 1.3.6.1.4.1.3715.8 + atmux OBJECT IDENTIFIER ::= { teleste 8 } + + +-- +-- Edge Access System Interface products. +-- + -- 1.3.6.1.4.1.3715.9 + easi OBJECT IDENTIFIER ::= { teleste 9 } + + +-- +-- EMT product family specific objects +-- + -- 1.3.6.1.4.1.3715.10 + emt OBJECT IDENTIFIER ::= { teleste 10 } + + +-- +-- ACx product family specific objects +-- + -- 1.3.6.1.4.1.3715.11 + acx OBJECT IDENTIFIER ::= { teleste 11 } + + +-- +-- EttH product family specific objects +-- + -- 1.3.6.1.4.1.3715.12 + etth OBJECT IDENTIFIER ::= { teleste 12 } + + +-- +-- HDO product family specific objects +-- + -- 1.3.6.1.4.1.3715.14 + hdo OBJECT IDENTIFIER ::= { teleste 14 } + + +-- +-- CFO product family specific objects +-- + -- 1.3.6.1.4.1.3715.15 + cfo OBJECT IDENTIFIER ::= { teleste 15 } + + +-- FTTH product family specific objects + -- 1.3.6.1.4.1.3715.16 + ftth OBJECT IDENTIFIER ::= { teleste 16 } + + + -- 1.3.6.1.4.1.3715.17 + luminato OBJECT IDENTIFIER ::= { teleste 17 } + + +-- +-- Objects common to all teleste products/agents. +-- + -- 1.3.6.1.4.1.3715.99 + common OBJECT IDENTIFIER ::= { teleste 99 } + + +-- +-- Functional object groups +-- + -- 1.3.6.1.4.1.3715.100 + functional OBJECT IDENTIFIER ::= { teleste 100 } + + + -- 1.3.6.1.4.1.3715.100.1 + hmsModem OBJECT IDENTIFIER ::= { functional 1 } + + + -- 1.3.6.1.4.1.3715.100.2 + spectrumAnalyser OBJECT IDENTIFIER ::= { functional 2 } + + + -- 1.3.6.1.4.1.3715.100.3 + pilotGenerator OBJECT IDENTIFIER ::= { functional 3 } + + + -- 1.3.6.1.4.1.3715.100.4 + ntpcontrol OBJECT IDENTIFIER ::= { functional 4 } + + + -- 1.3.6.1.4.1.3715.100.10 + hfcOptics OBJECT IDENTIFIER ::= { functional 10 } + + + -- 1.3.6.1.4.1.3715.100.20 + headEnd OBJECT IDENTIFIER ::= { functional 20 } + + +-- +-- Placeholder experimental and preliminary MIB modules. +-- + -- 1.3.6.1.4.1.3715.999 + experimental OBJECT IDENTIFIER ::= { teleste 999 } + + + + END + +-- +-- TELESTE-ROOT-MIB.mib +-- |