summaryrefslogtreecommitdiff
path: root/MIBS/telco-systems/binox/PRVT-TE-PARAM-MIB
diff options
context:
space:
mode:
authorDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
committerDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
commit98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch)
tree9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/telco-systems/binox/PRVT-TE-PARAM-MIB
downloadmibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.tar.gz
mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.zip
Initial commitHEADmain
Diffstat (limited to 'MIBS/telco-systems/binox/PRVT-TE-PARAM-MIB')
-rw-r--r--MIBS/telco-systems/binox/PRVT-TE-PARAM-MIB255
1 files changed, 255 insertions, 0 deletions
diff --git a/MIBS/telco-systems/binox/PRVT-TE-PARAM-MIB b/MIBS/telco-systems/binox/PRVT-TE-PARAM-MIB
new file mode 100644
index 0000000..42e5d14
--- /dev/null
+++ b/MIBS/telco-systems/binox/PRVT-TE-PARAM-MIB
@@ -0,0 +1,255 @@
+-- *********************************************************************
+-- **
+-- ** BATM Advanced Communications.
+-- **
+-- *********************************************************************
+-- ** Filename: PRVT-TE-PARAM-MIB.mib
+-- ** Project: T-Metro Switches.
+-- ** Purpose: Private MIB
+-- *********************************************************************
+-- (c) Copyright, 2009, BATM Advanced Communications. All rights reserved.
+-- WARNING:
+--
+-- BY UTILIZING THIS FILE, YOU AGREE TO THE FOLLOWING:
+--
+-- This file is the property of BATM Advanced Communications and contains
+-- proprietary and confidential information. This file is made
+-- available to authorized BATM customers on the express
+-- condition that neither it, nor any of the information contained
+-- therein, shall be disclosed to third parties or be used for any
+-- purpose other than to replace, modify or upgrade firmware and/or
+-- software components of BATM manufactured equipment within the
+-- authorized customer's network, and that such transfer be
+-- completed in accordance with the instructions provided by
+-- BATM. Any other use is strictly prohibited.
+--
+-- EXCEPT AS RESTRICTED BY LAW, OR AS PROVIDED IN BATM'S LIMITED
+-- WARRANTY, THE SOFTWARE PROGRAMS CONTAINED IN THIS FILE ARE
+-- PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED
+-- OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES
+-- OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
+--
+-- IN NO EVENT SHALL BATM BE LIABLE FOR ANY DAMAGES WHATSOEVER
+-- INCLUDING WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS
+-- PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR
+-- OTHER CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE, OR INABILITY
+-- TO USE, THE SOFTWARE CONTAINED IN THIS FILE.
+--
+-- ----------------------------------------------------------------------------
+
+PRVT-TE-PARAM-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ ifIndex
+ FROM IF-MIB
+ mpls
+ FROM PRVT-SWITCH-MIB
+ Integer32, MODULE-IDENTITY, OBJECT-TYPE, Unsigned32
+ FROM SNMPv2-SMI
+ RowStatus, TEXTUAL-CONVENTION
+ FROM SNMPv2-TC;
+
+prvtTeParamMIB MODULE-IDENTITY
+ LAST-UPDATED "201004280000Z"
+ ORGANIZATION
+ "BATM Advanced Communication"
+ CONTACT-INFO
+ "BATM/Telco Systems Support team
+ Email:
+ For North America: techsupport@telco.com
+ For North Europe: support@batm.de, info@batm.de
+ For the rest of the world: techsupport@telco.com"
+ DESCRIPTION
+ "The MIB module for management of TE-params entities."
+ REVISION "201004280000Z"
+ DESCRIPTION
+ "initial version"
+ ::= { mpls 9 }
+
+
+PrvtTeLinkBandwidthSpeed ::= TEXTUAL-CONVENTION
+ DISPLAY-HINT "d"
+ STATUS current
+ DESCRIPTION
+ "Used in combination with PrvtTeLinkBandwidthUnits to specify a link's bandwidth."
+ SYNTAX Unsigned32
+
+PrvtTeLinkBandwidthUnits ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "Used in combination with PrvtTeLinkBandwidthSpeed to specify a link's bandwidth."
+ SYNTAX INTEGER { bps(0), kbps(1), mbps(2), gbps(3) }
+
+prvtTeParamMIBObjects OBJECT IDENTIFIER
+ ::= { prvtTeParamMIB 1 }
+
+prvtTeParamLinkTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PrvtTeParamLinkEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table specifying the parameters of TE links."
+ ::= { prvtTeParamMIBObjects 2 }
+
+prvtTeParamLinkEntry OBJECT-TYPE
+ SYNTAX PrvtTeParamLinkEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in prvtTeParamLinkTable."
+ INDEX { ifIndex }
+ ::= { prvtTeParamLinkTable 1 }
+
+PrvtTeParamLinkEntry ::= SEQUENCE {
+ prvtTeParamLinkRowStatus RowStatus,
+ prvtTeParamLinkMetric Unsigned32,
+ prvtTeParamLinkPhyBandwidthSpeed PrvtTeLinkBandwidthSpeed,
+ prvtTeParamLinkPhyBandwidthUnits PrvtTeLinkBandwidthUnits,
+ prvtTeParamLinkMaxRsvBwSpeed PrvtTeLinkBandwidthSpeed,
+ prvtTeParamLinkMaxRsvBwUnits PrvtTeLinkBandwidthUnits
+}
+
+prvtTeParamLinkRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The RowStatus entry for theprvtTeParamLinkTable."
+ ::= { prvtTeParamLinkEntry 1 }
+
+prvtTeParamLinkMetric OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Traffic engineering metric (TEM) for the TE link.
+ The TEM is derived from its component links.
+ All component links within the TE link must have the same TEM."
+ REFERENCE
+ "Link Bundling in MPLS Traffic Engineering (TE), RFC 4201"
+ ::= { prvtTeParamLinkEntry 2 }
+
+prvtTeParamLinkPhyBandwidthSpeed OBJECT-TYPE
+ SYNTAX PrvtTeLinkBandwidthSpeed
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Used together with the prvtTeParamLinkPhyBandwidthUnits
+ object to specify the physical bandwidth for the TE link."
+ ::= { prvtTeParamLinkEntry 3 }
+
+prvtTeParamLinkPhyBandwidthUnits OBJECT-TYPE
+ SYNTAX PrvtTeLinkBandwidthUnits
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Used together with the prvtTeParamLinkPhyBandwidthSpeed
+ object to specify the physical bandwidth for the TE link."
+ ::= { prvtTeParamLinkEntry 4 }
+
+prvtTeParamLinkMaxRsvBwSpeed OBJECT-TYPE
+ SYNTAX PrvtTeLinkBandwidthSpeed
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Used together with the prvtTeParamLinkMaxRsvBwUnits
+ object to specify the maximum bandwidth for the TE link."
+ ::= { prvtTeParamLinkEntry 5 }
+
+prvtTeParamLinkMaxRsvBwUnits OBJECT-TYPE
+ SYNTAX PrvtTeLinkBandwidthUnits
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Used together with the prvtTeParamLinkMaxRsvBwSpeed
+ object to specify the maximum bandwidth that can be reserved for the TE link."
+ ::= { prvtTeParamLinkEntry 6 }
+
+prvtTeParamLinkAdminGrpTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PrvtTeParamLinkAdminGrpEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table specifying the administrative groups to which a TE link belongs."
+ ::= { prvtTeParamMIBObjects 3 }
+
+prvtTeParamLinkAdminGrpEntry OBJECT-TYPE
+ SYNTAX PrvtTeParamLinkAdminGrpEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in prvtTeParamLinkAdminGrpTable."
+ INDEX { ifIndex, prvtTeParamLinkAdminGrpId }
+ ::= { prvtTeParamLinkAdminGrpTable 1 }
+
+PrvtTeParamLinkAdminGrpEntry ::= SEQUENCE {
+ prvtTeParamLinkAdminGrpId Integer32,
+ prvtTeParamLinkAdminGrpRowStatus RowStatus
+}
+
+prvtTeParamLinkAdminGrpId OBJECT-TYPE
+ SYNTAX Integer32 (1..32)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "ID of the administrative group to which the TE link belongs."
+ ::= { prvtTeParamLinkAdminGrpEntry 1 }
+
+prvtTeParamLinkAdminGrpRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The RowStatus entry for the prvtTeParamLinkAdminGrpTable."
+ ::= { prvtTeParamLinkAdminGrpEntry 2 }
+
+prvtTeParamAdminGroupTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PrvtTeParamAdminGroupEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table storing the identifiers for an administrative group."
+ ::= { prvtTeParamMIBObjects 5 }
+
+prvtTeParamAdminGroupEntry OBJECT-TYPE
+ SYNTAX PrvtTeParamAdminGroupEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "prvtTeParamAdminGroupTable allows the specifying of a group-name to
+ each administrative group. Each group is uniquely identified by its
+ prvtTeParamAdminGroupId."
+ INDEX { prvtTeParamAdminGroupId }
+ ::= { prvtTeParamAdminGroupTable 1 }
+
+PrvtTeParamAdminGroupEntry ::= SEQUENCE {
+ prvtTeParamAdminGroupId Integer32,
+ prvtTeParamAdminGroupRowStatus RowStatus,
+ prvtTeParamAdminGroupName OCTET STRING
+}
+
+prvtTeParamAdminGroupId OBJECT-TYPE
+ SYNTAX Integer32 (1..32)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "ID uniquely identifying an administrative group."
+ ::= { prvtTeParamAdminGroupEntry 1 }
+
+prvtTeParamAdminGroupRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The RowStatus entry for theprvtTeParamAdminGroupTable."
+ ::= { prvtTeParamAdminGroupEntry 2 }
+
+prvtTeParamAdminGroupName OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(1..15))
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The name of the administrative group."
+ ::= { prvtTeParamAdminGroupEntry 3 }
+
+END -- end of module PRVT-TE-PARAM-MIB.