summaryrefslogtreecommitdiff
path: root/MIBS/telco-systems/binox/PRVT-STORM-CTL-MIB
diff options
context:
space:
mode:
authorDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
committerDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
commit98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch)
tree9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/telco-systems/binox/PRVT-STORM-CTL-MIB
downloadmibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.tar.gz
mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.zip
Initial commitHEADmain
Diffstat (limited to 'MIBS/telco-systems/binox/PRVT-STORM-CTL-MIB')
-rw-r--r--MIBS/telco-systems/binox/PRVT-STORM-CTL-MIB168
1 files changed, 168 insertions, 0 deletions
diff --git a/MIBS/telco-systems/binox/PRVT-STORM-CTL-MIB b/MIBS/telco-systems/binox/PRVT-STORM-CTL-MIB
new file mode 100644
index 0000000..4850e9c
--- /dev/null
+++ b/MIBS/telco-systems/binox/PRVT-STORM-CTL-MIB
@@ -0,0 +1,168 @@
+-- *********************************************************************
+-- **
+-- ** BATM Advanced Communications.
+-- **
+-- *********************************************************************
+-- ** Filename: PRVT-STORM-CTL-MIB.mib
+-- ** Project: T-Metro Switches.
+-- ** Purpose: Private MIB
+-- *********************************************************************
+-- (c) Copyright, 2009, BATM Advanced Communications. All rights reserved.
+-- WARNING:
+--
+-- BY UTILIZING THIS FILE, YOU AGREE TO THE FOLLOWING:
+--
+-- This file is the property of BATM Advanced Communications and contains
+-- proprietary and confidential information. This file is made
+-- available to authorized BATM customers on the express
+-- condition that neither it, nor any of the information contained
+-- therein, shall be disclosed to third parties or be used for any
+-- purpose other than to replace, modify or upgrade firmware and/or
+-- software components of BATM manufactured equipment within the
+-- authorized customer's network, and that such transfer be
+-- completed in accordance with the instructions provided by
+-- BATM. Any other use is strictly prohibited.
+--
+-- EXCEPT AS RESTRICTED BY LAW, OR AS PROVIDED IN BATM'S LIMITED
+-- WARRANTY, THE SOFTWARE PROGRAMS CONTAINED IN THIS FILE ARE
+-- PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED
+-- OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES
+-- OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
+--
+-- IN NO EVENT SHALL BATM BE LIABLE FOR ANY DAMAGES WHATSOEVER
+-- INCLUDING WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS
+-- PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR
+-- OTHER CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE, OR INABILITY
+-- TO USE, THE SOFTWARE CONTAINED IN THIS FILE.
+--
+-- ----------------------------------------------------------------------------
+
+PRVT-STORM-CTL-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ ifIndex
+ FROM IF-MIB
+ switch
+ FROM PRVT-SWITCH-MIB
+ MODULE-IDENTITY, OBJECT-TYPE, Unsigned32
+ FROM SNMPv2-SMI
+ RowStatus, TEXTUAL-CONVENTION, TruthValue
+ FROM SNMPv2-TC;
+
+prvtStormCtlMIB MODULE-IDENTITY
+ LAST-UPDATED "201006210000Z"
+ ORGANIZATION
+ "BATM Advanced Communication"
+ CONTACT-INFO
+ "BATM/Telco Systems Support team
+ Email:
+ For North America: techsupport@telco.com
+ For North Europe: support@batm.de, info@batm.de
+ For the rest of the world: techsupport@telco.com"
+ DESCRIPTION
+ "The MIB module for managing storm control."
+ REVISION "201006210000Z"
+ DESCRIPTION
+ "Initial version."
+ ::= { switch 171 }
+
+
+RateThresholdType ::= TEXTUAL-CONVENTION
+ DISPLAY-HINT "d"
+ STATUS current
+ DESCRIPTION
+ "A rate threshold in packets per seconds."
+ SYNTAX Unsigned32
+
+prvtStormCtlMIBObjects OBJECT IDENTIFIER
+ ::= { prvtStormCtlMIB 1 }
+
+prvtStrmCtlPortTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PrvtStrmCtlPortEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of interfaces that have storm control functionality configured."
+ ::= { prvtStormCtlMIBObjects 1 }
+
+prvtStrmCtlPortEntry OBJECT-TYPE
+ SYNTAX PrvtStrmCtlPortEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in prvtStrmCtlPortTable."
+ INDEX { ifIndex }
+ ::= { prvtStrmCtlPortTable 1 }
+
+PrvtStrmCtlPortEntry ::= SEQUENCE {
+ prvtStrmCtlPortRowStatus RowStatus,
+ prvtStrmCtlPortShutdown TruthValue
+}
+
+prvtStrmCtlPortRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The RowStatus for this port."
+ ::= { prvtStrmCtlPortEntry 1 }
+
+prvtStrmCtlPortShutdown OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Set to 'false' to enable storm control functionality on this port."
+ ::= { prvtStrmCtlPortEntry 3 }
+
+prvtStrmCtlPortTrafficTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PrvtStrmCtlPortTrafficEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of traffic-type specific configuration for each interface.
+ Currently, only one traffic type is supported per interface."
+ ::= { prvtStormCtlMIBObjects 3 }
+
+prvtStrmCtlPortTrafficEntry OBJECT-TYPE
+ SYNTAX PrvtStrmCtlPortTrafficEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in prvtStrmCtlPortTrafficTable."
+ INDEX { ifIndex, prvtStrmCtlPortTrafficType }
+ ::= { prvtStrmCtlPortTrafficTable 1 }
+
+PrvtStrmCtlPortTrafficEntry ::= SEQUENCE {
+ prvtStrmCtlPortTrafficType INTEGER,
+ prvtStrmCtlPortTrafficRowStatus RowStatus,
+ prvtStrmCtlPortTrafficThreshold RateThresholdType
+}
+
+prvtStrmCtlPortTrafficType OBJECT-TYPE
+ SYNTAX INTEGER { all(0), unknown(1), multicast(2), broadcast(4) }
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The type of traffic to which this row applies "
+ ::= { prvtStrmCtlPortTrafficEntry 1 }
+
+prvtStrmCtlPortTrafficRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The RowStatus for this traffic type."
+ ::= { prvtStrmCtlPortTrafficEntry 2 }
+
+prvtStrmCtlPortTrafficThreshold OBJECT-TYPE
+ SYNTAX RateThresholdType
+ UNITS "packets-per-second"
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The threshold at which, when exceeded, traffic will undergo
+ storm control action for this port and traffic type."
+ ::= { prvtStrmCtlPortTrafficEntry 3 }
+
+END -- end of module PRVT-STORM-CTL-MIB.