summaryrefslogtreecommitdiff
path: root/MIBS/telco-systems/binos/PRVT-RESILIENT-LINK-MIB
diff options
context:
space:
mode:
authorDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
committerDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
commit98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch)
tree9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/telco-systems/binos/PRVT-RESILIENT-LINK-MIB
downloadmibs-main.tar.gz
mibs-main.zip
Initial commitHEADmain
Diffstat (limited to 'MIBS/telco-systems/binos/PRVT-RESILIENT-LINK-MIB')
-rw-r--r--MIBS/telco-systems/binos/PRVT-RESILIENT-LINK-MIB251
1 files changed, 251 insertions, 0 deletions
diff --git a/MIBS/telco-systems/binos/PRVT-RESILIENT-LINK-MIB b/MIBS/telco-systems/binos/PRVT-RESILIENT-LINK-MIB
new file mode 100644
index 0000000..e77fc1a
--- /dev/null
+++ b/MIBS/telco-systems/binos/PRVT-RESILIENT-LINK-MIB
@@ -0,0 +1,251 @@
+-- *********************************************************************
+-- **
+-- ** BATM Advanced Communications.
+-- **
+-- *********************************************************************
+-- ** Filename: PRVT-RESILIENT-LINK-MIB.mib
+-- ** Project: T - Ethernet and Fast Ethernet IP Switches.
+-- ** Purpose: Private MIB
+-- *********************************************************************
+-- (c) Copyright, 2001, BATM Advanced Communications. All rights reserved.
+-- WARNING:
+--
+-- BY UTILIZING THIS FILE, YOU AGREE TO THE FOLLOWING:
+--
+-- This file is the property of BATM Advanced Communications and contains
+-- proprietary and confidential information. This file is made
+-- available to authorized BATM customers on the express
+-- condition that neither it, nor any of the information contained
+-- therein, shall be disclosed to third parties or be used for any
+-- purpose other than to replace, modify or upgrade firmware and/or
+-- software components of BATM manufactured equipment within the
+-- authorized customer's network, and that such transfer be
+-- completed in accordance with the instructions provided by
+-- BATM. Any other use is strictly prohibited.
+--
+-- EXCEPT AS RESTRICTED BY LAW, OR AS PROVIDED IN BATM'S LIMITED
+-- WARRANTY, THE SOFTWARE PROGRAMS CONTAINED IN THIS FILE ARE
+-- PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED
+-- OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES
+-- OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
+--
+-- IN NO EVENT SHALL BATM BE LIABLE FOR ANY DAMAGES WHATSOEVER
+-- INCLUDING WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS
+-- PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR
+-- OTHER CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE, OR INABILITY
+-- TO USE, THE SOFTWARE CONTAINED IN THIS FILE.
+--
+-- ----------------------------------------------------------------------------
+--
+PRVT-RESILIENT-LINK-MIB DEFINITIONS ::= BEGIN
+ IMPORTS
+ MODULE-IDENTITY, OBJECT-TYPE,
+ NOTIFICATION-TYPE FROM SNMPv2-SMI
+ NOTIFICATION-GROUP FROM SNMPv2-CONF
+ switch FROM PRVT-SWITCH-MIB;
+ -------------------------------------------------------------------------------
+ -- PRIVATE BRANCH PRODUCTS
+ -------------------------------------------------------------------------------
+
+
+ prvtResilientLinkMib MODULE-IDENTITY
+ LAST-UPDATED "200502160000Z"
+ ORGANIZATION "BATM Advanced Communication"
+ CONTACT-INFO
+
+ "BATM/Telco Systems Support team
+ Email:
+ For North America: techsupport@telco.com
+ For North Europe: support@batm.de, info@batm.de
+ For the rest of the world: techsupport@telco.com"
+
+ DESCRIPTION
+ "The Resilient Link MIB module for managing switch or ipSwitch
+ resilient link"
+
+ -- revision history
+ REVISION "200502160000Z"
+ DESCRIPTION
+ "Fixed spelling errors and changed the contact info."
+
+ REVISION "200305060000Z"
+ DESCRIPTION
+ "Move to SMI-V2."
+
+ REVISION "200201280000Z"
+ DESCRIPTION
+ "Initial version."
+ ::= { switch 102 }
+
+
+ -- -----------------------------------------------------------------------------
+ -- resilient link configuration parameters
+ -- -----------------------------------------------------------------------------
+ prvtResilientLinkNotifications OBJECT IDENTIFIER ::= { prvtResilientLinkMib 0 }
+ resilientLinkConfig OBJECT IDENTIFIER ::= { prvtResilientLinkMib 1 }
+ resilientLinkStatus OBJECT IDENTIFIER ::= { prvtResilientLinkMib 2 }
+ prvtResilientLinkConformance OBJECT IDENTIFIER ::= { prvtResilientLinkMib 3 }
+
+ resilientLinkConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ResilientLinkConfigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table contains the resilient link configuration."
+ ::= { resilientLinkConfig 1 }
+
+ resilientLinkConfigEntry OBJECT-TYPE
+ SYNTAX ResilientLinkConfigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "resilientLinkIndex"
+ INDEX { resilientLinkIndex }
+ ::= { resilientLinkConfigTable 1 }
+
+ ResilientLinkConfigEntry ::= SEQUENCE {
+ resilientLinkIndex INTEGER,
+ resilientLinkEnable INTEGER,
+ resilientLinkPort1ifIndex INTEGER,
+ resilientLinkPort2ifIndex INTEGER,
+ resilientLinkPreferredPort INTEGER,
+ resilientLinkActivePort INTEGER
+ }
+
+ resilientLinkIndex OBJECT-TYPE
+ SYNTAX INTEGER(0..256)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object identifies the resilient link"
+ ::= { resilientLinkConfigEntry 1 }
+
+ resilientLinkEnable OBJECT-TYPE
+ SYNTAX INTEGER {
+ enable(1),
+ disable(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object enables or disables the resilient link"
+ ::= { resilientLinkConfigEntry 2 }
+
+ resilientLinkPort1ifIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object identifies the first port belonging to this
+ resilient link; zero means no port is selected"
+ ::= { resilientLinkConfigEntry 3 }
+
+ resilientLinkPort2ifIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object identifies the second port belonging to this
+ resilient link; zero means no port is selected"
+ ::= { resilientLinkConfigEntry 4 }
+
+ resilientLinkPreferredPort OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object identifies the preferred port (1 or 2) in this
+ resilient link; zero means no port is preferred"
+ ::= { resilientLinkConfigEntry 5 }
+
+ resilientLinkActivePort OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object identifies the active port (1 or 2) in this
+ resilient link. Only ports with link up can be configured as active
+ ports."
+ ::= { resilientLinkConfigEntry 6 }
+
+ -- -----------------------------------------------------------------------------
+ -- resilient link status
+ -- -----------------------------------------------------------------------------
+
+ resilientLinkStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ResilientLinkStatusEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table contains the resilient link status."
+ ::= { resilientLinkStatus 2 }
+
+ resilientLinkStatusEntry OBJECT-TYPE
+ SYNTAX ResilientLinkStatusEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "resilientLinkIndex"
+ INDEX { resilientLinkIndex }
+ ::= { resilientLinkStatusTable 1 }
+
+ ResilientLinkStatusEntry ::= SEQUENCE {
+ resilientLinkConnectedPort INTEGER,
+ resilientLinkCurrentActivePort INTEGER
+ }
+
+ resilientLinkConnectedPort OBJECT-TYPE
+ SYNTAX INTEGER {
+ notConnected(1),
+ port1Connected(2),
+ port2Connected(3),
+ port1and2Connected(4)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object shows the connected ports in the resilient link"
+ ::= { resilientLinkStatusEntry 1 }
+
+ resilientLinkCurrentActivePort OBJECT-TYPE
+ SYNTAX INTEGER {
+ noActivePort (1),
+ port1Active (2),
+ port2Active (3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object identifies the active port (1 or 2) in this
+ resilient link. Only ports with link up can be configured as active
+ ports."
+ ::= { resilientLinkStatusEntry 2 }
+
+ -- Traps for use by prvtResilientLinkMib
+
+ resilientLinkStatusChange NOTIFICATION-TYPE
+ OBJECTS { resilientLinkIndex, resilientLinkConnectedPort,
+ resilientLinkCurrentActivePort}
+ STATUS current
+ DESCRIPTION
+ "The resilientLinkStatusChange trap indicates that
+ the sending agent monitor detected a change in the status of the
+ resilient link, identified by resilientLinkIndex."
+ ::= {prvtResilientLinkNotifications 1}
+
+-- *******************************************************************
+-- Conformance Information
+-- *******************************************************************
+
+ prvtResilientLinkMIBGroups OBJECT IDENTIFIER ::= { prvtResilientLinkConformance 2 }
+
+ resilientLinkNotificationGroup NOTIFICATION-GROUP
+ NOTIFICATIONS {
+ resilientLinkStatusChange
+ }
+ STATUS current
+ DESCRIPTION
+ "Private Notification Group."
+ ::= { prvtResilientLinkMIBGroups 3 }
+
+END