summaryrefslogtreecommitdiff
path: root/MIBS/supermicro/SUPERMICRO-SD5-MIB
diff options
context:
space:
mode:
authorDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
committerDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
commit98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch)
tree9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/supermicro/SUPERMICRO-SD5-MIB
downloadmibs-main.tar.gz
mibs-main.zip
Initial commitHEADmain
Diffstat (limited to 'MIBS/supermicro/SUPERMICRO-SD5-MIB')
-rw-r--r--MIBS/supermicro/SUPERMICRO-SD5-MIB2291
1 files changed, 2291 insertions, 0 deletions
diff --git a/MIBS/supermicro/SUPERMICRO-SD5-MIB b/MIBS/supermicro/SUPERMICRO-SD5-MIB
new file mode 100644
index 0000000..3a122bb
--- /dev/null
+++ b/MIBS/supermicro/SUPERMICRO-SD5-MIB
@@ -0,0 +1,2291 @@
+-- *****************************************************************
+-- SUPERMICRO-SSM.mib: Super Micro Enterprise Structure of Management Information
+--
+-- December 21 2017, Software Dept.
+--
+-- Copyright (c) 1993-2019 Super Micro Computer, Inc.
+-- All rights reserved.
+--
+-- *****************************************************************
+
+SUPERMICRO-SD5-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ MODULE-IDENTITY,
+ OBJECT-TYPE,
+ Integer32
+ FROM SNMPv2-SMI
+ DisplayString
+ FROM SNMPv2-TC
+ smSSMInfo
+ FROM SUPERMICRO-SMI;
+
+smSuperDoctor5MIB MODULE-IDENTITY
+ LAST-UPDATED "201307020000Z"
+ ORGANIZATION "Super Micro Computer Inc."
+ CONTACT-INFO
+ " Software Dept.
+
+ Postal: 980 Rock Avenue
+ San Jose, CA 95131
+ USA
+
+ Tel: +1 408 503 8000
+
+ E-mail: SoftLab@supermicro.com"
+ DESCRIPTION
+ "MIB module for sd5 information"
+ ::= { smSSMInfo 1 }
+
+-- sd5
+sd5Table OBJECT-TYPE
+ SYNTAX SEQUENCE OF SD5Entry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of sd5 entries."
+ ::= { smSuperDoctor5MIB 1 }
+
+sd5Entry OBJECT-TYPE
+ SYNTAX SD5Entry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in the sd5 table.
+ Entries cannot be created or deleted via SNMP operations."
+ INDEX { sd5Idx }
+ ::= { sd5Table 1 }
+
+SD5Entry ::=
+ SEQUENCE {
+ sd5Idx Integer32,
+ sd5Version DisplayString,
+ sd5MIBVersion DisplayString
+ }
+
+sd5Idx OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The unique value identifies this sd5."
+ ::= { sd5Entry 1 }
+
+sd5Version OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The version of the sd5."
+ ::= { sd5Entry 2 }
+
+sd5MIBVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The MIB version of the sd5."
+ ::= { sd5Entry 3 }
+
+-- cpu
+cpuTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CpuEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of processor entries."
+ ::= { smSuperDoctor5MIB 2 }
+
+cpuEntry OBJECT-TYPE
+ SYNTAX CpuEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in the processor table.
+ Entries cannot be created or deleted via SNMP operations."
+ INDEX { cpuIndex }
+ ::= { cpuTable 1 }
+
+CpuEntry ::=
+ SEQUENCE {
+ cpuIndex DisplayString,
+ cpuName DisplayString,
+ cpuDescription DisplayString,
+ cpuManufacturer DisplayString,
+ cpuDeviceStatus Integer32,
+ cpuMaxSpeed DisplayString,
+ cpuCurrentSpeed DisplayString,
+ cpuLoadingPercentage DisplayString,
+ cpuCoreEnabled Integer32,
+ cpuCoreCount Integer32,
+ cpuThreadCount Integer32,
+ cpuSocketDesignation DisplayString,
+ cpuDeviceVersion DisplayString,
+ cpuDeviceID DisplayString,
+ cpuID DisplayString
+ }
+
+
+cpuIndex OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The unique value which identifies this processor."
+ ::= { cpuEntry 1 }
+
+cpuName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The name of the processor."
+ ::= { cpuEntry 2 }
+
+cpuDescription OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The description of the processor."
+ ::= { cpuEntry 3 }
+
+cpuManufacturer OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The manufacturer of the processor."
+ ::= { cpuEntry 4 }
+
+cpuDeviceStatus OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The status of the processor.
+ The status depends on the cpu failure check via BIOS.
+ 0: OK
+ 2: Critical "
+ ::= { cpuEntry 5 }
+
+cpuMaxSpeed OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The maximum speed (MHz) of the processor."
+ ::= { cpuEntry 6 }
+
+cpuCurrentSpeed OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current speed (MHz) of the processor."
+ ::= { cpuEntry 7 }
+
+cpuLoadingPercentage OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The loading percentage of the processor."
+ ::= { cpuEntry 9 }
+
+
+cpuCoreEnabled OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The core enabled count of the processor."
+ ::= { cpuEntry 10 }
+
+cpuCoreCount OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The core count of the processor."
+ ::= { cpuEntry 11 }
+
+cpuThreadCount OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The thread count of the processor."
+ ::= { cpuEntry 12 }
+
+
+cpuSocketDesignation OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The socket designation of the processor."
+ ::= { cpuEntry 14 }
+
+cpuDeviceVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The device version of the processor."
+ ::= { cpuEntry 18 }
+
+cpuDeviceID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The device ID of the processor."
+ ::= { cpuEntry 20 }
+
+cpuID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The ID of the processor."
+ ::= { cpuEntry 21 }
+
+
+-- memory
+memTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF MemEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of physical memory entries."
+ ::= { smSuperDoctor5MIB 3 }
+
+memEntry OBJECT-TYPE
+ SYNTAX MemEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in the physical memory table.
+ Entries cannot be created or deleted via SNMP operations."
+ INDEX { memTag }
+ ::= { memTable 1 }
+
+MemEntry ::=
+ SEQUENCE {
+ memTag DisplayString,
+ memDescription DisplayString,
+ memDeviceStatus Integer32,
+ memLabeledBank DisplayString,
+ memDeviceLocator DisplayString,
+ memModel DisplayString,
+ memManufacturer DisplayString,
+ memPartNumber DisplayString,
+ memSerialNumber DisplayString,
+ memCapacity Integer32,
+ memDataWidth DisplayString,
+ memTotalWidth DisplayString,
+ memErrorCount Integer32,
+ memECCErrorCount Integer32,
+ memUECCErrorCount Integer32
+ }
+
+
+memTag OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The tag of the physical memory. The unique value identifies this physical memory."
+ ::= { memEntry 1 }
+
+memDescription OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The description of the physical memory."
+ ::= { memEntry 2 }
+
+memDeviceStatus OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the status of the physical memory.
+ The status depends on the ECC check result on the physical memory.
+ 0: OK
+ 2: Critical "
+ ::= { memEntry 3 }
+
+memLabeledBank OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The labeled bank of the physical memory."
+ ::= { memEntry 4 }
+
+memDeviceLocator OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The device locator of the physical memory."
+ ::= { memEntry 5 }
+
+memModel OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The model name of the physical memory."
+ ::= { memEntry 7 }
+
+memManufacturer OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The manufacturer's name of the physical memory."
+ ::= { memEntry 8 }
+
+memPartNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The part number of the physical memory."
+ ::= { memEntry 9 }
+
+memSerialNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The serial number of the physical memory."
+ ::= { memEntry 10 }
+
+memCapacity OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The capacity of the physical memory. (Unit: MB)"
+ ::= { memEntry 11 }
+
+memDataWidth OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The data width of the physical memory. (Unit: bit)"
+ ::= { memEntry 12 }
+
+memTotalWidth OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total width of the physical memory. (Unit: bit)"
+ ::= { memEntry 13 }
+
+memErrorCount OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The error count of the physical memory.
+ It's the summary of the ECC error count and UECC error count."
+ ::= { memEntry 15 }
+
+memECCErrorCount OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The ECC error count of the physical memory."
+ ::= { memEntry 16 }
+
+memUECCErrorCount OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The UECC error count of the physical memory."
+ ::= { memEntry 17 }
+
+-- disk
+diskTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF DiskEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of physical disk entries."
+ ::= { smSuperDoctor5MIB 4 }
+
+diskEntry OBJECT-TYPE
+ SYNTAX DiskEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in the physical disk table.
+ Entries cannot be created or deleted via SNMP operations."
+ INDEX { diskName }
+ ::= { diskTable 1 }
+
+DiskEntry ::=
+ SEQUENCE {
+ diskSerialNumber DisplayString,
+ diskName DisplayString,
+ diskVendor DisplayString,
+ diskSmartStatus Integer32,
+ diskModel DisplayString,
+ diskSize Integer32,
+ diskMediaType DisplayString,
+ diskInterfaceType DisplayString,
+ diskController DisplayString,
+ diskSlotID DisplayString
+ }
+
+diskSerialNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The serial number of the disk."
+ ::= { diskEntry 1 }
+
+diskName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The name of the disk. The unique value identifies this disk."
+ ::= { diskEntry 2 }
+
+diskVendor OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The vendor name of the disk."
+ ::= { diskEntry 3 }
+
+diskSmartStatus OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the status of the disk.
+ The status depends on the SMART check result on the disk.
+ 0: OK
+ 2: Critical "
+ ::= { diskEntry 4 }
+
+
+diskModel OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The model of the disk."
+ ::= { diskEntry 5 }
+
+diskSize OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The size of the disk. (Unit: MB)"
+ ::= { diskEntry 6 }
+
+
+diskMediaType OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The media type of the disk includes
+ External hard disk media
+ Removable media other than floppy
+ Fixed hard disk media and Unknown format"
+ ::= { diskEntry 8 }
+
+diskInterfaceType OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The disk interface types includes IDE, HDC, USB, and SCSI."
+ ::= { diskEntry 9 }
+
+diskController OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The controller name of the disk."
+ ::= { diskEntry 10 }
+
+diskSlotID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The Slot ID of the disk."
+ ::= { diskEntry 11 }
+
+
+-- system bios
+sysBIOSTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SysBIOSEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of System BIOS entries."
+ ::= { smSuperDoctor5MIB 5 }
+
+sysBIOSEntry OBJECT-TYPE
+ SYNTAX SysBIOSEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in the System BIOS table.
+ Entries cannot be created or deleted via SNMP operations."
+ INDEX { sysBIOSIndex }
+ ::= { sysBIOSTable 1 }
+
+SysBIOSEntry ::=
+ SEQUENCE {
+ sysBIOSIndex Integer32,
+ sysBIOSReleaseDate DisplayString,
+ sysBIOSVersion DisplayString,
+ sysBIOSManufacturer DisplayString
+ }
+
+sysBIOSIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The unique value identifies this BIOS."
+ ::= { sysBIOSEntry 1 }
+
+sysBIOSReleaseDate OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The release date of BIOS."
+ ::= { sysBIOSEntry 7 }
+
+sysBIOSVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The version of BIOS."
+ ::= { sysBIOSEntry 8 }
+
+sysBIOSManufacturer OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The manufacturer's name of BIOS."
+ ::= { sysBIOSEntry 11 }
+
+-- baseboard
+mbTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF MBEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of baseboard entries."
+ ::= { smSuperDoctor5MIB 6 }
+
+mbEntry OBJECT-TYPE
+ SYNTAX MBEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in the baseboard table.
+ Entries cannot be created or deleted via SNMP operations."
+ INDEX { mbIndex }
+ ::= { mbTable 1 }
+
+MBEntry ::=
+ SEQUENCE {
+ mbIndex Integer32,
+ mbManufacturer DisplayString,
+ mbProductName DisplayString,
+ mbVersionName DisplayString,
+ mbAssetTag DisplayString,
+ mbSerialNumber DisplayString
+ }
+
+mbIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The unique value identifies this baseboard."
+ ::= { mbEntry 1 }
+
+mbManufacturer OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The manufacturer's name of the baseboard."
+ ::= { mbEntry 10 }
+
+mbProductName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The product name of the baseboard."
+ ::= { mbEntry 11 }
+
+mbVersionName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The version of the baseboard."
+ ::= { mbEntry 12 }
+
+mbAssetTag OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The asset tag of the baseboard."
+ ::= { mbEntry 15 }
+
+mbSerialNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The serial number of the baseboard."
+ ::= { mbEntry 16 }
+
+-- operation system
+osTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF OSEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of operation system entries."
+ ::= { smSuperDoctor5MIB 7 }
+
+osEntry OBJECT-TYPE
+ SYNTAX OSEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in the operation system table.
+ Entries cannot be created or deleted via SNMP operations."
+ INDEX { osIndex }
+ ::= { osTable 1 }
+
+OSEntry ::=
+ SEQUENCE {
+ osIndex Integer32,
+ osName DisplayString,
+ osVersion DisplayString,
+ osManufacturer DisplayString,
+ osSerialNumber DisplayString,
+ osCSDVersion DisplayString
+ }
+
+
+osIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The unique value identifies this Operation System."
+ ::= { osEntry 1 }
+
+osName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The name of the Operation System."
+ ::= { osEntry 6 }
+
+osVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The version of the operation system."
+ ::= { osEntry 7 }
+
+osManufacturer OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The manufacturer's name of the Operation System."
+ ::= { osEntry 8 }
+
+osSerialNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The serial number of the operation system."
+ ::= { osEntry 9 }
+
+osCSDVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The CSD version of the operation system."
+ ::= { osEntry 10 }
+
+
+-- dmi event logs
+
+dmiLogTable OBJECT IDENTIFIER ::= { smSuperDoctor5MIB 8 }
+
+ceccLogTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CeccLogEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of operation system entries."
+ ::= { dmiLogTable 1 }
+
+ceccLogEntry OBJECT-TYPE
+ SYNTAX CeccLogEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in the operation system table.
+ Entries cannot be created or deleted via SNMP operations."
+ INDEX { ceccLogIndex }
+ ::= { ceccLogTable 1 }
+
+CeccLogEntry ::=
+ SEQUENCE {
+ ceccLogDatetime DisplayString,
+ ceccLogInfo DisplayString,
+ ceccLogIndex Integer32
+ }
+
+ceccLogDatetime OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The CSD version of the operation system."
+ ::= { ceccLogEntry 1 }
+
+ceccLogInfo OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The CSD version of the operation system."
+ ::= { ceccLogEntry 2 }
+
+ceccLogIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The CSD version of the operation system."
+ ::= { ceccLogEntry 10 }
+
+
+ueccLogTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF UeccLogEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of operation system entries."
+ ::= { dmiLogTable 2 }
+
+ueccLogEntry OBJECT-TYPE
+ SYNTAX UeccLogEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in the operation system table.
+ Entries cannot be created or deleted via SNMP operations."
+ INDEX { ceccLogIndex }
+ ::= { ueccLogTable 1 }
+
+UeccLogEntry ::=
+ SEQUENCE {
+ ueccLogDatetime DisplayString,
+ ueccLogInfo DisplayString,
+ ueccLogIndex Integer32
+ }
+
+ueccLogDatetime OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The CSD version of the operation system."
+ ::= { ueccLogEntry 1 }
+
+ueccLogInfo OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The CSD version of the operation system."
+ ::= { ueccLogEntry 2 }
+
+ueccLogIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The CSD version of the operation system."
+ ::= { ueccLogEntry 10 }
+
+postLogTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PostLogEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of operation system entries."
+ ::= { dmiLogTable 8 }
+
+postLogEntry OBJECT-TYPE
+ SYNTAX PostLogEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in the operation system table.
+ Entries cannot be created or deleted via SNMP operations."
+ INDEX { postLogIndex }
+ ::= { postLogTable 1 }
+
+PostLogEntry ::=
+ SEQUENCE {
+ postLogDatetime DisplayString,
+ postLogInfo DisplayString,
+ postLogIndex Integer32
+ }
+
+postLogDatetime OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The CSD version of the operation system."
+ ::= { postLogEntry 1 }
+
+postLogInfo OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The CSD version of the operation system."
+ ::= { postLogEntry 2 }
+
+postLogIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The CSD version of the operation system."
+ ::= { postLogEntry 10 }
+
+
+cpuLogTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CpuLogEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of operation system entries."
+ ::= { dmiLogTable 11 }
+
+cpuLogEntry OBJECT-TYPE
+ SYNTAX CpuLogEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in the operation system table.
+ Entries cannot be created or deleted via SNMP operations."
+ INDEX { cpuLogIndex }
+ ::= { cpuLogTable 1 }
+
+CpuLogEntry ::=
+ SEQUENCE {
+ cpuLogDatetime DisplayString,
+ cpuLogInfo DisplayString,
+ cpuLogIndex Integer32
+ }
+
+cpuLogDatetime OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The CSD version of the operation system."
+ ::= { cpuLogEntry 1 }
+
+cpuLogInfo OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The CSD version of the operation system."
+ ::= { cpuLogEntry 2 }
+
+cpuLogIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The CSD version of the operation system."
+ ::= { cpuLogEntry 10 }
+
+
+-- RAID Controller
+raidAdapterTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RaidAdapterEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of raid controller entries."
+ ::= { smSuperDoctor5MIB 9 }
+
+raidAdapterEntry OBJECT-TYPE
+ SYNTAX RaidAdapterEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in the raid controller table.
+ Entries cannot be created or deleted via SNMP operations."
+ INDEX { raidAdapterIndex }
+ ::= { raidAdapterTable 1 }
+
+RaidAdapterEntry ::=
+ SEQUENCE {
+ raidAdapterIndex Integer32,
+ raidAdapterGroup DisplayString,
+ raidAdapterId DisplayString,
+ raidAdapterProductName DisplayString,
+ raidAdapterSerialNumber DisplayString,
+ raidAdapterFWPackageBuild DisplayString,
+ raidAdapterFWVersion DisplayString,
+ raidAdapterBIOSVersion DisplayString,
+ raidAdapterVendorId DisplayString,
+ raidAdapterDeviceId DisplayString,
+ raidAdapterSubVendorId DisplayString,
+ raidAdapterSubDeviceId DisplayString,
+ raidIsBBUAbsent DisplayString,
+ raidIsBBUAbsentIgnored DisplayString,
+ raidAdapterAllinoneStatus Integer32,
+ raidAdapterAllinoneMsg DisplayString
+ }
+
+
+raidAdapterIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Raid controller index. The unique value which identifies this raid controller."
+ ::= { raidAdapterEntry 1 }
+
+raidAdapterGroup OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The group of the raid controller. Values:
+ LSI-MegaRAID
+ LSI-Fusion-MPT
+ "
+ ::= { raidAdapterEntry 2 }
+
+
+raidAdapterId OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The id of the raid controller. The id is unique in one adapter group."
+ ::= { raidAdapterEntry 3 }
+
+raidAdapterProductName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The product name of the raid controller."
+ ::= { raidAdapterEntry 4 }
+
+raidAdapterSerialNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The serial number of the raid controller."
+ ::= { raidAdapterEntry 5 }
+
+raidAdapterFWPackageBuild OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The build number of the firmware package of the raid controller."
+ ::= { raidAdapterEntry 6 }
+
+raidAdapterFWVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The firmware version of the raid controller."
+ ::= { raidAdapterEntry 7 }
+
+raidAdapterBIOSVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The bios version of the raid controller."
+ ::= { raidAdapterEntry 8 }
+
+raidAdapterVendorId OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The PCI vendor id of the raid controller."
+ ::= { raidAdapterEntry 9 }
+
+raidAdapterDeviceId OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The PCI device id of the raid controller."
+ ::= { raidAdapterEntry 10 }
+
+raidAdapterSubVendorId OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The PCI sub-vendor id of the raid controller."
+ ::= { raidAdapterEntry 11 }
+
+raidAdapterSubDeviceId OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The PCI sub-device id of the raid controller."
+ ::= { raidAdapterEntry 12 }
+
+
+raidIsBBUAbsent OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Is the BBU absent or present?
+ Values: Absent, Present."
+ ::= { raidAdapterEntry 13 }
+
+raidIsBBUAbsentIgnored OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Does the raid controller ignore the absent BBU?
+ Values: YES, NO.
+ If the value is No then the absent BBU will affect the all-in-one status of the raid controller."
+ ::= { raidAdapterEntry 14 }
+
+raidAdapterAllinoneStatus OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the status of the raid controller. Values:
+ 0: OK
+ 1: Warning
+ 2: Critical
+ "
+ ::= { raidAdapterEntry 15 }
+
+
+raidAdapterAllinoneMsg OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The status message of the raid controller."
+ ::= { raidAdapterEntry 16 }
+
+
+-- RAID BBU
+raidBBUTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RaidBBUEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of raid BBU entries."
+ ::= { smSuperDoctor5MIB 10 }
+
+raidBBUEntry OBJECT-TYPE
+ SYNTAX RaidBBUEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in the raid BBU table.
+ Entries cannot be created or deleted via SNMP operations."
+ INDEX { raidBBUIndex }
+ ::= { raidBBUTable 1 }
+
+RaidBBUEntry ::=
+ SEQUENCE {
+ raidBBUIndex Integer32,
+ raidAdapterGroup-BBU DisplayString,
+ raidAdapterId-BBU DisplayString,
+ raidBBUStatus DisplayString,
+ raidBBUAllinoneStatus Integer32,
+ raidBBUAllinoneMsg DisplayString
+ }
+
+
+raidBBUIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Raid BBU index.
+ The unique value which identifies this raid BBU."
+ ::= { raidBBUEntry 1 }
+
+raidAdapterGroup-BBU OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The group of the raid controller. Values:
+ LSI-MegaRAID
+ LSI-Fusion-MPT
+ "
+ ::= { raidBBUEntry 2 }
+
+
+raidAdapterId-BBU OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The id of the raid controller. The id is unique in one adapter group."
+ ::= { raidBBUEntry 3 }
+
+
+raidBBUStatus OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the status of the properties of the BBU.
+ Values: Passed, Failed."
+ ::= { raidBBUEntry 8 }
+
+
+raidBBUAllinoneStatus OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the status of the BBU. Values:
+ 0: OK
+ 1: Warning
+ 2: Critical
+ "
+ ::= { raidBBUEntry 9}
+
+
+raidBBUAllinoneMsg OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The status message of the BBU."
+ ::= { raidBBUEntry 10}
+
+
+-- RAID VD
+raidVDTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RaidVDEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of virtual drive entries."
+ ::= { smSuperDoctor5MIB 11 }
+
+raidVDEntry OBJECT-TYPE
+ SYNTAX RaidVDEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in the virtual drive table.
+ Entries cannot be created or deleted via SNMP operations."
+ INDEX { raidVDIndex }
+ ::= { raidVDTable 1 }
+
+RaidVDEntry ::=
+ SEQUENCE {
+ raidVDIndex Integer32,
+ raidAdapterGroup-VD DisplayString,
+ raidAdapterId-VD DisplayString,
+ raidDiskGroupId DisplayString,
+ raidVDId DisplayString,
+ raidVDTargetId DisplayString,
+ raidVDName DisplayString,
+ raidVDRaidLevel DisplayString,
+ raidVDSize DisplayString,
+ raidVDMirrorDataSize DisplayString,
+ raidVDStripSize DisplayString,
+ raidVDNumDrives DisplayString,
+ raidVDSpanDepth DisplayString,
+ raidVDDefaultCachePolicy DisplayString,
+ raidVDCurrentCachePolicy DisplayString,
+ raidVDDefaultAccessPolicy DisplayString,
+ raidVDCurrentAccessPolicy DisplayString,
+ raidVDDiskCachePolicy DisplayString,
+ raidVDEncryptionType DisplayString,
+ raidVDDefaultPSPolicy DisplayString,
+ raidVDCurrentPSPolicy DisplayString,
+ raidVDCanSpinUpIn1Min DisplayString,
+ raidVDSupportT10Power DisplayString,
+ raidVDSupportsMaxPS DisplayString,
+ raidVDBadBlocksExist DisplayString,
+ raidVDCached DisplayString,
+ raidVDState DisplayString,
+ raidVDAllinoneStatus Integer32,
+ raidVDAllinoneMsg DisplayString
+
+ }
+
+
+raidVDIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Raid virtual drive index.
+ The unique value which identifies this raid virtual drive."
+ ::= { raidVDEntry 1 }
+
+raidAdapterGroup-VD OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The group of the raid controller. Values:
+ LSI-MegaRAID
+ LSI-Fusion-MPT
+ "
+ ::= { raidVDEntry 2 }
+
+
+raidAdapterId-VD OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The id of the raid controller. The id is unique in one adapter group."
+ ::= { raidVDEntry 3 }
+
+
+raidDiskGroupId OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The disk group id of the virtual drive."
+ ::= { raidVDEntry 4 }
+
+
+raidVDId OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The id of the virtual drive."
+ ::= { raidVDEntry 5 }
+
+
+raidVDTargetId OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The target id of the virtual drive."
+ ::= { raidVDEntry 6 }
+
+
+raidVDName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The name of the virtual drive."
+ ::= { raidVDEntry 7 }
+
+
+raidVDRaidLevel OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The raid level of the virtual drive."
+ ::= { raidVDEntry 8 }
+
+
+raidVDSize OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The size of the virtual drive."
+ ::= { raidVDEntry 9 }
+
+
+raidVDMirrorDataSize OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The mirror data size of the virtual drive."
+ ::= { raidVDEntry 10 }
+
+
+raidVDStripSize OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The stripe size of the virtual drive."
+ ::= { raidVDEntry 11 }
+
+
+raidVDNumDrives OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of physical drives of the virtual drive."
+ ::= { raidVDEntry 12 }
+
+
+raidVDSpanDepth OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The span depth of the virtual drive."
+ ::= { raidVDEntry 13 }
+
+
+raidVDDefaultCachePolicy OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The default cache policy of the virtual drive."
+ ::= { raidVDEntry 14 }
+
+
+raidVDCurrentCachePolicy OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current cache policy of the virtual drive."
+ ::= { raidVDEntry 15 }
+
+
+raidVDDefaultAccessPolicy OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The default access policy of the virtual drive."
+ ::= { raidVDEntry 16 }
+
+raidVDCurrentAccessPolicy OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current access policy of the virtual drive."
+ ::= { raidVDEntry 17 }
+
+
+raidVDDiskCachePolicy OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The disk cache policy of the virtual drive."
+ ::= { raidVDEntry 18 }
+
+
+raidVDEncryptionType OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The encryption type of the virtual drive."
+ ::= { raidVDEntry 19 }
+
+
+raidVDDefaultPSPolicy OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The default power savings policy of the virtual drive."
+ ::= { raidVDEntry 20 }
+
+
+raidVDCurrentPSPolicy OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The default current savings policy of the virtual drive."
+ ::= { raidVDEntry 21 }
+
+
+raidVDCanSpinUpIn1Min OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Can the physical drive spin up in 1 minute?"
+ ::= { raidVDEntry 22 }
+
+
+raidVDSupportT10Power OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Does the VD have drives that support T10 power conditions?"
+ ::= { raidVDEntry 23 }
+
+
+raidVDSupportsMaxPS OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Does the VD's IO profile supports MAX power savings with cached writes?"
+ ::= { raidVDEntry 24 }
+
+raidVDBadBlocksExist OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Does the virtual drive have bad blocks?"
+ ::= { raidVDEntry 25 }
+
+
+raidVDCached OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Is the virtual drive cached?"
+ ::= { raidVDEntry 26 }
+
+
+raidVDState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The state of the virtual drive. Values:
+ Offline, Partially-degraded, Degraded, Optimal.
+ "
+ ::= { raidVDEntry 27 }
+
+
+raidVDAllinoneStatus OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the status of the virtual drive. Values:
+ 0: OK
+ 1: Warning
+ 2: Critical
+ "
+ ::= { raidVDEntry 28}
+
+
+raidVDAllinoneMsg OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The status message of the virtual drive."
+ ::= { raidVDEntry 29}
+
+-- RAID PD
+raidPDTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RaidPDEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of physical drive entries."
+ ::= { smSuperDoctor5MIB 12 }
+
+raidPDEntry OBJECT-TYPE
+ SYNTAX RaidPDEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in the physical drive table.
+ Entries cannot be created or deleted via SNMP operations."
+ INDEX { raidPDIndex }
+ ::= { raidPDTable 1 }
+
+RaidPDEntry ::=
+ SEQUENCE {
+ raidPDIndex Integer32,
+ raidAdapterGroup-PD DisplayString,
+ raidAdapterId-PD DisplayString,
+ raidDiskGroupId-PD DisplayString,
+ raidPDSlotNumber DisplayString,
+ raidPDFirmwareState DisplayString,
+ raidPDMediaErrorCount DisplayString,
+ raidPDOtherErrorCount DisplayString,
+ raidPDPredFailCount DisplayString,
+ raidPDLastPredFailEventSeqNo DisplayString,
+ raidPDRawSize DisplayString,
+ raidPDDeviceFwLevel DisplayString,
+ raidPDInquiryData DisplayString,
+ raidPDDeviceSpeed DisplayString,
+ raidPDLinkSpeed DisplayString,
+ raidPDMediaType DisplayString,
+ raidPDWriteCache DisplayString,
+ raidPDNCQSetting DisplayString,
+ raidPDPort0Linkspeed DisplayString,
+ raidPDPort0Status DisplayString,
+ raidPDPort1Linkspeed DisplayString,
+ raidPDPort1Status DisplayString,
+ raidPDEnclosureDeviceID DisplayString,
+ raidPDOpProgress DisplayString,
+ raidPDSpan DisplayString,
+ raidPDAllinoneStatus Integer32,
+ raidPDAllinoneMsg DisplayString,
+ raidPDModel DisplayString,
+ raidPDSerialNumber DisplayString,
+ raidPDFirmwareRevision DisplayString
+
+ }
+
+
+raidPDIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Raid physical drive index.
+ The unique value which identifies this raid physical drive."
+ ::= { raidPDEntry 1 }
+
+raidAdapterGroup-PD OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The group of the raid controller. Values:
+ LSI-MegaRAID
+ LSI-Fusion-MPT
+ "
+ ::= { raidPDEntry 2 }
+
+
+raidAdapterId-PD OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The id of the raid controller. The id is unique in one adapter group."
+ ::= { raidPDEntry 3 }
+
+
+raidDiskGroupId-PD OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The disk group id of the virtual drive."
+ ::= { raidPDEntry 4 }
+
+raidPDSlotNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The slot number of the physical drive."
+ ::= { raidPDEntry 5 }
+
+
+raidPDFirmwareState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The firmware state of the physical drive. Values:
+ unconfigured-good, unconfigured-bad, hot-spare, offline, failed, rebuild, online, and copyback"
+ ::= { raidPDEntry 6 }
+
+
+raidPDMediaErrorCount OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The media error count of the physical drive."
+ ::= { raidPDEntry 7 }
+
+
+raidPDOtherErrorCount OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The other error count of the physical drive."
+ ::= { raidPDEntry 8 }
+
+
+raidPDPredFailCount OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The predictive failure count of the physical drive."
+ ::= { raidPDEntry 9 }
+
+raidPDLastPredFailEventSeqNo OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The last predictive failure event sequence number of the physical drive."
+ ::= { raidPDEntry 10 }
+
+raidPDRawSize OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The raw size of the physical drive."
+ ::= { raidPDEntry 11 }
+
+raidPDDeviceFwLevel OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The device firmware level of the physical drive."
+ ::= { raidPDEntry 12 }
+
+raidPDInquiryData OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The inquiry data of the physical drive."
+ ::= { raidPDEntry 13 }
+
+raidPDDeviceSpeed OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The device speed of the physical drive."
+ ::= { raidPDEntry 14 }
+
+raidPDLinkSpeed OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The link speed of the physical drive."
+ ::= { raidPDEntry 15 }
+
+raidPDMediaType OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The media type of the physical drive."
+ ::= { raidPDEntry 16 }
+
+raidPDWriteCache OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The write cache of the physical drive."
+ ::= { raidPDEntry 17 }
+
+raidPDNCQSetting OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The NCQ setting of the physical drive."
+ ::= { raidPDEntry 18 }
+
+raidPDPort0Linkspeed OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The link speed of port 0 of the physical drive."
+ ::= { raidPDEntry 19 }
+
+raidPDPort0Status OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The status of port 0 of the physical drive."
+ ::= { raidPDEntry 20 }
+
+raidPDPort1Linkspeed OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The link speed of port 1 of the physical drive."
+ ::= { raidPDEntry 21 }
+
+raidPDPort1Status OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The status of port 1 of the physical drive."
+ ::= { raidPDEntry 22 }
+
+raidPDEnclosureDeviceID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The enclosure id of the physical drive."
+ ::= { raidPDEntry 23 }
+
+raidPDOpProgress OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The operation progress of the physical drive."
+ ::= { raidPDEntry 24 }
+
+raidPDSpan OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The span of the physical drive."
+ ::= { raidPDEntry 25 }
+
+raidPDAllinoneStatus OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the status of the physical drive. Values:
+ 0: OK
+ 1: Warning
+ 2: Critical
+ "
+ ::= { raidPDEntry 26}
+
+
+raidPDAllinoneMsg OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The status message of the physical drive."
+ ::= { raidPDEntry 27}
+
+
+raidPDModel OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The model of the physical drive."
+ ::= { raidPDEntry 28}
+
+
+raidPDSerialNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The serial number of the physical drive."
+ ::= { raidPDEntry 29}
+
+
+raidPDFirmwareRevision OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The firmware revision of the physical drive."
+ ::= { raidPDEntry 30}
+
+
+smSD5TrapMIB OBJECT IDENTIFIER ::= { smSSMInfo 3 }
+
+trapFanNormal TRAP-TYPE
+ ENTERPRISE smSD5TrapMIB
+ DESCRIPTION "Fan Speed has returned to Normal"
+
+ --#TYPE "FAN Event"
+ --#SUMMARY "Fan Speed has returned to Normal"
+ --#ARGUMENTS {}
+ --#SEVERITY INFORMATIONAL
+
+ ::= 101
+
+trapFanWarning TRAP-TYPE
+ ENTERPRISE smSD5TrapMIB
+ DESCRIPTION "Fan Speed is Warning"
+
+ --#TYPE "FAN Event"
+ --#SUMMARY "Fan Speed is Warning"
+ --#ARGUMENTS {}
+ --#SEVERITY WARNING
+
+ ::= 102
+
+trapFanCritical TRAP-TYPE
+ ENTERPRISE smSD5TrapMIB
+ DESCRIPTION "Fan Speed is Critical"
+
+ --#TYPE "FAN Event"
+ --#SUMMARY "Fan Speed is Critical"
+ --#ARGUMENTS {}
+ --#SEVERITY CRITICAL
+
+ ::= 103
+
+trapVoltageNormal TRAP-TYPE
+ ENTERPRISE smSD5TrapMIB
+ DESCRIPTION "Voltage has returned to Normal"
+
+ --#TYPE "Voltage Event"
+ --#SUMMARY "Voltage has returned to Normal"
+ --#ARGUMENTS {}
+ --#SEVERITY INFORMATIONAL
+
+ ::= 201
+
+trapVoltageWarning TRAP-TYPE
+ ENTERPRISE smSD5TrapMIB
+ DESCRIPTION "Voltage is Warning"
+
+ --#TYPE "Voltage Event"
+ --#SUMMARY "Voltage is Warning"
+ --#ARGUMENTS {}
+ --#SEVERITY WARNING
+
+ ::= 202
+
+trapVoltageCritical TRAP-TYPE
+ ENTERPRISE smSD5TrapMIB
+ DESCRIPTION "Voltage is Critical"
+
+ --#TYPE "Voltage Event"
+ --#SUMMARY "Voltage is Critical"
+ --#ARGUMENTS {}
+ --#SEVERITY CRITICAL
+
+ ::= 203
+
+trapTemperatureNormal TRAP-TYPE
+ ENTERPRISE smSD5TrapMIB
+ DESCRIPTION "Temperature has returned to Normal"
+
+ --#TYPE "Temperature Event"
+ --#SUMMARY "Temperature has returned to Normal"
+ --#ARGUMENTS {}
+ --#SEVERITY INFORMATIONAL
+
+ ::= 301
+
+trapTemperatureWarning TRAP-TYPE
+ ENTERPRISE smSD5TrapMIB
+ DESCRIPTION "Temperature is Warning"
+
+ --#TYPE "Temperature Event"
+ --#SUMMARY "Temperature is Warning"
+ --#ARGUMENTS {}
+ --#SEVERITY WARNING
+
+ ::= 302
+
+trapTemperatureCritical TRAP-TYPE
+ ENTERPRISE smSD5TrapMIB
+ DESCRIPTION "Temperature is Critical"
+
+ --#TYPE "Temperature Event"
+ --#SUMMARY "Temperature is Critical"
+ --#ARGUMENTS {}
+ --#SEVERITY CRITICAL
+
+ ::= 303
+
+trapChassisIntrusionCleared TRAP-TYPE
+ ENTERPRISE smSD5TrapMIB
+ DESCRIPTION "Chassis Intrusion has cleared"
+
+ --#TYPE "Chassis Intrusion Event"
+ --#SUMMARY "Chassis Intrusion has cleared"
+ --#ARGUMENTS {}
+ --#SEVERITY INFORMATIONAL
+
+ ::= 401
+
+trapChassisIntrusion TRAP-TYPE
+ ENTERPRISE smSD5TrapMIB
+ DESCRIPTION "Chassis Intrusion has triggered"
+
+ --#TYPE "Chassis Intrusion Event"
+ --#SUMMARY "Chassis Intrusion has triggered"
+ --#ARGUMENTS {}
+ --#SEVERITY CRITICAL
+
+ ::= 403
+
+trapStorageSMARTCheckNormal TRAP-TYPE
+ ENTERPRISE smSD5TrapMIB
+ DESCRIPTION "Storage SMART Check has returned to Normal"
+
+ --#TYPE "Storage SMART Check Event"
+ --#SUMMARY "Storage SMART Check has returned to Normal"
+ --#ARGUMENTS {}
+ --#SEVERITY INFORMATIONAL
+
+ ::= 601
+
+trapStorageSMARTCheckWarning TRAP-TYPE
+ ENTERPRISE smSD5TrapMIB
+ DESCRIPTION "Storage SMART Check is Warning"
+
+ --#TYPE "Storage SMART Check Event"
+ --#SUMMARY "Storage SMART Check is Warning"
+ --#ARGUMENTS {}
+ --#SEVERITY WARNING
+
+ ::= 602
+
+trapStorageSMARTCheckCritical TRAP-TYPE
+ ENTERPRISE smSD5TrapMIB
+ DESCRIPTION "Storage SMART Check is Critical"
+
+ --#TYPE "Storage SMART Check Event"
+ --#SUMMARY "Storage SMART Check is Critical"
+ --#ARGUMENTS {}
+ --#SEVERITY CRITICAL
+
+ ::= 603
+
+trapPowerSupplyNormal TRAP-TYPE
+ ENTERPRISE smSD5TrapMIB
+ DESCRIPTION "Power Supply has returned to Normal"
+
+ --#TYPE "Power Supply Event"
+ --#SUMMARY "Power Supply has returned to Normal"
+ --#ARGUMENTS {}
+ --#SEVERITY INFORMATIONAL
+
+ ::= 701
+
+trapPowerSupplyWarning TRAP-TYPE
+ ENTERPRISE smSD5TrapMIB
+ DESCRIPTION "Power Supply is Warning"
+
+ --#TYPE "Power Supply Event"
+ --#SUMMARY "Power Supply is Warning"
+ --#ARGUMENTS {}
+ --#SEVERITY WARNING
+
+ ::= 702
+
+trapPowerSupplyCritical TRAP-TYPE
+ ENTERPRISE smSD5TrapMIB
+ DESCRIPTION "Power Supply is Critical"
+
+ --#TYPE "Power Supply Event"
+ --#SUMMARY "Power Supply is Critical"
+ --#ARGUMENTS {}
+ --#SEVERITY CRITICAL
+
+ ::= 703
+
+trapMemoryCeccNormal TRAP-TYPE
+ ENTERPRISE smSD5TrapMIB
+ DESCRIPTION "Memory CECC has returned to Normal"
+
+ --#TYPE "Memory CECC Event"
+ --#SUMMARY "Memory CECC has returned to Normal"
+ --#ARGUMENTS {}
+ --#SEVERITY INFORMATIONAL
+
+ ::= 801
+
+trapMemoryCeccWarning TRAP-TYPE
+ ENTERPRISE smSD5TrapMIB
+ DESCRIPTION "Memory CECC is Warning"
+
+ --#TYPE "Memory CECC Event"
+ --#SUMMARY "Memory CECC is Warning"
+ --#ARGUMENTS {}
+ --#SEVERITY WARNING
+
+ ::= 802
+
+trapMemoryCeccCritical TRAP-TYPE
+ ENTERPRISE smSD5TrapMIB
+ DESCRIPTION "Memory CECC is Critical"
+
+ --#TYPE "Memory CECC Event"
+ --#SUMMARY "Memory CECC is Critical"
+ --#ARGUMENTS {}
+ --#SEVERITY CRITICAL
+
+ ::= 803
+
+trapMemoryUeccNormal TRAP-TYPE
+ ENTERPRISE smSD5TrapMIB
+ DESCRIPTION "Memory UECC has returned to Normal"
+
+ --#TYPE "Memory UECC Event"
+ --#SUMMARY "Memory UECC has returned to Normal"
+ --#ARGUMENTS {}
+ --#SEVERITY INFORMATIONAL
+
+ ::= 901
+
+trapMemoryUeccWarning TRAP-TYPE
+ ENTERPRISE smSD5TrapMIB
+ DESCRIPTION "Memory UECC is Warning"
+
+ --#TYPE "Memory UECC Event"
+ --#SUMMARY "Memory UECC is Warning"
+ --#ARGUMENTS {}
+ --#SEVERITY WARNING
+
+ ::= 902
+
+trapMemoryUeccCritical TRAP-TYPE
+ ENTERPRISE smSD5TrapMIB
+ DESCRIPTION "Memory UECC Critical"
+
+ --#TYPE "Memory UECC Event"
+ --#SUMMARY "Memory UECC is Critical"
+ --#ARGUMENTS {}
+ --#SEVERITY CRITICAL
+
+ ::= 903
+
+
+trapGenericNormal TRAP-TYPE
+ ENTERPRISE smSD5TrapMIB
+ DESCRIPTION "Monitored item has returned to Normal"
+
+ --#TYPE "Generic Event"
+ --#SUMMARY "Monitored item has returned to Normal"
+ --#ARGUMENTS {}
+ --#SEVERITY INFORMATIONAL
+
+ ::= 1001
+
+trapGenericWarning TRAP-TYPE
+ ENTERPRISE smSD5TrapMIB
+ DESCRIPTION "Monitored item is Warning"
+
+ --#TYPE "Generic Event"
+ --#SUMMARY "Monitored item is Warning"
+ --#ARGUMENTS {}
+ --#SEVERITY WARNING
+
+ ::= 1002
+
+trapGenericCritical TRAP-TYPE
+ ENTERPRISE smSD5TrapMIB
+ DESCRIPTION "Monitored item Critical"
+
+ --#TYPE "Generic Event"
+ --#SUMMARY "Monitored item is Critical"
+ --#ARGUMENTS {}
+ --#SEVERITY CRITICAL
+
+ ::= 1003
+
+
+trapBbpStatusNormal TRAP-TYPE
+ ENTERPRISE smSD5TrapMIB
+ DESCRIPTION "BBP has returned to Normal"
+
+ --#TYPE "BBP Event"
+ --#SUMMARY "BBP has returned to Normal"
+ --#ARGUMENTS {}
+ --#SEVERITY INFORMATIONAL
+
+ ::= 1101
+
+trapBbpStatusWarning TRAP-TYPE
+ ENTERPRISE smSD5TrapMIB
+ DESCRIPTION "BBP is Warning"
+
+ --#TYPE "BBP Event"
+ --#SUMMARY "BBP is Warning"
+ --#ARGUMENTS {}
+ --#SEVERITY WARNING
+
+ ::= 1102
+
+trapBbpStatusCritical TRAP-TYPE
+ ENTERPRISE smSD5TrapMIB
+ DESCRIPTION "BBP is Critical"
+
+ --#TYPE "BBP Event"
+ --#SUMMARY "BBP is Critical"
+ --#ARGUMENTS {}
+ --#SEVERITY CRITICAL
+
+ ::= 1103
+
+trapCpuFaultNormal TRAP-TYPE
+ ENTERPRISE smSD5TrapMIB
+ DESCRIPTION "Processor Fault has returned to Normal"
+
+ --#TYPE "Processor Fault Event"
+ --#SUMMARY "Processor Fault has returned to Normal"
+ --#ARGUMENTS {}
+ --#SEVERITY INFORMATIONAL
+
+ ::= 1201
+
+trapCpuFaultWarning TRAP-TYPE
+ ENTERPRISE smSD5TrapMIB
+ DESCRIPTION "Processor Fault is Warning"
+
+ --#TYPE "Processor Fault Event"
+ --#SUMMARY "Processor Fault is Warning"
+ --#ARGUMENTS {}
+ --#SEVERITY WARNING
+
+ ::= 1202
+
+trapCpuFaultCritical TRAP-TYPE
+ ENTERPRISE smSD5TrapMIB
+ DESCRIPTION "Processor Fault is Critical"
+
+ --#TYPE "Processor Fault Event"
+ --#SUMMARY "Processor Fault is Critical"
+ --#ARGUMENTS {}
+ --#SEVERITY CRITICAL
+
+ ::= 1203
+
+trapStorageAdapterStatusNormal TRAP-TYPE
+ ENTERPRISE smSD5TrapMIB
+ DESCRIPTION "Storage Adapter has returned to Normal"
+
+ --#TYPE "Storage Adapter Event"
+ --#SUMMARY "Storage Adapter has returned to Normal"
+ --#ARGUMENTS {}
+ --#SEVERITY INFORMATIONAL
+
+ ::= 1301
+
+trapStorageAdapterStatusWarning TRAP-TYPE
+ ENTERPRISE smSD5TrapMIB
+ DESCRIPTION "Storage Adapter is Warning"
+
+ --#TYPE "Storage Adapter Event"
+ --#SUMMARY "Storage Adapter is Warning"
+ --#ARGUMENTS {}
+ --#SEVERITY WARNING
+
+ ::= 1302
+
+trapStorageAdapterStatusCritical TRAP-TYPE
+ ENTERPRISE smSD5TrapMIB
+ DESCRIPTION "Storage Adapter is Critical"
+
+ --#TYPE "Storage Adapter Event"
+ --#SUMMARY "Storage Adapter is Critical"
+ --#ARGUMENTS {}
+ --#SEVERITY CRITICAL
+
+ ::= 1303
+
+trapBatteryStatusNormal TRAP-TYPE
+ ENTERPRISE smSD5TrapMIB
+ DESCRIPTION "Battery has returned to Normal"
+
+ --#TYPE "Battery Event"
+ --#SUMMARY "Battery has returned to Normal"
+ --#ARGUMENTS {}
+ --#SEVERITY INFORMATIONAL
+
+ ::= 1401
+
+trapBatteryStatusWarning TRAP-TYPE
+ ENTERPRISE smSD5TrapMIB
+ DESCRIPTION "Battery is Warning"
+
+ --#TYPE "Battery Event"
+ --#SUMMARY "Battery is Warning"
+ --#ARGUMENTS {}
+ --#SEVERITY WARNING
+
+ ::= 1402
+
+trapBatteryStatusCritical TRAP-TYPE
+ ENTERPRISE smSD5TrapMIB
+ DESCRIPTION "Battery is Critical"
+
+ --#TYPE "Battery Event"
+ --#SUMMARY "Battery is Critical"
+ --#ARGUMENTS {}
+ --#SEVERITY CRITICAL
+
+ ::= 1403
+
+
+END \ No newline at end of file