diff options
| author | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
|---|---|---|
| committer | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
| commit | 98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch) | |
| tree | 9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/schleifenbauer | |
| download | mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.tar.gz mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.zip | |
Diffstat (limited to 'MIBS/schleifenbauer')
| -rw-r--r-- | MIBS/schleifenbauer/SCHLEIFENBAUER-DATABUS-MIB | 2151 | ||||
| -rw-r--r-- | MIBS/schleifenbauer/SCHLEIFENBAUER-PRODUCTS-MIB | 51 | ||||
| -rw-r--r-- | MIBS/schleifenbauer/SCHLEIFENBAUER-SMI | 68 |
3 files changed, 2270 insertions, 0 deletions
diff --git a/MIBS/schleifenbauer/SCHLEIFENBAUER-DATABUS-MIB b/MIBS/schleifenbauer/SCHLEIFENBAUER-DATABUS-MIB new file mode 100644 index 0000000..823a560 --- /dev/null +++ b/MIBS/schleifenbauer/SCHLEIFENBAUER-DATABUS-MIB @@ -0,0 +1,2151 @@ +------------------------------------------------------------------------------- +-- +-- SCHLEIFENBAUER-DATABUS-MIB.txt: Schleifenbauer MIB for databus devices +-- +-- Copyright (c) 2016, 2020 by Schleifenbauer Holding BV +-- All rights reserved. +-- +------------------------------------------------------------------------------- + +SCHLEIFENBAUER-DATABUS-MIB DEFINITIONS ::= BEGIN + +IMPORTS + MODULE-IDENTITY, + OBJECT-TYPE, + Integer32, + Unsigned32, + NOTIFICATION-TYPE + FROM SNMPv2-SMI + OBJECT-GROUP, + NOTIFICATION-GROUP, + MODULE-COMPLIANCE + FROM SNMPv2-CONF + TEXTUAL-CONVENTION, + DisplayString + FROM SNMPv2-TC + schleifenbauerMgmt + FROM SCHLEIFENBAUER-SMI; + +schleifenbauerDatabusMIB MODULE-IDENTITY + LAST-UPDATED + "202004280000Z" -- April 28th, 2020 + ORGANIZATION + "Schleifenbauer Engineering" + CONTACT-INFO + "Schleifenbauer Engineering + Alain Schuermans + Chief Technology Officer + Rietwaard 15 + 5236 WC 's-Hertogenbosch + The Netherlands + t +31 (0)73 52 30256 + f +31 (0)73 521 23 83 + alain@schleifenbauer.eu + www.schleifenbauer.eu" + DESCRIPTION + "This MIB describes the SNMP functions of network enabled databus + devices. + + Copyright (c) 2016, 2020 by Schleifenbauer Holding BV + " + REVISION + "202004280000Z" -- April 28th, 2020 + DESCRIPTION + "1. Added performance monitoring registers + 2. Added sdbDevStUsbMode register + 3. Added sdbDevIdDeviceType register + 4. Added sdbDevIdLocateUnit" + REVISION + "201703060000Z" -- March 3rd, 2017 + DESCRIPTION + "Renamed Deci prefix of custom TEXTUAL-CONVENTIONs to Centi" + REVISION + "201610210000Z" -- October 21th, 2016 + DESCRIPTION + "1. Added sdbDevSsOutletVoltageDropAlert object. + 2. Added sdbDevStAutoResetAlerts object. + 3. Added sdbDevStExtendedNames object. + 4. Added sdbDevSsOutletVoltageDropAlertDetected object." + REVISION + "201606160000Z" -- June 16th, 2016 + DESCRIPTION + "1. Fixed incorrect range of sdbDevIdIndex." + REVISION + "201605100000Z" -- May 10th, 2016 + DESCRIPTION + "1. Added sdbDevOutMtPowerVoltAmpere object. + 2. Added sdbDevOutMtPowerWatt object." + REVISION + "201603240000Z" -- March 24th, 2016 + DESCRIPTION + "1. Added sdbMgmtStsRingState object. + 2. Added sdbMgmtStsBreachIndex object. + 3. Added sdbMgmtStsRingStateChanged notification." + REVISION + "201602190000Z" -- February 19th, 2016 + DESCRIPTION + "1. Fixed incorrect description of sdbDevIdIndex. + 2. Fixed description of sdbDevSsSensorChangeAlertDetected. Removed + sdbDevSnsType from description." + REVISION + "201510230000Z" -- October 23th, 2015 + DESCRIPTION + "The initial revision of this MIB module" + ::= { schleifenbauerMgmt 1 } + +CentiValue ::= TEXTUAL-CONVENTION + DISPLAY-HINT "d-2" + STATUS current + DESCRIPTION + "Data type for reporting generic measurements associated with + environmental sensors. If the underlying hardware sensor indicates + 21.1 degrees Celsius, then the SNMP agent will report a value of 2110 + CentiValue." + SYNTAX Integer32 (0..327680) + +KiloWattHour ::= TEXTUAL-CONVENTION + DISPLAY-HINT "d" + STATUS current + DESCRIPTION + "Data type for reporting measurements associated with energy + accumulation sensors. If the underlying hardware sensor indicates 1 + kWh, then the SNMP agent will report a value of 1 kWh." + SYNTAX Integer32 (0..16777215) + +-- START MIB -- + +CentiAmpere ::= TEXTUAL-CONVENTION + DISPLAY-HINT "d-2" + STATUS current + DESCRIPTION + "Data type for reporting measurements and thresholds associated with + current sensors. If the underlying hardware sensor indicates 1.1 A, + then the SNMP agent will report a value of 110 CentiAmpere." + SYNTAX Integer32 (0..327680) + +CentiCelsius ::= TEXTUAL-CONVENTION + DISPLAY-HINT "d-2" + STATUS current + DESCRIPTION + "Data type for reporting sensor readings associated with temperature + sensors. If the underlying hardware sensor indicates 20.1 degrees + Celsius, then the SNMP agent will report a value of 2010 CentiCelsius." + SYNTAX Integer32 (0..9900) + +CentiPercent ::= TEXTUAL-CONVENTION + DISPLAY-HINT "d-2" + STATUS current + DESCRIPTION + "Data type for reporting calculated percentages. If the calculated + percentage is 98.3%, then the SNMP agent will report a value of 9830 + CentiPercent." + SYNTAX Integer32 (0..10000) + +CentiVolt ::= TEXTUAL-CONVENTION + DISPLAY-HINT "d-2" + STATUS current + DESCRIPTION + "Data type for reporting measurements and thresholds associated with + voltage sensors. If the underlying hardware sensor indicates 231.1 V, + then the SNMP agent will report a value of 23110 CentiVolt." + SYNTAX Integer32 (0..327680) + +MilliSecond ::= TEXTUAL-CONVENTION + DISPLAY-HINT "d" + STATUS current + DESCRIPTION + "Duration in milliseconds" + SYNTAX Integer32 + +Second ::= TEXTUAL-CONVENTION + DISPLAY-HINT "d" + STATUS current + DESCRIPTION + "Duration in seconds." + SYNTAX Integer32 + +sdbMIBNotifications OBJECT IDENTIFIER ::= { schleifenbauerDatabusMIB 0 } +sdbMIBObjects OBJECT IDENTIFIER ::= { schleifenbauerDatabusMIB 1 } +sdbMIBConformance OBJECT IDENTIFIER ::= { schleifenbauerDatabusMIB 2 } + +sdbMgmt OBJECT IDENTIFIER ::= { sdbMIBObjects 1} +sdbDevice OBJECT IDENTIFIER ::= { sdbMIBObjects 2 } + +sdbMgmtStatus OBJECT IDENTIFIER ::= { sdbMgmt 1 } +sdbMgmtControl OBJECT IDENTIFIER ::= { sdbMgmt 2 } + +sdbDevIdentification OBJECT IDENTIFIER ::= { sdbDevice 1 } +sdbDevConfiguration OBJECT IDENTIFIER ::= { sdbDevice 2 } +sdbDevSystemStatus OBJECT IDENTIFIER ::= { sdbDevice 3 } +sdbDevReset OBJECT IDENTIFIER ::= { sdbDevice 4 } +sdbDevSettings OBJECT IDENTIFIER ::= { sdbDevice 5 } +sdbDevInput OBJECT IDENTIFIER ::= { sdbDevice 6 } +sdbDevOutlet OBJECT IDENTIFIER ::= { sdbDevice 7 } +sdbDevSensor OBJECT IDENTIFIER ::= { sdbDevice 8 } +sdbDevPerformance OBJECT IDENTIFIER ::= { sdbDevice 9 } + +sdbMIBCompliances OBJECT IDENTIFIER ::= { sdbMIBConformance 1 } +sdbMIBGroups OBJECT IDENTIFIER ::= { sdbMIBConformance 2 } + +sdbMgmtStsDevices OBJECT-TYPE + SYNTAX Integer32 (1..512) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of devices on the databus." + ::= { sdbMgmtStatus 1} + +sdbMgmtStsAddressableDevices OBJECT-TYPE + SYNTAX Integer32 (1..255) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of devices on the databus addressable by snmp." + ::= { sdbMgmtStatus 2 } + +sdbMgmtStsNewDevices OBJECT-TYPE + SYNTAX Integer32 (1..255) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of new devices on the databus." + ::= { sdbMgmtStatus 3 } + +sdbMgmtStsDuplicateDevices OBJECT-TYPE + SYNTAX Integer32 (1..255) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of duplicate devices on the databus." + ::= { sdbMgmtStatus 4 } + +sdbMgmtStsRingState OBJECT-TYPE + SYNTAX INTEGER { + open(0), + closed(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "If the device is in a bridge-like mode, this will indicate the actual + state of the databus." + ::= { sdbMgmtStatus 5 } + +sdbMgmtStsRingBreachIndex OBJECT-TYPE + SYNTAX Integer32 (0..65535) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicates the breach index if the current state of the data bus is + open. If the data bus is closed this has no meaning." + ::= { sdbMgmtStatus 6 } + +sdbMgmtCtrlScan OBJECT-TYPE + SYNTAX INTEGER { + idle(0), + scan(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Perform a bus scan. + To verify if scanning is completed the value of this object can be + read. During the bus scan the value remains 1. When the bus scan + completed the value will be 0." + ::= { sdbMgmtControl 1 } + +sdbMgmtCtrlRenumberAllFromN OBJECT-TYPE + SYNTAX Integer32 (0..65535) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Renumber all devices on the databus. + If set to 0 all units will be set to 0. If set to another value, all + units will be numbered in sequence starting from the value set." + ::= { sdbMgmtControl 2 } + +sdbMgmtCtrlRenumberZeros OBJECT-TYPE + SYNTAX INTEGER { + idle(0), + renumber(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Renumber all devices on the databus having address 0. + Renumbering will be done in sequence. The sequence starts with the + highest address found on the databus." + ::= { sdbMgmtControl 3 } + +sdbMgmtCtrlDevicesTable OBJECT-TYPE + SYNTAX SEQUENCE OF SdbMgmtCtrlDevicesEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table containing information of devices connected to the databus. + The number of entries is given by the value of sdbMgmtStsDevices." + ::= { sdbMgmtControl 4 } + +sdbMgmtCtrlDevicesEntry OBJECT-TYPE + SYNTAX SdbMgmtCtrlDevicesEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Information entry containing objects of a particular databus device." + INDEX { sdbMgmtCtrlDevIndex } + ::= { sdbMgmtCtrlDevicesTable 1 } + +SdbMgmtCtrlDevicesEntry ::= + SEQUENCE { + sdbMgmtCtrlDevIndex Integer32, + sdbMgmtCtrlDevUnitAddress Integer32, + sdbMgmtCtrlDevHardwareAddress DisplayString, + sdbMgmtCtrlDevIsNew Integer32, + sdbMgmtCtrlDevIsDuplicate Integer32 + } + +sdbMgmtCtrlDevIndex OBJECT-TYPE + SYNTAX Integer32 (1..255) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A unique value for each device. Its value ranges between 1 and the + value of sdbMgmtStsDevices with a maximum of 255. The value for each + device will remain constant until the next scan is performed." + ::= { sdbMgmtCtrlDevicesEntry 1 } + +sdbMgmtCtrlDevUnitAddress OBJECT-TYPE + SYNTAX Integer32 (0..65535) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "User defined address. + This will be used for addressing the device on the databus." + ::= { sdbMgmtCtrlDevicesEntry 2 } + +sdbMgmtCtrlDevHardwareAddress OBJECT-TYPE + SYNTAX DisplayString (SIZE(17)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Hardware serial number. + This cannot be changed. It can be used as backup unit address. + format as 3 unsigned ints separated by dashes: int - int - int" + ::= { sdbMgmtCtrlDevicesEntry 3 } + +sdbMgmtCtrlDevIsNew OBJECT-TYPE + SYNTAX INTEGER { + no(0), + yes(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indication if the device is new on the databus." + ::= { sdbMgmtCtrlDevicesEntry 4 } + +sdbMgmtCtrlDevIsDuplicate OBJECT-TYPE + SYNTAX + INTEGER { + no(0), + yes(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indication if the device is conflicting with another device on the + databus." + ::= { sdbMgmtCtrlDevicesEntry 5 } + +sdbDevIdTable OBJECT-TYPE + SYNTAX SEQUENCE OF SdbDevIdEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table containing identification information of devices connected to + the databus. + The number of entries is given by the value of + sdbMgmtStsAddressableDevices." + ::= { sdbDevIdentification 1 } + +sdbDevIdEntry OBJECT-TYPE + SYNTAX SdbDevIdEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Information entry containing information objects of a particular + databus device." + INDEX { sdbDevIdIndex } + ::= { sdbDevIdTable 1 } + +SdbDevIdEntry ::= + SEQUENCE { + sdbDevIdSPDMVersion Integer32, + sdbDevIdFirmwareVersion Integer32, + sdbDevIdBuildNumber DisplayString, + sdbDevIdSalesOrderNumber DisplayString, + sdbDevIdProductId DisplayString, + sdbDevIdSerialNumber DisplayString, + sdbDevIdHardwareAddress DisplayString, + sdbDevIdMacAddress DisplayString, + sdbDevIdUnitAddress Integer32, + sdbDevIdName DisplayString, + sdbDevIdLocation DisplayString, + sdbDevIdVanityTag DisplayString, + sdbDevIdIndex Integer32, + sdbDevIdDeviceType Integer32, + sdbDevIdLocateUnit Integer32 + } + +sdbDevIdSPDMVersion OBJECT-TYPE + SYNTAX Integer32 (0..9999) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Data model version." + ::= { sdbDevIdEntry 1 } + +sdbDevIdFirmwareVersion OBJECT-TYPE + SYNTAX Integer32 (0..9999) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The firmware revision number." + ::= { sdbDevIdEntry 2 } + +sdbDevIdBuildNumber OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..12)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Date and time the firmware was built." + ::= { sdbDevIdEntry 3 } + +sdbDevIdSalesOrderNumber OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..16)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "SP sales order number." + ::= { sdbDevIdEntry 4 } + +sdbDevIdProductId OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..16)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "SP product id." + ::= { sdbDevIdEntry 5 } + +sdbDevIdSerialNumber OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..16)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "SP serial number." + ::= { sdbDevIdEntry 6 } + +sdbDevIdHardwareAddress OBJECT-TYPE + SYNTAX DisplayString (SIZE(17)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Hardware serial number. + This can not be changed. It can be used as backup unit address. + Format as 3 unsigned ints separated by dashes (-) + e.g. 12345-54321-00000" + ::= { sdbDevIdEntry 7 } + +sdbDevIdMacAddress OBJECT-TYPE + SYNTAX DisplayString (SIZE(17)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The MAC address. + This can not be changed. It represents an 802 MAC address as if it + were transmitted least significant bit first. + Format as six groups of 2 hexadecimal digits separated by colons (:) + e.g. D0:22:12:B0:00:00" + ::= { sdbDevIdEntry 8 } + +sdbDevIdUnitAddress OBJECT-TYPE + SYNTAX Integer32 (0..65535) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "User defined address. + This will be used for addressing the device on the databus." + ::= { sdbDevIdEntry 9 } + +sdbDevIdName OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..16)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "User configurable device name or identifier." + ::= { sdbDevIdEntry 10 } + +sdbDevIdLocation OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..16)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "User configurable device location identifier." + ::= { sdbDevIdEntry 11 } + +sdbDevIdVanityTag OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..20)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Characters to be displayed as vanity text in display." + ::= { sdbDevIdEntry 12 } + +sdbDevIdIndex OBJECT-TYPE + SYNTAX Integer32 (1..65535) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A unique value for each device. Its value represents the unit address + of the device and is used to address individual devices in the tree. + The value for each device will remain constant until the next scan is + performed." + ::= { sdbDevIdEntry 13 } + +sdbDevIdDeviceType OBJECT-TYPE + SYNTAX INTEGER { + pdu(0), + dpm(1), + hpdu-G3(2), + dpm27e(3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A unique value for each device group. + Its value represents the device type of the device. + Refer to manual for more information." + ::= { sdbDevIdEntry 14 } + +sdbDevIdLocateUnit OBJECT-TYPE + SYNTAX INTEGER { + off(0), + on(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The LCD-backlight flashes in a heartbeat rhythm to locate the unit." + ::= { sdbDevIdEntry 15 } + +sdbDevCfTable OBJECT-TYPE + SYNTAX SEQUENCE OF SdbDevCfEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table containing configuration information of devices connected to + the databus. + The number of entries is given by the value of + sdbMgmtStsAddressableDevices." + ::= { sdbDevConfiguration 1 } + +sdbDevCfEntry OBJECT-TYPE + SYNTAX SdbDevCfEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Configuration entry containing configuration objects of a particular + databus device." + INDEX { sdbDevIdIndex } + ::= { sdbDevCfTable 1 } + +SdbDevCfEntry ::= + SEQUENCE { + sdbDevCfPhases Integer32, + sdbDevCfOutletsTotal Integer32, + sdbDevCfOutletsSwitched Integer32, + sdbDevCfOutletsMetered Integer32, + sdbDevCfSensors Integer32, + sdbDevCfMaximumLoad Integer32 + } + +sdbDevCfPhases OBJECT-TYPE + SYNTAX Integer32 (0 | 1 | 3) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of phases for input metering." + ::= { sdbDevCfEntry 1 } + +sdbDevCfOutletsTotal OBJECT-TYPE + SYNTAX Integer32 (0..48) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total number of outlets including hardwired without switch/metered + modules." + ::= { sdbDevCfEntry 2 } + +sdbDevCfOutletsSwitched OBJECT-TYPE + SYNTAX Integer32 (0..48) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of switched outlets. + If outlet numbering is non-contiguous its the highest outlet number." + ::= { sdbDevCfEntry 3 } + +sdbDevCfOutletsMetered OBJECT-TYPE + SYNTAX Integer32 (0..48) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of metered outlets. + If outlet numbering is non-contiguous its the highest outlet number." + ::= { sdbDevCfEntry 4 } + +sdbDevCfSensors OBJECT-TYPE + SYNTAX Integer32 (0..16) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number sensors." + ::= { sdbDevCfEntry 5 } + +sdbDevCfMaximumLoad OBJECT-TYPE + SYNTAX Integer32 (16 | 32) + UNITS "A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Maximum rated load of device per phase" + ::= { sdbDevCfEntry 6 } + +sdbDevSsTable OBJECT-TYPE + SYNTAX SEQUENCE OF SdbDevSsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table containing system status information of devices connected to + the databus. + The number of entries is given by the value of + sdbMgmtStsAddressableDevices." + ::= { sdbDevSystemStatus 1 } + +sdbDevSsEntry OBJECT-TYPE + SYNTAX SdbDevSsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "System status entry containing system status objects of a particular + databus device." + INDEX { sdbDevIdIndex } + ::= { sdbDevSsTable 1 } + +SdbDevSsEntry ::= + SEQUENCE { + sdbDevSsDeviceStatusCode Integer32, + sdbDevSsTemperatureAlert Integer32, + sdbDevSsInputCurrentAlert Integer32, + sdbDevSsOutletCurrentAlert Integer32, + sdbDevSsInputVoltageAlert Integer32, + sdbDevSsOutletCurrentDropAlert Integer32, + sdbDevSsInputCurrentDropAlert Integer32, + sdbDevSsSensorChangeAlert Integer32, + sdbDevSsOutletVoltageDropAlert Integer32 + } + +sdbDevSsDeviceStatusCode OBJECT-TYPE + SYNTAX Integer32 (0..255) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Returns an internal status or error code. + A value of 0 means OK. + If not 0 it can be any of the following codes. Multiple status codes + can be active at the same time. The value will be the sum of the + active status codes. + + 1 = alert flagged + 2 = settings(s) initialized + 4 = power-on reset + 8 = external reset + 16 = watchdog timer caused reset + 32 = brownout detected + 64 = controller error + 128 = slave module was reset" + ::= { sdbDevSsEntry 1 } + +sdbDevSsTemperatureAlert OBJECT-TYPE + SYNTAX Integer32 (0..2) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "An alert has been raised due to temperature exceeding treshhold. + 0 = no alert + 1 = internal temperature sensor + 2 = external temperature sensor" + ::= { sdbDevSsEntry 2 } + +sdbDevSsInputCurrentAlert OBJECT-TYPE + SYNTAX Integer32 (0..3) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "An alert has been raised due to current exceeding treshhold. + The value indicates the exceeding phase. 0 = no alert." + ::= { sdbDevSsEntry 3 } + +sdbDevSsOutletCurrentAlert OBJECT-TYPE + SYNTAX Integer32 (0..48) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "An alert has been raised due to current exceeding treshhold. + The value indicates the exceeding outlet. 0 = no alert." + ::= { sdbDevSsEntry 4 } + +sdbDevSsInputVoltageAlert OBJECT-TYPE + SYNTAX Integer32 (0..3) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "An alert has been raised due to a voltage dip. + The value indicates the dipped phase. 0 = no alert." + ::= { sdbDevSsEntry 5 } + +sdbDevSsOutletCurrentDropAlert OBJECT-TYPE + SYNTAX Integer32 (0..48) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "An alert has been raised due to the current of a metered outlet + suddenly dropping to near zero, possibly indicating a blown fuse. + The value indicates the dropped outlet. 0 = no alert." + ::= { sdbDevSsEntry 6 } + +sdbDevSsInputCurrentDropAlert OBJECT-TYPE + SYNTAX Integer32 (0..3) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "An alert has been raised due to the current of a metered input + suddenly dropping to near zero, possibly indicating a blown fuse. + The value indicates the dropped phase. 0 = no alert." + ::= { sdbDevSsEntry 7 } + +sdbDevSsSensorChangeAlert OBJECT-TYPE + SYNTAX Integer32 (0..16) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "An alert has been raised due to a change in the number of sensors. + The value indicates the previous amount of sensors." + ::= { sdbDevSsEntry 8 } + +sdbDevSsOutletVoltageDropAlert OBJECT-TYPE + SYNTAX Integer32 (0..48) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "An alert has been raised due to voltage drop on this outlet. + The value indicates the first failed outlet." + ::= { sdbDevSsEntry 9 } + + +sdbDevRsTable OBJECT-TYPE + SYNTAX SEQUENCE OF SdbDevRsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table providing reset capabilities to devices connected to the + databus. + The number of entries is given by the value of + sdbMgmtStsAddressableDevices." + ::= { sdbDevReset 1 } + +sdbDevRsEntry OBJECT-TYPE + SYNTAX SdbDevRsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Reset entry providing reset objects of a particular databus device." + INDEX { sdbDevIdIndex } + ::= { sdbDevRsTable 1 } + +SdbDevRsEntry ::= + SEQUENCE { + sdbDevRsReboot Integer32, + sdbDevRsResetAlerts Integer32, + sdbDevRsZeroInputKWhSubtotal Integer32, + sdbDevRsZeroOutletKWhSubtotal Integer32, + sdbDevRsResetPeaksAndDips Integer32 + } + +sdbDevRsReboot OBJECT-TYPE + SYNTAX + INTEGER { + idle(0), + reboot(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Warm reboot/reset of device controller. + NOTE: this will have NO effect on outlet status!" + ::= { sdbDevRsEntry 1 } + +sdbDevRsResetAlerts OBJECT-TYPE + SYNTAX + INTEGER { + idle(0), + reset(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Reset all alert signals and device status code." + ::= { sdbDevRsEntry 2 } + +sdbDevRsZeroInputKWhSubtotal OBJECT-TYPE + SYNTAX + INTEGER { + idle(0), + zero(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Reset of all input kWh subtotal counters to zero." + ::= { sdbDevRsEntry 3 } + +sdbDevRsZeroOutletKWhSubtotal OBJECT-TYPE + SYNTAX + INTEGER { + idle(0), + zero(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Reset of all outlet kWh subtotal counter to zero." + ::= { sdbDevRsEntry 4 } + +sdbDevRsResetPeaksAndDips OBJECT-TYPE + SYNTAX + INTEGER { + idle(0), + reset(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Reset all peak and dip values to zero." + ::= { sdbDevRsEntry 5 } + +sdbDevStTable OBJECT-TYPE + SYNTAX SEQUENCE OF SdbDevStEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table containing setting information of devices connected to the + databus. + The number of entries is given by the value of + sdbMgmtStsAddressableDevices." + ::= { sdbDevSettings 1 } + +sdbDevStEntry OBJECT-TYPE + SYNTAX SdbDevStEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Setting entry containing settings objects of a particular databus + device." + INDEX { sdbDevIdIndex } + ::= { sdbDevStTable 1 } + +SdbDevStEntry ::= + SEQUENCE { + sdbDevStAutoResetAlerts Integer32, + sdbDevStExtendedNames Integer32, + sdbDevStPeakDuration MilliSecond, + sdbDevStFixedOutletDelay MilliSecond, + sdbDevStPowerSaverMode Second, + sdbDevStOutletPowerUpMode Integer32, + sdbDevStMaximumTemperature Integer32, + sdbDevStDisplayOrientation Integer32, + sdbDevStLocalAlertReset Integer32, + sdbDevStCurrentDropDetection Integer32, + sdbDevStUsbMode Integer32 + } + +sdbDevStAutoResetAlerts OBJECT-TYPE + SYNTAX Integer32 (0..65535) + UNITS "seconds" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Auto reset alerts configuration. + If set to 0 the auto reset alerts feature is disabled. If set to a + value greater then 0, the auto reset alerts feature is enabled and + alerts will get cleared after the configured amount of seconds since + the last alert condition have passed." + ::= { sdbDevStEntry 2 } + +sdbDevStExtendedNames OBJECT-TYPE + SYNTAX + INTEGER { + disabled(0), + enabled(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Use original or longer names for inputs, outlets and sensors." + ::= { sdbDevStEntry 3 } + +sdbDevStPeakDuration OBJECT-TYPE + SYNTAX MilliSecond (0..65535) + UNITS "ms" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Amount of ms a current peak should last before an alert is raised." + ::= { sdbDevStEntry 4 } + +sdbDevStFixedOutletDelay OBJECT-TYPE + SYNTAX MilliSecond (100..65535) + UNITS "ms" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Minimal delay between two successive relay switches in milliseconds. + Minimal delay is 100 ms. Will always be respected!" + ::= { sdbDevStEntry 5 } + +sdbDevStPowerSaverMode OBJECT-TYPE + SYNTAX Second (0 | 10 | 60 | 120 | 240) + UNITS "s" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Set backlight on time in seconds. + 0 keeps display always on. + Note that keeping the backlight on may decrease luminosity over time." + ::= { sdbDevStEntry 6 } + +sdbDevStOutletPowerUpMode OBJECT-TYPE + SYNTAX + INTEGER { + off(0), -- off + sameState(1), -- same state as at power down + sameStateDelayed(2) -- same state as at power down but delayed by + -- individual delay timer. + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Behaviour of outlets on power-up." + ::= { sdbDevStEntry 7 } + +sdbDevStMaximumTemperature OBJECT-TYPE + SYNTAX Integer32 (0..99) + UNITS "degrees Celsius" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Maximum temperature threshold + An alert will be generated whenever the temperature is above this + value. Zero means disabled." + ::= { sdbDevStEntry 8 } + +sdbDevStDisplayOrientation OBJECT-TYPE + SYNTAX + INTEGER { + noDisplay(0), + verticalDisplayOnTop(1), + verticalDisplayUpsideDown(2), + horizontalDisplayAtLeft(3), + horizontalDisplayAtRight(4) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Display orientation." + ::= { sdbDevStEntry 9 } + +sdbDevStLocalAlertReset OBJECT-TYPE + SYNTAX + INTEGER { + notAllowed(0), + allowed(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Allow alerts to be reset locally on device by pushing one of the + buttons." + ::= { sdbDevStEntry 10 } + +sdbDevStCurrentDropDetection OBJECT-TYPE + SYNTAX + INTEGER { + off(0), + inputsOnly(1), + outletsOnly(2), + inputsAndOutlets(3) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enables the current drop detection function." + ::= { sdbDevStEntry 11 } + +sdbDevStUsbMode OBJECT-TYPE + SYNTAX + INTEGER { + usbDisabled(0), + onlyFirmwareUpdates(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Allow the USB port to be used for specific tasks" + ::= { sdbDevStEntry 13 } + +sdbDevInTable OBJECT-TYPE + SYNTAX SEQUENCE OF SdbDevInEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table containing information of inputs of devices connected to the + databus." + ::= { sdbDevInput 1 } + +sdbDevInEntry OBJECT-TYPE + SYNTAX SdbDevInEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Inputs entry containing objects of an input of a particular databus + device. + Note that this table has two indexes. sdbDevIdIndex to identify a + particular device and sdbDevInIndex to identify a particular input + of the device identified by sdbDevIdIndex." + INDEX { + sdbDevIdIndex, + sdbDevInIndex + } + ::= { sdbDevInTable 1 } + +SdbDevInEntry ::= + SEQUENCE { + sdbDevInIndex Integer32, + sdbDevInKWhTotal KiloWattHour, + sdbDevInKWhSubtotal KiloWattHour, + sdbDevInPowerFactor CentiPercent, + sdbDevInActualCurrent CentiAmpere, + sdbDevInPeakCurrent CentiAmpere, + sdbDevInActualVoltage CentiVolt, + sdbDevInMinVoltage CentiVolt, + sdbDevInPowerVoltAmpere Integer32, + sdbDevInPowerWatt Integer32, + sdbDevInMaxAmps CentiAmpere, + sdbDevInCTRatio Integer32, + sdbDevInName DisplayString, + sdbDevInZeroKWhSubtotal Integer32 + } + +sdbDevInIndex OBJECT-TYPE + SYNTAX Integer32 (1..48) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A unique value for each input. Its value ranges between 1 and the + value of sdbDevCfPhases." + ::= { sdbDevInEntry 1 } + +sdbDevInKWhTotal OBJECT-TYPE + SYNTAX KiloWattHour + UNITS "kWh" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total kWh value of an input. This value can not be reset." + ::= { sdbDevInEntry 2 } + +sdbDevInKWhSubtotal OBJECT-TYPE + SYNTAX KiloWattHour + UNITS "kWh" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Subtotal kWh value of an input. This value can be reset." + ::= { sdbDevInEntry 3 } + +sdbDevInPowerFactor OBJECT-TYPE + SYNTAX CentiPercent + UNITS "%" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Power factor of input. + The power factor of an AC power system is defined as the ratio of the + real or active power to the apparent power and is a number between 0 + and 1. This value is expressed as a percentage between 0% and 100%." + ::= { sdbDevInEntry 4 } + +sdbDevInActualCurrent OBJECT-TYPE + SYNTAX CentiAmpere + UNITS "A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Actual apparent, RMS current." + ::= { sdbDevInEntry 5 } + +sdbDevInPeakCurrent OBJECT-TYPE + SYNTAX CentiAmpere + UNITS "A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Peak apparent, RMS current. + Highest value since last reset of the alerts." + ::= { sdbDevInEntry 6 } + +sdbDevInActualVoltage OBJECT-TYPE + SYNTAX CentiVolt + UNITS "V" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The actual voltage." + ::= { sdbDevInEntry 7 } + +sdbDevInMinVoltage OBJECT-TYPE + SYNTAX CentiVolt + UNITS "V" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "RMS voltage dip. + Lowest value since reset of alerts." + ::= { sdbDevInEntry 8 } + +sdbDevInPowerVoltAmpere OBJECT-TYPE + SYNTAX Integer32 (0..327680) + UNITS "VA" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Calculated apparent power." + ::= { sdbDevInEntry 9 } + +sdbDevInPowerWatt OBJECT-TYPE + SYNTAX Integer32 (0..327680) + UNITS "W" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Calculated real power." + ::= { sdbDevInEntry 10 } + +sdbDevInMaxAmps OBJECT-TYPE + SYNTAX CentiAmpere + UNITS "A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Maximum current per input phase. + Should last at least sdbDevStPeakDuration ms before triggering an + alert." + ::= { sdbDevInEntry 11 } + +sdbDevInCTRatio OBJECT-TYPE + SYNTAX Integer32 (0..255) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The multiplier to use for the input CTs." + ::= { sdbDevInEntry 12 } + +sdbDevInName OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..8)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "User configurable naming of inputs or phases." + ::= { sdbDevInEntry 13 } + +sdbDevInZeroKWhSubtotal OBJECT-TYPE + SYNTAX + INTEGER { + idle(0), + zero(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Reset input kWh subtotal counter of a single input to zero." + ::= { sdbDevInEntry 14 } + +sdbDevOutTable OBJECT-TYPE + SYNTAX SEQUENCE OF SdbDevOutEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table containing information of outlets of devices connected to the + databus." + ::= { sdbDevOutlet 1 } + +sdbDevOutEntry OBJECT-TYPE + SYNTAX SdbDevOutEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Outlets entry containing objects of an outlet of a particular databus + device. + Note that this table has two indexes. sdbDevIdIndex to identify a + particular device and sdbDevOutIndex to identify a particular outlet + of the device identified by sdbDevIdIndex." + INDEX { + sdbDevIdIndex, + sdbDevOutIndex + } + ::= { sdbDevOutTable 1 } + +SdbDevOutEntry ::= + SEQUENCE { + sdbDevOutIndex Integer32, + sdbDevOutName DisplayString + } + +sdbDevOutIndex OBJECT-TYPE + SYNTAX Integer32 (1..48) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A unique value for each outlet. Its value ranges between 1 and the + value of sdbDevCfOutletsTotal." + ::= { sdbDevOutEntry 1 } + +sdbDevOutName OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..8)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "User configurable naming of individual outlets." + ::= { sdbDevOutEntry 2 } + +sdbDevOutMtTable OBJECT-TYPE + SYNTAX SEQUENCE OF SdbDevOutMtEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table containing information of metered outlets of devices connected + to the databus." + ::= { sdbDevOutlet 2 } + +sdbDevOutMtEntry OBJECT-TYPE + SYNTAX SdbDevOutMtEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Metered outlets entry containing objects of a metered outlet of a + particular databus device. + Note that this table has two indexes. sdbDevIdIndex to identify a + particular device and sdbDevOutMtIndex to identify a particular outlet + of the device identified by sdbDevIdIndex." + INDEX { + sdbDevIdIndex, + sdbDevOutMtIndex + } + ::= { sdbDevOutMtTable 1 } + +SdbDevOutMtEntry ::= + SEQUENCE { + sdbDevOutMtIndex Integer32, + sdbDevOutMtKWhTotal KiloWattHour, + sdbDevOutMtKWhSubtotal KiloWattHour, + sdbDevOutMtPowerFactor CentiPercent, + sdbDevOutMtActualCurrent CentiAmpere, + sdbDevOutMtPeakCurrent CentiAmpere, + sdbDevOutMtActualVoltage CentiVolt, + sdbDevOutMtMaxAmps CentiAmpere, + sdbDevOutMtCTRatio Integer32, + sdbDevOutMtPowerVoltAmpere Integer32, + sdbDevOutMtPowerWatt Integer32 + } + +sdbDevOutMtIndex OBJECT-TYPE + SYNTAX Integer32 (1..48) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A unique value for each outlet. Its value ranges between 1 and the + value of sdbDevCfOutletsMetered." + ::= { sdbDevOutMtEntry 1 } + +sdbDevOutMtKWhTotal OBJECT-TYPE + SYNTAX KiloWattHour + UNITS "kWh" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total kWh value of an outlet. This value can not be reset." + ::= { sdbDevOutMtEntry 2 } + +sdbDevOutMtKWhSubtotal OBJECT-TYPE + SYNTAX KiloWattHour + UNITS "kWh" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Subotal kWh value of an outlet. This value can be reset." + ::= { sdbDevOutMtEntry 3 } + +sdbDevOutMtPowerFactor OBJECT-TYPE + SYNTAX CentiPercent + UNITS "%" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Power factor of outlet. + The power factor of an AC power system is defined as the ratio of the + real or active power to the apparent power and is a number between 0 + and 1. This number is expressed as a percentage between 0% and 100%." + ::= { sdbDevOutMtEntry 4 } + +sdbDevOutMtActualCurrent OBJECT-TYPE + SYNTAX CentiAmpere + UNITS "A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Actual apparent, RMS current." + ::= { sdbDevOutMtEntry 5 } + +sdbDevOutMtPeakCurrent OBJECT-TYPE + SYNTAX CentiAmpere + UNITS "A" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Peak apparent, RMS current. + Highest value since last reset of the alerts." + ::= { sdbDevOutMtEntry 6 } + +sdbDevOutMtActualVoltage OBJECT-TYPE + SYNTAX CentiVolt + UNITS "V" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Actual voltage on outlet." + ::= { sdbDevOutMtEntry 7 } + +sdbDevOutMtMaxAmps OBJECT-TYPE + SYNTAX CentiAmpere + UNITS "A" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Maximum current per outlet. + Should last at least sdbDevStPeakDuration ms before triggering an + alert." + ::= { sdbDevOutMtEntry 8 } + +sdbDevOutMtCTRatio OBJECT-TYPE + SYNTAX Integer32 (0..255) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The multiplier to use for the outlet CTs." + ::= { sdbDevOutMtEntry 9 } + +sdbDevOutMtPowerVoltAmpere OBJECT-TYPE + SYNTAX Integer32 (0..327680) + UNITS "VA" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Calculated apparent power." + ::= { sdbDevOutMtEntry 10 } + +sdbDevOutMtPowerWatt OBJECT-TYPE + SYNTAX Integer32 (0..327680) + UNITS "W" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Calculated real power." + ::= { sdbDevOutMtEntry 11 } + +sdbDevOutSwTable OBJECT-TYPE + SYNTAX SEQUENCE OF SdbDevOutSwEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table containing information of switched outlets of devices + connected to the databus." + ::= { sdbDevOutlet 3 } + +sdbDevOutSwEntry OBJECT-TYPE + SYNTAX SdbDevOutSwEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Switched outlets entry containing objects of a switched outlet of a + particular databus device. + Note that this table has two indexes. sdbDevIdIndex to identify a + particular device and sdbDevOutSwIndex to identify a particular outlet + of the device identified by sdbDevIdIndex." + INDEX { + sdbDevIdIndex, + sdbDevOutSwIndex + } + ::= { sdbDevOutSwTable 1 } + +SdbDevOutSwEntry ::= + SEQUENCE { + sdbDevOutSwIndex Integer32, + sdbDevOutSwCurrentState Integer32, + sdbDevOutSwScheduled Integer32, + sdbDevOutSwUnlock Integer32, + sdbDevOutSwIndividualOutletDelay Second, + sdbDevOutSwReboot Integer32 + } + +sdbDevOutSwIndex OBJECT-TYPE + SYNTAX Integer32 (1..48) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A unique value for each outlet. Its value ranges between 1 and the + value of sdbDevCfOutletsSwitched." + ::= { sdbDevOutSwEntry 1 } + +sdbDevOutSwCurrentState OBJECT-TYPE + SYNTAX + INTEGER { + off(0), + on(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The actual state of the outlet relay. + Note that Writing is only effective after setting sdbDevOutSwUnlock." + ::= { sdbDevOutSwEntry 2 } + +sdbDevOutSwScheduled OBJECT-TYPE + SYNTAX + INTEGER { + idle(0), + scheduled(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A one indicates pending activity; the switch delay has not yet + expired." + ::= { sdbDevOutSwEntry 3 } + +sdbDevOutSwUnlock OBJECT-TYPE + SYNTAX + INTEGER { + locked(0), + unlocked(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Switching and rebooting is unlocked for 10 seconds by writing a 1." + ::= { sdbDevOutSwEntry 4 } + +sdbDevOutSwIndividualOutletDelay OBJECT-TYPE + SYNTAX Second (0..65535) + UNITS "s" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Delay before an individual outlet switches on at power-up." + ::= { sdbDevOutSwEntry 5 } + +sdbDevOutSwReboot OBJECT-TYPE + SYNTAX + INTEGER { + idle(0), + reboot(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Reboot outlet relay if current state is on and outlet is unlocked; + The outlet will be turned on after 10 seconds." + ::= { sdbDevOutSwEntry 6 } + +sdbDevMeasuresTable OBJECT-TYPE + SYNTAX SEQUENCE OF SdbDevMeasuresEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table containing information of temperatures of devices connected to + the databus." + ::= { sdbDevSensor 1 } + +sdbDevMeasuresEntry OBJECT-TYPE + SYNTAX SdbDevMeasuresEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Device measures entry containing temperature information objects of a + particular databus device." + INDEX { sdbDevIdIndex } + ::= { sdbDevMeasuresTable 1 } + +SdbDevMeasuresEntry ::= + SEQUENCE { + sdbDevMsIntTemperature CentiCelsius, + sdbDevMsExtTemperature CentiCelsius, + sdbDevMsIntTemperaturePeak CentiCelsius, + sdbDevMsExtTemperaturePeak CentiCelsius + } + +sdbDevMsIntTemperature OBJECT-TYPE + SYNTAX CentiCelsius + UNITS "degrees Celsius" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Actual internal device temperature in deg C" + ::= { sdbDevMeasuresEntry 1 } + +sdbDevMsExtTemperature OBJECT-TYPE + SYNTAX CentiCelsius + UNITS "degrees Celsius" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Actual external device temperature sensor in deg C." + ::= { sdbDevMeasuresEntry 2 } + +sdbDevMsIntTemperaturePeak OBJECT-TYPE + SYNTAX CentiCelsius + UNITS "degrees Celsius" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Peak internal device temperature since last reset of alerts." + ::= { sdbDevMeasuresEntry 3 } + +sdbDevMsExtTemperaturePeak OBJECT-TYPE + SYNTAX CentiCelsius + UNITS "degrees Celsius" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Peak external device temperature since last reset of alerts." + ::= { sdbDevMeasuresEntry 4 } + +sdbDevSnsTable OBJECT-TYPE + SYNTAX SEQUENCE OF SdbDevSnsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table containing information of sensors of devices connected to the + databus." + ::= { sdbDevSensor 2 } + +sdbDevSnsEntry OBJECT-TYPE + SYNTAX SdbDevSnsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Sensors entry containing objects of a sensor of a particular databus + device. + Note that this table has two indexes. sdbDevIdIndex to identify a + particular device and sdbDevSnsIndex to identify a particular sensor + of the device identified by sdbDevIdIndex." + INDEX { + sdbDevIdIndex, + sdbDevSnsIndex + } + ::= { sdbDevSnsTable 1 } + +SdbDevSnsEntry ::= + SEQUENCE { + sdbDevSnsIndex Integer32, + sdbDevSnsType DisplayString, + sdbDevSnsValue CentiValue, + sdbDevSnsName DisplayString + } + +sdbDevSnsIndex OBJECT-TYPE + SYNTAX Integer32 (1..16) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A unique value for each sensor. Its value ranges between 1 and the + value of sdbDevCfSensors." + ::= { sdbDevSnsEntry 1 } + +sdbDevSnsType OBJECT-TYPE + SYNTAX DisplayString (SIZE(1)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Type of connected sensor. + T = Temperature (C) + H = Humidity (%) + I = dry switch contact" + ::= { sdbDevSnsEntry 2 } + +sdbDevSnsValue OBJECT-TYPE + SYNTAX CentiValue (0..327680) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Value of connected sensor" + ::= { sdbDevSnsEntry 3 } + +sdbDevSnsName OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..6)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "User definable name for sensors." + ::= { sdbDevSnsEntry 4 } + +-- --------------------------------------------------------------------------------------------- +sdbDevPerformanceTable OBJECT-TYPE + SYNTAX SEQUENCE OF SdbDevPerformanceEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table containing information of sensors of devices connected to the + databus." + ::= { sdbDevPerformance 1 } + +sdbDevPerformanceEntry OBJECT-TYPE + SYNTAX SdbDevPerformanceEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Performance counters of a particular databus device. + Note that this table has two indexes. sdbDevIdIndex to identify a + particular device and sdbDevPerformanceIndex to identify a particular counter + of the device identified by sdbDevIdIndex." + INDEX { + sdbDevIdIndex, + sdbDevPerformanceIndex + } + ::= { sdbDevPerformanceTable 1 } + +SdbDevPerformanceEntry ::= + SEQUENCE { + sdbDevPerformanceIndex Integer32, + sdbDevPerformanceValue Integer32, + sdbDevPerformanceMax Integer32, + sdbDevPerformanceLimit Integer32, + sdbDevPerformanceName DisplayString + } + +sdbDevPerformanceIndex OBJECT-TYPE + SYNTAX Integer32 (1..16) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A unique value for each counter. Its value ranges between 1 and 16." + ::= { sdbDevPerformanceEntry 1 } + +sdbDevPerformanceValue OBJECT-TYPE + SYNTAX Integer32 (0..16777215) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Value of counter" + ::= { sdbDevPerformanceEntry 2 } + +sdbDevPerformanceMax OBJECT-TYPE + SYNTAX Integer32 (0..16777215) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Max of counter" + ::= { sdbDevPerformanceEntry 3 } + +sdbDevPerformanceLimit OBJECT-TYPE + SYNTAX Integer32 (0..16777215) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Limit of counter" + ::= { sdbDevPerformanceEntry 4 } + +sdbDevPerformanceName OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..12)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "User definable name for counter." + ::= { sdbDevPerformanceEntry 5 } + +-- --------------------------------------------------------------------------------------------- + +sdbDevPerformanceResetTable OBJECT-TYPE + SYNTAX SEQUENCE OF SdbDevPerformanceResetEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table containing the last reset reason of the device" + ::= { sdbDevPerformance 2 } + +sdbDevPerformanceResetEntry OBJECT-TYPE + SYNTAX SdbDevPerformanceResetEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Setting entry containing settings objects of a particular databus + device." + INDEX { sdbDevIdIndex } + ::= { sdbDevPerformanceResetTable 1 } + +SdbDevPerformanceResetEntry ::= + SEQUENCE { + sdbDevPerformanceResetReason DisplayString, + sdbDevResetUptime Unsigned32 + } + +sdbDevPerformanceResetReason OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..64)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Last reset reason." + ::= { sdbDevPerformanceResetEntry 1 } + +sdbDevResetUptime OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Uptime before last reset" + ::= { sdbDevPerformanceResetEntry 2 } + +-- --------------------------------------------------------------------------------------------- + +sdbDevSsDeviceStatusCodeChanged NOTIFICATION-TYPE + STATUS current + DESCRIPTION + "Device status code changed. + + OBJECTS { + sdbDevSsDeviceStatusCode + }" + ::= { sdbMIBNotifications 1 } + +sdbDevSsTemperatureAlertDetected NOTIFICATION-TYPE + STATUS current + DESCRIPTION + "Temperature alert detected. + + Internal temperature alert: + OBJECTS { + sdbDevSsTemperatureAlert, + sdbDevMsIntTemperature, + sdbDevMsIntTemperaturePeak + } + + External analog temperature alert: + OBJECTS { + sdbDevSsTemperatureAlert, + sdbDevMsExtTemperature, + sdbDevMsExtTemperaturePeak + } + + External digital temperature alert: + OBJECTS { + sdbDevSsTemperatureAlert, + sdbDevSnsValue + }" + ::= { sdbMIBNotifications 2 } + +sdbDevSsInputCurrentAlertDetected NOTIFICATION-TYPE + STATUS current + DESCRIPTION + "Input current alert detected. + + OBJECTS { + sdbDevSsInputCurrentAlert, + sdbDevInActualCurrent + }" + ::= { sdbMIBNotifications 3 } + +sdbDevSsOutletCurrentAlertDetected NOTIFICATION-TYPE + STATUS current + DESCRIPTION + "Outlet current alert detected. + + OBJECTS { + sdbDevSsOutletCurrentAlert, + sdbDevOutMtActualCurrent + }" + ::= { sdbMIBNotifications 4 } + +sdbDevSsInputVoltageAlertDetected NOTIFICATION-TYPE + STATUS current + DESCRIPTION + "Input voltage alert detected. + + OBJECTS { + sdbDevSsInputVoltageAlert, + sdbDevInActualVoltage + }" + ::= { sdbMIBNotifications 5 } + +sdbDevSsOutletCurrentDropAlertDetected NOTIFICATION-TYPE + STATUS current + DESCRIPTION + "Outlet current drop alert detected. + + OBJECTS { + sdbDevSsOutletCurrentDropAlert, + sdbDevOutMtActualCurrent + }" + ::= { sdbMIBNotifications 6 } + +sdbDevSsInputCurrentDropAlertDetected NOTIFICATION-TYPE + STATUS current + DESCRIPTION + "Input current drop alert detected. + + OBJECTS { + sdbDevSsInputCurrentDropAlert, + sdbDevInActualCurrent + }" + ::= { sdbMIBNotifications 7 } + +sdbDevSsSensorChangeAlertDetected NOTIFICATION-TYPE + STATUS current + DESCRIPTION + "Sensor channel change alert detected. + + OBJECTS { + sdbDevSsSensorChangeAlert + }" + ::= { sdbMIBNotifications 8 } + +sdbMgmtStsRingStateChanged NOTIFICATION-TYPE + STATUS current + DESCRIPTION + "Ring state changed. + + Ring state changded to open: + OBJECTS { + sdbMgmtStsRingState, + sdbMgmtStsRingBreachIndex + } + + Ring state changded to closed: + OBJECTS { + sdbMgmtStsRingState + }" + ::= { sdbMIBNotifications 9 } + +sdbDevSsOutletVoltageDropAlertDetected NOTIFICATION-TYPE + STATUS current + DESCRIPTION + "Outlet voltage drop alert detected. + + OBJECTS { + sdbDevSsOutletVoltageDropAlert, + sdbDevOutMtActualVoltage + }" + ::= { sdbMIBNotifications 10 } + + +sdbMIBCompliance MODULE-COMPLIANCE + STATUS current + DESCRIPTION + "The requirements for conformance to the SCHLEIFENBAUER-DATABUS-MIB." + MODULE SCHLEIFENBAUER-DATABUS-MIB + GROUP sdbMIBNotificationGroup + DESCRIPTION + "The notification group." + GROUP sdbMIBDevSensorGroup + DESCRIPTION + "The sensors group." + GROUP sdbMIBDevOutGroup + DESCRIPTION + "The outlet group." + GROUP sdbMIBDevOutMtGroup + DESCRIPTION + "The outletMetering group." + GROUP sdbMIBDevOutSwGroup + DESCRIPTION + "The outletSwitched group." + GROUP sdbMIBDevInGroup + DESCRIPTION + "The inputMeasures group." + GROUP sdbMIBDevStGroup + DESCRIPTION + "The settings group." + GROUP sdbMIBDevSsGroup + DESCRIPTION + "The systemStatus group." + GROUP sdbMIBDevCfGroup + DESCRIPTION + "The configuration group." + GROUP sdbMIBDevIdGroup + DESCRIPTION + "The identification group." + GROUP sdbMIBDevRsGroup + DESCRIPTION + "resettable attributes in device" + GROUP sdbMIBMgmtStatusGroup + DESCRIPTION + "The databus management status group." + GROUP sdbMIBMgmtControlGroup + DESCRIPTION + "The databus management control group." + GROUP sdbMIBDevPerformanceGroup + DESCRIPTION + "The databus management control group." + ::= { sdbMIBCompliances 1 } + +sdbMIBNotificationGroup NOTIFICATION-GROUP + NOTIFICATIONS { + sdbDevSsDeviceStatusCodeChanged, + sdbDevSsTemperatureAlertDetected, + sdbDevSsInputCurrentAlertDetected, + sdbDevSsOutletCurrentAlertDetected, + sdbDevSsInputVoltageAlertDetected, + sdbDevSsOutletCurrentDropAlertDetected, + sdbDevSsInputCurrentDropAlertDetected, + sdbDevSsSensorChangeAlertDetected, + sdbMgmtStsRingStateChanged, + sdbDevSsOutletVoltageDropAlertDetected + } + STATUS current + DESCRIPTION + "A collection of notifications." + ::= { sdbMIBGroups 1 } + +sdbMIBDevIdGroup OBJECT-GROUP + OBJECTS { + sdbDevIdSPDMVersion, + sdbDevIdFirmwareVersion, + sdbDevIdSalesOrderNumber, + sdbDevIdProductId, + sdbDevIdSerialNumber, + sdbDevIdHardwareAddress, + sdbDevIdUnitAddress, + sdbDevIdName, + sdbDevIdLocation, + sdbDevIdVanityTag, + sdbDevIdMacAddress, + sdbDevIdBuildNumber, + sdbDevIdDeviceType, + sdbDevIdLocateUnit + } + STATUS current + DESCRIPTION + "A collection of objects providing identification information about the + device." + ::= { sdbMIBGroups 3 } + +sdbMIBDevCfGroup OBJECT-GROUP + OBJECTS { + sdbDevCfPhases, + sdbDevCfOutletsTotal, + sdbDevCfOutletsSwitched, + sdbDevCfOutletsMetered, + sdbDevCfMaximumLoad, + sdbDevCfSensors + } + STATUS current + DESCRIPTION + "A collection of objects providing configuration information about the + device." + ::= { sdbMIBGroups 4 } + +sdbMIBDevSsGroup OBJECT-GROUP + OBJECTS { + sdbDevSsDeviceStatusCode, + sdbDevSsTemperatureAlert, + sdbDevSsInputCurrentAlert, + sdbDevSsOutletCurrentAlert, + sdbDevSsInputVoltageAlert, + sdbDevSsOutletCurrentDropAlert, + sdbDevSsInputCurrentDropAlert, + sdbDevSsSensorChangeAlert, + sdbDevSsOutletVoltageDropAlert + } + STATUS current + DESCRIPTION + "A collection of objects providing status information about the + device." + ::= { sdbMIBGroups 5 } + +sdbMIBDevRsGroup OBJECT-GROUP + OBJECTS { + sdbDevRsResetAlerts, + sdbDevRsResetPeaksAndDips, + sdbDevRsReboot, + sdbDevRsZeroInputKWhSubtotal, + sdbDevRsZeroOutletKWhSubtotal + } + STATUS current + DESCRIPTION + "Groups resettable attributes op the device." + ::= { sdbMIBGroups 6 } + +sdbMIBDevStGroup OBJECT-GROUP + OBJECTS { + sdbDevStAutoResetAlerts, + sdbDevStExtendedNames, + sdbDevStPeakDuration, + sdbDevStLocalAlertReset, + sdbDevStFixedOutletDelay, + sdbDevStPowerSaverMode, + sdbDevStOutletPowerUpMode, + sdbDevStMaximumTemperature, + sdbDevStDisplayOrientation, + sdbDevStCurrentDropDetection, + sdbDevStUsbMode + } + STATUS current + DESCRIPTION + "A collection of objects providing the actual settings about the + device." + ::= { sdbMIBGroups 7 } + +sdbMIBDevInGroup OBJECT-GROUP + OBJECTS { + sdbDevInKWhTotal, + sdbDevInKWhSubtotal, + sdbDevInPowerFactor, + sdbDevInActualCurrent, + sdbDevInPeakCurrent, + sdbDevInActualVoltage, + sdbDevInMinVoltage, + sdbDevInPowerVoltAmpere, + sdbDevInPowerWatt, + sdbDevInMaxAmps, + sdbDevInCTRatio, + sdbDevInName, + sdbDevInZeroKWhSubtotal + } + STATUS current + DESCRIPTION + "A collection of objects providing the actual input measurements of the + device." + ::= { sdbMIBGroups 8 } + +sdbMIBDevOutGroup OBJECT-GROUP + OBJECTS { + sdbDevOutName + } + STATUS current + DESCRIPTION + "A collection of objects providing the actual outlet measurements of + the device." + ::= { sdbMIBGroups 9 } + +sdbMIBDevOutMtGroup OBJECT-GROUP + OBJECTS { + sdbDevOutMtKWhTotal, + sdbDevOutMtKWhSubtotal, + sdbDevOutMtPowerFactor, + sdbDevOutMtActualCurrent, + sdbDevOutMtPeakCurrent, + sdbDevOutMtActualVoltage, + sdbDevOutMtMaxAmps, + sdbDevOutMtCTRatio, + sdbDevOutMtPowerVoltAmpere, + sdbDevOutMtPowerWatt + } + STATUS current + DESCRIPTION + "A collection of objects providing the actual outlet measurements of + the device." + ::= { sdbMIBGroups 10 } + +sdbMIBDevOutSwGroup OBJECT-GROUP + OBJECTS { + sdbDevOutSwCurrentState, + sdbDevOutSwScheduled, + sdbDevOutSwUnlock, + sdbDevOutSwIndividualOutletDelay, + sdbDevOutSwReboot + } + STATUS current + DESCRIPTION + "A collection of objects providing the actual outlet measurements of + the device." + ::= { sdbMIBGroups 11 } + +sdbMIBDevSensorGroup OBJECT-GROUP + OBJECTS { + sdbDevSnsType, + sdbDevSnsValue, + sdbDevSnsName, + sdbDevMsIntTemperature, + sdbDevMsExtTemperature, + sdbDevMsIntTemperaturePeak, + sdbDevMsExtTemperaturePeak + } + STATUS current + DESCRIPTION + "A collection of objects providing the actual environmental + measurements of the device." + ::= { sdbMIBGroups 12 } + +sdbMIBMgmtStatusGroup OBJECT-GROUP + OBJECTS { + sdbMgmtStsDevices, + sdbMgmtStsAddressableDevices, + sdbMgmtStsNewDevices, + sdbMgmtStsDuplicateDevices, + sdbMgmtStsRingState, + sdbMgmtStsRingBreachIndex + } + STATUS current + DESCRIPTION + "A collection of objects providing management status information about + the databus." + ::= { sdbMIBGroups 13 } + +sdbMIBMgmtControlGroup OBJECT-GROUP + OBJECTS { + sdbMgmtCtrlScan, + sdbMgmtCtrlRenumberAllFromN, + sdbMgmtCtrlRenumberZeros, + sdbMgmtCtrlDevUnitAddress, + sdbMgmtCtrlDevHardwareAddress, + sdbMgmtCtrlDevIsNew, + sdbMgmtCtrlDevIsDuplicate + } + STATUS current + DESCRIPTION + "A collection of objects providing management control information about + the databus." + ::= { sdbMIBGroups 14 } + +sdbMIBDevPerformanceGroup OBJECT-GROUP + OBJECTS { + sdbDevPerformanceValue, + sdbDevPerformanceMax, + sdbDevPerformanceLimit, + sdbDevPerformanceName, + sdbDevPerformanceResetReason, + sdbDevResetUptime + } + STATUS current + DESCRIPTION + "A collection of objects providing performance information about the MCU" + ::= { sdbMIBGroups 15 } + +END diff --git a/MIBS/schleifenbauer/SCHLEIFENBAUER-PRODUCTS-MIB b/MIBS/schleifenbauer/SCHLEIFENBAUER-PRODUCTS-MIB new file mode 100644 index 0000000..4153300 --- /dev/null +++ b/MIBS/schleifenbauer/SCHLEIFENBAUER-PRODUCTS-MIB @@ -0,0 +1,51 @@ +------------------------------------------------------------------------------- +-- +-- SCHLEIFENBAUER-PRODUCTS-MIB.txt: Schleifenbauer Product Object Identifier Assignments +-- +-- October 2015, Marco Veeneman +-- +-- Copyright (c) 2015 by Schleifenbauer Holding BV +-- All rights reserved. +-- +------------------------------------------------------------------------------- + +SCHLEIFENBAUER-PRODUCTS-MIB DEFINITIONS ::= BEGIN + +IMPORTS + MODULE-IDENTITY + FROM SNMPv2-SMI + schleifenbauerProducts, + schleifenbauerModules + FROM SCHLEIFENBAUER-SMI; + +schleifenbauerProductsMIB MODULE-IDENTITY + LAST-UPDATED + "201510230000Z" -- October 23th, 2015 + ORGANIZATION + "Schleifenbauer Engineering" + CONTACT-INFO + "Schleifenbauer Engineering + Alain Schuermans + Chief Technology Officer + Turnhoutseweg 22 + 5541 NX Reusel + The Netherlands + t. +31 73 5230256 + f. +31 73 5212383 + alain@schleifenbauer.eu + www.schleifenbauer.eu" + DESCRIPTION + "TODO: description. + + Copyright (c) 2015 by Schleifenbauer Products BV + " + REVISION + "201510230000Z" -- October 23th, 2015 + DESCRIPTION + "The initial revision of this MIB module" + ::= { schleifenbauerModules 2} + +hpdu OBJECT IDENTIFIER ::= { schleifenbauerProducts 1 } +dpm3 OBJECT IDENTIFIER ::= { schleifenbauerProducts 2 } + +END diff --git a/MIBS/schleifenbauer/SCHLEIFENBAUER-SMI b/MIBS/schleifenbauer/SCHLEIFENBAUER-SMI new file mode 100644 index 0000000..ca44c83 --- /dev/null +++ b/MIBS/schleifenbauer/SCHLEIFENBAUER-SMI @@ -0,0 +1,68 @@ +------------------------------------------------------------------------------- +-- +-- SCHLEIFENBAUER-DATABUS-MIB.txt: Schleifenbauer Enterprise Structure of Management Information +-- +-- October 2015, Marco Veeneman +-- +-- Copyright (c) 2015 by Schleifenbauer Holding BV +-- All rights reserved. +-- +------------------------------------------------------------------------------- + +SCHLEIFENBAUER-SMI DEFINITIONS ::= BEGIN + +IMPORTS + MODULE-IDENTITY, + OBJECT-IDENTITY, + enterprises + FROM SNMPv2-SMI; + +schleifenbauer MODULE-IDENTITY + LAST-UPDATED + "201510230000Z" -- October 23th, 2015 + ORGANIZATION + "Schleifenbauer Engineering" + CONTACT-INFO + "Schleifenbauer Engineering + Alain Schuermans + Chief Technology Officer + Rietwaard 15 + 5236 WC ‘s-Hertogenbosch + The Netherlands + t +31 (0)73 52 30256 + f +31 (0)73 521 23 83 + alain@schleifenbauer.eu + www.schleifenbauer.eu" + DESCRIPTION + "The Structure of Management Information for the Schleifenbauer + enterprise. + + Copyright (c) 2015 by Schleifenbauer Products BV" + REVISION + "201510230000Z" -- October 23th, 2015 + DESCRIPTION + "The initial revision of this MIB module" + ::= { enterprises 31034 } + +schleifenbauerProducts OBJECT-IDENTITY + STATUS current + DESCRIPTION + "schleifenbauerProducts is the root OBJECT IDENTIFIER from which + sysObjectId values are assigned. Acutal values are defined in + SCHLEIFENBAUER-PRODUCTS-MIB." + ::= { schleifenbauer 11 } + +schleifenbauerMgmt OBJECT-IDENTITY + STATUS current + DESCRIPTION + "schleifenbauerMgmt is the main subtree for new mib development." + ::= { schleifenbauer 12 } + +schleifenbauerModules OBJECT-IDENTITY + STATUS current + DESCRIPTION + "schleifenbauerModules provides a root object identifier from which + MODULE-IDENTITY values may be assigned." + ::= { schleifenbauer 13 } + +END |