diff options
| author | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
|---|---|---|
| committer | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
| commit | 98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch) | |
| tree | 9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/rs/RS-XX8000-DVB-TX-MIB | |
| download | mibs-main.tar.gz mibs-main.zip | |
Diffstat (limited to 'MIBS/rs/RS-XX8000-DVB-TX-MIB')
| -rw-r--r-- | MIBS/rs/RS-XX8000-DVB-TX-MIB | 7049 |
1 files changed, 7049 insertions, 0 deletions
diff --git a/MIBS/rs/RS-XX8000-DVB-TX-MIB b/MIBS/rs/RS-XX8000-DVB-TX-MIB new file mode 100644 index 0000000..2f57141 --- /dev/null +++ b/MIBS/rs/RS-XX8000-DVB-TX-MIB @@ -0,0 +1,7049 @@ +-- ***************************************************************************** +-- ***************************************************************************** +-- ** +-- ** COPYRIGHT (c) 2006 Rohde & Schwarz GmbH & Co. KG +-- ** Muehldorfstrasse 15 +-- ** R & S D-81671 Muenchen +-- ** +-- ***************************************************************************** +-- ** +-- ** MODULE RS-XX8000-DVB-TX-MIB +-- ** +-- ** DESCRIPTION Rohde & Schwarz SNMP +-- ** +-- ** HISTORY +-- ** +-- ** 2006-11-28 hue - initial version +-- ** 2007-03-08 hue - added low power, sorted groups +-- ** 2007-07-11 sr - added cmdTxDelayTimeExcAutomatic, +-- ** cmdTxDelayTimeOstAutomatic, +-- ** cmdExcTypeLossOfInput, +-- ** cmdOstMaxOutletTempThreshold, +-- ** forwardPowerOstA, forwardPowerOstB, +-- ** reflectedPowerOstA, reflectedPowerOstB, +-- ** renamed ostRackTable to ostTable, +-- ** ostRackEntry to ostEntry, +-- ** added ostRackAmp... nodes +-- ** added productInfoTable, rfProbesTable +-- ** defined alarm class for txAutomaticExcChanged, +-- ** txAutomaticOstChanged +-- ** added groupProductInfo, groupAmpMeasureValues, +-- ** groupRfProbes, groupSingleTxLPNoNetCCU, +-- ** groupAlarmSingleTxLPNoNetCCU, +-- ** rsXx8000DVBSingleTxLPNoNetCCU +-- ** 2007-08-09 kp - expansion of ProductInfoTable +-- ** 2007-09-10 sr - remove forwardPowerOstA and reflectedPowerOstA +-- ** from groupSingleTxMP and groupDualDriveMP +-- ** 2007-12-07 sr - cmdExcSFNStaticDelay to FloatingPoint +-- ** cmdExcSFNDeviationTime changed range +-- ** - new exciter commands for RfOutput, RfIqAdjust and Precorrection +-- ** - rename prodInfoDeviceNameIdx to prodInfoModuleIdx and +-- ** prodInfoDeviceName to prodInfoModuleName +-- ** using TC ProdInfoModuleNameTv with a new value for netCCU +-- ** - rename txNetCCUBoardTemperatureWarning to +-- ** txNetCCUBoardTemperatureFault +-- ** - new OBJECT-GROUPs groupExciterStatus and groupExciterPrecorrection +-- ** 2008-03-31 sr - change range of cmdTxDelayTimeExcAutomatic and +-- ** cmdTxDelayTimeOstAutomatic to 1..60 +-- ** ks - SLx extension +-- ** 2008-05-05 sr - cmdExcReferenceSource with value internGPS +-- ** 2008-06-11 ks - cmdExcInput1Source, cmdExcInput2Source added +-- ** 2008-07-23 sr - new SLx parameters: cmdExcTimeScheduler, configurationTable and +-- ** timeSchedulerTable +-- ** - new SFN Delay parameters in exciterStatusTable +-- ** 2008-08-26 ks - rfProbesNetCCURfProbe1, rfProbesNetCCURfProbe2 read-only +-- ** - cmdTxParametersetReSave obsolete +-- ** 2008-07-29 hu - changed TextualConvention for Exciter LogbookEntryMessages +-- ** 2008-09-10 sr - new rackTable +-- ** - new txRackRfWarning, txRackRfFault, txRackReflectionWarning, +-- ** txRackReflectionFault +-- ** - new groupIndependentRacks +-- ** 2008-10-08 sr - cmdExcFrequency and configFrequency range up to 1500 MHz +-- ** 2008-10-23 ks - new: cmdExcInpAutoReadyAfterChangeOv, +-- ** txExcInputAutomaticSwitchReady, txExcInputAutomaticChangedOver +-- ** 2008-12-12 sr - rfProbeConfigurationLabel obsolete +-- ** - txRackExtCoolingWarning renamed to txRackGpiWarning +-- ** - txRackExtCoolingFault renamed to txRackGpiFault +-- ** 2009-01-06 sr - rfProbeCalibrationSetGain, rfProbeCalibrationSetOffset +-- ** 2009-02-12 sr - InputSource with value tp +-- ** - new groupExcCommandsAdditional +-- ** 2009-03-30 ks - txRackProbeNotCalibrated added +-- ** - txParamSetSubDeviceDiffers obsoleted +-- ** 2009-05-28 ks -information for additional (external) power supply added +-- ** - txRackRfOn, txRackRfOk, txRackTemperatureWarning added +-- ** 2009-06-17 ks - object groups, notification groups and +-- ** module compliances reorganized +-- ** 2009-06-26 ks - consideration of face-lift configuration in module compliances +-- ** - measured values for power supply added +-- ** - cmdExcInputAutoSwitch obsoleted +-- ** - conditional groupDummyLoadRF added +-- ** 2009-07-16 ks - additional values for reserve concept 'backup exciter' +-- ** 2009-09-10 ks - cmdTxSystemMode added +-- ** - traps for TX mode switch over added +-- ** 2009-10-08 ks - txRackOvervoltProtectWarning added +-- ** - cmdExcInputAutoSwitch obsoleted +-- ** 2009-11-13 ks - ostRackAmpDeltaPhase, ostRackAmpCmdDeltaPhase added +-- ** 2009-11-26 ks - cmdExcRfFailLimit, cmdExcRfWarningLimit added +-- ** 2009-11-27 ks - cmdExcInputFailDelayTime added +-- ** 2009-11-30 ks - cmdExcMonitoringOutput, cmdExcOcxoAdjust added +-- ** 2009-12-01 ks - configRxFrequency, configInputSource added +-- ** 2009-12-04 ks - configuration2Table added +-- ** 2009-12-07 ks - excStatusNominalPower added +-- ** 2009-12-18 ks - txExcRfOk added +-- ** 2010-01-12 ks - excStatusVSWR added +-- ** 2010-01-29 ks - txNetCCUBoardTemperatureFault deprecated, +-- ** txNetCCUBoardTemperatureWarning added +-- ** 2010-02-02 ks - cmdExcExpectInputReserve, txExcInputReseveMissing added +-- ** 2010-20-04 ks - cmdExcMuteCondition added +-- ** 2010-05-21 ks - cmdTxRfSwitch added +-- ** 2010-10-13 ks - cmdExcEnablePcrReset, cmdExcTimeForDailyPcrReset added +-- ** 2010-12-02 ks - excStatusAmplifierControl, excStatusReqDataRateHP, +-- ** excStatusReqDataRateLP added +-- ** 2011-02-28 ks - Amplifier status for Sx801 added. +-- ** 2011-05-12 ks - cmdExcFailDelayMode, excStatusFailDelay added +-- ** 2012-09-03 ks - sx801AmplifierTable measured values added +-- ** 2012-11-01 ks - Hierarchical input is no longer supported. +-- ***************************************************************************** +-- ***************************************************************************** + + RS-XX8000-DVB-TX-MIB DEFINITIONS ::= BEGIN + + IMPORTS + rsXx8000, eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, + indexRack, indexAmplifier, rsXx8000MibModule, ReadableString, FloatingPoint, + LogbookEntryMessagesNetCCU, LogbookEntryMessagesOST, LogbookEntrySlope, EventMaxEntryNumber, SwitchOnOff, + Trigger, EventMask, EventPriority, EventState, EventClass, + IndexRack, IndexAmplifier, IndexAB, LogbookMaxEntryNumber, ProdInfoModuleNameTv, + EqualizerCalibrationState, TvStandard, LogbookEntryMessagesExcTv, InputSource, TimeOfDay, + Sx801AmplifierState, FailDelayMode, FailDelayStatus + FROM RS-XX8000-COMMON-MIB + OBJECT-GROUP, MODULE-COMPLIANCE, NOTIFICATION-GROUP + FROM SNMPv2-CONF + Integer32, OBJECT-TYPE, MODULE-IDENTITY, OBJECT-IDENTITY, NOTIFICATION-TYPE + FROM SNMPv2-SMI + DateAndTime, TruthValue, RowStatus + FROM SNMPv2-TC; + + + rsXx8000DvbTxMibModule MODULE-IDENTITY + LAST-UPDATED "201211010800Z" -- November 01, 2012 at 08:00 GMT + ORGANIZATION + "Rohde&Schwarz GmbH & Co. KG" + CONTACT-INFO + "Torsten Huebscher + Department 7TS2 + Broadcasting Division + Muehldorfstrasse 15 + 81671 Munich, Germany + torsten.huebscher@rohde-schwarz.com" + DESCRIPTION + "This MIB defines transmitting systems from Rohde & Schwarz. + + Use this MIB if your system meets the following requirements: + - series XX8000 (NetCCU800), + - DVB, + - transmitter reserve concept SingleTx, DualDrive, + Active Reserve or Passive Reserve. + + The following MIBs are related to this: + - RS-COMMON-MIB - mandatory for this MIB + - RS-XX8000-COMMON-MIB - mandatory for this MIB" + REVISION "201211010800Z" -- November 01, 2012 at 08:00 GMT + DESCRIPTION + "Hierarchical input is no longer supported." + REVISION "201209030800Z" -- September 03, 2012 at 08:00 GMT + DESCRIPTION + "sx801AmplifierTable measured values added" + REVISION "201105120800Z" -- May 12, 2011 at 08:00 GMT + DESCRIPTION + "cmdExcFailDelayMode, excStatusFailDelay added" + REVISION "201102280800Z" -- February 28, 2011 at 08:00 GMT + DESCRIPTION + "Amplifier status for Sx801 added." + REVISION "201012020800Z" -- December 02, 2010 at 08:00 GMT + DESCRIPTION + "excStatusAmplifierControl, excStatusReqDataRateHP, + excStatusReqDataRateLP added" + REVISION "201010130800Z" -- October 13, 2010 at 08:00 GMT + DESCRIPTION + "cmdExcEnablePcrReset, cmdExcTimeForDailyPcrReset added" + REVISION "201005210800Z" -- May 21, 2010 at 08:00 GMT + DESCRIPTION + "cmdTxRfSwitch added" + REVISION "201004160800Z" -- April 16, 2010 at 08:00 GMT + DESCRIPTION + "cmdExcMuteCondition added" + REVISION "201002020800Z" -- February 02, 2010 at 08:00 GMT + DESCRIPTION + "cmdExcExpectInputReserve, txExcInputReseveMissing added" + REVISION "201001290800Z" -- January 29, 2010 at 08:00 GMT + DESCRIPTION + "txNetCCUBoardTemperatureFault deprecated, + txNetCCUBoardTemperatureWarning added" + REVISION "201001120800Z" -- January 12, 2010 at 08:00 GMT + DESCRIPTION + "excStatusVSWR added" + REVISION "200912180800Z" -- December 18, 2009 at 08:00 GMT + DESCRIPTION + "txExcRfOk added" + REVISION "200911260800Z" -- November 26, 2009 at 08:00 GMT + DESCRIPTION + "cmdExcRfFailLimit, cmdExcRfWarningLimit, + cmdExcInputFailDelayTime, cmdExcMonitoringOutput, + cmdExcOcxoAdjust, configRxFrequency, + configInputSource, configuration2Table, + excStatusNominalPower added" + REVISION "200911130800Z" -- November 13, 2009 at 08:00 GMT + DESCRIPTION + "ostRackAmpDeltaPhase, ostRackAmpCmdDeltaPhase added" + REVISION "200910080800Z" -- October 08, 2009 at 08:00 GMT + DESCRIPTION + "txRackOvervoltProtectWarning added + cmdExcInputAutoSwitch obsoleted" + REVISION "200909100800Z" -- September 10, 2009 at 08:00 GMT + DESCRIPTION + "cmdTxSystemMode added + traps for TX mode switch over added" + REVISION "200907160800Z" -- July 16, 2009 at 08:00 GMT + DESCRIPTION + "additional values for reserve concept 'backup exciter'" + REVISION "200906260800Z" -- June 26, 2009 at 08:00 GMT + DESCRIPTION + "consideration of face-lift configuration in module compliances, + measured values for power supply added, + cmdExcInputAutoSwitch obsoleted, + conditional groupDummyLoadRF added" + REVISION "200906170900Z" -- June 17, 2009 at 09:00 GMT + DESCRIPTION + "object groups, notification groups and module compliances reorganized" + REVISION "200905280900Z" -- May 28, 2009 at 09:00 GMT + DESCRIPTION + "information for additional (external) power supply added + txRackRfOn, txRackRfOk, txRackTemperatureWarning added" + REVISION "200903300900Z" -- March 30, 2009 at 09:00 GMT + DESCRIPTION + "txRackProbeNotCalibrated added + txParamSetSubDeviceDiffers obsoleted" + REVISION "200902121500Z" -- February 12, 2009 at 15:00 GMT + DESCRIPTION + "- InputSource with value tp + - new groupExcCommandsAdditional" + REVISION "200901290900Z" -- January 29, 2009 at 09:00 GMT + DESCRIPTION + "MODULE COMPLIANCE rsXx8000DVBReEquip" + REVISION "200901061600Z" -- January 06, 2009 at 16:00 GMT + DESCRIPTION + "rfProbeCalibrationSetGain, rfProbeCalibrationSetOffset" + REVISION "200812121430Z" -- December 12, 2008 at 14:30 GMT + DESCRIPTION + "rfProbeConfigurationLabel obsolete + txRackExtCoolingWarning renamed to txRackGpiWarning + txRackExtCoolingFault renamed to txRackGpiFault" + REVISION "200810230800Z" -- October 23, 2008 at 08:00 GMT + DESCRIPTION + "cmdExcInpAutoReadyAfterChangeOv + txExcInputAutomaticSwitchReady, txExcInputAutomaticChangedOver" + REVISION "200810081030Z" -- October 08, 2008 at 10:30 GMT + DESCRIPTION + "cmdExcFrequency and configFrequency range up to 1500 MHz" + REVISION "200809101500Z" -- September 10, 2008 at 15:00 GMT + DESCRIPTION + "new rackTable + new txRackRfWarning, txRackRfFault, txRackReflectionWarning, + txRackReflectionFault + new groupIndependentRacks" + REVISION "200808291000Z" -- August 29, 2008 at 10:00 GMT + DESCRIPTION + "changed TextualConvention for Exciter LogbookEntryMessages" + REVISION "200808260900Z" -- August 26, 2008 at 09:00 GMT + DESCRIPTION + "- rfProbesNetCCURfProbe1, rfProbesNetCCURfProbe2 read-only + - cmdTxParametersetReSave obsolete" + REVISION "200807231000Z" -- July 23, 2008 at 10:00 GMT + DESCRIPTION + "- new SLx parameters: cmdExcTimeScheduler, configurationTable and + timeSchedulerTable + - new SFN Delay parameters in exciterStatusTable" + REVISION "200805050930Z" -- May 05, 2008 at 09:30 GMT + DESCRIPTION + "- cmdExcReferenceSource with value internGPS + - cmdExcInput1Source, cmdExcInput2Source added" + REVISION "200803311100Z" -- March 31, 2008 at 11:00 GMT + DESCRIPTION + "- change range of cmdTxDelayTimeExcAutomatic and + cmdTxDelayTimeOstAutomatic to 1..60 + - adds cmdExcTransmitterType, cmdExcOutputPower + excPrecUserState, excPrecFactoryState, excPrecRestoreCurrentSettings, excPrecRestoreAllSettings" + REVISION "200712071700Z" -- December 07, 2007 at 17:00 GMT + DESCRIPTION + "- cmdExcSFNStaticDelay to FloatingPoint + cmdExcSFNDeviationTime changed range + - new exciter commands for RfOutput, RfIqAdjust and Precorrection + - rename prodInfoDeviceNameIdx to prodInfoModuleIdx and + prodInfoDeviceName to prodInfoModuleName + using TC ProdInfoModuleNameTv with a new value for netCCU + - rename txNetCCUBoardTemperatureWarning to + txNetCCUBoardTemperatureFault + - new OBJECT-GROUPs groupExciterStatus and groupExciterPrecorrection" + REVISION "200709101100Z" -- September 10, 2007 at 11:00 GMT + DESCRIPTION + "remove forwardPowerOstA and reflectedPowerOstA from groupSingleMP and groupDualDriveMP" + REVISION "200708091400Z" -- August 09, 2007 at 14:00 GMT + DESCRIPTION + "Expansion of ProductInfoTable" + REVISION "200707111600Z" -- July 11, 2007 at 16:00 GMT + DESCRIPTION + "added cmdTxDelayTimeExcAutomatic, + cmdTxDelayTimeOstAutomatic, + cmdExcTypeLossOfInput, + cmdOstMaxOutletTempThreshold, + forwardPowerOstA, forwardPowerOstB, + reflectedPowerOstA, reflectedPowerOstB, + renamed ostRackTable to ostTable, + ostRackEntry to ostEntry, + added ostRackAmp... nodes + added productInfoTable, rfProbesTable + defined alarm class for txAutomaticExcChanged, + txAutomaticOstChanged + added groupProductInfo, groupAmpMeasureValues, + groupRfProbes, groupSingleTxLPNoNetCCU, + groupAlarmSingleTxLPNoNetCCU, + rsXx8000DVBSingleTxLPNoNetCCU" + REVISION "200703081000Z" -- March 08, 2007 at 10:00 GMT + DESCRIPTION + "- Added LowPower + - Sorted groups" + REVISION "200612211000Z" -- December 21, 2006 at 10:00 GMT + DESCRIPTION + "This is the initial version." + ::= { rsXx8000MibModule 3 } + + + + +-- +-- Node definitions +-- + + rsXx8000DvbTx OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Xx8000 DVB transmitter." + ::= { rsXx8000 4 } + + +-- ***************************************************************************** +-- ** object definitions +-- ***************************************************************************** + rsXx8000DvbTxObjs OBJECT IDENTIFIER ::= { rsXx8000DvbTx 1 } + + + commandsTxTable OBJECT-TYPE + SYNTAX SEQUENCE OF CommandsTxEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains important commands for the transmitter." + ::= { rsXx8000DvbTxObjs 1 } + + + commandsTxEntry OBJECT-TYPE + SYNTAX CommandsTxEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry for a designated transmitter and device." + INDEX { cmdDeviceIdx } + ::= { commandsTxTable 1 } + + + CommandsTxEntry ::= + SEQUENCE { + cmdTxResetSumFault + Trigger, + cmdTxParametersetLoad + Integer32, + cmdTxParametersetSave + Integer32, + cmdTxParametersetReSave + Trigger, + cmdTxOperationModeProgram + SwitchOnOff, + cmdTxOperationModeReserve + SwitchOnOff, + cmdTxOpModeExcAutomatic + SwitchOnOff, + cmdTxOpModeOstAutomatic + SwitchOnOff, + cmdTxPreselectExciter + IndexAB, + cmdTxPreselectOutputstage + INTEGER, + cmdTxDelayTimeExcAutomatic + Integer32, + cmdTxDelayTimeOstAutomatic + Integer32, + cmdTxRfSwitch + INTEGER, + cmdTxSystemMode + TvStandard, + cmdTxProgramExciterPrio + SwitchOnOff, + cmdTxChangeOver + Trigger, + cmdTxSwitchPosition + INTEGER, + cmdDeviceIdx + IndexAB, + cmdExcOpModeInputAutomatic + SwitchOnOff, + cmdExcPreselectInput + INTEGER, + cmdExcMode + INTEGER, + cmdExcNetworkMode + INTEGER, + cmdExcTPSSource + INTEGER, + cmdExcEnableCellID + SwitchOnOff, + cmdExcTxAddress + Integer32, + cmdExcTxAutomatic + SwitchOnOff, + cmdExcInputAutoSwitch + SwitchOnOff, + cmdExcInputSeamless + SwitchOnOff, + cmdExcInputPriority + INTEGER, + cmdExcInputCheckTimeForward + Integer32, + cmdExcInputCheckTimeSwitchback + Integer32, + cmdExcInputMuteOnFail + INTEGER, + cmdExcInputManualPreseletionHP1 + INTEGER, + cmdExcInputManualPreseletionHP2 + INTEGER, + cmdExcInputManualPreseletionLP1 + INTEGER, + cmdExcInputManualPreseletionLP2 + INTEGER, + cmdExcTPSManualBandwidth + INTEGER, + cmdExcTPSManualFFTLength + INTEGER, + cmdExcTPSManualGuardInterval + INTEGER, + cmdExcTPSManualConstellation + INTEGER, + cmdExcTPSManualAlpha + INTEGER, + cmdExcTPSManualCellID + Integer32, + cmdExcTPSManualInterleaver + INTEGER, + cmdExcTPSManualCoderateHP + INTEGER, + cmdExcTPSManualCoderateLP + INTEGER, + cmdExcTPSManualTimeSlicingHP + SwitchOnOff, + cmdExcTPSManualTimeSlicingLP + SwitchOnOff, + cmdExcTPSManualFECHP + SwitchOnOff, + cmdExcTPSManualFECLP + SwitchOnOff, + cmdExcSFNStaticDelay + FloatingPoint, + cmdExcSFNDeviationTime + Integer32, + cmdExcFrequency + Integer32, + cmdExcReferenceSource + INTEGER, + cmdExcMuteOnPPSFail + INTEGER, + cmdExcMuteOnReferenceFail + INTEGER, + cmdExcRefFailDelayTime + Integer32, + cmdExcTypeLossOfInput + INTEGER, + cmdExcRfOutput + SwitchOnOff, + cmdExcRfOutputRegulation + SwitchOnOff, + cmdExcRfOutputManualRfLevel + FloatingPoint, + cmdExcRfOutputAttenuation + Integer32, + cmdExcRfOutputRfSlope + FloatingPoint, + cmdExcRfOutputModulationSlope + FloatingPoint, + cmdExcRfIqAdjustStart + INTEGER, + cmdExcRfIqAdjustTestsignal + SwitchOnOff, + cmdExcRfIqAdjustBiasCoarseI + Integer32, + cmdExcRfIqAdjustBiasCoarseQ + Integer32, + cmdExcRfIqAdjustBiasFineI + Integer32, + cmdExcRfIqAdjustBiasFineQ + Integer32, + cmdExcRfIqAdjustGainI + Integer32, + cmdExcRfIqAdjustGainQ + Integer32, + cmdExcRfIqAdjustPhase + FloatingPoint, + cmdExcInput1Source + InputSource, + cmdExcInput2Source + InputSource, + cmdExcInpAutoReadyAfterChangeOv + SwitchOnOff, + cmdExcInputFailDelayTime + Integer32, + cmdExcTransmitterType + INTEGER, + cmdExcTimeScheduler + SwitchOnOff, + cmdExcMuteCondition + INTEGER, + cmdExcRfWarningLimit + FloatingPoint, + cmdExcRfFailLimit + FloatingPoint, + cmdExcOutputPower + FloatingPoint, + cmdOstRefVoltageVision + FloatingPoint, + cmdOstMaxOutletTempThreshold + Integer32, + cmdExcMonitoringOutput + INTEGER, + cmdExcOcxoAdjust + Integer32, + cmdExcExpectInputReserve + SwitchOnOff, + cmdExcEnablePcrReset + SwitchOnOff, + cmdExcTimeForDailyPcrReset + TimeOfDay, + cmdExcFailDelayMode + FailDelayMode + } + + cmdTxResetSumFault OBJECT-TYPE + SYNTAX Trigger + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Reset all faults (in all modules) of the transmitter. + + You reset a designated transmitter (NetCCU, Exciters, Outputstages). + An equivalent would be pressing RESET at this transmitters frontpanel. + + A GET will always return idle(1). A SET idle(1) will return NO_ERROR without doing anything." + ::= { commandsTxEntry 1 } + + + cmdTxParametersetLoad OBJECT-TYPE + SYNTAX Integer32 (1..8) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This loads the desired parameter set." + ::= { commandsTxEntry 2 } + + + cmdTxParametersetSave OBJECT-TYPE + SYNTAX Integer32 (1..8) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This saves the current settings to a designated parameter set." + ::= { commandsTxEntry 3 } + + + cmdTxParametersetReSave OBJECT-TYPE + SYNTAX Trigger + MAX-ACCESS read-write + STATUS obsolete + DESCRIPTION + "This saves the changes to the current parameter set." + ::= { commandsTxEntry 4 } + + + cmdTxOperationModeProgram OBJECT-TYPE + SYNTAX SwitchOnOff + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This switches the program path of the transmitter on/off." + ::= { commandsTxEntry 5 } + + + cmdTxOperationModeReserve OBJECT-TYPE + SYNTAX SwitchOnOff + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This switches the reserve path of the transmitter on/off." + ::= { commandsTxEntry 6 } + + + cmdTxOpModeExcAutomatic OBJECT-TYPE + SYNTAX SwitchOnOff + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This switches the exciter automatic on/off." + ::= { commandsTxEntry 7 } + + + cmdTxOpModeOstAutomatic OBJECT-TYPE + SYNTAX SwitchOnOff + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This switches the outputstage automatic on/off. + + This paramter is only available for systems with an automatic output switch." + ::= { commandsTxEntry 8 } + + + cmdTxPreselectExciter OBJECT-TYPE + SYNTAX IndexAB + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This sets exciterA or exciterB to program path (antenna) of the transmitter." + ::= { commandsTxEntry 9 } + + + cmdTxPreselectOutputstage OBJECT-TYPE + SYNTAX INTEGER + { + outputstageA(1), + outputstageB(2), + bothToAntenna(3), + bothToDummyLoad(4) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This sets + - outputstageA or + - outputstageB or + - both + to program path (antenna) of the transmitter, + or it sets both to dummyload. + + The settings bothToAntenna(3) and bothToDummyLoad(4) are only settable + for ActiveReserve systems. + + This paramter is only available for systems with an automatic output switch." + ::= { commandsTxEntry 10 } + + + cmdTxDelayTimeExcAutomatic OBJECT-TYPE + SYNTAX Integer32 (1..60) + UNITS "seconds" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This sets the exciter automatic delay time." + ::= { commandsTxEntry 11 } + + + cmdTxDelayTimeOstAutomatic OBJECT-TYPE + SYNTAX Integer32 (1..60) + UNITS "seconds" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This sets the outputstage automatic delay time. + + This paramter is only available for systems with an automatic output switch." + ::= { commandsTxEntry 12 } + + + cmdTxRfSwitch OBJECT-TYPE + SYNTAX INTEGER + { + antenna(1), + dummyLoad(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "RF switch for single-ended systems." + ::= { commandsTxEntry 13 } + + + cmdTxSystemMode OBJECT-TYPE + SYNTAX TvStandard + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object gives you the possibility of switching the TV standard + of a whole system with NetCCU with only one command. + Not applicable for N+1 or NTx systems. + The value 'test' cannot be written." + ::= { commandsTxEntry 15 } + + + cmdTxProgramExciterPrio OBJECT-TYPE + SYNTAX SwitchOnOff + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enables/Disables priority usage of program exciter" + ::= { commandsTxEntry 20 } + + + cmdTxChangeOver OBJECT-TYPE + SYNTAX Trigger + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Performs a change over" + ::= { commandsTxEntry 21 } + + + cmdTxSwitchPosition OBJECT-TYPE + SYNTAX INTEGER + { + undefined(1), + controlExcOnAmp(2), + programExcOnAmp(3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Shows the actual switch position. + The program exciter is connected to input 1 (RF IN 1), + the control exciter is connected to input 2 (RF IN 2) of the base amplifier." + ::= { commandsTxEntry 22 } + + + cmdDeviceIdx OBJECT-TYPE + SYNTAX IndexAB + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This column is used to show parameters for both exiters, if you have + dualdrive transmitters." + ::= { commandsTxEntry 30 } + + + cmdExcOpModeInputAutomatic OBJECT-TYPE + SYNTAX SwitchOnOff + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Activates/deactivates the input automatic. + If input automatic is active + and a loss of input signal is detected on the current input + the reserve input will be used instead." + ::= { commandsTxEntry 31 } + + + cmdExcPreselectInput OBJECT-TYPE + SYNTAX INTEGER + { + input1(1), + input2(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This sets the preselection of a transmitters input." + ::= { commandsTxEntry 32 } + + + cmdExcMode OBJECT-TYPE + SYNTAX INTEGER + { + dvbT(1), + dvbH(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Switch between DVB-T and DVB-H." + ::= { commandsTxEntry 33 } + + + cmdExcNetworkMode OBJECT-TYPE + SYNTAX INTEGER + { + mfn(1), + sfn(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Switch between Single Frequency Networks (SFN) and + Multiple Frequency Networks (MFN)." + ::= { commandsTxEntry 34 } + + + cmdExcTPSSource OBJECT-TYPE + SYNTAX INTEGER + { + manualPresets(1), + mip(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Transmitted TPS parameters can be adjusted manually inside + the transmitter or automatically via MIP from the SFN adaptor." + ::= { commandsTxEntry 35 } + + + cmdExcEnableCellID OBJECT-TYPE + SYNTAX SwitchOnOff + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This enables the Cell ID insertion. + The length indicator will be adjusted." + ::= { commandsTxEntry 36 } + + + cmdExcTxAddress OBJECT-TYPE + SYNTAX Integer32 (0..65535) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This is the unique address of the transmitter + to reference specific settings in the MIP." + ::= { commandsTxEntry 37 } + + + cmdExcTxAutomatic OBJECT-TYPE + SYNTAX SwitchOnOff + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This enables Tx specific parameters from the + MIP data caroussel (e.g. time offset, frequency offset)." + ::= { commandsTxEntry 38 } + + + cmdExcInputAutoSwitch OBJECT-TYPE + SYNTAX SwitchOnOff + MAX-ACCESS read-write + STATUS deprecated + DESCRIPTION + "Activates/deactivates the input automatic. + If input automatic is active + and a loss of input signal is detected on the current input + the reserve input will be used instead. + + This object is deprecated. It's recommended to use cmdExcOpModeInputAutomatic instead." + ::= { commandsTxEntry 39 } + + + cmdExcInputSeamless OBJECT-TYPE + SYNTAX SwitchOnOff + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "If the datastreams on both inputs are syncronised a seamless switch is possible. + With this parameter the seamless switch can be suppressed to enable a check of the input automatic." + ::= { commandsTxEntry 40 } + + + cmdExcInputPriority OBJECT-TYPE + SYNTAX INTEGER + { + equal(1), + prior(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Equal: There are no differences between both inputs. + If a failure on the current input is detected it will be switched to the reserve input. + It stays there until the reserve shows a failure. + Prior: Whenever possible a certain input shall be used. + If a failure is detected the reserve will be used as short as possible." + ::= { commandsTxEntry 41 } + + + cmdExcInputCheckTimeForward OBJECT-TYPE + SYNTAX Integer32 (0..600) + UNITS "seconds" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This time has to elapse before the current input switches + to the reserve input." + ::= { commandsTxEntry 42 } + + + cmdExcInputCheckTimeSwitchback OBJECT-TYPE + SYNTAX Integer32 (0..600) + UNITS "seconds" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This time has to elapse before the automatic switches back + from the reserve to a preselected input. + This value has no effect if the priority is set to equal." + ::= { commandsTxEntry 43 } + + + cmdExcInputMuteOnFail OBJECT-TYPE + SYNTAX INTEGER + { + mute(1), + noMute(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "If a loss of input signal is detected, the exciter mutes." + ::= { commandsTxEntry 44 } + + + cmdExcInputManualPreseletionHP1 OBJECT-TYPE + SYNTAX INTEGER + { + auto(1), + asi(2), + smpte(3) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The data format of the input can be detected + automatically or can be set manually to ASI or SMPTE." + ::= { commandsTxEntry 45 } + + + cmdExcInputManualPreseletionHP2 OBJECT-TYPE + SYNTAX INTEGER + { + auto(1), + asi(2), + smpte(3) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The data format of the input can be detected + automatically or can be set manually to ASI or SMPTE." + ::= { commandsTxEntry 46 } + + + cmdExcInputManualPreseletionLP1 OBJECT-TYPE + SYNTAX INTEGER + { + auto(1), + asi(2), + smpte(3) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The data format of the input can be detected + automatically or can be set manually to ASI or SMPTE." + ::= { commandsTxEntry 47 } + + + cmdExcInputManualPreseletionLP2 OBJECT-TYPE + SYNTAX INTEGER + { + auto(1), + asi(2), + smpte(3) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The data format of the input can be detected + automatically or can be set manually to ASI or SMPTE." + ::= { commandsTxEntry 48 } + + + cmdExcTPSManualBandwidth OBJECT-TYPE + SYNTAX INTEGER + { + mhz5(1), + mhz6(2), + mhz7(3), + mhz8(4) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The bandwidth used by the RF channel." + ::= { commandsTxEntry 49 } + + + cmdExcTPSManualFFTLength OBJECT-TYPE + SYNTAX INTEGER + { + k2(1), + k8(2), + k4(3) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The used FFT length (depends on the DVB network)." + ::= { commandsTxEntry 50 } + + + cmdExcTPSManualGuardInterval OBJECT-TYPE + SYNTAX INTEGER + { + oneOf32(1), + oneOf16(2), + oneOf8(3), + oneOf4(4) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The Guard interval affects the error correction in multipath receiving situations. + A long Guard Interval reduces the amount of payload data." + ::= { commandsTxEntry 51 } + + + cmdExcTPSManualConstellation OBJECT-TYPE + SYNTAX INTEGER + { + qpsk(1), + qam16(2), + qam64(3) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This parameter sets the modulation mode." + ::= { commandsTxEntry 52 } + + + cmdExcTPSManualAlpha OBJECT-TYPE + SYNTAX INTEGER + { + noHierarchy(1), + one(2), + two(3), + four(4) + } + MAX-ACCESS read-write + STATUS obsolete + DESCRIPTION + "An alpha greater than noHierarchy(1) enables the hierarchical coding mode." + ::= { commandsTxEntry 53 } + + + cmdExcTPSManualCellID OBJECT-TYPE + SYNTAX Integer32 (0..65535) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Via Cell ID the receiver knows the current network." + ::= { commandsTxEntry 54 } + + + cmdExcTPSManualInterleaver OBJECT-TYPE + SYNTAX INTEGER + { + indepth(1), + nat(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enables the bit interleaver for hierarchical coding" + ::= { commandsTxEntry 55 } + + + cmdExcTPSManualCoderateHP OBJECT-TYPE + SYNTAX INTEGER + { + oneOf2(1), + twoOf3(2), + threeOf4(3), + fiveOf6(4), + sevenOf8(5) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The Code Rate sets the ratio between payload and error correction information." + ::= { commandsTxEntry 56 } + + + cmdExcTPSManualCoderateLP OBJECT-TYPE + SYNTAX INTEGER + { + oneOf2(1), + twoOf3(2), + threeOf4(3), + fiveOf6(4), + sevenOf8(5) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The Code Rate sets the ratio between payload and error correction information." + ::= { commandsTxEntry 57 } + + + cmdExcTPSManualTimeSlicingHP OBJECT-TYPE + SYNTAX SwitchOnOff + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enables the time slicing for hierarchical coding." + ::= { commandsTxEntry 58 } + + + cmdExcTPSManualTimeSlicingLP OBJECT-TYPE + SYNTAX SwitchOnOff + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enables the time slicing for hierarchical coding." + ::= { commandsTxEntry 59 } + + + cmdExcTPSManualFECHP OBJECT-TYPE + SYNTAX SwitchOnOff + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enables the forward error correction (FEC) for hierarchical coding." + ::= { commandsTxEntry 60 } + + + cmdExcTPSManualFECLP OBJECT-TYPE + SYNTAX SwitchOnOff + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enables the forward error correction (FEC) for hierarchical coding." + ::= { commandsTxEntry 61 } + + + cmdExcSFNStaticDelay OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Microseconds" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "A constant adjustable delay for tuning a SFN (-999999.9 ... 999999.9)." + ::= { commandsTxEntry 62 } + + + cmdExcSFNDeviationTime OBJECT-TYPE + SYNTAX Integer32 (1..100) + UNITS "Microseconds" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Leap In Time. + This parameter sets the deviation in time when a readjustment + of the dynamic delay is necessary." + ::= { commandsTxEntry 63 } + + + cmdExcFrequency OBJECT-TYPE + SYNTAX Integer32 (47000000..1500000000) + UNITS "Hertz" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This is the RF frequency." + ::= { commandsTxEntry 64 } + + + cmdExcReferenceSource OBJECT-TYPE + SYNTAX INTEGER + { + intern(1), + extern5Mhz(2), + extern10Mhz(3), + extern1PPS(4), + internGPS(5) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The Source of the reference signal. + The value internGPS is not valid for SX800." + ::= { commandsTxEntry 65 } + + + cmdExcMuteOnPPSFail OBJECT-TYPE + SYNTAX INTEGER + { + off(1), + onlyAtStartup(2), + afterFailDelayTime(3) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Select the behaviour if the external second pulse is not available." + ::= { commandsTxEntry 66 } + + + cmdExcMuteOnReferenceFail OBJECT-TYPE + SYNTAX INTEGER + { + off(1), + onlyAtStartup(2), + afterFailDelayTime(3) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Select the behaviour if the external reference is not available." + ::= { commandsTxEntry 67 } + + + cmdExcRefFailDelayTime OBJECT-TYPE + SYNTAX Integer32 (0..24) + UNITS "Hours" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Adjusts the time after the RF will be muted in case of a reference problem. + Zero hours means react immediately." + ::= { commandsTxEntry 68 } + + + cmdExcTypeLossOfInput OBJECT-TYPE + SYNTAX INTEGER + { + warning(1), + fault(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "If the input signal is lost, either a warning or a fault can be generated. + If you select fault here, a switchover to the reserve exciter will be executed + when input signal is lost." + ::= { commandsTxEntry 69 } + + + cmdExcRfOutput OBJECT-TYPE + SYNTAX SwitchOnOff + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Turns on/switches off the output signal. This switch takes the same effect as the switch on the frontpanel of the exciter." + ::= { commandsTxEntry 70 } + + + cmdExcRfOutputRegulation OBJECT-TYPE + SYNTAX SwitchOnOff + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Turns on/switches off the automatic output level regulation." + ::= { commandsTxEntry 71 } + + + cmdExcRfOutputManualRfLevel OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Percent" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Adjusts the RF level (0.0 ... 100.0). The value relates to an attenuation of 0 dB." + ::= { commandsTxEntry 72 } + + + cmdExcRfOutputAttenuation OBJECT-TYPE + SYNTAX Integer32 (0..9) + UNITS "dB" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Activates internal attenuators to reduce the output level of the exciter. + Adjustable in steps of 3 dB only." + ::= { commandsTxEntry 73 } + + + cmdExcRfOutputRfSlope OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Percent" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Adjusts a slope in the RF signal (-50.0 ... 50.0)." + ::= { commandsTxEntry 74 } + + + cmdExcRfOutputModulationSlope OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Percent" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Modulation slope (-50.0 ... 50.0)." + ::= { commandsTxEntry 75 } + + + cmdExcRfIqAdjustStart OBJECT-TYPE + SYNTAX INTEGER + { + break(1), + start(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Starts the automatic IQ adjustment. It works for the current used local 1 frequency and lasts up to 5 minutes. In this time the output will be muted. During the adjustment no transmitter parameter shall be changed. Break will stop the automatic immediately. The IQ modulator looses its adjustment! + Read values mean idle(1) and started(2)." + ::= { commandsTxEntry 77 } + + + cmdExcRfIqAdjustTestsignal OBJECT-TYPE + SYNTAX SwitchOnOff + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Generates a test signal to adjust the IQ modulation. It is necessary to disconnect the rf-cable to the output stages." + ::= { commandsTxEntry 78 } + + + cmdExcRfIqAdjustBiasCoarseI OBJECT-TYPE + SYNTAX Integer32 (-1023..1023) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Adjusts the offset for I in huge steps." + ::= { commandsTxEntry 79 } + + + cmdExcRfIqAdjustBiasCoarseQ OBJECT-TYPE + SYNTAX Integer32 (-1023..1023) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Adjusts the offset for Q in huge steps." + ::= { commandsTxEntry 80 } + + + cmdExcRfIqAdjustBiasFineI OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Adjusts the offset for I in small steps." + ::= { commandsTxEntry 81 } + + + cmdExcRfIqAdjustBiasFineQ OBJECT-TYPE + SYNTAX Integer32 (-32767..32767) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Adjusts the offset for Q in small steps." + ::= { commandsTxEntry 82 } + + + cmdExcRfIqAdjustGainI OBJECT-TYPE + SYNTAX Integer32 (0..255) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Adjusts the gain for I in small steps." + ::= { commandsTxEntry 83 } + + + cmdExcRfIqAdjustGainQ OBJECT-TYPE + SYNTAX Integer32 (0..255) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Adjusts the gain for Q in small steps." + ::= { commandsTxEntry 84 } + + + cmdExcRfIqAdjustPhase OBJECT-TYPE + SYNTAX FloatingPoint + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Adjusts the phase between I and Q (-14.000 ... 14.000)." + ::= { commandsTxEntry 85 } + + + cmdExcInput1Source OBJECT-TYPE + SYNTAX InputSource + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Source for input 1." + ::= { commandsTxEntry 86 } + + + cmdExcInput2Source OBJECT-TYPE + SYNTAX InputSource + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Source for input 2." + ::= { commandsTxEntry 87 } + + + cmdExcInpAutoReadyAfterChangeOv OBJECT-TYPE + SYNTAX SwitchOnOff + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Input automatic ready after change over." + ::= { commandsTxEntry 88 } + + + cmdExcInputFailDelayTime OBJECT-TYPE + SYNTAX Integer32 (0..600) + UNITS "Seconds" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The time between detecting a loss of input signal and displaying a failure." + ::= { commandsTxEntry 89 } + + + cmdExcTransmitterType OBJECT-TYPE + SYNTAX INTEGER + { + atv(1), + dvb(2), + atsc(3) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "the TV standard of the transmitter + The transmitter is rebooted automatically when the TV standard is + changed. Signal processing is also switched over." + ::= { commandsTxEntry 90 } + + + cmdExcTimeScheduler OBJECT-TYPE + SYNTAX SwitchOnOff + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "If on, the time scheduler controls the tx type. When switching on the scheduler + it may instantly set the correct TV standard and reboot the device." + ::= { commandsTxEntry 91 } + + + cmdExcMuteCondition OBJECT-TYPE + SYNTAX INTEGER + { + onAllFaults(1), + notBeforeSyncLoss(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "When notBeforeSyncLoss(2) is selected, + it relativizes the cmdExcInputMuteOnFail setting mute(1): + If a DVB receiver is the last valid input, an existing transport stream, + even if it is faulty shall not be muted. + + Only for SLx/Sx801" + ::= { commandsTxEntry 92 } + + + cmdExcRfWarningLimit OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "dB" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Warning limit for the RF control. + min: -15.0, max: 0.0" + ::= { commandsTxEntry 97 } + + + cmdExcRfFailLimit OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "dB" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Fault limit for the RF control. + min: -15.0, max: 0.0" + ::= { commandsTxEntry 98 } + + + cmdExcOutputPower OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "W" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "amplifier output power + 0 ... 400 W" + ::= { commandsTxEntry 99 } + + + cmdOstRefVoltageVision OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Percent" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This adjusts the output power of the amplifier. + This value is settable with maximal 1 position after point (example 11.2)." + ::= { commandsTxEntry 100 } + + + cmdOstMaxOutletTempThreshold OBJECT-TYPE + SYNTAX Integer32 (45..65) + UNITS "Degree Celsius" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This sets the threshold for the outlet temperature." + ::= { commandsTxEntry 101 } + + + cmdExcMonitoringOutput OBJECT-TYPE + SYNTAX INTEGER + { + off(1), + reference10MHz(2), + generated1PPS(3), + kHz1(4), + pulse1PPS(5) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Selects which signal appears at the monitoring output." + ::= { commandsTxEntry 110 } + + + cmdExcOcxoAdjust OBJECT-TYPE + SYNTAX Integer32 (0..65535) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Adjusts the frequency of the internal 10 MHz reference. + This value only takes effect if the reference source 'internal' is selected." + ::= { commandsTxEntry 111 } + + + cmdExcExpectInputReserve OBJECT-TYPE + SYNTAX SwitchOnOff + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "If on(1) the warning txExcInputReseveMissing will be generated + in case second input is missing." + ::= { commandsTxEntry 112 } + + + cmdExcEnablePcrReset OBJECT-TYPE + SYNTAX SwitchOnOff + MAX-ACCESS read-write + STATUS obsolete + DESCRIPTION + "Enables/disables daily PCR resets. + This option is valid only in MFN operation. + The reset time is given in cmdExcTimeForDailyPcrReset." + ::= { commandsTxEntry 113 } + + + cmdExcTimeForDailyPcrReset OBJECT-TYPE + SYNTAX TimeOfDay + MAX-ACCESS read-write + STATUS obsolete + DESCRIPTION + "Sets the time of day for daily PCR reset." + ::= { commandsTxEntry 114 } + + + cmdExcFailDelayMode OBJECT-TYPE + SYNTAX FailDelayMode + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Condition when the fail delay time is used." + ::= { commandsTxEntry 115 } + + + summaryInfo OBJECT IDENTIFIER ::= { rsXx8000DvbTxObjs 2 } + + + summaryFaultTx OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This indicates a summary fault of the transmitter. + true(1) --> summary fault + false(2) --> no summary fault + + There is a fault of at least one module (e.g. Exciter) which causes this summary fault. + + An equivalent would be the LED Fault at the transmitters frontpanel." + ::= { summaryInfo 1 } + + + summaryWarningTx OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This indicates a summary warning of the transmitter. + true(1) --> summary warning + false(2) --> no summary warning + + There is a fault of at least one module (e.g. Exciter) which causes this summary warning. + + An equivalent would be the LED Warning at the transmitters frontpanel." + ::= { summaryInfo 2 } + + + localModeTx OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This indicates the local/remote-mode of the transmitter. + true(1) --> local + false(2) --> remote + + The transmitter is eigther in local-mode or in remote-mode. + For security reasons it is not possible to set this value! + + An equivalent would the LED Local at the transmitters frontpanel." + ::= { summaryInfo 3 } + + + rfOnTx OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The RF is present for the corresponding transmitter." + ::= { summaryInfo 4 } + + + forwardPower OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Watt" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The measured forwarded power [W] of the transmitter. + For Active Reserve systems it is the sum of both outputstages." + ::= { summaryInfo 5 } + + + reflectedPower OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Watt" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The measured reflected power [W] of the transmitter. + For Active Reserve systems it is the sum of both outputstages. + + Not available for lowpower systems." + ::= { summaryInfo 6 } + + + summaryFaultExcA OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This indicates a summary fault of exciter." + ::= { summaryInfo 7 } + + + summaryFaultOstA OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This indicates a summary fault of outputstage." + ::= { summaryInfo 8 } + + + summaryFaultExcB OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This indicates a summary fault of exciter." + ::= { summaryInfo 9 } + + + summaryFaultOstB OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This indicates a summary fault of outputstage." + ::= { summaryInfo 10 } + + + exciterAutomaticReady OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The Exciter Automatic is Ready. + In case of any fault on one exciter, there will be a switchover to the other exciter." + ::= { summaryInfo 11 } + + + exciterAutomaticChanged OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The Exciter Automatic has changed. + There was a fault on one exciter which lead to this changeover." + ::= { summaryInfo 12 } + + + exciterAutomaticFault OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The Exciter Automatic is faulty. + In case of any fault on one exciter, there will be no switchover to the other exciter, + because of this fault." + ::= { summaryInfo 13 } + + + outputstageAutomaticReady OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The Outputstage Automatic is Ready. + In case of any fault on one outputstage, there will be a switchover to the other outputstage. + + This paramter is only available for systems with an automatic output switch." + ::= { summaryInfo 14 } + + + outputstageAutomaticChanged OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The Outputstage Automatic has changed. + There was a fault on one outputstage which lead to this changeover. + + This paramter is only available for systems with an automatic output switch." + ::= { summaryInfo 15 } + + + outputstageAutomaticFault OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The Outputstage Automatic is faulty. + In case of any fault on one outputstage, there will be no switchover to the other outputstage, + because of this fault. + + This paramter is only available for systems with an automatic output switch." + ::= { summaryInfo 16 } + + + noConnectionExcA OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "No Connection between NetCCU and Exciter." + ::= { summaryInfo 17 } + + + noConnectionOstA OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "No Connection between NetCCU and Outputstage." + ::= { summaryInfo 18 } + + + noConnectionExcB OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "No Connection between NetCCU and Exciter." + ::= { summaryInfo 19 } + + + noConnectionOstB OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "No Connection between NetCCU and Outputstage." + ::= { summaryInfo 20 } + + + activeExcA OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "ExciterA is currently active." + ::= { summaryInfo 21 } + + + activeOstA OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "OutputstageA is currently active." + ::= { summaryInfo 22 } + + + activeExcB OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "ExciterB is currently active." + ::= { summaryInfo 23 } + + + activeOstB OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "OutputstageB is currently active." + ::= { summaryInfo 24 } + + + forwardPowerOstA OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Watt" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The measured forwarded power [W] of the OutputstageA." + ::= { summaryInfo 25 } + + + reflectedPowerOstA OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Watt" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The measured reflected power [W] of the OutputstageA. + + Not available for lowpower systems." + ::= { summaryInfo 26 } + + + forwardPowerOstB OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Watt" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The measured forwarded power [W] of the OutputstageB." + ::= { summaryInfo 27 } + + + reflectedPowerOstB OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Watt" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The measured reflected power [W] of the OutputstageB. + + Not available for lowpower systems." + ::= { summaryInfo 28 } + + + powerSupply OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "volt" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Monitoring value of the output voltages of the power supply." + ::= { summaryInfo 29 } + + + additionalPowerSupply OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Shows whether the NetCCU has an additional (external) power supply." + ::= { summaryInfo 30 } + + + internalPowerSupply OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "volt" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Monitoring value of the output voltages of the internal power supply." + ::= { summaryInfo 31 } + + + externalPowerSupply OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "volt" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Monitoring value of the output voltages of the external power supply." + ::= { summaryInfo 32 } + + + detailedInfo OBJECT IDENTIFIER ::= { rsXx8000DvbTxObjs 3 } + + + excInputTable OBJECT-TYPE + SYNTAX SEQUENCE OF ExcInputEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table for more detailed information about the exciter. + These values are all read-only. For settings, refer to commands." + ::= { detailedInfo 2 } + + + excInputEntry OBJECT-TYPE + SYNTAX ExcInputEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry for a designated input channel." + INDEX { excInputExcIdx, excInputChannelIdx } + ::= { excInputTable 1 } + + + ExcInputEntry ::= + SEQUENCE { + excInputExcIdx + IndexAB, + excInputChannelIdx + Integer32, + excInputChannelName + INTEGER, + excInputConnected + TruthValue, + excInputSeamless + TruthValue, + excInputPreselected + TruthValue, + excInputActive + TruthValue, + excInputMipFail + TruthValue, + excInputBandwidth + INTEGER, + excInputFFTLength + INTEGER, + excInputGuardInterval + INTEGER, + excInputConstellation + INTEGER, + excInputAlpha + INTEGER, + excInputCellID + Integer32, + excInputInterleaver + INTEGER, + excInputCodeRate + INTEGER, + excInputPacketLength + Integer32, + excInputMeasuredDatarate + Integer32, + excInputRequiredDatarate + Integer32, + excInputMaximumDelay + Integer32 + } + + excInputExcIdx OBJECT-TYPE + SYNTAX IndexAB + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The index for exciterA (and exciterB if there are DualDrive systems)." + ::= { excInputEntry 1 } + + + excInputChannelIdx OBJECT-TYPE + SYNTAX Integer32 (1..6) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The index for the different input channels." + ::= { excInputEntry 2 } + + + excInputChannelName OBJECT-TYPE + SYNTAX INTEGER + { + hp1(1), + hp2(2), + lp1(3), + lp2(4), + activeHP(5), + activeLP(6) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This is the logical name for the index for the different input channels." + ::= { excInputEntry 3 } + + + excInputConnected OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The input channel is connected." + ::= { excInputEntry 4 } + + + excInputSeamless OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The input channel is in seamless mode." + ::= { excInputEntry 5 } + + + excInputPreselected OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The input channel is the preselected." + ::= { excInputEntry 6 } + + + excInputActive OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The input channel is active." + ::= { excInputEntry 7 } + + + excInputMipFail OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Input channel MIP fail." + ::= { excInputEntry 8 } + + + excInputBandwidth OBJECT-TYPE + SYNTAX INTEGER + { + mhz5(1), + mhz6(2), + mhz7(3), + mhz8(4) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The bandwidth used by the input channel." + ::= { excInputEntry 9 } + + + excInputFFTLength OBJECT-TYPE + SYNTAX INTEGER + { + k2(1), + k8(2), + k4(3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The used FFT length (depends on the DVB network)." + ::= { excInputEntry 10 } + + + excInputGuardInterval OBJECT-TYPE + SYNTAX INTEGER + { + oneOf32(1), + oneOf16(2), + oneOf8(3), + oneOf4(4) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The Guard interval affects the error correction in multipath receiving situations. + A long Guard Interval reduces the amount of payload data." + ::= { excInputEntry 11 } + + + excInputConstellation OBJECT-TYPE + SYNTAX INTEGER + { + qpsk(1), + qam16(2), + qam64(3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This parameter sets the modulation mode." + ::= { excInputEntry 12 } + + + excInputAlpha OBJECT-TYPE + SYNTAX INTEGER + { + noHierarchy(1), + one(2), + two(3), + four(4) + } + MAX-ACCESS read-only + STATUS obsolete + DESCRIPTION + "An alpha greater than zero enables the hierarchical coding mode." + ::= { excInputEntry 13 } + + + excInputCellID OBJECT-TYPE + SYNTAX Integer32 (0..65535) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Via Cell ID the receiver knows the current network." + ::= { excInputEntry 14 } + + + excInputInterleaver OBJECT-TYPE + SYNTAX INTEGER + { + indepth(1), + nat(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Enables the bit interleaver for hierarchical coding" + ::= { excInputEntry 15 } + + + excInputCodeRate OBJECT-TYPE + SYNTAX INTEGER + { + oneOf2(1), + twoOf3(2), + threeOf4(3), + fiveOf6(4), + sevenOf8(5) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Coderate can be set separately for HP and LP channel." + ::= { excInputEntry 16 } + + + excInputPacketLength OBJECT-TYPE + SYNTAX Integer32 (188..208) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The Packet length for the channel." + ::= { excInputEntry 17 } + + + excInputMeasuredDatarate OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The measured datarate of the input." + ::= { excInputEntry 18 } + + + excInputRequiredDatarate OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The required datarate of the input." + ::= { excInputEntry 19 } + + + excInputMaximumDelay OBJECT-TYPE + SYNTAX Integer32 (0..100000000) + UNITS "Nanoseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Period of time between the signal leaving the play-out center (MIP inserter) + and its regular transmission at the antenna. + This delay is set in the MIP inserter and serves as a basis + for all the transmitters in the SFN." + ::= { excInputEntry 20 } + + + ostTable OBJECT-TYPE + SYNTAX SEQUENCE OF OstEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The table of racks." + ::= { detailedInfo 3 } + + + ostEntry OBJECT-TYPE + SYNTAX OstEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A row (an entry) for one rack." + INDEX { ostIdx, ostRackIdx, ostRackAmpIdx } + ::= { ostTable 1 } + + + OstEntry ::= + SEQUENCE { + ostIdx + IndexAB, + ostRackIdx + IndexRack, + ostRackInletTemperature + FloatingPoint, + ostRackOutletTemperature + FloatingPoint, + ostRackAuxPowerSupply + FloatingPoint, + ostRackAmpIdx + IndexAmplifier, + ostRackAmpI1A + FloatingPoint, + ostRackAmpI2A + FloatingPoint, + ostRackAmpI3A + FloatingPoint, + ostRackAmpI4A + FloatingPoint, + ostRackAmpI1B + FloatingPoint, + ostRackAmpI2B + FloatingPoint, + ostRackAmpI3B + FloatingPoint, + ostRackAmpI4B + FloatingPoint, + ostRackAmpIDrv + FloatingPoint, + ostRackAmpUDc + FloatingPoint, + ostRackAmpIDc + FloatingPoint, + ostRackAmpUDcControl + FloatingPoint, + ostRackAmpUReg + FloatingPoint, + ostRackAmpPowerA + FloatingPoint, + ostRackAmpPowerB + FloatingPoint, + ostRackAmpPowerOut + FloatingPoint, + ostRackAmpPowerReflection + FloatingPoint, + ostRackAmpPowerReference + FloatingPoint, + ostRackAmpDeltaPhase + FloatingPoint, + ostRackAmpCmdDeltaPhase + FloatingPoint + } + + ostIdx OBJECT-TYPE + SYNTAX IndexAB + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The dedicated outputstage (A/B)." + ::= { ostEntry 1 } + + + ostRackIdx OBJECT-TYPE + SYNTAX IndexRack + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The rack number (1..10)." + ::= { ostEntry 2 } + + + ostRackInletTemperature OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Degree Celsius" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The inlet temperature." + ::= { ostEntry 3 } + + + ostRackOutletTemperature OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Degree Celsius" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The outlet temperature." + ::= { ostEntry 4 } + + + ostRackAuxPowerSupply OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Volt" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Control voltage of auxiliary power supply of the designated rack. + The value should be between 11.1 to 13.2 V." + ::= { ostEntry 5 } + + + ostRackAmpIdx OBJECT-TYPE + SYNTAX IndexAmplifier + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Amplifier Index" + ::= { ostEntry 400 } + + + ostRackAmpI1A OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Ampere" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The power amplifier module current (I_1A)." + ::= { ostEntry 401 } + + + ostRackAmpI2A OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Ampere" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The power amplifier module current (I_2A)." + ::= { ostEntry 402 } + + + ostRackAmpI3A OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Ampere" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The power amplifier module current (I_3A)." + ::= { ostEntry 403 } + + + ostRackAmpI4A OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Ampere" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The power amplifier module current (I_4A)." + ::= { ostEntry 404 } + + + ostRackAmpI1B OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Ampere" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The power amplifier module current (I_1B)." + ::= { ostEntry 405 } + + + ostRackAmpI2B OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Ampere" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The power amplifier module current (I_2B)." + ::= { ostEntry 406 } + + + ostRackAmpI3B OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Ampere" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The power amplifier module current (I_3B)." + ::= { ostEntry 407 } + + + ostRackAmpI4B OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Ampere" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The power amplifier module current (I_4B)." + ::= { ostEntry 408 } + + + ostRackAmpIDrv OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Ampere" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The driver module current (I_DRV)." + ::= { ostEntry 409 } + + + ostRackAmpUDc OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Volt" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The power amplifier supply voltage." + ::= { ostEntry 410 } + + + ostRackAmpIDc OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Ampere" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The power amplifier supply current." + ::= { ostEntry 411 } + + + ostRackAmpUDcControl OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Volt" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The power supply control voltage." + ::= { ostEntry 412 } + + + ostRackAmpUReg OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Volt" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The power amplifier AGC voltage." + ::= { ostEntry 413 } + + + ostRackAmpPowerA OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Volt" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The voltage power detector A." + ::= { ostEntry 414 } + + + ostRackAmpPowerB OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Volt" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The voltage power detector B." + ::= { ostEntry 415 } + + + ostRackAmpPowerOut OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Volt" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The voltage forward power detector." + ::= { ostEntry 416 } + + + ostRackAmpPowerReflection OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Volt" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The voltage reflected power detector." + ::= { ostEntry 417 } + + + ostRackAmpPowerReference OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Volt" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The reference voltage for output power." + ::= { ostEntry 418 } + + + ostRackAmpDeltaPhase OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Percent" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The measured phase delta for output power." + ::= { ostEntry 419 } + + + ostRackAmpCmdDeltaPhase OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Percent" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The phase delta setting for output power. + The range is -50.0% to 50.0%." + ::= { ostEntry 420 } + + + exciterStatusTable OBJECT-TYPE + SYNTAX SEQUENCE OF ExciterStatusEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Exciter status values." + ::= { detailedInfo 20 } + + + exciterStatusEntry OBJECT-TYPE + SYNTAX ExciterStatusEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A row (an entry) for one exciter." + INDEX { excStatusExcIdx } + ::= { exciterStatusTable 1 } + + + ExciterStatusEntry ::= + SEQUENCE { + excStatusExcIdx + IndexAB, + excStatusRfOutputAgcRegulation + FloatingPoint, + excStatusRfIqAdjustAuto + INTEGER, + excStatusRfIqAdjustLO1Frequency + FloatingPoint, + excStatusNominalPower + Integer32, + excStatusVSWR + FloatingPoint, + excStatusSfnDelayProcessing + FloatingPoint, + excStatusSfnDelayDynamic + FloatingPoint, + excStatusSfnDelayNetwork + FloatingPoint, + excStatusSfnDelayTxOffset + FloatingPoint, + excStatusSfnDelayMaximum + FloatingPoint, + excStatusSfnDelayTotal + FloatingPoint, + excStatusAmplifierControl + INTEGER, + excStatusReqDataRateHP + Integer32, + excStatusReqDataRateLP + Integer32, + excStatusFailDelay + FailDelayStatus + } + + excStatusExcIdx OBJECT-TYPE + SYNTAX IndexAB + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The dedicated exciter (A/B)." + ::= { exciterStatusEntry 3 } + + + excStatusRfOutputAgcRegulation OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Percent" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Shows the operating point of the RF regulator. The shown value should be around 50 per cent." + ::= { exciterStatusEntry 4 } + + + excStatusRfIqAdjustAuto OBJECT-TYPE + SYNTAX INTEGER + { + notAdjusted(1), + inProgress(2), + adjusted(3) + } + UNITS "Percent" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Automatic I/Q-Adjust." + ::= { exciterStatusEntry 5 } + + + excStatusRfIqAdjustLO1Frequency OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "MHz" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Modulator LO1." + ::= { exciterStatusEntry 6 } + + + excStatusNominalPower OBJECT-TYPE + SYNTAX Integer32 + UNITS "W" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Description." + ::= { exciterStatusEntry 7 } + + + excStatusVSWR OBJECT-TYPE + SYNTAX FloatingPoint + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Voltage Standing Wave Ratio" + ::= { exciterStatusEntry 9 } + + + excStatusSfnDelayProcessing OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The Minimum signal transmit time through the exciter. + This delay depends on the DVB transmission parameters." + ::= { exciterStatusEntry 13 } + + + excStatusSfnDelayDynamic OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The period of time by which signal processing is artificially delayed + so that the desired time of transmission is obtained." + ::= { exciterStatusEntry 14 } + + + excStatusSfnDelayNetwork OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The signal propagation time between the play-out center + (MIP inserter) and the exciter input. This delay depends + on the transmission path used." + ::= { exciterStatusEntry 15 } + + + excStatusSfnDelayTxOffset OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "An individual transmitter specific delay. It can be adjusted + via data carousel of the SFN adapter. It is true for a + specific transmitter address." + ::= { exciterStatusEntry 16 } + + + excStatusSfnDelayMaximum OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The period of time between the signal leaving the play-out center + (MIP inserter) and its regular transmission at the antenna. + This delay is set in the MIP inserter and serves as a basis for + all the transmitters in the SFN." + ::= { exciterStatusEntry 17 } + + + excStatusSfnDelayTotal OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The actual signal transit time through the exciter. + This is derived from the sum of static-, dynamic-, + offset- and processing delay." + ::= { exciterStatusEntry 18 } + + + excStatusAmplifierControl OBJECT-TYPE + SYNTAX INTEGER + { + on(1), + off(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Amplifier control status" + ::= { exciterStatusEntry 20 } + + + excStatusReqDataRateHP OBJECT-TYPE + SYNTAX Integer32 + UNITS "bit per seconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Required data rate on HP input + with respect to the current TPS settings." + ::= { exciterStatusEntry 30 } + + + excStatusReqDataRateLP OBJECT-TYPE + SYNTAX Integer32 + UNITS "bit per seconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Required data rate on LP input + with respect to the current TPS settings." + ::= { exciterStatusEntry 31 } + + + excStatusFailDelay OBJECT-TYPE + SYNTAX FailDelayStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Shows whether the fail delay time is qualified." + ::= { exciterStatusEntry 40 } + + + exciterPrecorrectionTable OBJECT-TYPE + SYNTAX SEQUENCE OF ExciterPrecorrectionEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Exciter status values." + ::= { detailedInfo 21 } + + + exciterPrecorrectionEntry OBJECT-TYPE + SYNTAX ExciterPrecorrectionEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A row (an entry) for one exciter." + INDEX { excPrecExcIdx } + ::= { exciterPrecorrectionTable 1 } + + + ExciterPrecorrectionEntry ::= + SEQUENCE { + excPrecExcIdx + IndexAB, + excPrecLinCorrection + SwitchOnOff, + excPrecLinAutomaticADE + INTEGER, + excPrecLinMaxAmplitudeRipple + FloatingPoint, + excPrecLinMaxGroupDelayRipple + Integer32, + excPrecLinAmplitudeRipple + FloatingPoint, + excPrecLinGroupDelayRipple + Integer32, + excPrecLinInputLevel + INTEGER, + excPrecLinAutomatic + INTEGER, + excPrecNonlinCorrection + SwitchOnOff, + excPrecNonlinAutomaticADE + INTEGER, + excPrecNonlinThresholdShoulders + FloatingPoint, + excPrecNonlinShoulderLeft + FloatingPoint, + excPrecNonlinShoulderRight + FloatingPoint, + excPrecNonlinInputLevel + INTEGER, + excPrecNonlinAutomatic + INTEGER, + excPrecUserState + EqualizerCalibrationState, + excPrecFactoryState + EqualizerCalibrationState, + excPrecRestoreCurrentSettings + INTEGER, + excPrecRestoreAllSettings + INTEGER + } + + excPrecExcIdx OBJECT-TYPE + SYNTAX IndexAB + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The dedicated exciter (A/B)." + ::= { exciterPrecorrectionEntry 3 } + + + excPrecLinCorrection OBJECT-TYPE + SYNTAX SwitchOnOff + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Switches on/turns off the linear precorrector." + ::= { exciterPrecorrectionEntry 4 } + + + excPrecLinAutomaticADE OBJECT-TYPE + SYNTAX INTEGER + { + manual(1), + automatic(2), + adaptive(3) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enables /disables the automatic precorrector. To get the ADE in work linear precorrection has to be switched on." + ::= { exciterPrecorrectionEntry 5 } + + + excPrecLinMaxAmplitudeRipple OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "dB" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Sets te maximum ripple for automatic amplitude correction (0.0 ... 2.0)." + ::= { exciterPrecorrectionEntry 6 } + + + excPrecLinMaxGroupDelayRipple OBJECT-TYPE + SYNTAX Integer32 (0..500) + UNITS "Nanoseconds" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Sets the maximum ripple for automatic group delay correction." + ::= { exciterPrecorrectionEntry 7 } + + + excPrecLinAmplitudeRipple OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "dB" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Shows the current amplitude ripple." + ::= { exciterPrecorrectionEntry 8 } + + + excPrecLinGroupDelayRipple OBJECT-TYPE + SYNTAX Integer32 + UNITS "Nanoseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Shows the current group delay ripple." + ::= { exciterPrecorrectionEntry 9 } + + + excPrecLinInputLevel OBJECT-TYPE + SYNTAX INTEGER + { + tooHigh(1), + ok(2), + tooLow(3), + failure(4) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Shows the state of the feedback signal from the measurement point between output stage and antenna." + ::= { exciterPrecorrectionEntry 10 } + + + excPrecLinAutomatic OBJECT-TYPE + SYNTAX INTEGER + { + disabled(1), + active(2), + calculate(3), + measure(4) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Shows if the automatic precorrector works properly." + ::= { exciterPrecorrectionEntry 11 } + + + excPrecNonlinCorrection OBJECT-TYPE + SYNTAX SwitchOnOff + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Switches on/turns off the nonlinear precorrector." + ::= { exciterPrecorrectionEntry 12 } + + + excPrecNonlinAutomaticADE OBJECT-TYPE + SYNTAX INTEGER + { + manual(1), + automatic(2), + adaptive(3) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enables /disables the automatic precorrector. To get the ADE in work nonlinear precorrection has to be switched on." + ::= { exciterPrecorrectionEntry 13 } + + + excPrecNonlinThresholdShoulders OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "dB" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The target shoulder distance for ADE (0.0 ... 40.0)." + ::= { exciterPrecorrectionEntry 14 } + + + excPrecNonlinShoulderLeft OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "dB" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Displays the current measurement for the left handed shoulder distance." + ::= { exciterPrecorrectionEntry 15 } + + + excPrecNonlinShoulderRight OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "dB" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Displays the current measurement of the right handed shoulder." + ::= { exciterPrecorrectionEntry 16 } + + + excPrecNonlinInputLevel OBJECT-TYPE + SYNTAX INTEGER + { + tooHigh(1), + ok(2), + tooLow(3), + failure(4) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Shows the state of the feedback signal from the measurement point between output stage and antenna." + ::= { exciterPrecorrectionEntry 17 } + + + excPrecNonlinAutomatic OBJECT-TYPE + SYNTAX INTEGER + { + disabled(1), + active(2), + calculate(3), + measure(4) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Shows if the automatic precorrector works properly." + ::= { exciterPrecorrectionEntry 18 } + + + excPrecUserState OBJECT-TYPE + SYNTAX EqualizerCalibrationState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "status of the user precorrection settings" + ::= { exciterPrecorrectionEntry 100 } + + + excPrecFactoryState OBJECT-TYPE + SYNTAX EqualizerCalibrationState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "status of the factory precorrection settings" + ::= { exciterPrecorrectionEntry 101 } + + + excPrecRestoreCurrentSettings OBJECT-TYPE + SYNTAX INTEGER + { + stop(1), + start(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "restores current factory precorrection setting" + ::= { exciterPrecorrectionEntry 102 } + + + excPrecRestoreAllSettings OBJECT-TYPE + SYNTAX INTEGER + { + stop(1), + start(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "restores all factory precorrection settings" + ::= { exciterPrecorrectionEntry 103 } + + + configurationTable OBJECT-TYPE + SYNTAX SEQUENCE OF ConfigurationEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table for Type Configuration parameters." + ::= { detailedInfo 30 } + + + configurationEntry OBJECT-TYPE + SYNTAX ConfigurationEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry for the Type Configuration parameters." + INDEX { configTvStandardIdx } + ::= { configurationTable 1 } + + + ConfigurationEntry ::= + SEQUENCE { + configTvStandardIdx + TvStandard, + configTvStandardName + TvStandard, + configRxFrequency + Integer32, + configFrequency + Integer32, + configPower + FloatingPoint, + configInputSource + InputSource + } + + configTvStandardIdx OBJECT-TYPE + SYNTAX TvStandard + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The index for the TV standard." + ::= { configurationEntry 3 } + + + configTvStandardName OBJECT-TYPE + SYNTAX TvStandard + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The name of the TV standard as a text." + ::= { configurationEntry 5 } + + + configRxFrequency OBJECT-TYPE + SYNTAX Integer32 (160000000..910000000) + UNITS "Hz" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The input frequency for input 1." + ::= { configurationEntry 6 } + + + configFrequency OBJECT-TYPE + SYNTAX Integer32 (47000000..1500000000) + UNITS "Hz" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The output frequency for input 1." + ::= { configurationEntry 7 } + + + configPower OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "W" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The output power (0.0 ... 2500.0) for input 1." + ::= { configurationEntry 8 } + + + configInputSource OBJECT-TYPE + SYNTAX InputSource + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The source for input 1." + ::= { configurationEntry 9 } + + + timeSchedulerTable OBJECT-TYPE + SYNTAX SEQUENCE OF TimeSchedulerEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table for Time Scheduler parameters." + ::= { detailedInfo 31 } + + + timeSchedulerEntry OBJECT-TYPE + SYNTAX TimeSchedulerEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry in the table for the Time Scheduler parameters. + + A row in this table is created by setting the value of schedulerRowStatus to + 'createAndGo' or 'createAndWait'. + + A row in this table is deleted by setting the value of schedulerRowStatus to + 'destroy'." + INDEX { schedulerDateTimeIdx } + ::= { timeSchedulerTable 1 } + + + TimeSchedulerEntry ::= + SEQUENCE { + schedulerDateTimeIdx + DateAndTime, + schedulerRowStatus + RowStatus, + schedulerEvent + INTEGER, + schedulerDateTime + DateAndTime, + schedulerTvStandard + TvStandard + } + + schedulerDateTimeIdx OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The DateAndTime index. + + Note: Deci-seconds different from 0 and UTC values are ignored. + The index is implemented as a Fixed length string of 8 components. The last + component (Deci-seconds) is always 0. + Example: + The DateTime of 2008-9-15,17:45:30.0 + has the index: 7.216.9.15.17.45.30.0 + " + ::= { timeSchedulerEntry 3 } + + + schedulerRowStatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object is used to create and delete rows in the timeSchedulerTable." + ::= { timeSchedulerEntry 5 } + + + schedulerEvent OBJECT-TYPE + SYNTAX INTEGER + { + daily(1), + once(2) + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The event type." + ::= { timeSchedulerEntry 6 } + + + schedulerDateTime OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The start date and the time of a daily or one-time event." + ::= { timeSchedulerEntry 7 } + + + schedulerTvStandard OBJECT-TYPE + SYNTAX TvStandard + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The TV standard." + ::= { timeSchedulerEntry 8 } + + + configuration2Table OBJECT-TYPE + SYNTAX SEQUENCE OF Configuration2Entry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table for Type Configuration parameters of input 2." + ::= { detailedInfo 32 } + + + configuration2Entry OBJECT-TYPE + SYNTAX Configuration2Entry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry for the Type Configuration parameters of input 2." + AUGMENTS { configurationEntry } + ::= { configuration2Table 1 } + + + Configuration2Entry ::= + SEQUENCE { + config2TvStandardName + TvStandard, + config2RxFrequency + Integer32, + config2Frequency + Integer32, + config2Power + FloatingPoint, + config2InputSource + InputSource + } + + config2TvStandardName OBJECT-TYPE + SYNTAX TvStandard + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The name of the TV standard as a text." + ::= { configuration2Entry 5 } + + + config2RxFrequency OBJECT-TYPE + SYNTAX Integer32 (160000000..910000000) + UNITS "Hz" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The input frequency for input 2." + ::= { configuration2Entry 6 } + + + config2Frequency OBJECT-TYPE + SYNTAX Integer32 (47000000..1500000000) + UNITS "Hz" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The output frequency for input 2." + ::= { configuration2Entry 7 } + + + config2Power OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "W" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The output power (0.0 ... 2500.0) for input 2." + ::= { configuration2Entry 8 } + + + config2InputSource OBJECT-TYPE + SYNTAX InputSource + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The source for input 2." + ::= { configuration2Entry 9 } + + + productInfoTable OBJECT-TYPE + SYNTAX SEQUENCE OF ProductInfoEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The table for product typeplates." + ::= { detailedInfo 100 } + + + productInfoEntry OBJECT-TYPE + SYNTAX ProductInfoEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A row (an entry) for one typeplate." + INDEX { prodInfoModuleIdx, prodInfoDeviceIdx, prodInfoRackIdx, prodInfoAmpIdx } + ::= { productInfoTable 1 } + + + ProductInfoEntry ::= + SEQUENCE { + prodInfoModuleIdx + ProdInfoModuleNameTv, + prodInfoDeviceIdx + IndexAB, + prodInfoRackIdx + IndexRack, + prodInfoAmpIdx + IndexAmplifier, + prodInfoModuleName + ProdInfoModuleNameTv, + prodInfoSerialNumber + ReadableString, + prodInfoIdentNumberSW + ReadableString, + prodInfoVersionNumberSW + ReadableString, + prodInfoIdentNumberHW + ReadableString, + prodInfoVersionNumberHW + ReadableString, + productInfoProductDateHW + DateAndTime + } + + prodInfoModuleIdx OBJECT-TYPE + SYNTAX ProdInfoModuleNameTv + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The module index." + ::= { productInfoEntry 1 } + + + prodInfoDeviceIdx OBJECT-TYPE + SYNTAX IndexAB + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The dedicated device (A/B)." + ::= { productInfoEntry 2 } + + + prodInfoRackIdx OBJECT-TYPE + SYNTAX IndexRack + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The rack number (1..10)." + ::= { productInfoEntry 3 } + + + prodInfoAmpIdx OBJECT-TYPE + SYNTAX IndexAmplifier + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Amplifier Index" + ::= { productInfoEntry 4 } + + + prodInfoModuleName OBJECT-TYPE + SYNTAX ProdInfoModuleNameTv + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The name of the module as a text." + ::= { productInfoEntry 5 } + + + prodInfoSerialNumber OBJECT-TYPE + SYNTAX ReadableString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The serial number of the subdevice." + ::= { productInfoEntry 6 } + + + prodInfoIdentNumberSW OBJECT-TYPE + SYNTAX ReadableString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The Rohde&Schwarz identification number of the software, for example 2094.2090.02." + ::= { productInfoEntry 7 } + + + prodInfoVersionNumberSW OBJECT-TYPE + SYNTAX ReadableString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The Rohde&Schwarz revision number of the software, for example 1.2.1." + ::= { productInfoEntry 8 } + + + prodInfoIdentNumberHW OBJECT-TYPE + SYNTAX ReadableString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The Rohde&Schwarz identification number of the hardware, for example 2095.8007.02 (NetCCU)." + ::= { productInfoEntry 9 } + + + prodInfoVersionNumberHW OBJECT-TYPE + SYNTAX ReadableString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The Rohde&Schwarz revision number (product index) of the hardware, for example 03.03." + ::= { productInfoEntry 10 } + + + productInfoProductDateHW OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The Rohde&Schwarz production date of the hardware," + ::= { productInfoEntry 11 } + + + logbook OBJECT IDENTIFIER ::= { rsXx8000DvbTxObjs 4 } + + + netCCUNumberOfEntries OBJECT-TYPE + SYNTAX LogbookMaxEntryNumber + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of entries in logbook." + ::= { logbook 1 } + + + netCCULogbookClear OBJECT-TYPE + SYNTAX Trigger + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Clear the logbook. + idle(1) --> ready + clear(2) --> do clear now + + A GET will always return idle(1). A SET idle(1) will return NO_ERROR without doing anything." + ::= { logbook 2 } + + + netCCULogbookTable OBJECT-TYPE + SYNTAX SEQUENCE OF NetCCULogbookEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "NetCCU logbook table." + ::= { logbook 3 } + + + netCCULogbookEntry OBJECT-TYPE + SYNTAX NetCCULogbookEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This is a entry in the logbook." + INDEX { netCCULogbookEntryIdx } + ::= { netCCULogbookTable 1 } + + + NetCCULogbookEntry ::= + SEQUENCE { + netCCULogbookEntryIdx + LogbookMaxEntryNumber, + netCCULogbookEntryNbr + LogbookMaxEntryNumber, + netCCULogbookType + EventClass, + netCCULogbookSlope + LogbookEntrySlope, + netCCULogbookMessage + LogbookEntryMessagesNetCCU, + netCCULogbookDateTime + DateAndTime + } + + netCCULogbookEntryIdx OBJECT-TYPE + SYNTAX LogbookMaxEntryNumber + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This is an increasing number from 1 to maximum. It is used as an index column for SNMP." + ::= { netCCULogbookEntry 1 } + + + netCCULogbookEntryNbr OBJECT-TYPE + SYNTAX LogbookMaxEntryNumber + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This is the number of the logbook entry. It is an decreasing number from maximum down to 1." + ::= { netCCULogbookEntry 2 } + + + netCCULogbookType OBJECT-TYPE + SYNTAX EventClass + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Can either be Fault, Warning or State." + ::= { netCCULogbookEntry 3 } + + + netCCULogbookSlope OBJECT-TYPE + SYNTAX LogbookEntrySlope + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Either set (event raises) or reset (event disappears)" + ::= { netCCULogbookEntry 4 } + + + netCCULogbookMessage OBJECT-TYPE + SYNTAX LogbookEntryMessagesNetCCU + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "See RS-XX8000-COMMON-MIB - TextualConvention - LogbookEntryMessagesNetCCU for details." + ::= { netCCULogbookEntry 5 } + + + netCCULogbookDateTime OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "netCCULogbookDateTime" + ::= { netCCULogbookEntry 6 } + + + exciterANumberOfEntries OBJECT-TYPE + SYNTAX LogbookMaxEntryNumber + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of entries in logbook." + ::= { logbook 4 } + + + exciterALogbookClear OBJECT-TYPE + SYNTAX Trigger + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Clear the logbook. + idle(1) --> ready + clear(2) --> do clear now + + A GET will always return idle(1). A SET idle(1) will return NO_ERROR without doing anything." + ::= { logbook 5 } + + + exciterALogbookTable OBJECT-TYPE + SYNTAX SEQUENCE OF ExciterALogbookEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "ExciterA logbook table." + ::= { logbook 6 } + + + exciterALogbookEntry OBJECT-TYPE + SYNTAX ExciterALogbookEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This is a entry in the logbook." + INDEX { excALogbookEntryIdx } + ::= { exciterALogbookTable 1 } + + + ExciterALogbookEntry ::= + SEQUENCE { + excALogbookEntryIdx + LogbookMaxEntryNumber, + excALogbookEntryNbr + LogbookMaxEntryNumber, + excALogbookType + EventClass, + excALogbookSlope + LogbookEntrySlope, + excALogbookMessage + LogbookEntryMessagesExcTv, + excALogbookDateTime + DateAndTime + } + + excALogbookEntryIdx OBJECT-TYPE + SYNTAX LogbookMaxEntryNumber + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This is an increasing number from 1 to maximum. It is used as an index column for SNMP." + ::= { exciterALogbookEntry 1 } + + + excALogbookEntryNbr OBJECT-TYPE + SYNTAX LogbookMaxEntryNumber + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This is the number of the logbook entry. It is an decreasing number from maximum down to 1." + ::= { exciterALogbookEntry 2 } + + + excALogbookType OBJECT-TYPE + SYNTAX EventClass + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Can either be Fault, Warning or State." + ::= { exciterALogbookEntry 3 } + + + excALogbookSlope OBJECT-TYPE + SYNTAX LogbookEntrySlope + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Either set (event raises) or reset (event disappears)" + ::= { exciterALogbookEntry 4 } + + + excALogbookMessage OBJECT-TYPE + SYNTAX LogbookEntryMessagesExcTv + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "See RS-XX8000-COMMON-MIB - TextualConvention for details." + ::= { exciterALogbookEntry 5 } + + + excALogbookDateTime OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The time of the logbook entry." + ::= { exciterALogbookEntry 6 } + + + outputstageANumberOfEntries OBJECT-TYPE + SYNTAX LogbookMaxEntryNumber + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of entries in logbook." + ::= { logbook 7 } + + + outputstageALogbookClear OBJECT-TYPE + SYNTAX Trigger + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Clear the logbook. + idle(1) --> ready + clear(2) --> do clear now + + A GET will always return idle(1). A SET idle(1) will return NO_ERROR without doing anything." + ::= { logbook 8 } + + + outputstageALogbookTable OBJECT-TYPE + SYNTAX SEQUENCE OF OutputstageALogbookEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "OutputstageA logbook table." + ::= { logbook 9 } + + + outputstageALogbookEntry OBJECT-TYPE + SYNTAX OutputstageALogbookEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This is a entry in the logbook." + INDEX { ostALogbookEntryIdx } + ::= { outputstageALogbookTable 1 } + + + OutputstageALogbookEntry ::= + SEQUENCE { + ostALogbookEntryIdx + LogbookMaxEntryNumber, + ostALogbookEntryNbr + LogbookMaxEntryNumber, + ostALogbookType + EventClass, + ostALogbookSlope + LogbookEntrySlope, + ostALogbookMessage + LogbookEntryMessagesOST, + ostALogbookDateTime + DateAndTime + } + + ostALogbookEntryIdx OBJECT-TYPE + SYNTAX LogbookMaxEntryNumber + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This is an increasing number from 1 to maximum. It is used as an index column for SNMP." + ::= { outputstageALogbookEntry 1 } + + + ostALogbookEntryNbr OBJECT-TYPE + SYNTAX LogbookMaxEntryNumber + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This is the number of the logbook entry. It is an decreasing number from maximum down to 1." + ::= { outputstageALogbookEntry 2 } + + + ostALogbookType OBJECT-TYPE + SYNTAX EventClass + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Can either be Fault, Warning or State." + ::= { outputstageALogbookEntry 3 } + + + ostALogbookSlope OBJECT-TYPE + SYNTAX LogbookEntrySlope + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Either set (event raises) or reset (event disappears)" + ::= { outputstageALogbookEntry 4 } + + + ostALogbookMessage OBJECT-TYPE + SYNTAX LogbookEntryMessagesOST + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "See RS-XX8000-COMMON-MIB - TextualConvention for details." + ::= { outputstageALogbookEntry 5 } + + + ostALogbookDateTime OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The time of the logbook entry." + ::= { outputstageALogbookEntry 6 } + + + exciterBNumberOfEntries OBJECT-TYPE + SYNTAX LogbookMaxEntryNumber + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of entries in logbook." + ::= { logbook 10 } + + + exciterBLogbookClear OBJECT-TYPE + SYNTAX Trigger + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Clear the logbook. + idle(1) --> ready + clear(2) --> do clear now + + A GET will always return idle(1). A SET idle(1) will return NO_ERROR without doing anything." + ::= { logbook 11 } + + + exciterBLogbookTable OBJECT-TYPE + SYNTAX SEQUENCE OF ExciterBLogbookEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "ExciterB logbook table." + ::= { logbook 12 } + + + exciterBLogbookEntry OBJECT-TYPE + SYNTAX ExciterBLogbookEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This is a entry in the logbook." + INDEX { excBLogbookEntryIdx } + ::= { exciterBLogbookTable 1 } + + + ExciterBLogbookEntry ::= + SEQUENCE { + excBLogbookEntryIdx + LogbookMaxEntryNumber, + excBLogbookEntryNbr + LogbookMaxEntryNumber, + excBLogbookType + EventClass, + excBLogbookSlope + LogbookEntrySlope, + excBLogbookMessage + LogbookEntryMessagesExcTv, + excBLogbookDateTime + DateAndTime + } + + excBLogbookEntryIdx OBJECT-TYPE + SYNTAX LogbookMaxEntryNumber + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This is an increasing number from 1 to maximum. It is used as an index column for SNMP." + ::= { exciterBLogbookEntry 1 } + + + excBLogbookEntryNbr OBJECT-TYPE + SYNTAX LogbookMaxEntryNumber + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This is the number of the logbook entry. It is an decreasing number from maximum down to 1." + ::= { exciterBLogbookEntry 2 } + + + excBLogbookType OBJECT-TYPE + SYNTAX EventClass + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Can either be Fault, Warning or State." + ::= { exciterBLogbookEntry 3 } + + + excBLogbookSlope OBJECT-TYPE + SYNTAX LogbookEntrySlope + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Either set (event raises) or reset (event disappears)" + ::= { exciterBLogbookEntry 4 } + + + excBLogbookMessage OBJECT-TYPE + SYNTAX LogbookEntryMessagesExcTv + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "See RS-XX8000-COMMON-MIB - TextualConvention for details." + ::= { exciterBLogbookEntry 5 } + + + excBLogbookDateTime OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The time of the logbook entry." + ::= { exciterBLogbookEntry 6 } + + + outputstageBNumberOfEntries OBJECT-TYPE + SYNTAX LogbookMaxEntryNumber + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of entries in logbook." + ::= { logbook 13 } + + + outputstageBLogbookClear OBJECT-TYPE + SYNTAX Trigger + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Clear the logbook. + idle(1) --> ready + clear(2) --> do clear now + + A GET will always return idle(1). A SET idle(1) will return NO_ERROR without doing anything." + ::= { logbook 14 } + + + outputstageBLogbookTable OBJECT-TYPE + SYNTAX SEQUENCE OF OutputstageBLogbookEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "OutputstageB logbook table." + ::= { logbook 15 } + + + outputstageBLogbookEntry OBJECT-TYPE + SYNTAX OutputstageBLogbookEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This is a entry in the logbook." + INDEX { ostBLogbookEntryIdx } + ::= { outputstageBLogbookTable 1 } + + + OutputstageBLogbookEntry ::= + SEQUENCE { + ostBLogbookEntryIdx + LogbookMaxEntryNumber, + ostBLogbookEntryNbr + LogbookMaxEntryNumber, + ostBLogbookType + EventClass, + ostBLogbookSlope + LogbookEntrySlope, + ostBLogbookMessage + LogbookEntryMessagesOST, + ostBLogbookDateTime + DateAndTime + } + + ostBLogbookEntryIdx OBJECT-TYPE + SYNTAX LogbookMaxEntryNumber + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This is an increasing number from 1 to 128. It is used as an index column for SNMP." + ::= { outputstageBLogbookEntry 1 } + + + ostBLogbookEntryNbr OBJECT-TYPE + SYNTAX LogbookMaxEntryNumber + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This is the number of the logbook entry. It is an decreasing number from max 128 down to 1." + ::= { outputstageBLogbookEntry 2 } + + + ostBLogbookType OBJECT-TYPE + SYNTAX EventClass + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Can either be Fault, Warning or State." + ::= { outputstageBLogbookEntry 3 } + + + ostBLogbookSlope OBJECT-TYPE + SYNTAX LogbookEntrySlope + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Either set (event raises) or reset (event disappears)" + ::= { outputstageBLogbookEntry 4 } + + + ostBLogbookMessage OBJECT-TYPE + SYNTAX LogbookEntryMessagesOST + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "See RS-XX8000-COMMON-MIB - TextualConvention for details." + ::= { outputstageBLogbookEntry 5 } + + + ostBLogbookDateTime OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The time of the logbook entry." + ::= { outputstageBLogbookEntry 6 } + + + rfProbesTable OBJECT-TYPE + SYNTAX SEQUENCE OF RfProbesEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains all commands for the RF probes." + ::= { rsXx8000DvbTxObjs 5 } + + + rfProbesEntry OBJECT-TYPE + SYNTAX RfProbesEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry for a designated transmitter and device." + INDEX { rfProbesOstIdx } + ::= { rfProbesTable 1 } + + + RfProbesEntry ::= + SEQUENCE { + rfProbesNetCCURfProbe1 + FloatingPoint, + rfProbesNetCCURfProbe2 + FloatingPoint, + rfProbesAntFwdNominal + FloatingPoint, + rfProbesAntFwdWarningLimit + FloatingPoint, + rfProbesAntFwdFailLimit + FloatingPoint, + rfProbesAntFwdDelayTimeRfFail + Integer32, + rfProbesAntFwdSetOffset + Trigger, + rfProbesAntFwdSetGain + Trigger, + rfProbesAntReflWarningLimit + FloatingPoint, + rfProbesAntReflSetOffset + Trigger, + rfProbesAntReflSetGain + Trigger, + rfProbesDLFwdNominal + FloatingPoint, + rfProbesDLFwdWarningLimit + FloatingPoint, + rfProbesDLFwdFailLimit + FloatingPoint, + rfProbesDLFwdDelayTimeRfFail + Integer32, + rfProbesDLFwdSetOffset + Trigger, + rfProbesDLFwdSetGain + Trigger, + rfProbesDLReflWarningLimit + FloatingPoint, + rfProbesDLReflSetOffset + Trigger, + rfProbesDLReflSetGain + Trigger, + rfProbesOstIdx + IndexAB, + rfProbesOstFwdNominal + FloatingPoint, + rfProbesOstFwdWarningLimit + FloatingPoint, + rfProbesOstFwdFailLimit + FloatingPoint, + rfProbesOstFwdDelayTimeRfFail + Integer32, + rfProbesOstFwdSetOffset + Trigger, + rfProbesOstFwdSetGain + Trigger, + rfProbesOstReflWarningLimit + FloatingPoint, + rfProbesOstReflSetOffset + Trigger, + rfProbesOstReflSetGain + Trigger + } + + rfProbesNetCCURfProbe1 OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Volt" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current voltage on RF Probe 1." + ::= { rfProbesEntry 1 } + + + rfProbesNetCCURfProbe2 OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Volt" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current voltage on RF Probe 2." + ::= { rfProbesEntry 2 } + + + rfProbesAntFwdNominal OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Watt" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This sets the nominal value [W] of the transmitter (to antenna)." + ::= { rfProbesEntry 3 } + + + rfProbesAntFwdWarningLimit OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "dB" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This sets the warning limit for the transmitters RF control (to antenna)." + ::= { rfProbesEntry 4 } + + + rfProbesAntFwdFailLimit OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "dB" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This sets the fault limit for the transmitters RF control (to antenna)." + ::= { rfProbesEntry 5 } + + + rfProbesAntFwdDelayTimeRfFail OBJECT-TYPE + SYNTAX Integer32 (1..20) + UNITS "seconds" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This sets the delay time for the RF Fail control (to antenna)." + ::= { rfProbesEntry 6 } + + + rfProbesAntFwdSetOffset OBJECT-TYPE + SYNTAX Trigger + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This triggers Set Offset." + ::= { rfProbesEntry 7 } + + + rfProbesAntFwdSetGain OBJECT-TYPE + SYNTAX Trigger + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This triggers Set Gain." + ::= { rfProbesEntry 8 } + + + rfProbesAntReflWarningLimit OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "dB" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This sets the warning limit for the transmitters reflection control (to antenna)." + ::= { rfProbesEntry 9 } + + + rfProbesAntReflSetOffset OBJECT-TYPE + SYNTAX Trigger + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This triggers Set Offset." + ::= { rfProbesEntry 10 } + + + rfProbesAntReflSetGain OBJECT-TYPE + SYNTAX Trigger + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This triggers Set Gain." + ::= { rfProbesEntry 11 } + + + rfProbesDLFwdNominal OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Watt" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This sets the nominal value [W] of the transmitter (to dummyload)." + ::= { rfProbesEntry 12 } + + + rfProbesDLFwdWarningLimit OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "dB" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This sets the warning limit for the transmitters RF control (to dummyload)." + ::= { rfProbesEntry 13 } + + + rfProbesDLFwdFailLimit OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "dB" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This sets the fault limit for the transmitters RF control (to dummyload)." + ::= { rfProbesEntry 14 } + + + rfProbesDLFwdDelayTimeRfFail OBJECT-TYPE + SYNTAX Integer32 (1..20) + UNITS "seconds" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This sets the delay time for the RF Fail control (to dummyload)." + ::= { rfProbesEntry 15 } + + + rfProbesDLFwdSetOffset OBJECT-TYPE + SYNTAX Trigger + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This triggers Set Offset." + ::= { rfProbesEntry 16 } + + + rfProbesDLFwdSetGain OBJECT-TYPE + SYNTAX Trigger + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This triggers Set Gain." + ::= { rfProbesEntry 17 } + + + rfProbesDLReflWarningLimit OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "dB" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This sets the warning limit for the transmitters reflection control (to dummyload)." + ::= { rfProbesEntry 18 } + + + rfProbesDLReflSetOffset OBJECT-TYPE + SYNTAX Trigger + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This triggers Set Offset." + ::= { rfProbesEntry 19 } + + + rfProbesDLReflSetGain OBJECT-TYPE + SYNTAX Trigger + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This triggers Set Gain." + ::= { rfProbesEntry 20 } + + + rfProbesOstIdx OBJECT-TYPE + SYNTAX IndexAB + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The dedicated outputstage (A/B)." + ::= { rfProbesEntry 21 } + + + rfProbesOstFwdNominal OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Watt" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This sets the nominal value [W] of the outputstage." + ::= { rfProbesEntry 22 } + + + rfProbesOstFwdWarningLimit OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "dB" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This sets the warning limit for the outputstage RF control." + ::= { rfProbesEntry 23 } + + + rfProbesOstFwdFailLimit OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "dB" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This sets the fault limit for the outputstage RF control." + ::= { rfProbesEntry 24 } + + + rfProbesOstFwdDelayTimeRfFail OBJECT-TYPE + SYNTAX Integer32 (1..20) + UNITS "seconds" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This sets the delay time for the outputstage RF Fail control." + ::= { rfProbesEntry 25 } + + + rfProbesOstFwdSetOffset OBJECT-TYPE + SYNTAX Trigger + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This triggers Set Offset." + ::= { rfProbesEntry 26 } + + + rfProbesOstFwdSetGain OBJECT-TYPE + SYNTAX Trigger + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This triggers Set Gain." + ::= { rfProbesEntry 27 } + + + rfProbesOstReflWarningLimit OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "dB" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This sets the warning limit for the outputstage reflection control." + ::= { rfProbesEntry 28 } + + + rfProbesOstReflSetOffset OBJECT-TYPE + SYNTAX Trigger + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This triggers Set Offset." + ::= { rfProbesEntry 29 } + + + rfProbesOstReflSetGain OBJECT-TYPE + SYNTAX Trigger + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This triggers Set Gain." + ::= { rfProbesEntry 30 } + + + rackTable OBJECT-TYPE + SYNTAX SEQUENCE OF RackEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains important commands for the racks." + ::= { rsXx8000DvbTxObjs 6 } + + + rackEntry OBJECT-TYPE + SYNTAX RackEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry for a designated rack or rack's rf probe." + INDEX { ostDeviceIdx, rackIdx, rackRfProbeIdx } + ::= { rackTable 1 } + + + RackEntry ::= + SEQUENCE { + ostDeviceIdx + IndexAB, + rackIdx + IndexRack, + rackRfProbeIdx + INTEGER, + amplifiersPerRack + Integer32, + rackRfEventSignalling + TruthValue, + rackReferenceVoltage + FloatingPoint, + amplifiersPowerSupply + FloatingPoint, + rackGeneralPurposeInput + INTEGER, + rackOnOff + SwitchOnOff, + rfProbePresent + TruthValue, + rfProbeConfigurationLabel + ReadableString, + rfProbeConfigurationNominalValue + Integer32, + rfProbeThresholdRfFailLimit + FloatingPoint, + rfProbeThresholdTimeoutRfFailCtr + Integer32, + rfProbeThresholdWarningLimit + FloatingPoint, + rfProbeCalibrationGain + FloatingPoint, + rfProbeCalibrationOffset + FloatingPoint, + rfProbeCalibrationSetGain + Trigger, + rfProbeCalibrationSetOffset + Trigger, + rfProbeMeasuredValue + FloatingPoint + } + + ostDeviceIdx OBJECT-TYPE + SYNTAX IndexAB + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The index to address outputstageA and outputstageB." + ::= { rackEntry 2 } + + + rackIdx OBJECT-TYPE + SYNTAX IndexRack + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The index to address the racks." + ::= { rackEntry 3 } + + + rackRfProbeIdx OBJECT-TYPE + SYNTAX INTEGER + { + forward(1), + reflected(2) + } + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The index to address forward and reflected RF probes. + For not RF probe parameters this index is always 1." + ::= { rackEntry 4 } + + + amplifiersPerRack OBJECT-TYPE + SYNTAX Integer32 (1..10) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of amplifiers of a rack." + ::= { rackEntry 6 } + + + rackRfEventSignalling OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This configures whether to signal rf events or not." + ::= { rackEntry 7 } + + + rackReferenceVoltage OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "percent" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This parameter controls the reference voltage (31.0 ... 100.0)." + ::= { rackEntry 8 } + + + amplifiersPowerSupply OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "percent" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This parameter controls the power supplies of the amplifier + within the rack (31.0 ... 100.0)." + ::= { rackEntry 9 } + + + rackGeneralPurposeInput OBJECT-TYPE + SYNTAX INTEGER + { + unused(1), + doorOpen(2), + extCoolingWarning(3), + extCoolingFault(4) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Setting of the general purpose input behaviour." + ::= { rackEntry 10 } + + + rackOnOff OBJECT-TYPE + SYNTAX SwitchOnOff + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This switches the rack on/off." + ::= { rackEntry 20 } + + + rfProbePresent OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "If the RF probe of this rack is present." + ::= { rackEntry 50 } + + + rfProbeConfigurationLabel OBJECT-TYPE + SYNTAX ReadableString (SIZE (0..12)) + MAX-ACCESS read-write + STATUS obsolete + DESCRIPTION + "Name for the measured signal on RF Probe." + ::= { rackEntry 51 } + + + rfProbeConfigurationNominalValue OBJECT-TYPE + SYNTAX Integer32 (0..100000) + UNITS "W" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The nominal value of the measured signal." + ::= { rackEntry 52 } + + + rfProbeThresholdRfFailLimit OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "dB" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Fault limit for the RF control (-20.0 ... 0.0)." + ::= { rackEntry 55 } + + + rfProbeThresholdTimeoutRfFailCtr OBJECT-TYPE + SYNTAX Integer32 (1..20) + UNITS "s" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Timeout for RF Fail Control." + ::= { rackEntry 56 } + + + rfProbeThresholdWarningLimit OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "dB" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Warning limit for the RF control (-20.0 ... 0.0). + + For reflected probes: + Warning limit for the reflection control. This limit is added to the + fault limit to generate the real warning limit; e.g. the fault limit + is -17.0dB and the warning limit is -3.0dB, so the warning is active + on a reflected power higher than -20.0 dB." + ::= { rackEntry 57 } + + + rfProbeCalibrationGain OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "V" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Measured value of gain calibration." + ::= { rackEntry 60 } + + + rfProbeCalibrationOffset OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "V" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Measured value of offset calibration." + ::= { rackEntry 61 } + + + rfProbeCalibrationSetGain OBJECT-TYPE + SYNTAX Trigger + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Sets the gain calibration." + ::= { rackEntry 62 } + + + rfProbeCalibrationSetOffset OBJECT-TYPE + SYNTAX Trigger + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Sets the offset calibration." + ::= { rackEntry 63 } + + + rfProbeMeasuredValue OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "W" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Measured forward/reflected power of antenna signal." + ::= { rackEntry 65 } + + + sx801AmplifierTable OBJECT-TYPE + SYNTAX SEQUENCE OF Sx801AmplifierEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Amplifier status values for SX801 amplifiers." + ::= { rsXx8000DvbTxObjs 7 } + + + sx801AmplifierEntry OBJECT-TYPE + SYNTAX Sx801AmplifierEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A row (an entry) for one amplifier." + INDEX { sx801AmpIdx } + ::= { sx801AmplifierTable 1 } + + + Sx801AmplifierEntry ::= + SEQUENCE { + sx801AmpIdx + IndexAmplifier, + sx801AmpRfOut + Sx801AmplifierState, + sx801AmpRfIn + Sx801AmplifierState, + sx801AmpReflection + INTEGER, + sx801AmpOn + INTEGER, + sx801AmpAC + Sx801AmplifierState, + sx801AmpCommunication + INTEGER, + sx801AmpTransistor + Sx801AmplifierState, + sx801AmpDriver + Sx801AmplifierState, + sx801AmpTemperature + Sx801AmplifierState, + sx801AmpBlower + Sx801AmplifierState, + sx801AmpRegulation + Sx801AmplifierState, + sx801AmpUpdate + TruthValue, + sx801Supply1Temperature + Sx801AmplifierState, + sx801Supply2Temperature + Sx801AmplifierState, + sx801SupplyRTemperature + Sx801AmplifierState, + sx801Supply1DC + Sx801AmplifierState, + sx801Supply2DC + Sx801AmplifierState, + sx801SupplyRDC + Sx801AmplifierState, + sx801AmpValueI1 + FloatingPoint, + sx801AmpValueI2 + FloatingPoint, + sx801AmpValueI3 + FloatingPoint, + sx801AmpValueI4 + FloatingPoint, + sx801AmpValueIPre + FloatingPoint, + sx801AmpValueIDrv1 + FloatingPoint, + sx801AmpValueIDrv2 + FloatingPoint, + sx801AmpValuePowerOut + FloatingPoint, + sx801AmpValueReflection + FloatingPoint, + sx801AmpValueVRef + FloatingPoint, + sx801AmpValueVReg + FloatingPoint, + sx801AmpValueTemperature + FloatingPoint, + sx801AmpValueMonAtt + FloatingPoint, + sx801AmpValueVAux1 + FloatingPoint, + sx801AmpValueVAux2 + FloatingPoint, + sx801Supply1ValuePwr + FloatingPoint, + sx801Supply2ValuePwr + FloatingPoint, + sx801Supply1ValueDc + FloatingPoint, + sx801Supply2ValueDc + FloatingPoint + } + + sx801AmpIdx OBJECT-TYPE + SYNTAX IndexAmplifier + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The amplifier index." + ::= { sx801AmplifierEntry 1 } + + + sx801AmpRfOut OBJECT-TYPE + SYNTAX Sx801AmplifierState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Shows if the amplifier generates an RF or not. + off(1): The amplifier output is switched off + e.g. because the amplifier gets no input signal or the transmitter has been switched off + warning(2): There is an RF but its level is less than the RF warning limit. + ok(3): The RF level is greater than the RF warning limit." + ::= { sx801AmplifierEntry 2 } + + + sx801AmpRfIn OBJECT-TYPE + SYNTAX Sx801AmplifierState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Displays the state of the amplifier input. + off(1): no input signal detected + warning(2): the level of the input signal is too low or too high. + ok(3): input signal is OK." + ::= { sx801AmplifierEntry 3 } + + + sx801AmpReflection OBJECT-TYPE + SYNTAX INTEGER + { + off(1), + warning(2), + unknown(3), + fault(4) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " A reflection on RF output of this Amplifier module has been detected. + This leads to a reduction of output power of the amplifier. + + " + ::= { sx801AmplifierEntry 4 } + + + sx801AmpOn OBJECT-TYPE + SYNTAX INTEGER + { + off(1), + on(3), + unknown(4) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Shows if the amplifier has been switched on by the control unit." + ::= { sx801AmplifierEntry 5 } + + + sx801AmpAC OBJECT-TYPE + SYNTAX Sx801AmplifierState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Shows the state of primary voltage of the power supply." + ::= { sx801AmplifierEntry 6 } + + + sx801AmpCommunication OBJECT-TYPE + SYNTAX INTEGER + { + off(1), + unknown(2), + ok(3), + fault(4) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Displays if the CAN communication between amplifier and Sx801 is working or not." + ::= { sx801AmplifierEntry 7 } + + + sx801AmpTransistor OBJECT-TYPE + SYNTAX Sx801AmplifierState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A transistor fail is displayed here. + For further information please see the amplifiers service menue." + ::= { sx801AmplifierEntry 8 } + + + sx801AmpDriver OBJECT-TYPE + SYNTAX Sx801AmplifierState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Shows a failure if one of the internal driver transistors does not work properly. + For further information please see the amplifiers service menue." + ::= { sx801AmplifierEntry 9 } + + + sx801AmpTemperature OBJECT-TYPE + SYNTAX Sx801AmplifierState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Shows a fault if the temperature of amplifier module is too high." + ::= { sx801AmplifierEntry 10 } + + + sx801AmpBlower OBJECT-TYPE + SYNTAX Sx801AmplifierState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Displays the state of the internal blowers." + ::= { sx801AmplifierEntry 11 } + + + sx801AmpRegulation OBJECT-TYPE + SYNTAX Sx801AmplifierState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Shows a fault if the amplifier is not able to control its output power." + ::= { sx801AmplifierEntry 12 } + + + sx801AmpUpdate OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Firmware update is in progress. + This will be started automatically during a software update procedure of the transmitter." + ::= { sx801AmplifierEntry 13 } + + + sx801Supply1Temperature OBJECT-TYPE + SYNTAX Sx801AmplifierState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Shows a fault if the temperature of power supply one is too high." + ::= { sx801AmplifierEntry 14 } + + + sx801Supply2Temperature OBJECT-TYPE + SYNTAX Sx801AmplifierState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Shows a fault if the temperature of power supply two is too high." + ::= { sx801AmplifierEntry 15 } + + + sx801SupplyRTemperature OBJECT-TYPE + SYNTAX Sx801AmplifierState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Shows a fault if the temperature of the reserve power supply is too high." + ::= { sx801AmplifierEntry 16 } + + + sx801Supply1DC OBJECT-TYPE + SYNTAX Sx801AmplifierState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Shows a fault if the output voltage of power supply one is not ok." + ::= { sx801AmplifierEntry 17 } + + + sx801Supply2DC OBJECT-TYPE + SYNTAX Sx801AmplifierState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Shows a fault if the output voltage of power supply two is not ok." + ::= { sx801AmplifierEntry 18 } + + + sx801SupplyRDC OBJECT-TYPE + SYNTAX Sx801AmplifierState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Shows a fault if the output voltage of the reserve power supply is not ok." + ::= { sx801AmplifierEntry 19 } + + + sx801AmpValueI1 OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Ampere" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The internal current from transistor pair 1." + ::= { sx801AmplifierEntry 50 } + + + sx801AmpValueI2 OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Ampere" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The internal current from transistor pair 2." + ::= { sx801AmplifierEntry 51 } + + + sx801AmpValueI3 OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Ampere" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The internal current from transistor pair 3." + ::= { sx801AmplifierEntry 52 } + + + sx801AmpValueI4 OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Ampere" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The internal current from transistor pair 4." + ::= { sx801AmplifierEntry 53 } + + + sx801AmpValueIPre OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Ampere" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The internal current from preamplifier." + ::= { sx801AmplifierEntry 54 } + + + sx801AmpValueIDrv1 OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Ampere" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The internal current from driver transistor pair 1." + ::= { sx801AmplifierEntry 55 } + + + sx801AmpValueIDrv2 OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Ampere" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The internal current from driver transistor pair 2." + ::= { sx801AmplifierEntry 56 } + + + sx801AmpValuePowerOut OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Watt" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The base value in Volt to calculate the output power + of this amplifier module." + ::= { sx801AmplifierEntry 57 } + + + sx801AmpValueReflection OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Watt" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The base value in Volt for detection of reflections." + ::= { sx801AmplifierEntry 58 } + + + sx801AmpValueVRef OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Volt" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The internal reference voltage to set the output power." + ::= { sx801AmplifierEntry 59 } + + + sx801AmpValueVReg OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Volt" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The internal value for output power regulation." + ::= { sx801AmplifierEntry 60 } + + + sx801AmpValueTemperature OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "degree Celsius" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The internal temperature of Amplifier. + In case of L-band amplifier, the shown temperature is valid only, + if the amplifier is switched on." + ::= { sx801AmplifierEntry 61 } + + + sx801AmpValueMonAtt OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "dB" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The attenuation of monitoring output on the front of the + amplifier module (Amp RF Mon)." + ::= { sx801AmplifierEntry 62 } + + + sx801AmpValueVAux1 OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Volt" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The voltage power detector 1." + ::= { sx801AmplifierEntry 63 } + + + sx801AmpValueVAux2 OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Volt" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The voltage power detector 2." + ::= { sx801AmplifierEntry 64 } + + + sx801Supply1ValuePwr OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Volt" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The power supply one control voltage." + ::= { sx801AmplifierEntry 65 } + + + sx801Supply2ValuePwr OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Volt" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The power supply two control voltage." + ::= { sx801AmplifierEntry 66 } + + + sx801Supply1ValueDc OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Volt" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The internal supply voltage of transistor path two. + In systems with two power supplies this value is equal + to the output voltage of supply one." + ::= { sx801AmplifierEntry 67 } + + + sx801Supply2ValueDc OBJECT-TYPE + SYNTAX FloatingPoint + UNITS "Volt" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The internal supply voltage of transistor path two. + In systems with two power supplies this value is equal + to the output voltage of supply two." + ::= { sx801AmplifierEntry 68 } + + +-- ***************************************************************************** +-- ** event definitions +-- ***************************************************************************** + rsXx8000DvbTxEvents OBJECT IDENTIFIER ::= { rsXx8000DvbTx 3 } + + +-- ***************************************************************************** +-- ** events transmitter +-- ***************************************************************************** + eventTx OBJECT IDENTIFIER ::= { rsXx8000DvbTxEvents 2 } + + + eventsTxV2 OBJECT-IDENTITY + STATUS current + DESCRIPTION + "Compatibility to SMIv1." + ::= { eventTx 0 } + + + txSummaryFault NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent } + STATUS current + DESCRIPTION + "Transmitter Summary Fault" + ::= { eventsTxV2 1 } + + + txSummaryWarning NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent } + STATUS current + DESCRIPTION + "Transmitter Summary Warning" + ::= { eventsTxV2 2 } + + + txLocal NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent } + STATUS current + DESCRIPTION + "Transmitter Local/Remote" + ::= { eventsTxV2 3 } + + + txRfOn NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent } + STATUS current + DESCRIPTION + "Transmitter RF On/Off" + ::= { eventsTxV2 4 } + + + txRfOk NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent } + STATUS current + DESCRIPTION + "Transmitter RF Ok / Not OK" + ::= { eventsTxV2 5 } + + + txParamSetSubDeviceDiffers NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent } + STATUS obsolete + DESCRIPTION + "Parameterset of subdevice is different. + The currently loaded parameterset is inconsistent because + a subdevice (e.g. an exciter) has a different configuration than expected. + To correct this, save settings to the current or save a complete new." + ::= { eventsTxV2 6 } + + + txParamSetValuesChanged NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent } + STATUS current + DESCRIPTION + "Value Of Current Parameterset Changed. + The currently loaded parameterset is inconsistent because + there were changes happening since the load/save of it. + To correct this, save settings to the current or save a complete new." + ::= { eventsTxV2 7 } + + + txRfLoopProgram NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent } + STATUS current + DESCRIPTION + "NetCCU Loop Program" + ::= { eventsTxV2 8 } + + + txRfLoopReserve NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent } + STATUS current + DESCRIPTION + "NetCCU Loop Reserve" + ::= { eventsTxV2 9 } + + + txRfWarning NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent } + STATUS current + DESCRIPTION + "NetCCU RF Warning" + ::= { eventsTxV2 10 } + + + txReflectionWarning NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent } + STATUS current + DESCRIPTION + "NetCCU Reflection Warning" + ::= { eventsTxV2 11 } + + + txNetCCUFanFault NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent } + STATUS current + DESCRIPTION + "NetCCU Fan Fault. + This is valid, if Fan Control is switched on (see menu NetCCU Setup - Common)." + ::= { eventsTxV2 12 } + + + txNetCCUPowerSupply NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent } + STATUS current + DESCRIPTION + "NetCCU Power Supply" + ::= { eventsTxV2 13 } + + + txRfFail NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent } + STATUS current + DESCRIPTION + "NetCCU RF Fail" + ::= { eventsTxV2 14 } + + + txReflectionFault NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent } + STATUS current + DESCRIPTION + "NetCCU Reflection Fault" + ::= { eventsTxV2 15 } + + + txNetCCUBoardTemperatureFault NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent } + STATUS deprecated + DESCRIPTION + "NetCCU Board Temperature Fault + + deprecated: this information is now handled as a warning + (txNetCCUBoardTemperatureWarning)" + ::= { eventsTxV2 16 } + + + txNetCCUNoConnectionToExcA NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent } + STATUS current + DESCRIPTION + "NetCCU Connection To ExciterA Faulty" + ::= { eventsTxV2 17 } + + + txNetCCUNoConnectionToOstA NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent } + STATUS current + DESCRIPTION + "NetCCU Connection To OutputstageA Faulty" + ::= { eventsTxV2 18 } + + + txNetCCUNoConnectionToExcB NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent } + STATUS current + DESCRIPTION + "NetCCU Connection To ExciterB Faulty" + ::= { eventsTxV2 19 } + + + txNetCCUNoConnectionToOstB NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent } + STATUS current + DESCRIPTION + "NetCCU Connection To OutputstageB Faulty" + ::= { eventsTxV2 20 } + + + txAutomaticExcReady NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent } + STATUS current + DESCRIPTION + "Exciter Automatic Ready." + ::= { eventsTxV2 21 } + + + txAutomaticExcChanged NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent } + STATUS current + DESCRIPTION + "Exciter Automatic Changed." + ::= { eventsTxV2 22 } + + + txAutomaticExcFault NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent } + STATUS current + DESCRIPTION + "Exciter Automatic Fault." + ::= { eventsTxV2 23 } + + + txAutomaticOstReady NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent } + STATUS current + DESCRIPTION + "Outputstage Automatic Ready. + + This paramter is only available for systems with an automatic output switch." + ::= { eventsTxV2 24 } + + + txAutomaticOstChanged NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent } + STATUS current + DESCRIPTION + "Outputstage Automatic Changed. + + This paramter is only available for systems with an automatic output switch." + ::= { eventsTxV2 25 } + + + txAutomaticOstFault NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent } + STATUS current + DESCRIPTION + "Outputstage Automatic Fault. + + This paramter is only available for systems with an automatic output switch." + ::= { eventsTxV2 26 } + + + txNetCCUBoardTemperatureWarning NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent } + STATUS current + DESCRIPTION + "NetCCU Board Temperature Warning" + ::= { eventsTxV2 27 } + + + txInternalPowerSupplyWarning NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent } + STATUS current + DESCRIPTION + "NetCCU internal Power Supply warning" + ::= { eventsTxV2 30 } + + + txExternalPowerSupplyWarning NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent } + STATUS current + DESCRIPTION + "NetCCU external (additional) Power Supply warning" + ::= { eventsTxV2 31 } + + + txModeSwitchOverStarted NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent } + STATUS current + DESCRIPTION + "Switch over of TX mode started." + ::= { eventsTxV2 35 } + + + txModeSwitchOverEnded NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent } + STATUS current + DESCRIPTION + "Switch over of TX mode ended." + ::= { eventsTxV2 36 } + + + txModeInconsistent NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent } + STATUS current + DESCRIPTION + "An inconsistency in configuration of TX mode was detected. + The CCU and exiter configurations are incompatible." + ::= { eventsTxV2 37 } + + + txModeSwitchOverFailed NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent } + STATUS current + DESCRIPTION + "Switch over of TX mode failed. + Please check whether the configurations of CCU and exciter are correct." + ::= { eventsTxV2 38 } + + + txExcSummaryFault NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB } + STATUS current + DESCRIPTION + "Exciter Summary Fault" + ::= { eventsTxV2 100 } + + + txExcSummaryWarning NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB } + STATUS current + DESCRIPTION + "Exciter Summary Warning" + ::= { eventsTxV2 101 } + + + txExcLocal NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB } + STATUS current + DESCRIPTION + "Exciter Local/Remote" + ::= { eventsTxV2 102 } + + + txExcRfOk NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB } + STATUS current + DESCRIPTION + "Exciter RF Ok" + ::= { eventsTxV2 104 } + + + txExcInputNoConnectHP1 NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB } + STATUS current + DESCRIPTION + "Exciter Input HP1 has no connected input signal" + ::= { eventsTxV2 105 } + + + txExcInputNoConnectLP1 NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB } + STATUS current + DESCRIPTION + "Exciter Input LP1 has no connected input signal" + ::= { eventsTxV2 106 } + + + txExcInputNoConnectHP2 NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB } + STATUS current + DESCRIPTION + "Exciter Input HP2 has no connected input signal" + ::= { eventsTxV2 107 } + + + txExcInputNoConnectLP2 NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB } + STATUS current + DESCRIPTION + "Exciter Input LP2 has no connected input signal" + ::= { eventsTxV2 108 } + + + txExcInputActiveHP1 NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB } + STATUS current + DESCRIPTION + "Exciter Input HP1 is active" + ::= { eventsTxV2 109 } + + + txExcInputActiveLP1 NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB } + STATUS current + DESCRIPTION + "Exciter Input LP1 is active" + ::= { eventsTxV2 110 } + + + txExcInputActiveHP2 NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB } + STATUS current + DESCRIPTION + "Exciter Input HP2 is active" + ::= { eventsTxV2 111 } + + + txExcInputActiveLP2 NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB } + STATUS current + DESCRIPTION + "Exciter Input LP2 is active" + ::= { eventsTxV2 112 } + + + txExcOn NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB } + STATUS current + DESCRIPTION + "Exciter On" + ::= { eventsTxV2 113 } + + + txExcRfOn NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB } + STATUS current + DESCRIPTION + "Exciter RF On" + ::= { eventsTxV2 114 } + + + txExcNoInput NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB } + STATUS current + DESCRIPTION + "Exciter has no valid input signal." + ::= { eventsTxV2 115 } + + + txExcRfLoop NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB } + STATUS current + DESCRIPTION + "Exciter RF loop" + ::= { eventsTxV2 116 } + + + txExcRfFail NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB } + STATUS current + DESCRIPTION + "Exciter RF Fail" + ::= { eventsTxV2 117 } + + + txExcSelfTest NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB } + STATUS current + DESCRIPTION + "Exciter hardware self test" + ::= { eventsTxV2 118 } + + + txExcOutputOpen NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB } + STATUS current + DESCRIPTION + "Exciter output open" + ::= { eventsTxV2 119 } + + + txExcBoardTemperatureWarning NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB } + STATUS current + DESCRIPTION + "Exciter Board Temperature" + ::= { eventsTxV2 120 } + + + txExcFanWarning NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB } + STATUS current + DESCRIPTION + "Exciter has one faulty fan" + ::= { eventsTxV2 121 } + + + txExcFanFault NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB } + STATUS current + DESCRIPTION + "Both exciter fans are faulty." + ::= { eventsTxV2 122 } + + + txExcFifoWarning NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB } + STATUS current + DESCRIPTION + "Exciter Fifo" + ::= { eventsTxV2 123 } + + + txExcTestSignal NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB } + STATUS current + DESCRIPTION + "Exciter Testsignal Active" + ::= { eventsTxV2 124 } + + + txExcSFNDelay NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB } + STATUS current + DESCRIPTION + "Exciter SFN Delay Fault" + ::= { eventsTxV2 125 } + + + txExcWrongDatarate NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB } + STATUS current + DESCRIPTION + "Exciter Wrong Datarate" + ::= { eventsTxV2 126 } + + + txExcMute NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB } + STATUS current + DESCRIPTION + "Exciter Mute" + ::= { eventsTxV2 127 } + + + txExcPPSFail NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB } + STATUS current + DESCRIPTION + "Exciter PPS Fail" + ::= { eventsTxV2 128 } + + + txExcReferenceFail NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB } + STATUS current + DESCRIPTION + "Exciter Reference Fail" + ::= { eventsTxV2 129 } + + + txExcMIPFail NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB } + STATUS current + DESCRIPTION + "Exciter MIP Fail" + ::= { eventsTxV2 130 } + + + txExcInputAutomaticSwitchReady NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB } + STATUS current + DESCRIPTION + "Input automatic is ready." + ::= { eventsTxV2 131 } + + + txExcInputAutomaticChangedOver NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB } + STATUS current + DESCRIPTION + "Input automatic changed over." + ::= { eventsTxV2 132 } + + + txExcInputReseveMissing NOTIFICATION-TYPE + STATUS current + DESCRIPTION + "Missing input, or automatic switching enabled with only one input present. + Disable automatic switching or press reset fault to remove this warning. + Monitoring of a second input will start automatically if two input signals have been detected. + + This event will be generated only if cmdExcExpectInputReserve is set to on(1)." + ::= { eventsTxV2 133 } + + + txOstSummaryFault NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB } + STATUS current + DESCRIPTION + "Outputstage Summary Fault" + ::= { eventsTxV2 200 } + + + txOstSummaryWarning NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB } + STATUS current + DESCRIPTION + "Outputstage Summary Warning" + ::= { eventsTxV2 201 } + + + txOstRfOn NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB } + STATUS current + DESCRIPTION + "Outputstage RF On" + ::= { eventsTxV2 202 } + + + txOstRfOk NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB } + STATUS current + DESCRIPTION + "Outputstage RF Ok" + ::= { eventsTxV2 203 } + + + txOstNoInput NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB } + STATUS current + DESCRIPTION + "Outputstage no input signal" + ::= { eventsTxV2 204 } + + + txOstRfWarning NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB } + STATUS current + DESCRIPTION + "Outputstage RF Warning" + ::= { eventsTxV2 205 } + + + txOstReflectionWarning NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB } + STATUS current + DESCRIPTION + "Outputstage Reflection Warning" + ::= { eventsTxV2 206 } + + + txOstRackWarning NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB } + STATUS current + DESCRIPTION + "Outputstage Rack Warning. At least one rack has an error pending." + ::= { eventsTxV2 207 } + + + txOstCoolingWarning NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB } + STATUS current + DESCRIPTION + "Outputstage Cooling Warning" + ::= { eventsTxV2 208 } + + + txOstRfFail NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB } + STATUS current + DESCRIPTION + "Outputstage RF Fail" + ::= { eventsTxV2 209 } + + + txOstReflectionFault NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB } + STATUS current + DESCRIPTION + "Outputstage Reflection Fault" + ::= { eventsTxV2 210 } + + + txOstACFault NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB } + STATUS current + DESCRIPTION + "Outputstage AC Fault" + ::= { eventsTxV2 211 } + + + txOstCoolingFault NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB } + STATUS current + DESCRIPTION + "Outputstage Cooling Fault" + ::= { eventsTxV2 212 } + + + txOstCommFault NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB } + STATUS current + DESCRIPTION + "Outputstage Communication Fault" + ::= { eventsTxV2 213 } + + + txRackSumFault NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack + } + STATUS current + DESCRIPTION + "Summary Fault at a designated rack. + This event automatically leads to txOstRackWarning." + ::= { eventsTxV2 300 } + + + txRackSumWarning NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack + } + STATUS current + DESCRIPTION + "Summary Warning at a designated rack." + ::= { eventsTxV2 301 } + + + txRackOn NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack + } + STATUS current + DESCRIPTION + "The designated racks operation mode is on." + ::= { eventsTxV2 302 } + + + txRackGpiWarning NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack + } + STATUS current + DESCRIPTION + "A warning on the general purpose input occurred. + This depends on the current configuration of the GPI. (See:Rack Setup/Rack Controller)" + ::= { eventsTxV2 303 } + + + txRackFan1Fault NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack + } + STATUS current + DESCRIPTION + "The designated rack signals a fault of fan 1." + ::= { eventsTxV2 304 } + + + txRackFan2Fault NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack + } + STATUS current + DESCRIPTION + "The designated rack signals a fault of fan 2." + ::= { eventsTxV2 305 } + + + txRackCoolingSumWarning NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack + } + STATUS current + DESCRIPTION + "The designated rack signals a summary cooling warning." + ::= { eventsTxV2 306 } + + + txRackAmplifierSumFault NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack + } + STATUS current + DESCRIPTION + "The designated rack signals at least one faulty amplifier." + ::= { eventsTxV2 307 } + + + txRackNoLink NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack + } + STATUS current + DESCRIPTION + "No communication to the designated rack." + ::= { eventsTxV2 308 } + + + txRackGpiFault NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack + } + STATUS current + DESCRIPTION + "A fault on the general purpose input occurred. + This depends on the current configuration of the GPI. (See:Rack Setup/Rack Controller)" + ::= { eventsTxV2 309 } + + + txRackTemperatureFault NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack + } + STATUS current + DESCRIPTION + "The designated rack signals a temperature fault - temperature too high." + ::= { eventsTxV2 310 } + + + txRackACFault NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack + } + STATUS current + DESCRIPTION + "The designated rack signals an AC (phase) fault." + ::= { eventsTxV2 311 } + + + txRackCoolingSumFault NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack + } + STATUS current + DESCRIPTION + "The designated rack signals a summary cooling fault." + ::= { eventsTxV2 312 } + + + txRackTempFaultAbs1 NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack + } + STATUS current + DESCRIPTION + "The designated rack signals a temperature fault of absorber 1." + ::= { eventsTxV2 313 } + + + txRackTempFaultAbs2 NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack + } + STATUS current + DESCRIPTION + "The designated rack signals a temperature fault of absorber 2." + ::= { eventsTxV2 314 } + + + txRackDCFault NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack + } + STATUS current + DESCRIPTION + "The designated rack signals a DC fault." + ::= { eventsTxV2 315 } + + + txRackRfOn NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack + } + STATUS current + DESCRIPTION + "RF power is on." + ::= { eventsTxV2 318 } + + + txRackRfOk NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack + } + STATUS current + DESCRIPTION + "RF power is ok." + ::= { eventsTxV2 319 } + + + txRackRfWarning NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack + } + STATUS current + DESCRIPTION + "RF power decreased the warning threshold." + ::= { eventsTxV2 320 } + + + txRackRfFault NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack + } + STATUS current + DESCRIPTION + "RF output power decreased the fault threshold." + ::= { eventsTxV2 321 } + + + txRackReflectionWarning NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack + } + STATUS current + DESCRIPTION + "The reflected power increased the warning threshold" + ::= { eventsTxV2 322 } + + + txRackReflectionFault NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack + } + STATUS current + DESCRIPTION + "The reflected power increased the fault threshold." + ::= { eventsTxV2 323 } + + + txRackProbeNotCalibrated NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack + } + STATUS current + DESCRIPTION + "At least one probe is not calibrated." + ::= { eventsTxV2 330 } + + + txRackTemperatureWarning NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack + } + STATUS current + DESCRIPTION + "Rack temperature exceeded the warning threshold." + ::= { eventsTxV2 331 } + + + txRackOvervoltProtectWarning NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack + } + STATUS current + DESCRIPTION + "Overvoltage protection is out of order." + ::= { eventsTxV2 335 } + + + txAmpSumFault NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack, + indexAmplifier } + STATUS current + DESCRIPTION + "The designated amplifier signals summary fault." + ::= { eventsTxV2 400 } + + + txAmpSumWarning NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack, + indexAmplifier } + STATUS current + DESCRIPTION + "The designated amplifier signals summary warning." + ::= { eventsTxV2 401 } + + + txAmpPowerOn NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack, + indexAmplifier } + STATUS current + DESCRIPTION + "The designated amplifiers power is on." + ::= { eventsTxV2 402 } + + + txAmpDCOk NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack, + indexAmplifier } + STATUS current + DESCRIPTION + "The designated amplifiers DC is ok." + ::= { eventsTxV2 403 } + + + txAmpACOk NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack, + indexAmplifier } + STATUS current + DESCRIPTION + "The designated amplifiers AC is ok." + ::= { eventsTxV2 404 } + + + txAmpRfInFail NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack, + indexAmplifier } + STATUS current + DESCRIPTION + "The designated amplifier signals RF input fail." + ::= { eventsTxV2 405 } + + + txAmpRfFail NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack, + indexAmplifier } + STATUS current + DESCRIPTION + "The designated amplifier signals RF fail." + ::= { eventsTxV2 406 } + + + txAmpReflectionFault NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack, + indexAmplifier } + STATUS current + DESCRIPTION + "The designated amplifier signals a reflection fault." + ::= { eventsTxV2 407 } + + + txAmpTemperatureFault NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack, + indexAmplifier } + STATUS current + DESCRIPTION + "The designated amplifier signals a temperature fault - temperature is too high." + ::= { eventsTxV2 408 } + + + txAmpTransistorFault NOTIFICATION-TYPE + OBJECTS { eventAlarmPriority, eventAlarmClass, eventEvent, indexAB, indexRack, + indexAmplifier } + STATUS current + DESCRIPTION + "The designated amplifier signals at least one faulty transistor." + ::= { eventsTxV2 409 } + + + eventsTxTable OBJECT-TYPE + SYNTAX SEQUENCE OF EventsTxEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains necessary information for handling alarms. + For each alarm you have the following information: + - name (get), + - mask to enable/disable sending out (set/get), + - priority (set/get) and + - the current state (get only)." + ::= { eventTx 1 } + + + eventsTxEntry OBJECT-TYPE + SYNTAX EventsTxEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An event entry always consists of its indexes + (used for addressing within redundancy systems) and 3 values: + - name: an enumerated list of all possible notifications + - mask: the corresponding mask (enable/disable) + - priority: the corresponding priority (value in range 0..255) + - event: the event itself (active/inactive)" + INDEX { eventTxABIdx, eventTxRackIdx, eventTxAmpIdx, eventTxNameIdx } + ::= { eventsTxTable 1 } + + + EventsTxEntry ::= + SEQUENCE { + eventTxABIdx + INTEGER, + eventTxRackIdx + Integer32, + eventTxAmpIdx + Integer32, + eventTxNameIdx + EventMaxEntryNumber, + eventTxName + INTEGER, + eventTxMask + EventMask, + eventTxPriority + EventPriority, + eventTxEvent + EventState + } + + eventTxABIdx OBJECT-TYPE + SYNTAX INTEGER + { + a(1), + b(2) + } + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The value for the module A (exciterA, outputstageA) or + B (exciterB, outputstageB) for alarms. + This is a helper column and therefore not-accessible." + ::= { eventsTxEntry 1 } + + + eventTxRackIdx OBJECT-TYPE + SYNTAX Integer32 (1..10) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The number of the designated rack. + This is a helper column and therefore not-accessible." + ::= { eventsTxEntry 2 } + + + eventTxAmpIdx OBJECT-TYPE + SYNTAX Integer32 (1..10) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The number of the designated amplifier. + This is a helper column and therefore not-accessible." + ::= { eventsTxEntry 3 } + + + eventTxNameIdx OBJECT-TYPE + SYNTAX EventMaxEntryNumber + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The event number as integer. + This is a helper column and therefore not-accessible." + ::= { eventsTxEntry 4 } + + + eventTxName OBJECT-TYPE + SYNTAX INTEGER + { + txSummaryFault(1), + txSummaryWarning(2), + txLocal(3), + txRfOn(4), + txRfOk(5), + txParamSetSubDeviceDiffers(6), + txParamSetValuesChanged(7), + txRfLoopProgram(8), + txRfLoopReserve(9), + txRfWarning(10), + txReflectionWarning(11), + txNetCCUFanFault(12), + txNetCCUPowerSupply(13), + txRfFail(14), + txReflectionFault(15), + txNetCCUBoardTemperatureFault(16), + txNetCCUNoConnectionToExcA(17), + txNetCCUNoConnectionToOstA(18), + txNetCCUNoConnectionToExcB(19), + txNetCCUNoConnectionToOstB(20), + txAutomaticExcReady(21), + txAutomaticExcChanged(22), + txAutomaticExcFault(23), + txAutomaticOstReady(24), + txAutomaticOstChanged(25), + txAutomaticOstFault(26), + txNetCCUBoardTemperatureWarning(27), + txInternalPowerSupplyWarning(30), + txExternalPowerSupplyWarning(31), + txModeSwitchOverStarted(35), + txModeSwitchOverEnded(36), + txModeInconsistent(37), + txModeSwitchOverFailed(38), + txExcSummaryFault(100), + txExcSummaryWarning(101), + txExcLocal(102), + txExcRfOk(104), + txExcInputNoConnectHP1(105), + txExcInputNoConnectLP1(106), + txExcInputNoConnectHP2(107), + txExcInputNoConnectLP2(108), + txExcInputActiveHP1(109), + txExcInputActiveLP1(110), + txExcInputActiveHP2(111), + txExcInputActiveLP2(112), + txExcOn(113), + txExcRfOn(114), + txExcNoInput(115), + txExcRfLoop(116), + txExcRfFail(117), + txExcSelfTest(118), + txExcOutputOpen(119), + txExcBoardTemperatureWarning(120), + txExcFanWarning(121), + txExcFanFault(122), + txExcFifoWarning(123), + txExcTestSignal(124), + txExcSFNDelay(125), + txExcWrongDatarate(126), + txExcMute(127), + txExcPPSFail(128), + txExcReferenceFail(129), + txExcMIPFail(130), + txExcInputAutomaticSwitchReady(131), + txExcInputAutomaticChangedOver(132), + txExcInputReseveMissing(133), + txOstSummaryFault(200), + txOstSummaryWarning(201), + txOstRfOn(202), + txOstRfOk(203), + txOstNoInput(204), + txOstRfWarning(205), + txOstReflectionWarning(206), + txOstRackWarning(207), + txOstCoolingWarning(208), + txOstRfFail(209), + txOstReflectionFault(210), + txOstACFault(211), + txOstCoolingFault(212), + txOstCommFault(213), + txRackSumFault(300), + txRackSumWarning(301), + txRackOn(302), + txRackGpiWarning(303), + txRackFan1Fault(304), + txRackFan2Fault(305), + txRackCoolingSumWarning(306), + txRackAmplifierSumFault(307), + txRackNoLink(308), + txRackGpiFault(309), + txRackTemperatureFault(310), + txRackACFault(311), + txRackCoolingSumFault(312), + txRackTempFaultAbs1(313), + txRackTempFaultAbs2(314), + txRackDCFault(315), + txRackRfOn(318), + txRackRfOk(319), + txRackRfWarning(320), + txRackRfFault(321), + txRackReflectionWarning(322), + txRackReflectionFault(323), + txRackProbeNotCalibrated(330), + txRackTemperatureWarning(331), + txRackOvervoltProtectWarning(335), + txAmpSumFault(400), + txAmpSumWarning(401), + txAmpPowerOn(402), + txAmpDCOk(403), + txAmpACOk(404), + txAmpRfInFail(405), + txAmpRfFail(406), + txAmpReflectionFault(407), + txAmpTemperatureFault(408), + txAmpTransistorFault(409) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The event number as integer and the value as readable text. + The enumeration correlates with the notifications under eventsTxV2." + ::= { eventsTxEntry 5 } + + + eventTxMask OBJECT-TYPE + SYNTAX EventMask + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "See TextualConvention for details." + ::= { eventsTxEntry 6 } + + + eventTxPriority OBJECT-TYPE + SYNTAX EventPriority + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "See TextualConvention for details." + ::= { eventsTxEntry 7 } + + + eventTxEvent OBJECT-TYPE + SYNTAX EventState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "See TextualConvention for details." + ::= { eventsTxEntry 8 } + + +-- ***************************************************************************** +-- ** conformance statements +-- ***************************************************************************** + rsXx8000DvbTxConf OBJECT IDENTIFIER ::= { rsXx8000DvbTx 5 } + + + rsXx8000DvbTxGroups OBJECT IDENTIFIER ::= { rsXx8000DvbTxConf 1 } + + + groupEvents OBJECT-GROUP + OBJECTS { eventTxName, eventTxMask, eventTxPriority, eventTxEvent } + STATUS current + DESCRIPTION + "This group includes all OIDs for event handling." + ::= { rsXx8000DvbTxGroups 1 } + + + groupTxCommon OBJECT-GROUP + OBJECTS { cmdTxResetSumFault, cmdTxParametersetLoad, cmdTxParametersetSave, cmdTxOperationModeProgram, summaryFaultTx, + summaryWarningTx, localModeTx, rfOnTx, forwardPower, summaryFaultExcA + } + STATUS current + DESCRIPTION + "Group for common transmitter objects" + ::= { rsXx8000DvbTxGroups 2 } + + + groupEventsTxCommon NOTIFICATION-GROUP + NOTIFICATIONS { txSummaryFault, txSummaryWarning, txLocal, txRfOn, txParamSetValuesChanged, + txRfLoopProgram, txRfFail, txOstSummaryFault, txOstSummaryWarning, txRfOk, + txOstRfOn, txRfWarning } + STATUS current + DESCRIPTION + "This group includes all alarm OIDs that are common for all reserve concepts." + ::= { rsXx8000DvbTxGroups 3 } + + + groupDualDrive OBJECT-GROUP + OBJECTS { cmdTxOperationModeReserve, cmdTxOpModeExcAutomatic, cmdTxPreselectExciter, cmdTxDelayTimeExcAutomatic, exciterBNumberOfEntries, + exciterBLogbookClear, excBLogbookEntryNbr, excBLogbookType, excBLogbookSlope, excBLogbookMessage, + excBLogbookDateTime, summaryFaultExcB, exciterAutomaticReady, exciterAutomaticChanged, exciterAutomaticFault, + noConnectionExcB, activeExcA, activeExcB } + STATUS current + DESCRIPTION + "This group includes additional objects for reserve concepts + DualDrive (NetCCU + 2 * exciter + outputstage) + and + Active/Passive Reserve (NetCCU + 2 * exciter + 2 * outputstage) + " + ::= { rsXx8000DvbTxGroups 4 } + + + groupEventsDualDrive NOTIFICATION-GROUP + NOTIFICATIONS { txRfLoopReserve, txNetCCUNoConnectionToExcB, txAutomaticExcReady, txAutomaticExcChanged, txAutomaticExcFault + } + STATUS current + DESCRIPTION + "This group includes additional events for reserve concepts + DualDrive (NetCCU + 2 * exciter + outputstage) + and + Active/Passive Reserve (NetCCU + 2 * exciter + 2 * outputstage) + " + ::= { rsXx8000DvbTxGroups 5 } + + + groupPowerReserve OBJECT-GROUP + OBJECTS { cmdTxOpModeOstAutomatic, cmdTxPreselectOutputstage, cmdTxDelayTimeOstAutomatic, summaryFaultOstB, outputstageAutomaticReady, + outputstageAutomaticChanged, outputstageAutomaticFault, noConnectionOstB, activeOstA, activeOstB + } + STATUS current + DESCRIPTION + "This group includes additional objects for reserve concept + Active/Passive Reserve (NetCCU + 2 * exciter + 2 * outputstage) + For more details, refer to manual." + ::= { rsXx8000DvbTxGroups 6 } + + + groupEventsPowerReserve NOTIFICATION-GROUP + NOTIFICATIONS { txNetCCUNoConnectionToOstB, txAutomaticOstReady, txAutomaticOstChanged, txAutomaticOstFault } + STATUS current + DESCRIPTION + "This group includes additional events for reserve concept + Active/Passive Reserve (NetCCU + 2 * exciter + 2 * outputstage) + For more details, refer to manual." + ::= { rsXx8000DvbTxGroups 7 } + + + groupCommonMP OBJECT-GROUP + OBJECTS { cmdOstRefVoltageVision, cmdOstMaxOutletTempThreshold, outputstageANumberOfEntries, outputstageALogbookClear, ostALogbookEntryNbr, + ostALogbookType, ostALogbookSlope, ostALogbookMessage, ostALogbookDateTime, reflectedPower, + ostRackInletTemperature, ostRackOutletTemperature, ostRackAuxPowerSupply, amplifiersPerRack, rackRfEventSignalling, + rackGeneralPurposeInput, rfProbePresent, rfProbeConfigurationNominalValue, rfProbeThresholdRfFailLimit, rfProbeThresholdTimeoutRfFailCtr, + rfProbeThresholdWarningLimit, rfProbeCalibrationGain, rfProbeCalibrationOffset, rfProbeCalibrationSetGain, rfProbeCalibrationSetOffset, + rfProbeMeasuredValue } + STATUS current + DESCRIPTION + "additional objects for medium/high power" + ::= { rsXx8000DvbTxGroups 8 } + + + groupEventsCommonMP NOTIFICATION-GROUP + NOTIFICATIONS { txReflectionWarning, txReflectionFault, txOstRfOk, txOstNoInput, txOstRfWarning, + txOstReflectionWarning, txOstRackWarning, txOstCoolingWarning, txOstRfFail, txOstReflectionFault, + txOstACFault, txOstCoolingFault, txOstCommFault, txRackSumFault, txRackSumWarning, + txRackOn, txRackGpiWarning, txRackFan1Fault, txRackFan2Fault, txRackCoolingSumWarning, + txRackAmplifierSumFault, txRackNoLink, txRackGpiFault, txRackTemperatureFault, txRackACFault, + txRackCoolingSumFault, txRackTempFaultAbs1, txRackTempFaultAbs2, txRackDCFault, txRackRfWarning, + txRackRfFault, txRackReflectionWarning, txRackReflectionFault, txRackRfOk, txRackRfOn, + txRackOvervoltProtectWarning, txRackTemperatureWarning, txRackProbeNotCalibrated } + STATUS current + DESCRIPTION + "additional events for medium/high power" + ::= { rsXx8000DvbTxGroups 9 } + + + groupCommonNetCCU OBJECT-GROUP + OBJECTS { netCCUNumberOfEntries, netCCULogbookClear, netCCULogbookEntryNbr, netCCULogbookType, netCCULogbookSlope, + netCCULogbookMessage, netCCULogbookDateTime, powerSupply, cmdTxSystemMode, additionalPowerSupply, + summaryFaultOstA, noConnectionExcA, noConnectionOstA } + STATUS current + DESCRIPTION + "additional objects for transmitters with NetCCU" + ::= { rsXx8000DvbTxGroups 10 } + + + groupEventsCommonNetCCU NOTIFICATION-GROUP + NOTIFICATIONS { txNetCCUFanFault, txNetCCUPowerSupply, txNetCCUNoConnectionToExcA, txNetCCUNoConnectionToOstA, txModeSwitchOverStarted, + txModeSwitchOverEnded, txModeInconsistent, txModeSwitchOverFailed, txNetCCUBoardTemperatureWarning } + STATUS current + DESCRIPTION + "additional events for transmitters with NetCCU" + ::= { rsXx8000DvbTxGroups 11 } + + + groupOstBLogbook OBJECT-GROUP + OBJECTS { outputstageBNumberOfEntries, outputstageBLogbookClear, ostBLogbookEntryNbr, ostBLogbookType, ostBLogbookSlope, + ostBLogbookMessage, ostBLogbookDateTime } + STATUS current + DESCRIPTION + "objects of logbook for output stage B" + ::= { rsXx8000DvbTxGroups 12 } + + + groupSumProbe OBJECT-GROUP + OBJECTS { forwardPowerOstA, reflectedPowerOstA, forwardPowerOstB, reflectedPowerOstB } + STATUS current + DESCRIPTION + "objects that are available only when sum probe exists" + ::= { rsXx8000DvbTxGroups 14 } + + + groupProductInfo OBJECT-GROUP + OBJECTS { prodInfoModuleName, prodInfoSerialNumber, prodInfoIdentNumberSW, prodInfoVersionNumberSW, productInfoProductDateHW, + prodInfoIdentNumberHW, prodInfoVersionNumberHW } + STATUS current + DESCRIPTION + "This group includes all OIDs for device product information." + ::= { rsXx8000DvbTxGroups 18 } + + + groupAmpMeasureValues OBJECT-GROUP + OBJECTS { ostRackAmpI1A, ostRackAmpI2A, ostRackAmpI3A, ostRackAmpI4A, ostRackAmpI1B, + ostRackAmpI2B, ostRackAmpI3B, ostRackAmpI4B, ostRackAmpIDrv, ostRackAmpUDc, + ostRackAmpIDc, ostRackAmpUDcControl, ostRackAmpUReg, ostRackAmpPowerA, ostRackAmpPowerB, + ostRackAmpPowerOut, ostRackAmpPowerReflection, ostRackAmpPowerReference, ostRackAmpDeltaPhase, ostRackAmpCmdDeltaPhase + } + STATUS current + DESCRIPTION + "This group includes all OIDs amplifier measure values. + Practically, these information are not important to customers, they are needed in manufactory." + ::= { rsXx8000DvbTxGroups 19 } + + + groupEventsAmplifier NOTIFICATION-GROUP + NOTIFICATIONS { txAmpSumFault, txAmpSumWarning, txAmpPowerOn, txAmpDCOk, txAmpACOk, + txAmpRfInFail, txAmpRfFail, txAmpReflectionFault, txAmpTemperatureFault, txAmpTransistorFault + } + STATUS current + DESCRIPTION + "events from the amplifier (medium/high power only)" + ::= { rsXx8000DvbTxGroups 20 } + + + groupRfProbes OBJECT-GROUP + OBJECTS { rfProbesNetCCURfProbe1, rfProbesNetCCURfProbe2, rfProbesAntFwdNominal, rfProbesAntFwdWarningLimit, rfProbesAntFwdFailLimit, + rfProbesAntFwdDelayTimeRfFail, rfProbesAntFwdSetOffset, rfProbesAntFwdSetGain, rfProbesAntReflWarningLimit, rfProbesAntReflSetOffset, + rfProbesAntReflSetGain, rfProbesOstFwdNominal, rfProbesOstFwdWarningLimit, rfProbesOstFwdFailLimit, rfProbesOstFwdDelayTimeRfFail, + rfProbesOstFwdSetOffset, rfProbesOstFwdSetGain, rfProbesOstReflWarningLimit, rfProbesOstReflSetOffset, rfProbesOstReflSetGain + } + STATUS current + DESCRIPTION + "This group includes all OIDs regarding RF Probes." + ::= { rsXx8000DvbTxGroups 21 } + + + groupDummyLoadRF OBJECT-GROUP + OBJECTS { rfProbesDLFwdNominal, rfProbesDLFwdWarningLimit, rfProbesDLFwdFailLimit, rfProbesDLFwdDelayTimeRfFail, rfProbesDLFwdSetOffset, + rfProbesDLFwdSetGain, rfProbesDLReflWarningLimit, rfProbesDLReflSetOffset, rfProbesDLReflSetGain } + STATUS current + DESCRIPTION + "This group includes all object types regarding probes from dummy load. + The object types in this group are defined only when a dummy load measure point exists. + This can occur in reserve concept active reserve only. + " + ::= { rsXx8000DvbTxGroups 22 } + + + groupExcCommon OBJECT-GROUP + OBJECTS { cmdExcOpModeInputAutomatic, cmdExcPreselectInput, cmdExcMode, cmdExcNetworkMode, cmdExcTPSSource, + cmdExcEnableCellID, cmdExcTxAddress, cmdExcTxAutomatic, cmdExcInputSeamless, cmdExcInputPriority, + cmdExcInputCheckTimeForward, cmdExcInputCheckTimeSwitchback, cmdExcInputMuteOnFail, cmdExcInputManualPreseletionHP1, cmdExcInputManualPreseletionHP2, + cmdExcInputManualPreseletionLP1, cmdExcInputManualPreseletionLP2, cmdExcTPSManualBandwidth, cmdExcTPSManualFFTLength, cmdExcTPSManualGuardInterval, + cmdExcTPSManualConstellation, cmdExcTPSManualCellID, cmdExcTPSManualInterleaver, cmdExcTPSManualCoderateHP, cmdExcTPSManualCoderateLP, + cmdExcTPSManualTimeSlicingHP, cmdExcTPSManualTimeSlicingLP, cmdExcTPSManualFECHP, cmdExcTPSManualFECLP, cmdExcSFNStaticDelay, + cmdExcSFNDeviationTime, cmdExcFrequency, cmdExcReferenceSource, cmdExcMuteOnPPSFail, cmdExcMuteOnReferenceFail, + cmdExcTypeLossOfInput, cmdExcRfOutput, cmdExcRfOutputAttenuation, cmdExcRfOutputRfSlope, cmdExcRfOutputModulationSlope, + cmdExcRfIqAdjustTestsignal, cmdExcRfIqAdjustBiasCoarseI, cmdExcRfIqAdjustBiasCoarseQ, cmdExcRfIqAdjustBiasFineI, cmdExcRfIqAdjustBiasFineQ, + cmdExcRfIqAdjustGainI, cmdExcRfIqAdjustGainQ, cmdExcRfIqAdjustPhase, cmdExcInpAutoReadyAfterChangeOv, excInputChannelName, + excInputConnected, excInputSeamless, excInputPreselected, excInputActive, excInputMipFail, + excInputBandwidth, excInputFFTLength, excInputGuardInterval, excInputConstellation, excInputCellID, + excInputInterleaver, excInputCodeRate, excInputPacketLength, excInputMeasuredDatarate, excInputRequiredDatarate, + excInputMaximumDelay, exciterANumberOfEntries, exciterALogbookClear, excALogbookEntryNbr, excALogbookType, + excALogbookSlope, excALogbookMessage, excALogbookDateTime, cmdExcOcxoAdjust, cmdExcExpectInputReserve, + excStatusReqDataRateLP, excStatusReqDataRateHP, excStatusAmplifierControl, excStatusFailDelay, cmdExcFailDelayMode, + cmdExcInputFailDelayTime, cmdExcRefFailDelayTime } + STATUS current + DESCRIPTION + "Group for common exciter objects" + ::= { rsXx8000DvbTxGroups 23 } + + + groupExcAdditionalSx800 OBJECT-GROUP + OBJECTS { cmdExcRfOutputRegulation, cmdExcRfOutputManualRfLevel, cmdExcRfIqAdjustStart } + STATUS current + DESCRIPTION + "Additional exciter objects for the Sx800" + ::= { rsXx8000DvbTxGroups 24 } + + + groupExcAdditionalSLx OBJECT-GROUP + OBJECTS { cmdExcInput1Source, cmdExcInput2Source } + STATUS current + DESCRIPTION + "Additional exciter objects for the SLx and the Sx801" + ::= { rsXx8000DvbTxGroups 25 } + + + groupEventsExciter NOTIFICATION-GROUP + NOTIFICATIONS { txExcSummaryFault, txExcSummaryWarning, txExcInputNoConnectHP1, txExcInputNoConnectLP1, txExcInputNoConnectHP2, + txExcInputNoConnectLP2, txExcInputActiveHP1, txExcInputActiveLP1, txExcInputActiveHP2, txExcInputActiveLP2, + txExcOn, txExcRfOn, txExcNoInput, txExcRfLoop, txExcRfFail, + txExcSelfTest, txExcOutputOpen, txExcBoardTemperatureWarning, txExcFanWarning, txExcFanFault, + txExcFifoWarning, txExcTestSignal, txExcSFNDelay, txExcWrongDatarate, txExcMute, + txExcPPSFail, txExcReferenceFail, txExcMIPFail, txExcInputAutomaticSwitchReady, txExcRfOk, + txExcInputReseveMissing, txExcInputAutomaticChangedOver, txExcLocal } + STATUS current + DESCRIPTION + "events from the exciter" + ::= { rsXx8000DvbTxGroups 26 } + + + groupExciterStatus OBJECT-GROUP + OBJECTS { excStatusRfOutputAgcRegulation, excStatusRfIqAdjustAuto, excStatusRfIqAdjustLO1Frequency, excStatusSfnDelayProcessing, excStatusSfnDelayDynamic, + excStatusSfnDelayNetwork, excStatusSfnDelayTxOffset, excStatusSfnDelayMaximum, excStatusSfnDelayTotal, excStatusNominalPower + } + STATUS current + DESCRIPTION + "Group for exciterStatusTable." + ::= { rsXx8000DvbTxGroups 27 } + + + groupExciterPrecorrection OBJECT-GROUP + OBJECTS { excPrecLinCorrection, excPrecLinAutomaticADE, excPrecLinMaxAmplitudeRipple, excPrecLinMaxGroupDelayRipple, excPrecLinAmplitudeRipple, + excPrecLinGroupDelayRipple, excPrecLinInputLevel, excPrecLinAutomatic, excPrecNonlinCorrection, excPrecNonlinAutomaticADE, + excPrecNonlinThresholdShoulders, excPrecNonlinShoulderLeft, excPrecNonlinShoulderRight, excPrecNonlinInputLevel, excPrecNonlinAutomatic + } + STATUS current + DESCRIPTION + "Group for exciterPrecorrectionTable." + ::= { rsXx8000DvbTxGroups 28 } + + + groupSLx OBJECT-GROUP + OBJECTS { cmdExcTransmitterType, cmdExcTimeScheduler, excPrecUserState, excPrecFactoryState, excPrecRestoreCurrentSettings, + excPrecRestoreAllSettings, configTvStandardName, configFrequency, configPower, schedulerRowStatus, + schedulerEvent, schedulerDateTime, config2InputSource, config2Power, config2Frequency, + config2RxFrequency, config2TvStandardName, excStatusVSWR, cmdExcMuteCondition, schedulerTvStandard, + configRxFrequency, configInputSource } + STATUS current + DESCRIPTION + "object types that are relevant for SLx devices only" + ::= { rsXx8000DvbTxGroups 29 } + + + groupObjectsACU OBJECT-GROUP + OBJECTS { cmdExcRfWarningLimit, cmdExcRfFailLimit, cmdExcOutputPower, cmdExcMonitoringOutput } + STATUS current + DESCRIPTION + "objects from ACU" + ::= { rsXx8000DvbTxGroups 30 } + + + groupIndependentRacks OBJECT-GROUP + OBJECTS { rackReferenceVoltage, amplifiersPowerSupply, rackOnOff } + STATUS current + DESCRIPTION + "object types that are relevant for NX variants with independent racks only" + ::= { rsXx8000DvbTxGroups 31 } + + + groupObjectsRE OBJECT-GROUP + OBJECTS { summaryFaultExcA } + STATUS current + DESCRIPTION + "object types for the re-equip kit" + ::= { rsXx8000DvbTxGroups 32 } + + + groupEventsControlExciter NOTIFICATION-GROUP + NOTIFICATIONS { txNetCCUNoConnectionToExcB, txAutomaticExcReady, txAutomaticExcChanged, txAutomaticExcFault } + STATUS current + DESCRIPTION + "additional events in case Sx801 is control exciter" + ::= { rsXx8000DvbTxGroups 34 } + + + groupEventsAdditionalPowerSupply NOTIFICATION-GROUP + NOTIFICATIONS { txInternalPowerSupplyWarning, txExternalPowerSupplyWarning } + STATUS current + DESCRIPTION + "Events that are available only when additionalPowerSupply is true." + ::= { rsXx8000DvbTxGroups 35 } + + + groupObjsAdditionalPowerSupply OBJECT-GROUP + OBJECTS { internalPowerSupply, externalPowerSupply } + STATUS current + DESCRIPTION + "Objects that are available only when additionalPowerSupply is true." + ::= { rsXx8000DvbTxGroups 36 } + + + groupObjectsControlExciter OBJECT-GROUP + OBJECTS { cmdTxOperationModeReserve, cmdTxOpModeExcAutomatic, cmdTxDelayTimeExcAutomatic, summaryFaultExcB, exciterAutomaticReady, + exciterAutomaticChanged, exciterAutomaticFault, noConnectionExcB, activeExcB, cmdTxProgramExciterPrio, + cmdTxChangeOver, cmdTxSwitchPosition } + STATUS current + DESCRIPTION + "additional objects in case Sx801 is control exciter" + ::= { rsXx8000DvbTxGroups 37 } + + + groupObjectsSingleEnded OBJECT-GROUP + OBJECTS { cmdTxRfSwitch } + STATUS current + DESCRIPTION + "Group for objects in case of SingleTx or DualDrive." + ::= { rsXx8000DvbTxGroups 38 } + + + groupObjectsSx801Amplifier OBJECT-GROUP + OBJECTS { sx801AmpRfOut, sx801AmpRfIn, sx801AmpReflection, sx801AmpOn, sx801AmpAC, + sx801AmpCommunication, sx801AmpTransistor, sx801AmpDriver, sx801AmpTemperature, sx801AmpBlower, + sx801AmpRegulation, sx801AmpUpdate, sx801Supply1Temperature, sx801Supply2Temperature, sx801SupplyRTemperature, + sx801Supply1DC, sx801Supply2DC, sx801SupplyRDC, sx801AmpValueI1, sx801AmpValueI2, + sx801AmpValueI3, sx801AmpValueI4, sx801AmpValueIPre, sx801AmpValueIDrv1, sx801AmpValueIDrv2, + sx801AmpValuePowerOut, sx801AmpValueReflection, sx801AmpValueVRef, sx801AmpValueVReg, sx801AmpValueTemperature, + sx801AmpValueMonAtt, sx801AmpValueVAux1, sx801AmpValueVAux2, sx801Supply1ValuePwr, sx801Supply2ValuePwr, + sx801Supply1ValueDc, sx801Supply2ValueDc } + STATUS current + DESCRIPTION + "Objects for Sx801/SA801 amplifier status." + ::= { rsXx8000DvbTxGroups 39 } + + + groupObsoleted OBJECT-GROUP + OBJECTS { cmdTxParametersetReSave, cmdExcTimeForDailyPcrReset, cmdExcEnablePcrReset, excInputAlpha, cmdExcTPSManualAlpha, + rfProbeConfigurationLabel, cmdExcInputAutoSwitch } + STATUS obsolete + DESCRIPTION + "obsoleted or deprecated objects" + ::= { rsXx8000DvbTxGroups 99 } + + + groupEventsObsoleted NOTIFICATION-GROUP + NOTIFICATIONS { txParamSetSubDeviceDiffers, txNetCCUBoardTemperatureFault } + STATUS obsolete + DESCRIPTION + "obsoleted or deprecated events" + ::= { rsXx8000DvbTxGroups 100 } + + + rsXx8000DvbTxCompl OBJECT IDENTIFIER ::= { rsXx8000DvbTxConf 3 } + + + rsXx8000DVBSingleTxMP MODULE-COMPLIANCE + STATUS current + DESCRIPTION + "Reserve concept SingleTransmitter for Medium Power." + MODULE -- this module + MANDATORY-GROUPS { groupTxCommon, groupCommonMP, groupCommonNetCCU, groupExcCommon, groupEvents, + groupProductInfo, groupRfProbes, groupExciterStatus, groupExciterPrecorrection, groupEventsExciter, + groupEventsCommonNetCCU, groupObjectsSingleEnded, groupEventsCommonMP, groupEventsTxCommon } + GROUP groupIndependentRacks + DESCRIPTION + "for variant with independent racks only" + OBJECT cmdOstRefVoltageVision + MIN-ACCESS not-accessible + DESCRIPTION + "not accessible in variant with independent racks" + GROUP groupExcAdditionalSx800 + DESCRIPTION + "in case of Sx800 exciter" + GROUP groupEventsAdditionalPowerSupply + DESCRIPTION + "only when additionalPowerSupply is true" + GROUP groupAmpMeasureValues + DESCRIPTION + "not for face-lift configuration" + GROUP groupEventsAmplifier + DESCRIPTION + "not for face-lift configuration" + GROUP groupObjsAdditionalPowerSupply + DESCRIPTION + "only when additionalPowerSupply is true" + ::= { rsXx8000DvbTxCompl 1 } + + + rsXx8000DVBDualDriveMP MODULE-COMPLIANCE + STATUS current + DESCRIPTION + "Reserve concept DualDrive for Medium Power." + MODULE -- this module + MANDATORY-GROUPS { groupTxCommon, groupCommonMP, groupCommonNetCCU, groupExcCommon, groupDualDrive, + groupEvents, groupProductInfo, groupRfProbes, groupExciterStatus, groupExciterPrecorrection, + groupEventsExciter, groupEventsCommonNetCCU, groupEventsCommonMP, groupObjectsSingleEnded, groupEventsDualDrive, + groupEventsTxCommon } + GROUP groupIndependentRacks + DESCRIPTION + "for variant with independent racks only" + OBJECT cmdOstRefVoltageVision + MIN-ACCESS not-accessible + DESCRIPTION + "not accessible in variant with independent racks" + GROUP groupExcAdditionalSx800 + DESCRIPTION + "in case of Sx800 exciter" + GROUP groupEventsAdditionalPowerSupply + DESCRIPTION + "only when additionalPowerSupply is true" + GROUP groupAmpMeasureValues + DESCRIPTION + "not for face-lift configuration" + GROUP groupEventsAmplifier + DESCRIPTION + "not for face-lift configuration" + GROUP groupObjsAdditionalPowerSupply + DESCRIPTION + "only when additionalPowerSupply is true" + ::= { rsXx8000DvbTxCompl 2 } + + + rsXx8000DVBPowerReserveMP MODULE-COMPLIANCE + STATUS current + DESCRIPTION + "Reserve concept Active/Passive Reserve for Medium Power." + MODULE -- this module + MANDATORY-GROUPS { groupTxCommon, groupEvents, groupProductInfo, groupRfProbes, groupExciterStatus, + groupExcCommon, groupExciterPrecorrection, groupDualDrive, groupPowerReserve, groupCommonMP, + groupCommonNetCCU, groupOstBLogbook, groupEventsExciter, groupEventsCommonNetCCU, groupEventsCommonMP, + groupEventsPowerReserve, groupEventsDualDrive, groupEventsTxCommon } + GROUP groupIndependentRacks + DESCRIPTION + "for variant with independent racks only" + OBJECT cmdOstRefVoltageVision + MIN-ACCESS not-accessible + DESCRIPTION + "not accessible in variant with independent racks" + GROUP groupSumProbe + DESCRIPTION + "when sum probe exists only" + GROUP groupExcAdditionalSx800 + DESCRIPTION + "in case of Sx800 exciter" + GROUP groupEventsAdditionalPowerSupply + DESCRIPTION + "only when additionalPowerSupply is true" + GROUP groupAmpMeasureValues + DESCRIPTION + "not for face-lift configuration" + GROUP groupEventsAmplifier + DESCRIPTION + "not for face-lift configuration" + GROUP groupObjsAdditionalPowerSupply + DESCRIPTION + "only when additionalPowerSupply is true" + GROUP groupDummyLoadRF + DESCRIPTION + "only when a dummy load measure point exists" + ::= { rsXx8000DvbTxCompl 3 } + + + rsXx8000DVBSingleTxLP MODULE-COMPLIANCE + STATUS current + DESCRIPTION + "Reserve concept Low Power SingleTransmitter with NetCCU, meaning there is a NetCCU and a + LowPower exciter with one or more (to the exciter) connected amplifiers." + MODULE -- this module + MANDATORY-GROUPS { groupEvents, groupExciterStatus, groupExciterPrecorrection, groupExcAdditionalSLx, groupExcCommon, + groupCommonNetCCU, groupTxCommon, groupEventsExciter, groupEventsCommonNetCCU, groupEventsTxCommon + } + GROUP groupEventsAdditionalPowerSupply + DESCRIPTION + "only when additionalPowerSupply is true" + GROUP groupObjsAdditionalPowerSupply + DESCRIPTION + "only when additionalPowerSupply is true" + ::= { rsXx8000DvbTxCompl 5 } + + + rsXx8000DVBDualDriveLP MODULE-COMPLIANCE + STATUS current + DESCRIPTION + "Reserve concept DualDrive for Low Power." + MODULE -- this module + MANDATORY-GROUPS { groupEvents, groupExciterStatus, groupExciterPrecorrection, groupExcAdditionalSLx, groupExcCommon, + groupCommonNetCCU, groupDualDrive, groupTxCommon, groupEventsExciter, groupEventsCommonNetCCU, + groupEventsDualDrive, groupEventsTxCommon } + GROUP groupEventsAdditionalPowerSupply + DESCRIPTION + "only when additionalPowerSupply is true" + GROUP groupObjsAdditionalPowerSupply + DESCRIPTION + "only when additionalPowerSupply is true" + ::= { rsXx8000DvbTxCompl 6 } + + + rsXx8000DVBPowerReserveLP MODULE-COMPLIANCE + STATUS current + DESCRIPTION + "Reserve concept Active/Passive Reserve for Low Power." + MODULE -- this module + MANDATORY-GROUPS { groupEvents, groupExciterStatus, groupExciterPrecorrection, groupExcAdditionalSLx, groupExcCommon, + groupCommonNetCCU, groupPowerReserve, groupDualDrive, groupTxCommon, groupEventsExciter, + groupEventsCommonNetCCU, groupEventsPowerReserve, groupEventsDualDrive, groupEventsTxCommon } + GROUP groupEventsAdditionalPowerSupply + DESCRIPTION + "only when additionalPowerSupply is true" + GROUP groupObjsAdditionalPowerSupply + DESCRIPTION + "only when additionalPowerSupply is true" + ::= { rsXx8000DvbTxCompl 7 } + + + rsXx8000DVBSingleTxLPNoNetCCU MODULE-COMPLIANCE + STATUS current + DESCRIPTION + "Reserve concept Low Power SingleTransmitter without NetCCU, meaning there is only a + LowPower exciter with one or more (to the exciter) connected amplifiers." + MODULE -- this module + MANDATORY-GROUPS { groupEvents, groupExciterStatus, groupExciterPrecorrection, groupExcAdditionalSLx, groupExcCommon, + groupTxCommon, groupEventsExciter, groupEventsTxCommon } + ::= { rsXx8000DvbTxCompl 9 } + + + rsXx8000DVBSLx MODULE-COMPLIANCE + STATUS current + DESCRIPTION + "SLx device" + MODULE -- this module + MANDATORY-GROUPS { groupEvents, groupExciterStatus, groupExciterPrecorrection, groupSLx, groupObjectsACU, + groupExcCommon, groupTxCommon, groupEventsExciter, groupEventsTxCommon } + ::= { rsXx8000DvbTxCompl 10 } + + + rsXx8000DVBExciterOnly MODULE-COMPLIANCE + STATUS current + DESCRIPTION + "DVB Exciter of 8000 series in a 7000 environment + or + Program Exciter in a Sx801 Backup Exciter environment." + MODULE -- this module + MANDATORY-GROUPS { groupProductInfo, groupExciterStatus, groupEvents, groupObjectsRE, groupObjectsSx801Amplifier, + groupExciterPrecorrection, groupExcCommon, groupEventsExciter } + GROUP groupSLx + DESCRIPTION + "in case of SLx device" + ::= { rsXx8000DvbTxCompl 11 } + + + rsXx8000DVBSx801ControlExciter MODULE-COMPLIANCE + STATUS current + DESCRIPTION + "Sx801 as control exciter" + MODULE -- this module + MANDATORY-GROUPS { groupTxCommon, groupExcCommon, groupEvents, groupExciterStatus, groupExciterPrecorrection, + groupSLx, groupObjectsACU, groupObjectsSx801Amplifier, groupEventsExciter, groupEventsTxCommon, + groupEventsControlExciter, groupObjectsControlExciter } + ::= { rsXx8000DvbTxCompl 12 } + + + + END |