summaryrefslogtreecommitdiff
path: root/MIBS/radlan/RADLAN-PHY-MIB
diff options
context:
space:
mode:
authorDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
committerDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
commit98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch)
tree9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/radlan/RADLAN-PHY-MIB
downloadmibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.tar.gz
mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.zip
Initial commitHEADmain
Diffstat (limited to 'MIBS/radlan/RADLAN-PHY-MIB')
-rw-r--r--MIBS/radlan/RADLAN-PHY-MIB222
1 files changed, 222 insertions, 0 deletions
diff --git a/MIBS/radlan/RADLAN-PHY-MIB b/MIBS/radlan/RADLAN-PHY-MIB
new file mode 100644
index 0000000..11ce15e
--- /dev/null
+++ b/MIBS/radlan/RADLAN-PHY-MIB
@@ -0,0 +1,222 @@
+RADLAN-PHY-MIB DEFINITIONS ::= BEGIN
+
+-- Title: RADLAN PHY MIB
+-- Version: 7.38
+-- Date: 10 Sep 2004
+--
+IMPORTS
+ OBJECT-TYPE, MODULE-IDENTITY FROM SNMPv2-SMI
+ ifIndex FROM IF-MIB
+ TimeStamp, DisplayString FROM SNMPv2-TC
+ rnd FROM RADLAN-MIB
+ TEXTUAL-CONVENTION FROM SNMPv2-TC;
+
+ rlPhy MODULE-IDENTITY
+ LAST-UPDATED "200209300024Z" -- September 30, 2002
+ ORGANIZATION "Radlan Computer Communication Ltd."
+ CONTACT-INFO
+ "radlan.com"
+ DESCRIPTION
+ "The MIB module describes the private MIB for testing Layer1 interfaces supported
+ by Radlan's software and products."
+ REVISION "200209300024Z" -- September 30, 2002
+ DESCRIPTION
+ "Initial revision"
+ REVISION "200309210024Z" -- September 21, 2003
+ DESCRIPTION
+ "Added MODULE-IDENTITY and TEXTUAL-CONVENTION IMPORTS."
+ ::= { rnd 90 }
+
+
+RlPhyTestType ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "A value indicating the test to perform."
+ SYNTAX INTEGER {
+ rlPhyTestTableNoTest(1),
+ rlPhyTestTableCableStatus(2),
+ rlPhyTestTableCableFault(3),
+ rlPhyTestTableCableLength(4),
+ rlPhyTestTableTransceiverTemp(5),
+ rlPhyTestTableTransceiverSupply(6),
+ rlPhyTestTableTxBias(7),
+ rlPhyTestTableTxOutput(8),
+ rlPhyTestTableRxOpticalPower(9),
+ rlPhyTestTableDataReady(10),
+ rlPhyTestTableLOS(11),
+ rlPhyTestTableTxFault(12),
+ rlPhyTestTableCableChannel1(13),
+ rlPhyTestTableCableChannel2(14),
+ rlPhyTestTableCableChannel3(15),
+ rlPhyTestTableCableChannel4(16),
+ rlPhyTestTableCablePolarity1(17),
+ rlPhyTestTableCablePolarity2(18),
+ rlPhyTestTableCablePolarity3(19),
+ rlPhyTestTableCablePolarity4(20),
+ rlPhyTestTableCablePairSkew1(21),
+ rlPhyTestTableCablePairSkew2(22),
+ rlPhyTestTableCablePairSkew3(23),
+ rlPhyTestTableCablePairSkew4(24)
+ }
+
+rlPhyTest OBJECT IDENTIFIER ::= { rlPhy 1 }
+
+rlPhyTestSetTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RlPhyTestSetEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION ""
+ ::= { rlPhyTest 1}
+
+rlPhyTestSetEntry OBJECT-TYPE
+ SYNTAX RlPhyTestSetEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing objects for invoking tests on an interface."
+ INDEX {ifIndex }
+ ::= { rlPhyTestSetTable 1 }
+
+RlPhyTestSetEntry ::=
+ SEQUENCE {
+ rlPhyTestSetType RlPhyTestType
+ }
+
+rlPhyTestSetType OBJECT-TYPE
+ SYNTAX RlPhyTestType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A control variable used to start operator initiated interface
+ tests.1 indicates that no test has been initiated. Only
+ operator initiated interface tests can be set to this variable."
+ ::= { rlPhyTestSetEntry 1 }
+
+rlPhyTestGetTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RlPhyTestGetEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION ""
+ ::= { rlPhyTest 2 }
+
+rlPhyTestGetEntry OBJECT-TYPE
+ SYNTAX RlPhyTestGetEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry containing results of tests on an interface."
+ INDEX {ifIndex, rlPhyTestGetType}
+ ::= { rlPhyTestGetTable 1 }
+
+RlPhyTestGetEntry ::=
+ SEQUENCE {
+ rlPhyTestGetType RlPhyTestType,
+ rlPhyTestGetStatus INTEGER,
+ rlPhyTestGetResult INTEGER,
+ rlPhyTestGetUnits INTEGER,
+ rlPhyTestGetAlarm INTEGER,
+ rlPhyTestGetTimeStamp DisplayString
+ }
+
+rlPhyTestGetType OBJECT-TYPE
+ SYNTAX RlPhyTestType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A control variable used to, 1 to indicate that this test can be
+ done on the specified port, 2 to initiate the test whenever the
+ user wishes"
+ ::= { rlPhyTestGetEntry 1 }
+
+rlPhyTestGetStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(1), -- no test yet requested
+ success(2),
+ inProgress(3),
+ notSupported(4),
+ unAbleToRun(5), -- due to state of system
+ aborted(6),
+ failed(7)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object contains the status of the most recently
+ requested test for operator initiated tests or the value
+ none(1) if no tests have been requested since the last
+ reset. For non operator initiated tests the value is always
+ none(1).
+ Note that this facility provides no provision for saving
+ the results of one test when starting another, as could
+ be required if used by multiple managers concurrently."
+ ::= { rlPhyTestGetEntry 2 }
+
+rlPhyTestGetResult OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object holds the test result"
+ ::= { rlPhyTestGetEntry 3 }
+
+rlPhyTestGetUnits OBJECT-TYPE
+ SYNTAX INTEGER {
+ integer(1),
+ boolean(2),
+ downUP(3),
+ reverseNormal(4),
+ mdiMdix(5),
+ meter(6),
+ degree(7), -- Celsius
+ microVolt(8),
+ microOham(9),
+ microAmper(10),
+ microWatt(11),
+ millisecond(12),
+ alaskaPhyLength(13),
+ alaskaPhyStatus(14),
+ dbm(15),
+ decidbm(16),
+ milidbm(17),
+ abcd(18),
+ nanosecond(19)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The test result unit of measure. The units can be standard unit or special units
+ that are designed for special test.
+
+ The alaskaPhyLength unit is design for the VCT diagnostic and its values are:
+ less_than_50M(1), 50-80M(2), 80-110M(3), 110-140M(4), more_than_140M(5).
+
+ The alaskaPhyStatus unit is design for the VCT diagnostic and its values are:
+ 4_pair_cable(1), 2_pair_cable(2), no_cable(3), open_cable(4), short_cable(5), bad_cable(6), impedance_mismatch(7)."
+ ::= { rlPhyTestGetEntry 4 }
+
+rlPhyTestGetAlarm OBJECT-TYPE
+ SYNTAX INTEGER {
+ notRelevant(1),
+ noAlarmSet(2),
+ lowWarning(3),
+ highWarning(4),
+ lowAlarm(5),
+ highAlarm(6)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object hold the Alarm for this Entry. only Test that have can have alarms
+ use this field, other holds the Value notRelevant(1) "
+ ::= { rlPhyTestGetEntry 5 }
+
+rlPhyTestGetTimeStamp OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(1..32))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The time in string (formated DD-MMM-YYYY HH:MM:SS e.g
+ 14-Apr-2002 10:33:31)"
+ ::= { rlPhyTestGetEntry 6 }
+
+END