diff options
| author | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
|---|---|---|
| committer | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
| commit | 98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch) | |
| tree | 9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/quanta/sflow.my | |
| download | mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.tar.gz mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.zip | |
Diffstat (limited to 'MIBS/quanta/sflow.my')
| -rw-r--r-- | MIBS/quanta/sflow.my | 535 |
1 files changed, 535 insertions, 0 deletions
diff --git a/MIBS/quanta/sflow.my b/MIBS/quanta/sflow.my new file mode 100644 index 0000000..cc03d77 --- /dev/null +++ b/MIBS/quanta/sflow.my @@ -0,0 +1,535 @@ +SFLOW-MIB DEFINITIONS ::= BEGIN + +IMPORTS + + MODULE-IDENTITY, OBJECT-TYPE, Integer32, enterprises + FROM SNMPv2-SMI + TEXTUAL-CONVENTION + FROM SNMPv2-TC + SnmpAdminString + FROM SNMP-FRAMEWORK-MIB + OwnerString + FROM RMON-MIB + InetAddressType, InetAddress + FROM INET-ADDRESS-MIB + MODULE-COMPLIANCE, OBJECT-GROUP + FROM SNMPv2-CONF; + + sFlowMIB MODULE-IDENTITY + LAST-UPDATED "200309240000Z" -- September 24, 2003 + ORGANIZATION "Netgear Inc" + CONTACT-INFO "" + + DESCRIPTION + "The MIB module for managing the generation and transportation + of sFlow data records." + + -- + -- Revision History + -- + + REVISION "200310180000Z" -- November 18, 2003 + DESCRIPTION + "Version 1.3 (draft 5) + + Allow set to SFlowReceiver if it doesn't change + value." + + REVISION "200309240000Z" -- September 24, 2003 + DESCRIPTION + "Version 1.3 (draft 4) + + Default value of sFlowRcvrAddress should be '00000000' h. + Default value of sFlowCpReceiver should be 0." + + REVISION "200304080000Z" -- April 8, 2003 + DESCRIPTION + "Version 1.3 (draft 3) + + Clarify semantics of counter polling interval, + sFlowCpInterval." + + REVISION "200209170000Z" -- September 17, 2002 + DESCRIPTION + "Version 1.3 (draft 2) + + Adds support for multiple sFlow samplers per sFlowDataSource. + Moved to sflow.org enterprise number. + Splits flow sampling, counter polling and receiver + specification into separate tables." + + REVISION "200107310000Z" -- July 31, 2001 + DESCRIPTION + "Version 1.2 + + Brings MIB into SMI v2 compliance." + + REVISION "200105010000Z" -- May 1, 2001 + DESCRIPTION + "Version 1.1 + + Adds sfDatagramVersion." + + ::= { enterprises sflow(14706) 1 } + + sFlowAgent OBJECT IDENTIFIER ::= { sFlowMIB 1 } + + SFlowDataSource ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "Identifies a source of sFlow data. + + The following data source types are currently defined: + + - ifIndex.<I> + SFlowDataSources of this traditional form are called + 'port-based'. Ideally the sampling entity will perform + + - smonVlanDataSource.<V> + An SFlowDataSource of this form refers to a 'Packet-based VLAN' + and is called a 'VLAN-based' dataSource. <V> is the VLAN + ID as defined by the IEEE 802.1Q standard. The + value is between 1 and 4094 inclusive, and it represents + an 802.1Q VLAN-ID with global scope within a given + bridged domain. + + Note: Since each SFlowDataSource operates independently a + packet that crosses multiple DataSources may generate + multiple flow records." + SYNTAX OBJECT IDENTIFIER + + SFlowInstance ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "If more than one sFlow sampler is available for this + SFlowDataSource then individual samplers are distinguished + using the SFlowInstance variable. The value of + SFlowInstance ranges from 1..n where n is the number of + samplers associated with this SFlowDataSource. + + Note: Each sFlow sampler instance must operate + independently of all other instances. Setting + an attribute of one sampler must not alter the + the behavior and settings of other sampler + instances." + SYNTAX Integer32 (1..65535) + + SFlowReceiver ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "Identify the sFlow receiver associated with this resource. + + A value of zero indicates that this resource is available. + If non-zero the value must correspond to a valid, active + sFlowRcvrIndex. + + If the value is currently zero it may be set to any + active entry in the sFlowRcvrTable. If the value is + not zero then a set to anything other than zero or + its current value will result in an SNMP error (bad value)." + SYNTAX Integer32 + + sFlowVersion OBJECT-TYPE + SYNTAX SnmpAdminString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Uniquely identifies the version and implementation of this MIB. + The version string must have the following structure: + <MIB Version>;<Organization>;<Software Revision> + where: + <MIB Version> must be '1.3', the version of this MIB. + <Organization> the name of the organization responsible + for the agent implementation. + <Revision> the specific software build of this agent. + + + The MIB Version will change with each revision of the SFLOW + MIB. + + Management entities must check the MIB Version and not attempt + to manage agents with MIB Versions greater than that for which + they were designed. + + Note: The sFlow Datagram Format has an independent version + number which may change independently from <MIB Version>. + <MIB Version> applies to the structure and semantics of + the SFLOW MIB only." + DEFVAL { "1.3;;" } + ::= { sFlowAgent 1 } + + sFlowAgentAddressType OBJECT-TYPE + SYNTAX InetAddressType + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The address type of the address associated with this agent. + Only ipv4 and ipv6 types are supported." + ::= { sFlowAgent 2 } + + sFlowAgentAddress OBJECT-TYPE + SYNTAX InetAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The IP address associated with this agent. In the case of a + multi-homed agent, this should be the loopback address of the + agent. The sFlowAgent address must provide SNMP connectivity + to the agent. The address should be an invariant that does not + change as interfaces are reconfigured, enabled, disabled, + added or removed. A manager should be able to use the + sFlowAgentAddress as a unique key that will identify this + agent over extended periods of time so that a history can + be maintained." + ::= { sFlowAgent 3 } + + -- + -- Receiver Table + -- + + sFlowRcvrTable OBJECT-TYPE + SYNTAX SEQUENCE OF SFlowRcvrEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table of the receivers of sFlow information." + ::= { sFlowAgent 4 } + + sFlowRcvrEntry OBJECT-TYPE + SYNTAX SFlowRcvrEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Attributes of an sFlow Receiver." + INDEX { sFlowRcvrIndex } + ::= { sFlowRcvrTable 1 } + + SFlowRcvrEntry ::= SEQUENCE { + sFlowRcvrIndex Integer32, + sFlowRcvrOwner OwnerString, + sFlowRcvrTimeout Integer32, + sFlowRcvrMaximumDatagramSize Integer32, + sFlowRcvrAddressType InetAddressType, + sFlowRcvrAddress InetAddress, + sFlowRcvrPort Integer32, + sFlowRcvrDatagramVersion Integer32 + } + + sFlowRcvrIndex OBJECT-TYPE + SYNTAX Integer32 (1..65535) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Index into sFlowReceiverTable." + ::= { sFlowRcvrEntry 1 } + + sFlowRcvrOwner OBJECT-TYPE + SYNTAX OwnerString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The entity making use of this sFlowRcvrTable entry. The empty + string indicates that the entry is currently unclaimed. + An entity wishing to claim an sFlowRcvrTable entry must ensure + that the entry is unclaimed before trying to claim it. + The entry is claimed by setting the owner string. The entry + must be claimed before any changes can be made to other sampler + objects. + + In order to avoid a race condition, the entity taking control + of the sampler must set both the owner and a value for + sFlowRcvrTimeout in the same SNMP set request. + + When a management entity is finished using the sampler, + it should set the value of sFlowRcvrOwner back to unclaimed. + The agent must restore all other entities this row to their + default values when the owner is set to unclaimed. It must + also free all other resources associated with this + sFlowRcvrTable entry. + + This mechanism provides no enforcement and relies on the + cooperation of management entities in order to ensure that + competition for a receiver entry is fairly resolved." + DEFVAL { "" } + ::= { sFlowRcvrEntry 2 } + + sFlowRcvrTimeout OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The time (in seconds) remaining before the sampler is released + and stops sampling. When set, the owner establishes control + for the specified period. When read, the remaining time in the + interval is returned. + + A management entity wanting to maintain control of the sampler + is responsible for setting a new value before the old one + expires. + + When the interval expires, the agent is responsible for + restoring all other entities in this row to their default + values. It must also free all other resources associated with + this sFlowRcvrTable entry." + DEFVAL { 0 } + ::= { sFlowRcvrEntry 3 } + + sFlowRcvrMaximumDatagramSize OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The maximum number of data bytes that can be sent in a single + sample datagram. The manager should set this value to avoid + fragmentation of the sFlow datagrams." + DEFVAL { 1400 } + ::= { sFlowRcvrEntry 4 } + + sFlowRcvrAddressType OBJECT-TYPE + SYNTAX InetAddressType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The type of sFlowRcvrCollectorAddress." + DEFVAL { ipv4 } + ::= { sFlowRcvrEntry 5 } + + sFlowRcvrAddress OBJECT-TYPE + SYNTAX InetAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The IP address of the sFlow collector. + If set to 0.0.0.0 not sFlow datagrams will be sent." + DEFVAL { '00000000'h } -- 0.0.0.0 + ::= { sFlowRcvrEntry 6 } + + sFlowRcvrPort OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The destination port for sFlow datagrams." + DEFVAL { 6343 } + ::= { sFlowRcvrEntry 7 } + + sFlowRcvrDatagramVersion OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The version of sFlow datagrams that should be sent. + + When set to a value not support by the agent, the agent should + adjust the value to the highest supported value less than the + requested value, or return an SNMP bad value error if no + such value exists." + DEFVAL { 5 } + ::= { sFlowRcvrEntry 8 } + + -- + -- Flow Sampling Table + -- + + sFlowFsTable OBJECT-TYPE + SYNTAX SEQUENCE OF SFlowFsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table of the flow samplers within a device." + ::= { sFlowAgent 5 } + + sFlowFsEntry OBJECT-TYPE + SYNTAX SFlowFsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Attributes of a flow sampler." + INDEX { sFlowFsDataSource, sFlowFsInstance } + ::= { sFlowFsTable 1 } + + SFlowFsEntry ::= SEQUENCE { + sFlowFsDataSource SFlowDataSource, + sFlowFsInstance SFlowInstance, + sFlowFsReceiver SFlowReceiver, + sFlowFsPacketSamplingRate Integer32, + sFlowFsMaximumHeaderSize Integer32 + } + + sFlowFsDataSource OBJECT-TYPE + SYNTAX SFlowDataSource + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "sFlowDataSource for this flow sampler." + ::= { sFlowFsEntry 1 } + + sFlowFsInstance OBJECT-TYPE + SYNTAX SFlowInstance + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The sFlow instance for this flow sampler." + ::= { sFlowFsEntry 2 } + + sFlowFsReceiver OBJECT-TYPE + SYNTAX SFlowReceiver + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The SFlowReceiver for this flow sampler." + DEFVAL { 0 } + ::= { sFlowFsEntry 3 } + + sFlowFsPacketSamplingRate OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The statistical sampling rate for packet sampling from this + source. + + Set to N to sample 1/Nth of the packets in the monitored flows. + An agent should choose its own algorithm to introduce variance + into the sampling so that exactly every Nth packet is not + counted. A sampling rate of 1 counts all packets. A sampling + rate of 0 disables sampling. + + The agent is permitted to have minimum and maximum allowable + values for the sampling rate. A minimum rate lets the agent + designer set an upper bound on the overhead associated with + sampling, and a maximum rate may be the result of hardware + restrictions (such as counter size). In addition not all values + between the maximum and minimum may be realizable as the + sampling rate (again because of implementation considerations). + + When the sampling rate is set the agent is free to adjust the + value so that it lies between the maximum and minimum values + and has the closest achievable value. + + When read, the agent must return the actual sampling rate it + will be using (after the adjustments previously described). The + sampling algorithm must converge so that over time the number + of packets sampled approaches 1/Nth of the total number of + packets in the monitored flows." + DEFVAL { 0 } + ::= { sFlowFsEntry 4 } + + sFlowFsMaximumHeaderSize OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The maximum number of bytes that should be copied from a + sampled packet. The agent may have an internal maximum and + minimum permissible sizes. If an attempt is made to set this + value outside the permissible range then the agent should + adjust the value to the closest permissible value." + DEFVAL { 128 } + ::= { sFlowFsEntry 5 } + + -- + -- Counter Polling Table + -- + + + sFlowCpTable OBJECT-TYPE + SYNTAX SEQUENCE OF SFlowCpEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table of the counter pollers within a device." + ::= { sFlowAgent 6 } + + sFlowCpEntry OBJECT-TYPE + SYNTAX SFlowCpEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Attributes of a counter poller." + INDEX { sFlowCpDataSource, sFlowCpInstance } + ::= { sFlowCpTable 1 } + + SFlowCpEntry ::= SEQUENCE { + sFlowCpDataSource SFlowDataSource, + sFlowCpInstance SFlowInstance, + sFlowCpReceiver SFlowReceiver, + sFlowCpInterval Integer32 + } + + sFlowCpDataSource OBJECT-TYPE + SYNTAX SFlowDataSource + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Identifies the source of the data for the counter poller." + ::= { sFlowCpEntry 1 } + + sFlowCpInstance OBJECT-TYPE + SYNTAX SFlowInstance + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The sFlowInstance for this counter poller." + ::= { sFlowCpEntry 2 } + + sFlowCpReceiver OBJECT-TYPE + SYNTAX SFlowReceiver + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The SFlowReciever associated with this counter poller." + DEFVAL { 0 } + ::= { sFlowCpEntry 3 } + + sFlowCpInterval OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The maximum number of seconds between successive samples of the + counters associated with this data source. A sampling interval + of 0 disables counter sampling." + DEFVAL { 0 } + ::= { sFlowCpEntry 4 } + + + sFlowMIBConformance OBJECT IDENTIFIER ::= { sFlowMIB 2 } + sFlowMIBGroups OBJECT IDENTIFIER ::= { sFlowMIBConformance 1 } + sFlowMIBCompliances OBJECT IDENTIFIER ::= { sFlowMIBConformance 2 } + + sFlowCompliance MODULE-COMPLIANCE + STATUS current + DESCRIPTION + "Compliance statements for the sFlow Agent." + + MODULE -- this module + MANDATORY-GROUPS { sFlowAgentGroup } + + OBJECT sFlowAgentAddressType + SYNTAX InetAddressType + DESCRIPTION + "Agents need only support ipv4." + + OBJECT sFlowRcvrAddressType + SYNTAX InetAddressType + DESCRIPTION + "Agents need only support ipv4." + + ::= { sFlowMIBCompliances 1 } + + sFlowAgentGroup OBJECT-GROUP + OBJECTS { sFlowVersion, sFlowAgentAddressType, sFlowAgentAddress, + sFlowRcvrOwner, sFlowRcvrTimeout, + sFlowRcvrMaximumDatagramSize, sFlowRcvrAddressType, + sFlowRcvrAddress, sFlowRcvrPort, + sFlowRcvrDatagramVersion, sFlowFsReceiver, + sFlowFsPacketSamplingRate, sFlowFsMaximumHeaderSize, + sFlowCpReceiver, sFlowCpInterval } + STATUS current + DESCRIPTION + "A collection of objects for managing the generation and + transportation of sFlow data records." + ::= { sFlowMIBGroups 1 } + +END |