diff options
| author | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
|---|---|---|
| committer | David Leutgeb <david.leutgeb@mannundmouse.com> | 2023-12-05 12:25:34 +0100 |
| commit | 98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch) | |
| tree | 9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/quanta/dot3ad.my | |
| download | mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.tar.gz mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.zip | |
Diffstat (limited to 'MIBS/quanta/dot3ad.my')
| -rw-r--r-- | MIBS/quanta/dot3ad.my | 1302 |
1 files changed, 1302 insertions, 0 deletions
diff --git a/MIBS/quanta/dot3ad.my b/MIBS/quanta/dot3ad.my new file mode 100644 index 0000000..96f419c --- /dev/null +++ b/MIBS/quanta/dot3ad.my @@ -0,0 +1,1302 @@ +LAG-MIB DEFINITIONS ::= BEGIN + +-- ------------------------------------------------------------- +-- IEEE 802.3ad MIB +-- ------------------------------------------------------------- + +IMPORTS + MODULE-IDENTITY, OBJECT-TYPE, Counter32, TimeTicks, BITS + FROM SNMPv2-SMI + DisplayString, MacAddress, TEXTUAL-CONVENTION, TruthValue + FROM SNMPv2-TC + MODULE-COMPLIANCE, OBJECT-GROUP + FROM SNMPv2-CONF + InterfaceIndex + FROM IF-MIB + ; + + +lagMIB MODULE-IDENTITY + LAST-UPDATED "9911220000Z" + ORGANIZATION "Netgear Inc" + CONTACT-INFO "" + DESCRIPTION + "The Link Aggregation module for managing IEEE 802.3ad." + ::= { iso(1) member-body(2) us(840) dot3(10006) snmpmibs(300) linkagg(43) } + + +lagMIBObjects OBJECT IDENTIFIER ::= { lagMIB 1 } + + +-- ------------------------------------------------------------- +-- Textual Conventions +-- ------------------------------------------------------------- + + LacpKey ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "The Actor or Partner Key value." + SYNTAX INTEGER (0..65535) + + LacpState ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "The Actor and Partner State values from the LACPDU." + SYNTAX BITS { + lacpActivity(0), + lacpTimeout(1), + aggregation(2), + synchronization(3), + collecting(4), + distributing(5), + defaulted(6), + expired(7) + } + + ChurnState ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "The state of the Churn Detection machine." + SYNTAX INTEGER { + noChurn(1), + churn(2), + churnMonitor(3) + } + +PortList ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "Each octet within this value specifies a set of eight + ports, with the first octet specifying ports 1 through + 8, the second octet specifying ports 9 through 16, etc. + Within each octet, the most significant bit represents + the lowest numbered port, and the least significant bit + represents the highest numbered port. Thus, each port + of the bridge is represented by a single bit within the + value of this object. If that bit has a value of '1' + then that port is included in the set of ports; the port + is not included if its bit has a value of '0'." + SYNTAX OCTET STRING (SIZE(0..255)) + + +-- ------------------------------------------------------------- + +-- ------------------------------------------------------------- +-- groups in the LAG MIB +-- ------------------------------------------------------------- + +dot3adAgg OBJECT IDENTIFIER ::= { lagMIBObjects 1 } +dot3adAggPort OBJECT IDENTIFIER ::= { lagMIBObjects 2 } + + +-- ------------------------------------------------------------- + +-- ------------------------------------------------------------- +-- The Tables Last Changed Object +-- ------------------------------------------------------------- + +dot3adTablesLastChanged OBJECT-TYPE + SYNTAX TimeTicks + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object indicates the time of the + most recent change to the dot3adAggTable, + dot3adAggPortListTable, or + dot3adAggPortTable." +::= { lagMIBObjects 3 } + + +-- ------------------------------------------------------------- +-- The Aggregator Configuration Table +-- ------------------------------------------------------------- + +dot3adAggTable OBJECT-TYPE + SYNTAX SEQUENCE OF Dot3adAggEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table that contains information about every + Aggregator that is associated with this System." + REFERENCE + "IEEE 802.3 Subclause 30.7.1" +::= { dot3adAgg 1 } + +dot3adAggEntry OBJECT-TYPE + SYNTAX Dot3adAggEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of the Aggregator parameters. This is indexed + by the ifIndex of the Aggregator." + INDEX { dot3adAggIndex } +::= { dot3adAggTable 1 } + +Dot3adAggEntry ::= + SEQUENCE { + dot3adAggIndex + InterfaceIndex, + dot3adAggMACAddress + MacAddress, + dot3adAggActorSystemPriority + INTEGER, + dot3adAggActorSystemID + MacAddress, + dot3adAggAggregateOrIndividual + TruthValue, + dot3adAggActorAdminKey + LacpKey, + dot3adAggActorOperKey + LacpKey, + dot3adAggPartnerSystemID + MacAddress, + dot3adAggPartnerSystemPriority + INTEGER, + dot3adAggPartnerOperKey + LacpKey, + dot3adAggCollectorMaxDelay + INTEGER + } + +dot3adAggIndex OBJECT-TYPE + SYNTAX InterfaceIndex + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The unique identifier allocated to this Aggregator by the local System. + This attribute identifies an Aggregator instance among the subordinate + managed objects of the containing object. This value is read-only." + REFERENCE + "IEEE 802.3 Subclause 30.7.1.1.1" +::= { dot3adAggEntry 1 } + +dot3adAggMACAddress OBJECT-TYPE + SYNTAX MacAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A 6-octet read-only value carrying the individual + MAC address assigned to the Aggregator." + REFERENCE + "IEEE 802.3 Subclause 30.7.1.1.9" +::= { dot3adAggEntry 2 } + +dot3adAggActorSystemPriority OBJECT-TYPE + SYNTAX INTEGER (0..65535) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "A 2-octet read-write value indicating the priority value + associated with the Actor's System ID." + REFERENCE + "IEEE 802.3 Subclause 30.7.1.1.5" +::= { dot3adAggEntry 3 } + +dot3adAggActorSystemID OBJECT-TYPE + SYNTAX MacAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A 6-octet read-write MAC address value used as a unique + identifier for the System that contains this Aggregator. + NOTE -- From the perspective of the Link Aggregation mechanisms described + in Clause 43, only a single combination of Actor's System ID and System + Priority are considered, and no distinction is made between the values of + these parameters for an Aggregator and the port(s) that are associated + with it; i.e., the protocol is described in terms of the operation of + aggregation within a single System. However, the managed objects provided + for the Aggregator and the port both allow management of these parameters. + The result of this is to permit a single piece of equipment to be + configured by management to contain more than one System from the point of + view of the operation of Link Aggregation. This may be of particular use + in the configuration of equipment that has limited aggregation capability + (see 43.6)." + REFERENCE + "IEEE 802.3 Subclause 30.7.1.1.4" +::= { dot3adAggEntry 4 } + +dot3adAggAggregateOrIndividual OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A read-only Boolean value indicating whether the + Aggregator represents an Aggregate ('TRUE ') or + an Individual link ('FALSE ')." + REFERENCE + "IEEE 802.3 Subclause 30.7.1.1.6" +::= { dot3adAggEntry 5 } + +dot3adAggActorAdminKey OBJECT-TYPE + SYNTAX LacpKey + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The current administrative value of the Key for the Aggregator. + The administrative Key value may differ from the operational + Key value for the reasons discussed in 43.6.2. This is a 16-bit, + read-write value. The meaning of particular Key values + is of local significance." + REFERENCE + "IEEE 802.3 Subclause 30.7.1.1.7" +::= { dot3adAggEntry 6 } + +dot3adAggActorOperKey OBJECT-TYPE + SYNTAX LacpKey + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current operational value of the Key for the Aggregator. + The administrative Key value may differ from the operational + Key value for the reasons discussed in 43.6.2. + This is a 16-bit read-only value. The meaning of particular Key + values is of local significance." + REFERENCE + "IEEE 802.3 Subclause 30.7.1.1.8" +::= { dot3adAggEntry 7 } + +dot3adAggPartnerSystemID OBJECT-TYPE + SYNTAX MacAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A 6-octet read-only MAC address value consisting + of the unique identifier for the current protocol Partner of + this Aggregator. A value of zero indicates that there is no + known Partner. If the aggregation is manually configured, this + System ID value will be a value assigned by the local System." + REFERENCE + "IEEE 802.3 Subclause 30.7.1.1.10" +::= { dot3adAggEntry 8 } + +dot3adAggPartnerSystemPriority OBJECT-TYPE + SYNTAX INTEGER (0..65535) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A 2-octet read-only value that indicates the priority + value associated with the Partner's System ID. If the + aggregation is manually configured, this System Priority value + will be a value assigned by the local System." + REFERENCE + "IEEE 802.3 Subclause 30.7.1.1.11" +::= { dot3adAggEntry 9 } + +dot3adAggPartnerOperKey OBJECT-TYPE + SYNTAX LacpKey + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current operational value of the Key for the + Aggregator's current protocol Partner. This is + a 16-bit read-only value. If the aggregation is manually + configured, this Key value will be a value assigned by the + local System." + REFERENCE + "IEEE 802.3 Subclause 30.7.1.1.12" +::= { dot3adAggEntry 10 } + +dot3adAggCollectorMaxDelay OBJECT-TYPE + SYNTAX INTEGER (0..65535) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The value of this 16-bit read-write attribute defines + the maximum delay, in tens of microseconds, that + may be imposed by the Frame Collector between + receiving a frame from an Aggregator Parser, and + either delivering the frame to its MAC Client or discarding + the frame (see 43.2.3.1.1)." + REFERENCE + "IEEE 802.3 Subclause 30.7.1.1.32" +::= { dot3adAggEntry 11 } + + +-- ------------------------------------------------------------- +-- The Aggregation Port List Table +-- ------------------------------------------------------------- + +dot3adAggPortListTable OBJECT-TYPE + SYNTAX SEQUENCE OF Dot3adAggPortListEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table that contains a list of all the ports + associated with each Aggregator." + REFERENCE + "IEEE 802.3 Subclause 30.7.1.1.30" +::= { dot3adAgg 2 } + +dot3adAggPortListEntry OBJECT-TYPE + SYNTAX Dot3adAggPortListEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of the ports associated with a given Aggregator. + This is indexed by the ifIndex of the Aggregator." + INDEX { dot3adAggIndex } +::= { dot3adAggPortListTable 1 } + +Dot3adAggPortListEntry ::= + SEQUENCE { + dot3adAggPortListPorts + PortList + } + +dot3adAggPortListPorts OBJECT-TYPE + SYNTAX PortList + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The complete set of ports currently associated with + this Aggregator. Each bit set in this list represents + an Actor Port member of this Link Aggregation." + REFERENCE + "IEEE 802.3 Subclause 30.7.1.1.30" +::= { dot3adAggPortListEntry 1 } + + +-- ------------------------------------------------------------- +-- The Aggregation Port Table +-- ------------------------------------------------------------- + +dot3adAggPortTable OBJECT-TYPE + SYNTAX SEQUENCE OF Dot3adAggPortEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table that contains Link Aggregation Control + configuration information about every + Aggregation Port associated with this device. + A row appears in this table for each physical port." + REFERENCE + "IEEE 802.3 Subclause 30.7.2" +::= { dot3adAggPort 1 } + +dot3adAggPortEntry OBJECT-TYPE + SYNTAX Dot3adAggPortEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of Link Aggregation Control configuration + parameters for each Aggregation Port on this device." + INDEX { dot3adAggPortIndex } +::= { dot3adAggPortTable 1 } + +Dot3adAggPortEntry ::= + SEQUENCE { + dot3adAggPortIndex + InterfaceIndex, + dot3adAggPortActorSystemPriority + INTEGER, + dot3adAggPortActorSystemID + MacAddress, + dot3adAggPortActorAdminKey + LacpKey, + dot3adAggPortActorOperKey + LacpKey, + dot3adAggPortPartnerAdminSystemPriority + INTEGER, + dot3adAggPortPartnerOperSystemPriority + INTEGER, + dot3adAggPortPartnerAdminSystemID + MacAddress, + dot3adAggPortPartnerOperSystemID + MacAddress, + dot3adAggPortPartnerAdminKey + LacpKey, + dot3adAggPortPartnerOperKey + LacpKey, + dot3adAggPortSelectedAggID + InterfaceIndex, + dot3adAggPortAttachedAggID + InterfaceIndex, + dot3adAggPortActorPort + INTEGER, + dot3adAggPortActorPortPriority + INTEGER, + dot3adAggPortPartnerAdminPort + INTEGER, + dot3adAggPortPartnerOperPort + INTEGER, + dot3adAggPortPartnerAdminPortPriority + INTEGER, + dot3adAggPortPartnerOperPortPriority + INTEGER, + dot3adAggPortActorAdminState + LacpState, + dot3adAggPortActorOperState + LacpState, + dot3adAggPortPartnerAdminState + LacpState, + dot3adAggPortPartnerOperState + LacpState, + dot3adAggPortAggregateOrIndividual + TruthValue +} + +dot3adAggPortIndex OBJECT-TYPE + SYNTAX InterfaceIndex + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The ifIndex of the port" + REFERENCE + "IEEE 802.3 Subclause 30.7.2.1.1" +::= { dot3adAggPortEntry 1 } + +dot3adAggPortActorSystemPriority OBJECT-TYPE + SYNTAX INTEGER (0..65535) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "A 2-octet read-write value used to define the priority + value associated with the Actor's System ID." + REFERENCE + "IEEE 802.3 Subclause 30.7.2.1.2" +::= { dot3adAggPortEntry 2 } + +dot3adAggPortActorSystemID OBJECT-TYPE + SYNTAX MacAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A 6-octet read-only MAC address value that defines + the value of the System ID for the System that contains this + Aggregation Port." + REFERENCE + "IEEE 802.3 Subclause 30.7.2.1.3" +::= { dot3adAggPortEntry 3 } + +dot3adAggPortActorAdminKey OBJECT-TYPE + SYNTAX LacpKey + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The current administrative value of the Key for the + Aggregation Port. This is a 16-bit read-write value. + The meaning of particular Key values is of local significance." + REFERENCE + "IEEE 802.3 Subclause 30.7.2.1.4" +::= { dot3adAggPortEntry 4 } + +dot3adAggPortActorOperKey OBJECT-TYPE + SYNTAX LacpKey + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The current operational value of the Key for the + Aggregation Port. This is a 16-bit read-only value. + The meaning of particular Key values is of local significance." + REFERENCE + "IEEE 802.3 Subclause 30.7.2.1.5" +::= { dot3adAggPortEntry 5 } + +dot3adAggPortPartnerAdminSystemPriority OBJECT-TYPE + SYNTAX INTEGER (0..65535) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "A 2-octet read-write value used to define the administrative + value of priority associated with the Partner's System ID. The + assigned value is used, along with the value of + aAggPortPartnerAdminSystemID, aAggPortPartnerAdminKey, + aAggPortPartnerAdminPort, and aAggPortPartnerAdminPortPriority, + in order to achieve manually configured aggregation." + REFERENCE + "IEEE 802.3 Subclause 30.7.2.1.7" +::= { dot3adAggPortEntry 6 } + +dot3adAggPortPartnerOperSystemPriority OBJECT-TYPE + SYNTAX INTEGER (0..65535) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A 2-octet read-only value indicating the operational value + of priority associated with the Partner's System ID. The + value of this attribute may contain the manually configured value + carried in aAggPortPartnerAdminSystemPriority + if there is no protocol Partner." + REFERENCE + "IEEE 802.3 Subclause 30.7.2.1.7" +::= { dot3adAggPortEntry 7 } + +dot3adAggPortPartnerAdminSystemID OBJECT-TYPE + SYNTAX MacAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "A 6-octet read-write MACAddress value representing + the administrative value of the Aggregation Port's protocol + Partner's System ID. The assigned value is used, along with + the value of aAggPortPartnerAdminSystemPriority, + aAggPortPartnerAdminKey, aAggPortPartnerAdminPort, + and aAggPortPartnerAdminPortPriority, in order to + achieve manually configured aggregation." + REFERENCE + "IEEE 802.3 Subclause 30.7.2.1.8" +::= { dot3adAggPortEntry 8 } + +dot3adAggPortPartnerOperSystemID OBJECT-TYPE + SYNTAX MacAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A 6-octet read-only MACAddress value representing + the current value of the Aggregation Port's protocol Partner's + System ID. A value of zero indicates that there is no known + protocol Partner. The value of this attribute may contain the + manually configured value carried in + aAggPortPartnerAdminSystemID if there is no protocol Partner." + REFERENCE + "IEEE 802.3 Subclause 30.7.2.1.9" +::= { dot3adAggPortEntry 9 } + +dot3adAggPortPartnerAdminKey OBJECT-TYPE + SYNTAX LacpKey + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The current administrative value of the Key for the + protocol Partner. This is a 16-bit read-write value. + The assigned value is used, along with the value of + aAggPortPartnerAdminSystemPriority, aAggPortPartnerAdminSystemID, + aAggPortPartnerAdminPort, and aAggPortPartnerAdminPortPriority, + in order to achieve manually configured aggregation." + REFERENCE + "IEEE 802.3 Subclause 30.7.2.1.10" +::= { dot3adAggPortEntry 10 } + +dot3adAggPortPartnerOperKey OBJECT-TYPE + SYNTAX LacpKey + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current operational value of the Key for the + protocol Partner. The value of this attribute may contain + the manually configured value carried in + aAggPortPartnerAdminKey if there is no protocol Partner. + This is a 16-bit read-only value." + REFERENCE + "IEEE 802.3 Subclause 30.7.2.1.11" +::= { dot3adAggPortEntry 11 } + +dot3adAggPortSelectedAggID OBJECT-TYPE + SYNTAX InterfaceIndex + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The identifier value of the Aggregator that this Aggregation + Port has currently selected. Zero indicates that the Aggregation + Port has not selected an Aggregator, either because it is in the + process of detaching from an Aggregator or because there is no + suitable Aggregator available for it to select. This value is read-only." + REFERENCE + "IEEE 802.3 Subclause 30.7.2.1.12" +::= { dot3adAggPortEntry 12 } + +dot3adAggPortAttachedAggID OBJECT-TYPE + SYNTAX InterfaceIndex + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The identifier value of the Aggregator that this Aggregation + Port is currently attached to. Zero indicates that the Aggregation + Port is not currently attached to an Aggregator. This value is read-only." + REFERENCE + "IEEE 802.3 Subclause 30.7.2.1.13" +::= { dot3adAggPortEntry 13 } + +dot3adAggPortActorPort OBJECT-TYPE + SYNTAX INTEGER (0..65535) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The port number locally assigned to the Aggregation Port. + The port number is communicated in LACPDUs as the + Actor_Port. This value is read-only." + REFERENCE + "IEEE 802.3 Subclause 30.7.2.1.14" +::= { dot3adAggPortEntry 14 } + +dot3adAggPortActorPortPriority OBJECT-TYPE + SYNTAX INTEGER (0..65535) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The priority value assigned to this Aggregation Port. + This 16-bit value is read-write." + REFERENCE + "IEEE 802.3 Subclause 30.7.2.1.15" +::= { dot3adAggPortEntry 15 } + +dot3adAggPortPartnerAdminPort OBJECT-TYPE + SYNTAX INTEGER (0..65535) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The current administrative value of the port number + for the protocol Partner. This is a 16-bit read-write value. + The assigned value is used, along with the value of + aAggPortPartnerAdminSystemPriority, + aAggPortPartnerAdminSystemID, aAggPortPartnerAdminKey, + and aAggPortPartnerAdminPortPriority, + in order to achieve manually configured aggregation." + REFERENCE + "IEEE 802.3 Subclause 30.7.2.1.16" +::= { dot3adAggPortEntry 16 } + +dot3adAggPortPartnerOperPort OBJECT-TYPE + SYNTAX INTEGER (0..65535) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The operational port number assigned to this Aggregation + Port by the Aggregation Port's protocol Partner. The value + of this attribute may contain the manually configured value + carried in aAggPortPartnerAdminPort if there is no protocol + Partner. This 16-bit value is read-only." + REFERENCE + "IEEE 802.3 Subclause 30.7.2.1.17" +::= { dot3adAggPortEntry 17 } + +dot3adAggPortPartnerAdminPortPriority OBJECT-TYPE + SYNTAX INTEGER (0..65535) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The current administrative value of the port priority + for the protocol Partner. This is a 16-bit read-write value. + The assigned value is used, along with the value of + aAggPortPartnerAdminSystemPriority, aAggPortPartnerAdminSystemID, + aAggPortPartnerAdminKey, and aAggPortPartnerAdminPort, + in order to achieve manually configured aggregation." + REFERENCE + "IEEE 802.3 Subclause 30.7.2.1.18" +::= { dot3adAggPortEntry 18 } + +dot3adAggPortPartnerOperPortPriority OBJECT-TYPE + SYNTAX INTEGER (0..65535) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The priority value assigned to this Aggregation Port + by the Partner. The value of this attribute may contain the + manually configured value carried in + aAggPortPartnerAdminPortPriority if there is no + protocol Partner. This 16-bit value is read-only." + REFERENCE + "IEEE 802.3 Subclause 30.7.2.1.19" +::= { dot3adAggPortEntry 19 } + +dot3adAggPortActorAdminState OBJECT-TYPE + SYNTAX LacpState + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "A string of 8 bits, corresponding to the administrative values + of Actor_State (43.4.2) as transmitted by the Actor in LACPDUs. + The first bit corresponds to bit 0 of Actor_State (LACP_Activity), + the second bit corresponds to bit 1 (LACP_Timeout), the third bit + corresponds to bit 2 (Aggregation), the fourth bit corresponds to + bit 3 (Synchronization), the fifth bit corresponds to bit 4 + (Collecting), the sixth bit corresponds to bit 5 (Distributing), + the seventh bit corresponds to bit 6 (Defaulted), and the eighth + bit corresponds to bit 7 (Expired). These values allow + administrative control over the values of LACP_Activity, + LACP_Timeout and Aggregation. This attribute value is read-write." + REFERENCE + "IEEE 802.3 Subclause 30.7.2.1.20" +::= { dot3adAggPortEntry 20 } + +dot3adAggPortActorOperState OBJECT-TYPE + SYNTAX LacpState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A string of 8 bits, corresponding to the current + operational values of Actor_State as transmitted by the + Actor in LACPDUs. The bit allocations are as defined in + 30.7.2.1.20. This attribute value is read-only." + REFERENCE + "IEEE 802.3 Subclause 30.7.2.1.21" +::= { dot3adAggPortEntry 21 } + +dot3adAggPortPartnerAdminState OBJECT-TYPE + SYNTAX LacpState + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "A string of 8 bits, corresponding to the current administrative + value of Actor_State for the protocol Partner. The bit + allocations are as defined in 30.7.2.1.20. This attribute value is + read-write. The assigned value is used in order to achieve + manually configured aggregation." + REFERENCE + "IEEE 802.3 Subclause 30.7.2.1.22" +::= { dot3adAggPortEntry 22 } + +dot3adAggPortPartnerOperState OBJECT-TYPE + SYNTAX LacpState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A string of 8 bits, corresponding to the current values of + Actor_State in the most recently received LACPDU transmitted + by the protocol Partner. The bit allocations are as defined in + 30.7.2.1.20. In the absence of an active protocol Partner, this + value may reflect the manually configured value + aAggPortPartnerAdminState. This attribute value is read-only." + REFERENCE + "IEEE 802.3 Subclause 30.7.2.1.23" +::= { dot3adAggPortEntry 23 } + +dot3adAggPortAggregateOrIndividual OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A read-only Boolean value indicating whether the + Aggregation Port is able to Aggregate ('TRUE ') or is + only able to operate as an Individual link ('FALSE ')." + REFERENCE + "IEEE 802.3 Subclause 30.7.1.1.24" +::= { dot3adAggPortEntry 24 } + + +-- ------------------------------------------------------------- +-- LACP Statistics Table +-- ------------------------------------------------------------- + +dot3adAggPortStatsTable OBJECT-TYPE + SYNTAX SEQUENCE OF Dot3adAggPortStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table that contains Link Aggregation information + about every port that is associated with this device. + A row appears in this table for each physical port." + REFERENCE + "IEEE 802.3 Subclause 30.7.3" +::= { dot3adAggPort 2 } + +dot3adAggPortStatsEntry OBJECT-TYPE + SYNTAX Dot3adAggPortStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of Link Aggregation Control Protocol statistics + for each port on this device." + INDEX { dot3adAggPortIndex } +::= { dot3adAggPortStatsTable 1 } + +Dot3adAggPortStatsEntry ::= + SEQUENCE { + dot3adAggPortStatsLACPDUsRx + Counter32, + dot3adAggPortStatsMarkerPDUsRx + Counter32, + dot3adAggPortStatsMarkerResponsePDUsRx + Counter32, + dot3adAggPortStatsUnknownRx + Counter32, + dot3adAggPortStatsIllegalRx + Counter32, + dot3adAggPortStatsLACPDUsTx + Counter32, + dot3adAggPortStatsMarkerPDUsTx + Counter32, + dot3adAggPortStatsMarkerResponsePDUsTx + Counter32 + } + +dot3adAggPortStatsLACPDUsRx OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of valid LACPDUs received on this + Aggregation Port. This value is read-only." + REFERENCE + "IEEE 802.3 Subclause 30.7.3.1.2" +::= { dot3adAggPortStatsEntry 1 } + +dot3adAggPortStatsMarkerPDUsRx OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of valid Marker PDUs received on this + Aggregation Port. This value is read-only." + REFERENCE + "IEEE 802.3 Subclause 30.7.3.1.3" +::= { dot3adAggPortStatsEntry 2 } + +dot3adAggPortStatsMarkerResponsePDUsRx OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of valid Marker Response PDUs received on this + Aggregation Port. This value is read-only." + REFERENCE + "IEEE 802.3 Subclause 30.7.3.1.4" +::= { dot3adAggPortStatsEntry 3 } + +dot3adAggPortStatsUnknownRx OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of frames recei ed that either: + - carry the Slow Protocols Ethernet Type value (43B.4), + but contain an unknown PDU, or: + - are addressed to the Slow Protocols group MAC + Address (43B.3), but do not carry the Slow Protocols Ethernet Type. + This value is read-only." + REFERENCE + "IEEE 802.3 Subclause 30.7.3.1.5" +::= { dot3adAggPortStatsEntry 4 } + +dot3adAggPortStatsIllegalRx OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of frames received that carry the Slow + Protocols Ethernet Type value (43B.4), but contain a badly formed + PDU or an illegal value of Protocol Subtype (43B.4). + This value is read-only." + REFERENCE + "IEEE 802.3 Subclause 30.7.3.1.6" +::= { dot3adAggPortStatsEntry 5 } + +dot3adAggPortStatsLACPDUsTx OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of LACPDUs transmitted on this + Aggregation Port. This value is read-only." + REFERENCE + "IEEE 802.3 Subclause 30.7.3.1.7" +::= { dot3adAggPortStatsEntry 6 } + +dot3adAggPortStatsMarkerPDUsTx OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Marker PDUs transmitted on this + Aggregation Port. This value is read-only." + REFERENCE + "IEEE 802.3 Subclause 30.7.3.1.8" +::= { dot3adAggPortStatsEntry 7 } + +dot3adAggPortStatsMarkerResponsePDUsTx OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Marker Response PDUs transmitted + on this Aggregation Port. This value is read-only." + REFERENCE + "IEEE 802.3 Subclause 30.7.3.1.9" +::= { dot3adAggPortStatsEntry 8 } + + +-- ------------------------------------------------------------- +-- LACP Debug Table +-- ------------------------------------------------------------- + +dot3adAggPortDebugTable OBJECT-TYPE + SYNTAX SEQUENCE OF Dot3adAggPortDebugEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table that contains Link Aggregation debug + information about every port that is associated with + this device. A row appears in this table for each + physical port." + REFERENCE + "IEEE 802.3 Subclause 30.7.4" +::= { dot3adAggPort 3 } + +dot3adAggPortDebugEntry OBJECT-TYPE + SYNTAX Dot3adAggPortDebugEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of the debug parameters for a port." + INDEX { dot3adAggPortIndex } +::= { dot3adAggPortDebugTable 1 } + +Dot3adAggPortDebugEntry ::= + SEQUENCE { + dot3adAggPortDebugRxState + INTEGER, + dot3adAggPortDebugLastRxTime + TimeTicks, + dot3adAggPortDebugMuxState + INTEGER, + dot3adAggPortDebugMuxReason + DisplayString, + dot3adAggPortDebugActorChurnState + ChurnState, + dot3adAggPortDebugPartnerChurnState + ChurnState, + dot3adAggPortDebugActorChurnCount + Counter32, + dot3adAggPortDebugPartnerChurnCount + Counter32, + dot3adAggPortDebugActorSyncTransitionCount + Counter32, + dot3adAggPortDebugPartnerSyncTransitionCount + Counter32, + dot3adAggPortDebugActorChangeCount + Counter32, + dot3adAggPortDebugPartnerChangeCount + Counter32 + } + +dot3adAggPortDebugRxState OBJECT-TYPE + SYNTAX INTEGER { + current(1), + expired(2), + defaulted(3), + initialize(4), + lacpDisabled(5), + portDisabled(6) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This attribute holds the value 'current ' if the Receive + state machine for the Aggregation Port is in the + CURRENT state, 'expired' if the Receive state machine + is in the EXPIRED state, 'defaulted' if the Receive state + machine is in the DEFAULTED state, 'initialize' if the + Receive state machine is in the INITIALIZE state, + 'lacpDisabled' if the Receive state machine is in the + LACP_DISABLED state, or 'portDisabled' if the Receive + state machine is in the PORT_DISABLED state. + This value is read-only." + REFERENCE + "IEEE 802.3 Subclause 30.7.4.1.2" +::= { dot3adAggPortDebugEntry 1 } + +dot3adAggPortDebugLastRxTime OBJECT-TYPE + SYNTAX TimeTicks + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The value of aTimeSinceSystemReset (F.2.1) when + the last LACPDU was received by this Aggregation Port. + This value is read-only." + REFERENCE + "IEEE 802.3 Subclause 30.7.4.1.3" +::= { dot3adAggPortDebugEntry 2 } + +dot3adAggPortDebugMuxState OBJECT-TYPE + SYNTAX INTEGER { + detached(1), + waiting(2), + attached(3), + collecting(4), + distributing(5), + collecting-distributing(6) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This attribute holds the value 'detached' if the Mux + state machine (43.4.14) for the Aggregation Port is + in the DETACHED state, 'waiting' if the Mux state machine + is in the WAITING state, 'attached' if the Mux state + machine for the Aggregation Port is in the ATTACHED + state, 'collecting' if the Mux state machine for the + Aggregation Port is in the COLLECTING state, 'distributing' + if the Mux state machine for the Aggregation Port is + in the DISTRIBUTING state, and 'collecting-distributing' + if the Mux state machine for the Aggregation Port is in + the COLLECTING-DISTRIBUTING state. + This value is read-only." + REFERENCE + "IEEE 802.3 Subclause 30.7.4.1.4" +::= { dot3adAggPortDebugEntry 3 } + +dot3adAggPortDebugMuxReason OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A human-readable text string indicating the reason + for the most recent change of Mux machine state. + This value is read-only." + REFERENCE + "IEEE 802.3 Subclause 30.7.4.1.5" +::= { dot3adAggPortDebugEntry 4 } + +dot3adAggPortDebugActorChurnState OBJECT-TYPE + SYNTAX ChurnState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The state of the Actor Churn Detection machine + (43.4.17) for the Aggregation Port. A value of 'noChurn' + indicates that the state machine is in either the + NO_ACTOR_CHURN or the ACTOR_CHURN_MONITOR + state, and 'churn' indicates that the state machine is in the + ACTOR_CHURN state. This value is read-only." + REFERENCE + "IEEE 802.3 Subclause 30.7.4.1.6" +::= { dot3adAggPortDebugEntry 5 } + +dot3adAggPortDebugPartnerChurnState OBJECT-TYPE + SYNTAX ChurnState + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The state of the Partner Churn Detection machine + (43.4.17) for the Aggregation Port. A value of 'noChurn' + indicates that the state machine is in either the + NO_PARTNER_CHURN or the PARTNER_CHURN_MONITOR + state, and 'churn' indicates that the state machine is + in the PARTNER_CHURN state. + This value is read-only." + REFERENCE + "IEEE 802.3 Subclause 30.7.4.1.7" +::= { dot3adAggPortDebugEntry 6 } + +dot3adAggPortDebugActorChurnCount OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Count of the number of times the Actor Churn state + machine has entered the ACTOR_CHURN state. + This value is read-only." + REFERENCE + "IEEE 802.3 Subclause 30.7.4.1.8" +::= { dot3adAggPortDebugEntry 7 } + +dot3adAggPortDebugPartnerChurnCount OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Count of the number of times the Partner Churn + state machine has entered the PARTNER_CHURN state. + This value is read-only." + REFERENCE + "IEEE 802.3 Subclause 30.7.4.1.9" +::= { dot3adAggPortDebugEntry 8 } + +dot3adAggPortDebugActorSyncTransitionCount OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Count of the number of times the Actor's Mux state + machine (43.4.15) has entered the IN_SYNC state. + This value is read-only." + REFERENCE + "IEEE 802.3 Subclause 30.7.4.1.10" +::= { dot3adAggPortDebugEntry 9 } + +dot3adAggPortDebugPartnerSyncTransitionCount OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Count of the number of times the Partner's Mux + state machine (43.4.15) has entered the IN_SYNC state. + This value is read-only." + REFERENCE + "IEEE 802.3 Subclause 30.7.4.1.11" +::= { dot3adAggPortDebugEntry 10 } + +dot3adAggPortDebugActorChangeCount OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Count of the number of times the Actor's perception of + the LAG ID for this Aggregation Port has changed. + This value is read-only." + REFERENCE + "IEEE 802.3 Subclause 30.7.4.1.12" +::= { dot3adAggPortDebugEntry 11 } + +dot3adAggPortDebugPartnerChangeCount OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Count of the number of times the Partner's perception of + the LAG ID (see 43.3.6.1) for this Aggregation Port has changed. + This value is read-only." + REFERENCE + "IEEE 802.3 Subclause 30.7.4.1.13" +::= { dot3adAggPortDebugEntry 12 } + + +-- ------------------------------------------------------------- +-- IEEE 802.3ad MIB -Conformance Information +-- ------------------------------------------------------------- + +dot3adAggConformance OBJECT IDENTIFIER ::= {lagMIB 2 } + +dot3adAggGroups OBJECT IDENTIFIER ::= { dot3adAggConformance 1 } + +dot3adAggCompliances OBJECT IDENTIFIER +::= { dot3adAggConformance 2 } + + +-- ------------------------------------------------------------- +-- units of conformance +-- ------------------------------------------------------------- + +dot3adAggGroup OBJECT-GROUP + OBJECTS { + dot3adAggActorSystemID, + dot3adAggActorSystemPriority, + dot3adAggAggregateOrIndividual, + dot3adAggActorAdminKey, + dot3adAggMACAddress, + dot3adAggActorOperKey, + dot3adAggPartnerSystemID, + dot3adAggPartnerSystemPriority, + dot3adAggPartnerOperKey, + dot3adAggCollectorMaxDelay + } + STATUS current + DESCRIPTION + "A collection of objects providing information about an + aggregation." +::= { dot3adAggGroups 1 } + +dot3adAggPortListGroup OBJECT-GROUP + OBJECTS { + dot3adAggPortListPorts + } + STATUS current + DESCRIPTION + "A collection of objects providing information about every + port in an aggregation." +::= { dot3adAggGroups 2 } + +dot3adAggPortGroup OBJECT-GROUP + OBJECTS { + dot3adAggPortActorSystemPriority, + dot3adAggPortActorSystemID, + dot3adAggPortActorAdminKey, + dot3adAggPortActorOperKey, + dot3adAggPortPartnerAdminSystemPriority, + dot3adAggPortPartnerOperSystemPriority, + dot3adAggPortPartnerAdminSystemID, + dot3adAggPortPartnerOperSystemID, + dot3adAggPortPartnerAdminKey, + dot3adAggPortPartnerOperKey, + dot3adAggPortSelectedAggID, + dot3adAggPortAttachedAggID, + dot3adAggPortActorPort, + dot3adAggPortActorPortPriority, + dot3adAggPortPartnerAdminPort, + dot3adAggPortPartnerOperPort, + dot3adAggPortPartnerAdminPortPriority, + dot3adAggPortPartnerOperPortPriority, + dot3adAggPortActorAdminState, + dot3adAggPortActorOperState, + dot3adAggPortPartnerAdminState, + dot3adAggPortPartnerOperState, + dot3adAggPortAggregateOrIndividual + } + STATUS current + DESCRIPTION + "A collection of objects providing information about every + port in an aggregation." +::= { dot3adAggGroups 3 } + +dot3adAggPortStatsGroup OBJECT-GROUP + OBJECTS { + dot3adAggPortStatsLACPDUsRx, + dot3adAggPortStatsMarkerPDUsRx, + dot3adAggPortStatsMarkerResponsePDUsRx, + dot3adAggPortStatsUnknownRx, + dot3adAggPortStatsIllegalRx, + dot3adAggPortStatsLACPDUsTx, + dot3adAggPortStatsMarkerPDUsTx, + dot3adAggPortStatsMarkerResponsePDUsTx + } + STATUS current + DESCRIPTION + "A collection of objects providing information about every + port in an aggregation." +::= { dot3adAggGroups 4 } + +dot3adAggPortDebugGroup OBJECT-GROUP + OBJECTS { + dot3adAggPortDebugRxState, + dot3adAggPortDebugLastRxTime, + dot3adAggPortDebugMuxState, + dot3adAggPortDebugMuxReason, + dot3adAggPortDebugActorChurnState, + dot3adAggPortDebugPartnerChurnState, + dot3adAggPortDebugActorChurnCount, + dot3adAggPortDebugPartnerChurnCount, + dot3adAggPortDebugActorSyncTransitionCount, + dot3adAggPortDebugPartnerSyncTransitionCount, + dot3adAggPortDebugActorChangeCount, + dot3adAggPortDebugPartnerChangeCount + } + STATUS current + DESCRIPTION + "A collection of objects providing debug information about + every aggregated port." +::= { dot3adAggGroups 5 } + +dot3adTablesLastChangedGroup OBJECT-GROUP + OBJECTS { + dot3adTablesLastChanged + } + STATUS current + DESCRIPTION + "A collection of objects providing information about the time + of changes to the configuration of aggregations and their ports." +::= { dot3adAggGroup 6 } + + +-- ------------------------------------------------------------- +-- compliance statements +-- ------------------------------------------------------------- + +dot3adAggCompliance MODULE-COMPLIANCE + STATUS current + DESCRIPTION + "The compliance statement for device support of + Link Aggregation." + + MODULE + MANDATORY-GROUPS { + dot3adAggGroup, + dot3adAggPortGroup, + dot3adTablesLastChangedGroup + } + + GROUP dot3adAggPortListGroup + DESCRIPTION + "This group is optional." + + GROUP dot3adAggPortStatsGroup + DESCRIPTION + "This group is optional." + + GROUP dot3adAggPortDebugGroup + DESCRIPTION + "This group is optional." + +::= { dot3adAggCompliances 1 } + + +END |