summaryrefslogtreecommitdiff
path: root/MIBS/quanta/cheetahref.my
diff options
context:
space:
mode:
authorDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
committerDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
commit98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch)
tree9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/quanta/cheetahref.my
downloadmibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.tar.gz
mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.zip
Initial commitHEADmain
Diffstat (limited to 'MIBS/quanta/cheetahref.my')
-rw-r--r--MIBS/quanta/cheetahref.my306
1 files changed, 306 insertions, 0 deletions
diff --git a/MIBS/quanta/cheetahref.my b/MIBS/quanta/cheetahref.my
new file mode 100644
index 0000000..3208e4d
--- /dev/null
+++ b/MIBS/quanta/cheetahref.my
@@ -0,0 +1,306 @@
+QUANTA-LB6M-REF-MIB DEFINITIONS ::= BEGIN
+
+-- Netgear Fastpath Reference MIB
+-- Copyright Netgear Inc (2001-2007) All rights reserved.
+
+-- This SNMP Management Information Specification
+-- embodies Netgear Inc confidential and proprietary
+-- intellectual property. Netgear Inc retains all title
+-- and ownership in the Specification including any revisions.
+
+-- This Specification is supplied "AS IS", Netgear Inc
+-- makes no warranty, either expressed or implied,
+-- as to the use, operation, condition, or performance of the
+-- Specification.
+
+
+IMPORTS
+ MODULE-IDENTITY FROM SNMPv2-SMI
+ TEXTUAL-CONVENTION FROM SNMPv2-TC
+ enterprises FROM RFC1155-SMI;
+
+ broadcom MODULE-IDENTITY
+ LAST-UPDATED "200705230000Z" -- 23 May 2007 12:00:00 GMT
+ ORGANIZATION "Netgear Inc"
+ CONTACT-INFO ""
+ DESCRIPTION
+ ""
+
+ -- Revision history.
+ REVISION
+ "200705230000Z" -- 23 May 2007 12:00:00 GMT
+ DESCRIPTION
+ "Netgear branding related changes."
+ REVISION
+ "200311210000Z" -- 21 Nov 2003 12:00:00 GMT
+ DESCRIPTION
+ "Revisions made for new release."
+ REVISION
+ "200302061200Z" -- 6 February 2003 12:00:00 GMT
+ DESCRIPTION
+ "Updated for release"
+
+ ::= { enterprises 4413 }
+
+
+-- New definitions
+quantaProducts OBJECT IDENTIFIER ::= { broadcom 1 }
+lb6m OBJECT IDENTIFIER ::= { quantaProducts 1 }
+
+netgear OBJECT IDENTIFIER ::= { enterprises 4526 }
+
+--
+-- below are products that defined prior to NMS100 release that they have product code
+-- defined directly above the functions objects
+--
+managedSwitch OBJECT IDENTIFIER ::= { netgear 1 }
+vpnrouter OBJECT IDENTIFIER ::= { netgear 2 }
+carrier OBJECT IDENTIFIER ::= { netgear 3 }
+wireless OBJECT IDENTIFIER ::= { netgear 4 }
+rps OBJECT IDENTIFIER ::= { netgear 5 }
+wlanswitch OBJECT IDENTIFIER ::= { netgear 6 }
+
+---
+--- 700 series L2 managed switch
+---
+fsm726s OBJECT IDENTIFIER ::= { managedSwitch 1 }
+fsm750s OBJECT IDENTIFIER ::= { managedSwitch 2 }
+gsm712 OBJECT IDENTIFIER ::= { managedSwitch 3 }
+fsm726 OBJECT IDENTIFIER ::= { managedSwitch 4 }
+gsm712f OBJECT IDENTIFIER ::= { managedSwitch 5 }
+fsm726v2 OBJECT IDENTIFIER ::= { managedSwitch 10 }
+
+---
+--- AP
+---
+me103 OBJECT IDENTIFIER ::= { wireless 1 }
+wg302 OBJECT IDENTIFIER ::= { wireless 2 }
+wg102 OBJECT IDENTIFIER ::= { wireless 3 }
+wag302 OBJECT IDENTIFIER ::= { wireless 4 }
+wag102 OBJECT IDENTIFIER ::= { wireless 5 }
+---
+--- Added by Stephen Tsai 2-06-2006
+---
+wg302v2 OBJECT IDENTIFIER ::= { wireless 6 }
+wag302v2 OBJECT IDENTIFIER ::= { wireless 7 }
+
+
+
+---
+--- WLAN Switch
+---
+wls538 OBJECT IDENTIFIER ::= { wlanswitch 1 }
+
+---
+--- 7000 series L2/L3 managed switch
+---
+gsm7312 OBJECT IDENTIFIER ::= { managedSwitch 6 }
+gsm7324 OBJECT IDENTIFIER ::= { managedSwitch 7 }
+gsm7224 OBJECT IDENTIFIER ::= { managedSwitch 8 }
+fsm7326p OBJECT IDENTIFIER ::= { managedSwitch 9 }
+
+---********************************************************************
+--- new post-NMS100 SNMP products
+---
+
+--
+-- new post-NMS100 SNMP-enabled products. These products will have their
+-- functions defined under each generic product category.
+--
+lb6m OBJECT IDENTIFIER ::= { netgear 10 }
+ng700smartswitch OBJECT IDENTIFIER ::= { netgear 11 }
+ngrouter OBJECT IDENTIFIER ::= { netgear 12 }
+ngfirewall OBJECT IDENTIFIER ::= { netgear 13 }
+ngap OBJECT IDENTIFIER ::= { netgear 14 }
+ngwlan OBJECT IDENTIFIER ::= { netgear 15 }
+ng9000chassisswitch OBJECT IDENTIFIER ::= { netgear 16 }
+ng700stacksmartswitch OBJECT IDENTIFIER ::= { netgear 17 }
+
+--
+-- and their sysObjectID will be under a branch on their own
+--
+productID OBJECT IDENTIFIER ::= { netgear 100 }
+
+stackswitch OBJECT IDENTIFIER ::= { productID 1 }
+l2switch OBJECT IDENTIFIER ::= { productID 2 }
+l3switch OBJECT IDENTIFIER ::= { productID 3 }
+smartswitch OBJECT IDENTIFIER ::= { productID 4 }
+l2Rswitch OBJECT IDENTIFIER ::= { productID 11 }
+
+router OBJECT IDENTIFIER ::= { productID 5 }
+firewall OBJECT IDENTIFIER ::= { productID 6 }
+accesspoint OBJECT IDENTIFIER ::= { productID 7 }
+wirelessLAN OBJECT IDENTIFIER ::= { productID 8 }
+chassisswitch OBJECT IDENTIFIER ::= { productID 9 }
+stacksmartswitch OBJECT IDENTIFIER ::= { productID 10 }
+
+--
+-- Managed switches
+--
+fsm7328s OBJECT IDENTIFIER ::= { stackswitch 1 }
+fsm7352s OBJECT IDENTIFIER ::= { stackswitch 2 }
+gsm7328s OBJECT IDENTIFIER ::= { stackswitch 3 }
+gsm7352s OBJECT IDENTIFIER ::= { stackswitch 4 }
+fsm7352ps OBJECT IDENTIFIER ::= { stackswitch 5 }
+fsm7328ps OBJECT IDENTIFIER ::= { stackswitch 8 }
+gsm7328fs OBJECT IDENTIFIER ::= { stackswitch 7 }
+gsm7228ps OBJECT IDENTIFIER ::= { stackswitch 9 }
+gsm7252ps OBJECT IDENTIFIER ::= { stackswitch 10 }
+fsm7226rs OBJECT IDENTIFIER ::= { stackswitch 11 }
+fsm7250rs OBJECT IDENTIFIER ::= { stackswitch 12 }
+gsm7328se OBJECT IDENTIFIER ::= { stackswitch 13 }
+gsm7352se OBJECT IDENTIFIER ::= { stackswitch 14 }
+xsm7224s OBJECT IDENTIFIER ::= { stackswitch 15 }
+
+m530028gpoe OBJECT IDENTIFIER ::= { stackswitch 16 }
+m530052gpoe OBJECT IDENTIFIER ::= { stackswitch 17 }
+m530028g3 OBJECT IDENTIFIER ::= { stackswitch 18 }
+m530052g3 OBJECT IDENTIFIER ::= { stackswitch 19 }
+m530028gf3 OBJECT IDENTIFIER ::= { stackswitch 20 }
+m530028g OBJECT IDENTIFIER ::= { stackswitch 21 }
+m530052g OBJECT IDENTIFIER ::= { stackswitch 22 }
+
+gsm7312v2 OBJECT IDENTIFIER ::= { l3switch 1 }
+gsm7324v2 OBJECT IDENTIFIER ::= { l3switch 2 }
+xsm7312 OBJECT IDENTIFIER ::= { l3switch 3 }
+gsm7324p OBJECT IDENTIFIER ::= { l3switch 4 }
+
+gsm7224r OBJECT IDENTIFIER ::= { l2Rswitch 1 }
+gsm7248r OBJECT IDENTIFIER ::= { l2Rswitch 2 }
+gsm7224rp OBJECT IDENTIFIER ::= { l2Rswitch 3 }
+gsm7248rp OBJECT IDENTIFIER ::= { l2Rswitch 4 }
+gsm7224v2 OBJECT IDENTIFIER ::= { l2Rswitch 5 }
+gsm7248v2 OBJECT IDENTIFIER ::= { l2Rswitch 6 }
+
+gsm7212f OBJECT IDENTIFIER ::= { l2Rswitch 7 }
+gsm5212p OBJECT IDENTIFIER ::= { l2Rswitch 8 }
+gsm7212p OBJECT IDENTIFIER ::= { l2Rswitch 9 }
+gsm7224p OBJECT IDENTIFIER ::= { l2Rswitch 10 }
+
+m4100-26g OBJECT IDENTIFIER ::= { l2Rswitch 16 }
+m4100-50g OBJECT IDENTIFIER ::= { l2Rswitch 17 }
+m4100-26-poe OBJECT IDENTIFIER ::= { l2Rswitch 18 }
+m4100-26g-poe OBJECT IDENTIFIER ::= { l2Rswitch 19 }
+m4100-50g-poe OBJECT IDENTIFIER ::= { l2Rswitch 20 }
+m4100-50-poe OBJECT IDENTIFIER ::= { l2Rswitch 21 }
+m4100-d12g OBJECT IDENTIFIER ::= { l2Rswitch 22 }
+m4100-d10-poe OBJECT IDENTIFIER ::= { l2Rswitch 23 }
+m4100-12gf OBJECT IDENTIFIER ::= { l2Rswitch 24 }
+m4100-d12g-poe OBJECT IDENTIFIER ::= { l2Rswitch 25 }
+m4100-12g-poe OBJECT IDENTIFIER ::= { l2Rswitch 26 }
+m4100-24g-poe OBJECT IDENTIFIER ::= { l2Rswitch 27 }
+
+--
+-- GSM7324, GSM7312, FSM7326P, and GSM7224, are using two different styles
+-- of FP private MIB: dedicate and generic. For those using dedicated one, the sysOID
+-- are assigned to "gsm7324", "gsm7312, "fsm7326p", and "gsm7224". For the one using
+-- generic MIB, the new OIDs are has a "i" in the end.
+--
+gsm7312i OBJECT IDENTIFIER ::= { l3switch 5 }
+gsm7324i OBJECT IDENTIFIER ::= { l3switch 6 }
+fsm7326pi OBJECT IDENTIFIER ::= { l3switch 7 }
+
+gsm7248 OBJECT IDENTIFIER ::= { l2switch 1 }
+gsm7212 OBJECT IDENTIFIER ::= { l2switch 2 }
+gsm7224i OBJECT IDENTIFIER ::= { l2switch 3 }
+fsm7226 OBJECT IDENTIFIER ::= { l2switch 4 }
+
+gcm9000 OBJECT IDENTIFIER ::= { chassisswitch 1 }
+xcm8903 OBJECT IDENTIFIER ::= { chassisswitch 6 }
+
+---
+--- new SNMP-enabled smartswitch
+---
+gs748t OBJECT IDENTIFIER ::= { smartswitch 1 }
+fs726t OBJECT IDENTIFIER ::= { smartswitch 2 }
+gs716t OBJECT IDENTIFIER ::= { smartswitch 3 }
+fs750t OBJECT IDENTIFIER ::= { smartswitch 4 }
+gs724t OBJECT IDENTIFIER ::= { smartswitch 5 }
+fs726tp OBJECT IDENTIFIER ::= { smartswitch 6 }
+fs728tp OBJECT IDENTIFIER ::= { smartswitch 7 }
+gs108t OBJECT IDENTIFIER ::= { smartswitch 8 }
+gs108tp OBJECT IDENTIFIER ::= { smartswitch 9 }
+gs724tp OBJECT IDENTIFIER ::= { smartswitch 10 }
+gs748tp OBJECT IDENTIFIER ::= { smartswitch 11 }
+gs724tr OBJECT IDENTIFIER ::= { smartswitch 12 }
+gs748tr OBJECT IDENTIFIER ::= { smartswitch 13 }
+gs716tv2 OBJECT IDENTIFIER ::= { smartswitch 16 }
+gs724tv3 OBJECT IDENTIFIER ::= { smartswitch 17 }
+gs108tv2 OBJECT IDENTIFIER ::= { smartswitch 18 }
+gs110tp OBJECT IDENTIFIER ::= { smartswitch 19 }
+fs728tpv2 OBJECT IDENTIFIER ::= { smartswitch 20 }
+gs716tv3 OBJECT IDENTIFIER ::= { smartswitch 31 }
+gs724tv4 OBJECT IDENTIFIER ::= { smartswitch 32 }
+gs748tv5 OBJECT IDENTIFIER ::= { smartswitch 33 }
+xs712t OBJECT IDENTIFIER ::= { smartswitch 30 }
+
+
+fs728ts OBJECT IDENTIFIER ::= { stacksmartswitch 1 }
+fs752ts OBJECT IDENTIFIER ::= { stacksmartswitch 2 }
+fs752tps OBJECT IDENTIFIER ::= { stacksmartswitch 3 }
+gs724ts OBJECT IDENTIFIER ::= { stacksmartswitch 4 }
+gs748ts OBJECT IDENTIFIER ::= { stacksmartswitch 5 }
+gs752ts OBJECT IDENTIFIER ::= { stacksmartswitch 12 }
+gs728ts OBJECT IDENTIFIER ::= { stacksmartswitch 11 }
+gs752tstps OBJECT IDENTIFIER ::= { stacksmartswitch 8 }
+gs728tps OBJECT IDENTIFIER ::= { stacksmartswitch 13 }
+gs752tps OBJECT IDENTIFIER ::= { stacksmartswitch 14 }
+gs752txs OBJECT IDENTIFIER ::= { stacksmartswitch 10 }
+gs728txs OBJECT IDENTIFIER ::= { stacksmartswitch 15 }
+s3300-28x OBJECT IDENTIFIER ::= { stacksmartswitch 16 }
+s3300-28x-poe OBJECT IDENTIFIER ::= { stacksmartswitch 17 }
+s3300-52x OBJECT IDENTIFIER ::= { stacksmartswitch 18 }
+s3300-52x-poe OBJECT IDENTIFIER ::= { stacksmartswitch 19 }
+
+---
+--- new SNMP-enabled business router/firewall
+---
+fvx538 OBJECT IDENTIFIER ::= { router 1 }
+fvs338 OBJECT IDENTIFIER ::= { router 2 }
+fvg318 OBJECT IDENTIFIER ::= { router 3 }
+fvs336g OBJECT IDENTIFIER ::= { router 4 }
+
+---
+--- new SNMP-enabled firewall
+---
+fwag114 OBJECT IDENTIFIER ::= { firewall 3 }
+fvs124g OBJECT IDENTIFIER ::= { firewall 4 }
+fvs318v3 OBJECT IDENTIFIER ::= { firewall 5 }
+dgfv338 OBJECT IDENTIFIER ::= { firewall 6 }
+
+---
+--- new SNMP-enabled AP
+---
+wpn802 OBJECT IDENTIFIER ::= { accesspoint 1 }
+wg312 OBJECT IDENTIFIER ::= { accesspoint 2 }
+wag312 OBJECT IDENTIFIER ::= { accesspoint 3 }
+
+---
+--- new WLAN
+---
+
+-- New Textual Conventions
+AgentPortMask ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "Each octet within this value specifies a set of eight
+ ports, with the first octet specifying ports 1 through
+ 8, the second octet specifying ports 9 through 16, etc.
+ Within each octet, the most significant bit represents
+ the lowest numbered port, and the least significant bit
+ represents the highest numbered port. Thus, each port
+ of the bridge is represented by a single bit within the
+ value of this object. If that bit has a value of '1'
+ then that port is included in the set of ports; the port
+ is not included if its bit has a value of '0'
+
+ When setting this value, the system will ignore
+ configuration for ports not between the first and last
+ valid ports. Configuration of any port numbers between
+ this range that are not valid ports return a failure
+ message, but will still apply configuration for valid
+ ports."
+ SYNTAX OCTET STRING
+
+
+END