summaryrefslogtreecommitdiff
path: root/MIBS/procera/PACKETLOGIC-HW-SFP-MIB
diff options
context:
space:
mode:
authorDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
committerDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
commit98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch)
tree9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/procera/PACKETLOGIC-HW-SFP-MIB
downloadmibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.tar.gz
mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.zip
Initial commitHEADmain
Diffstat (limited to 'MIBS/procera/PACKETLOGIC-HW-SFP-MIB')
-rw-r--r--MIBS/procera/PACKETLOGIC-HW-SFP-MIB151
1 files changed, 151 insertions, 0 deletions
diff --git a/MIBS/procera/PACKETLOGIC-HW-SFP-MIB b/MIBS/procera/PACKETLOGIC-HW-SFP-MIB
new file mode 100644
index 0000000..7a2e20c
--- /dev/null
+++ b/MIBS/procera/PACKETLOGIC-HW-SFP-MIB
@@ -0,0 +1,151 @@
+PACKETLOGIC-HW-SFP-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ NOTIFICATION-TYPE,
+ MODULE-IDENTITY, OBJECT-TYPE, Integer32, Counter64,
+ Unsigned32, TimeTicks FROM SNMPv2-SMI
+ packetlogic2 FROM PACKETLOGIC-MIB
+ hw FROM PACKETLOGIC-HW-MIB
+ DisplayString, DateAndTime FROM SNMPv2-TC
+ CounterBasedGauge64 FROM HCNUM-TC;
+
+sfp MODULE-IDENTITY
+ LAST-UPDATED "201909121500Z"
+ ORGANIZATION "Procera Networks, Inc."
+ CONTACT-INFO "support@proceranetworks.com"
+ DESCRIPTION "MIB For SFP and SFP+ Optical Transceivers"
+ REVISION "201909121500Z"
+ DESCRIPTION " Latest version at the revision date for version GET VERSION HERE"
+
+ ::={hw 4}
+
+PortEntry ::= SEQUENCE {
+ portName DisplayString,
+ portCompatibility DisplayString,
+ portVendorName DisplayString,
+ portVendorOUI DisplayString,
+ portVendorPN DisplayString,
+ portVendorRevisionLevel DisplayString,
+ checksumBaseFields DisplayString,
+ portVendorSN DisplayString,
+ portVendorDateCode DisplayString,
+ checksumExtendedFields DisplayString,
+ portEntryIndex Integer32
+}
+
+ports OBJECT-TYPE
+ SYNTAX SEQUENCE OF PortEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Conceptual Table"
+ ::= {sfp 1}
+
+portEntry OBJECT-TYPE
+ SYNTAX PortEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Conceptual Table"
+ INDEX { portEntryIndex }
+ ::= {ports 1}
+
+portEntryIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..2147483647)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Unique Row Index for Conceptual Table"
+ ::={portEntry 999}
+
+
+
+
+
+
+
+
+
+
+
+
+portName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Port Name"
+
+ ::={portEntry 1}
+
+portCompatibility OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Electronic or optical compatibility"
+
+ ::={portEntry 2}
+
+portVendorName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "SFP vendor name"
+
+ ::={portEntry 3}
+
+portVendorOUI OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "SFP vendor IEEE company ID"
+
+ ::={portEntry 4}
+
+portVendorPN OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Part number provided by SFP vendor"
+
+ ::={portEntry 5}
+
+portVendorRevisionLevel OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Revision level for part number provided by vendor"
+
+ ::={portEntry 6}
+
+checksumBaseFields OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Check code for Base ID Fields"
+
+ ::={portEntry 7}
+
+portVendorSN OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Serial number provided by vendor"
+
+ ::={portEntry 8}
+
+portVendorDateCode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Vendor manufacturing date code"
+
+ ::={portEntry 9}
+
+checksumExtendedFields OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Check code for the Extended ID Fields"
+
+ ::={portEntry 10}
+
+
+
+END