summaryrefslogtreecommitdiff
path: root/MIBS/peplink/CELLULAR
diff options
context:
space:
mode:
authorDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
committerDavid Leutgeb <david.leutgeb@mannundmouse.com>2023-12-05 12:25:34 +0100
commit98a672123c7872f6b9b75a9a2b6bb3aea504de6a (patch)
tree9b13bd7f563c3198047bd359195327cf28b3caf0 /MIBS/peplink/CELLULAR
downloadmibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.tar.gz
mibs-98a672123c7872f6b9b75a9a2b6bb3aea504de6a.zip
Initial commitHEADmain
Diffstat (limited to 'MIBS/peplink/CELLULAR')
-rw-r--r--MIBS/peplink/CELLULAR269
1 files changed, 269 insertions, 0 deletions
diff --git a/MIBS/peplink/CELLULAR b/MIBS/peplink/CELLULAR
new file mode 100644
index 0000000..b67c9a0
--- /dev/null
+++ b/MIBS/peplink/CELLULAR
@@ -0,0 +1,269 @@
+-- ********************************************************************
+ CELLULAR DEFINITIONS ::= BEGIN
+
+ IMPORTS
+ OBJECT-GROUP
+ FROM SNMPv2-CONF
+ enterprises, Integer32, IpAddress,Unsigned32, Counter64, OBJECT-TYPE, MODULE-IDENTITY
+ FROM SNMPv2-SMI
+ DisplayString, RowStatus, TruthValue, MacAddress
+ FROM SNMPv2-TC;
+
+--
+-- Node definitions
+--
+-- ********************************************************************
+-- * MODULE IDENTITY
+-- ********************************************************************
+-- The Enterprises Number
+ peplink OBJECT IDENTIFIER ::= { enterprises 23695 }
+
+ productMib OBJECT IDENTIFIER ::= { peplink 200 }
+
+ generalMib OBJECT IDENTIFIER ::= { productMib 1 }
+
+ cellularMib MODULE-IDENTITY
+ LAST-UPDATED "201805071200Z" -- 05 07, 2018 at 12:00 GMT
+ ORGANIZATION "PEPLINK"
+ CONTACT-INFO ""
+ DESCRIPTION
+ "MIB module for CELLULAR."
+ ::= { generalMib 12 }
+
+-- #####################################################################
+--
+-- **********************************************************************
+-- * MIB attribute OBJECT-TYPE definitions follow
+-- **********************************************************************
+ cellularSignalInfo OBJECT IDENTIFIER ::= { cellularMib 1 }
+
+-- **********************************************************************
+-- * Table
+-- **********************************************************************
+ cellularSignalInfoTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CellularSignalInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cellular signal info table"
+ ::= { cellularSignalInfo 1 }
+
+ cellularSignalInfoEntry OBJECT-TYPE
+ SYNTAX CellularSignalInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in the cellularSignalInfoTable"
+ INDEX { cellularSignalInfoId }
+ ::= { cellularSignalInfoTable 1 }
+
+ CellularSignalInfoEntry ::=
+ SEQUENCE {
+ cellularSignalInfoId
+ Integer32,
+ cellularSignalInfoWanId
+ Integer32,
+ cellularSignalRssi
+ Integer32,
+ cellularSignalSnr
+ Integer32,
+ cellularSignalSinr
+ Integer32,
+ cellularSignalEcio
+ Integer32,
+ cellularSignalRsrp
+ Integer32,
+ cellularSignalRsrq
+ Integer32,
+ cellularNetworkType
+ OCTET STRING,
+ cellularBand
+ OCTET STRING,
+ cellularLac
+ Integer32,
+ cellularTac
+ Integer32,
+ cellularENodeBId
+ Integer32
+ }
+
+ cellularSignalInfoId OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cellular signal info ID."
+ ::= { cellularSignalInfoEntry 1 }
+
+ cellularSignalInfoWanId OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cellular signal info WAN ID."
+ ::= { cellularSignalInfoEntry 2 }
+
+ cellularSignalRssi OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "dBm"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cellular RSSI (units: dBm).
+ Remark:
+ If the value equals -9999, means signal strength
+ not applicable in this cellular."
+ ::= { cellularSignalInfoEntry 3 }
+
+ cellularSignalSnr OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "dB"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cellular SNR (units: dB).
+ Remark:
+ If the value equals -9999, means signal strength
+ not applicable in this cellular."
+ ::= { cellularSignalInfoEntry 4 }
+
+ cellularSignalSinr OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "dB"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cellular SINR (units: dB).
+ Remark:
+ If the value equals -9999, means signal strength
+ not applicable in this cellular."
+ ::= { cellularSignalInfoEntry 5 }
+
+ cellularSignalEcio OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "dB"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cellular Ec/Io (units: dB).
+ Remark:
+ If the value equals -9999, means signal strength
+ not applicable in this cellular."
+ ::= { cellularSignalInfoEntry 6 }
+
+ cellularSignalRsrp OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "dBm"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cellular RSRP (units: dBm).
+ Remark:
+ If the value equals -9999, means signal strength
+ not applicable in this cellular."
+ ::= { cellularSignalInfoEntry 7 }
+
+ cellularSignalRsrq OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "dB"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cellular RSRQ (units: dB).
+ Remark:
+ If the value equals -9999, means signal strength
+ not applicable in this cellular."
+ ::= { cellularSignalInfoEntry 8 }
+
+ cellularNetworkType OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cellular Network Type."
+ ::= { cellularSignalInfoEntry 9 }
+
+ cellularBand OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cellular Band."
+ ::= { cellularSignalInfoEntry 10 }
+
+ cellularLac OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cellular Location Area Code(LAC).
+ Remark:
+ If the value equals -1, means LAC not applicable in this cellular."
+ ::= { cellularSignalInfoEntry 11 }
+
+ cellularTac OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cellular Tracking Area Code(TAC).
+ Remark:
+ If the value equals -1, means TAC not applicable in this cellular."
+ ::= { cellularSignalInfoEntry 12 }
+
+ cellularENodeBId OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cellular eNodeB ID.
+ Remark:
+ If the value equals -1, means eNodeB ID not applicable in this cellular."
+ ::= { cellularSignalInfoEntry 13 }
+
+ cellularIdentityInfo OBJECT IDENTIFIER ::= { cellularMib 2 }
+
+-- **********************************************************************
+-- * Table
+-- **********************************************************************
+ cellularIdentityInfoTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CellularIdentityInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Cellular identity info table"
+ ::= { cellularIdentityInfo 1 }
+
+ cellularIdentityInfoEntry OBJECT-TYPE
+ SYNTAX CellularIdentityInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in the cellularIdentityInfoTable"
+ INDEX { cellularIdentityInfoId }
+ ::= { cellularIdentityInfoTable 1 }
+
+ CellularIdentityInfoEntry ::=
+ SEQUENCE {
+ cellularIdentityInfoId
+ Integer32,
+ cellularIdentityInfoImei
+ OCTET STRING
+ }
+
+ cellularIdentityInfoId OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cellular identity ID."
+ ::= { cellularIdentityInfoEntry 1 }
+
+ cellularIdentityInfoImei OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Cellular IMEI."
+ ::= { cellularIdentityInfoEntry 2 }
+END