diff --git a/MIBS/pegasus/PEGASUS-SDH-MIB b/MIBS/pegasus/PEGASUS-SDH-MIB new file mode 100644 index 0000000..69eb213 --- /dev/null +++ b/MIBS/pegasus/PEGASUS-SDH-MIB @@ -0,0 +1,968 @@ +PEGASUS-SDH-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ Integer32,
+ OBJECT-TYPE,
+ MODULE-IDENTITY FROM SNMPv2-SMI
+ TEXTUAL-CONVENTION,
+ DisplayString,
+ TruthValue FROM SNMPv2-TC
+ InterfaceIndex,
+ InterfaceIndexOrZero,
+ ifIndex FROM IF-MIB
+ pegasusMibModule,
+ OperStateEnum,
+ AvailabilityStatusElem,
+ CommStateEnum FROM PEGASUS-MIB;
+
+pegasusSdhMibModule MODULE-IDENTITY
+ LAST-UPDATED "200403180000Z" -- 18 March, 2004
+ ORGANIZATION "Schmid Telecom, Zurich"
+ CONTACT-INFO
+ "Schmid Telecom AG
+ Binzstrasse 35, CH-8048 Zurich
+ Switzerland
+
+ Email: xdslsupport@schmid-telecom.ch"
+ DESCRIPTION
+ "This MIB applies to the PEGASUS SDSL product manufactured by Schmid
+ Telecom Zurich. The MIB is modelled after the PEM management model, so
+ object hierarchy and individual variables agree with the PEM client. This
+ MIB represents an extension to the DS1-MIB and the SONET-MIB. These three
+ MIB files are used to manage the PEGASUS STM-1 card.
+
+ The PEGASUS-SDH-MIB contains five tables:
+ - stm1CardTable one entry for each STM-1 card configured.
+ - stm1CardClockTable one entry for each STM-1 card configured.
+ - ethernetIfTable one entry for each Ethernet interface of a
+ configured STM-1 card.
+ - vcTable one entry for each Virtual Container (VC-3/4/12).
+ - tugConfigTable one entry for each Tributary Unit Group (TUG-3).
+
+ Note
+ - The tables that represent extensions to the DS1-/SINET-MIB use the
+ ifIndex from IF-MIB (ifTable)."
+
+ REVISION "200403180000Z" -- 18 March, 2004
+ DESCRIPTION
+ "Improved Alarm signalisation. A new variable stm1CardAlarmStatus shows
+ the alarms that are active on the STM-1 card. Active Ethernet alarms are
+ shown by ethernetIfAlarmStatus. The following values for vcAlarmStatus
+ are can not occur (not used):
+ - vcgTxAddTimeout - vcgDnuOk
+ - vcgTxAdd - vcgRxAdd
+ - vcgTxRemove - vcgRxRemove
+ - vcgTxDnu - vcgRxFail"
+ REVISION "200401070000Z" -- 7 January, 2004
+ DESCRIPTION
+ "Actually, only GFP is supported as Ethernet Encapsulation. Therefore
+ the variable etherIfEncapsulation is now read-only."
+ REVISION "200311170000Z" -- 17 November, 2003
+ DESCRIPTION
+ "Initial Revision."
+ ::= { pegasusMibModule 8 }
+
+
+-- *******************************************************************
+-- stm1 card group
+--
+-- This group contains four tables:
+-- - stm1CardTable
+-- - ethernetIfTable
+-- - vcConfigTable
+-- - tugConfigTable
+-- *******************************************************************
+-- STM1 Card Enumerations and Subranges
+
+ClockSourceEnum ::= INTEGER {
+ rxLineClock(1),
+ referenceClock(2),
+ freeRun(3)
+ }
+
+ClockSyncStateEnum ::= INTEGER {
+ syncOk(1),
+ syncNotOk(2)
+ }
+
+ClockModeEnum ::= INTEGER {
+ enabled(1),
+ disabled(2)
+ }
+
+ClockPriorityEnum ::= INTEGER {
+ primary(1),
+ secondary(2)
+ }
+
+ClockQualityEnum ::= INTEGER {
+ prc(1),
+ ssu-a(2),
+ ssu-b(3),
+ sec(4),
+ dnu(5),
+ auto(6),
+ unknown(7)
+ }
+
+ClockStateEnum ::= INTEGER {
+ invalid(1),
+ valid(2)
+ }
+
+MultiplexingModeEnum ::= INTEGER {
+ au3(1),
+ au4(2)
+ }
+
+VirtualContainerTypeEnum ::= INTEGER {
+ vc4(1),
+ vc3(2),
+ vc12(3)
+ }
+
+LaserOperationModeEnum ::= INTEGER {
+ off(1),
+ als(2)
+ }
+
+LaserStateEnum ::= INTEGER {
+ on(1),
+ shutdown(2),
+ restart(3)
+ }
+
+SdhInterfaceEnum ::= INTEGER {
+ optical(1),
+ e1(2)
+ }
+
+PRBSPatternEnum ::= INTEGER {
+ pattern2exp15(1), -- 2^15-1 = 32767
+ pattern2exp20(2) -- 2^20-1 = 1048575
+ }
+
+TraceSizeEnum ::= INTEGER {
+ size1byte(1),
+ size16byte(2)
+ }
+
+SignalLabel ::= TEXTUAL-CONVENTION
+ DISPLAY-HINT "x"
+ STATUS current
+ DESCRIPTION
+ "Representation of a VC Signal Label. The meaning of the SignalLabel
+ depends on the type of vitual container.
+ VC-12s use the following values:
+ 001b Unequipped
+ 001b Equipped (non specific)
+ 010b Asynchronous
+ 011b Bit Synchronous
+ 100b Byte Synchronous
+ 101b Reserved for future use
+ 110b Test signal (O.181)
+ 111b VC-AIS
+
+ VC-4 and VC-3 use these values:
+ 00h Unequipped or supervisory-unequipped
+ 01h Equipped - non-specific
+ 02h TUG Structure
+ 03h Locked TU-n
+ 04h Asynch. mapping of 34'386/44'736 kbit/s into Container-3
+ 12h Asynch. mapping of 139'264 kbit/s into Container-4
+ 13h ATM Mapping
+ 14h MAN DQDB (IEEE 802.6 mapping
+ 15h FDDI (ISO 9314) mapping
+ 16h Mapping of HDLC/PPP framed signal
+ 17h Mapping of SDL with SDH self synch. Scrambler
+ 18h Mapping of HDLC/LAP-S framed signals
+ 19h Mapping of SDL with set-reset scrambler
+ 1Ah Mapping of 10 Gbit/s Ethernet frames (IEEE 802.3)
+ CFh Obsolete mapping of HDLC/PPP framed signal
+ E1h-FCh Reserved for national use
+ FEh Test signal, O.181 specific mapping
+ FFh VC-AIS"
+ SYNTAX INTEGER(0..7|18..26|207|225..252|254..255)
+
+ConcatenationTypeEnum ::= INTEGER {
+ lcas(1),
+ nonLCAS(2)
+ }
+
+EthernetIfEncapsulationEnum ::= INTEGER {
+ disabled(1), -- not supported feature
+ gfp(2),
+ lapf(3), -- not supported feature
+ laps(4), -- not supported feature
+ ppp(5) -- not supported feature
+ }
+
+OrderLevelEnum ::= INTEGER {
+ highOrder(1),
+ lowOrder(2)
+ }
+
+STM1SlotNumber ::= INTEGER(2)
+TUGIndex ::= INTEGER(1..3)
+TUGIndexOrZero ::= INTEGER(0..3)
+
+-- STM-1 Card: STM-1 Card Table
+
+stm1CardTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Stm1CardEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table containing stm1 card specific information."
+ ::= { pegasusSdhMibModule 1 }
+
+stm1CardEntry OBJECT-TYPE
+ SYNTAX Stm1CardEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Row and index definition for stm1 card table."
+ INDEX { stm1CardSlotNumber }
+ ::= { stm1CardTable 1 }
+
+Stm1CardEntry ::= SEQUENCE {
+ stm1CardSlotNumber STM1SlotNumber,
+ -- identification
+ stm1CardName DisplayString,
+ stm1CardHardwareVersion DisplayString,
+ stm1CardFirmwareVersion DisplayString,
+ stm1CardManufacturer DisplayString,
+ stm1CardSerialNumber DisplayString,
+ -- configuration
+ stm1CardMultiplexingMode MultiplexingModeEnum,
+ stm1CardJ0TraceMonitoring OperStateEnum,
+ stm1CardJ1TraceMonitoring OperStateEnum,
+ stm1CardJ2TraceMonitoring OperStateEnum,
+ stm1CardJ0PathTraceSize TraceSizeEnum,
+ stm1CardJ0PathTraceSend DisplayString, -- same as sonetMediumCircuitIdentifier
+ stm1CardJ0PathTraceExpected DisplayString,
+ stm1CardJ0PathTraceReceive DisplayString,
+ stm1CardLaserOperationMode LaserOperationModeEnum,
+ stm1CardLaserState LaserStateEnum,
+ -- supervision
+ stm1CardOperState OperStateEnum,
+ stm1CardAvailabilityState AvailabilityStatusElem,
+ stm1CardMgmtCommState CommStateEnum,
+ -- maintenance
+ stm1CardPRBSGeneratorSink SdhInterfaceEnum,
+ stm1CardPRBSAnalyzerSource SdhInterfaceEnum,
+ stm1CardPRBSPattern PRBSPatternEnum,
+ -- additional card alarm status
+ stm1CardAlarmStatus Integer32
+ }
+
+stm1CardSlotNumber OBJECT-TYPE
+ SYNTAX STM1SlotNumber
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Slot number for stm1 card."
+ ::= { stm1CardEntry 1 }
+
+stm1CardName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Name of the PEGASUS device."
+ ::= { stm1CardEntry 2 }
+
+stm1CardHardwareVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Hardware version of the STM-1 card. This is also called CHM-number
+ (it always starts with the letters 'CHM'). The number '404' after
+ 'CHM' identifies the card as a STM-1 card."
+ ::= { stm1CardEntry 3 }
+
+stm1CardFirmwareVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Version number and build date of the firmware running on the line
+ card. The format is 'major.minor YYYYMMDD hh:mm'."
+ ::= { stm1CardEntry 4 }
+
+stm1CardManufacturer OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Manufacturer of the STM-1 card."
+ ::= { stm1CardEntry 5 }
+
+stm1CardSerialNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Serial number of the line card. Also called HM-number, as it always
+ starts with 'HM'. Example: HMVSS014810294."
+ ::= { stm1CardEntry 6 }
+
+stm1CardMultiplexingMode OBJECT-TYPE
+ SYNTAX MultiplexingModeEnum
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Selects the SDH multiplexing mode. Either it is STM1-AU3-VC3 or
+ STM1-AU4-VC4."
+ ::= { stm1CardEntry 7 }
+
+stm1CardJ0TraceMonitoring OBJECT-TYPE
+ SYNTAX OperStateEnum
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "If trace monitoring is disable no alarm is propagated to PEM and
+ also no RDI/AIS is inserted."
+ ::= { stm1CardEntry 8 }
+
+stm1CardJ1TraceMonitoring OBJECT-TYPE
+ SYNTAX OperStateEnum
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "If trace monitoring is disable no alarm is propagated to PEM and
+ also no RDI/AIS is inserted."
+ ::= { stm1CardEntry 9 }
+
+stm1CardJ2TraceMonitoring OBJECT-TYPE
+ SYNTAX OperStateEnum
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "If trace monitoring is disable no alarm is propagated to PEM and
+ also no RDI/AIS is inserted."
+ ::= { stm1CardEntry 10 }
+
+stm1CardJ0PathTraceSize OBJECT-TYPE
+ SYNTAX TraceSizeEnum
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Size of the Regenerator Section Trace Message."
+ ::= { stm1CardEntry 11 }
+
+stm1CardJ0PathTraceSend OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Configurable Regenerator Section (RS) Trace Message."
+ ::= { stm1CardEntry 12 }
+
+stm1CardJ0PathTraceExpected OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Regenerator Section (RS) Trace Message that should be received."
+ ::= { stm1CardEntry 13 }
+
+stm1CardJ0PathTraceReceive OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Regenerator Section (RS) Trace Message that is be received."
+ ::= { stm1CardEntry 14 }
+
+stm1CardLaserOperationMode OBJECT-TYPE
+ SYNTAX LaserOperationModeEnum
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Configuration of the 'Automatic Laser Shutdown' feature."
+ ::= { stm1CardEntry 15 }
+
+stm1CardLaserState OBJECT-TYPE
+ SYNTAX LaserStateEnum
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Actual state of the laser."
+ ::= { stm1CardEntry 16 }
+
+stm1CardOperState OBJECT-TYPE
+ SYNTAX OperStateEnum
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The operational state is a status property indicating whether or
+ not a device is physically installed and working.
+ enabled The device is partially or fully operable and available
+ for use.
+ disabled The device is totally inoperable and unavailable to provide
+ service."
+ ::= { stm1CardEntry 17 }
+
+stm1CardAvailabilityState OBJECT-TYPE
+ SYNTAX AvailabilityStatusElem
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The availability status gives more detailed information about
+ failures within a device. An empty status set means that no error
+ exists. Possible status are:
+ in test The device is under test.
+ failed The device has an internal fault that prevents it from
+ operating.
+ power off The device requires power to be applied and is not
+ powered on.
+ off line The device requires a routine operation to be performed
+ to place it online and make it available for use.
+ off duty The device has been made inactive by an internal control
+ process in accordance with a predetermined time
+ schedule.
+ dependency The device can not operate because some other resource
+ on which it depends is unavailable.
+ degraded The device is partially defective but still operable.
+ not installed The device is not present, or incomplete.
+ log full The log is full."
+ ::= { stm1CardEntry 18 }
+
+stm1CardMgmtCommState OBJECT-TYPE
+ SYNTAX CommStateEnum
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The Management Comm State indicates the state of the management
+ connection between the PEM Server and the STM-1 card.
+ disconnected No connection has been established.
+ init A connection has freshly been established on
+ the underlying protocol, but no management
+ information has been transmitted so far.
+ identification The connected device is being identified.
+ check hardware The connected hardware is compared to the one
+ stored in the configuration.
+ hardware adaptation If the configured and the existing device do
+ not match, an adoption is made. The behaviour
+ in this case can be configured with the 'HW
+ Adaptation Policy' option.
+ check program version The program version of the connected hardware
+ is compared to the one stored in the
+ configuration.
+ check config version The configuration version of the connected
+ hardware is compared to the one stored in the
+ configuration.
+ download config If a configuration version mismatch has been
+ detected and the 'Config Priority' of 'PEGASUS
+ system' is set to 'Device', the configuration
+ is downloaded from the device to the PEM
+ Server.
+ upload config If a configuration version mismatch has been
+ detected and the 'Config Priority' of 'PEGASUS
+ system' is set to 'Server', the configuration
+ is uploaded from the PEM Server to the device.
+ status synch The values of the status properties are being
+ synchronised.
+ resetting The device is resetting.
+ inactive The device is connected, but it is inactive,
+ that is not operational. This may be due to a
+ hardware mismatch.
+ active The management connection between the device
+ and the PEM Server is fully established and
+ the device is active."
+ ::= { stm1CardEntry 19 }
+
+stm1CardPRBSGeneratorSink OBJECT-TYPE
+ SYNTAX SdhInterfaceEnum
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Determines, whether the PRBS Generator should be used on the
+ optical or on the E1 links."
+ ::= { stm1CardEntry 20 }
+
+stm1CardPRBSAnalyzerSource OBJECT-TYPE
+ SYNTAX SdhInterfaceEnum
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Determines, whether the PRBS Analyzer should be used on the
+ optical or on the E1 links."
+ ::= { stm1CardEntry 21 }
+
+stm1CardPRBSPattern OBJECT-TYPE
+ SYNTAX PRBSPatternEnum
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Determines the PRBS Pattern to be used."
+ ::= { stm1CardEntry 22 }
+
+stm1CardAlarmStatus OBJECT-TYPE
+ SYNTAX Integer32 (1..511)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This variable indicates the status of STM-1 card, regenerator
+ section and multiplex section. It's a bitmap represented as a sum.
+ Therefore multiple alarms can be displayed simultaneously. The value
+ noAlarm is only set if there isn't any alarm active.
+ The various bit positions are:
+ 1 No alarm present
+ -- STM-1 card --
+ 2 Initialization failure
+ 4 Firmware Version Mismatch
+ 8 Maintenance
+ -- regenerator section RS --
+ 16 Loss of Signal (LOS)
+ 32 Loss of Frame (LOF)
+ 64 Trace ID Mismatch (RS-TIM)
+ -- multiplex section MS --
+ 128 Alarm Indication Signal (MS-AIS)
+ 256 Remote Defect Indication (MS-RDI, former FERF)"
+ ::= { stm1CardEntry 23 }
+
+-- STM-1 Card: STM-1 Card Clock Table
+
+stm1CardClockTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Stm1CardClockEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table containing stm1 card specific clock information."
+ ::= { pegasusSdhMibModule 2 }
+
+stm1CardClockEntry OBJECT-TYPE
+ SYNTAX Stm1CardClockEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Row and index definition for stm1 card clock table."
+ INDEX { stm1CardSlotNumber }
+ ::= { stm1CardClockTable 1 }
+
+Stm1CardClockEntry ::= SEQUENCE {
+ -- clock settings
+ stm1CardActiveClockSource ClockSourceEnum,
+ stm1CardClockSyncState ClockSyncStateEnum,
+ stm1CardTxLineClockQuality ClockQualityEnum,
+ stm1CardRxClockMode ClockModeEnum,
+ stm1CardRxClockPriority ClockPriorityEnum,
+ stm1CardRxClockQuality ClockQualityEnum,
+ stm1CardRxClockState ClockStateEnum,
+ stm1CardReferenceClockMode ClockModeEnum,
+ stm1CardReferenceClockPriority ClockPriorityEnum,
+ stm1CardReferenceClockQuality ClockQualityEnum,
+ stm1CardReferenceClockState ClockStateEnum
+ }
+
+stm1CardActiveClockSource OBJECT-TYPE
+ SYNTAX ClockSourceEnum
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Displays which clock sourceis active and used as sync source."
+ ::= { stm1CardClockEntry 1 }
+
+stm1CardClockSyncState OBJECT-TYPE
+ SYNTAX ClockSyncStateEnum
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Sync status is OK if RX or Reference clock is valid and used as
+ active sync source."
+ ::= { stm1CardClockEntry 2 }
+
+stm1CardTxLineClockQuality OBJECT-TYPE
+ SYNTAX ClockQualityEnum
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This is the clock quality of the outgoing SDH signal. The default
+ sets the outgoing quality to the incoming quality. Sometime it may
+ be useful to set a fix outgoing quality."
+ ::= { stm1CardClockEntry 3 }
+
+stm1CardRxClockMode OBJECT-TYPE
+ SYNTAX ClockModeEnum
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "If enabled the RX line clock can be used as sync source."
+ ::= { stm1CardClockEntry 4 }
+
+stm1CardRxClockPriority OBJECT-TYPE
+ SYNTAX ClockPriorityEnum
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This value has always the opposite value of Reference Clock
+ Priority."
+ ::= { stm1CardClockEntry 5 }
+
+stm1CardRxClockQuality OBJECT-TYPE
+ SYNTAX ClockQualityEnum
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This is the clock quality of the incoming SDH signal."
+ ::= { stm1CardClockEntry 6 }
+
+stm1CardRxClockState OBJECT-TYPE
+ SYNTAX ClockStateEnum
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Clock status is valid if a good clock can be found on input
+ (clock checker)."
+ ::= { stm1CardClockEntry 7 }
+
+stm1CardReferenceClockMode OBJECT-TYPE
+ SYNTAX ClockModeEnum
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "If enabled the Reference clock (V5 card input) can be used as sync
+ source."
+ ::= { stm1CardClockEntry 8 }
+
+stm1CardReferenceClockPriority OBJECT-TYPE
+ SYNTAX ClockPriorityEnum
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This value has always the opposite value of Rx Clock Priority."
+ ::= { stm1CardClockEntry 9 }
+
+stm1CardReferenceClockQuality OBJECT-TYPE
+ SYNTAX ClockQualityEnum
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Defines the quality of the reference clock input. This value will
+ be transmitted in SDH-TX if reference clock is used as active sync
+ source."
+ ::= { stm1CardClockEntry 10 }
+
+stm1CardReferenceClockState OBJECT-TYPE
+ SYNTAX ClockStateEnum
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Clock status is valid if a good clock can be found on input
+ (clock checker)."
+ ::= { stm1CardClockEntry 11 }
+
+
+-- STM-1 Card: Ethernet Interface Table
+
+ethernetIfTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EthernetIfEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table contains additional information concerning the ethernet
+ interfaces of a STM-1 card. It represents an extension of the
+ if(X)Table (see IF-MIB)."
+ ::= { pegasusSdhMibModule 3 }
+
+ethernetIfEntry OBJECT-TYPE
+ SYNTAX EthernetIfEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Row and index definition for the ethernetIfTable."
+ INDEX { ifIndex }
+ ::= { ethernetIfTable 1 }
+
+EthernetIfEntry ::= SEQUENCE {
+ etherIfConcatenationOption ConcatenationTypeEnum,
+ etherIfEncapsulation EthernetIfEncapsulationEnum,
+ etherIfOrderLevel OrderLevelEnum,
+ etherIfAlarmStatus Integer32
+ }
+
+etherIfConcatenationOption OBJECT-TYPE
+ SYNTAX ConcatenationTypeEnum
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Configuration of the Link Capacity Adjustment Scheme."
+ ::= { ethernetIfEntry 1 }
+
+etherIfEncapsulation OBJECT-TYPE
+ SYNTAX EthernetIfEncapsulationEnum
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This attribute shows the used Ethernet encapsulation protocol."
+ ::= { ethernetIfEntry 2 }
+
+etherIfOrderLevel OBJECT-TYPE
+ SYNTAX OrderLevelEnum
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Only relevant, if SDH Multiplexing Mode (see STM-1 card propertied)
+ is set to VC3."
+ ::= { ethernetIfEntry 3 }
+
+etherIfAlarmStatus OBJECT-TYPE
+ SYNTAX Integer32 (1..511)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This variable indicates the status of an Ethernet Interface. It's
+ a bitmap represented as a sum. Therefore multiple defects can be
+ displayed simultaneously. The value noAlarm is only set if there
+ isn't any alarm.
+ The various bit positions are (LO = LowOrder, HO = HighOrder):
+ 1 No alarm
+ 2 LO LCAS group identifier mismatch (Rx)
+ 4 HO LCAS group identifier mismatch (Rx)
+ 8 LO VCG exceeds max. differential delay (Rx)
+ 16 HO VCG exceeds max. differential delay (Rx)
+ 32 LO VCG exceeds max. differential delay, calculated over all
+ containers (Rx)
+ 64 HO VCG exceeds max. differential delay, calculated over all
+ containers (Rx)
+ 128 Transmit FIFO overflow (Tx)
+ 256 Rx head-of-line blocking FIFO overflow"
+ ::= { ethernetIfEntry 4 }
+
+-- STM-1 Card: Virtual Container (VC) Configuration Table
+
+vcTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF VcEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table contains additional information for VC concerning the
+ multiplexing configuration. It's an extension of the ifTable
+ (IF-MIB) and the tables of the SONET/SDH-MIB.
+ "
+ ::= { pegasusSdhMibModule 4 }
+
+vcEntry OBJECT-TYPE
+ SYNTAX VcEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Row and index definition for the vcConfigTable."
+ INDEX { ifIndex }
+ ::= { vcTable 1 }
+
+VcEntry ::= SEQUENCE {
+ vcType VirtualContainerTypeEnum,
+ vcRelatedTUG TUGIndexOrZero,
+ vcRelatedVC InterfaceIndexOrZero,
+ vcAssignedIfIndex InterfaceIndexOrZero,
+ vcPathTraceSend DisplayString, -- same as dsx1CircuitIdentifier
+ vcPathTraceExpected DisplayString,
+ vcPathTraceReceive DisplayString,
+ vcSignalLabelSend SignalLabel,
+ vcSignalLabelExpected SignalLabel,
+ vcSignalLabelReceive SignalLabel,
+ vcAlarmStatus Integer32
+ }
+
+vcType OBJECT-TYPE
+ SYNTAX VirtualContainerTypeEnum
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Type of Virtual Container (VC). In Pegasus VC-4, VC-3 or VC-12."
+ ::= { vcEntry 1 }
+
+vcRelatedTUG OBJECT-TYPE
+ SYNTAX TUGIndexOrZero
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Represents the index of the Tributary Unit Group within the
+ tugConfigTable to which this VC is assigned to. The value depends
+ also on the multiplexing mode. If the value is 0, there doesn't
+ exist the relation VC-x to TUG-3. Possible values:
+ 1) multiplexing mode = AU-4:
+ VC-4: vcRelatedTUG = 0
+ VC-3/12: vcRelatedTUG = 1..3
+ 2) multiplexing mode = AU-3:
+ vcRelatedTUG = 0 (no dependency on VC type)"
+ ::= { vcEntry 2 }
+
+vcRelatedVC OBJECT-TYPE
+ SYNTAX InterfaceIndexOrZero
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Represents the index of the Virtual Container within the
+ ifTable to which this VC is assigned to. The value depends
+ also on the multiplexing mode. If the value is 0, there doesn't
+ exist the relation VC-x to VC-x. Possible values:
+ 1) multiplexing mode = AU-4:
+ vcRelatedVC = 0 (no dependency on VC type)
+ 2) multiplexing mode = AU-3:
+ VC-3: vcRelatedVC = 0
+ VC-12: vcRelatedVC = 2031..2033 (example for slot 2)"
+ ::= { vcEntry 3 }
+
+vcAssignedIfIndex OBJECT-TYPE
+ SYNTAX InterfaceIndexOrZero
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Represents the index of the interface within the ifTable (IF-MIB)
+ that transmits to this VC."
+ ::= { vcEntry 4 }
+
+vcPathTraceSend OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The value of the outgoing J1 Byte VC Path Trace byte message."
+ ::= { vcEntry 5 }
+
+vcPathTraceExpected OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The value of the expected J1 Byte VC Path Trace byte message."
+ ::= { vcEntry 6 }
+
+vcPathTraceReceive OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value of the incoming J1 Byte VC Path Trace byte message."
+ ::= { vcEntry 7 }
+
+vcSignalLabelSend OBJECT-TYPE
+ SYNTAX SignalLabel
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The outgoing C2 VC Signal Label (0x02 = TUG structure)."
+ ::= { vcEntry 8 }
+
+vcSignalLabelExpected OBJECT-TYPE
+ SYNTAX SignalLabel
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The expected C2 VC Signal Label (0x02 = TUG structure)."
+ ::= { vcEntry 9 }
+
+vcSignalLabelReceive OBJECT-TYPE
+ SYNTAX SignalLabel
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The incoming C2 VC Signal Label (0x02 = TUG structure)."
+ ::= { vcEntry 10 }
+
+vcAlarmStatus OBJECT-TYPE
+ SYNTAX Integer32 (1..524287)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This variable indicates the status of the VC. It's a bitmap
+ represented as a sum. Therefore multiple defects can be displayed
+ simultaneously. The value noDefect should only be set if there is
+ no other defect. Some alarms can't occur actually.
+ The various bit positions are:
+ 1 vcNoDefect
+ 2 vcAlarmAIS
+ 4 vcAlarmLOP
+ 8 vcAlarmRDI
+ 16 vcAlarmUnequipped
+ 32 vcAlarmPLM
+ 64 vcAlarmTIM
+ 128 vcAlarmLOM
+ 256 vcAlarmRFI
+ 512 vcgTxAddTimeout -- not used (deprecated)
+ 1024 vcgTxAdd -- not used (deprecated)
+ 2048 vcgTxRemove -- not used (deprecated)
+ 4096 vcgTxDnu -- not used (deprecated)
+ 8192 vcgDnuOk -- not used (deprecated)
+ 16384 vcgRxAdd -- not used (deprecated)
+ 32768 vcgRxRemove -- not used (deprecated)
+ 65536 vcgRxFail -- not used (deprecated)
+ 131072 vcgLcasCrcError
+ 262144 vcgNonLcasSeqError"
+ ::= { vcEntry 11 }
+
+-- STM-1 Card: Tributary Unit Group (TUG) Configuration Table
+
+tugConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TugConfigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table contains information concerning Tributary Unit Groups.
+ If AU-3 structure is used, this table is empty."
+ ::= { pegasusSdhMibModule 5 }
+
+tugConfigEntry OBJECT-TYPE
+ SYNTAX TugConfigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Row and index definition for the tugConfigTable."
+ INDEX { tugIndex }
+ ::= { tugConfigTable 1 }
+
+TugConfigEntry ::= SEQUENCE {
+ tugIndex TUGIndex,
+ tugRelatedVC4 InterfaceIndex,
+ tugOrderLevel OrderLevelEnum
+ }
+
+tugIndex OBJECT-TYPE
+ SYNTAX TUGIndex
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Number of the TUG. Range 1..3"
+ ::= { tugConfigEntry 1 }
+
+tugRelatedVC4 OBJECT-TYPE
+ SYNTAX InterfaceIndex
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ ""
+ ::= { tugConfigEntry 2 }
+
+tugOrderLevel OBJECT-TYPE
+ SYNTAX OrderLevelEnum
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Individual Order Level of this TUG. If high order is used, the TUG
+ has exactly one VC-3 and no VC-12s. If low order is used, the TUG
+ has exactly 21 VC-12 and no VC-3."
+ ::= { tugConfigEntry 3 }
+
+
+-- STM-1 Support: Additional information
+
+sdhMibRevision OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The version number assigned by the version control system. You can query
+ this from the agent, to find out with which version of the MIB was built
+ into the agent. The value is also present in copies of the MIB to feed
+ into SNMP managers. Comparing the version numbers from both sources can
+ help to detect mismatches. The revision string for this version is:
+ $Workfile: PEGASUS-SDH-MIB.txt $ $Revision: 14 $ $Date: 3/18/04 6:40p $"
+ DEFVAL { "$Workfile: PEGASUS-SDH-MIB.txt $ $Revision: 14 $ $Date: 3/18/04 6:40p $" }
+ ::= { pegasusSdhMibModule 6 }
+
+END
|